Loading...
HomeMy WebLinkAboutPLAN REVIEW FORMSAINT LUCIE COUNTY FIRE DISTRICT PLAN REVIEW FORM t 5160 N.W. Milner Drive. Port Saint Lucie, FL 34983 Telephone:772-621-3322 Fax: 772-621-3604 Web Address: www.sidd.com Building Dept. SLC FMO Permit # B-19-225 Project Name Popeyes Chicken `- BLDG Permit# 1902-0085 Address 4946 South 25th Street City Ft Pierce Contractor Venture Construction y � A ddress 3085 Stage Post Drive ate 1 City Memphis - State FL Zip3II133 Telephone (901) 372-5766 Architect/Engineer LISArchitecture S��_ Telephone (321)693-9244 Occupancy Type FBT.iress Construction Type F Square Feet 2265 Occuwnt Load f 54perplarls Number of Stories 1 Access Box Required Access Key Switch AFS Permit FA Permit Required FFPPermlt Required i General Notes 1. An electronic copy of the construction documents submitted on a CD is required. The file format shall be .pdf only. 2. All revisions, including the electronic copy must be received prior to permitting. 3. The Fire Marshal requires 24 hour notice on all inspections. 4. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 5. Failed inspections require payment of fee prior to rescheduling of further inspections. 6. Penetrations through rated assemblies shall he of the proper UL design. Design criteria shall be submitted with the construction plans. 7. Fire alarm panels shall be located indoors within air conditioned space. 8. Plans and construction are subject to corrections in the field to maintain code compliance. 9. Automatic fan shutdown Is required for HVAC system/s that exceed 2,000 cfm design capacity. 10. The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection Systems require a separate review and permit. THE FLORIDA FIRE PREVENTION CODE, 2015 EDITION IS CURRENTLY ENFORCED. BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL BE (MARKED WITH APPROVED FIREFIGHTER SAFETY WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY, See General Notes Above and Required Revisions Below 1 Automatic fan shutdown is required for HVhC sy�tam/s that exceed 2,0001 cfm design.6pacity. Provide a remote test and inspect appliance equipped with ar. audible/visual indicator for each HVAC duct smoke detector. HVAC duct smoke detector(s) shall be tied into the fire 3larhl-system: 2. The Installation Qf a Rre Alarm nr Fixed Fire Protection Systems rk11Are a separate review and permit. Page F of'iRevieNe�l!2y lTonyi&gr_r Date 08-07-2019