Envelope Compliance Certificate
Project Information :��, Q.• •�� SF• •.;�
No 446
Energy Code: 2017 Florida Building Code, Energy Conservation f ;
Project Title: Popeyes Ft Pierce, F
41
Location: Fort Pierce, Florida
Climate zone: 2a STATE OF
Project Type: New Construction ,wO*% ' •••�
Vertical Glazing / Wall Area: 10% I�S �•;•0 R: O•••d`�
ONAL -.i •
Construction Site:
4946 S 25th St
Ft Pierce, Florida 34981
Owner/Agent:
Joe Mann, Sr
Verdad Real Estate
1211 South White Chapel Blvd
Suite 100
Southlake, Texas 76092
504-777-3894
Additional Efficiency Package(s)
Reduced interior lighting power. Requirements are implicitly enforced
Building Area
1-Dining: Cafeteria/Fast Food : Nonresidential
Envelope Assemblies
Assembly
Roof: Insulation Entirely Above Deck, 3-Year-Aged Solar Reflectance =
0.55, Thermal Emittance = 0.75 (d), [Bldg. Use 1 - Dining:
Cafeteria/Fast Food]
Floor: Unheated Slab -On -Grade, [Bldg. Use 1 - Dining: Cafeteria/Fast
Food] (c)
NORTH
Ext. Wall: Concrete Block, 8in., Partially Grouted, Cells Empty, Light
Density, Furring: Wood, [Bldg. Use 1 - Dining: Cafeteria/Fast Food]
Door: Insulated Metal, Swinging, [Bldg. Use 1 - Dining: Cafeteria/Fast
Food]
EAST
Ext. Wall: Concrete Block, 8in., Partially Grouted, Cells Empty, Light
Density, Furring: Wood, [Bldg. Use 1 - Dining: Cafeteria/Fast Food]
Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product
ID NA, SHGC 0.40, PF 2.00, [Bldg. Use 1 - Dining: Cafeteria/Fast
Food] (b)
SOUTH
Ext. Wall: Concrete Block, 81n., Partially Grouted, Cells Empty, Light
Density, Furring: Wood, [Bldg. Use 1 - Dining: Cafeteria/Fast Food]
Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product
ID NA, SHGC 0.40, PF 2.00, [Bldg. Use 1 - Dining:
Project Title: Popeyes Ft Pierce, FL
Data filename:
Designer/Contractor:
Clark Stilwell
LIS Engineering
2572 West SR 426,Suite 2064
Suite 2064
Oviedo 32765
321-244-0402
clarks@lis-ae.com
interior lighting allowance calculations.
Floor Area
2265
Gross Area Cavity
Cont.
Proposed
Budget U-
or R-Value
R Value
U-Factor
Factor(.)
Perimeter
2265 --
30.0
0.032
0.039
225 --
--
0.730
0.730
520 8.0
4.4
0.070
0.151
28 --
--
1.250
0.610
1248
8.0 ' 4.4 0.070
0.151
105
-- -- 0.500
0.500
520
8.0 4.4 0.070
0.151
127
— -- 0.500
0.500
FILE
COPY
Report date: 12/05/18
Page 1 of 23
Assembly
Gross Area Cavity Cont. Proposed Budget U-
or R-Value R-Value U-Factor Factor(.)
Perimeter
Cafeteria/Fast Food] (b)
WEST
Ext. Wall: Concrete Block, 8in., Partially Grouted, Cells Empty, Light 1248 8.0 4.4 0.070 0.151
Density, Furring: Wood, [Bldg. Use 1 - Dining: Cafeteria/Fast Food]
Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Produc 115 -- — 0.500 0.500
ID NA, SHGC 0.40, PF 2.00, [Bldg. Use 1 - Dining: Cafeteria/Fast
Food] (b)
(a) Budget U-factors are used for software baseline calculations ON -Y, and are not code requirements.
(b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
(c) Slab -On -Grade proposed and budget U-factors shown in table a le F-factors.
(d) High albedo roof requirement options: 1) 3-year aged solar reflectance — 0.55 thermal emittance — 0.75, 2) 3-year aged solar reflectance
index — 64.0, 3) Initial year aged solar reflectance — 0.70 thermal emittance — 0.75, 4) Initial year aged solar reflectance index — 82.0.
Envelope Compliance Statement
Compliance Statement. The proposed envelope design repres nted in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed envelope systems have been
designed to meet the 2017 Florida Building Code, Energy Cons�rvat(on requirements in COMcheck Version COMcheck-Web and
to comply with any applicable mandatory requirements listed iri the Inspection Checklist.
Clark Stilwell - MEP Director /' /g
Name - Title Signature) Date
Project Title: Popeyes Ft Pierce, FL
Data filename:
Report date: 12/05/18
Page 2 of 23
COMcheck Software Version COMcheck-Web
Interior Lighting ompliance Certificate
Project Information
Energy Code:
Project Title:
Project Type:
Construction Site:
4946 S 25th St
Ft Pierce, Florida 34981
Additional Efficiency Package(s)
2017 Florida Building Code, Energy Conservation
Popeyes Ft Pierce, FL
New Construction
Owner/Agent:
Joe Mann, Sr
Verdad Real Estate
1211 South WhitE Chapel Blvd
Suite 100
Southlake, Texas 76092
504-777-3894
Reduced interior lighting power. Requirements are implicitly enforced
Allowed Interior Lighting Power
A
Area Category
Designer/Contractor:
Clark Stilwell
LIS Engineering
2572 West SR 426,Suite 2064
Suite 2064
Oviedo 32765
321-244-0402
clarks@lis-ae.com
interior lighting allowance calculations.
B C D
Floor Area Allowed Allowed Watts
(ft2) Watts / ft2
1-Dining: Cafeteria/Fast Food
12265
0.81
1835
Total Allowed Watts =
1835
Proposed Interior Lighting Power
A
B
C D
E
Fixture ID : Description / Lamp / Wattage Per Lan
p / Ballast
Lamps/
# of Fixture
(C X D)
Fixture
Fixture Watt.
1-Dining: Cafeteria/Fast Food
LED: A: 2x4 Troffer: LED Linear Lamp 33W:
1
15 32
480
LED: LL3, LL4: Downlight & Pendant: LED PAR 15W:
1
50 15
750
LED: C: Wallwasher: LED A Lamp 25W:
1
8 26
208
Total Proposed Wafts =
1438
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been
designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version COMcheck-Web and
to comply with any applicable mandatory requirements listed in' the Inspection Checklist.
OF
Clark Stilwell - MEP Director
Name - Title Signature l Date
Project Title: Popeyes Ft Pierce, FL
Data filename:
Report date: 12/05/18
Page 3 of 23
�( COMcheck Software Version COMcheck-Web
Exterior Lighting Compliance Certificate
Project Information
Energy Code:
Project Title:
Project Type:
Exterior Lighting Zone
Construction Site:
4946 S 25th St
Ft Pierce, Florida 34981
Allowed Exterior Lighting Power
A
Area/Surface Category
2017 Florida Building
Popeyes Ft Pierce, FI
New Construction
2 (Neighborhood busi
Owner/Agent:
Joe Mann, Sr
Verdad Real Esta
1211 South Whit(
Suite 100
Southlake, Texas
504-777-3894
Energy Conservation
district)
Designer/Contractor:
Clark Stilwell
LIS Engineering
:hapel Blvd 2572 West SR 426,Suite 2064
Suite 2064
6092 Oviedo 32765
321-244-0402
clarks@lis-ae.com
B C D E
Quantity Allowed Tradable Allowed Watts
Watts / Wattage (B X C)
rarKmg Lot trarKing area) 43250 ft2 0.06 Yes 2595
Entry canopy (Entry canopy) 3536 ft2 0.25 Yes 884
Total Tradable Watts (a) = 3479
Total Allowed Watts = 3479
Total Allowed Supplemental Watts (b) = 600
(a) Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b) A supplemental allowance equal to 600 watts may be applied toward compliance of both non -tradable and tradable areas/surfaces.
Proposed Exterior Lighting Power
A B C D E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixture Watt.
Parking Lot (Parking area 43250 ft2): Tradable Wattage
LED: A: Site Light: LED Roadway/Parking Unit 223W: 1 6 280 1680
Entry canopy (Entry canopy, 3536 ft2): Tradable Wattage
LED: D,D1,H: Balcony Soffit: Other: 1 14 100 1400
LED: E: Mansard Wall Mount: LED A Lamp 25W: 1 9 26 234
Total Tradable Proposed Watts = 331 4
Exterior Lighting Compliance Statement
Compliance Statement. The proposed exterior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been
designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version COMcheck-Web and
to comply with any applicable mandatory requirements listed in the Inspection Checklist.
Project Title: Popeyes Ft Pierce, FL Report date: 12/05/18
Data filename: Page 4 of 23
i
Clark Stilwell - MEP Director l
Name - Title Signature; Date
Project Title: Popeyes Ft Pierce, FL Report date: 12/05/18
Data filename: Page 5 of 23
6�(
COMcheck Software Version COMcheck-Web
Mechanical Compliance Certificate
Project Information
Energy Code:
Project Title:
Location:
Climate Zone:
Project Type:
Construction Site:
4946 S 25th St
Ft Pierce, Florida 34981
Additional Efficiency Package(s)
2017 Florida Building
Popeyes Ft Pierce, FL
Fort Pierce, Florida
2a
New Construction
Energy Conservation
Owner/Agent:
Joe Mann, Sr
Verdad Real Esta e
1211 South Whit Chapel Blvd
Suite 100
Southlake, Texas 76092
504-777-3894
Reduced interior lighting power. Requirements are implicitly enforced
Mechanical Systems List
Quantity System Type & Description
3 HVAC System (Single Zone):
Heating: 3 each - Other, Electric, Capacity = 64 kBtu/h
No minimum efficiency requirement applies
Cooling: 3 each - Single Package DX Unit, Capacity = 10:
Humidity Requirements
Proposed Efficiency = 11.20 EER, Required Efficiency:
Fan System: FAN SYSTEM 11 RTU-1,2,3 — Compliance
Fans:
RTU-1,2,3 Supply, Constant Volume, 3400 CFM, 3.0
grade
Water Heater:
Electric Storage Water Heater, Capacity: 85 gallons w/
Proposed Efficiency: 100.00 EF, Required Efficiency:
Mechanical Compliance Statement
Compliance Statement: The proposed mechanical design repre
specifications, and other calculations submitted with this perm!
designed to meet the 2017 Florida Building Code, Energy Cons(
to comply with any applicable mandatory requirements listed it
Project Title: Popeyes Ft Pierce, FL
Data filename:
Designer/Contractor:
Clark Stilwell
LIS Engineering
2572 West SR 426,Suite 2064
Suite 2064
Oviedo 32765
321-244-0402
clarks@lis-ae.com
in interior lighting allowance calculations.
kBtu/h, Air -Cooled Condenser, No Economizer, Economizer exception:
70 EER + 11.2 IEER
�ake HP method) : Passes
nameplate hp, 2.4 design brake hp (2.4 max. BHP), 85.0 fan efficiency
Pump
EF
rented in this document is consistent with the building plans,
application. The proposed mechanical systems have been
rvation requirements in COMcheck Version COMcheck-Web and
the Inspection Checklist.
Report date: 12/05/18
Page 6 of 23
%.uiwcnecK boTrware version LuMcnecK-web
Inspection Checklist
Energy Code: 2017 Florida Building Code, Energy Conservation
Requirements: 100.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provid d by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requiremenll will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a se Tarate table, a reference to that table is provided.
Section
#-
Plan Review
Complies?
Comments/Assumptions
& Req.ID
C103.2
Plans and/or specifications provide all ;❑Complies
:Requirement will be met.
[PR111
! information with which compliance ;❑Does No
can be determined for the building ;
;
(envelope and document where ❑N0t Obs
rvable
exceptions to the standard are ;❑Not Applicable
;
Maimed.
C103.2
Plans, specifications, and/or ;❑Complie
(calculations
:Requirement will be met.
[PR211
provide all information ❑Does No
with which compliance can be ;❑Not Obs
determined for the mechanical
rvable
jsystems and equipment and ;❑Not Applicable
document where exceptions to the
standard are claimed. Load
calculations per acceptable ;
engineering standards and
handbooks.
;
C103.2
[PR3]1
Plans, specifications, and/or ;❑Complie
!Plans I calcu'
(calculations provide all information !❑Does No
:Requirement will be met.
(with which compliance can be
I determined for the service water !❑Not Obs
rvable
1 heating systems and equipment and ❑Not Applicable
;
I document where exceptions to' the
!standard
are claimed. Hot water
'system sized per manufacturer's
;
!sizing guide.
1
C405.6
[PR17j1
Plans, specifications, and/or ;❑Complies
calculations provide all information :❑Does Not
;Requirement will be met.
with which compliance can be
determined for the electrical systems !❑Not Observable
;
!
I
and equipment and document where ;❑Not Applicable
;
rexceptions
are claimed. Provisions are;
made for metering individual tenant
units. Feeder connectors (for feeder
;and
branch circuits) sized in ,
I
accordance with approved plans with
maximum drop of 5% voltage drop !
;
;
total.
C103.2 !Plans, specifications, and/or ;❑Compliesl
;Requirement will be met.
[PR411 !calculations provide all information !❑Does Not
)with which compliance can be
determined for the interior lighting -]Not Observable;
and electrical systems and equipment :❑Not Applicable
!and document where exceptions to !
lthe standard are claimed. Information
,provided should include interior
lighting power calculations, wattage of
!bulbs and ballasts, transformers and
,control devices.
;
1 I High Impact (Tier 1) 2 1 Mediujn Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Popeyes Ft Pierce, FL Report date: 12/05/18
Data filename: Page 7 of 23
Section -
# Plan Review Compliles7 Comments/Assumptions
C103.2 ' Plans, specifications, and/or ;❑Complies !Requirement will be met.
[PR8)1 'calculations provide all information PDoes Not
,with which compliance can be I
determined for the exterior lighting ❑Not Obs rvable ;
and electrical systems and equipment ❑Not Applicable ;
and document where exceptions to
the standard are claimed. Information ;
provided should include exterior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices. i 1
C402.4.1 ;The vertical fenestration area <= 30 ;❑Complies ;Requirement will be met.
[PR10]1 ;percent of the gross above -grade wall �❑Does No
I rea.
I❑Not Observable
❑Not Applicable
C402.4.1 'The skylight area <= 3 percent of the '❑Complies ;Requirement will be met.
[PR1111 gross roof area. ;❑Does Not
IN Observable
i ;❑Not Applicable
C402.4.2 In enclosed spaces > 2,500 ft2 ;❑Complies ;Exception: Requirement does not apply.
[PR1411 directly under a roof with ceiling 1❑Does Not
'heights >15 ft. and used as an office, ❑Not Observable;
lobby, atrium, concourse, corridor, ;❑Not A likI
storage, gymnasium/exercise center, pp i able
convention center, automotive
service, manufacturing, non- ;
refrigerated warehouse, retail store,
;distribution/sorting area,
transportation, or workshop, the ;
ifollowing requirements apply: (a) the
i daylight zone under skylights is >_
half the floor area; (b) the skylight
;area to daylight zone is >= 3 percent
with a skylight VT >= 0.40; or a
minimum skylight effective aperture
>= 1 percent.
C406 !Plans, specifications, and/or ;❑Complies ;Requirement will be met.
[PR911 calculations provide all information ;❑Does Not
with which compliance can be
I determined for the additional energy ;❑Not Observable:
lefficiency package options. ;❑Not Applicable ;
C402.5.9.(,Ceilings with vented dropped ceiling I❑Complies ;Requirement will be met.
1-4) cavities over conditioned spaces have I❑Does Not
[PR16]1 !a continuous air barrier between the
conditioned space and the vented ❑Not observable
unconditioned space and are sealed to :❑Not Applicable ;
the air barrier of the walls. Unvented
dropped ceiling cavities over
!conditioned spaces without air barrier
!between the conditioned and
unconditioned space are sealed from ;
!the exterior environment and adjacent
spaces by a continuous air barrier and
I is sealed to the air barrier of the walls. 1
Unconditioned spaces above separate
'tenancies contain dividing partitions ;
!between the tenancies to form a I
continuous air barrier that is sealed at
;the ceiling and roof. Building cavities
designed to be air distribution system
components are sealed according to ;
I the criteria for air ducts, plenums, etc.
in Section C403.2.7. I 1
1 I High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Popeyes Ft Pierce, FL Report date: 12/05/18
Data filename: Page 8 of 23
Additional Comments/Assumptions:
11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Popeyes Ft Pierce, FL
Data filename:
Report date: 12/05/18
Page 9 of 23
Section
#
Footing / Foundation Inspection
Complies?
Comments/Assumptions
& Req.ID
C303.2
Slab edge insulation installed per
;❑Complie :Requirement will be met.
[FO4]2
manufacturer's instructions.
;❑Does No
❑Not Obs rvable ; Location on plans/spec: NA
❑Not Appl cable
C303.2.1
',Exterior insulation protected against ;❑Complie
;Requirement will be met.
[FO6]1
"damage, sunlight, moisture, wind, :❑Does
No�j�
landscaping and equipment :[-]NotObservablet
maintenance activities.
,
❑Not Appl{cable ;
C402.2.5
[FO3]2
Slab edge insulation R-value. ;❑Complied
;❑Does
;See the Envelope Assemblies table for values.
Not
❑Not Observable
❑Not Applicable
C402.2.6 (
Radiant heating systems panels ;[]Complied
!Exception: Requirement does not apply.
[FO12]3 !
insulated to >=R-3.5 on face opposite !❑Does
1
N I I
!space
being heated.
:See the Envelope Assemblies table for values.
UNot Obs rvable
I
❑Not Applicable
C403.2.4.
Snow/ice melting system sensors for ;❑Complie
; Exception: Requirement does not apply.
5,
future connection to controls. Freeze
❑Does No
C403.2.4.
protection systems have automatic
P Y
❑Not Observable;
6
[FO9]3
controls installed.
;❑Not
Applicable
Section
#
Framing / Rough -In Inspection
Complies?
Comments/Assumptions
& Req.ID
C303.1.3
Fenestration products rated in ;[]Complies
:Requirement will be met.
[FR12]2
accordance with NFRC. ;❑Does Not
❑Not Obse
able ;
❑Not Applicable
C303.1.3
'Fenestration products are certified as ;❑Complies
; Requirement will be met.
[FR13]1
Ito performance labels or certificates ❑Does Not
provided. ;❑Not Obse
able
❑Not Applicable
C402.4.3
lVertical fenestration SHGC value. ;❑Complies
;See the Envelope Assemblies table for values.
[FR10]1
;❑Does Not
I❑Not Observable
I ;❑Not Applicable
C402.4.3,
i Vertical fenestration U-Factor. ;❑Complied
;See the Envelope Assemblies table for values.
C402.4.3.
;❑Does Noi
4
[FR8]1
I :❑Not Observable
❑Not Applicable
;
C402.4.4
U-factor of opaque doors associated ;❑Complied
;See the Envelope Assemblies table for values.
[FR14]2
with the building thermal envelope ;❑Does No�
meets requirements. I❑Not Observable
❑Not Applicable
;
C402.5.1 IThe
building envelope contains a ;❑Complie
:Requirement will be met.
[FR16]1 i
continuous air barrier that is sealed in I❑Does No
an approved manner and either
constructed or tested in an approved ONot Observable
manner. Air barrier penetrations are I❑Not Appl
,
cable ;
,sealed
in an approved manner.
;
C402.5.2,
Factory -built fenestration and doors ;❑Complie
:Requirement will be met.
C402.5.4
are labeled as meeting air leakage ;❑Does Not
[FR18]3
requirements.
❑Not Observable;
❑Not Applicable
#
Plumbing Rough -In Inspection
Complies?
Comments/Assumptions
& Req.ID
;
C404.5,
I Heated water supply piping conforms
;❑Complie
:Exception: Requirement does not apply.
C404.5.1,
Ito pipe length and volume
I❑Does No
C404.5.2
[PL6]3
requirements. Refer to section details.
;❑Not Obs
rvable ;
;❑Not Appl
cable j
C404.5,
Heated water supply piping conforms
j❑Complie
:Requirement will be met.
C404.5.1,
Ito pipe length and volume
I❑Does Noq
C404.5.2
requirements. Refer to section details.
i❑Not Observable
❑Not Applicable
C404.6.1, IAutomatic time switches installed to ;❑Complies ; Requirement will be met.
C404.6.2 automatically switch off the I❑Does Not
[PL3]1 trace.recirculating hot-water system or heat ;❑Not Observable
I ;❑Not Applicable
C404.6.3 Pumps that circulate water between a I❑Complies ;Exception: Requirement does not apply.
[PL7]3 heater and storage tank have controls ;❑Does Note
that limit operation from startup to I
<= 5 minutes after end of heating ❑Not Observable
Icycle. ;❑NotApplcable ;
C40.4.6.3 Pumps that circulate water between a I❑Complies ;Exception: Requirement does not apply.
[PL7]3 heater and storage tank have controls :❑Does Noe
that limit operation from startup to ❑Not Obs
<= 5 minutes after end of heating rvable
cycle. ;❑Not Appl cable ;
C404.7 I Water distribution system that pumps ;❑Complie :Exception: Requirement does not apply.
[PL8]3 water from a heated -water supply ;❑Does Noi
pipe back to the heated -water source 1 1
through a cold -water supply pipe is a ;❑Not Observable ;
i demand recirculation water system. ;❑Not Applicable
Pumps within this system have
controls that start the pump upon
receiving a signal from the action of a
user of a fixture or appliance and ;
limits the temperature of the water
entering the cold -water piping to
104° F.
C404.7 Water distribution system that pumps ;❑Complie ;Requirement will be met.
[PL8]3 water from a heated -water supply I❑Does No I
pipe back to the heated -water source , I I
through a cold -water supply pipe is a ;❑Not Observable
Cdemand recirculation water system. �❑Not Applicable ;
(4 Pumps within this system have
controls that start the pump upon ;
receiving a signal from the action of a
I user of a fixture or appliance and
Climits the temperature of the water 1
entering the cold -water piping to ; I
104°F.
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Popeyes Ft Pierce, FL Report date: 12/05/18
Data filename: Page 12 of 23
Section
I
#
Mechanical Rough -In Inspection
Compll
s2
Comments/Assumptions
& Req.ID
C402.2.6
Thermally ineffective panel surfaces of;❑Complies
; Exception: Requirement does not apply.
[ME41]3
sensible heating panels have ;❑Does Not
insulation >= R-3.5. ;❑Not Obse
able
❑Not Appli
able
C402.5.5,
Stair and elevator shaft vents have ;❑Complies
; Exception: Requirement does not apply.
C403.2.4,
motorized dampers that automatically :,❑Does No
3
[ME3]3
close. :❑Not Observable
;
;❑Not Applicable
C403.2.9.
HVAC ducts and plenums insulated ;❑Complies'
; Requirement will be met.
1.1
and sealed according to Florida ❑Does Not
[ME60]2
Section C403.2.9, Table C403.2.9.1. 1
;❑Not Observable;
❑Not Applicable
C403.2.9.
All ducts, air handlers, filter boxes, ;❑Complies
;Exception: Requirement does not apply.
2
building cavities, mechanical closets ;❑Does No�
[ME79]2
and enclosed support platforms that :
❑Not Obs
I
rvable
form the primary air containment
passageways for air distribution i❑Not Appl
cable
systems are constructed and erected
in accordance with Table C403.2.9.2
;
and with Chapter 6 of the Florida
Building Code, Mechanical. Ducts are
be constructed, braced, reinforced
;
and installed to provide structural
1
strength and durability. All transverse
;
joints, longitudinal seams and fitting
,joints,
are securely fastened in
accordance with the applicable
]standards of this section.
C403:2.9..
Duct insulation is protected from ;❑Complies
; Requirement will be met.
1.2 - .
damage but not limited to the❑Does No
I
[ME80]2
following: 1. Insulation exposed to i❑Not Observable
;
weather is suitable for outdoor
service. Cellular foam insulation is ;❑Not Applicable
protected or painted with a coating
that is water retardant and provides
shielding from solar radiation. 2.
Insulation covering cooling ducts
located outside the conditioned space 1
is vapor retardant located outside the
insulation, all penetrations and joints
of which shall be sealed.
;
C403.2.9. JAdditional
insulation with'vapor ;❑Complies ;Exception: Requirement does not apply.
1.3 1
barrier is provided where the :❑Does Not
[ME81]2 f
minimum duct insulation requirements;
❑No bl t Observae,
of Section C403.2.9.1.1 are ,
determined to be insufficient to :❑Not Applicable
prevent condensation. ; I
C403.2.13
Unenclosed spaces that are heated ;❑Complies :Exception: Requirement does not apply.
[ME71]2
use only radiant heat. ;❑Does Nolt
❑Not Observable
;❑Not Applicable
C403.2.3 ,
HVAC equipment efficiency verified. ;❑Complies ;see the Mechanical systems list for values.
[ME55]2
;❑Does Not
❑Not Observable
❑Not Applicable
h Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 13 I Low Impact (Tier
Project Title: Popeyes Ft Pierce, FL Report date: 12/05/18
Data filename: Page 13 of 23
Section
#
Mechanical Rough -In Inspection
Compliles?
Comments/Assumptions
& Req.ID
I
C403.2.9.
Ducts, air handlers, filter boxes, 1❑Complies
:Requirement will be met.
3
building.cavities, mechanical closets 1❑Does Notl
[ME10]2
and enclosed support platforms that
form the primary air containment j❑Not Observable
Applicable
passageways for air distribution 1❑Not
systems are sealed in accordance with;
the applicable criteria of this section 1
;
and Table C403.2.9.2.
C403.2.9.
4
Cavities in framed spaces are not 1❑Complies
used to deliver air from or return air to ❑Does NoY�
; Exception: Requirement does not apply.
[ME78]2
the conditioning system unless they ❑Not Observable
contain an air duct insert which is
insulated in accordance with Section ❑Not Applicable
C403.2.9.1 and constructed and
sealed in accordance with the
requirements of Section C403.2.9.2 1
appropriate for the duct materials
used.
C403.2.9. JAir
distribution systems are sized and 1❑Complie ;Requirement will be met.
5
designed in accordance with UDoes No
[ME76]z
recognized engineering standards. 1❑Not Observable;
Refer to section details.
,
❑Not Applicable
C403.2.9.
Air -handling units not installed in ;❑Complies ; Requirement will be met.
attics of commercial buildings. ;❑Does Not
2
[ME77]
;❑Not Observable
❑Not Applicable
C408.2.2. lAir
system balancing accomplished in 1❑Complies
:Requirement will be met.
1 ,
a manner to first minimize throttling IF -]Does Noi
[ME53]3
losses, then for fans with fan system ;
Observable
power greater than 1 hp, fan speeds ;❑Not
shall be adjusted to meet design flow 1❑Not Applicable
,
;
!be
conditions. Balancing procedures shall
i
in accordance with NEBB
Procedural Standards, the AABC, 1
;
National Standards, or equivalent
procedures.
C403.2.6. I Demand control ventilation provided ;❑Complie�
:Requirement will be met.
1 Ifor spaces >500 ft2 and >25 1❑Does Not
[ME59]1 I people/1000 ft2 occupant density and ;❑Not Observable
,served by systems with air side
,
(economizer, auto modulating outside 1❑Not Applicable
;
I air damper control, or design airflow
'>3,000 cfm.
C403.2.6. ; Enclosed parking garage ventilation ;❑Complies ;Exception: Requirement does not apply.
2 !has automatic contaminant detection UDoes Not
[ME115]3 land capacity to stage or modulate 1❑Not Observable
)fans to 50% or less of design capacity.
1❑Not Applicable ;
C403.2.7 I Exhaust air energy recovery on 1❑Complies :Exception: Requirement does not apply.
[ME57]1 Isystems meeting Table C403.2.7(1) I❑Does Not
I and C403.2.7(2).
I ❑Not Observable 1
1❑Not Applicable ;
C403.2.8 11 Kitchen exhaust systems comply with 1❑Complies ;Requirement will be met.
[ME116]3 i replacement air and conditioned 1❑Does Not 1
i1supply air limitations, and satisfy hood 1 1
Observable
I rating requirements and maximum ;❑Not
!exhaust rate criteria. 1❑Not Applicable ;
C403.4.4. I Multiple zone VAV systems with DDC '❑Complies Exception: Requirement does not apply.
6 lof individual zone boxes have static 1❑Does Not 1
[ME110]3 l pressure setpoint reset controls. II See the Mechanical Systems list for values.
I I❑Not Observable
{ 1❑Not Applicable 1
1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Popeyes Ft Pierce, FL I Report date: 12/05/18'
Data filename: Page 14 of 23
Section
#
Mechanical Rough -In Inspection
Complil
s?
Comments/Assumptions
& Req.ID
C408.2.2.
Air outlets and zone terminal devices❑Complie
:Requirement will be met.
1
j have means for air balancing. E❑Does
No
[ME53]3
fI
❑Not Obs rvable ;
;❑Not
Applicable
C403.5,
Refrigerated display cases, walk-in ;❑Complies
; Requirement will be met.
C403.5.1,
coolers or walk-in freezers served by
❑Does Not
C403.5.2
[ME123]3
remote compressors and remote I
(condensers not located in a
I
❑Not Observable,
condensing unit, have fan -powered :❑Not
Applicable
condensers that comply with Sections
C403.5.1 and refrigeration compressor;
;
systems that comply with C403.5.2..
I
C403.5.3
Condensing coils installed in cool air ;[]Complies[;
Requirement will be met.
[ME124]3
stream of another air-conditioning I❑Does
No
unit. The condensing coil of one air- 1❑Not
conditioning unit shall not be installed
Obs rvable ;
in the cool air stream of another air- :❑Not
Applicable
conditioning unit. i
Section
#
Rough -In Electrical' Inspection
Complies?
Comments/Assumptions
& Req.ID
C405.2.1
I Lighting controls installed to uniformly
;❑Complies :Requirement will be met.
[EL15]1
reduce the lighting load.by at least
:❑Does Notl
t50%
:❑Not Observable ;
❑Not Applicable
C405.2.1
[EL18]1
;Occupancy sensors installed in ;❑Complied
!required spaces. ;❑Does
;Requirement will be met.
No
f ;❑Not
Obs rvable:
❑Not Applicable
C405.2.1,
Independent lighting controls installed 1❑Complie�
:Requirement will be met.
C405.2.2.
per approved lighting plans and all I❑Does
Not
3
[EL23]z
manual controls readily accessible and;
visible to occupants. :❑Not
Observable
:❑Not
1
Appl cable 1
,
C405.2.2.
Automatic controls to shut off all I❑Complies
I Requirement will be met.
1
building lighting installed in all :❑Does
Noy I
[EL22]2
buildings. 1
E❑Not
I
Observable
:❑Not
Applicable 1
C405.2.3
Daylight zones provided with 1❑Complies
; Exception: Requirement does not apply.
[EL16]2
individual controls that control the ;❑Does
Not
lights independent of general area
lighting. :❑Not
I
Observable
:❑Not
Applicable :
C405.2.3,
C405.2.3.
I Primary sidelighted areas are ;❑Complie' :Exception: Requirement does not apply.
'equipped with required lighting ;❑Does Not
1,
C405.2.3.
2
:controls.
I I❑Not Observable:
:❑Not Applicable
[EL20]1
1
! 1
" I
'
C405.2.3,
Enclosed spaces with daylight area 1❑Complie'Is :Exception: Requirement does not apply.
"under
C405.2.3.
skylights and rooftop monitors
❑Does Not
1,
'controls.
`are equipped with required lighting I❑Not Observable:
C405.2.3.
3
1 iervablel
:❑Not Applicable 1
[EL21]1
'
'
C405.2.4
Separate lighting control devices for :❑Complies
;'Requirement will be met.
[EL4]1 ispecific
uses installed per approved 1❑Does
Not
I
lighting plans. I
:❑Not Observable:
I I
❑Not Applicable
C405.2.4
Additional interior lighting power :❑Complies
:Requirement will be met.
[EL8]1 l
allowed for special functions per the 1❑Does Not
approved lighting plans and is I
:❑Not Observable:
automatically controlled and
separated from general lighting. t]Not Applicable
C405.2.5 ;Automatic
[EL25]nu!l
lighting controls for exterior:❑Complies ;Requirement will be met.
lighting installed. Controls will be 1❑Does Not I
!daylight
controlled, set based on I I I
business operation time -of -day, or UNot Observable
reduce connected lighting > 30%. :❑Not Applicable 1
C405.3
Exit signs do not exceed 5 watts per :❑Complies I Requirement will be met.
[EL6]1 :face.
;❑Does Not
:1-]Not Observable:
I❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 3 1 Low impact (Tier 3)
Project Title: Popeyes Ft Pierce, FL I Report date: 12/05/18
Data filename: Page 16 of 23
#
Insulation Inspection
Complies?
Comments/Assumptions
&'Req.ID
C303.1
!Roof insulation installed per
;❑Complies :Requirement will be met.
[IN3]1
manufacturer's instructions. Blown or
:❑Does No
1poured loose -fill insulation is installed
only where the roof slope is <=3 in
;❑Not Observable ,
12. ;❑Not
Applicable ;
C303.1
Building envelope insulation is labeled ;❑Complies
:Requirement will be met.
[IN10]2
with R-value or insulation certificate j❑Does
Nol
providing R-value and other relevant I
Observable ;
data. :❑Not
i
❑Not Applicable
C303.2
Above -grade wall insulation installed ;❑Complie
:Requirement will be met.
[IN7]1
; per manufacturer's instructions. ;❑Does
Ndt
E
:❑Not
I :Location on plans/spec: NA
Observable
I !❑Not
,
Applicable
C303.2.1
Exterior insulation is protected from
;❑Compli
[IN14]2
damage with a protective material.
:❑Does N
Verification for exposed foundation
❑Not Ob.
insulation may need to occur during
Api
Foundation Inspection.
;❑Not
C402.2.1
Insulation intended to meet the roof
;❑Compli,
[IN17]3
insulation requirements cannot be
E❑Does N
installed on top of a suspended
:❑Not Ob:
ceiling. Mark this requirement
compliant if insulation is installed
I❑Not Apl
accordingly.
C402.2.3
Above -grade wall insulation R-value.
I❑Complii
[IN6]1
I
;❑Does N
I❑Not Ob
❑Not ApJ
C402.2.5
Floor insulation R-value.
;❑Compli1
[IN8]2
;❑Does N
:[:]Not Ob!
C402.2.6
!Radiant panels and associated
{components,
;❑Coml
[IN18]3
designed for heat
:❑Does
transfer from the panel surfaces to the �
occupants or indoor space are
Not C
insulated with a minimum of R-3.5.
I❑Not A
C402.3
High-albedo roofs satisfy one of the
;❑Coml
[IN5]3
following: 3-year-aged solar
;❑Does
reflectance >= 0.55 and thermal
UNot C
emittance >= 0.75 or 3-year-aged
A
solar reflectance index >= 64.0.
;❑Not
C402.2.2
;Roof R-value. For some ceiling
;❑Coml
[IN2]1
(systems, verification may need to
:❑Does
_
Ioccur during Framing Inspection.
I
;-]Not C
❑Not A
C402.5.1.
!All sources of air leakage in the
;❑Comr
1
i building thermal envelope are sealed,
:❑Does
[I111]1
caulked, gasketed, weather stripped
;❑Not C
or wrapped with moisture vapor -
permeable wrapping material to
;❑Not A
minimize air leakage.
,
Additional Comments/Assumptions:
h Impact (Tier 1)
:Exception: Requirement does not apply.
I
able
ble
ervable
licable
ble
;Requirement will be met.
See the Envelope Assemblies table for values.
See the Envelope Assemblies table for values.
,
ervable
licable ;
s ;Exception: Requirement does not apply.
of
servable;
Acable
as ;Requirement will be met.
hservable
;plicable
ies ;See the Envelope Assemblies table for values
Jot
)servable I
iplicable
ies :Requirement will be met.
lot
;servable
plicable
um Impact (Tier 2) 13 1Low Impact (Tier
Project Title: Popeyes Ft Pierce, FL I Report date: 12/05/18
Data filename: Page 18 of 23
Section
#
Final Inspection
Compli gI s7'
Comments/Assumptions
& Req,ID
C303.3,
Furnished O&M instructions for
;❑Complies :Requirement will be met.
C408.2.5.
systems and equipment to the
❑Does No
2
[FI17]3
building owner or designated
representative.
:[--]Not Observable
❑Not Appl cable
C303.3,
!Furnished O&M manuals for HVAC ;❑Complies
:Requirement will be met.
C408.2.5.
Isystems within 90 days of system :❑Does
Not
[FI8]3
!acceptance. :❑Not
Observable
f ;❑Not
Applicable ;
C403.2.4.
Minimum one humidity control device ,[]Complies
:Requirement will be met.
2.4
per installed I❑Does
Not
[FI5613
humidification/dehumidification
I❑Not
I
Observable
system. Controls prevent
;❑Not
simultaneous operation of
Applicable
humidification and dehumidification I
I
equipment.
'
C402.5.3
I Where open combustion air ducts ;❑Complies
!Exception: Requirement is not applicable.
[F[51]3
! provide combustion air to open I❑Does
lyot
{combustion fuel burning appliances,
Ithe appliances and combustion air ;❑Not
'
Observable
opening are located outside the ;❑Not
Applicable
building thermal envelope or enclosed
in a room, isolated from inside the
;
thermal envelope. Such rooms are
sealed and insulated.
;
C402.5.6
I Weatherseals installed on all loading 10Comp ies :Exception: Requirement does not apply.
[FI37]1
(dock cargo doors. ;❑Does of
❑Not O servable
❑Not Applicable
C402.5.8
Recessed luminaires in thermal I❑Complies :Exception: Requirement does not apply.
[FI26]3
envelope to limit infiltration and be IC I❑Does iI
rated and labeled. Seal between
interior finish and luminaire housing. ;❑Not Observable
I❑Not Applicable 1
C403.2.1 {
HVAC systems and equipment design I❑Complies :Requirement will be met.
[FI50]3 I
loads calculated in accordance with !❑DoeslNot
ANSI/ASHRAE/ACCA Standard 183 or
ACCA Manual N or by an approved UNot Observable
equivalent computational procedure. ❑Not Applicable
Design loads shall be attached to the
;
code compliance form submitted to
;
the building department when the
building is permitted or, in the event
the mechanical permit is obtained at a
later time, the sizing calculation shall I
be submitted with the application for
the mechanical permit.
;
C403.2.2
HVAC systems and equipment ;❑Complies ; Requirement will be met.
[FI27]3
capacity does not exceed calculated :[--]Does Not
loads.
I❑Not Observable
❑Not Applicable
C403.2.4.
Heating and cooling to each zone is :❑Complies :Requirement will be met.
1
controlled by a thermostat control. ❑Does Not
[FI47]3
Minimum one humidity control device ;❑Not
Observable
per installed
humidification/dehumidification I❑Not Applicable
j system.
1 1 1 High Impact (Tier 1)1 High Impact (Tier 1) 2�Medium Impact (Tier 2) 3 Low Impact (Tier 3)impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Popeyes Ft Pierce, FL I Report date: 12/05/18
Data filename: Page 19 of 23
Section
#,
Final Inspection
Compli s?
Comments/Assumptions
& Req.ID
C403.2.4.
,Thermostatic controls have a 5 °F :❑Complie :Requirement will be met.
1.2
1deadband. ;❑Does No
[FI38] 3
;❑Not Observable 1
❑Not Applicable ;
C403.2.4.
JTemperature controls have setpoint ;❑Complie :Requirement will be met.
1.3
overlap restrictions. ❑Does No
[FI20]3
❑Not Observable:
❑Not Applicable
C403.2.4.
Each zone equipped with setback ;❑Compliers :Requirement will be met.
2
controls using automatic time clock or ;❑Does Not
[FI39]3
programmable control system.
❑Not Observable :
❑Not Applicable
C404.12.2
Public lavatory facilities equipped with ;❑Compliel's :Requirement will be met.
[FI53]3
outlet devices which limit the flow of ❑Does Not
f hot water to a maximum of 0.5 gpm or;❑Not Observable
are equipped with self -closing valves ; ,
that limit delivery to a per cycle �❑Not Applicable
maximum of 0.25 gallons of hot water
!for
recirculating systems and to a ;
!maximum of 0.50 gallons for non-
i recirculating systems.
C404.12.2
Public lavatory water temperature ;❑Compli✓s ;Requirement will be met.
[FI57]3
<=110°F. ;❑Does Not
❑Not Obl ervable ;
❑Not Applicable
C404.12.1
[FI52]3
Showers used for non -safety reasons ;❑Compliees : Exception: Requirement does not apply,
equipped with flow control devices to :❑Does Not
limit the water discharge to a ;❑Not Observable
maximum of 2.5 gpm per shower
head. Flow restricting inserts used as ;❑Not Applicable
i
a component part of a showerhead
;are mechanically retained at the point ; ;
of manufacture :
C408.2.2
Construction documents require that a:❑Complies :Requirement will be met.
[FI54]3
written balance report be provided to ;❑Does Not
the building owner or rep for HVAC
❑Not Observable
systems serving zones with total I ,
condition area > 5,000 sgft. Air :❑Not Applicable
distribution systems shall be tested,
adjusted, and balanced by a licensed :
engineer or certified company.
C403.2.4.
Automatic Controls: Setback to 55°F :❑Comp ies :Requirement will be met.
2.1, i
(heat) and 85°F (cool); 7-day clock, 2- :❑Does Not
C403.2.4. !hour
occupant override, 10-hour
�❑Not 0 servable
2.2 !1
[F[40]3 E
backup
;❑Not Applicable ;
If ;
C403.2.4. `Systems
include optimum start ;❑Complies ;Exception: Requirement does not apply.
2.3 Econtrols.
;❑DoeslNot
[F141]3
I
;❑Not Observable ;
E
;❑Not applicable
C404.3 ;
[FI11]3 ;discharge
Heat traps installed on supply and ;❑Complies ;Exception: Requirement does not apply.
piping of non -circulating ❑DoeslNot
systems. ;ONot Observable ;
❑Not Applicable
11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Popeyes Ft Pierce, FL I Report date: 12/05/18
Data filename: Page 20 of 23
Section
#
IFinal Inspection
Compli's?
Comments/Assumptions
& Req.ID
. I
C404.4
piping insulated in accordance with
;❑Complies !Requirement will be met.
[FI25]2
section details and Table C403.2.10. 1❑Does
Not
JAll
❑Not Observable
❑Not Applicable
C404.6.1
Controls are installed that limit the ;❑Complies
;Requirement will be met.
[FI12]3
operation of a recirculation pump 1ODoes
Not
installed to maintain temperature of a :❑Not
storage tank. System return pipe is a
Observable
dedicated return pipe or a cold water ;❑Not
Applicable ;
supply pipe.
C405.4.1
[FI18]1
; Interior installed lamp and fixture ;❑Complies
(lighting power is consistent with what ;❑Does
;See the Interior Lighting fixture schedule for values.
Not
is shown on the approved lighting
(plans, demonstrating proposed watts ;❑Not
I
Observable;
Applicable
are less than or equal to allowed ;❑Not
watts.
I
C405.5.1
!Exterior lighting power is consistent ;❑Complies
;See the Exterior Lighting fixture schedule for values.
[FI19]1
with what is shown on the approved :❑Does
Iyof
i lighting plans, demonstrating
I
proposed watts are less than or equal :[:]Not Observable
Ito allowed watts. ;❑Not
Applicable ;
C408.2.1
lCommissioning plan developed by ;❑Comp ies :Requirement will be met.
[F128]1
I registered design professional or
❑Does �ot
{ approved agency.
❑Not 0 servable ;
;❑Not Applicable ;
C408.2.3. ;
1 ,ensure
HVAC equipment has been tested to ;❑Complies ; Exception: Unitary or packaged HVAC eqiupment without
proper operation. ;❑DoeslNot :supply air
[FI31]1
economizers.
;❑Not Observable
❑Not Applicable
C408.2.3.
HVAC control systems have been ;❑Complies :Requirement will be met.
2
nested to ensure proper operation, ❑Does Not
[FI10]1 (calibration
and adjustment of controls. ❑Not Observable ;
❑Not Applicable
C408.2.4 !Preliminary
commissioning report ;❑Complies ; Requirement will be met.
[F129]1 !completed
and certified by registered ❑Does Not
;design
professional or approved I
:❑Not Observable
!agency.
;❑NotlApplicable ;
C408.2.5.
Furnished HVAC as -built drawings ;❑Complies :Requirement will be met.
1 (submitted
within 90 days of system ;❑Does Not
[FI7]3 ,acceptance.
i I
:❑Not' Observable
Ii
f
;❑Not Applicable ;
C408.2.5.
Furnished as -built drawings for ;❑Co plies ;Requirement will be met.
1
electric power systems within 90 days ;❑Does Not
[FI16]3
of system acceptance. I
;❑Not Observable;
❑Noi Applicable
C408.2.5. I An air and/or hydronic system ;❑Complies :Requirement will be met.
ba
3 lancing report is provided for HVAC Does Not i
;❑
[FI43]1 j, systems. ;❑Not Observable:
I
;❑Ndt Applicable
C408.2.5. :Final commissioning report due to ;❑Complies ; Requirement will be met.
4 building owner within 90 days of ;❑Does Not
[F130]1 I receipt of certificate of occupancy. ❑Not Observable
I
;❑Not Applicable
Project Title: Popeyes Ft Pierce, FL
Data filename:
(Tier 1) 2 Medium Impact (Tier 2) 3 I Low Impact (Tier 3)
Report date: 12/05/18
Page 21 of 23
ft
# Final Inspection
& Req.ID
C408.3 Lighting systems have been tested to
[FI3311 ensure proper calibration, adjustment,
programming, and operation.
Additional Comments/Assumptions:
1 I High Impact (Tier 1)
Project Title: Popeyes Ft Pierce, FL
Data filename:
Comments/Assumptions
iplies :Requirement will be met.
s Not
Observable: .
Applicable ;
Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) J
Report date: 12/05/18
Page 22 of 23