HomeMy WebLinkAboutENVELOPE COMPLIANCE CERTIFICATEI COMcheck SoftwaftVaIMOR COMcheck-Web Envelope Compliance Certificate Project Information :��, Q.• •�� SF• •.;� No 446 Energy Code: 2017 Florida Building Code, Energy Conservation f ; Project Title: Popeyes Ft Pierce, F 41 Location: Fort Pierce, Florida Climate zone: 2a STATE OF Project Type: New Construction ,wO*% ' •••� Vertical Glazing / Wall Area: 10% I�S �•;•0 R: O•••d`� ONAL -.i • Construction Site: 4946 S 25th St Ft Pierce, Florida 34981 Owner/Agent: Joe Mann, Sr Verdad Real Estate 1211 South White Chapel Blvd Suite 100 Southlake, Texas 76092 504-777-3894 Additional Efficiency Package(s) Reduced interior lighting power. Requirements are implicitly enforced Building Area 1-Dining: Cafeteria/Fast Food : Nonresidential Envelope Assemblies Assembly Roof: Insulation Entirely Above Deck, 3-Year-Aged Solar Reflectance = 0.55, Thermal Emittance = 0.75 (d), [Bldg. Use 1 - Dining: Cafeteria/Fast Food] Floor: Unheated Slab -On -Grade, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] (c) NORTH Ext. Wall: Concrete Block, 8in., Partially Grouted, Cells Empty, Light Density, Furring: Wood, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] Door: Insulated Metal, Swinging, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] EAST Ext. Wall: Concrete Block, 8in., Partially Grouted, Cells Empty, Light Density, Furring: Wood, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product ID NA, SHGC 0.40, PF 2.00, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] (b) SOUTH Ext. Wall: Concrete Block, 81n., Partially Grouted, Cells Empty, Light Density, Furring: Wood, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product ID NA, SHGC 0.40, PF 2.00, [Bldg. Use 1 - Dining: Project Title: Popeyes Ft Pierce, FL Data filename: Designer/Contractor: Clark Stilwell LIS Engineering 2572 West SR 426,Suite 2064 Suite 2064 Oviedo 32765 321-244-0402 clarks@lis-ae.com interior lighting allowance calculations. Floor Area 2265 Gross Area Cavity Cont. Proposed Budget U- or R-Value R Value U-Factor Factor(.) Perimeter 2265 -- 30.0 0.032 0.039 225 -- -- 0.730 0.730 520 8.0 4.4 0.070 0.151 28 -- -- 1.250 0.610 1248 8.0 ' 4.4 0.070 0.151 105 -- -- 0.500 0.500 520 8.0 4.4 0.070 0.151 127 — -- 0.500 0.500 FILE COPY Report date: 12/05/18 Page 1 of 23 Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor(.) Perimeter Cafeteria/Fast Food] (b) WEST Ext. Wall: Concrete Block, 8in., Partially Grouted, Cells Empty, Light 1248 8.0 4.4 0.070 0.151 Density, Furring: Wood, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Produc 115 -- — 0.500 0.500 ID NA, SHGC 0.40, PF 2.00, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] (b) (a) Budget U-factors are used for software baseline calculations ON -Y, and are not code requirements. (b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c) Slab -On -Grade proposed and budget U-factors shown in table a le F-factors. (d) High albedo roof requirement options: 1) 3-year aged solar reflectance — 0.55 thermal emittance — 0.75, 2) 3-year aged solar reflectance index — 64.0, 3) Initial year aged solar reflectance — 0.70 thermal emittance — 0.75, 4) Initial year aged solar reflectance index — 82.0. Envelope Compliance Statement Compliance Statement. The proposed envelope design repres nted in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2017 Florida Building Code, Energy Cons�rvat(on requirements in COMcheck Version COMcheck-Web and to comply with any applicable mandatory requirements listed iri the Inspection Checklist. Clark Stilwell - MEP Director /' /g Name - Title Signature) Date Project Title: Popeyes Ft Pierce, FL Data filename: Report date: 12/05/18 Page 2 of 23 COMcheck Software Version COMcheck-Web Interior Lighting ompliance Certificate Project Information Energy Code: Project Title: Project Type: Construction Site: 4946 S 25th St Ft Pierce, Florida 34981 Additional Efficiency Package(s) 2017 Florida Building Code, Energy Conservation Popeyes Ft Pierce, FL New Construction Owner/Agent: Joe Mann, Sr Verdad Real Estate 1211 South WhitE Chapel Blvd Suite 100 Southlake, Texas 76092 504-777-3894 Reduced interior lighting power. Requirements are implicitly enforced Allowed Interior Lighting Power A Area Category Designer/Contractor: Clark Stilwell LIS Engineering 2572 West SR 426,Suite 2064 Suite 2064 Oviedo 32765 321-244-0402 clarks@lis-ae.com interior lighting allowance calculations. B C D Floor Area Allowed Allowed Watts (ft2) Watts / ft2 1-Dining: Cafeteria/Fast Food 12265 0.81 1835 Total Allowed Watts = 1835 Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lan p / Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. 1-Dining: Cafeteria/Fast Food LED: A: 2x4 Troffer: LED Linear Lamp 33W: 1 15 32 480 LED: LL3, LL4: Downlight & Pendant: LED PAR 15W: 1 50 15 750 LED: C: Wallwasher: LED A Lamp 25W: 1 8 26 208 Total Proposed Wafts = 1438 Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version COMcheck-Web and to comply with any applicable mandatory requirements listed in' the Inspection Checklist. OF Clark Stilwell - MEP Director Name - Title Signature l Date Project Title: Popeyes Ft Pierce, FL Data filename: Report date: 12/05/18 Page 3 of 23 �( COMcheck Software Version COMcheck-Web Exterior Lighting Compliance Certificate Project Information Energy Code: Project Title: Project Type: Exterior Lighting Zone Construction Site: 4946 S 25th St Ft Pierce, Florida 34981 Allowed Exterior Lighting Power A Area/Surface Category 2017 Florida Building Popeyes Ft Pierce, FI New Construction 2 (Neighborhood busi Owner/Agent: Joe Mann, Sr Verdad Real Esta 1211 South Whit( Suite 100 Southlake, Texas 504-777-3894 Energy Conservation district) Designer/Contractor: Clark Stilwell LIS Engineering :hapel Blvd 2572 West SR 426,Suite 2064 Suite 2064 6092 Oviedo 32765 321-244-0402 clarks@lis-ae.com B C D E Quantity Allowed Tradable Allowed Watts Watts / Wattage (B X C) rarKmg Lot trarKing area) 43250 ft2 0.06 Yes 2595 Entry canopy (Entry canopy) 3536 ft2 0.25 Yes 884 Total Tradable Watts (a) = 3479 Total Allowed Watts = 3479 Total Allowed Supplemental Watts (b) = 600 (a) Wattage tradeoffs are only allowed between tradable areas/surfaces. (b) A supplemental allowance equal to 600 watts may be applied toward compliance of both non -tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. Parking Lot (Parking area 43250 ft2): Tradable Wattage LED: A: Site Light: LED Roadway/Parking Unit 223W: 1 6 280 1680 Entry canopy (Entry canopy, 3536 ft2): Tradable Wattage LED: D,D1,H: Balcony Soffit: Other: 1 14 100 1400 LED: E: Mansard Wall Mount: LED A Lamp 25W: 1 9 26 234 Total Tradable Proposed Watts = 331 4 Exterior Lighting Compliance Statement Compliance Statement. The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version COMcheck-Web and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Project Title: Popeyes Ft Pierce, FL Report date: 12/05/18 Data filename: Page 4 of 23 i Clark Stilwell - MEP Director l Name - Title Signature; Date Project Title: Popeyes Ft Pierce, FL Report date: 12/05/18 Data filename: Page 5 of 23 6�( COMcheck Software Version COMcheck-Web Mechanical Compliance Certificate Project Information Energy Code: Project Title: Location: Climate Zone: Project Type: Construction Site: 4946 S 25th St Ft Pierce, Florida 34981 Additional Efficiency Package(s) 2017 Florida Building Popeyes Ft Pierce, FL Fort Pierce, Florida 2a New Construction Energy Conservation Owner/Agent: Joe Mann, Sr Verdad Real Esta e 1211 South Whit Chapel Blvd Suite 100 Southlake, Texas 76092 504-777-3894 Reduced interior lighting power. Requirements are implicitly enforced Mechanical Systems List Quantity System Type & Description 3 HVAC System (Single Zone): Heating: 3 each - Other, Electric, Capacity = 64 kBtu/h No minimum efficiency requirement applies Cooling: 3 each - Single Package DX Unit, Capacity = 10: Humidity Requirements Proposed Efficiency = 11.20 EER, Required Efficiency: Fan System: FAN SYSTEM 11 RTU-1,2,3 — Compliance Fans: RTU-1,2,3 Supply, Constant Volume, 3400 CFM, 3.0 grade Water Heater: Electric Storage Water Heater, Capacity: 85 gallons w/ Proposed Efficiency: 100.00 EF, Required Efficiency: Mechanical Compliance Statement Compliance Statement: The proposed mechanical design repre specifications, and other calculations submitted with this perm! designed to meet the 2017 Florida Building Code, Energy Cons( to comply with any applicable mandatory requirements listed it Project Title: Popeyes Ft Pierce, FL Data filename: Designer/Contractor: Clark Stilwell LIS Engineering 2572 West SR 426,Suite 2064 Suite 2064 Oviedo 32765 321-244-0402 clarks@lis-ae.com in interior lighting allowance calculations. kBtu/h, Air -Cooled Condenser, No Economizer, Economizer exception: 70 EER + 11.2 IEER �ake HP method) : Passes nameplate hp, 2.4 design brake hp (2.4 max. BHP), 85.0 fan efficiency Pump EF rented in this document is consistent with the building plans, application. The proposed mechanical systems have been rvation requirements in COMcheck Version COMcheck-Web and the Inspection Checklist. Report date: 12/05/18 Page 6 of 23 %.uiwcnecK boTrware version LuMcnecK-web Inspection Checklist Energy Code: 2017 Florida Building Code, Energy Conservation Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provid d by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requiremenll will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a se Tarate table, a reference to that table is provided. Section #- Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans and/or specifications provide all ;❑Complies :Requirement will be met. [PR111 ! information with which compliance ;❑Does No can be determined for the building ; ; (envelope and document where ❑N0t Obs rvable exceptions to the standard are ;❑Not Applicable ; Maimed. C103.2 Plans, specifications, and/or ;❑Complie (calculations :Requirement will be met. [PR211 provide all information ❑Does No with which compliance can be ;❑Not Obs determined for the mechanical rvable jsystems and equipment and ;❑Not Applicable document where exceptions to the standard are claimed. Load calculations per acceptable ; engineering standards and handbooks. ; C103.2 [PR3]1 Plans, specifications, and/or ;❑Complie !Plans I calcu' (calculations provide all information !❑Does No :Requirement will be met. (with which compliance can be I determined for the service water !❑Not Obs rvable 1 heating systems and equipment and ❑Not Applicable ; I document where exceptions to' the !standard are claimed. Hot water 'system sized per manufacturer's ; !sizing guide. 1 C405.6 [PR17j1 Plans, specifications, and/or ;❑Complies calculations provide all information :❑Does Not ;Requirement will be met. with which compliance can be determined for the electrical systems !❑Not Observable ; ! I and equipment and document where ;❑Not Applicable ; rexceptions are claimed. Provisions are; made for metering individual tenant units. Feeder connectors (for feeder ;and branch circuits) sized in , I accordance with approved plans with maximum drop of 5% voltage drop ! ; ; total. C103.2 !Plans, specifications, and/or ;❑Compliesl ;Requirement will be met. [PR411 !calculations provide all information !❑Does Not )with which compliance can be determined for the interior lighting -]Not Observable; and electrical systems and equipment :❑Not Applicable !and document where exceptions to ! lthe standard are claimed. Information ,provided should include interior lighting power calculations, wattage of !bulbs and ballasts, transformers and ,control devices. ; 1 I High Impact (Tier 1) 2 1 Mediujn Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Popeyes Ft Pierce, FL Report date: 12/05/18 Data filename: Page 7 of 23 Section - # Plan Review Compliles7 Comments/Assumptions C103.2 ' Plans, specifications, and/or ;❑Complies !Requirement will be met. [PR8)1 'calculations provide all information PDoes Not ,with which compliance can be I determined for the exterior lighting ❑Not Obs rvable ; and electrical systems and equipment ❑Not Applicable ; and document where exceptions to the standard are claimed. Information ; provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. i 1 C402.4.1 ;The vertical fenestration area <= 30 ;❑Complies ;Requirement will be met. [PR10]1 ;percent of the gross above -grade wall �❑Does No I rea. I❑Not Observable ❑Not Applicable C402.4.1 'The skylight area <= 3 percent of the '❑Complies ;Requirement will be met. [PR1111 gross roof area. ;❑Does Not IN Observable i ;❑Not Applicable C402.4.2 In enclosed spaces > 2,500 ft2 ;❑Complies ;Exception: Requirement does not apply. [PR1411 directly under a roof with ceiling 1❑Does Not 'heights >15 ft. and used as an office, ❑Not Observable; lobby, atrium, concourse, corridor, ;❑Not A likI storage, gymnasium/exercise center, pp i able convention center, automotive service, manufacturing, non- ; refrigerated warehouse, retail store, ;distribution/sorting area, transportation, or workshop, the ; ifollowing requirements apply: (a) the i daylight zone under skylights is >_ half the floor area; (b) the skylight ;area to daylight zone is >= 3 percent with a skylight VT >= 0.40; or a minimum skylight effective aperture >= 1 percent. C406 !Plans, specifications, and/or ;❑Complies ;Requirement will be met. [PR911 calculations provide all information ;❑Does Not with which compliance can be I determined for the additional energy ;❑Not Observable: lefficiency package options. ;❑Not Applicable ; C402.5.9.(,Ceilings with vented dropped ceiling I❑Complies ;Requirement will be met. 1-4) cavities over conditioned spaces have I❑Does Not [PR16]1 !a continuous air barrier between the conditioned space and the vented ❑Not observable unconditioned space and are sealed to :❑Not Applicable ; the air barrier of the walls. Unvented dropped ceiling cavities over !conditioned spaces without air barrier !between the conditioned and unconditioned space are sealed from ; !the exterior environment and adjacent spaces by a continuous air barrier and I is sealed to the air barrier of the walls. 1 Unconditioned spaces above separate 'tenancies contain dividing partitions ; !between the tenancies to form a I continuous air barrier that is sealed at ;the ceiling and roof. Building cavities designed to be air distribution system components are sealed according to ; I the criteria for air ducts, plenums, etc. in Section C403.2.7. I 1 1 I High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Popeyes Ft Pierce, FL Report date: 12/05/18 Data filename: Page 8 of 23 Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Popeyes Ft Pierce, FL Data filename: Report date: 12/05/18 Page 9 of 23 Section # Footing / Foundation Inspection Complies? Comments/Assumptions & Req.ID C303.2 Slab edge insulation installed per ;❑Complie :Requirement will be met. [FO4]2 manufacturer's instructions. ;❑Does No ❑Not Obs rvable ; Location on plans/spec: NA ❑Not Appl cable C303.2.1 ',Exterior insulation protected against ;❑Complie ;Requirement will be met. [FO6]1 "damage, sunlight, moisture, wind, :❑Does No�j� landscaping and equipment :[-]NotObservablet maintenance activities. , ❑Not Appl{cable ; C402.2.5 [FO3]2 Slab edge insulation R-value. ;❑Complied ;❑Does ;See the Envelope Assemblies table for values. Not ❑Not Observable ❑Not Applicable C402.2.6 ( Radiant heating systems panels ;[]Complied !Exception: Requirement does not apply. [FO12]3 ! insulated to >=R-3.5 on face opposite !❑Does 1 N I I !space being heated. :See the Envelope Assemblies table for values. UNot Obs rvable I ❑Not Applicable C403.2.4. Snow/ice melting system sensors for ;❑Complie ; Exception: Requirement does not apply. 5, future connection to controls. Freeze ❑Does No C403.2.4. protection systems have automatic P Y ❑Not Observable; 6 [FO9]3 controls installed. ;❑Not Applicable Section # Framing / Rough -In Inspection Complies? Comments/Assumptions & Req.ID C303.1.3 Fenestration products rated in ;[]Complies :Requirement will be met. [FR12]2 accordance with NFRC. ;❑Does Not ❑Not Obse able ; ❑Not Applicable C303.1.3 'Fenestration products are certified as ;❑Complies ; Requirement will be met. [FR13]1 Ito performance labels or certificates ❑Does Not provided. ;❑Not Obse able ❑Not Applicable C402.4.3 lVertical fenestration SHGC value. ;❑Complies ;See the Envelope Assemblies table for values. [FR10]1 ;❑Does Not I❑Not Observable I ;❑Not Applicable C402.4.3, i Vertical fenestration U-Factor. ;❑Complied ;See the Envelope Assemblies table for values. C402.4.3. ;❑Does Noi 4 [FR8]1 I :❑Not Observable ❑Not Applicable ; C402.4.4 U-factor of opaque doors associated ;❑Complied ;See the Envelope Assemblies table for values. [FR14]2 with the building thermal envelope ;❑Does No� meets requirements. I❑Not Observable ❑Not Applicable ; C402.5.1 IThe building envelope contains a ;❑Complie :Requirement will be met. [FR16]1 i continuous air barrier that is sealed in I❑Does No an approved manner and either constructed or tested in an approved ONot Observable manner. Air barrier penetrations are I❑Not Appl , cable ; ,sealed in an approved manner. ; C402.5.2, Factory -built fenestration and doors ;❑Complie :Requirement will be met. C402.5.4 are labeled as meeting air leakage ;❑Does Not [FR18]3 requirements. ❑Not Observable; ❑Not Applicable # Plumbing Rough -In Inspection Complies? Comments/Assumptions & Req.ID ; C404.5, I Heated water supply piping conforms ;❑Complie :Exception: Requirement does not apply. C404.5.1, Ito pipe length and volume I❑Does No C404.5.2 [PL6]3 requirements. Refer to section details. ;❑Not Obs rvable ; ;❑Not Appl cable j C404.5, Heated water supply piping conforms j❑Complie :Requirement will be met. C404.5.1, Ito pipe length and volume I❑Does Noq C404.5.2 requirements. Refer to section details. i❑Not Observable ❑Not Applicable C404.6.1, IAutomatic time switches installed to ;❑Complies ; Requirement will be met. C404.6.2 automatically switch off the I❑Does Not [PL3]1 trace.recirculating hot-water system or heat ;❑Not Observable I ;❑Not Applicable C404.6.3 Pumps that circulate water between a I❑Complies ;Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls ;❑Does Note that limit operation from startup to I <= 5 minutes after end of heating ❑Not Observable Icycle. ;❑NotApplcable ; C40.4.6.3 Pumps that circulate water between a I❑Complies ;Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls :❑Does Noe that limit operation from startup to ❑Not Obs <= 5 minutes after end of heating rvable cycle. ;❑Not Appl cable ; C404.7 I Water distribution system that pumps ;❑Complie :Exception: Requirement does not apply. [PL8]3 water from a heated -water supply ;❑Does Noi pipe back to the heated -water source 1 1 through a cold -water supply pipe is a ;❑Not Observable ; i demand recirculation water system. ;❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and ; limits the temperature of the water entering the cold -water piping to 104° F. C404.7 Water distribution system that pumps ;❑Complie ;Requirement will be met. [PL8]3 water from a heated -water supply I❑Does No I pipe back to the heated -water source , I I through a cold -water supply pipe is a ;❑Not Observable Cdemand recirculation water system. �❑Not Applicable ; (4 Pumps within this system have controls that start the pump upon ; receiving a signal from the action of a I user of a fixture or appliance and Climits the temperature of the water 1 entering the cold -water piping to ; I 104°F. Additional Comments/Assumptions: 1 I High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Popeyes Ft Pierce, FL Report date: 12/05/18 Data filename: Page 12 of 23 Section I # Mechanical Rough -In Inspection Compll s2 Comments/Assumptions & Req.ID C402.2.6 Thermally ineffective panel surfaces of;❑Complies ; Exception: Requirement does not apply. [ME41]3 sensible heating panels have ;❑Does Not insulation >= R-3.5. ;❑Not Obse able ❑Not Appli able C402.5.5, Stair and elevator shaft vents have ;❑Complies ; Exception: Requirement does not apply. C403.2.4, motorized dampers that automatically :,❑Does No 3 [ME3]3 close. :❑Not Observable ; ;❑Not Applicable C403.2.9. HVAC ducts and plenums insulated ;❑Complies' ; Requirement will be met. 1.1 and sealed according to Florida ❑Does Not [ME60]2 Section C403.2.9, Table C403.2.9.1. 1 ;❑Not Observable; ❑Not Applicable C403.2.9. All ducts, air handlers, filter boxes, ;❑Complies ;Exception: Requirement does not apply. 2 building cavities, mechanical closets ;❑Does No� [ME79]2 and enclosed support platforms that : ❑Not Obs I rvable form the primary air containment passageways for air distribution i❑Not Appl cable systems are constructed and erected in accordance with Table C403.2.9.2 ; and with Chapter 6 of the Florida Building Code, Mechanical. Ducts are be constructed, braced, reinforced ; and installed to provide structural 1 strength and durability. All transverse ; joints, longitudinal seams and fitting ,joints, are securely fastened in accordance with the applicable ]standards of this section. C403:2.9.. Duct insulation is protected from ;❑Complies ; Requirement will be met. 1.2 - . damage but not limited to the❑Does No I [ME80]2 following: 1. Insulation exposed to i❑Not Observable ; weather is suitable for outdoor service. Cellular foam insulation is ;❑Not Applicable protected or painted with a coating that is water retardant and provides shielding from solar radiation. 2. Insulation covering cooling ducts located outside the conditioned space 1 is vapor retardant located outside the insulation, all penetrations and joints of which shall be sealed. ; C403.2.9. JAdditional insulation with'vapor ;❑Complies ;Exception: Requirement does not apply. 1.3 1 barrier is provided where the :❑Does Not [ME81]2 f minimum duct insulation requirements; ❑No bl t Observae, of Section C403.2.9.1.1 are , determined to be insufficient to :❑Not Applicable prevent condensation. ; I C403.2.13 Unenclosed spaces that are heated ;❑Complies :Exception: Requirement does not apply. [ME71]2 use only radiant heat. ;❑Does Nolt ❑Not Observable ;❑Not Applicable C403.2.3 , HVAC equipment efficiency verified. ;❑Complies ;see the Mechanical systems list for values. [ME55]2 ;❑Does Not ❑Not Observable ❑Not Applicable h Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 13 I Low Impact (Tier Project Title: Popeyes Ft Pierce, FL Report date: 12/05/18 Data filename: Page 13 of 23 Section # Mechanical Rough -In Inspection Compliles? Comments/Assumptions & Req.ID I C403.2.9. Ducts, air handlers, filter boxes, 1❑Complies :Requirement will be met. 3 building.cavities, mechanical closets 1❑Does Notl [ME10]2 and enclosed support platforms that form the primary air containment j❑Not Observable Applicable passageways for air distribution 1❑Not systems are sealed in accordance with; the applicable criteria of this section 1 ; and Table C403.2.9.2. C403.2.9. 4 Cavities in framed spaces are not 1❑Complies used to deliver air from or return air to ❑Does NoY� ; Exception: Requirement does not apply. [ME78]2 the conditioning system unless they ❑Not Observable contain an air duct insert which is insulated in accordance with Section ❑Not Applicable C403.2.9.1 and constructed and sealed in accordance with the requirements of Section C403.2.9.2 1 appropriate for the duct materials used. C403.2.9. JAir distribution systems are sized and 1❑Complie ;Requirement will be met. 5 designed in accordance with UDoes No [ME76]z recognized engineering standards. 1❑Not Observable; Refer to section details. , ❑Not Applicable C403.2.9. Air -handling units not installed in ;❑Complies ; Requirement will be met. attics of commercial buildings. ;❑Does Not 2 [ME77] ;❑Not Observable ❑Not Applicable C408.2.2. lAir system balancing accomplished in 1❑Complies :Requirement will be met. 1 , a manner to first minimize throttling IF -]Does Noi [ME53]3 losses, then for fans with fan system ; Observable power greater than 1 hp, fan speeds ;❑Not shall be adjusted to meet design flow 1❑Not Applicable , ; !be conditions. Balancing procedures shall i in accordance with NEBB Procedural Standards, the AABC, 1 ; National Standards, or equivalent procedures. C403.2.6. I Demand control ventilation provided ;❑Complie� :Requirement will be met. 1 Ifor spaces >500 ft2 and >25 1❑Does Not [ME59]1 I people/1000 ft2 occupant density and ;❑Not Observable ,served by systems with air side , (economizer, auto modulating outside 1❑Not Applicable ; I air damper control, or design airflow '>3,000 cfm. C403.2.6. ; Enclosed parking garage ventilation ;❑Complies ;Exception: Requirement does not apply. 2 !has automatic contaminant detection UDoes Not [ME115]3 land capacity to stage or modulate 1❑Not Observable )fans to 50% or less of design capacity. 1❑Not Applicable ; C403.2.7 I Exhaust air energy recovery on 1❑Complies :Exception: Requirement does not apply. [ME57]1 Isystems meeting Table C403.2.7(1) I❑Does Not I and C403.2.7(2). I ❑Not Observable 1 1❑Not Applicable ; C403.2.8 11 Kitchen exhaust systems comply with 1❑Complies ;Requirement will be met. [ME116]3 i replacement air and conditioned 1❑Does Not 1 i1supply air limitations, and satisfy hood 1 1 Observable I rating requirements and maximum ;❑Not !exhaust rate criteria. 1❑Not Applicable ; C403.4.4. I Multiple zone VAV systems with DDC '❑Complies Exception: Requirement does not apply. 6 lof individual zone boxes have static 1❑Does Not 1 [ME110]3 l pressure setpoint reset controls. II See the Mechanical Systems list for values. I I❑Not Observable { 1❑Not Applicable 1 1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Popeyes Ft Pierce, FL I Report date: 12/05/18' Data filename: Page 14 of 23 Section # Mechanical Rough -In Inspection Complil s? Comments/Assumptions & Req.ID C408.2.2. Air outlets and zone terminal devices❑Complie :Requirement will be met. 1 j have means for air balancing. E❑Does No [ME53]3 fI ❑Not Obs rvable ; ;❑Not Applicable C403.5, Refrigerated display cases, walk-in ;❑Complies ; Requirement will be met. C403.5.1, coolers or walk-in freezers served by ❑Does Not C403.5.2 [ME123]3 remote compressors and remote I (condensers not located in a I ❑Not Observable, condensing unit, have fan -powered :❑Not Applicable condensers that comply with Sections C403.5.1 and refrigeration compressor; ; systems that comply with C403.5.2.. I C403.5.3 Condensing coils installed in cool air ;[]Complies[; Requirement will be met. [ME124]3 stream of another air-conditioning I❑Does No unit. The condensing coil of one air- 1❑Not conditioning unit shall not be installed Obs rvable ; in the cool air stream of another air- :❑Not Applicable conditioning unit. i Section # Rough -In Electrical' Inspection Complies? Comments/Assumptions & Req.ID C405.2.1 I Lighting controls installed to uniformly ;❑Complies :Requirement will be met. [EL15]1 reduce the lighting load.by at least :❑Does Notl t50% :❑Not Observable ; ❑Not Applicable C405.2.1 [EL18]1 ;Occupancy sensors installed in ;❑Complied !required spaces. ;❑Does ;Requirement will be met. No f ;❑Not Obs rvable: ❑Not Applicable C405.2.1, Independent lighting controls installed 1❑Complie� :Requirement will be met. C405.2.2. per approved lighting plans and all I❑Does Not 3 [EL23]z manual controls readily accessible and; visible to occupants. :❑Not Observable :❑Not 1 Appl cable 1 , C405.2.2. Automatic controls to shut off all I❑Complies I Requirement will be met. 1 building lighting installed in all :❑Does Noy I [EL22]2 buildings. 1 E❑Not I Observable :❑Not Applicable 1 C405.2.3 Daylight zones provided with 1❑Complies ; Exception: Requirement does not apply. [EL16]2 individual controls that control the ;❑Does Not lights independent of general area lighting. :❑Not I Observable :❑Not Applicable : C405.2.3, C405.2.3. I Primary sidelighted areas are ;❑Complie' :Exception: Requirement does not apply. 'equipped with required lighting ;❑Does Not 1, C405.2.3. 2 :controls. I I❑Not Observable: :❑Not Applicable [EL20]1 1 ! 1 " I ' C405.2.3, Enclosed spaces with daylight area 1❑Complie'Is :Exception: Requirement does not apply. "under C405.2.3. skylights and rooftop monitors ❑Does Not 1, 'controls. `are equipped with required lighting I❑Not Observable: C405.2.3. 3 1 iervablel :❑Not Applicable 1 [EL21]1 ' ' C405.2.4 Separate lighting control devices for :❑Complies ;'Requirement will be met. [EL4]1 ispecific uses installed per approved 1❑Does Not I lighting plans. I :❑Not Observable: I I ❑Not Applicable C405.2.4 Additional interior lighting power :❑Complies :Requirement will be met. [EL8]1 l allowed for special functions per the 1❑Does Not approved lighting plans and is I :❑Not Observable: automatically controlled and separated from general lighting. t]Not Applicable C405.2.5 ;Automatic [EL25]nu!l lighting controls for exterior:❑Complies ;Requirement will be met. lighting installed. Controls will be 1❑Does Not I !daylight controlled, set based on I I I business operation time -of -day, or UNot Observable reduce connected lighting > 30%. :❑Not Applicable 1 C405.3 Exit signs do not exceed 5 watts per :❑Complies I Requirement will be met. [EL6]1 :face. ;❑Does Not :1-]Not Observable: I❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 3 1 Low impact (Tier 3) Project Title: Popeyes Ft Pierce, FL I Report date: 12/05/18 Data filename: Page 16 of 23 # Insulation Inspection Complies? Comments/Assumptions &'Req.ID C303.1 !Roof insulation installed per ;❑Complies :Requirement will be met. [IN3]1 manufacturer's instructions. Blown or :❑Does No 1poured loose -fill insulation is installed only where the roof slope is <=3 in ;❑Not Observable , 12. ;❑Not Applicable ; C303.1 Building envelope insulation is labeled ;❑Complies :Requirement will be met. [IN10]2 with R-value or insulation certificate j❑Does Nol providing R-value and other relevant I Observable ; data. :❑Not i ❑Not Applicable C303.2 Above -grade wall insulation installed ;❑Complie :Requirement will be met. [IN7]1 ; per manufacturer's instructions. ;❑Does Ndt E :❑Not I :Location on plans/spec: NA Observable I !❑Not , Applicable C303.2.1 Exterior insulation is protected from ;❑Compli [IN14]2 damage with a protective material. :❑Does N Verification for exposed foundation ❑Not Ob. insulation may need to occur during Api Foundation Inspection. ;❑Not C402.2.1 Insulation intended to meet the roof ;❑Compli, [IN17]3 insulation requirements cannot be E❑Does N installed on top of a suspended :❑Not Ob: ceiling. Mark this requirement compliant if insulation is installed I❑Not Apl accordingly. C402.2.3 Above -grade wall insulation R-value. I❑Complii [IN6]1 I ;❑Does N I❑Not Ob ❑Not ApJ C402.2.5 Floor insulation R-value. ;❑Compli1 [IN8]2 ;❑Does N :[:]Not Ob! C402.2.6 !Radiant panels and associated {components, ;❑Coml [IN18]3 designed for heat :❑Does transfer from the panel surfaces to the � occupants or indoor space are Not C insulated with a minimum of R-3.5. I❑Not A C402.3 High-albedo roofs satisfy one of the ;❑Coml [IN5]3 following: 3-year-aged solar ;❑Does reflectance >= 0.55 and thermal UNot C emittance >= 0.75 or 3-year-aged A solar reflectance index >= 64.0. ;❑Not C402.2.2 ;Roof R-value. For some ceiling ;❑Coml [IN2]1 (systems, verification may need to :❑Does _ Ioccur during Framing Inspection. I ;-]Not C ❑Not A C402.5.1. !All sources of air leakage in the ;❑Comr 1 i building thermal envelope are sealed, :❑Does [I111]1 caulked, gasketed, weather stripped ;❑Not C or wrapped with moisture vapor - permeable wrapping material to ;❑Not A minimize air leakage. , Additional Comments/Assumptions: h Impact (Tier 1) :Exception: Requirement does not apply. I able ble ervable licable ble ;Requirement will be met. See the Envelope Assemblies table for values. See the Envelope Assemblies table for values. , ervable licable ; s ;Exception: Requirement does not apply. of servable; Acable as ;Requirement will be met. hservable ;plicable ies ;See the Envelope Assemblies table for values Jot )servable I iplicable ies :Requirement will be met. lot ;servable plicable um Impact (Tier 2) 13 1Low Impact (Tier Project Title: Popeyes Ft Pierce, FL I Report date: 12/05/18 Data filename: Page 18 of 23 Section # Final Inspection Compli gI s7' Comments/Assumptions & Req,ID C303.3, Furnished O&M instructions for ;❑Complies :Requirement will be met. C408.2.5. systems and equipment to the ❑Does No 2 [FI17]3 building owner or designated representative. :[--]Not Observable ❑Not Appl cable C303.3, !Furnished O&M manuals for HVAC ;❑Complies :Requirement will be met. C408.2.5. Isystems within 90 days of system :❑Does Not [FI8]3 !acceptance. :❑Not Observable f ;❑Not Applicable ; C403.2.4. Minimum one humidity control device ,[]Complies :Requirement will be met. 2.4 per installed I❑Does Not [FI5613 humidification/dehumidification I❑Not I Observable system. Controls prevent ;❑Not simultaneous operation of Applicable humidification and dehumidification I I equipment. ' C402.5.3 I Where open combustion air ducts ;❑Complies !Exception: Requirement is not applicable. [F[51]3 ! provide combustion air to open I❑Does lyot {combustion fuel burning appliances, Ithe appliances and combustion air ;❑Not ' Observable opening are located outside the ;❑Not Applicable building thermal envelope or enclosed in a room, isolated from inside the ; thermal envelope. Such rooms are sealed and insulated. ; C402.5.6 I Weatherseals installed on all loading 10Comp ies :Exception: Requirement does not apply. [FI37]1 (dock cargo doors. ;❑Does of ❑Not O servable ❑Not Applicable C402.5.8 Recessed luminaires in thermal I❑Complies :Exception: Requirement does not apply. [FI26]3 envelope to limit infiltration and be IC I❑Does iI rated and labeled. Seal between interior finish and luminaire housing. ;❑Not Observable I❑Not Applicable 1 C403.2.1 { HVAC systems and equipment design I❑Complies :Requirement will be met. [FI50]3 I loads calculated in accordance with !❑DoeslNot ANSI/ASHRAE/ACCA Standard 183 or ACCA Manual N or by an approved UNot Observable equivalent computational procedure. ❑Not Applicable Design loads shall be attached to the ; code compliance form submitted to ; the building department when the building is permitted or, in the event the mechanical permit is obtained at a later time, the sizing calculation shall I be submitted with the application for the mechanical permit. ; C403.2.2 HVAC systems and equipment ;❑Complies ; Requirement will be met. [FI27]3 capacity does not exceed calculated :[--]Does Not loads. I❑Not Observable ❑Not Applicable C403.2.4. Heating and cooling to each zone is :❑Complies :Requirement will be met. 1 controlled by a thermostat control. ❑Does Not [FI47]3 Minimum one humidity control device ;❑Not Observable per installed humidification/dehumidification I❑Not Applicable j system. 1 1 1 High Impact (Tier 1)1 High Impact (Tier 1) 2�Medium Impact (Tier 2) 3 Low Impact (Tier 3)impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Popeyes Ft Pierce, FL I Report date: 12/05/18 Data filename: Page 19 of 23 Section #, Final Inspection Compli s? Comments/Assumptions & Req.ID C403.2.4. ,Thermostatic controls have a 5 °F :❑Complie :Requirement will be met. 1.2 1deadband. ;❑Does No [FI38] 3 ;❑Not Observable 1 ❑Not Applicable ; C403.2.4. JTemperature controls have setpoint ;❑Complie :Requirement will be met. 1.3 overlap restrictions. ❑Does No [FI20]3 ❑Not Observable: ❑Not Applicable C403.2.4. Each zone equipped with setback ;❑Compliers :Requirement will be met. 2 controls using automatic time clock or ;❑Does Not [FI39]3 programmable control system. ❑Not Observable : ❑Not Applicable C404.12.2 Public lavatory facilities equipped with ;❑Compliel's :Requirement will be met. [FI53]3 outlet devices which limit the flow of ❑Does Not f hot water to a maximum of 0.5 gpm or;❑Not Observable are equipped with self -closing valves ; , that limit delivery to a per cycle �❑Not Applicable maximum of 0.25 gallons of hot water !for recirculating systems and to a ; !maximum of 0.50 gallons for non- i recirculating systems. C404.12.2 Public lavatory water temperature ;❑Compli✓s ;Requirement will be met. [FI57]3 <=110°F. ;❑Does Not ❑Not Obl ervable ; ❑Not Applicable C404.12.1 [FI52]3 Showers used for non -safety reasons ;❑Compliees : Exception: Requirement does not apply, equipped with flow control devices to :❑Does Not limit the water discharge to a ;❑Not Observable maximum of 2.5 gpm per shower head. Flow restricting inserts used as ;❑Not Applicable i a component part of a showerhead ;are mechanically retained at the point ; ; of manufacture : C408.2.2 Construction documents require that a:❑Complies :Requirement will be met. [FI54]3 written balance report be provided to ;❑Does Not the building owner or rep for HVAC ❑Not Observable systems serving zones with total I , condition area > 5,000 sgft. Air :❑Not Applicable distribution systems shall be tested, adjusted, and balanced by a licensed : engineer or certified company. C403.2.4. Automatic Controls: Setback to 55°F :❑Comp ies :Requirement will be met. 2.1, i (heat) and 85°F (cool); 7-day clock, 2- :❑Does Not C403.2.4. !hour occupant override, 10-hour �❑Not 0 servable 2.2 !1 [F[40]3 E backup ;❑Not Applicable ; If ; C403.2.4. `Systems include optimum start ;❑Complies ;Exception: Requirement does not apply. 2.3 Econtrols. ;❑DoeslNot [F141]3 I ;❑Not Observable ; E ;❑Not applicable C404.3 ; [FI11]3 ;discharge Heat traps installed on supply and ;❑Complies ;Exception: Requirement does not apply. piping of non -circulating ❑DoeslNot systems. ;ONot Observable ; ❑Not Applicable 11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Popeyes Ft Pierce, FL I Report date: 12/05/18 Data filename: Page 20 of 23 Section # IFinal Inspection Compli's? Comments/Assumptions & Req.ID . I C404.4 piping insulated in accordance with ;❑Complies !Requirement will be met. [FI25]2 section details and Table C403.2.10. 1❑Does Not JAll ❑Not Observable ❑Not Applicable C404.6.1 Controls are installed that limit the ;❑Complies ;Requirement will be met. [FI12]3 operation of a recirculation pump 1ODoes Not installed to maintain temperature of a :❑Not storage tank. System return pipe is a Observable dedicated return pipe or a cold water ;❑Not Applicable ; supply pipe. C405.4.1 [FI18]1 ; Interior installed lamp and fixture ;❑Complies (lighting power is consistent with what ;❑Does ;See the Interior Lighting fixture schedule for values. Not is shown on the approved lighting (plans, demonstrating proposed watts ;❑Not I Observable; Applicable are less than or equal to allowed ;❑Not watts. I C405.5.1 !Exterior lighting power is consistent ;❑Complies ;See the Exterior Lighting fixture schedule for values. [FI19]1 with what is shown on the approved :❑Does Iyof i lighting plans, demonstrating I proposed watts are less than or equal :[:]Not Observable Ito allowed watts. ;❑Not Applicable ; C408.2.1 lCommissioning plan developed by ;❑Comp ies :Requirement will be met. [F128]1 I registered design professional or ❑Does �ot { approved agency. ❑Not 0 servable ; ;❑Not Applicable ; C408.2.3. ; 1 ,ensure HVAC equipment has been tested to ;❑Complies ; Exception: Unitary or packaged HVAC eqiupment without proper operation. ;❑DoeslNot :supply air [FI31]1 economizers. ;❑Not Observable ❑Not Applicable C408.2.3. HVAC control systems have been ;❑Complies :Requirement will be met. 2 nested to ensure proper operation, ❑Does Not [FI10]1 (calibration and adjustment of controls. ❑Not Observable ; ❑Not Applicable C408.2.4 !Preliminary commissioning report ;❑Complies ; Requirement will be met. [F129]1 !completed and certified by registered ❑Does Not ;design professional or approved I :❑Not Observable !agency. ;❑NotlApplicable ; C408.2.5. Furnished HVAC as -built drawings ;❑Complies :Requirement will be met. 1 (submitted within 90 days of system ;❑Does Not [FI7]3 ,acceptance. i I :❑Not' Observable Ii f ;❑Not Applicable ; C408.2.5. Furnished as -built drawings for ;❑Co plies ;Requirement will be met. 1 electric power systems within 90 days ;❑Does Not [FI16]3 of system acceptance. I ;❑Not Observable; ❑Noi Applicable C408.2.5. I An air and/or hydronic system ;❑Complies :Requirement will be met. ba 3 lancing report is provided for HVAC Does Not i ;❑ [FI43]1 j, systems. ;❑Not Observable: I ;❑Ndt Applicable C408.2.5. :Final commissioning report due to ;❑Complies ; Requirement will be met. 4 building owner within 90 days of ;❑Does Not [F130]1 I receipt of certificate of occupancy. ❑Not Observable I ;❑Not Applicable Project Title: Popeyes Ft Pierce, FL Data filename: (Tier 1) 2 Medium Impact (Tier 2) 3 I Low Impact (Tier 3) Report date: 12/05/18 Page 21 of 23 ft # Final Inspection & Req.ID C408.3 Lighting systems have been tested to [FI3311 ensure proper calibration, adjustment, programming, and operation. Additional Comments/Assumptions: 1 I High Impact (Tier 1) Project Title: Popeyes Ft Pierce, FL Data filename: Comments/Assumptions iplies :Requirement will be met. s Not Observable: . Applicable ; Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) J Report date: 12/05/18 Page 22 of 23