BUILDING PLAN PAGE 1-8
.3*B-500 00 GPM Grease Interceptor for Indoor/ Outdoor Use lU%a" (27 cm) 37" .4 1/2" I I (94 cm) 126 cm) 39" (99 cm} 94Y4" ' 46" (239 cm) (rn cn)� Grease Interceptor Calculations FPC 1003.4 "Size in accordance with PDT-3101" PDI-G101, Table 8.3,1 Step One „ Flow Rate / Fixture Capacity 3-Comp Sink 18" X 24" X 18" X 3 comps = 23,328 cu in 1-Comp Prep Sink 18" X 24" X 18 = 7,716 cu in Map Sink 24" X 24" X 10" = 5,760 cu in Total = 36,864 cu in / 231 X 0.75 = 120 / 2 min = 60 GPM Step Two - Grease Production 600 meals/day 0.035 lbs/meal - High Grease ina. ffatware) 90 days per pump -out cycle 90-Day Grease Production = 600 meals/day X 0.035 Ibs/meal X 90 days = 1,890lbs. DESCRIPTION Polyethylene Greasc InL&N L�PLO MODEL NUMBER: Flow Rates/ Grease Capacities: 100GPM /3,04f lbs. B. 0 Liquid Capacity:a10 g,;iI 15 OPTIONAL HYDROMECHANICAL GREASE TRAP P4 NTS „A" TOP VIEW 24" HEAVY DUTY CAST- IRON FRAME & COVER WITH "GASTIGHT" GASKET - STANDARD. 4" INLET & OUTLET PIP AND FITTINGS STANDARD RISERS AS READ. W Z J 5i m Q ....»:.. INVERT , Rif SECTION G.T. SIZE DIM "AA DIM. 1200 GALLON 8 -2 5 1 GREASE LOAD CALCULATION S = TOTAL SEATS GS = GALLONS OF WASTE WATER PER SEATS HR = HOURS OF OPERATION LF = LOADING FACTOR M = DRIVE THRU MEALS PER DAY GM = GALLONS PER MEAL (S) x (GS) x (LF) - (25%) = EFFECTIVE SEATING CAPACITY IN GALLONS (46) x (10) x (12/12) x (1) x (0.75) = 345 GALLONS PLUS (M) X (GM) X (LF) = EFFECTIVE TAKE OUT MEAL IN GALLONS (150) X (5) X (1.0) = 750 GALLONS TOTAL = (345) + (750) = 1095 GALLONS USE 1250 GALLONS 13 GREASE TRAP DETAIL P4 NTS BALL VALVE — THERMOMETER 110* TEMPERED WATER TO PLUMBING FIXTURES 140" HW SUPPLY -------------------- PROVIDE 2FT. MIN. HEAT TRAP Og IF NOT PROVIDED AT HEATER i OR IF VALVE IS LOCATED AWAY I 2'MIN. FROM HEATER. __J i COLD WATER SUPPLY ---------- ---------�I--_j CHECK VALVE DETAIL NOTES: 1. 2. SEE PLANS FOR HW SIZES FROM WATER HEATER SYSTEM TO MIXING VALVE ASSEMBLY. REDUCE AT ASSEMBLY AS REQUIRED. 3. INSTALL PER MANUFACTURERS PUBLISHED RECOMMENDATIONS. 14 THERMOSTATIC MIXING VALVE P4 NTS SECURE PIPING TO WALL 3/4" CW INLET AT 8'-4" AFF 10 III n WATER HAMMER ARRESTOR- CW PIPING TO PRESSURE REDUCING JOSAM NO. 75003 ABOVE CEILING VALVE- WATTS OR EQUIVALENT NO. U5B SET 80 PSI MAX------_ iC ACCESS DOOR FOR MAIN SHUT-OFF HALLMANN SALES, LLC #DSC-214M 12x12 I I MAIN SHUT-OFF BALL VALVE w I ELECTRICAL GROUNDING CONNECTION > I PER NEC SECTION 250 io GRND `t z PIPE SLEEVE TO BE ONE PIPE a SIZE LARGER THAN PIPE. SEAL FINISHED FLOOR d ONLY WITH APPROVED CAULKING COLD WATER SERVICE TYPE SLEEVE TO BE PVC SCH. 40 "L" COPPER, SOFT TEMPER AND SHALL EXTEND 1/2" FLO ABOVE SLAB (TYPICAL) 10 COLD WATER SERVICE ENTRANCE P4 , NTS HW TO BUILDING THERMOMETER T & P RELIEF VALVE - RUN RELIEF VALVE PIPING TO FLOOR DRAIN EWH-1 DRAIN VALVE WITH HOSE THREADS WATER HEATER — ELECTRIC WATER HEATER DETAIL NTS FW TO DRINK SYSTEM Tf F—, ;-1 1- FW TOICE 1 , MAKER AND MF COFFEE MAKER BALL 1— VALVE (TYP) UNION (TYP) / 12 � WATER FILTER DETAIL P4) NTS �8 NOT USED �P4 NTS ING PE r 7 \ GREASE RECOVERY CONNECTION P4 NTS co R S PVC WYE (WYE WITH REDUCING BRANCH IF MAIN IS OVER 4') iINK PVC BEND FULL SIZE, 4" MAX. PLUG IF END OF LINE FLOW 3/4" HWR s FLOOR SINK 1" CW SUPPLY P4 NTS RECIRCULATING PUMP TO BE CONTROLLED BY AQUASTAT BALL VALVE TO BALANCE SYSTEM. MUST BE DOWNSTREAM OF PUMP 3 COMPARTMENT SINK 0 -EXPANSION TANK o Q WATTS DET-5 0 1-0 c� - (V W x -FLOOR z Y �g 2" DRAIN LINESJ�� 2" TO INDIRECT CONNECTION TO 5 3 COMPARTMENT SINK P4 NTS STRAINER, FLUSH WITH FLOOR — WATERPROOF MEMBRANE MEMBRANE FLASHING FLANGE DRAIN SUPPORT STRAP DISCHARGE PIPE SCHEDULE40 PVC W/REDUCER ( SIZE AS INDICATED ON DRAWINGS — Al 4 FLOOR DRAIN P4 NTS �i 3 HUB DRAIN P4 NTS FLUSH COVER FIN. FLOOR CLEANOUT PLUG AND BODY, SEE SPECS. PVC WYE (WYE WITH REDUCING BRANCH IF MAIN IS OVER 4') ------ ADJUSTABLE DRAIN HEAD TILE FLOOR AIR GAP =2X "D" OR 2" MIN. 4" ( UNLESS OTHERWISE NOTED RIPLANS) FLOOR SLAB I ADJUSTING COLLAR PVC RISER PVC BEND /—FULL SIZE, 4" MAX. PLUG IF END OF LINE FLO — FLOOR CLEAN -OUT C P4 ) NTS FLUSH HEAVY DUTY CAST IRON 0 w U O LU w w m O O Z W Of 2 W 2 H W U Z W OD Z N W W 2 H z H Z W C) O 0 W W 2 H O H H 2 CD W 0- 0 a w 2 t- O J 0 Z Q F- 2 c� m M � Obi Li.l Ow(O� Q1 E > M M (� �' I N Q VZ o o 0.E I— M O E N w i— LLJ Z U (D Q LU J O J m � J w M rn w Z W ( 0 z �z z mwoa' W > N O U c .� ,NM.. z o No 4i E ¢ ¢ �c'nari U Z LU Q o J m U) W 0- LU _I 2 U N M Q LL ] W 1— O 1— y �a z Q L LU J i 2 Z:)� O � LU 2 H 0 O IpopeYesl Z LU o J_ Q U) LU J Z W V~ L6 CV L in Of W c 0 a 0— J o i K a ,r SEAL 0 W6 a 6 2018 HN_ ! �.�`pOEFlOq ... Q > III No 4 43 of LU Uj 2 7331: : >_ .44/ :O <4: •0S . 4 O R 1 U)1 LU l '��iLQi�j�(614s9E X ( FLO NA'A #44643 Whli•. W. 4v tV,a :. .ss.. ... P ;4. •FG:.P ..uu. as RELEASE DATE 2 3 I" 5 tr s PROJECT NO. 2018-002 3i jl I�4P{,.n�NR�n::.nv, ,.i..:_�:dn �..:Pi+Ai TylP aili..}IGIIGu'i •in I..a.t 4M.i. r ISSUE DATE III 12/21/18 DRAWN CHECKED -1 ELECTRICAL SPECIFICATIONS DIVISION 16 - ELECTRICAL SPECIFICATIONS PART I. GENERAL PROVISIONS 1. SCOPE: PROVIDE ALL LABOR, MATERIAL, AND EQUIPMENT IN ACCORDANCE WITH THESE SPECIFICATIONS, AND THE ACCOMPANYING DRAWINGS TO PROVIDE A COMPLETE AND PROPERLY OPERATING ELECTRICAL SYSTEM FOR THE BUILDING. A. THE CONT RACTOR SHALL FURNISH AND INSTALL ALL OF THE FOLLOWING MATERIAL AND EQUIPMENT UNDER THIS DIVISION OF THE SPECIFICATIONS, UNLESS NOTED OTHERWISE: PANELBOARDS; LIGHTING FIXTURES; LAMPS; RACEWAYS; 600 VOLT WIRE AND CABLE; WIRING DEVICES; DEVICE PLATES; DEVICE, PULL, AND JUNCTION BOXES; SAFETY SWITCHES; MOTOR STARTERS; LIGHTING CONTROLS; CIRCUIT BREAKERS; FUSES; TIME CLOCKS; EQUIPMENT IDENTIFICATION (NAMEPLATES AND DIRECTORIES); WIRE AND CABLE TERMINATIONS; CONNECTIONS TO INDIVIDUAL UNITS OF EQUIPMENT FOR THE WALK-IN FREEZERS AND COOLERS; AND TEMPORARY POWER. B. THE FOLLOWING MATERIAL AND EQUIPMENT WILL BE FURNISHED AND/OR INSTALLED BY OTHERS, OR UNDER OTHER DIVISIONS OF THE SPECIFICATIONS, UNLESS NOTED OTHERWISE: LOW VOLTAGE 24 VOLT WIRE AND CABLE , COMMUNICATION DEVICES SECURITY ( ) CU ITY EQUIPMENT, POINT OF SALE (POS) EQUIPMENT, SIGNAGE, CONCRETE BASES FOR SITE LIGHTING POLES. C. THE FOLLOWING MATERIAL AND EQUIPMENT WILL BE FURNISHED BY OTHERS, OR UNDER OTHER DIVISIONS OF THE SPECIFICATIONS, AND INSTALLED BY THE CONTRACTOR, UNLESS NOTED OTHERWISE: SITE LIGHTING FIXTURES AND POLES. 2. GENERAL REQUIREMENTS: ALL WORK SHALL BE PERFORMED BY SKILLED LICENSED ELECTRICIANS IN ACCORDANCE WITH THE BEST PRACTICES OF THE TRADE, MEETING THE REQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE 2011 EDITION, APPLICABLE FEDERAL, STATE AND LOCAL CODES, AND THE REQUIREMENTS OF THE ELECTRICAL UTILITY COMPANY FURNISHING THE SERVICES. ALL NECESSARY CONSTRUCTION PERMITS AND CERTIFICATES OF INSPECTION SHALL BE PURCHASED AND OBTAINED UNDER THIS CONTRACT. A. COORDINATION: ALL OUTLETS MUST BE ACCURATELY LOCATED, PARTICULARLY APPLIANCE OUTLETS WHICH SHALL BE LOCATED FROM THE DIMENSIONS GIVEN ON THE DRAWING AND FIELD VERIFIED. REVIEW THE ARCHITECTURAL, PLUMBING AND HEATING AND VENTILATING PLANS IN ORDER TO COORDINATE THIS WORK WITH OTHER TRADES, AND COOPERATE WITH THEM IN THE ENTIRE INSTALLATION. 3. SERVICE VOLTAGE: THESE DRAWINGS ARE FOR A METERED, UNDERGROUND BUILDI NG SERVICE OF 120/208 VOLT, THREE PHASE, FOUR WIRE, 60 HERTZ. ALL KITCHEN AND AIR CONDITIONING EQUIPMENT HAS BEEN DESIGNED AND PURCHASED FOR USE ON THIS ELECTRICAL SYSTEM. THE CONTRACTOR SHALL CONTACT THE ELECTRICAL UTILITY AND VERIFY ALL OF THE ABOVE SERVICE CHARACTERISTICS, AND THE AVAILABLE FAULT CURRENT. 4. SERVICE EQUIPMENT: THE SERVICE SHALL BE LOCATED AS SHOWN ON THE SITE PLAN, OR AS INDICATED IN THE INSTRUCTIONS TO BIDDERS. UTILITY POLES, PADS FOR UTILITY TRANSFORMERS, CURRENT TRANSFORMER ENCLOSURES, METERING EQUIPMENT, SERVICE MASTS, AND OTHER RELATED MATERIALS AND EQUIPMENT SHALL BE APPROVED, FURNISHED, AND INSTALLED AS REQUIRED. INCLUDE THE COST OF ALL THE ABOVE ITEMS, SERVICE CONNECTIONS, AND METER CHARGES IN THE BASE BID. MAIN SERVICE SWITCHES AND CURRENT TRANSFORMER CABINETS SHALL BE INCLUDED IN THE BASE BID. UNLESS NOTED OTHERWISE, A MAIN SERVICE SWITCH WITH CURRENT LIMITING FUSES MAY BE USED WHEN THE AVAILABLE FAULT CURRENT (AFC) IS EXCESSIVE, IN ORDER TO USE STOCK PANELBOARDS, WITH 1 OK OR 22K AIC RATINGS, PART II. MATERIALS 1. MATERIALS: ALL MATERIALS SHALL BE NEW AND OF THE QUALITY INDICATED BY THE SPECIFIED BRAND NAMES. SUBSTITUTIONS OF MATERIAL OF EQUAL QUALITY BY OTHER MAJOR MANUFACTURERS OF COMMERCIAL EQUIPMENT MAY BE ACCEPTABLE PROVIDED A LIST OF SUCH SUBSTITUTIONS IS APPROVED IN WRITING BY POPEYE'S ARCHITECTURE AND ENGINEERING DEPARTMENT. THE CONTRACTOR SHALL SUBMIT A SUBSTITUTION LIST IN TRIPLICATE AT LEAST FIVE DAYS PRIOR TO THE BID OPENING. A. PANELBOARDS: PANELBOARDS SHALL BE BOLT -IN CIRCUIT ELECTRICAL CODE. WHERE CONNECTIONS ARE TO BE MADE BREAKER TYPE, AS SHOWN ON THE PLANS. PANELS SHALL BE OF BETWEEN CONDUIT TERMINATIONS AND MOTORS, EQUIPMENT, OR PANELBOARD CONSTRUCTION, 20 INCHES WIDE (MINIMUM), 5-3/4" APPARATUS NECESSITATING FLEXIBLE CONNECTIONS, APPROVED TO 6-1/2" DEEP, UL LISTED, AND MEET UL 67, UL 50, AND FEDERAL FLEXIBLE CONDUIT SHALL BE USED. OUTDOOR CONNECTIONS TO SPECIFICATION C TION W-P-1158 AS TYPE 1, CLASS 1 WITH B - OLT ON FANS HVACUNITS OR ROTATING EQUIPMENT SHALL B MADE WITH CIRCUIT BREAKERS, COPPER BUS BARS, NEUTRAL BUS, GROUND HELICAL WOUND, LIQUID TIGHT, FLEXIBLE STEEL CONDUIT. BUS, AND A HINGED LOCKABLE DOOR. CABINETS SHALL BE CODE EXPOSED CONDUIT SHALL BE SUITABLY SUPPORTED AT GAUGE, GALVANIZED STEEL, MOUNTED AS SHOWN. PROVIDE INTERVALS NOT TO EXCEED FIVE (5) FEET. DURING TYPEWRITTEN CIRCUIT DIRECTORIES WITH CLEAR PLASTIC CONSTRUCTION, CONDUIT SHALL BE KEPT FREE OF ALL FOREIGN PROTECTORS IN ALL PANELS. ALL WIRES SHALL BE TAGGED WITH MATTER BY USE OF CAPPED BUSHINGS ON ALL TURNED UP ENDS. PANEL AND CIRCUIT NUMBERS. PANEL "MP" SHALL BE UL LISTED PAPER OR WOOD PLUGS ARE NOT ACCEPTABLE FOR THIS AND LABELED AS SUITABLE FOR USE AS SERVICE ENTRANCE PURPOSE. EQUIPMENT. APPROVED MANUFACTURERS OF PANELS ARE SQUARE D/TELEMECHANIQUE, CUTLER -HAMMER, GENERAL 7. WIRE AND CABLES: ALL WIRE AND CABLES SHALL BE ELECTRIC, WESTINGHOUSE, AND SIEMENS (1-T-E). UNDERWRITERS LABORATORIES' LISTED, AND LABELED, AND CONFORM WITH APPLICABLE STANDARDS OF UL (44, AND 83), B. LIGHTING FIXTURES: ALL LIGHTING FIXTURES SHALL BE UL LISTED, NEMA (WC-5, AND WC-7), IPCEA (S-61-402, AND S-66-524), FEDERAL COMMERCIAL QUALITY. REFER TO NATIONAL ACCOUNT SPECIFICATIONS (J-C-30A(1), AND HH-1-595C), ANSI, AND OTHER SCHEDULE. REVIEW AT: WWW.POPEYESDEVELOPMENT.COM; APPLICABLE INDUSTRY STANDARDS. CONNECTORS AND LUGS PASSWORD: lagniappe SHALL MEET UL PUBLICATION 486. ALL BRANCH CIRCUIT WIRING SHALL BE 600 VOLT, COPPER, 75 DEGREE C (MIN), TYPE C. LAMPS: ALL NEW FLUORESCENT IAMPS (F40T8) SHALL BE COOL THHN/THWN WITH A MINIMUM SIZE OF #12 AWG, UNLESS NOTED WHITE, OR COLOR IMPROVED COOL WHITE, WITH A 4100 DEGREE K OTHERWISE. WIRE SIZES OF #8 AWG AND LARGER SHALL BE COLOR TEMPERATURE, 2950 MIN INITIAL LUMENS, 20,000 HOURS STRANDED. SERVICE AND FEEDER CABLES SHALL BE 600 VOLT, RATED LIFE, AND 62 MIN CRI, UNLESS NOTED OTHERWISE. STRANDED COPPER, 75 DEGREE C (MIN), TYPE XHHW. ALL CIRCUITS SHALL HAVE A SEPARATE GROUND CONDUCTOR. D. WIRING DEVICES: ALL WIRING DEVICES SHALL BE UL LISTED, PROVIDE GREEN -INSULATED GROUND WIRE IN ALL RACEWAYS, COMMERCIAL SPECIFICATION GRADE. SWITCHES SHALL BE RATED CABLE ASSEMBLIES, AND WHERE NOTED. SIZE EQUIPMENT 20 AMPS AT 120/277 VOLTS, AC. STANDARD RECEPTACLES SHALL GROUNDS PER TABLE 250-122 OF THE NATIONAL ELECTRICAL BE 20 AMP, DUPLEX, GROUNDING TYPE, IN NEMA CODE. INSULATION COLOR CODES SHALL BE BLACK, RED, AND CONFIGURATIONS, UNLESS NOTED OTHERWISE. SWITCHES IN THE BLUE (PHASE), WHITE (NEUTRAL), AND GREEN (GROUND). SAME LOCATION SHALL BE GANGED BEHIND A SINGLE PLATE. DEVICE PLATES IN THE KITCHEN AREA SHALL BE METAL, A. ALL WIRING SHALL BE INSTALLED IN CONDUIT, EXCEPT WHERE ALUMINUM OR STAINLESS STEEL. DEVICE PLATES IN THE DINING SPECIFICALLY SHOWN ON THE DRAWINGS. NON-METALLIC AREA SHALL BE THERMOPLASTIC PLASTIC (NYLON) OR METAL, SHEATHED (TYPE NM) CABLE IS NOT PERMITTED. COLOR AS APPROVED BY THE ARCHITECT OR OWNER. APPROVED MANUFACTURERS OF SWITCHES AND RECEPTACLES ARE B. ALL BRANCH CIRCUIT, COMMUNICATION, SIGNALING, AND HUBBELL, ARROW HART, BRYANT, LEVITON, PASS & SEYMOUR, CONTROL WIRING TO KITCHEN, FIRE PROTECTION, AND OTHER GENERAL ELECTRIC, SLATER, OR EQUAL. EQUIPMENT SHALL BE ROUTED ABOVE THE CEILING. VERIFY WHETHER OR NOT THE SPACE ABOVE THE CEILING IS USED AS A 1. SWITCHES: SPACE FOR RETURN AIR FOR THE ENVIRONMENTAL AIR SYSTEM. a. SINGLE POLE: HUBBELL HBL1221-I, OR EQUAL. IF IT IS USED FOR RETURN AIR, PROVIDE APPROVED RACEWAYS b. THREE WAY: HUBBELL HBL1223-I, OR EQUAL. FOR ALL OVERHEAD WIRING PER NEC ARTICLE 300-22(8). IF IT IS 2. RECEPTACLES: NOT "OTHER SPACE USED FOR ENVIRONMENTAL AIR", APPROVED a. NEMA 5-20R: HUBBELL 53621, OR EQUAL. LOW VOLTAGE CABLES MEETING THE REQUIREMENTS OF NEC b. NEMA 5-20R-IG: HUBBELL IG-5362, OR EQUAL. ARTICLES 725 AND 760 MAY BE RUN WITHOUT RACEWAYS, LINO. c. NEMA 5-20R-IG/SS: HUBBELL IG-5362-OS, OREQUAL. ALL SAFETY CONTROL WIRING FOR FIRE PROTECTION SYSTEMS, d. NEMA 5-20R-GFCI: HUBBELL GF5362-1, OR EQUAL. SHUNT TRIPS, ETC. SHALL BE RUN IN A RACEWAY IN ACCORDANCE e. NEMA 6-20R: HUBBELL 5462-1, OR EQUAL. WITH NEC ARTICLES 725.25 AND 725.28. f. OTHERS: COMMERCIAL OR INDUSTRIAL GRADE, UL LISTED, FEDERAL SPECIFICATION WC596F, 8. SITE LIGHTING: THE G.C. WILL FURNISH THE SITE LIGHTING PACKAGE, AS REQUIRED FOR THE SPECIFIC LOCATION. UNDER 3. WP PLATES: WEATHERPROOF COVERS ARE PERMITTED UNDER THIS SPECIFICATION SECTION, PROVIDE 1" RIGID GALVANIZED NEC ARTICLE 406.8(B)(1). STEEL ELECTRICAL CONDUIT, AND THE REQUIRED WIRING FROM THE PANEL TO THE POLE. SET FIXTURES AND POLES ON 4. NATIONAL ACCOUNT: REFER TO THE NATIONAL ACCOUNT CONCRETE BASES, AS PROVIDED UNDER SPECIFICATION SECTION DIRECTORY. THE FOLLOWING EQUIPMENT MAY BE AVAILABLE: 3A: CONCRETE. GROUND/BOND ALL SITE LIGHTING MAIN SERVICE PANELBOARD WITH BREAKERS INSTALLED, FIXTURES/POLES PER THE NEC. THE BRANCH CIRCUIT LIGHTING AND DISTRIBUTION PANELBOARDS WITH BREAKERS CONDUCTORS SHALL BE INCREASED FROM #10 AWG TO #8 AWG IF INSTALLED, ROOF -TOP DISCONNECTS FOR HVAC UNITS AND THE HORIZONTAL DISTANCE FROM THE PANEL TO THE POLE IS KITCHEN HOOD FANS, LIGHTING CONTACTOR PANEL, AND SHUNT GREATER THAN EIGHTY (80) FEET. ALL SITE LIGHTING SHALL BE TRIP SYSTEMS (IF REQUIRED PER LOCAL CODE). CONTROLLED THROUGH THE LIGHTING CONTROL SYSTEM SHOWN ON THE DRAWINGS. REFER TO THE SITE PLAN FOR 5. EXCAVATIONS: PERFORM ALL NECESSARY EXCAVATING AND QUANTITY AND LOCATION OF ALL SITE LIGHTING. SET FIXTURES BACK -FILLING REQUIRED FOR THIS INSTALLATION. ALL AS SPECIFIED, AND AIM AFTER DARK FOR UNIFORM LIGHT EXCAVATIONS BELOW THE BOTTOM OF FOOTINGS SHALL BE DISTRIBUTION. BACKFILLED WITH 3000 PSI CONCRETE. WHERE DITCHES ARE CUT FOR OUTSIDE RUNS OF CONDUIT, REPLACE AND TAMP THE EARTH 9. SIGNAGE LIGHTING: PROVIDE A 1" RIGID GALVANIZED STEEL IN 12" LAYERS AND LEAVE THE GROUND LEVEL AND EQUAL TO ITS ELECTRICAL' CONDUIT, AND WIRING, FROM THE PANEL TO ALL ORIGINAL CONDITION. ILLUMINATED SIGNS AS SHOWN ON THE LIGHTING AND SITE PLANS. GROUND/BOND EACH SIGN. SIGNS WILL BE FURNISHED AND 6. CONDUITAND FITTINGS: CONDUIT PERMITTED: (A) RIGID INSTALLED BY THE OWNER, OR UNDER A SEPARATE CONTRACT, GALVANIZED STEEL (RGS), (B) EMT, (C) PVC, AND (D) ENT. TYPES UNO. POWER AND WIRING SHALL BE FURNISHED AND UTILIZED SHALL BE RUN ONLY AS PERMITTED PER CODE. ALL INSTALLED UNDER THIS SECTION OF THE SPECIFICATIONS. WIRING SHALL BE RUN IN CONDUIT. CONDUIT PLACED IN CONCRETE OR RUN UNDERGROUND SHALL BE RIGID GALVANIZED OTHER WIRING: CONDUIT OR PVC. IF PVC IS USED, ALL ELBOWS, SWEEPS AND STUB -UPS SHALL BE RGS. CONDUIT EXPOSED OR RUN IN A. FURNISH AND INSTALL ALL POWER WIRING AND CONDUIT AS MASONRY WALLS ABOVE GRADE MAY BE PVC OR EMT WHERE INDICATED ON THE DRAWINGS FOR ROOF -TOP HVAC EQUIPMENT, ALLOWED BY LOCAL CODES. IF EMT IS NOT PERMITTED, RIGID KITCHEN HOOD FANS, AND WALK-IN FREEZER AND COOLER SCREWED GALVANIZED PIPE CONDUIT AND FITTINGS SHALL BE EQUIPMENT. DISCONNECT SWITCHES, AVAILABLE FROM THE USED. IF SHIELDED CABLE IS REQUIRED FOR CONTROL NATIONAL ACCOUNT, SHALL BE FURNISHED AND INSTALLED FOR CIRCUITRY, IT SHALL BE TAN, GREY OR ANY NEUTRAL COLOR EACH UNIT OF HVAC EQUIPMENT, AND FOR KITCHEN EQUIPMENT OTHER THAN THAT AS SPECIFIED FOR POWER DISTRIBUTION. NO WITHOUT A CORD AND PLUG. BEFORE ENERGIZING ANY CONDUIT SMALLER THAN 3/4" SHALL BE INSTALLED EXCEPT FOR EQUIPMENT, VERIFY THAT THE CORRECT POWER SUPPLY TWO -WIRE SWITCH LEGS. ALL CONDUIT BENDS SHALL BE FREE VOLTAGE, AMPACITY, AND PHASING HAS BEEN PROVIDED AT THE FROM DENTS AND KINKS. ALL CONDUITS SHALL BE ELECTRICALLY LOAD SIDE OF THE DISCONNECT. CONTINUOUS FROM THE SERVICE EQUIPMENT TO ALL OUTLETS, AND SHALL BE SECURED TO ALL METAL BOXES WITH ONE LOCK B. FURNISH AND INSTALL THE LIGHTING CONTACTOR PANEL, AND ALL NUT OUTSIDE, AND ONE INSIDE THE BOX WITH A REINFORCED ASSOCIATED POWER WIRING, AS INDICATED. THE LIGHTING BAKELITE BUSHING. IF PVC, OR ENT, IS USED, THEN APPROPRIATE CONTACTOR PANEL IS CUSTOM BUILT, AND AVAILABLE FROM THE SIZED, ELECTRICALLY CONTINUOUS, BOND WIRES SHALL BE RUN NATIONAL ACCOUNT. FROM THE SERVICE EQUIPMENT TO ALL OUTLETS, AND SHALL BE SECURED TO EACH WIRING DEVICE PER THE NATIONAL 10. EMPTY CONDUIT: LEAVE A #12 AWG PULL WIRE IN ALL EMPTY CONDUITS. 11. BOXES AND WIREWAYS: ALL JUNCTION BOXES, PULL BOXES, WIREWAYS, ETC, SHALL BE SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE. 12. EQUIPMENT IDENTIFICATION: PROVIDE NAMEPLATES FOR ALL PANELBOARDS, CONTROLS, AND OTHER ELECTRICAL EQUIPMENT. EQUIPMENT VISIBLE TO THE PUBLIC SHALL BE IDENTIFIED WITH ENGRAVED LAMINATED NAMEPLATES ATTACHED WITH STAINLESS STEEL FASTENERS. ELECTRICAL EQUIPMENT NOT VISIBLE TO THE PUBLIC MAY BE NEATLY IDENTIFIED WITH BLACK PERMANENT MARKERS. PART III. EXECUTION 1. TESTS: MAKE ALL TESTS NECESSARY TO ENSURE THAT THE ENTIRE INSTALLATION IS FREE FROM IMPROPER GROUNDS, AND FROM SHORTED PEN CONDUCTORS. AND/OR 0 VOLTAGE, CURRENT, AND ROTATION TESTS SHALL BE MADE BEFORE ANY MOTORS ARE PLACED IN OPERATION. ALL LOADS SHALL BE BALANCED ACROSS PHASES. CHECK TO SEE THAT ALL LIGHTS WORK, AND ARE CONTROLLED BY SWITCHES INDICATED ON DRAWINGS, OR CIRCUIT BREAKERS SO INDICATED ON PANEL SCHEDULE. 2. GUARANTEE: FURNISH A GUARANTEE IN WRITING TO THE OWNER THAT ALL WORK EXECUTED UNDER THIS SECTION IS FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM DATE OF FINAL ACCEPTANCE, IN ADDITION, DURING THE TERM OF THIS GUARANTEE, THE REPAIR AND/OR REPLACEMENT OF ANY DEFECTIVE WORK, AND ALL RESULTING DAMAGES SHALL BE MADE AT NO ADDITIONAL EXPENSE TO THE OWNER. 3. TEMPORARY POWER: AT THE PROJECT SITE, PROVIDE A 100 AMP, 120/240 VOLT, SINGLE PHASE, SERVICE WITH POWER OUTLETS ADEQUATE FOR TEMPORARY CONSTRUCTION POWER. TEMPORARY LIGHTING SHALL BE MAINTAINED IN ALL AREAS OF THE BUILDING UNTIL PERMANENT POWER SOURCES HAVE BEEN ENERGIZED. TEMPORARY SERVICE SHALL BE PROVIDED UNDER SECTION 1A OF THESE SPECIFICATIONS. 4. CLEAN-UP: LEAVE THE ELECTRICAL PORTION OF THE WORK IN A CLEAN AND FINISHED CONDITION. 5. SHOP DRAWINGS: PROVIDE SHOP DRAWINGS FOR THE FOLLOWING ITEMS: PANELBOARDS, LIGHTING FIXTURES. 6. AS -BUILT DRAWINGS: MAINTAIN AS -BUILT DRAWINGS, UPDATED DAILY DURING CONSTRUCTION, AND PRESENT THE OWNER WITH ONE SET UPON COMPLETION. PROVIDE THE OWNER'S PERSONNEL WITH ON -SITE INSTRUCTION IN THE OPERATION AND MAINTENANCE OF THE COMPLETED ELECTRICAL SYSTEM. LEGEND ELECTRICAL SYMBOLS SINGLE FACE EXIT LIGHT W/EMERGENCY BATTERY PACK AND TWO (2) EMERGENCY LIGHT HEADS. SEE FIXTURE SCHEDULE n WP BRACKET OR WALL MOUNTED LIGHT FIXTURE. LETTER Y DENOTES MARK, SEE FIXTURE SCHEDULE. l_. CEILING MOUNTED EMERGENCY LIGHT FIXTURE o FLUORESCENT LIGHT FIXTURE. LETTER DENOTES MARK. SEE FIXTURE SCHEDULE. FLUORESCENT LIGHT FIXTURE ON NIGHT LIGHT CIRCUIT. FTI FLUORESCENT LIGHT FIXTURE. LETTER ODENOTES MARK. SEE FIXTURE SCHEDULE. O P PENDANT LIGHT FIXTURE. LETTER DENOTES MARK. SEE FIXTURE p SCHEDULE. ® RECESSED DOWN LIGHT FIXTURE. LETTER DENOTES MARK. SEE FIXTURE SCHEDULE. 8" VERTICAL FLUORESCENT RECESSED LIGHT FIXTURE. LETTER DENOTES MARK, SEE FIXTURE SCHEDULE. PF PADDLE FAN. LETTER DENOTES MARK. SEE FIXTURE SCHEDULE. lb TOGGLE SWITCH - SINGLE POLE - HUBBEL #HBL1221-I. 2¢":::Q DUPLEX RECEPTACLE; NUMBER SUBSCRIPT INDICATES MOUNTING HEIGHT ABV FINISHED FLOOR IF DIFFERENT THAN SPECIFIED. HUBBEL #5362-1 WP/GEIF DUPLEX RECEPTACLE - IN WEATHER PROOF ENCLOSURE —H OR COVER, GROUND FAULT INTERUPTER. —,4c RECEPTACLE FLUSH MOUNTED IN CEILING. --�— VERIFY EXACT LOCATION AND NEMA CONFIGURATION. IG DUPLEX RECEPTACLE - ISOLATED GROUND SURGE PROTECTED - HUBBELL #IG-5362-OSP FOR POS EQUIP. & PRINTERS I DUPLEX RECEPTACLE - ISOLATED GROUND SURGE C PROTECTED; MOUNTED IN CEILING. HUBBELL #IG-5362-OSP FOR MONITORS SPECIAL PURPOSE RECEPTACLE 2081120 PANELBOARD. DISCONNECT SWITCH SIZE AS NOTED. E j DOOR SWITCH MOUNTED IN DOOR FRAME (F.B.C.) 13 SEE ELECTRICAL NOTES. A.F.F. ABOVE FINISHED FLOOR. A. F. C. ABOVE FINISHED CEILING. F.B.C. FURNISHED BY CONTRACTOR. G.F.I. GROUND FAULT INTERUPTING W.P. WEATHERPROOF U.N.O. UNLESS NOTED OTHERWISE. A-3 CONDUIT RUN CONCEALED IN WALLS OR CL. SPACES. ARROWS _A/INDICATE HOMERUNS. SUBSCRIPT INDICATES PANEL AND CIRCUIT NUMBERS. SLASH MARKS INDICATE NUMBER OF CONDUCTORS. EQUIPMENT GROUNDING CONDUCTOR REQUIRED IN ALL CONDUITS NOT INDICATED WITH WITH - A-3 HASHMARK A / SAME AS ABOVE NOTE EXCEPT RUN CONDUIT BELOW FLOOR EF EXHAUST FAN. .©'SF SUPPLY FAN. *Y FF FLY FAN O JUNCTION OR OUTLET BOX. JUNCTION OBOXFOR SIGN -MOUNT SWITCH NEAR SIGN. MAKE ALL SIGN CONNECTIONS REQ'D. VERIFY ALL ASPECTS WITH SIGNAGE VENDOR. SEE ARCHITECTURAL ELEVATIONS FOR HEIGHT AND J LOCATION AS SHOWN. �SD JUNCTION BOX FOR SMOKE DETECTOR (F.B.C.) 120v 4 WIRING BY THIS CONTRACTOR. C COMBINATION DUAL DATA OUTLET AND TELEPHONE OUTLET HEIGHT AS NOTED ON PLANS WITH 3/4 " EMPTY CONDUIT TO ABOVE CEILING. PROVIDE PULL WIRE. TELEPHONE OUTLET, WALL TYPE, 24" AFF U.N.O ON PLANS WITH 3/4 " EMPTY CONDUIT TO ABOVE CEILING. PROVIDE PULL WIRE. DATA OUTLET, HEIGHT AS NOTED ON PLANS WITH 3/4 " EMPTY CONDUIT TO ABOVE CEILING, PROVIDE PULL WIRE. PROVIDE'ON/OFF' SELECTOR SWITCH AND PILOT LIGHT IN NEMA 4 STAINLESS STEEL ENCLOSURE MOUNTED ON THE FACE OF THE HOOD. PROVIDED BY HOOD MANUFACTURER. OSPEAKER; CEILING MOUNTED SPEAKER OUTLET IN WALL STUB 3/4" CONDUIT TO SPK SPACE ABOVE ACCESSIBLE CEILING, PROVIDE PULL WIRE. FTI TRANSFORMER MOUNTED ACCESSIBLE ELECTRIC DOOR PUSHBUTTON: EDWARDS #590 48" MOUNTING HEIGHT 1 B] ELECTRIC DOOR BUZZER: 8" BELOW CEILING PHOTOCELL REV COMPL rmo CODE gT. LU CC BOCC m N N W W ry E gf M M z E rN W W I— W = z z Q W J r � J m - uj J w U M �n � r z � LL o z r z Z ¢ m o w � C.J H H w p N 8 N N U z o M a o�hi E U Z N N u O a s U N j) 0 w U � O r a a w wi co !I U si z O Z � LLJ > J ¢ m _1 U) a F-- _ I i ¢ Lu U _I Q U w rn Z Lu W l r U � H �g Y w z 0 f' O = I— w w W 0 > 0 o cn 2 t5 Z co w''' U�/� O w rn w H D Q D D w O H W w w 0- O O J O a Q w w U F- F O W Q w zW CD LL Z N r- N w a ¢ = o a Y J N � � O 0D d SEAL O U LL U W W ui — W Q NU Of W W U) 0G�?, 6 2011 ,," OT W. Lig W s,`%% QO• V`G E N SF ,s� ✓�i > No 44 43 wcn = vs X RFLORICi� 4643 �, w RELEASE DATE I 2 3 4 s 6 PROJECT NO. 2018-002 r ISSUE DATE 12/21/18 gAWN CHECKED JC JC PANEL B-20 NOTE: REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, EXTERIOR ELEVATIONS AND WALL SECTIONS FOR DIMENSIONED LOCATIONS OF LIGHTING FIXTURES. ER L WP. LIGHTING CONTACTOR SEE DIAGRAM THIS SHEET & POWER RISER SHEET E3 PROGRAMMABLE TIMER 0 CLI �8 CL FBI /+_ L... 7e 7e I i 14 B-34 H b B-34 34 VIATIMECLOCK PROGRAMMABLE TIMER LOCATE LIGHTING AND FAN ON/OFF CONTROL SWITCHES "a, b, c, d & e" TO SPARE I AT THIS LOCATION MECHANICAL TIMER 2 HR. MAX OVERRIDE SWITCH �— 20A, 18 CHANNEL RELAY DINING LIGHTS PENDANT LIGHTSSIGN iCOUNTER/ RESTROOM LIGHTS KITCHEN LIGHTS SECURITY INTERFACE: SIGN BLDG FRT WIRE RUN TO SECURITY PANEL IN MANAGER'S OFFICE. LEAVE WIRE I MENU BOARD COILED ABOVE CEILING, DO NOT CONNECT. 3rd PARTY SECURITY VENDOR TO PYLON SIGN MAKE FINAL DRY CONTCT (2) CONNECTIONS AT SECURITY GOOSENECK LIGHTS TERMINAL STRIP. GOOSENECK LIGHTS GOOSENECK LIGHTS WALL ART SITE LIGHTS SITE LIGHTS A. LIGHT SENSOR B. PUSH BUTTON (NOT USED) C. SECURITY ALARM SPARE D. MOTION SENSOR SPARE LL1 _uuK N LL4 LL4 LL4 LL ---W C L 4 Cas i ,,. D1 LOCATION OF WALL 32 MOUNTED TIME CLOCK @ 54" D1 AFF. ALL INTERIOR LIGHTING 32 CIRCUITS TO BE ROUTED VIA TIME SWITCH CONTROLLED 32 i CONTACTOR ... _. ... .. DRIVE-THRU MENU BOARD—/ ELECTRICAL LIGHTING PLAN E1 1/4"=1'-0" 7i m =17111i� MOTION DETECTORS 2 MINIMUM ItZiZKe7TIAI ( LIGHTING CONTROL BOARD) C %� ' LL3 LL3I L VIA SW 4 s S LL4 (3) -3 (4) B-4 VIA SW "Sc" VIA TIME CLOCK E 9` 6 � I ............. ; ._...?..... l lil SHEET NOTES: ALL "EX" EMERGENCY & EXIT LIGHTING FIXTURES SHALL BE CONNECTED AHEAD OF ROOM/AREA SWITCHES PER NATIONAL ELECTRICAL CODE (NEC) ARTICLE 700-12(f). VERIFY THE EXACT LOCATION OF SIGNS, AND FASCIA BOXES BEFORE INSTALLATION OF JUNCTION BOXES. HOMERUNS MAY BE COMBINED AS ALLOWED BY THE NATIONAL ELECT. CODE ALL CONDUIT SHALL BE SIZED PER THE 2002 NEC. ❑ELECTRICAL CONTRACTOR SHALL VERIFY EXACT SIGN(S) WIRING 4 REQUIREMENTS WITH THE SIGN SUPPLIER PRIOR TO SUBMITTING A BID FOR THE ELECTRICAL. ELECTRICAL CONTRACTOR SHALL VERIFY THE LOCATION OF ❑S THE PYLON SIGN ON THE SITE PLAN. PROVIDE 2P/30A NEMA 3R, FUSED DISCONNECT SWITCH W/ LIQUID -TIGHT FLEXIBLE CONNECTION TO PYLON SIGN. FUSE H: SIZE PER SIGN MFR'S RECOMMENDATION. 281 E 8 � THE BUILDING SIGNAGE, PYLON SIGN, FASCIA LIGHTING, BUILDING SIGN LIGHTING, DRIVE-THRU MENUBOARD(S), AND SITE .I -; LIGHTING SHALL BE WIRED THRU THE LIGHTING CONTACTORS Y8 FOR AUTOMATIC & MANUAL CONTROL. LL1 I LL1 4 ❑ PROVIDE RACEWAYS, WIRING, AND LAMPS (F40T8) FOR ALL LIGHT - - FIXTURES FURNISHED W/ THE FREEZER/COOLER/STORAGE UNIT. C LIGHT FIXTURES SHALL BE INSTALLED BY ELECTRICAL SIGN: : CONTRACTOR. COORDINATE THE INSTALLATION OF SWITCHES AND I LL4 LL4 TIME LL2 PR GRAD L1 I -® �.. __ __w - 1 4 e LL4 LL4 i ..:_ .__LL4 LL1 j I LL1 ( I L1 � � I 14 32 �._ E__._ O ....E 32 H SPR 32 32 J-BOX FOR SPEAKER AT 10'-4" -- A.F.F., CENTERLINE POPEYES RADIO SYSTEM DESCRIPTION MAKE MODEL QUANTITY RECESSED SPEAKERS" (DINING) 60SE MODEL#18, BLACK 4 RECESSED SPEAKERS' (KITCHEN) MUZAK MRS 8-ST3, BLACK 2 OUTDOOR BOX SPEAKERS^ OW1 701 4 AMPLIFIER PASO MU 3130 BGM 1 SPEAKER SUPPORT OUAM SSB-2 2 SPEAKER BACKCAN QUAM ERD-8 2 CABLE, CONNECTORS, HARDWARE AND SHELF VARIOUS VARIOUS 1 AREA VOLUME CONTROL OUAM OC-10 3 RECEIVER ECOHO STAR 3000 1 DISH CHANNEL MASTER 1,0 ANTENNA 1 " NUMBER OF SPEAKERS MAY VARY DUE TO DESIGN CONSIDERATIONS ' LABOR INCLUDES INSTALLATION OF 150' OF 12 GAUGE SPEAKER WIRE. SEETHE NATIONAL ACCOUNT VENDOR LIST FOR EQUIPMENT SUPPLIER. J +174 PLATES WITH THE EQUIP. SUPPLIER. i C' F J-BOX ON HOOD FOR PRE -WIRED HOOD LIGHTS. Lu G.C. TO VERIFY EXACT ELECTRICAL REQUIREMENTS FOR ILLUMINATED S-) 4 �' 0 SITE/MONUMENT SIGN STRUCTURE W/ SIGN SUPPLIER PRIOR TO p ' L ! ,I E B-21 VIA INSTALLATION. G.C. TO PROVIDE FINAL ELECRICAL HOOK-UP. O TIMECLOCK PROGRAMMABLE NOT USED. W B-17 ,LOCK... S G TIMER °' W (ABLE J 12 ROUTE CIRCUIT VIA EXTERIOR/SIGN LIGHTING CONTACTOR m TIMER (SEE CONTROL SCHEMATIC DIAGRAM SHEET E1. O a J I LL1 H30 3 FIXTURE TYPE "81" EQUIPPED WITH EMERGENCY LIGHTING BATTERY ~O - - WP PACK, THE BATTERY PACK SHALL BE WIRED AHEAD OF ANY SWITCHES. Z EM 0 .I PYLON SIGN - LLI CEILi ( 30 REFER TO SITE 4 36"xS"x8" SHEET METAL GUTTER FOR BALLAST AND CAPACITORS FOR Q 1 4 ---MOUNT PLAN FOR SEE FIXTURES "H". MOUNT GUTTER ABOVE CEILING TO INTERIOR STUDS. >_NOTES 5 & 7 W Ld ' U H30 W 2 TO SITE LIGHTING - LL2� ((, E ( J TYPICAL. SEE SITE Z C ! 30 WP PLAN TO VERIFY LOCATION AND W J +174' �Ij QUANTITY. SEE NOTE 7 p SIGN w VERIFY i � 'EIGHTS WITH RCH. PLANS A-32 A-34 Q VIA TIMECLOCK H PROGRAMMABLE Z TIMER W ZD U O p W co W LIGHT FIXTURE SCHEDULE O MARK DESCRIPTION MANUFACTURER LIGHT FIXTURE COLOR BULBS I — co A 2 x 4 ZR24 LED TROFFER SECURITY LCAT 24-40MLG-EDU-C388-GK (NORMAL) WHITE LED INCLUDED = LCAT 24-40MLG-EDU-ELLI4-GK (NL) U CE B 2 x 2 ZR22 LED TROFFER CREE ZR22-32L-35K-10V WHITE LED INCLUDED CL COOLER/FREEZER BY COOLER MANUFACTURER —� Lu d BALCONY RECESSED SOFFIT LIGHT O D (BY SIGN SUPPLIER/BALCONY) SECURITY 851-DL-100MH-FP-WH-120 WHITE (1) MH100/U/MED 0- SHUTTER UPLIGHT / CUSTOM COLOR � D1 CAST ROUND BOX COVER FOR FIXTURE SECURITY MIC100MHEV/RL6009 ---- EVERGREEN.. (1) MH100/U/MED - � � E MANSARD WALL MOUNT UNIT TERON PNK1260-12ON-JC CLEAR (1) 26W 0 J Q EM EMERGENCY LIGHTING UNIT EXITRONIX LL90 WHITE (2) 5W p Z ER REMOTE EMERGENCY LIGHTING UNIT EXITRONIX LL50H-N4 WHITE (2) 5W F-- c EX LED EXIT EMERGENCY COMBO EXITRONIX VEXUBPWHEL-90R WHITE INCLUDED I. � EXT LED EXITSIGN EXITRONIX LEDRBB WHITE INCLUDED O U LL4 6" RECESSED DOWNLIGHT JUNO IC22LEDG3-3K-1 / 24W-WH WHITE 14W LED H LL3 PENDENT SECURITY FLAVORIETY (2) BLUE CO(3) AMBER (7) 15W (GU-24) j -- cr_ H GOOSENECKS 10OWMH - OUTDOOR HILITE H811/C/GU/602-100MH EVERGREEN (1) MH100/U/MED W WP WALL PACK w/ PHOTO CELL (REAR DOOR) SECURITY SWP-100MH-DB-MT BRONZE (1) MH100/U/MED } J — cn LL2 PENDENT SECURITY PF346315721216 (3) 15W co W LL1 PENDENT SECURITY EDJ31111 RED (1) 15W OL x W > N V N m O N W M Q] O) V M M M LU W co N E > M M Q �- \J Z a oM o m Um L N W W LLJ Q w U o J (p c J U M Z N O p J N Z o w o 0 L w U� g N m m _ d N 0 J w v M N = Z U oo m N m E Y Z a Nc'nali z W p J Q m J U) a W _J Q L.IJ = U W = CV rn o � H L Q z Q L w J = ? O U I W Q = Q U I popeYes J a ^ ` VJ U) W —J Q m M <wcyo w !n w r0 o o O0 E N 8 qS�;'��� No 4 43 ,t�S' •� O g 1 � P FLORIDA P�E464,' C 6" RECESSED WALLWASHER JUNO PL642EU-261 B-WH WHITE 26W TRIPLE TUBE U J RELEASE If — SITE LIGHTING (FIXTURE COUNTS TO BE VERIFIED WITH ARCHITECT AND OWNER) LP 1000 WATT MH FLOODLIGHT SECURITY ASBFOOOMH-DM-MT BRONZE MH1000/U/BT56 - I LP 5" x 7 GAUGE x 25' SQUARE STEEL POLE SECURITY SSSP25-5-7-DBZ BRONZE N/A IOTE: • VERIFY WIND LOAD TO ENSURE POLE SIZE IS SUFFICIENT. • LABOR WARRANTY FOR TWO YEARS IS PROVIDED ON ALL PARKING LOT LIGHTING THRU SECURITY LIGHTING NATIONAL ACCOUNTS. PLEASE CONTACT SECURITY LIGHTING FOR INFORMATION ON LIGHTING PACKAGE, TEL. (800) 544-4848 DAT • NO SUBSTITUTION ALLOWED FOR SPECIFIED LIGHT FIXTURES. PROJECT NO. 2018-002 _ ALL LIGHT FIXTURES LISTED IN THE ABOVE SCHEDULE SHALL BE FURNISHED BY OWNER AND INSTALLED BY THE ELECTRICAL CONTRACTOR, EXCEPT AS NOTED IN PARAGRAPH, PART 1.1.0 OF ELECTRICAL SPECIFICATIONS. NOMENCLATURE DEFINITIONS ISSUE DATE Al2 PATTER #12 ACRYLIC PRISMATIC LENS c EW G OI RC�1'D GGYY CE 12/21 /18 114 GEB 4 LAMP ELECTRONIC BALLAST > 20% THD ELECTRONIC CW20 COLD WEATHER BALLAST COMp4 CODEC ,,. .,. _ ,.,. ,. ,,:,,.::.•,,. PE FACTORY INSTALLED PHOTOCELL ST` LUCIE M DRAWN CHECKED METAL HALIDE SOURCE 3ocC ik JC JC FIXTURE NOTES: 1. SEE ARCHITECTURAL DETAILS FOR MOUNTING LOCATIONS. 3 2. ALL OUTLETS FOR LIGHTS SHALL BE SUPPORTED INDEPENDENTLY OF CEILING 2 LIGHTING CONTROL WIRIING DIAGRAM E1 J N.T.S. 3 LIGHTING CONTROL E1 N.T.S. SYSTEM USING 1/4"ALL THREAD ROD, 3. PROVIDE REMOTE MOUNTED (ON ROOF) PE CELL FOR ALL EXTERIOR FIXTURE, TYPE'WP' NOT ON THE LIGHTING CONTACTOR. 4. BALLAST LOCATION FOR GOOSE NECKS INSTALLED PER N.E.C. m SERVICE PUSH FOR IRRI METER FOR HEAT IN THE C-19 WP J-BOX & DISC SW 4 WIRE TO GREASE CONTAINER FOR HEAT TRACING IN THE FREEZER. RUN 2 - 2" CONDUITS FROM t TELEPHONE EQUIPMENT BOARD TO A LOCATION COORDINATED WITH LOCAL TELEPHONE COMPANY, OWNER REQUIREMENT SERVICE CONDUITS SHALL BE SIZED FOR 25 PAIR (MINIMUM). TELEPHONE SERVICE CABLE, CONDUITS SHALL BE INSTALLED WITH PULLWIRE. CONDUITS RISE FROM U.G. INSIDE EXTERIOR WALL AND TURN -OUT WITH 90 DEG ELLS INSIDE BLDG. AT TERM. BD. SEE ARCHITECTURAL ELEVATIONS. OWNER REQUIRED SEPERATE TELEPHONE SERVICE LINES TO BUILDING: (1) LINE FOR VOICE (1) LINE FOR SECURITY (1) LINE FOR CREDIT CARD (1) LINE FOR CASH REGISTER (1) LINE FOR COMPUTER LINES CABLE/S Q TEL DUAL/DOUBLE TEL 4 L dZ V �d SINGLE TELEPHONE SERVICE CONDUIT TO SPACE BY LANDLORD 3/4" CONDUIT TO TTB FROM EACH TELEPHONE OUTLET V DINING POS_ DRIVE THRU " OFFICE NEMA 5-30R NOTES: 1. G.C. IS RESPONSIBLE TO PULL THE CORRECT WIRE TO BRING THE PHONE LINE FROM THE DEMARK. 2. INSTALL THE APPROPRIATE JACK TO SUPPORT THE PHONE AND DSL ROUTER. ,,,CONDUIT BUSHING WITH TERMINATION AT 6" ABOVE FINISHED CEILING. CEILING GRID 1" OR 3/4" CONDUIT WITH PULL STRING AS NOTED. YRECESSED SINGLE GANG ELECTRICAL BOX. FINISHED FLOOR 2�)TYP COMM. STUB UP DETAIL E2 J NTS REFR TO SITE PLAN FOR EXACT LOCATION EXTERIOR MENUBOARD SEE SITE PLAN FOR ORIENTATION TOTE: )NTRACTOR TO PROVIDE MIN. 70 A 4' LONG CORD ID PLUG FOR ELEC. FRYERS (1 PER EACH). :CEPTACLE SHALL BE POWERTITE 100AMP )JA1034-20D AT 18' R F.F. 1® BRANCH CIRCUIT(S) CONTINUED TO ADDITIONAL OUTLETS, HOMERUN SHOWN FOR CLARITY ONLY. POWER PLAN KEYNOTES 17 CONNECTIONOUTLET AND CAMERA TOBELOCATED NBULKHEAD, 6" ALL KITCHEN AREA RECEPTACLES 1RIFY EXACT BELOW LOCATIONS NDTYP VENNECTIION 7 DP-31i40 42 DP 37 39 41 DP-14 16,18, DP 8,10,12 DP 2,4,6 ❑ REFER TO FOOD SERVICE DRAWING K1 FOR LOCATIONS AND TYPE CONNECTIONS FOR C-27 TAG LOCATIONS NOT SHOWN THIS SHEET. INDOOR AND OUTDOOR CAMERAS WITH G.C.. A-35,37 (TIE) ARE TO BE LOCATED IN ALL CONDUIT ROF ❑ REFER TO HVAC DRG. M1 FOR EXACT LOCATIONS 18 TORUE(WITH- N) ROOF CUURBS FOR THE TIONS gg 2 FOR MECHANICAL HVAC EQUIPMENT. EQUIPMENT REFR TO MECH. PLANS FOR 23 23 D 23 23 23 WALLS/BULKHEADS. NO KITCHEN �� CURB DETAILS. (TYPICAL) AREA RECEPTACLES SHALL BE NEMA 3R FUSED F.ISC. ON WALK-IN CO11. EQUIPMENT 19 PROVIDE I"CONDUIT TO6"ABOVE UNTLOCATEDONR003P30A FUSEPER CEILING. LOCATED IN THE CEILING NAMEPLATE. LIQUID TIGHT FLEX CONNECTION. - -- - MAKE FINAL POWER CONNECTION TO WALK-IN 20 SYSTEM. HOOD NSUL FIRE SUPPRESION COOLER EVAPORATOR, PROVIDE MOTOR SWITCH IN CAST BOX. 21 MAKE FINAL CONNECTION TO MAKE FINAL POWER CONNECTION TO WALK-IN EQUIPMENT 1....._... . ...... . .. .......... ........... _......_ ..._....., _ FREEZER FREEZER EVAP., DEFROSTER, HEAT ^__ TAPE & DOOR HEATER. QQ OFFICE EXHAUST FAN SHALL BE INTERCONNECTED TO OPERATE WITH AREA LIGHTING. INTERLOCK EXHAUST PROVIDE LOCAL 3P60A NEMA 3R NON -FUSED FAN WITH LIGHTS. DISC SW. ON A/C RTU'S LOCATED ON ROOF 23 CONTRACTOR TO PROVIDE MIN. 70 A 4' LONG CORD EQUIP. NAMEPLATE. PROVIDE LIQUID TIGHT AND PLUG FOR ELEC. FRYERS (1 PER EACH). I FLEX CONN. TO UNIT. RECEPTACLE SHALL BE POWERTITE 100AMP EF-4 C-9 F7-1 PROVIDE GFCI PROTECTED 5-20R DUPLEX ADJA1034-200 AT 18" A.F.F. RECEPT. INSTALLED IN WP BOX W/ WP 40" --" C OVER AT RTU TYP 24 RAIN SENSOR H.D.S•' H D J A-20 C( ) C 8 PROVIDE 120V WIRING TO DUCT MOUNTED INTERLOCICW/ ( + 40 i 181 SMOKE DETECTORS AND REMOTE 25 LABEL ALL SWITCHES AND TIMERS ON OFFICE WALL B 11 13,15 LIGHT CIRCUIT f '>? TEST/INDICATORS. FOR EXACT LOCATIONS CEILING MOUNTED B-23 B-5 OF DUCT DETECTORS, REMOTE INDICATORS - - 26 PROVIDE SWITCH IN OFFICE TO OVERRIDE HOOD �W 11��EFOR TV j:; & TEST SWS. (SEE HVAC PLANS). CONTROLS. INTERLOCK WITH HOOD CONTROL PANEL. U 24' 54" 18 -- - . _ DP-32,34,36 I' 9 E.C. SHALL INSTALL AND WIRE RELAY CONTROL 6. A54 _ PANEL PACKAGE FOR HOOD EXHAUST FANS EF-1 27 COORDINATE KNEE WALL RECEPTACLE LOCATIONS O J AND EF-2. PROVIDE POWER AND INTERLOCK WITH GC TO ENSURE ACCESSIBLE AFTER FINAL 0_ 16 B-1 CONTROL WIRING FOR HP1-F CONTROL PANEL INSTALLATION OF UNDER -COUNTER SHELVING W A 19 - -- A-15 14 15 ❑ B 16 I AND HOOD FIRE SUPPRESSION SYSTEM. SEE Of B 19 16 WPLGFI HOOD FAN CONTROL INTERLOCK WIRING DIAGRAM. W A-18 I — WP_ I. SHEET M2. MOUNT STARTERS AND CONTROLS ON O C-3a JIGE WALL. P.O.S. NOTES: I— .) w "� f f sD J j "ON/OFF" SELECTOR. SWITCH AND PILOT LIGHT ~ 81 o.3P 24 D ? U r \ — — j O,tt� 1 O IN NEMA 4X STAINLESS STEEL ENCLOSURE 1. ALL P.O°S. (POINT OF SALE) CIRCUITS SHALL HAVE Z D92 Dsa P2o G a ti ¢ 7 8� 18 { 11i 3 MOUNTED ON THE FACE OF THE HOOD. AN ISOLATED GROUND WIRE BACK TO THE PANEL. W ''£ II PROVIDED BY HOOD MFR. ALL P.O.S. EQUIP. SHALL BE WIRED w o92 dao B 3 g 38 w LLI� ¢~¢ \\: RTU 3 INDEPENDENTLY OF ANY NON-P.O.S. EQUIPMENT. Q D93 It ¢ g u 1 1 PROVIDE 2P30A NEMA 3R FUSED DISC W 100" D24' z SWITCH & L.T. FLEX CONNECTION TO ROOF 2. ALL RECEPTACLES FOR P.O.S. EQUIPMENT SHALL 2 ' EF-21 C-1,3 -�---®a; IG P20 24 0 \ i MTD ICE MAKER COND UNIT, FUSE SIZE PER BE ISOLATED GROUND WITH SURGE SUPPRESSOR QUAD IG w a aL, - -)t .I B-26 MFG'S NAMEPLATE DATA. TYPE. ALL RECEPTACLES FOR P.O.S. EQUIPMENT LLI M `. / C-5.7—'—Q-ji RECPT. 24' z O (f. ., f f '�.� PROVIDE WALL OUTLET W/ISOLATED SHALL BE SINGLE UNIT, UNLESS A DUPLEX Z : 1 Q RECEPTACLE CAN BE USED TO SUPPLY TWO P.O.S. i P30 y -� C :i GROUND RECEPTACLES SUPPORTED FROM W T q,g~� B-3 IG P4" P30 L., -�___ f _ = _ _ _ J I i; UNITS. DUPLEX RECEPTACLES MAY BE USED IN 2 I" c0 ��-,�100 2q" i " " BLDG. LOCATE 6" BELOW CEILING. 44�—"QJ .. .._ M30 ("�-jk I(STRUCTURE FOR VIDEO MONITOR/PRINTER THEIMANAGER'SOFFICE FOR NON-P.O.S.III - EQU PMENT (COMPUTER, MUSIC, FIRE ALARM, CDB10-22,74,26 {� B_3q_ / B-1 16 't & OR HEADSET. VERIFY EXACTO 1i " £ SECURITY, ETC.) (A1 I i 33 REQUIREMENTS & LOCATION. PROVIDE W0 C 1GFI DP-26,28,3 J-BOX AND CONDUIT WITH PULL STRING FOR J -- 3 ALL CIRCUITS FOR P.O.S. EQUIPMENT SHALL BE 'Of a'' ,� RTU-2 ❑ I ( VENDOR DATA CABLES CONNECTED TO THE SAME PHASE OF POWER IN A-18 B 36 I`PROVIDE 3/4" x 18" H x 24" W PLYWOOD TELEPHONE THE PANEL. ALL BRANCH CIRCUIT BREAKERS=C 2 J 18 WP,. ❑6 "' '- : - --- 13 BOARD PAINTED WITH 2 COATS OF "LISTED" FIRE SUPPLYING P.O.S. EQUIPMENT SHALL HAVE j N V N m l`m m cp U m M M m E > M M o c E m o E v d u U r o J m � J W d' N rn 2�� O W U y ^ W WVim_ % N` H S Z N N 'E a Ninau10. ,9,11 FOR HE ; :�,, - , I B-29 IG A-6 1 6 .. LOCKING HANDLES DEVICES. Z GREP„SERECOVERY UNIT. '`" "`A'- 0£ 18 .=-e-.=` ' - J £ RETARDANT LIGHT GRAY COLOR PAINT. AT 96" A.F.F. I (VERIFY=.€XACT LOCATION) — — 46 �_"`_ - PROVIDE QUAD RECEPTACLE ADJACENT TO BOARD. A-29,31 A-13q-11. to to o 0 0 N N m m m m m W o ED 54" mm m °o �40" T A OR IG IG m °o 1811 NOTE: REFER TO OFFICE ELEVATION ON SHEETS Al & A16 SPEAKER BOX NOTE: REFER TO MFR. LITERATURE LITERATURE FOR SPECIFIC INSTALLATION INSTRUCTIONS FOR PREFAB LOOP 4'4' I I I � I f _ 2'-0„ f 2'-6„ MIN. — LOOP/AUDIO f PRE-FAB DETECTOR LOOP SUPPLIED & INSTALLED BY G.C. TO BLDG L-------------- FOR AUDIO CURB OMIT WIRE REINFORCING MESH IN CONC. DRIVE WITHIN 24" OF PREFAB LOOP 3 DRIVE-THRU LOOP DETECTOR E2 NTS IG 1 E2 K72 B 41 PROVIDE # 6 CU, GROUND TO SERVICE ENTRANCE 4. EACH RECEPTACLE TYPE (LOCKING OR STRAIGHTGROUND, SEE DETAIL . C 25 J4„ PROVIDE CONDUITS DOWN IN WALLRTO J-BOXESONS. BLADE) SHALL MATCH THAT OF THE EQUIPMENT W FURNISHED WITHOUT A PLUG THE RECEPTACLE 24 18 14 RECEPTACLE TYPES TYPE. THE P.O.S. EQUIPMENT 0 18" FURNISHED. WHERE P.O.S. EQUIPMENT IS OORDINATE= SHALL BE LOCKING D48 B 27 AT 18' AFF AND ROUTE ALL ELECTRICAL („) " P20 48 f C 15 CIRCUITS WITHIN PRODUCTION COUNTER TO O IG SERVE EQUIPMENT. ` SUPPLIER.LIJ p 21 31 za' GENERAL NOTES: ... In 8.24 B-22 I[ - tv'exat"44xa• PRODUCTION COUNTER ELECTRICAL POWER W 1-9 B-19 '[ --• 8-33 f I 1` CIRCUITS: REFER TO PANEL SCHEDULE "C" FOR A. VERIFY MOUNTING HEIGHTS OF ALL m 0 0 o c e _ 19 ,{ I I£' - 15 CIRCUIT NOS. REFER TO EQUIPMENT SUPPLIER RECEPTACLES WITH EQUIPMENT SUPPLIED PRIOR 32" IG 12 1. A-22 16 . n,; �,_..... .. ..._ .._ _.. SHOP DRAWINGS FOR EXACT LOCATIONS AND TO INSTALLATION. TYPE OF CONNECTIONS FOR EQUIPMENT AND U) 01G J 0 J 4 24 ___.. HEAT LIGHTS IN/OR ON PRODUCTION B. ALL EQUIPMENT ELECTRICAL OUTLETS ARE 32' P30 K72 COUNTER. DIMENSIONED TO CENTERLINE OF BOX FROM O Z 'y'O,— _ _. .. ::. .._. J .._-------- .:.a• ABOVE FINISHED FLOOR. P20 B-14 11fyP 102" E W I TO CENTERLINE OF OUTLET C. ELECTRICAL CONTRACTOR TO PROVIDE CORD & , PLUG CONNECTIONS FOR EQUIPMENT AS d I 17 BOX 102' DENOTES MOUNTING REQUIRED. O HEIGHT ABOVE FINISHED FORDRIVETHRU - - - O J 1 j GRADENVAXTERIOR OF BLDG.) T _ AUDIO SYSTEM SEE / D. ALL DINING ROOM CEILING RECEPTACLES SHALL (TYPICAL EXTERIOR OF BLDG) Q / BE'WHITE _.._ �/� ` DETAIL4THISSHEETa_ _._ _._.. _... _.. __...._...:.. . .,_, W VJ (n -.'� J I �[ t '' £ ( t 9 ` f f w Q Lu Ijllill24 heol (�(((.� III.. O g 1 LL III t 1'hl'jl a ... ui W f Qj ` ^ W P J WP F I-.d. I , I] ,; `: 1 m � [, ..� L L.L N u$i w VERIFY LOCATION ON SITE PLAf� Lu MENU BOARD AND N1 �. t-.:.._..__. _-..__ _._ �.-( - _.,.. _. __ _,.,.. I ¢ N r = I I c ;_ Y SPEAKER POST t ) , 3:g.w, v Z a O rn I � .. ` qq'w � ... ELECTRICAL POWER PLAN & DETAILS � 9 =_ i �•--a .- - 2 2 1 11 : �IX�ilf)+i 1Y'a�i`{ d� SEAL r 1/4"=V-0' _ 5 2 ( O �1 .. Z II i�COORDINATE WITH SHEET K2. CEILING GRID I I f I 1 CONDUIT II I SIGNAL4'x4' J-BOX I "PROVIDE STAINLESS _ STEEL COVER PLATE WIRELESS DRIVE-THRU T- (� W/ 3/4" BUSHING CENTER MODULE f HOLE FOR SIGNAL (WALL MOUNTED) f _ OUTLET BOX" II I I fII �J I 120 VOLT DUPLEX. CIRCUIT B-22 I I II 4"x4" J-BOX LOOP DETECTOR I I COUNTER TOP g 3/4' CONDUIT TO MENU BOARD AND SPEAKER POST. FIN FLOOR VERIFY LOCATION ..,......._..._..m ......___ ON_SITE.PON.._. IIII LL- 4 DRIVE-THRU AUDIO / TIMERS E2 NTS 1 J " W ' 41 Luu w NOTE 1 REFER TO ARCHITECTURAL ELEVATIONS FOR --' EXACTION DIMENSIONED LOCATIONS FOR ALL WALL ,, �.. "'" --Lit Lu OUTLETS - O_ uj (( f I Ij... Q ui V 0— APT wgfA. 2018 \.\G E N No 448A3 #44643 li 19 + i M RELEASE DATE COORIINATE WITH �END )F FRYER 10 2 3 1' 2" �, LL f If �I I � m 27 f 4 , [- m.q 9 I 0 d� 01 2-0" 3-4112" 2'-6" ' 2-4314" 3'-3" 1 11 [1-4[ 1 11 10" ELECTRICAL RECEPTACLE LOCATION 7112" T 6 E2 1/4"=1'-0" I i 1 I III v sn a 6'-2" 5 8 PROJECT NO. REVIEWED FO 2018-002 CODE COMPLI •°,,., ST. LUCIE CO NI SUE DATE BOCC 12/21/18 DRAWN CHECKED JC JC SHEET NO. FILE CrIjor lEZ PANEL MANUFACTURER, I -LINE MAIN BREAKER (AMPS); 800 MAIN LUGS (AMPS)' K.A.I.0- 22 MOUNTE[l RECESSED NAME: PANEL "DP" 3 PHASE 4 WIRE PROJECTNAME: POPEYES 120/208 VOLTS PROJECT NUMBER: 2018-002 FED FROM: TRANSFORMER N 0 E S E Q T A G CKT NO. IDENTIFICATION WIRE/COND C 0 D E LOAD/PHASE (AMPS) CIRCUITBREAKER LOAD/PHASE (AMPS) C 0 D E WIRE/COND IDENTIFICATION CKT NO. E Q T A G N 0 E S A B C TRIP P P TRIP A B C BID 1 COW. OVEN 3#10, 1#10G, 1"C K 24.0 30 3 3 70 56.0 K 3#4, 1#8G, 1"C ELEC. FRYER 2 Al l.0 5 3 24.0 56.0 4 5 24.0 56.0 6 B10 7 COW OVEN 3#10, 1#10G, VC K 24.0 30 3 3 70 56.0 K 3#4, 1#19G, VC B-EC. FRYER 8 Al I.0 5 9 24.0 56.0 10 11 r 24.0 1 1 56.0 12 5 Al l.0 13 ELM. FRYER 3#4, 1#8G, 1"C K 56.0 70 3 3 70 56.0 K 3#4, 1#8G, VC ELEC. FRYER 14 Al l.0 5 15 56.0 56.0 16 17 56.0 56.0 1g 19 PANEL 4#4/0,1#4G,2-1/2"C O 143.0 225 3 3 60 49.0 C 3#6,1#1OG,1"C RTUI 20 21 135.8 49.0 22 23 140.8 49.0 24 25 PANB B 4#4/0, 1#4G, 2-1/2'C 01 11140.4 225 3 3 60 49.0 C 3#6, 1#iOG, VC RTll2 26 27 126.4 1 49.0 28 29 131.9 49.0 30 31 PANE.0 4#4/0, 1#4G, 2-1/2"C O 130.7 225 3 3 60 49.0 C 3#6, 1#10G, 1"C RTll3 32 _iT 135.4 49.0 34 35 113.9 49.0 36 5 Al l.0 37 BLED. FRYER 3#4, 1#8G, 1"C K 58.0 70 3 3 70 56.0 K 3#4, 1#8G, 1"C ELEC. FRYER 38 Al l.0 5 39 56.0 56.0 40 41 ss.o 5s.o 42 1 574.1 1 557.E 1 546.6 1 371.0 1 371.0 1 371.0 PHASEW AMPS: 945.10 945.10 :LARGEST CONNECTED PH. "AMPS" R{ASE'B' AMPS: 928.57 340.08 :LARGEST CONNECTED PH. "KVA" R-IASE'C' AMPS: 917.63 664.33 :LARGEST DEMAND PH. "AMPS" 239.06 :LARGEST DEMAND PH. "KVA" LIGHTING (L) RECEPTACLES (R) KITCHEN EQUIPENT (K) LARGEST MOTOR (M) A/C COOLING (C) OTHER (0) COW. LOAD (AMPS) DEMAND FACTOR DEAR (AMPS 97.4 1.25 121.75 204.7 NEC 144.00 756.6 NEC 491.81 81.5 1.25 101.88 147.0 1.00 147.00 149.0 1.00 149.00 2. LOCK ON BREAKER 3. VIA TIME CLOCK 4. ISO GROUND. 5. PROVIDE BUILT PANEL MANUFACTURER: NQOD MAIN BREAKER (AMPS): MAIN LUGS (AMPS): 225 K.A.I.C.: 22 MOUNTED: RECESSED CAPABILITY NAME: PANEL "A" 3 PHASE 4 WIRE PROJECT NAME: POPEYES 1201208 VOLTS PROJECT NUMBER: 2018-002 FED FROM: PANEL DP 0 T E S E Q T A G CKT NO. IDENTIFICATION WIRE/COND C 0 D E LOAD/PHASE (AMPS) CIRCUIT BREAKER LOAD/PHASE (AMPS) C 0 D E WIRE/COND IDENTIFICATION CKT N0. E Q T A G NO T E S __A_T B C TRIP P P TRIP A B C 1 FRYER HOOD EF-1 2#12, 1#12G, 3/4" C M 11.0 20 1 1 20 5.0 M 2#12, 1#12G, 3/4" C EF-3 2 3 FRYER HOOD EF-2 2#12, 1#12G, 3/4" C M 11.0 20 1 1 20 2.5 0 2#12, 1#12G, 3/4" C HOOD CONTROLS 4 2 K42 5 CARBONATOR 2#12, 1#12G, 3/4" C K 14.4 20 1 1 20 10.5 R 2#12, 1#12G, 3/4" C KITCHEN CONY RECEPT 6 A31 7 MARINATOR 2#12, 1#12G, 3/4" C K &0 20 1 1 20 0.8 R 2#12, 1#12G, 3/4" C OFFICE CAB. FAN 8 2 2 C10.27 9 SANDWICH 2#12, 1#12G, 314" C K 6.5 20 1 1 20 0,8 0 2#12, 1#12G, 3/4" C SERVICE DOORBELL 10 C20 11 TOASTER 2#12, 1#12G, 314" C K 12.5 20 1 1 20 5.0 0 2#12, 1#12G, 3/4" C IRRIG CONTROLS 12 2 C30 13 PRODUCT HOLD 2#12, 1#12G, 3/4" C K 4.5 20 1 1 20 5.0 O 2#12, 1#12G, 3/4" C ANUSL SYSTEM 14 2 2 A54 15 FREEZER 2#12, 1#12G, 3/4" C K 12.0 20 1 1 20 5.0 K 2#12, 1#12G, 3/4" C REFRIGERATOR 16 860 2 2 E10 1 17 IFREEEZER EVAP 2#12, 1#12G, 3/4" C K 13.3 20 1 1 20 4.5 R 2#12, 1#12G, 314" C RECEPT DINNING 18 2 A48.2 19 REFRIG. BATTER 2#12, 1#12G, 3/4" C K 2.3 20 1 1 20 9.0 R 2#12, 1#12G, 314" C RECEPT DINNING 20 71 SPARE - 20 1 1 " 20 -5.0 O 2#12, 1#12G, 3/4" C SECURITY CAMERA 22 2 DOD 23 HOLD CABINET 2#12, 1#12G, 3/4" C K 17:5 20 1 1 20 4.5 L 2#12. 1#12G, 3/4" C COOLER/FREEZR LIGHTS 24 2 D61 25 CHUB WARMER 2#6, 1#10G, 3/4" C K 47.6 80 2 2 30 16.6 K 2#10, 1#10G, 3/4" C MICROWAVE 26 D20 27 476 166 28 D30 29 31 PRODUCT AYSEM 2#12, 1#12G, 3/4" C K 5.2 20 1 1 20 8.3 K 2#12, 1#12G, 3/4" C HEAT TRACE FRZ 30 E10 2 5.2 20 1 1 20 9.3 L 2#4, 1#6G, VC SITE LIGHTING 32 3 33 SPARE 1 20 7.0 L 2#0, 1#6G, 1"C SITE LIGHTING 34 3 F15.1 35 37 HEATED HOLDING UNIT 2#10, 1#10G, 1" C K 18.8 25 2 1 20 4.5 M 2#12, 1#12G, 3/4" C COOLER EVAP 36 E10 2 18.8 3 20 5.2 K 3#12, 1#12G, 3/4" C WALK IN COOLER COMP 38 5 D20 39 41 MICROWAVE 2#10, 1#10, 3/4"C K 16.6 30 2. 5.2 40 168 52 42 94A 1 93.7 1 98.3 1 50,9 j 42.1 1 42.5 1 PHASE 'A' AMPS: 145.30 145.30 :LARGEST CONNECTED PH. "AMPS" PHASE V AMPS: 135.80 52.28 :LARGEST CONNECTED PH. "KVA" PHASE'C'AMPS:140.83 84.41 :LARGEST DEMAND PH. "AMPS" 30.37 :LARGEST DEMAND PH. "KVA" CONN. LOAD DEMAND DEMAND - (AMPS) FACTOR LOAD (AMPS LIGHTING (L) 20.8 1.25 26.00 RECEPTACLES (R) 24.8 NEC 24.80 KITCHEN EQUIPENT (K) 211.3 NEC 137.36 LARGEST MOTOR (M) 31.5 1.25 39.38 A/C COOLING (C) 0.0 1.00 1 0.00 OTHER (0) 18.3 1 1.00 1 18.30 1. EQUIPMENT GROUNDING 2. LOCK ON BREAKER 3. V CLOCK 4. ISO GROUND 5. HACR TYPE PANEL MANUFACTURER NQOD MAIN BREAKER (AMPS): MAIN LUGS (AMPS): 225 K.A.I.C.: 22 MOUNTED: RECESSED NAME: PANEL"B" 3 PHASE 4 WIRE PROJECT NAME: POPEYES 120/208 VOLTS PROJECT NUMBER: 2018-002 FED FROM: PANEL DP N 0 T E S E Q T A G CKT NO. IDENTIFICATION WIRE/COND C 0 D E LOAD/PHASE (AMPS) CIRCUIT BREAKER LOAD/PHASE (AMPS) C 0 D E WIRE/COND IDENTIFICATION CKT NO, E Q T A G N 0 T E S A B I C TRIP PIPPIPI TRIP __A__T B C 2 1 RTU RECPT & DUCTS 2#12, 1#12G, 3/4" C R 3.0 20 1 1 20 5.4 L 2#12, 1#12G, 3/4" C DINING LIGHTS 2 3 2 3 DIGITAL MENUBOARD 2#12, 1#12G, 314" C R 8.3 20 1 1 20 4.3 L 2#12, 1#12G, 3/4" C PENDANT LIGHTS 4 3 3 5 COUNTER/ RESRTOOM LIGHT 2#12, 1#123, 314" C L 3.0 20 1 1 20 5.0 R 202, 1#12G, 3/4" C TELEPHONE BOARD 6 2 3 7 KITCHEN LIGHTS 2#12, 1#12G, 3/4" C L 6.0 20 1 1 20 3.0 R 2#12, 1#12G, 3/4" C RECEPT OFFICE 8 2 2 A48.1 9 REFRIG. BATTER 2#12, 1#12G, 3/4" C K 2.3 20 1 1 20 4.5 R 2#12, 1#12G, 3/4" C MUSIC SOUND 10 2 N31 11 WATER HEATER 3#4, 1#8G, VC M 50.0 70 3 1 20 4.5 R 2#12, 1#12G, 3/4" C COMP/ PRINTER 12 2 13 50.0 1 20 15.0 R 2#12, 1#12G, 3/4" C D/T WINDOW 14 15 50.0 1 20 15.0 R 2#12, 1#12G, 3/4" C SHOW WINDOW 16 3 17 FRONT SIGN 2#1Z 1#12G 3/4" C L 10.0 20 1 1 20 4,5 K 2#12, 1#12G, 314" C D/T MENUBOARD 18 3 2 19 VIDEO MONITOR 2#12, 1#12G, 314" C R 9:0 20 1 1 20 0.8 L 2#12, 1#12G, 3/4" C THE CLOCK 20 2 3 21 PYLON SIGN 2#6, 1#10G, 1" C L 10.0 20 1 1 20 5.0 R 2#12, 1#12G, 3/4" C D/T AUDIO 22 23 SHOW WINDOW 2#12, 1#12G, 3/4" C R 15.0 20 1 1 20 5.0 R 2#12, 1#12G, 3/4" C POS SYSTEM/ PRINTER 24 4 2 25 SECURITY SYSTEM 2#12, 1#12G, 3/4" C R 3.0 20 1 1 20 15.0 R 2#12, 1#12G, 3/4" C SHOW WINDOW 26 4 27 POS SYSTEM 2#12, 1#12G, 3/4" C R 4,5 20 1 1 20 8.5 L 2#12, 1#12G, 3/4" C EXT. LIGHTS 28 3 29 UNDER COUNTER SAFE 2#12, 1#123, 3Wl C R 3.0 20 1 1 20 - 6.5 L 2#12, 1#12G, 3/4" C EXT LIGHTS 30 3 2 31 COMPUTER/ PRINTER 2#12, 1#12G, 314" C R %0 20 1 1 20 9.8 L 2#12, 1#12G, 3/4" C EXT LIGHTS 32 3 K32 33 SODA DISPENSERS 2#12, 1#12G, 3/4" C K 4.0 20 1 1 20 6.5 L 2#12, 1#12G, 3/4" C WALL ART LIGTS 34 3 5 35 WALK IN FREEZE COMP 3#12, 1#12G, 3/4" C K 5.4 20 3 1 20 5.0 L 2#12, 1#12G, 3/4" C DIGITAL PRE SELL 36 2 37 5.4 1 20 8.0 R 2#12, 1#12G, 3/4" C POS SYSTEM 38 4 39 5.4 SPACE 40 41 SHOW WINDOW 2#12, 1#12G, 314" C R 15.0 20 1 SPACE 42 84.6 1 101.4 57.0 1 41.8 1 30.5 PHASE'q'AMPS', 143.40 143.40 :LARGEST CONNECTED PH."AMPS" PHASE V AMPS: 128.37 51.60 :LARGEST CONNECTED PH. "KVA" PHASE'V AMPS: 131.90 163.31 :LARGEST DEMAND PH. "AMPS" 68.77 :LARGEST DEMAND PH. "KVA" CONN, LOAD DEMAND DEMAND LOAD (AMPS) FACTOR (AMPS LIGHTING (L) 73.8 1.25 92.25 RECEPTACLES (R) 150.9 NEC 145.50 KITCHEN EQUIPENT(K) 16.2 NEC 10.53 LARGEST MOTOR (M) 50.0 1 1.25 1 62.50 A/C COOLING (C) 0.0 1.00 0.00 OTHER(0)l 0.0 1.00 0.00 1. EQUIPMENT GROUNDING 2. LOCK ON BREAKER 3. V PANEL MANUFACTURER: NQOD MAIN BREAKER (AMPS): MAIN LUGS (AMPS): 225 K.A.I.C.: 22 MOUNTED: RECESSED 5. HACR TYPE CIRCUIT BREAKER NAME: PANEL "C" 3 PHASE 4 WIRE PROJECT NAME: POPEYES 120/208 VOLTS PROJECT NUMBER:2018-002 FED FROM: PANEL DP N 0 T E S E Q T A C0 CKT NO. IDENTIFICATION WIRE/COND C 0 D E LOAD/PHASE (AMPS) CIRCUIT BREAKER LOAD/PHASE (AMPS) C 0 D E WIRE/COND IDENTIFICATION CKT N0. E Q T A G N 0 T E S A B C TRIP PIP I TRIP A B C D92 1 HOLDING CABINET 2#12, 1#12G, 3/4" C K 13.9 20 1 20 5.1 L 2#12, 1#12G, 3/4" C HEAT LAMP 2 H10.4DP 3 13.9 2 30 23.7 K 2#10. 1#10, 3/4"C HOLDING CABINET 4 D94 D92 5 HOLDING CABINET 2#12, 1#12G, 3/4" C K 13 9 20 21 23.7 6 7 13.9 1 20 16.0 R 2#12, 1#12G, 3PV C HAND DRYER 8 9 HAND DRYER 2#12, 1#12G, 3/4" C R 16.0 20 1 1 20 &0 R 2#12, 1#12G, 3/4" C POS TERMINAL 10 4 D70 11 HOT WATER DISP 2#10, 1#10, 3/4"C K 18.8 30 2 3 20 10.7 M 3#12, 1#12G, V C ICE COMPRESSOR 12 K10 13 16.6 10.7 14 K31 F 15 SODA DISPENSERS 2#12, 1#12G, 3/4" C K 5.0 20 1 10.7 16 17 SPARE 20 1 1 20 6,4. K 2#12, 1#12G, 3/4" C UC REFRIG. 18 J40 19 GREASE COL. SYSTEM 2#12, 1#12G, 3/4" C K 10,0 20 1 1 20 4.5 K 2#12, 1#12G, 3/4" C BISCUITHOLD 20 B65 D70 21 HOT WATER DISP 2#10, 1#10, 3/4"C K 18,6 30 2 3 35 26.0 K 3#10, 1#10G, VC HOLDING BIN 22 D93 23 16.6 26.0 24 26 K71 25 TEA BREWER 2#12, 1#12G, 3/4, C K 14.0 20 1 26.0 3 A92 27 HEAT TRACE BOSS 2#12, 1#12G, 3/4" C 0 10.0 20 1 1 20 8.5 K 2#12, 1#12G, 3/4" C FRYER CONTROLS 28 5 29 LIFT STATION 3#10, 1#10, 1"C 0 8.0 20 3 1 3 20 SHUNT TRIP 30 31 8.0 8,0 0 3#10, 1#tOG, VC LIFT STATION 32 34 33 SO 8.0 35 SPACE 80 36 37 SPACE SPACE 38 39 ISPACE SPACE 40 41 ISPACE SPACE 42 PHASE'A' AMPS: 146.70 PHASE'B' AMPS: 151.40 PHASE'C'AMPS: 129.90 LIGHTING (L) RECEPTACLES(R) KITCHEN EQUIPENT (K) LARGEST MOTOR (M) A/C COOLING (C) OTHER(0) 1 (0,4 1 M.0 1 00.1 1 CONN. LOAD (AMPS) DEMAND FACTOR DEMAND LOAD (AMPS 5.1 1.25 6.38 32.0 NEC 32.00 145.1 NEC 94.32 8.0 1.25 10.00 0.0 1.00 0.00 0.0 1.00 0.00 NOTES: 1. EQUIPMENT GROUNDING 2. LOCK ON BREAKER 3, VIA TIME CLOCK 4, ISO GROUND 5. SHUNT TRIP BREAKER 4 - #4/0, THWN, CL # 4 CU GND IN 2 1/2" CONDUIT - - TIME CLOCK INTERIOR PANEL LIGHTING CIRCUITS TO -Do LC1 BE ROUTED VIA TIME SWITCH CONTROLLED CONTACTOR PANEL PANEL PANEL ,A„ „B„ DPI 800A M.C.B I -LINE 4 - #410, THWN, CU # 4 CU GND IN ? 1/2" CONDUIT ELECTRICAL POWER RISER DIAGRAM E3 / 1/4„=1 _0„ 70.3 1 81.9 1 74.8 151.40 :LARGEST CONNECTED PH. "AMPS" 54.48 :LARGEST CONNECTED PH. "KVA" 103.89 :LARGEST DEMAND PH."AMPS" 37.38 :LARGEST DEMAND PH. "KVA" ENGRAVED SIGN - "MAIN DISCONNECT\ IDENTIFICATION PLAQU i LISTED FOR AVAILABLE MAIN VIP FAULT CURRENT 3P800A &S/N I CT PROVIDE & INSTALL REVIEWED F( BREAKERECT CABINET AND NEMA 3R I METER IN ACCORD WITH CODE COMPLII POWER CO REQUIREMENT T. LUCIE COL \ 3 SETS OF 4- #350 KCMIL, THWN, CU, EACH IN 1 p �+ 1 #.E. . A EQUIP. BOND —�-� 3 1/2" CONDUITS VIA CT CABINET TO TO PAD BOCC PER N.E.C. ARTICLE 250.66 — — — MOUNTED TRANSFORMER, GC'/ ELECT. AND TABLE 250.66 CONTRACTOR SHALL COORDINATE SERVICE SINGLE POINT PER LOCAL UTILITY CODE. (3) SETS OF 4 - #350— GROUND L pi FAULT CURRENT KCMIL, THWN, CU #1/0 CU FROM XFMR GND EACH IN 3 1/2" RUN #2/0 CON CTOR TO 5/8 " No CONDUITS. 3/4"10-1 #2/0 CU BOND TO DIA. x 10'-0" LENGTH GROUNDING MINIMUM OF ONE OR COLD WATER PIPE PER ROD. GROUNDING TO CONFORM TO MORE GROUNDING STEEL REBARS IN N.E.C. ARTICLE 250,52 (A) SECTION 250-50 (N.E.C.) METHODS SHALL BE USED FOUNDATION (1) AND 250.53 (D) WITH #2/0 CU 0 W U O D_ W W m O H O Z W 0_ Q W _ H LLI U Z W _ Z CD En LU w Z Q H Z LU O 0 W LU H O H co E_ S 0 P- LU W d O D_ W _ H O J J Q Z Q H _ _0 a O U co CO Lu W LU W J LU W d LU W > N a N m M � w M � � JL mp W c E Z o c a U U�Lu a Lu = Z Z 'Q W J J M J N w V > W m o� N N O Z cn O aJN# 9 z a o c W w O w ^N LU z v ti L. N O N m c'Efs U U z w o Q m U) 0- LLJ J U rn LuI ~ H 2i Q z Q Lu = O LU g H O cl) popeYes z ui NG O Q �� ^�•, VJ UJ z w CD d- w U :5 Q— CN w a D O Y Y C N� {!1n V Q N® L1_ mo�w^/� // � v_J L.J_ z ``Q VJ UJ —I W U U) W z I� J U LU J U H W Lu J w y LU No . * 44643 �pF O R I O P.•`��$�. RELEASE ' 11 DATE PROJECT NO. 2018-002 ,i u ,.:,n etn.inni ISSUE DATE 1 12/21/18 I DRAWN CHECKED JC JC " _FItz PIP3 ry 0 TE DSL I Q. V1 �POS � - SERVICE ' POS / BB BB —1.- ------ — ------------------------ / / ABOVE I CEILING 11 OFFICE i I `) T4 .� I 1 I I BB \ I 1 1 V ` � 111 RIVE THRU ic \ v WS 3 <> BEI 1 E4 1/4"=1'-U„ SALES REGISTER CONNECTIONS 1. CABLES SHALL BE COAX. 2. BUMP BARS SHALL BE MOUNTED TO DELIVERY SYSTEM AT AREAS MARKED "BB". 3. BUMP BAR CABLES SHALL BE RUN THROUGH DELIVERY SYSTEM FROM MOUNT UP THROUGH WALLS TO ABOVE THE CEILING AND BACK TO THE MANAGER STATION. 4. CRT MONITORS SHALL BE MOUNTED ON CEILING BRACKETS PROVIDED BY REGISTER SYSTEM. 5. WHERE CABLING IS INSTALLED IN WALLS, IT SHALL BE ROUTED IN A 1" CONDUIT THROUGH WALL TO ABOVE ACCESSIBLE CEILING. I �: 3 I LEGEND ---- BUMP BAR WIRING VIDEO MONITOR AND POS WIRING SECURITY WIRING ® BB - BUMP BARS V1 = VIDEO 1 V2 = VIDEO 2 V3 = VIDEO 3 M POS- POINT OF SALE TERMINAL 01 CRT NOTES: 1. MONITOR BRACKETS TO BE SUPPLIED AND INSTALLED BY P.O.S. VENDOR. 2. G.C. TO SUPPLY 2x4 BLOCKING AND TO SECURE BLOCKING AT LOCATION PER P.O.S. VENDOR DIRECTION. VERIFY W/ P.O.S. VENDOR BEFORE INSTALLATION (2) U-f EL. 9'-4 A.F.F. BRACKET CC BY P.O.S. VEI MONITOR ASSEMBLY S.S. STEEL MONITOR BRACKET DBL. 2X4 BLOCKING W/ SIMPSON "U" HANGERS @ EA. END TO TO ROOF TRUSSES OR JOISTS TOG.C. INNER STEEL CHANNEL CEILING TILE FLASHING PLATE OUTER STEEL CHANNEL ATTACH MONITOR BRACKET W/ (2) 1/4" BOLTS WHT. PLASTIC SLEEVE TO CONCEAL CHANNELS & POWER CORDS (NOT SHOWN) 2 MONITOR BRACKET E4 1 1/2"=V-0" REVIEWED CODE COMPI ST. LUCIE Ct BOCC uJ W U 0 O a Lu w m O I- I- O Z W } Q} L J- Ld U Z W _ z 0 U W 0 w _ 1-- 0 Z Q N H Z Lu U O 0 w N w H O H _ U` F- Lu W a O tY a Lu Lu _ O J J Q Z Q I- _ 0 d O U H U Lu Lu Lu sn Lu J U U W a Lu U J W�// LI- (Pi U a_ Lu Lu I— ui = Z W Q ui o � IU m N J U z Z z Lu W O K 'OOO N N N W W co M N d N Q O U 6 Q o L 0 N !n LL LL is u� Z ui o J 00 Lu CL Lu J Q Lu Q U W ~ m C H W Z z :3� U p p w = ~ o U) w g O U) pOPe eS Lu O J_ Q U) W J rn z W d W U .a a- u CV i w � N a i - SEAL Q0 �G E NSF ` No 643 Z ir p. TAT F :Qtij ,o"O�P R1'a�,`. FL AVE!R,643 RELEASE IJAI 2 3 a 5 I s PROJECT NO 2018-002 r ISSUE DATE I 12/21/18 CHECKED N_ EC.ppY 'f NOTESI 1. THE FOOTCANDLE LEVELS AS SHOWN ARE BASED ON THE FOLLOWING CRITERIA. ANY SUBSTITUTIONS IN SPECIFIED FIXTURES OR CHANGES TO LAYOUT WILL AFFECT LIGHTING LEVELS SHOWN AND WILL NOT BE THE RESPONSIBILITY OF SECURITY LIGHTING. 2. DISTANCE BETWEEN READINGS 10, ** - SPECIFY COLOR LABEL FIXTURE TYPE: A VPL-96NB-280-5k-T4-UNV-RA-** SYMBOL 6uaNrin I CONFIG I QUANTITY I FITTERS I QUANTITY EPA HEIGHT LLF '0 7 SGL 3 TTFVIPER 3 1.00 20' 0.9 DBL180 2 TTFVIPER 2 2.00 POLE TYPE: SES-18-40-1-TA-** (4") 11 i 2.5 +3.0 +3 . C + + + + + + + + + + '0 '0 '0 + + '0 + 0.3 0.4 0.5 0.8 1.1 1.6 2.1 2.5 2.4 0.9 0.8 0.8 0.7 0.5 0.4+' 0.3 0.3 0.3 0.3 +0 . 9 1. 4 +2 . 3 3. 5 +4 . 7 4. 5 [� r° 0.5 +1.2 2. 0 3. 0 4. 4 +l . 5 6. 5 9, A i 0.8 1,5" 2.2 3 1 4 6 6.8 5.2 �.3 0.5 1 2 1.2 1. 1 . 4 1.4 1.5 1.9 2.3 2.9 3.6 +5.2 6.4.5 4 4 2.1 2.1 2. p/ 1 +2.3 -+ + + + + u + 2. 2 2 .2 2. 5 2 9 3. 1 ti7 . 3. 8 4 .,.� _.W 3 83w. 7 3. + . T , 3.4 3.7 3.6 3.9 3.9 3,"6 4.,1 3.8 j E 6.2 6.2 6. li + 4 . 7 0 f r W U 16.4 +5 .7 +6. 5 6 1 + . 6 E +2.8 +3 . 1 .2 3.8 5 0 z I a � [f t7 . 8 -. 4 . 67 . Lu 9 tl . 0 +4 . 6 j +1. $ +2 . 3 i +1 +8 .2 +5 . m 1 40 . 1-- Z I ~O 5. 5 12 , 0 15.6 5. 4 +". 0 +1 : 1 .9 5. 4w Q _.., @180 J .2 cf) of r +3 a + + + z LLI 1. 1.8( 14 4 8.6 4. ~ <c� 4, 6 2 j 9 PROP POPEYES € 4. 5 z Qcn co 2@ 1 0 2,246 SF FOOTPRINT I W w = l _: ____ _ __ _ x +5 . 6 6 +5. 9 . 1 3' 9 FF 10.00 (NAND) +1 . +2 . l 3 , 5 +5. 9 t7 . z p = w 9 + 2 Q 5.3 w z p o . ,....,. , _..... ._ .. ._. W P 7 5.3 *1 . 8 +6. 6 8 +1 . 5 +2 . 3 +6. +6. 8 t7 w C - 5 .. o +4.3 N t� z > N 9 N m M m W M CJ M W 0 Ll- N g > M z_ Li o =hi c) 10� N F- W = z Q w U o J m N J U m J LU 1- M rn 5 z 1-Z LL .L U N aI # r. _ b3 O J Q N w d LL 4 2 I I 1 6 r +2 : [ (a 4 9 ... +4 4 1 +2 y 3 } 3, . .2 .7 . +3 5 w p �I . N I +4 7 _ +4 4.7 *5. 1 4 . 9 ii 4 Q, f +1 . 2 .2 �� +3 2 3 3 U o 1.;9 I 3 AN) .. � € . .2 . 2.9 N 1 2 $._.. -'+2.9 � 3. 6 3. 9 ,.,__. ..._,......._ ._.._....._.._... + 8 ._.... I . +2 . �2 2.3 ((.... _,._._._... ....__._._ I +3.0 ..__.. 3.0 3 . Lu 2 o 0 p o 0 0 1 4 \ t 3.0 j 2.0,t2.3 1 3.3 4.0 4.0 3.7 ._.,.,_ . 3.2 2.9 2.5 3. w,.._ 3.6 3.6 3. W 1.0 3.7 ( 1.5 2.0 3.1 4.3 +5.8 5.7 5.6 5.7 4.2 3.4 2.9 bu 3.4 4 j.;' 5.5 + 5. W o O 0.7 .,, _.. 5. 0 w (n (q ILA l.1 + +`' 3.2 5.2 + + + 8.3 5.8 5.6 + 8.4 +5.8 + 3.7 + 3.0 + + 3.6 5.2 + 8.2 +5.9 + 5.4 '8 8. O w � + 0.4', +5.7 J a P LL 0 Q L)0- w � 04 w a + + 4.6 + + + 5.3 6.2 6.7 + + 5.3 4.9 + 3.2 + 2,3 + '4 2.8 4.7 + + 5.3 6.0 + 6.9 + 5. x a Y J o w 0.3 4.4 No 4 43 ir OL' 9 t ATE :!L� �4�.c 0 9 E O R 1 Q P 4%`� ��*;.S'0NALlr'- % ROBE' WIlle�ASE FLORIDA PE. #44643 ............. _._m..,.._ .�....... .�... ..... ......... ..... EASE ........._..._ . RELEASE 1 2 7 LIGHTING`"' CI7x3 712 (MIDWAY IROAD) "'N� t 3 i G00 " Atlh NM RottingOmde IL GM RE . - UNLESS OTHERWISE SPECIFIED. ALL DINERSI IN scALE NOT TO SCALE QUANTITY WIND LOAD ALLOWED * EPA PROJECT WIND LOAD CRITERIA BASED ON: 120mph 2,4 ASCE 7-10 WIND SPEEDS (3-SEC PEAK GUST MPH) 50 YEAR MEAN RECURRENCE INTERVAL 1. THIS UGH71NG DESIGN IS BASED ON INFORMATION SUPPLIED BY OTHERS TO SECURITY LIGHTING SYSTEMS. SITE DETAILS PROVIDED HEREON ARE REPRODUCED ONLY AS A VISUALIZATION AID. FIELD DEVIATIONS MAY SIGNIFICANTLY AFFECT PREDICTED PERFORMANCE. PRIOR TO INSTALLATION" CRITICAL SITE INFORMATION DRAWN BY NW Si. LI5 POINT -BY -POINT FOOTCANDLE PLOT (POLE LOCATIONS, ORIENTATION, MOUNTING HEIGHT, ETC.) SHOULD BE COORDINATED MATH THE CONTRACTOR AND/OR SPECIFIER RESPONSIBLE FOR THE POPEYES PROJECT. 4946 S 25TH ST 2. LUMINAIRE DATA IS TESTED TO INDUSTRY STANDARDS UNDER LABORATORY ST LUCIE COUNTY, FL CONDITIONS OPERATING VOLTAGE AND NORMAL MANUFACTURING TOLERANCES OF STORE MUUER LAMP, BALLAST, AND LUMINAIRE MAY AFFECT FIELD RESULTS 3. CONFORMANCE TO FACILITY CODE AND OTHER LOCAL REQUIREMENTS IS THE RESPONSIBILITY OF THE OWNER AND/OR THE OWNER'S REPRESENTATIVE. 4. THIS LAYOUT MAY NOT MEET TITLE 24 OR LOCAL ENERGY REQUIREMENTS. IF THIS LAYOUT NEEDS TO E COMPLIANT MATH TITLE 24 OR OTHER ENERGY DATE DRAWING NUMBER REQUIREMENTS, PLEASE CONSULT FACTORY MATH SPECIFIC DETAILS REGARDING PROJECT REQUIREMENTS SO THAT REVISIONS MAY BE MADE TO TIME DRAWING. 12/ 13/ 1 H 413 4 6 PROJECT NO. 2018-002 I ISR SUE kDATE lo%r. 12/21/18 DRAWN CHECKED GM JC SL1 C-29.31.33 3 #1m0, 1 #10G, VIC V , C-32:34:36 3 #10, 1 #10G, 1 "C u,r rwp )wP SPEAKER POST f MENU BOARD (PROVIDE DISCONNECT) --- r B-18 _QL 2#12, 1 #12G, 3/4"C (4.5 AMPS, 120v / 1 PHASE) 2@180 B-21 2 #6, 1 #10G, 1 "C (185',VD=2.0%), i0 I \ Wpu) , �I. S x l 1 w ,x. PROP POPEYES 2,246 SF FOOTPRI FF 10.00 (NAVD) L1 A' A-32 2 #4, 1 #10G, 1"C (300',VD=2.0%) sO CIX3 712 (IY1[IDWAY'R®AD) A 2 #6, 1 #10G, 1 "C (230',VD=2.0%) 2@180 0 W 0 0 O a W W m 0 0 z W Q } w L C) z w x Z (D U) W 0 W x E- 0 z Q Cn H z W 0 O 0 W m W 0 I" x UJ W O a Lu W x F-- O J a 0 z Q H 2 U ti M M M W C6 N LI_ > M M g2�v J Z M E y W W F-- Lli = Z U0 Q W U r o J m N J U w w M m z cn v Z zOo w L r O > N N WO :J F- Lu 11J Z V NO y.M... y f0 M N Q N a S � � w ciJaii U z W 0 Q m W w J Q W a C=> LLI ~ rn o r- z Q L ui J / O C m N x 0 Cn pop Ye eA �W G_ O 4yy ii VJ `^ F Q U) w J rn z LU c6 w co U 0 Q_ w CN w Oa Y a SEAL O Lu A > No 44643 ' Lu v) = *.•• :* W • ,9. �.. , �. OF 40 L� •, STATE ����S�' R _vC3_5 REVIEWED CODE COMP ST. LUCIE C RELEASE a'Itt x F W N � DATE t z 3 4 5 6 � .. SHEET NO. LEC2 SHEET NO. LEC2