Loading...
HomeMy WebLinkAboutBUILDING PLAN PAGE 16-301 BUILDING SECTION Scale: l/4"=1'-0" II SPECIFICATIONS: DIVISION 7: THERMAL AND MOISTURE PROTECTION SECTION 7B: MEMBRANE ROOFING SECTION 7A: BUILDING INSULATION GENERAL PROVISIONS GENERAL PROVISIONS 1. SCOPE: FURNISH AND INSTALL MEMBRANE ROOFING SYSTEM THROUGH THE NATIONAL ACCOUNT 1. SCOPE: FURNISH AND INSTALL FIBERGLASS INSULATION PROGRAM DESCRIBED BELOW, INCLUDING ALL AND ROOF INSULATION TO PROVIDE A COMPLETELY FLASHING, BACK FLASHING INSULATION AND RELATED INSULATED THERMAL SHELL WITH NO BREAKS OR MATERIALS REQUIRED FOR A COMPLETE, PENETRATIONS. WATERPROOF INSTALLATION. 2. NOTES: INSULATION VALUES SHALL COMPLY WITH STATE 2. NOTES: AND LOCAL CODE REQUIREMENTS AND/OR VALUES SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN, WHICHEVER A. PAYMENT FOR THIS SECTION WILL BE MADE REQUIREMENT PROVIDES THE GREATER "R" VALUE. AFTER RECEIPT OF MANUFACTURER'S FULL REPLACEMENT NDL (NO DOLLAR LIMIT) 10-YEAR 3. QUALITY CONTROL: THE OWNER SHALL BE NOTIFIED WHEN WARRANTY FOR MATERIALS AND LABOR. THE INSULATION IS IN PLACE, PRIOR TO THE INSTALLATION OF FINISH MATERIALS. B. CAUTION: THE HVAC SYSTEM IS DESIGNED WITH THE THERMAL CHARACTERISTICS OF TPO MEMBRANE MATERIALS AND NO VARIATIONS ARE ALLOWED UNLESS GIVEN PRIOR WRITTEN APPROVAL BY 1. FIBERGLASS INSULATION CONCEALED IN WALLS BY POPEYES ARCHITECTURE AND ENGINEERING OWENS-CORNING OR JOHNS-MANVILLE. 51/2", R-19, DEPARTMENT. FIBERGLASS ROLL INSULATION WITH KRAFT TYPE VAPOR BARRIER ON INSIDE FACE. 3. NATIONAL ACCOUNTS: - - - 2. FIBER GLASS INSULATION EXPOSED ABOVE CEILING BY (1) A NATIONAL ACCOUNT HAS BEEN ESTABLISHED OWENS-CORNING OR JOHNS-MANVILLE. 5 1/2", R-19 WITH JPS ELASTOMERICS CORPORATION FOR FIBERGLASS ROLL INSULATION WITH INTEGRAL FOIL PURCHASING TPO ROOFING SYSTEM REINFORCED KRAFT FACING ON INSIDE FACE WITH FLAME MATERIALS. REFER TO TITLE SHEET FOR HAZARD RATING OF 25/50 OR LESS. INFORMATION. 3, ROOF INSULATION BOARD: CLOSED CELL (2) INSTALLATION OF ROOF MEMBRANE SYSTEM POLYISOCYANURATE FOAM CORE WITH ONLY BY MANUFACTURER APPROVED FACTORY -LAMINATED FOIL FACES. FOAM CORES WITH INSTALLERS. USING NON -APPROVED INSTALLERS FLAME SPREAD OF 25 OR LESS AND COMPRESSIVE MAY VOID WARRANTY PROGRAM WITH STRENGTH OF 20 PSI OR GREATER (ASTM D-1621) WITH A MANUFACTURER. a MINIMUM AGED R VALUE OF 16 BY ONE (1) OF THE FOLLOWING APPROVED MANUFACTURERS: (3) NOTIFY ROOFING CONTRACTOR A MINIMUM OF THREE (3) WEEKS IN ADVANCE OF NEEDED A. AC FOAM SUPREME BY ATLAS INDUSTRIES ROOF INSTALLATION DATE. B. THERMA ROOF PLUS BY R-MAX C. TEM-PRO SP BY THE TEMPLE EASTEX (4) MATERIALS AND INSTALLATION FOR ROOFING AND FLASHING SHALL ONLY BE THROUGH THE THE LISTED INSULATIONS ARE AVAILABLE THROUGH NATIONAL ACCOUNT PROGRAM DESCRIBED. QUALIFIED ROOFING INSTALLERS. SEE NATIONAL ACCOUNTS INDEX. (5) MANUFACTURER'S REPRESENTATIVE SHALL INSPECT THE ROOF INSTALLATION, IF REQUIRED,. 4. PERIMETER FOUNDATION INSULATION (AND 2" MASONRY PRIOR TO ISSUING 10-YEAR NDL MATERIALS AND WALL CAVITY INSULATION WHEN SHOWN) SHALL BE LABOR WARRANTY. STYROFOAM SM BY DOW CHEMICAL CO. OR APPROVED EQUAL, 2" THICK. THERMAL CONDUCTIVITY SHALL BE .20 BTH/HR/SQ.FT./INCH THICKNESS AT 75 DEG F MEAN TEMPERATURE, R-10 VALUE. MATERIALS 5. CONCRETE BLOCK CtiLlUSULATION FOR MASONRY WALLS SINGLE PLY -ROOF (BASE BID) SHALL BE SILICONE= D PERLITE LOOSE -FILL INSULATION BY A ME F THE PERLITE INSTITUTE. 1. MEMBRANE ROOFING SYSTEM: TPO, MECHANICALLY FASTENED45-MIL. PERFORMANCE A. ROOF MEMBRANE: 45-MIL, REINFORCED, TPO, WHITE, 1. INSTALLATION: HYPALON ROOF MEMBRANE. B. MEMBRANE FLASHING: SAME AS ROOF MEMBRANE, EXCEPT A. FIBERGLASS INSULATION: STAPLE AND/OR TAPE IN PLACE E"MOLDI S REQUIRED. WITH VAPOR BARRIER SIDE INWARD. ALL JOINTS SHALL BE C. MOLD ING MOLDED FLASHING NON -REINFORCED, WHITE, TPO LAPPED TO PREVENT MOISTURE VAPOR MIGRATION. ALL MEMBRANE, HYPALON FLASHING MEMBRANE. PENETRATIONS AND PLUMBING AND ELECTRICAL BOXES D. METAL FLASHING AND ROOF SCUPPERS: ELASTOMERIC SHALL BE INSULATED ON THE OUTWARD SIDE. ANY JOINTS COATED METAL AS REQUIRED. NOT OVER WOOD FRAMING OR BLOCKING SHALL BE TAPED E. MEMBRANE FASTENERS: FOR WOOD/STEEL DECK THOROUGHLY. STUFF AROUND DOOR FRAMES AND ELASTOMERICS (OLYMPIC CR-10) FASTENERS WITH EXTRA CLOSELY SPACED FRAMING MEMBERS. FLUOROCARBON CORROSION -RESISTANT COATING. FASTENERS ARE NOT TO PROTRUDE BELOW ROOF DECK B. ROOF INSULATION: USE MECHANICAL FASTENERS WITH GREATER THAN 1 ". STEEL OR WOOD DECK. INSTALL IN ACCORDANCE WITH - F. INSULATION FASTENERS: FOR WOOD/STEEL DECK MANUFACTURER'S INSTRUCTIONS OF SIX (6) PER BOARD STANDARD ELASTOMERIC (OLYMPIC CR-10) FASTENERS MINIMUM. STAGGER PANEL END JOINTS AT ADJACENT WITH CORROSION -RESISTANT COATING. PANEL MID POINT. G. MEMBRANE ADHESIVE - ELASTOMERIC BONDING ADHESIVE -SOLVENT-BASED CONTACT ADHESIVE. C. PERIMETER FOUNDATION INSULATION: INSTALL FROM TOP H. PRIMER: SOLVENT -BASED SYNTHETIC RUBBER PRIMER OF SLAB DOWNWARD 24" WHEN FOUNDATION DEPTH USED TO PREPARE MEMBRANE FOR REPAIR. PERMITS. OTHERWISE INSULATION SHALL EXTEND FROM I. CAULKING: ELASTOMERICRLL-PURPOSE SEALANT OF - TOP TO BOTTOM OF SLAB AND THEN HORIZONTALLY UNDER EXTERIOR GRADE. a, SLAB 24" TOWARD INTERIOR OF BUILDING. J. TRAFFIC PAD: WALKWAY PAD. _ D. MASONRY CAVITY WQQLI,, I SULATION: INSTALL IN CAVITY WHEN SHOWN BET�AN41A ONRY WALL REINFORCING AS 2. ROOF INSULATION BOARD; CLOSED CELL POLYISOCYANURATE FOAM CORE WITH WALL IS BEING LAID. FACTORY -LAMINATED FOIL FACES. FOAM CORE WITH � FLAME SPREAD OF 25 OR LESS AND COMPRESSIVE E. CONCRETE BLOCK C�Ltt-Ityf,SULATION: INSTALL WHEN �y STRENGTH OF 20 PSI OR GREATER (ASTM D-1621) WITH A eNx' SHOWN IN ACCORD' 1`Y�""NTH MANUFACTURER'S MINIMUM R VALUE OF 16, AC FOAM SUPREME BY ATLAS OR RECOMMENDATIONS EQUAL APPROVED BY JPS ELASTOMERICS, INC. PERFORMANCE 1. SURFACE PREPARATION: THE ENTIRE AREA TO BE ROOFED SHALL BE FREE OF DEBRIS AND GROSS IRREGULARITIES, 2. ROOF FLASHING: FLASHINGS SHALL BE INSTALLED IN ACCORDANCE WITH NRCA INSTRUCTIONS. A. FLASHING MEMBRANE SHALL BE FULLY ADHERED, USING BONDING ADHESIVE, TO VERTICAL SUBSTRATES. IN ADDITION, MEMBRANE FLASHINGS SHALL BE MECHANICALLY FASTENED AT 6" O.C. HOT AIR WELDING SHALL BE USED AT THAT PORTION OF THE FLASHING THAT OVERLAPS 6" ONTO THE FIELD OF THE ROOF MEMBRANE OR ONTO AN ADJACENT FLASHING. 3. ROOFING SHEET: MEMBRANE SHALL BE UNROLLED IN AN AREA TO BE COVERED. MECHANICAL FASTENERS AND PLATES SHALL BE INSTALLED ALONG THE LEADING EDGE OF THE MEMBRANE AND AT THE SEAM, THROUGH THE INSULATION AND INTO THE ROOF DECK. SPACING PATTERN AS DETERMINED BY JPS ELASTOMERICS TO RESIST LOCAL WIND LOADS. ADJOINING ROLLS OF THE MEMBRANE SHALL OVERLAP THE FASTENED EDGE OF THE INSTALLED MEMBRANE BY 4 1/2" MINIMUM, SEAM AREA SHALL BE CLEANED AND HOT AIR WELDED WITH AN APPROVED HOT AIR WELDING MACHINE. INSTALL EXTRA LAYER OF MEMBRANE UNDER EQUIPMENT AND EQUIPMENT SUPPORTS NOT ATTACHED THROUGH ROOF MEMBRANE. 4. 4' X V INSULATION BOARDS ARE TO BE FASTENED TO THE DECK WITH A MINIMUM OF SIX (6) FASTENERS PER BOARD. ENSURE FASTENERS DO NOT PENETRATE CONDUIT OR OTHER ITEMS BENEATH THE ROOF DECK. STAGGER PANEL END JOINTS AT ADJACENT PANEL MIDPOINTS. USE MECHANICAL FASTENERS WITH STEEL OR WOOD DECK. 5. TRAFFIC PAD: ADHERED TO ROOF AT TOP OF ROOF LADDER WITH CONTACT ADHESIVE COMPATIBLE WITH ROOF MEMBRANE. 6. CLEANUP: THE ROOFING CONTRACTOR SHALL CLEAN THE CONSTRUCTION AREA OF HIS DEBRIS AND SHALL REMOVE HIS DEBRIS TO A JOB SITE TRASH CONTAINER. 7. WARRANTY: FURNISH TO THE OWNER THE MANUFACTURER'S NDL (NO DOLLAR LIMIT) 10-YEAR WARRANTY FOR FULL REPLACEMENT OF MATERIALS AND LABOR. MODIFIED BITUMEN SHEET ROOFING (OPTION A) PART 1-GENERAL 1.01 SUMMARY A. PROVIDE THE FOLLOWING: 1. WHITE GRANULAR MODIFIED BITUMEN ROOFING SYSTEM AND ROOFING SYSTEM AND ROOF INSULATION. 1.02 SUBMITTALS A. SUBMIT FOR APPROVAL SAMPLES, PRODUCT DATA, WARRANTY, TEST REPORTS, MAINTENANCE DATA. 1.03 QUALITY ASSURANCE A. COMPLY WITH GOVERNING CODES AND REGULATIONS. PROVIDE PRODUCTS OF ACCEPTABLE MANUFACTURERS WHICH HAVE BEEN IN SATISFACTORY USE IN SIMILAR SERVICE FOR THREE YEARS. USE EXPERIENCED INSTALLERS. DELIVER, HANDLE, STORE MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. B. LISTING: UL CLASS [A] [B] [C] EXTERNAL FIRE EXPOSURE, AND CLASS [30] [60] [901 WIND -UPLIFT REQUIREMENTS. C. LISTING: FM CLASS I CONSTRUCTION. 1.04 WARRANTY A. ROOFING WARRANTY: MANUFACTURER'S 10 YEAR WARRANTY. PART 2-PRODUCTS 2.01 MATERIALS A. MANUFACTURERS: FIRESTONE BUILDING PRODUCTS CO., ELOTEX CORP. GAF BUILDING MATERIALS SUP REME ROOFING AND WATERPROOFING OR APPROVED EQUAL. PROVIDE MATERIALS COMPATIBLE WITH ROOFING SPECIFICATIONS FOR SPECIFIC JOB FROM THE FOLLOWING: B. MODIFIED BITUMEN SHEET ROOFING: 1. TYPE: FULLYADHERED. 2. MODIFIER: ATACTIC POLYPROPYLENE (APP). 3. MODIFIER: STYRENE-BUTADIENE-STYRENE (SBS). C. AUXILIARY MATERIALS: 1. VAPOR RETARDER: BITUMINOUS VAPOR RETARDER. 2. INSULATION: GLASS -FIBER BOARD. 3. INSULATION: PERLITE BOARD. 4. INSULATION: POLYISOCYANURATE-FOAM BOARD. 5. INSULATION: COMPOSITE INSULATION BOARD, 6. INSULATION: PHENOLIC -FOAM BOARD. 7. INSULATION: CELLULAR -GLASS BOARD. 8. INSULATION: FIBERBOARD. 9. INSULATION: EXTRUDED POLYSTYRENE BOARD. 10. WALKWAY PROTECTION BOARDS: COMPATIBLE WITH SYSTEM. - _- 11. SHEET METAL ACCESSORIES: SMACNAANDNRCA RECOMMENDATIONS. PART 3 - EXECUTION 3.01 INSTALLATION A. INSPECT SUBSTRATE AND REPORT UNSATISFACTORY CONDITIONS IN WRITING. BEGINNING WORK MEANS ACCEPTANCE OF SUBSTRATE. COORDINATE INSTALLATION WITH OTHER TRADES, INCLUDING CARPENTRY, FLASHING AND PENETRATING WORK. B. COMPLY WITH NRCA ROOFING AND WATERPROOFING MANUAL AND MANUFACTURER'S INSTALLATION INSTRUCTIONS, C. CLEAN, PRIME AND PREPARE SUBSTRATE. D. INSTALL INSULATION WITH TIGHTLY BUTTED JOINTS AND NEATLY FITTED AROUND PENETRATIONS. E. BEGIN ROOF INSTALLATION ONLY IN PRESENCE OF MANUFACTURER'S REPRESENTATIVE. F. INSTALL WALKWAY PROTECTION MEMBRANE AT LOCATIONS INDICATED AND WHERE REQUIRED TO PROVIDE ACCESS TO ROOF MOUNTED EQUIPMENT. G, RESTORE OR REPLACE DAMAGED COMPONENTS. PROTECT WORK FROM DAMAGE. STEPPED YOND N Foa 'EpMP�'�P� GG 000��G`�v S 'DO N � N N J QMl 6Mi W m D D E > a � L U "Ury� '. W [..W ll H- Lu = /= l\\ v ``v�''1 W I J p J m J � W �W U � � N N Z Lu (7 O CD Z Z LL W U y U p -- w rNi in v0} Nai EIr C3 w U 0 O O_ w D' w m O F- O z w D' LU w x uP U z w z 0 W W O W H 0 Z Q W II W U '< , LU U w 11 O[ U f- x 0 z w UJ a Q LU U Of x W _[ H M O Q Z W� N W U p 0 0- CV w z W �- a 30^Y C.D r SEAL O_ O O F F H 1 °v W LU i. •'_ LU (R989' of W A W LU HAROLD DANIEL X FL. REG. w 77 N Z5 RELEASE DATE 2 J 4 5 PROJECT NO. 2018-002 t .aS3PN{SN MIiOIIVNtiII vi � ki v N 3@vi ilU 3!ei r ISSUE DATE 12/21/18 DITACHECKED GM ��� HDH A A7 2 A10 _ T/O CMU 16'-8" A.F.F. 1 LIGHT FIXTURE, SUPPLIED BY OWNER & INSTALLED BY G.C. T/O TIE BEAM VARIES - COORD. 1" EIFS OVER VAPOR BARRIER ON CMU I C) ROOFING MEMBRANE TO TURN UP AN[ OVER PARAPET CANT STRIP PREFAB. WOOD TRUSS ® 24"O.C. TO I DESIGNED PER LOADS ON SHEET S-2 ROOFING MEMBRANE OVER RIGID INSULATION (R-30 ROOF ASSEMBLY) '(2) 2x8 CANT. WD. LEDGER, SEE STRUCTURAL —1/2" PLYW OVER 2X4 FURRING, FILL CAVITY, W/ 1 1/2" RIGID INSULATION' —(1) #5 VERT. REBAR FILLED CELL 032" O.C. MAX CEILING - SEE SHEET A-3 KITCHEN 4 T/O TIE BEAM I 14'-0"A.F.F. I Ir I 11 1" EIFS OVER VAPOR BARRIER ON CMU I' /2„1/ it's I I' 1/2" x 1/2" REVEAL JOINT BY EIFS MANUFACTURER. JOINT TO BE CONTINUOUS AROUND BUILDING. CONT. METAL FLASHING GREASE TANK & CO2 ENCLOSURE BY VENDOR—\ I Co I ROOFING MEMBRANE OVER RIGID INSULATION (R-30 ROOF ASSEMBLY) NOTE: SEE SHEET S-3 FOR TYP. TRUSS FRAMING DETAILS (2) 2x8 CONT. WD. LEDGER, SEE STRUCTURAL 1 (FOR CO2 A10 CHASE DETAIL) �� �i�r4 ��5 �1�s'. k' �wnS�• I I } LWALK-IN-BOXE SHEET FOR ADDITIONAL A13 INFORMATION t FREEZER 7 2 X 2 X 1/8" ANGLE AT TOP AND AT EACH END OF ENCLOSURE II 4 A10 __..._..__ .. ... I I 1- 1/2" EXPANSION JOINT I ` 6 MATERIAL I 4" 3000 PSI N I CONCRETE WALK WITH- 6 X 6 X 10 W.W.F. 77 C s, SEE FOUNDATION PLAN FOR DETAILS LlAB 2 A10 T/O CMU I 18'-0" A.F.F. PREFABRICATED PVC WINDOW SHUTTERS FASTENED TO WALL J-BEAD AND SEALANT AT EIFS PENETRATIONS .�, T/O STEPPED TIE BEAM Y VARIES - COORD. W/STRUCTURAL LIGHT FIXTURE, INSTALLED BY G.C. AT EACH WINDOW SHUTTER TOP RNL TO REMAIN LEVEL ADJUST 4'-0 - BALCONY ® D/T WINDOW RECESSED LIGHT FIXTURE, SEE LIGHTING SCHEDULE SIMULATED STONE VENEER OVER VAPOR BARRIER ON ROOFING MEMBRANE TO TURN UP AND OVER PARAPET CANT STRIP PREFAB. WOOD TRUSS 24"O.C. TO BE DESIGNED PER LOADS ON SHEET S-2 ROOFING MEMBRANE OVER RIGID INSULATION (R-30 ROOF ASSEMBLY) �m i / z NOTE: SEE SHEET S-3 FOR j = 0 N U TYP. TRUSS FRAMING DETAILS 0 Cr a I / > (2) 2x8 CONT. WD. LEDGER, SEE STRUCtLL I �1/2" GWB OVER 1x2 FURRING, FILL { CAVITY W/ I-1/2" RIGID INSULATION I _(1) #5 VERT. REBAR FILLED CELL 032" O.C. MAX CEILING - SEE SHEET A-3 I - I IAl WALL FRAMING SEE SHEET A-1 W-0" A.F.F. LINTEL DRIVE THRU INDOW SEE SHEET A17 7 PSI PROVIDE J-BOX FOR 30 DEDICATED CIRCUIT FOR in POWER FEED TO WINDOW 3 °O 0 I EXTERIOR SHEATHING I C" SLOPE CONCRETE AWAY FROM inBLDG. 0 2 A10 T/O CMU --�' 16'-8" A.F.F. ^ I T/O STEPPED TIE BEAM ROOFING MEMBRANE TO TURN UP AND OVER PARAPET CANT STRIP PREFAB. WOOD TRUSS I 24"O.C. TO BE DESIGNED PER LOADS ON SHEET S-2 ROOFING MEMBRANE OVER RIGID INSULATION (R-30 IF ROOF ASSEMBLY) LIGHT FIXTURE, NOTE: SEE SHEET S-3 FOR SUPPLIED BY TYP. TRUSS FRAMING DETAILS OWNER & INSTALLED BY G.C. I N 1 EIFS OVER VAPOR — BARRIER ON CMU 8 COT. LEDGER, SEE I I 3TRU T RALL LIGHT FIXTURE, E SUPPLIED BY OWNER & INSTALLED BY G,C. STANDING SEAM METAL I I 1/2" GWB OVER 1x2 FURRING, FILL CANOPY INSTALLED BY CAVITY W/ -1/2" RIGID INSULATIO MANUF. I (1) #5 VERT. REBAR FILLED CELL' 032"' O.C. o I s` MAX BOTT. OF AWNING�jw I I 9'-4" A.F.F. CEILING 'LING SEE SHEET A-3 - - - Al - - 1/2" EXPANSION JOINT MATERIAL N STOREFRONT & DOOR SEE SHEET A-17 q I > N O N m m rn rn M M M Lu m �✓ `n E i M M M E �_ / V N I L N d Lu LJJ f0 rLu p, 1 Z VNl CD W Z Q LJJ J J m L J U ,M W Z W !n v M rn W Z 0 l O W U -moo- g? 10 O N ULLj = Z c m m N T Z N N N C m g a¢ n L N fn d LL 0 Lu O 0 O w CL w 01 CoO F_ H O z Luw w x H L z z Lu CD w Oo 0 x Lu o a � z U) Lu z ZD oLu Cn w N O Cn F-- ILLJ x � Z o 0- O OOf J w Q w U) Co Lu J Z /W � uj N Z W z ' r— a x �e Cf = a J 0 a rAL oLu>� DINING U) aHAROL TTER III X FL. REG. 98913 w J RR FARF nATF PROJECT NO. 2018-002 ISSUE DATE 12/21/18 1177 DRAW CHECKED GM HDH r SHEET NO. �1 1 BUILDING SECTION Scale: 3/4"=V-0" 2 BUILDING SECTION Scale: 3/4"=1'-0" TBUILDING SECTION ole: 3/4"=V-0" 4 BUILDING SECTION Scale: 3/4"=V-O" 2 A10 T/O CMU 16'-8" A.F.F. T/O TIE BEAM VARIES - COORD.VV/STRUCTURAL / LIGHT FIXTURE, SUPPLIED BY OWNER & INSTALLED BY G.C. 1" EIFS OVER WATER RESISTANT BARRIER ON r_— CMU_--- LIGHT FIXTURE, SUPPLIED BY OWNER & INSTALLED BY G.C. STANDING SEAM METAL CANOPY INSTALLED BY I MANUF. I o i BOTT. OF AWNING I 9'-4" A.F.F w — ROOFING MEMBRANE TO TURN UP AND OVER PARAPET —CANT STRIP PREFAB. WOOD TRUSS ® 24"O.C. TO BE DESIGNED PER LOADS ON SHEET S-2 F- ROOFING MEMBRANE OVER RIGID INSULATION (R-30 ROOF ASSEMBLY) NOT: SEE SHEET S-3FOR j ? o TYPE TRUSS FRAMING D DETAILS 3 � o a / w \ `(2) 2x8 CO,T. WD. LEDGER, �1/2" GWB OVER 1x2 FURRING, FILL CAVITY W/ -1/2" RIGID INSULATION (1) #5 VIER . REBAR FILLED CELL 032" O.C. MAX CEILING - SEE SHEET A-3 STOREFRONT & DOOR SEE SHEET A-17 DINING I I I I 1 2 A10 _ L I I II �I I 1" EIFS OVER WATER RESISTANT BARRIER ON CMU I I I � I ROOFING MEMBRANE TO TURN UP AND OVER PARAPET -CANT STRIP -PREFAB. WOOD TRUSS ® WO.C. TO BE DESIGNED PER LOADS ON SHEET S-2 -ROOFING MEMBRANE OVER RIGID INSULATION (R-30 ROOF ASSEMBLY) z � z TP�TRUSSFRA FRAMING DETAILS NG ETAI S o I& a (2) 2x8 CONT. WD. LEDGER, SEE STRUCTURAL 1/2" PLYWD OVER 1x2 FURRING, FILL CAVITY W/ 1-1/2" RIGID INSULATION (1) #5 VERT. REBAR FILLED CELL 032" O.C. MAX -2x8 JOIST AT 16" O.C. FOR RESTROOM GYP. BD. CEILING 1/2" GYPSUM BOARD CEILING AT RESTROOMS SIMPSON "U" TYPE HANGER, TYP. 20 FIREBLOCKING IN EACH STUD CAVITY AT LINE OF CEILING RESTROOM 1 A10 T/O CMU I r 1 19'-4" A.F.F. I L I !J L OIL T/O TIE BEAM 164" A.F.F. .r 1" EIFS OVER WATER RESISTANT BARRIER ON TAT CMU ROOFING MEMBRANE TO TURN UP AND OVER PARAPET CANT STRIP PREFAB. WOOD TRUSS 24"O.C. TO BE DESIGNED PER LOADS ON SHEET S-2 ROOFING MEMBRANE OVER RIGID INSULATISON (R-30 ROOF ASEMBLY) NOTE: SEE SEE SHEDS- FOR TYP TRUSS FRAMINGTRUSS FRAMING D�AILS r(2) 2x8 CONTI WD. LEDGER, ' STANDING SEAM METAL SEE STRUCTURAL I CANOPY INSTALLED BY I I MANUF. I I 1/2" GWB VIER 1x2 FURRING, 1-1/2" RIGID ILL AVIT (/ 1 S REBAR 0,i ' DO.C. FILL CELL o I MAX _ _ _ CEILING - SEE SHEET A-3 5 LIGHT FIXTURE, A11 SUPPLIED BY OWNER & INSTALLED BY G.C. STOREFRONT & DOOR SEE SHEET A-17 DINING :` 1 I I!SEE FOUNDATION PLAN FOR SLAB DETAILS �f �,_...I T/O TIE 14'-0" A I�CHI ;11 11. 1 ';� 1 I NOTE: SEE STRUCTURAL PLAN FOR TRUSS TRUSS DETAILS I' x R I I I I I I I- I 3/4" x 2'-0" STL. RODS ® 12" O.C. VERT. SECURED TO 2"0 /4" STL. RAILS (STRINGER) LOCKING MOUNTABLE SECURITY LADDER GUARD 10 1/2" X 4 X 3/8" FLAT WELDED TO 2 1/4" STRINGER AND 4" X 4" X 1/4" X 3"L ANGLE FASTENED THRU WALL WITH GAL. 6" X 3/4" BOLT o I I II '' SEE FOUNDATION PLAN FOR SLAB DETAIL L7- ro BOTTOM CHORD OF PRE-FAB TRUSS ATTACH STUDS TO STRUCTURE I ABOVE ® 48" O.C. 1/2" GYP. BD, OR 1/2" PLYWD. TO 6" ABOVE CEILING MIN. UNLESS NOTED OTHERWISE. CEILING - HEIGHT VARIES - SEE SHEET A-3 _ PROVIDE 2x FIRESTOPPING BLOCKING AT CEILING HEIGHT MR) WALL WIDTH VARIES - SEE SHEET A-1 BLOCKING AT CENTERLINE OF WALL 1/2" PLYWD. AT ALL KITCHEN WALLS, 1/2" GWB AT ALL OTHER WALLS. SEE FINISH SCHEDULE FOR FINISH PER LOCATION. WHERE REQUIRED Y U I O of in P.T. PLATE IN CONTACT W/ SLAB 0 w M 0 a w of w m O O z w G: a w s LLi U z w Z O UJ w 0 w s z w 0 U O 0 w w s H O U) _ D: w a 0 a w w s F- O J 0 z H 2 C7 a O U U) U w w w Cn w U U w a X w cn 79 R ' N U M M M W N IJL top t00 m N > M M Z o c 0 V L U � � a m W W F- W = Z U 0 Q� Z Q W U o J m N J U m W 0' O N N O Z—V, ~ 2 -o M LJL O W tp o N w U F O iQ N N. w 7 0 U -M N M Iw- z CO N ?i N z N r -5 ¢ �cnali U Z W 0 Q m U) w d W J = U rn W t_- ctic w� Q z Qcr z w W m O U N w Y = O U i pop Ye ejs Z W Q_ O Q U) U) w J rn z w n w U � N w w o ti n a 0- J Q0 a J r RELEASE PROJECT NO. 2018-002 ISSUE DATE 12/21/18 DRA CHECKED G `O HDH 1 BUILDING SECTION Scale: 3/4"=1'-0" 2 BUILDING SECTION Scale: 3/4"=V-0" 3 BUILDING SECTION Scale: 3/4"44" 4 BUILDING SECTION Scale: 3/4"44' 5BUILDING SECTION Scale: 3/4"44' 1 SECTION DETAIL -PARAPET Scale: Y=1'-0" EIFS OVER VAPOR i BLACK MASTIC SEALANT CONT. AT ENTIRE PERIMETER OF BUILDING BASE CONT. EFIS DRAINAGE STRIP --- BASE FLASHING----� 1/2" EXP. JOINT MATERIAL ' CANT TOP PLATE AND NAILER FINISHED METAL STAINLESS PARAPET CAP MEMBRANE. TURN UP OVER PARAPET IX, COORDINATE WITH SIGN OR /2" PLYWD. SEE SHEET A-1. 3LOCKING WHERE REQ'D. VALL FINSIH, REFER TO INISH SCHEDULE 1/2" USG "DUROCK" TO 18" A.F.F. LOOSE FILL MASONRY INSULATION ("PERLITE" OR EQUAL) 1-1/2" PT. FURRING AND RIGID INSULATION 5 SECTION DETAIL - BOTTOM OF WALL (EIFS Scale: T=1'-0" 2 SECTION DETAIL - PARAPET Scale: Y=1'-0" EIFS OVER VAPOR — BARRIER ON CMU PAINTED ACCENT BAND 3'-0" A.F.F. A.F.F.-0" A.F.F. TOP OF ACCENT BAND CONT. EIFS STARTER TRACK 2-8 A.F.F. TOP OF STONE VENEER _ CONT. SEALANT TO BACKER ROD CONT. METAL FLASHING SIMULATED STONE VENEER 4 SECTION DETAIL - STONE VENEER Scale: 3"=1'-0" STRIP WEEP PANEL FASTENERS VERSETTA- STONE VENEER (VERSETTA)- VAPOR BARRIER LAP VAPOR BARRIER OVER STARTER STRIP VERSETTA STARTER STRIP WEEP W/ FLASHING BLACK MASTIC SEALANT CONT. AT ENTIRE PERIMETER OF BUILDING BASE 1/2" EXP. JOINT MATERIAL CANT TOP PLATE AND NAILER FINISHED METAL STAINLESS —PARAPET CAP MEMBRANE. TURN UP OVER PARAPET IX, COORDINATE WITH SIGN OR WALL FINISH, REFER TO FINISH SCHEDULE 1/2" PLYWD. SEE SHEET A-1 1-1/2" P.T. FURRING (USE 2x4 IN WATER WALLS IN KITCHEN, COORD. WITH PLAN) AND RIGID INSULATION 1/2" PLYWD. SEE SHEET A-1. BLOCKING WHERE REQ'D. WALL FINSIH, REFER TO FINISH SCHEDULE 1/2" USG "DUROCK" TO 18" A.F.F. LOOSE FILL MASONRY INSULATION ("PERLITE" OR EQUAL) 1-1/2" PT. FURRING (USE 2x4 IN WATER WALLS IN KITCHEN, COORD. WITH PLAN) AND RIGID INSULATION 6 SECTION DETAIL - BOTTOM OF WALL (STONE VENEER) Scale: 3"=1'-0" ALL—PURPOSE SEALANT ROOFING MEMBRANE ROOFING TERMINATION BAR FASTENED 6" O.C. WITH ROOFING SCREW GUTTER STRAP TOP OF TIE BEAM CONT. METAL DRIP EDGE (OPTIONAL) 4" x 6" GUTTER BY G.0 E.I.F.S. OVER VAPOR BARRIER FASTENERS ® 12" O.C. 2x6 P.T. NAILERS AS REQ'D 3 SECTION DETAIL - THRU WALL SCUPPER Scale: 3"=1'-0" EIFS OVER BARRIER ( FASTENER WITH AS RE PVC (SCH 40) E FILL WITH 4a SECTION DETAIL - STONE VENEER Scale: 3"=1'-0" INSTALL BUSHING AFTER EIFS APPLICATION HAS HARDENED. DRILL HOLE SLIGHTLY LARGER THAN BUSHING THROUGH INSULATION ONLY, STOP AT CMU. CAULK OPENING PRIOR TO INSERTING FASTENER TO SEAL PENETRATION. REFER TO SPECIFICATIONS MANUAL FOR EIFS MANUFACTURERS ASSEMBLY DETAILS. I I II I I I I i I i I ( I I EIFS OVER VAPOR 77q—BARRIER ON CMU 2" INTEGRAL MOUNTING 3/8" I.D. x 1-1/4" METAL FLANGE SPACE AT EACH SCREW 1/8" ALUMINUM ENCLOSURE CONT. SEALANT FOR GREASE TANK AND CO2 (BY OTHERS) F®a vkv��E pov�'�PNt sv.F,O cco 7 CONNECTION AT GREASE ENCLOSURE (PLAN DETAIL) Scale: Y=1'-0" > > N V N m m N O W y LL lD (D m N E > M M I..L- / n Z a o c E O W W F- Lij U CD Z Q W U r o t W U m W K O N N rn_ Lu W U K ', w U N a O > N U v Z N o a U C' o N N E d Q Z g N r N � O V �= LL i!1 a N is j C.� Z Lu J m I CA J a W J U Q uiuj w i= o 2 Z w J U Q 0 w\ / ? O � Y 2 ZD O cf) popeves Z w O J //�^ U] J i Lu J rn > 0 M w r Z � W I W w C N L A w C 0 7 ;> 5 U) Q W ii' NM LL ON LV J F W F— w Xw W DEC 7 1 71118 HAROLD DANIEL NUTTER III FL.REG. 98913 RCLCHJC URIC 2 3 4 5 6 !I I4 t{t[ iii:iil�.4 4'... .t i:, l "• ,�e i. �ti PROJECT NO. 2018-002 ISSUE DATE 12/21/18 DRA24 CHECKED — zi I� is GNI�/ HDH A10 CMU ADHESIVE RIGID INSULATION BASE COAT W/ 4.5 OZ. STANDARD MESH TO BE APPLIED THROUGHOUT FINISH COAT E.I.F.S. FLASHING TAPE STARTER TRACK w/ WEEP HOLES flER MEMBRANE LAPPED ONTO FOUNUAIIUN. HLAUL FRIOR TO PLACING ADJACENT PAVING TYP. E.I.F.S. BASE TERMINATION 1 a N.T.S. CONT. METAL FLASHING & COUNTER FLASHING, PAINTED, SEE EXT. ELEV. FOR COLOR SLOPE PREFABRICATED CANOPY ASSEMBLED ON SITE PRESSURE TREATED 1x, SKIM COATED WITH EIFS SEALANT BLOCKING MATERIAL TO BE - DETERMINED, G.C. TO VERIFY WITH ARCHITECT AND CANOPY MANUFACTURER It 2 SECTION DETAIL - PARAPET Scale: 3"=1'-0" REFER TO STRUCTURAL DRAWINGS FOR MORE DETAILS & INFORMATION. EXTERIOR CMU WALL BACKER ROD and SEALANT BACK —WRAP TERMINATION BASE COAT FINISH COAT RIGID INSULATION 1 b TYP. E.I.F.S. AT INSIDE CORNER N.T.S. EIFS OVER VAPOR BARRIER ON CM Vr CONT. SEALANT HIGH SIDE EAVE FLASHING, FASTENING CLIPS & PANEL SYSTEM BY METAL ROOF MANUF. PROVIDE FASTENERS PER METAL ROOF SYSTEM MANUF. SPECIF'S. AWNING FRAME, ESP BRONZE FINISH:" {' I 3/8" DIA. x 4" SCREW INTO WOOD STRUCTURE SPACED PER AWNING MANUF. RECOMMENDATIONS 4 SECTION DETAIL - GUTTER Scale: 3"=1'-0" 1 Z—CLIPS (2"x2"x1/4") AND 3/4% #10 CONCRETE ANCHORS INTO CMU ---- _-..q1/2" (2) 2x6 BLOCKING CONT. — COORDINATE WITH AWNING SUPPLIER n PVC SLEEVE WITH SEALANT TYP. E.I.F.S. FLASHING TAPE 1 C N.T.S. NOTES: 1. MANUFACTURER TO OBTAIN CERTIFIED STRUCTURAL ENGINEER STAMPED DRAWINGS STATING THAT THE INSTALLED CANOPY IS RATED FOR THE LOCAL WIND LOAD ZONE, WITH STATIC LOAD CAPACITY OF 20 PSG IN ADDITION TO THE WEIGHT OF THE STRUCTURE. 2. INSTALL AWNING LIGHTING TO MEET LOCAL CODES. SEE WINDOW HEADER DETAILS SHEET A17 and E.I.F.S. ISOMETRIC DETALS, THIS SHEET, for ADDITIONAL NOTES and INFORMATION 8"x16" CONC. BOND BEAM W/(2) 8" U—BLOCK W/(1) #5 IN EACH (SEE STRUCTURAL) E.I.F.S. INSULATION (BASE COATS and MESH NOT SHOWN for CLARITY) AIR / VAPOR BARRIER and TROWEL APPLIED ADHESIVE NOT SHOWN for CLARITY HORIZONTAL FLASHING TAPE ALUMINUM WINDOW FLASHING 3/8"0 x 4" SCREW THROUGH 1/2 PVC SLEEVE INTO WOOD STRUCTURE STANDING SEAM METAL ROOF AND FLASHING SYSTEM PER METAL ROOF MANUFACT. 1 "xl "x.10" SQ. ALUMINUM TUBING AWNING FRAME AT 4'-0" O.C. OR PER MANUF. RECOMMENDATIONS. 6063—T5 ALLOY —ESP BRONZE FINISH. LIGHT FIXTURE, SUPPLIED BY OWNER & INSTALLED BY G.C. OFFSET CLEAT & F, I" m 9' 4"t BOTTOM OF AWNING 3/8"0 x 4" SCREW THROUGH 1/2" PVC SLEEVE INTO STRUCTURE CJ SECTION DETAIL -AWNING Scale 1 1/7=1'-0" 9:-4:: A.F.F. 0 w 0 D 0 O w w w cm 0 0 z w Q w W x F- Lu U z w z U) w 0 w x -ovum > N V N m Ol N W t' V M M CS ui LL (O (D > M M n @ Q N Z p �= L M p 0 � W W LL I— W 2 Z ry Z a w J p J [Q I! W W d N N Q2 Z M i7 F Z O LL V V _ p N > N > N N O W p �M oN c=i o ai E CO O H Q W J u 0 L.L.: z O I ry w 0 W U I; � S z v' Q w Dove e z 0 ' Q I' Cn (D z J w Q C.L0s 0 a C0 CO 2 rn O W —� 0 2 � ry a Z W L W 0 N A w � Z W N a ~ X F a O Y m _ x J o W c� J4 N �.. (vyv •..v 1i:. LLJ • B98913 'C Wc'sT ............�z�� FLED P� in DEC 2 1 2018 Lj HAROLD DANIEL HUTTER III a FL.REG. 98913 X e —i RELEASE DATE Fov`'l OQt� v —`G ov i I'. 2 f 3 ii 4 5 II4 5 PROJECT NO. 2018-002 }r ISSUE DATE 12/21/18 -I� CHECKED HDH 6 IINITERIIOR ELEVATION 7 INscaITERIIOR ELEVATION 8 INTERIOR ELEVATION ScaA2.0 A2.0 A2.0 9 INTERIOR ELEVATION Scale 3/8"=1'-0" A2.0 10 INTERIOR ELEVATION Scale 3/8"=1'-0" A2.0 SHEET NO. A11 SPECIFICATIONS DIVISION 6: WOOD SECTION 6B: FINISH CARPENTRY GENERAL PROVISIONS 1. SCOPE: INTERIOR CONSULTANT TO FURNISH AND INSTALL EXPOSED WOOD TRIM, MILLWORK, CASEWORK, WOOD CABINETS, PLASTIC LAMINATES, AND WOOD SHELVING. 2. NOTES: A. MOISTURE CONTENT: FINISH WOODWORK MATERIALS SHALL BE KILN DRIED TO THE FOLLOWING MOISTURE CONTENT UNLESS OTHERWISE RECOMMENDED IN THE APPLICABLE "QUALITY STANDARDS" FOR REGIONAL CLIMATE CONDITIONS: INTERIOR WOODWORK - 6% TO 11 % EXTERIOR WOODWORK - 9% TO 12% B. FIELD MEASUREMENTS: ALL DIMENSIONS AFFECTING PREFABRICATED MILLWORK AND CASEWORK ITEMS SHALL BE FIELD VERIFIED PRIOR TO FABRICATION. C. CONDITIONS: PROVIDE PROPER TEMPERATURE AND HUMIDITY REQUIREMENTS FOR WOODWORK INSTALLATION AREAS. INSTALL WOODWORK AFTER THE REQUIRED TEMPERATURE AND RELATIVE HUMIDITY HAVE BEEN STABILIZED IN INSTALLATION AREAS. MAINTAIN TEMPERATURE AND HUMIDITY CONDITIONS UNTIL ACCEPTANCE OF THE WORK BY THE OWNER. 3. QUALITY CONTROL: WOODWORK SHALL COMPLY WITH ARCHITECTURAL WOOD WORK INSTITUTE (AWI) "QUALITY STANDARDS" EXCEPT WHERE OTHERWISE NOTED. 4. SUBMISSIONS: SUBMIT FOUR (4) COPIES OF SHOP DRAWINGS OF ALL CABINETWORKAND MILLWORK ITEMS TO OWNER. MATERIALS 1. WOOD TRIM: PROVIDE BIRCH AS INDICATED ON THE FINISH SCHEDULE IN AWI CUSTOM GRADE I PLAIN SAWN WOOD. FABRICATE WOOD TRIM TO DIMENSIONS, PROFILE AND DETAILS SHOWN, ROUTE OR GROOVE REVERSE SIDE OF TRIM MEMBERS WIDER THAN 4" TO BE APPLIED TO FLAT SURFACES EXCEPT FOR MEMBERS WITH ENDS EXPOSED IN THE FINISHED WORK. SECURE WITH FINISH NAILS STAGGERED AND COUNTER SINK, WITH PUTTY TO MATCH WOOD COLOR. MITER OUTSIDE CORNER AND CONTINUOUS JOINTS. FINISH WITH ONE (1) COAT OF MINWAX PASTE WOOD FILLER AND TWO (2) COATS MINWAX POLYURETHANE FINISH LOW LUSTER. 2. WOOD PANELING: REFER TO FINISH SCHEDULE FOR MATERIAL SELECTION. INSTALLATION PER MANUFACTURER'S INSTRUCTIONS. FINISH WITH TWO (2) COATS OF POLYURETHANE FINISH LOW LUSTER. 3. CABINETS, COUNTERTOPS, AND OTHER MILLWORK: COMPLY WITH AWI QUALITY STANDARDS FOR CUSTOM WORK. A. PLYWOOD: EXPOSED PAINTED- MDO MEDIUM DENSITY OVERLAY CONCEALED - B-C PLYWOOD EXPOSED STAINED - 3/4" BIRCH VENEER PLYWOOD EDGE BAND EXPOSED PLYWOOD EDGES WITH CLEAR WOOD TRIM AND CONCEALED WITH FASTENERS. B. WOOD TRIM: STAIN/ VARNISH, BIRCH WOOD C. PLASTIC LAMINATE: PROVIDE PLASTIC LAMINATE OF THE MANUFACTURER, COLOR, TEXTURE, AND PATTERN AS SHOWN ON FINISH SCHEDULE. 4. HARDWARE: ADJUSTABLE SHELF HARDWARE SHALL BE KNAPE AND VOGT, WALL MOUNTED SHELF STANDARDS WITH HEAVY DUTY BRACKETS AS SHOWN. FINISH ANOCHROME. INTERIOR ELEVATION NOTES: 1. AT ALL OUTSIDE CORNER WALLS - PROVIDE WOOD CORNER GUARDS. * FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION 8'-8" A.F.F. SELF SERVICE DRINK COUNTER PANELING TO CB- 3 SALES AREA ELEVATION Scale: 3/8" =1'4' M-1 MOSAIC TILE WOOD CORNER GUARD (TYP.) P-8 SOFFIT DIGITAL MENU BOARD (BULKHEAD BEHIND TO BE AINTED PAINTED P-8) �. "P" SEAL 5 IER 4" BACKSPLASH--, i R1jEii• '� M-1 MOSAIC TILE CR-1 5 BEVERAGE COUNTER ELEVATION Scale: 3/8" = 1'-0" OPTIONAL WALL MOUNTED CR-1� 2 HALL ELEVATION - KITCHEN DOOR Scale: 3/8" =1'4' FOR MENU BOARD D ABOVE CEILING ON BULKHEAD T-0„ k. F. F.V 4aSALES AREA ELEVATION - DRIVE THRU Scale: 3/8" =1'-0" I �,FRP i PRODUCTION COUNTER I 9'1' A.F.F. 1 HALL ELEVATION - CLOSET Scale: 3/8" = l'-0" A CI••1 P-3-�i N AN 9'-6" oj A.F.F. 9'-4" m O A.F.F. H � O 8'-8" z w _ A.F.F.Of Lu w H WC-1 WOOD CORNER w GUARD (TYP.) z w r WOOD TRIM _ SOLID SURFACE 0 BACK SPLASH w 2'-10" 0 - A.F.F. w 2 H LF1_j P z a H Z w 0 0 0 w U) 4 SALES AREA ELEVATION - KITCHEN DOOR T E o a o e Scale: 3/8" = IA" O H H ------------------- �M r>cn W i N P n E M M a �� `J z . o c E V t y U N a� W W = z U � z i Q W J J p] N J W U � � W C7 r Z O LL a V W W U K 9 C N Lu w z o �o i E a' Z �.�..+"�' p .0 a N n a i r—c ` 1 1 AP-2 WALL GRAPHIC I L--J WOOD CORNER GUARD (TYP.) CR-1 _ 1 1 1 1 1 (EXTEND PANELING TO 1/2" j ABOVE COUNTERTOP 34 AFF j 1 1 1 1 0 1 1 1 fWS-1� fWS-1 � N WS-1-,_ s 1 \-CB-1 6 DINING ROOM ELEVATION Scale: 3/8" =1'-0" L l�. L�,(. ICLCVIJIVIV or VYYIVCR P-2 HALL CLOSET CCD Fn L- 1 I o L O / 1 AP-10 -� PAINTED "P" SEAL � '-- � � I WOOD CORNER GUARD (TYP) . I AP-7 WALL I GRAPHIC L — — J AINTED "P" SEAL VIOGN" ST-1 D, S IN C= ST-1 W D, STAIN m R _ rf„ I O o i N -WS-,� •1 A10 T [[ T `CB-1 GCB-1 Y� 8 DINING ROOM ELEVATION Scale: 3/8" =1'4' SCR-1 9 -4" A.F.F. 9,-4„ Z W A.F.F. w 0- O O J a_ � Q U) Co Lu w Lij J v O J C W H LLI W Q Z U U J w H Z N a 2 a U) LL� COD SELF SERVE ••••• DRINK COUNTER- •'•O ON LEGS 0 gr • PJ.., y > per• 13 'U --------------------� w C' • k' CB-, CB-1 TILE BASE 0 2 � /��RED•P�G�� WALL BEYOND Al 4 5 DEC 2 1 2018 aHAROLD DANIEL NUTTER III X FL. REG. 98913 EQ. L EQ. i� P-2—'_� r - --i AP-1 WALL GRAPHIC I � L--J CD fws-1� N [—I P-2 F r. OOD CORNER GUARD (TYP.) 7 DINING ROOM ELEVATION Scale: 30 =1'4' CB-1 .0 A.F.F. r---� AP-5 WALL GRAPHIC I L--J 17 it 4`�E� F NN 0rco 13 w I' U) —i RELEASE uNic 1 2 3 4 5 Z O Q Lu Li Of LLJ PROJECT NO. 2018 002 ISSUE DATE 12/21/18 8'-8" A.F.F. COUNTER SC 7'-0" B/BULKHEAD r r Tn POODNKIATr 1 DIGITAL MENUBOARD ELECTRICAL RECEPTACLE LOCATIONS Scale: 3/4" = P-0" 91-41I A.F.F. PEN PR ME BO FRON COUN c r. 9'-6" A.F.F. ;LNG HT. BEYOND 9'-4" A.F.F. CLNG HT. * FOR REFERENCE ONLY 0 I N 2 DIGITAL MENUBOARD MOUNTING HOLE LOCATIONS Scale: 3/4" = T-0" * FOR REFERENCE ONLY 1 l i, V1%ll iX"I 9'-6" A.F.F. CLNG HT. Y 9'-4" A.F.F. CLNG HT. 7'-0" A.F.F. B/BULKHEAD 0VI 00, GOO m Lu U O d' a w w m O O z w } Lu x I -- UP U z w x Z C7 N Lu w F- 0 Z ¢ ca I- z Lu 77, O 0 w w w O F- w I- x cD w o_ O a- x w O J Z ¢ x Of Q_ O U cn F U) w uj w w w J U) m w a w w cn J m N W M O, OJ V M M [+J LL w y m 7 M M V W W ►— w if U U t Q W I[ U o J m C J U � Z (n O Z z Z a LL o m o o LLJ Q U ^ F H NN N U)_ O W F- w N y N N U a E Q NUJ J Q Q- ti t: si U Z W o Q m J U) W J a ¢ x U Q ui w F o coo LL H w J U I!i 0 Q W > x o w Y x H O U POPeYeS w if ry O J_ Q i J who Lu w Z ml- N C Q CV 116 L O 0 ri LQ PR W H DEC 2 1 2018 HAROLD DANIEL NUTTER III FL.REG. 98913 C / z O Lu J Lu 0 Q O Z Lu � _0 0 K[L[HJC URIC 1 2 3 3 4 �I 5 6 PROJECT NO. L II 2018-002 ISSUE DATE 12/21/18 DRAWN CHECKED GM HDH 3 PRE -SALE BOARD ELEVATION (@ FRONT COUNTER) Scale: 3/4" =1'-0" 4 MOUNTING BRACKET DETAIL (SIDE/REAR N.T.S. AT2a 11 bVLAKLKJ 1 KITCHEN ELEVATION Scale: 318" = V-0" I7VARV 9 INSULATE CLG. .-------------- A16 S.S. PANEL, FURNISHED AND INSTALLED BY G.C. PENETRATIONS OF ( ; GREASE LINE REFRIGERANT LINES OUTLET FOR GREASE POS TERMINAL BOX. 1 1 LINE HEAT TAPE PROVIDE 4" CONDUIT THRU TO CABINET B10 o GREASE ALARM B65 ® I TIME CLOCK---,, :Ell Llt� El O El �El i I 10.3 1 I � AV- 1 1 Ll I uT 4 KITCHEN ELEVATION Scale: 3/8" = 1'-0" PANEL, AND BY G.C. 5 KITCHEN ELEVATION Scale: 3/8" = V-0" FIRE ALARM CONTROL PANEL m C A B 0 I ro DP CONVENTIONAL ELECTRICAL PANELS SHOWN 2 KITCHEN ELEVATION Scale: 3/81'= V-0" 6 KITCHEN ELEVATION Scale: 3/8" = V-0" 18GA. S.S. WALL PANEL AT MOP SINK DUPLEX LOCATED INSIDE THE WALL SURFACE MOUNT MOP SINK SET IN SEALANT BED El 7 KITCHEN ELEVATION 4 REAR DOOR 9 INTERIOR ELEVATION 20.6 20.6 20.7 I € �px5:a^ rss:.rar�as� tT.'sz�aa�s � sz� I I' I I ! I 11 INTERIOR ELEVATION - COOLER Scale: 3/8" = V-0" 1 2 INTERIOR ELEVATION - COOLER Scale: 3/8" = V-0" O O J Z Q N O O O I J O d Q (El 0.2 3 KITCHEN ELEVATION Scale: 3/8" = V-0" _,__�FRP� :41•� COUNTER a I `* ,ACCESS PANEL ' J-BOX 0 24" A.F.F. WATER SHUT OFF 0 12" A.F.F. 16 GA. S.S. SPLASH PANEL 30" DEEP x 24" HIGH, FURNISHED & INSTALLED BY G.C. ATTACH S.S. PANEL TO SHELVING POLES ,u TRIM LEGEND EDUPLEX RECEPTACLE SPECIAL PURPOSE RECEPTACLE a TELEPHONE OUTLET DATA OUTLET TELEPHONE ONLY OUTLET DATA ONLY OUTLET JUNCTION BOX WATER CONNECTION NOTES: 1. DIMENSIONS ARE TAKEN TO TH CENTER LINE OF THE JUNCTIQQii BOXES. (VERT. & HORw%j%` 2. PAPER TOWER DIS �wvY" SAN JAMAR 4TJ 490gry�ol��1y� ` • 1 FURNISHED AND INSIEW EIRN, G.C. 3. SOAP DISPENSER FURNISHED I OWNER INSTALLED BY G.C. ONi N OJ L1J a V z a o 0d 0 E U N d W LJJ F— LJJ = Z_ U (D Q W j' k J r O J m C/) J el W W c0 O O W Z W O V p J N Z W W U 0 O N N N V O 1 N �M U Lu ~ W z Z oN O n N N ry U O m 0 N E Q N a N C N C/) p w U p O a w Of w Co O H O z w WOOD CORNER ¢ GUARD (TYP.) w H uP U z w x z SOLID SURFACE BACKSPLASH o w x H p z F zi U i p U j w F_ o000 0 O it H S LLJ Lu k w a O 20.6 O 's O d 4i Q Lu w ;! U) co x w _I H Q U >� I ¢ z . CD � W ;I U p C) CL N w Z ;� Q ¢ Of Y OU U) ' U)of • Lu '9t� ggggl co � ED F r 11 w$I x Lu w -i r RELEASE DATE - DEC 2 1 2018 HAROLD DANIEL NUTTER III FL REG. 98913 F'ttVJtV I NU. jp 2018-002 ISSUE DATE 12/21/18 DRAWN CHECKED - GM HDH SHEET 10 INTERIOR ELEVATION Scale: 3/8" = V-0" 1 3 INTERIOR ELEVATION - COOLER Scale: 3/8" = V-W 14 INTERIOR ELEVATION - COOLER Scale: 3/8" = V-0" SUSPENDED CEILING� 9'4' A.F.F. ACCENT TILE BOTTOM OF SOFFITi-6, b'-b" A.F.F.14t_ 1 x2 WOOD ACCENT TRIM CAULK, CONT, NOTE: SEE INTERIOR FINISH SCHEDULE FOR FINISHES COOLER DOOR---------, SWEEP GASKET SLOPE SETTING BED 1/8" PER FOOT TO QUARRY TILE TO COOLER DOOR BUILDING SLAB 7 SECTION DETAIL - W.I.B. DOOR Scale: 1-1/2" = V-0" 11 2 WALL CLEARANCE NOTE: SEE SHEET S-1 FOR FOUNDATION DETAILS AND ADDITIONAL NOTES. G.C. TO COMPLY WITH ALL W.I.B. MANUFACTURER RECOMMENDATIONS FOR PREPARATION AND INSTALLATION OF W.I.B. SLAB. WALL COOLER REFRIGERATION SHALL BE SIZED TO MAINTAIN 34 DEG F. FREEZER .--:�--W.1.13. REFRIGERATION SHALL BE SIZED TO MAINTAIN -10 DEG. F. WALK-IN COOLER SHALL BE PROVIDED WITHOUT FLOOR. WALK-IN FREEZER SHALL BE PROVIDED QUARRY TILE & BASE WITH 4" INSULATED FLOOR AND INTERIOR RAMP AT DOOR. THE WALK-IN MANUFACTURER WILL PROVIDE: SLOPE SETTING BED 1) THE WALK-IN COOLER & FREEZER 2) REFRIGERATION EQUIP. SIZED TO MEET POPEYES REQUIREMENTS, 1/8" PER FOOT TO FACTORY ASSEMBLED AND WITH LOWAMBIENT CONTROLS, DOOR INCLUDING ALL WIRING, REFRIGERATION PIPING, W/ REMOTE UNITS MOUNTED ON S.S. RAILS LOCATED ON THE ROOF, AND READY FOR FINAL CONNECTION TO ALL NECESSARY UTILITIES. 3) DELIVERY OF THE BOXES 4) FLASHING KITS AS NOTED 5) CONTRACTOR TO INSTALL WALK-IN BOX AND REFRIG. • SEE STRUCTURAL FOR IT SHALL BE THE RESPONSIBILITY OF THE G.C. TO CONTACT WALK-IN BOX PROVIDER AND OBTAIN A COPY OF THE SHOP DRAWINGS FOR THIS PROJECT FOUNDATION PRIOR TO ROUGH IN OF UTILITIES FAILURE TO OBTAIN SHOP DRAWINGS PRIOR TO ROUGH IN WILL NOT RESULT IN EXTRA CHARGES TO THE OWNER FOR RELOCATION OF UTILITIES 10 SECTION DETAIL - W.I.B. WALL 11WALK-IN COOLER BOX NOTES CAULK, CONT. NOTE: —BUILDING WALL INSTALL ACCENT TRIM AFTER GRAPHIC APPLIED. CAULK CONTINUOUS 1/2" SOLID SURFACE (SS-1) ON - 3/4" PLYWOOD (RE: FINISH CORIAN BACKSPLASH SCHEDULE CAULK CONT. '- 2-9 2x2 CONT, BLOCKING SUPPORT-, L 1-1/2"0 GROMMETED HOLE FOR TOP (PAINTED WHITE) ELECTRIC CABLES AT P.O.S. ONLY WALK-IN WALL--- FRP TRIM - - 2-1/2" x 1/2" BLOCKING FIELD FABRICATE MOUNTING--, BRACKET FOR CASH DRAWER 2x4 WOOD STUDS @ 16" O.C. SEE INTERIOR ELEVATION FOR —MOSAIC TILE ON DUROCK TYP. LOCATION OF ELEC. -C� RECEPTACLE -4 `2" EXPANSION GAP SHELVING LEGS. CUT LEGS FOR--- 2x4 WOOD BLOCKING IN WALLAS < � CLEARANCE REQUIRED FULL LENGTH .040 ALUM. FRP ON 1/2" PLYWOOD--- QUARRY TILE STRAIGHT TOP CLOSURE ANGLE/WALL END CAP COVE BASE (CB-1) FULL LENGTH .040 ALUM. CLOSURE, W/ HEMMED EDGES W/ _21 ANGLE W/ HEMMED EDGES W/ SILICONE BEAD CONT. EACH ADJUSTABLE SS ANCHOR TO COUNTER TOP & TO LEGS SUPPORT. 1/2" DUROCK AT BASE OF SILICONE BEAD CONT. EACH SIDE SIDE QUARRY TIL E (QT-2) FLOOR SUPPLIED AND (RE: FINISH SCHEDULE) COUNTER WALK-IN WALL INSTALLED BY GC ANCHOR P.T. 2x4 AT FLOOR NOTE: SEE INTERIOR FINISH SCHEDULE FOR FINISHES BUILDING WALL SECTION FRONT COUNTER FLASHING DETAIL W.I.B. Kale: 9 FLASHING DETAIL - W.I.B. GENERAL NOTE: 1 HEIGHT OF OPERATING PART AP-14 v OF DRINK MACHINES AND WC-1 OTHER DISPENSING DEVICES CAR SIDING SHALL COMPLY WITH SECTION 308-FBC-A AND 2010 ADA PROVIDE WOOD BRACE CENTER ------------ FINISH ENTIRE WALL INCLUDING PAINTING LINE OF COUNTER PRIOR TO INSTALLATION OF MILL WORK 3/4" PLYWOOD FACING W/ F PLASTIC LAM. FINISH TO MATCH DOORS 1/2" PLYWOOD CABINET FLUSH - MOUNTED DOORS W/ PLASTIC LAM. FINISH W/ (4) STAINLESS STEEL, WIRE PULLS AND PIANO HINGES, (2) PER DOOR ro S.S. LEGS 1' 3" 4" BACKE 1" DIA. HOLE FOR WIRING 0 Lu u- 0 Z < b LD j T w X: 2 o 0 < o< 0 11 3'-8- VERIFY IN FIELD 2 INTERIOR ELEVATION - SELF -SERVE COUNTER Scale: 3/4" = V-0" 4'-72�' SALES 'A" I cc 1" DIA. HOLE FOR WIRING iv 4" BACKSPLASH UNDER COUNTER CUP DISPENSERS KITCHEN 4 ENLARGED PLAN - FRONT COUNTER CUT-OUTS Scale: 3/4" = V-0" 2' 3 FRONT COUNTER ELEVATION Scale: 3/4" = V-0" NOTE: SEE FINISH SCHEDULE FOR MATERIAL LIST, A 4 T REGISTER TTREGISTER = r� I �= I I I I m m OMNI "m 0.1 1/2 " PRE-FAB SOLID SURFACE COUNTER TOP. VERIFY W/FINISH SCHEDULE ACTUAL COLOR OF COUNTER ADJUSTABLE 1 1/2" S.S. LEGS --/ UNDERMOUNT SHELVING SUPPLIED SUPPLIED AND INSTALLED LUNDER COUNTER CUP BY KITCHEN EQUIPMENT VENDOR BY G.C., TYP. DISPENSERS, INSTALL PER AND INSTALLED BY C.C., TYP. MANUF. INSTRUCTIONS, 5 INTERIOR ELEVATION - FRONT COUNTER REAR ELEVATION Scale: 3/4" = V-0" 3" u 0 u < I z 0 No 0 0 0 w u NOTE: DIMENSIONS SHOWN ARE ACTUAL DIMENSIONS 6 WALK-IN FLOOR PLAN Scale: 1/2" = 1'-0" 3'-5)/2" 05 i 12KITCHEN ELEVATION Scale: 3/8" = 1'-0" 3'.' l'-8" 3" 11-81, 3" 11-111, EVAPORATOR L COOLER y 1^0 �Ll 4� FREEZER F - - - -1 EVAPORATOR M SELF CLOSING AINGES 2" DIAL THERMOMETER DILOT SWITCH 34" FLUSH BOTTOM DOOR UETAL CLOSURE PANEL BETWEEN TOP OF COOLER AND CEILING STAR TREAD KICK PLATE COORDINATE PANELS WITH ELECTRICAL Co b 1. 1.1 � 7 Al 4 Fovk Mp� �N GoDLV f- BoGGG' S ui ui Lu Lu 0 (D < Lu o Lu z (D Cf) 0 Z z Z < ❑ LU R Cr zoo < C0 DEC 2 1 HAROLD DANIEL HUTT[ x0- it !� w tq; 2018-002 ISSUE DATE — 12/21/18 DRAWN — r, A14 U. U. L LC 1 ENLARGED RESTROOM FLOOR PLAN Scale:l/2"=1'-0" ALL DIMENSIONS THIS SHEET ARE FROM FINISHES, U.N.O. SPECIFICATIONS: DIVISION 10: SPECIALTIES SECTION 10A: TOILET ACCESSORIES GENERAL PROVISIONS 1. SCOPE: INSTALL TOILET PARTITIONS WHERE APPLICABLE, TOILET ACCESSORIES, AND RELATED HARDWARE AS SHOWN ON PLANS OR INSTALLATION DRAWINGS. 2. SUBMISSIONS: PROVINN. L ION DRAWINGS TO OWNER'S REPRESENTATIVE SHOE AND LOCATION OF EACH COMPONENT AND RP I SIZES AND MOUNTING HEIGHTS. LABEL ALL COMPONSPOND TO INSTRUCTIONS FOR EASE OF INSTALLAT MATERIALS - 1. DOORS FOR TOILET COMPARTMENTS WHERE APPLICABLE WITH STUD WALL PARTITIONS SHALL BE 3/4" X 58" HIGH TOILET STALL DOORS WITH STANDARD HINGES #502 CATCH SLIDE SURFACE STRIKE #5140 FOR OUTSWINGING DOORS, AND #5260 SURFACE STRIKE FOR IN -SWINGING DOORS, COAT HOOK WITH RUBBER BUMPER AT 48" O.C. 2. STALL DOOR HINGE JAMB: 1-1/4" X 1-1/4" X 8'-0" MILL FINISH ALUMINUM TUBE HINGE JAMB POST FOR TOILET STALL DOORS. PRE- DRILL FOR #12 SCREWS @ 8" O.C. 3. PANELIZED TOILET COMPARTMENTS & DOORS (WHEN SHOWN) SHALL BE MARLITE FLOOR -MOUNTED, OVERHEAD -BRACED TOILET PARTITIONS AND /OR FLOOR -MOUNTED, CEILING -BRACED URINAL SCREEN BY MARLITE WITH STAINLESS STEEL PILASTER SHOE COVERS. FINISH 927 FOLKSTONE(GRAY), MCP LAMINATE. DOORS TO HAVE COAT HOOK WITH RUBBER BUMPER. 4. ACCESSORIES REFER TO DRAWINGS. PERFORMANCE 1. INSTALL PARTITIONS, ACCESSORIES, AND HARDWARE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION DRAWINGS. RESTROOM ACCESSORIES SCHEDULE QUANTITY ITEM 2 R 1 0 WALL MOUNTED MIRROR, CHANNEL FRAME 18"x36" - GAMCO C-18x36 2 R20 SURFACE -MOUNTED DOOR BUMPER - BOBRICK B-6877 4 R 22 HEAVY DUTY CLOTHES HOOK - BOBRICK B-2116 2 R 30 SOAP DISPENSER, SURFACE MOUNT - BOBRICK B-4112 (OPTIONAL) 2 TM ROLL TOILET TISSUE DISPENSER - BOBRICK B-2890 2 R 50 GRAB BAR, STRAIGHT, SNAP FLANGE, 36" - GAMCO 150-S x 36" 2 R 51 GRAB BAR, STRAIGHT, SNAP FLANGE, 42" - GAMCO 150-S x 42" 0 R 52 GRAB BAR, STRAIGHT, SNAP FLANGE, 18" - GAMCO 150-S x18" 1 R 60 SANITARY NAPKIN DISPOSAL, SURFACE MOUNT - BOBRICK B-270 2 N 80 BABY CHANGING STATION, SURFACE MOUNT - KOALA KARE KB101-00 2 N81 WALL MOUNT HAND SINK, RESTAURANT INTERIORS, INC. R-2030 2 N 82 RECESSED PAPER TOWEL DISPENSER AND WASTE RECEPTACLE, E30BRICK B-43944 2 N 83 RECESSED ELECTRIC HAND DRYER, BRUSHED STAINLESS STEEL - XLERATOR XL-SB 2 N 84 TOILET, FLOOR MOUNT, TANK TYPE - AMERICAN STANDARD 2467.016 ALL RESTROOM ACCESSORIES FURNISHED AND INSTALLED BY CONTRACTOR, EXCEPT SOAP DISPENSER. ACCESSIBILITY NOTES: ADA/ANSI A117.1 1. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN SHALL BE DISPLAYED AT ALL ACCESSIBLE RESTROOM FACILITIES AND AT ACCESSIBLE BUILDING ENTRANCES UNLESS ALL ENTRANCES ARE ACCESSIBLE. INACCESSIBLE ENTRANCES SHALL HAVE DIRECTIONAL SIGNS INDICATING THE ROUTE TO THE NEAREST ACCESSIBLE ENTRANCE. 2. RECEPTACLES ON WALLS SHALL BE MOUNTED NO LESS THAN 15" ABOVE THE FLOOR. EXCEPTION: HEIGHT LIMITATIONS DO NOT APPLY WHERE THE USE OF SPECIAL EQUIPMENT DICTATES OTHERWISE OR WHERE ELECTRICAL RECEPTACLES ARE NOT NORMALLY INTENDED FOR USE BY BUILDING OCCUPANTS. 3. WHERE EMERGENCY WARNING SYSTEMS ARE PROVIDED, THEY SHALL INCLUDE BOTH AUDIBLE AND VISUAL ALARMS. THE VISUAL ALARMS SHALL BE LOCATED THROUGHOUT, INCLUDING RESTROOMS, AND PLACED 80" ABOVE THE FLOOR OR 6" BELOW CEILING, WHICHEVER IS LOWER. 4. DOORS TO ALL ACCESSIBLE SPACES SHALL HAVE ACCESSIBLE HARDWARE (i.e. LEVER -OPERATED, PUSH -TYPE, U-SHAPED) MOUNTED NO HIGHER THAN 48" ABOVE THE FLOOR. 5. FLOOR SURFACES SHALL BE STABLE, FIRM, AND SLIP -RESISTANT. CHANGES IN LEVEL BETWEEN 0.25" AND 0.5" SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2". CHANGES IN LEVEL GREATER THAN 0.5" REQUIRE RAMPS. CARPET PILE THICKNESS SHALL BE 0.5" MAX. GRATINGS IN FLOOR SHALL HAVE SPACES NO GREATER THAN 0.5" WIDE IN ONE DIRECTION, DOORWAY THRESHOLDS SHALL NOT EXCEED 0.5" IN HEIGHT. 6. GRAB BARS REQUIRED FOR ACCESSIBILITY SHALL BE 1.25"-1.50" IN DIAMETER WITH 1.5" CLEAR SPACE BETWEEN THE BAR AND THE WALL. 7. ACCESSIBLE WATER CLOSETS SHALL BE 17"-19" FROM FLOOR TO THE TOP OF THE SEAT. GRAB BARS SHALL BE 36" LONG MINIMUM WHEN LOCATED BEHIND WATER CLOSET AND 42" MINIMUM WHEN LOCATED ALONG SIDE OF WATER CLOSET, AND SHALL BE MOUNTED 33"-36" ABOVE THE FLOOR. 8. ACCESSIBLE URINALS SHALL BE STALL -TYPE OR WALL HUNG WITH ELONGATED RIMS AT A MAXIMUM OF 17" ABOVE THE FLOOR. 9. ACCESSIBLE LAVATORIES SHALL BE MOUNTED WITH THE RIM NO HIGHER THAN 34" ABOVE THE FLOOR AND A CLEARANCE OF AT LEAST 29" ABOVE THE FLOOR TO THE BOTTOM OF THE APRON. 10. ACCESSIBLE SINKS SHALL BE MOUNTED WITH THE RIM NO HIGHER THAN 34" ABOVE THE FLOOR AND A CLEARANCE OF AT LEAST 27" HIGH, 30" WIDE, AND 19" DEEP UNDERNEATH SINK. THE SINK DEPTH SHALL BE 8.6" MAXIMUM. 11. HOT WATER AND DRAIN PIPES UNDER ACCESSIBLE LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER 12. ACCESSIBLE LAVATORIES AND SINKS. ACCESSIBLE LAVATORIES AND SINKS SHALL HAVE ACCESSIBLE FAUCETS (i.e. LEVER -OPERATED, PUSH -TYPE, ELECTRONICALLY CONTROLLED.) 13. WHERE MIRRORS ARE PROVIDED IN RESTROOM, AT LEAST ONE SHALL BE PROVIDED WITH THE BOTTOM EDGE OF THE REFLECTIVE SURFACE NO HIGHER THAN 40" ABOVE THE FLOOR. GENERAL NOTE: 1.) SEE INTERIOR FINI H SCHEDULE (SHEET A2) Cy r m T-3 M-2 MOSAIC TILE i ` UKAIN CUU I _L PER MFR. FICATIONS r MENS RESTROOM E(c B i —' A ADA APPROVED DRAIN BOOT 2 RESTROOM INTERIOR ELEVATIONS Scale: 1l2"=1'-0" 0 J U_ D INSTALL PEf SPECIFICA P-7 T-3 EN ME- ADA— H APPROVED DRAIN BOOT WOMENS RESTROOM ADA APPROVED DRAIN BOOT M-2 MOSAIC TILE T >-7 T-3 /L0 Co L0 Cr Lu v W ui I- Lu ZI''� 0�/ U L.L� Z Lu U o J M � J U m W K O N N O z U M z m LLC LLIz W U D N W Lu Z N N = p N E U � Q Q N C/) I] W U 0 O LU w w w CID O H- I— O z w w x H- uP U Z W 2 Z CD U) W 0 D_ w 0 z a z z O U w O H U CD Z W w O o_ O J 0- Q Of U) U) w m w J O W 0 LL J Q z t N W U ~ � CV w_ rZ Lu w d a o0 �0 DE ,. Ld S J H w W H w •i — `t R96913 c �J U) I " 1 2018 LU HAROLD DANIEL HUTTER III X FL.REG, 98913 W CIO., ... ._ ... Zi r RELEASE DATE RE IV WED FOR CODE COMpIJAW ST. LUCIE COUNT BpCC PROJECT NO. 2018-002 ISSUE DATE 12/21/18 iI DRAWN CHECKED GM HDH l SHEER(r�-- 7tl 5 PROTECT SYRUP LINES FROM TRUSS ANGLE BUNDLED SYRUP LINES & FILTERED WATER LINE BOTTOM CHORD OF ROOF TRUSS NOTE: SYRUP LINE BUNDLE (OWNER FURNISHED, AND INSTALLED) 1 SYRUP LINES IN ATTIC SPACE Scale: 3/4" = V-0" RH1➢ FRP OVER 1/2" CDX PLYWOOD FRP OVER 1/2" CDX PLYWOOD FRP J CHANNEL MOP SINK FAUCET, SEE j I 18 GA. S.S. BACK WA PLUMBING , :� PANELS TO 5'-0" AT DRAWINGS. CoNOTE: ` MOP SINK SIZED F PLUMBING FIXTUF I� SCHEDULE(SHEE 2x8 STUD WALL tt 6-0" HIGH 18 GA. S/S PANE ' I @ ALL CAN WASH WALLS 41 /'/ GRADE (MARINE) PLYW00 HEIGHT FRP ABOVE 6 a BE ONE PIECE BENT @ CO HOLES FOR FAUCET & VAL INSTALLATION. NO SEAMS SILICONE CAULK @ EDGE; TIGHT SEAL. DRAIN PIPE, REFER TO PLUMBING SHEETS 6 ELEVATION AT MOP SINK Scale: 3/4" = V-0" 2 NOT USED 7 ELEVATION AT MOP SINK Scale: 3l4" = V-0" 2'-10" A.F.F. TOP OF TRIM 1x4 MAPLE RAIL STAIN MARLITE WS-1 3 SECTION DETAIL - CHAIR RAIL Scale: 6" = V-0" NUTONE MODEL# 672R EXHAUST FAN 4" PVC CONDUIT THRU SIDEWALL TO POS TERMINAL BOX (CHORD. LOCATION OF CONDUIT IN FIELD) LAMINATED SHELVES BY NEVAMAR COLOR: STUDIO WHITE MATRIX (MR-7-1T TEXTURED) K&V #87 AND STANDARDS (42") W/ #187LL ANO BRACKETS (18") THERMOSTATS (3) LIGHT SWITCHES BANKS BEND S.S. OVER BASE TILE 1/4" M-11 S/S TABLE WITH MIN. TYP. REINFORCED TOP CAULKING HOLD-UP BUTTON Z-0" EN I -S' 4 NOT USED C NOT USED 8 MILLWORK SECTION AT OFFICE Scale: 3/4" = V-0" PROVIDE WOOD BLOCKING FOR WALL CABINET, TYP. 1" CLEAR SPACE BETWEEN BACK OF SHELF AND CABINET WALL I I b FILE CABINETS ON WHEELED PLATFORM OR CASTERS 9 MILLWORK ELEVATION AT OFFICE Scale: 3/4" = 1'-0" o R Z R m M m m W O C l \ v M N d U m W LL1 I— ui �g' = U V llZnn 91 ); a= Z gi < LLB KE U n o 00 � J W U � � W Z Lu 0 O -V' J N Ur Z w 0� ZLu @ LL O o� N H p >^� � O � w z M 0 N . E N O Q g NWQ_ o ; Lu U I ZD O d Lu Lu m o' U � Z z LLI o J m Q I < w w E- w 0 w ,: 3ii LI_I J Q L1-I = U Q w C H r- = h LLj3 w z z 0 Q d � LL G O = H of w W w L1J U r C cN U 0 Z F- .. ¢ Z U w Lu S H n p o o c 5 ' O H H O Z W Q ry 0 O '! J a '' Q a w � U) I- W J a O w I u W u Q p Z 0 0- CN C u Z LU O 2 w S. v a CL J Et u CD r S 0 Cf) y. O U) Lu Lu g8f Lu Lu 9�cs Lu >i U) O Lu HAROLD DANII X FL. REG Lu N RELEASE UAIL 1 2 3 4 5 PROJECT NO. 2018-002 161:m����.",�����,�,,,,,,,Y,,,,,, ,,,,, ,,, , ,,Y....,.. . ISSUE DATE 12/21/18 lOnN E C®pE C E%CC ST • LV BpCC DOOR TYPES TEMPERED GLASS w w w w w > > > m > > hi 0 0 0 0 0 o x U C) °P C) U U 0 SCHEDUL SCHEDULE SCHEDULE'..SCH'' EDU I SCH.. EDULE i. NARROW FRAME METAL DOOR SOLID CORE SOLID CORE FLUSH PAIR TYPE A TYPE B TYPE C TYPE D TYPE E STOREFRONT 1-3/4" FLUSH DOOR 1-3/4" WOOD DOOR, 1-3/4" WOOD DOOR, 1-3/4" WOOD DOOR, TYPE SF-1 TYPE HM-1 BIRCH BIRCH BIRCH ('0'INDICATESOPERATIONAL DOOR) QUANTITY FRAME DOOR SCHEDULE CO m Lu LU = a w ? DETAIL 0 H D_ _U 0- OO = O U < z U UJ U F- J of 2 MARK SIZE DOOR FRAME 03 H U Ow CO OJ a- Y > 0=,. _ to _ U) H � 3'-0" X T-0" (PAIR) TYPE A SF-1 3 PR 1 1 1 1 1 - 2 1 B 2B1,2 3C AA 2� 3'-0" X 6-8" TYPE C HM-I 1.5 PR - _ _ _ _ _ _ 4 1 D 2D 3Q T-0" X T-O" TYPE A SF-1 1.5 PR 1 1 1 1 1 - - - - - 2 1 B 2B1,2 3C AA ® T-6" X 7'-0" TYPE B HM-1 1.5 PR 1 1 1 1 1 1 2 1 - 1 IC 2C 3C BB �5 3'-0" x 6-8" TYPED HM-1 1.5 PR 1 1 1 - - - 2 - 1 EA. 3 1 D 2D - © T-O" X 6'-8" TYPE D HM-1 1.5 PR 1 - 1 1 - - 2 - 1 EA. 3 ID 2D - �7 1'-6" X 6'-8" (PAIR) TYPE E HM-1 1.5 PR 1 - - 1 - CC ® T-O" X 6'-8" DOORS BY COOLER MANUFACTURER - SEE SHEET A-13 09 V-0" X V-8" DOORS BY COOLER MANUFACTURER - SEE SHEET A-13 REMARKS: SPECIFICATIONS. AA: YKKAP -FRAME: YES 45F-S FL12926.R2 / DOOR: 20D FL5851.R5 BE: CECO -FRAME: ZHDL.R27576 / DOOR ZHCW.R27575, FL 4553.R10 CC: ASA ASTRIGAL ON RIGHT DOOR; HANDLE ON LEFT - H4101 FLUSH BOLT ON INACTIVE LEAF HARDWARE SET NO. 1: (LOCKNET SERIES DOOR PACKAGE) DIVISION 8: DOORS, WINDOWS AND GLASS SECTION 88: INTERIOR WOOD CORE DOORS AND FRAMES DOOR FRAME & HARDWARE INCLUDING VISION PANEL W/ FLAP, CONTINUOUS HINGE. GENERAL PROVISIONS HEAVY DUTY CLOSER AND PANIC HARDWARE ORDERED THROUGH LOCKNET (800) 8 1 EA. 7 1. SCOPE: FURNISH AND INSTALL ALL INTERIOR WOOD CORE 1 EA. T-6" X T-0" X (5-7/ X 16 6-3 "G60 GALVANIZED GA. X 6 SECURITY DOOR DOORS AND RELATED ALUMINUM FRAMES. REFER TO 1 EA. WELDED X IN PLACE (5E E OR 1/4" X) JAMB DEPTH X 14 RE X ER GALVANIZED NATIONAL ACCOUNT DIRECTORY. X WELDED IN PLACE EOA X 1/4" X 2-1/2" HR PLATE SPREADER BAR X 4-SIDED WELDED DOOR FRAME X FACTORY FINISH PAINTED 8 EA. 3/4"0 COVER PLUGS (BLACK) MATERIALS 1 EA. AIR LOUVER VLF-IG-PVC-1/2" LEXAN - 9" X 9" GALVANIZED SECURITY VISION 1 EA. PEMKO CDHFM82SLF-HD FULL MORTISE CONT. GEARED ALUM. HINGE X 628 1. DOORS ARE WOOD CORE SOLID DOORS. SEE DOOR SCHEDULE 1 EA, SECURITY LATCH GUARD X FULL LENGTH X TORX SD/ST SMS X FACTORY FINISH FOR SIZE, MATERIAL, HARDWARE, AND FINISH. FRAMES SHALL 1 EA. ARROW 1250S X EO X AL EXIT DEVICE BE HOLLOW METAL AND FINISHED PER FINISH SCHEDULE. 1 EA. DORMA 8616 X DS X FCOV S SN1 X AL CLOSER 1 EA. ROCKWOOD 24" X 40" X .050 X US32D X SECURITY TORX SO/ST SMS 2. SEE HARDWARE SCHEDULE FOR HARDWARE AND ARMOR PLATE ON PUSH SIDE 1 EA. PEMKO 171A X 42" X DOUBLE NOTCH CUT ENDS X THRESHOLD MANUFACTURERS. 1 EA. PEMKO 346C X 46" AL OVERHEAD RAIN DRIP X SECURITY TORX SD/ST SMS 3. SEE SECTION 10A FOR TOILET STALL DOORS WHERE 1 EA. PEMKO 221APK X 42" AL COMBINATION KICK PLAT & DOOR SHOE X TORX 1 SET. P8512 X CONT. PERIMETER WEATHER SEAL (BLACK) APPLICABLE. 1 EA. INSTALLATION KIT (PER LOCKNET) 1 EA. CARDBOARD PACKAGING (2 PIECE BOX) PERFORMANCE 1 EA, DELIVERED ON FULL LENGTH WOODEN PALLET GC TO PROVIDE AND INSTALL HOLD OPEN 1. INSTALLATION: INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. CAULKAROUND HARDWARE SET NO. 2: (BY YKK AP AMERICA INC.) ABUTTING EDGES WITH CLEAR SILICONE. DOORS AND FRAMES SECTION 8C: STEEL DOORS AND FRAMES QTY PART # FINISH MODEL DESCRIPTION 1 49111DOR YB5N YKK AP #20D 3' x T O/P OFFSET PIVOTS, HBR RH GENERAL PROVISIONS 1 92115FTR YB5N 2" x 4-1/2" Tx 7' O/P, FRAME, WITRANSOM, RH 1 aet 1aDOP YB5N 20D 6' x T OlP, OFFSET PIVOTS, HER PR 1. SCOPE: THE GENERAL CONDITIONS, SUPPLEMENTARY 1 92118FTP YB5N 2" x4-1/2" 6' x T O/P, FRAME, WITRANSOM, PR CONDITIONS, AND APPLICABLE PORTIONS OF DIVISION I OF THE 3 P61205 335 SM CLOSER W/BACK CHECK NHO PRES SPECIFICATIONS ARE PART OF THIS SECTION. 3 H1104SD 335 PUSH/PULL 1"DIAM. TYPE SC IT CTC) 3 H710YB5N 3-0 BOTTOM RAIL WEATHERSTRIP 3 SD101 YB5N 10" BOTTOM RAIL UP TO 3' FURNISH AND INSTALL ALL STEEL DOORS AND FRAMES, COMPLETE 2 H4204 SO THUMBTURNS WITH. JAMB ANCHORS. STOCKLENGTHS QTY PART FINISH LENGTH DESCRIPTION MATERIALS 11 BE91503 YB5N 24-0 HEAD/JAMB/VERTICAL 3 BE91512 YB5N 24-0 SHALLOW POCKET FILLER 1. DOORS AND FRAMES BY PIONEER INDUSTRIES, INC., 2 BE91506 YB5N 24-0 HORIZONTAL STEELCRAFT, OR CECO. 2 BE91513 YB5N 24-0 4-1/2" SIDELITE BASE 4" E91015 YB5N 24-0 GLASS STOP DOOR FRAMES SHALL BE OF 16 GAUGE COLD ROLLED STEEL. 2 BE91510 YB5N 24-0 SILL FLASHING THEY SHALL BE MITERED AND WELDED AT CORNERS. FRAMES ACCESSORIES SHALL BE FURNISHED FACTORY- PRIMED AND SHALL HAVE CITY PART # LENGTH PKG DESCRIPTION THREE (3) "T" TYPE JAMB ANCHORS FOR EACH SIDE OF EACH 1 E20020 5OP/B SETTING BLOCK FRAME. CAULK AROUND ALL ABUTTING EDGES WITH CLEAR 1 E20047 50PIB WATER DEFLECTOR SILICONE. 1 E20154 50P/B 'MP' SIDE BLOCK FOR DEEP POCKET 1 EtO168 20P/B END DAM DOORS SHALL BE CONSTRUCTED OF TWO (2) SHEETS OF 18 2 e2002 60OIOOP/B #12 x 1-i14" PHSMS TYPE AS PIB GLAZING GASKET 2 E1 1220 t00GAUGE COLD ROLLED STEEL, WITH VERTICAL STIFFENERS NOT 1 1015 50P/B SHEAR BLOCK OVER 6"APART AND TOP AND BOTTOM EDGES REINFORCED 1 PC1028 100P/B #10 x 1-&4" PHSMS TYPE AS HORIZONTALLY BY STEEL CHANNELS, JOINTS AT EDGES OF DOOR SHALL BE CONTINUOUSLY WELDED. DOORS SHALL BE SOUND HARDWARE SET NO. 3: DEADENED BY FILLING CORE WITH MINERAL WOOL INSULATION. 1-1/2 PR. HINGES McKINNEY BEARING HINGES, 4-1/2- X 4-1/2" US28D THEY SHALL BE THOROUGHLY CLEANED OF GREASE AND OTHER 1 EA. LATCHSET W/LOCK SCHLAGE SATURN X US26D IMPURITIES, FILLED FLUSH, AND GIVEN TWO (2) COATS OF 1 EA FLOOR STOP BALDWIN #4000 FLOOR MOUNT BAKED -ON RUST RESISTANT METALLIC PRIMER. 1 EA KICKPLATE BURNS W X 30" X B" 16GA. US628 1 EA. COAT HOOK JACKNOB #400 WITH RUBBER BUMPER 2. SEE HARDWARE SCHEDULE FOR HARDWARE AND 1 EA. CLOSER LCN 1460 ALUMINUM CLOSER MANUFACTURERS. FOLLOWING ITEMS PROVIDED & INSTALLED BY G.C.: 1 EA. SIGN HANDICAP ACCESSIBILITY(ADA) DOOR & HARDWARE NOTES 1 EA. SIGN AS REDD: DOOR #5 "MEN" 7" X 2" DOOR #6 "WOMEN" 7" X 2" A. HARDWARE SUPPLIER TO VERIFY STATE/LOCAL HANDICAPPED: HARDWARE SET NO. 4: REQUIREMENTS FOR EXIT HARDWARE. 1-1/2 PR. HINGES McKINNEY BEARING HINGES, 4-1/2'B. COMPLETE SUBMITTALS ARE REQUIRED FOR APPROVAL PRIOR TO 1/2" X 4-112" US28D ANY ORDERING OR WORK. 1 EA. KICKPLATE BURNS 8" X 30" X 8" 16GA. U826D 1 EA. LATCHWx&' VI ET W/LVIEWING WIN SCHLAGE sATURN x us260 C. ALL DOOR HARDWARE MUST HAVE A SHAPE THAT IS EASY TO GRASP 1 EA. a"xe" VIEWING WINDOW 1 EA. CLOSER LCN 1460ALUMINUM CLOSER WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. D. IF PANIC HARDWARE IS REQUIRED BY CODE, G.C. TO FURNISH AND INCLUDE PRICE ON BID. FRAME TYPES ,,, NOTES: 1. DOOR AND FRAME SHALL BE FULLY ASSEMBLED AND ALL HARDWARE SHALL BE INSTALLED BY SKILLED CRAFTSMEN AT THE FACTORY AND THE UNIT DELIVERED TO THE JOBSITE READY FOR INSTALLATION. THE DOOR, HARDWARE AND THE HARDWARE INSTALLATION SHALL CARRY A MANUFACTURER'S 14-MONTH WARRANTY WI 24 HOUR SERVICE. (TOLL FREE NUMBER TO BE DISPLAYED ON DOOR) 2. H4101 FLUSH BOLT ON INACTIVE LEAF OF PAIR ONLY. E. SEAL BOTTOM OF WOOD DOORS. STOREFRONT NOTES: ALUMINUM STOREFRONT FRAME: BY YKK AP OF AMERICA. SYSTEM=YES 45 FS, 2"x 4 1/2" THERMAL SYSTEM FOR 1" INSULATED LOW "E" GLAZING. FLORIDA PRODUCT APPROVALM FL12926.R2 DOORS: YKKAP 20D FLORIDA PRODUCT APPROVAL M FL5851. R5 1/2" EXT. PLYWOOD SCREW AWNING CLIP THROUGH 1/2" PVC SLEEVE AND SEAL BRONZE ALUMINUM AWNING FRAMING CONT. EIFS STARTER W/�� DRIP EDGE SEALANT TO BACKER ROD (TYP.) WINDOW TYPES 16-8" R.O. 5'-4" 5'-4" 5'-4" 2Ar SIMILAR qr (MOUNT TO 13'4"AFF SEE SCHEDULE FOR DIMENSIONS) 1 3/4" In © QUIKSERV BP-7241E IP DRIVE-THRU WINDOW O NOA# 1&0316.02 FL-16711.R2 WINDOW SCHEDULE SIZE SERIES GLAZING FRAME REMARKS KEY WIDTH (R.O. HEIGHT (R.O.)MFR. MODEL TEMPERED DESCRIPTION PROFILE MATERIAL 16'-8" 6'-8" YKK AP YES 45 FS TEMP. 1" INSULATED LOW "E" 1-3/4" X 4-112" ALUM FL12926.R2 10'-8" 6'-8" YKK AP YES 45 FS TEMP. 1" INSULATED LOW "E" 1-3/4" X 4-1/2" ALUM FL12926.R2 6'-0" T-5" QUIKSERV BP-7241E IP TEMP. 1" INSULATED LOW "E" 2" X 4-1/2" ALUM FL16711.R2 1' 4" 2'-6" YKK AP YES 45 FS TEMP. V INSULATED LOW "E" 1-3/4" X 4-1/2" ALUM FL12926.R2 5'-4" 6'-8°YKKAP YES 45 FS TEMP. 1" INSULATED LOW "E" 1-3/4" X 4-1/2" ALUM FL12926.R2 O16'-8" 5'-4" YKK AP YES 45 FS TEMP. 1" INSULATED LOW "E" 1-3/4" X 4-1/2" ALUM FL12926.R2, BLACKOUT TINT/PAINT HEADER/BEAM - SEE STRUCTURAL DWGS. FOR SIZE AND LOCATION 1/4" SHIM ACOUST. CLG. TILE AND GRID WOOD TRIM. STAIN AND VARNISH TO MATCH CHAIR -RAIL SILICONE SEALANT STOREFRONT SYSTEM - INSTALLED PER MANUFACT. SPECIFICATIONS A 1 DOOR / WINDOW HEAD DETAIL VINYL WALL VVVCKINb CLEAR PLASTIC TYP. BEARING PACK STUD*T�'l FOR WINDOW HEADE1/2" EXT. PLYWOO1 1/4" RIGID INSULATIOH EMBEDDED OBASE COAFINISFS STARTER ANNG BEAD SYSTEM A 2DOOR/ WINDOW JAMB DETAIL Scale: 1-112'=T-0' EIFS MES CONT. EI CAST 1l2" GYPSUM B CONT. CAULKING CONTINUOUS FLASHING UNDER WINDOW CONT. CAULKINGCONTINUOUS FLASHINGUNDER WINDOW ACCENT BAND (PAINT] 1 1/4" RIGID INSULATION `*CONT. EIFS STARTER TRACKCONT. FLASHING, FILLED W/ - GROUT 15 lb. FELT MEMBRANE ON PLYWOOD BEHIND STONE SIMULATED STONE VENEER CORNER GUARD SILICONE CAULK SEALANT TO BACKER ROD 1/4" SHIM STOREFRONT SYSTEM,INSTALLED PER MANUF.SPECIFICATIONS SEALANT TO BACKER ROD (TYPICAL) Al A2 3WINDOW SILL / THRESHOLD DETAIL Scale: 1-1/2"=1' 0" STRUCTURAL- BEAM/HEADER. SEE STRUCTURAL DWGS SEALANT TO BACKERROD(TYP.) 2xSTUD DOORJAMB WOOD FRAMING 2x STUD 2xSTUD-DOORJAMB-WOOD FRAMING 2xSTUD SHIM AS REQ'D 20 GAUGE STAINLESS STEEL COVER (LENGTH OF WINDOW & EDGES SILL CAP BENT TO FIT CONT. SEALANT WOODTRIM SILICONE SEALANT 1/4" SHIM STOREFRONT SYSTEM- YKK YES-45-TU INSTALLED PER MANUF.SPECIFICATIONS EFTS SYSTEM SILICONE SEAL TO BACKER ROD YKK AP 20D DOOR SYSTEM SILICONE SEAL TO BACKER ROD WAINSCOTT PANEL AND WALL COVERING FINISHES CLEAR CORNER GUARD B 1/2" PLYWOOD SIMULATED STONE VENEER i L 15 LB. FELT MEMBRANE PLYWOOD jo SILICONE SEAL TO BACKER ROD E YKK AP 20D DOOR SYSTEM TROD SILICONE SEAL TO BACKER WAINSCOTT PANEL AND WALL COVERING FINISHES CLEAR CORNER GUARD B2 1/2" PLYWOOD CONT. CAULKING STAINLESS STEEL 20 GA. OVER WD. SHIM EXTEND UNDER WINDOW FRAME AND BEHIND ELECTRIC EYE 1" EA. WAY 2x12 WD. BLOCKING ELECTRIC EYE WIRE FEED FROM ELECTRIC EYE TO WINDOW MOTOR THRU SILL BATT INSULATION DOUBLE HEADER 1/2" PLYWOOD BLOCKING Ci SCHEDULED FLOORING, SEE ROOM FINISH SCHEDULE w0 0 ww 0 w< w& T i EIFS SYSTEMBLOCKING DOUBLE HEADER ZSILICONE TO BACKER ROD 1/2" PLYWOOD BLO( w-1-1/4" DRYWALL 0 PLASTIC SCREW 12" O.C. COMPONENTS #SB-1WBACKWRAPANDSEAL AT ALLOPENINGS < DO 0 0 w LnwO U)OOf wO- O O_0- EIFS SYSTEM w 1/2" PLYWOOD �J}< DOOR DOUBLE Sl O0ODOOR DOUBLE STUDS OU H 0w> wwJ/ncn wD xX w/nJ ALUMINUM THRESHOLD SET IN SEALANT REN 1EVWED Fur LIAt CODE GOMCpUt S-r. LUCIE BOCjCi m LL W lurnoa E z a N LL F- W = Z � Z Q W J � J m � J U W ZNJIl. V M rn N LU Q o LU N N N ^m it W > w O .3 OZ Q c� N N aJ N as tEt/_/�� r O U N<'nali U Z W 0 J Q m U3 w W J Q W U W ~ m C:) ti D' Q 1 w 0 w F 0 `14 .�- O CO ij r I popeYes Z W CK O __J Q U) U) w J rn z W Q0 � u U L CV w d i J o 7 L C C e G L I u U u u C U C L C L w 0 J C w Cw x C L_ �,�OF FLO,, - '. maR98913 . ti U c." 'sr ELL - III 3 F�-, RELEASE - DATE II I PROJECT NO. 2018-002 ISSUE DATE 12/21/18 DRAWN CHECKED C GM HDH SHEET NO. F l A17 BACKER TO FASTEN CABINETS TO WALL i o i N TOE -KICK CONNECTED TO CABINET DOOR TO ALLOW TRASH BIN TO SLIDE IN. FLOOR FINISH TO EXTEND INTO CABINET BASE M064- i N MIS COMPLETED ASSEMBLY R i N CORE -DRILLED WALL BASE BRACKET 911, 1 H-COUNTER PLACEMENT PARTIAL ENLARGED PLAN SCALE; 1/2" = P-0" NSCOT PANELING, CORNER TRIM -1) BASE (CB-1) e�� r CJ DIVIDER WALL AND MILLWORK SECTION 4 I DIVIDER WALL DIVIDER WALL ----- f...:. SPICE RACK: SCREW TO T/O G.C. TO SILICONE WALL WITH LAG SCREWS PROVIDED _ JARS IN PLACE 10'-0° BY FURNITURE SUPPLIER EQ 1, / / ,, EQ ACCENT COUNTER -TOPS AT TILE (M-2)7 - BOTH SIDES (SS-1) 8" ACCENT TILE (M-2) " 2'- WAINSCOT PANELING,* 10" 2'-6g" N W/CORNER TRIM _ b_ (WS-1) `r WAINSCOT PANELING TILE BASE (CB-1) W/CORNER TRIM (WS-1) TILE BASES ED F (CB-1) CODE COM PU LV BpCC ST • 2 DIVIDER WALL WITH SPICE JAR SCALE: 1/2" = P-0' > N V R m m N W M L f Cif 1 1 Lij ry !il aQNN Z M p c) U V L y LJJ L1J m W = z U CD � z Q w J � J m fN J U � � Np N O (� N Z U lO lL 684 W W d .> N Lu W Z D d N N Q N r C O U 0 w 0 ZD 0 O a w w w m O H H O z w x Lu w H L O z w x z cn w 0 cc w x 0 z a m z z w ni 0 0 w w T o p o 0 0 O H 0 H IQ w Lu a O J d Q Lu (n U) w � IJ —' O W / JL J Z w N LLI U 0 0 0- N w Z w r N a ¢ 00 Y t 2 ° J 9 O 0 O l%Ij�: � e'��" O• HUTT�, J U) Lu w w a. x w U) I C!) J Q f— Lu Q H uj C Lu ClIf Lli z U Z PROJECT NO. 2018-002 ..Jn.u.. _ ... .— '.1Ie135tkit1tMt1 ISSUE DATE 12/21/18 i DRAWN CHECKED G44 HDH SHEET NO. w Q()OCJt 0000 F\ 7 I; i C.) (;) 0 o i C"3 . n If v 3 3 I I a. 1 EQUIPMENT AND SEATING PLAN Scale: 1/4"=1'-0" i i a b a r:. WIEi� m oxw. t I � I 4 GENERAL NOTE: DRIVE THRU EQUIPMENT SHOWN FOR SCHEDULING PURPOSES ONLY. SEE CIVIL SET FOR ACTUAL EQUIPMENT LOCATION. .V N V N m Q) N OJ M OJ O) U M M M W � z a o � 'N W w I- W = Z Z Q W U o m � J Y U > m L z W c ) O M O -pJNe m z m v rn J�J W U 03 _ l > N h N M Z O N p = N Y CJ Z 6 w U O a w 0-1 m O O Z w Q w 2 F L U z w x Z U) w 0 w x F- 0 z U) z w � � => i\ U O / w' U) w O H U) Z W 2E Ir 0- '' ry p OOf I J a- Q L w (n C/) O Lu ` W J JL Q / Z ,:t U) U 0 Z c~i 0- w CN w Q O O a Y _ U)= o d Q W O U w w I..L 75 0 Z ^Q z w U) z F— Z w G J H r- w w IJu 01B w. HAROLD DANIEL NUTTER III x FL.REG. 98913 U) J RPI FGSF n6TF REVIEWED F1 CODE COMPLII ST. LUCIE COL BOCC PROJECT NO. 2018-002 ISSUE DATE 12i21/18 DRAWN CHECKED GPv1 HDH 4f r SHEET N . K1 QTY. TAG DESCRIPTION MANUFACTURER MODEL FURNISH/INSTALL ELECTRICAL WATER WASTE GAS REMARKS UJI m Z m l� Lj d �CD d Uj Ci _ C Z 114 tTj N A Fryer 1 A11.6 Fryer Battery, 6-20", Electric Ultrafryer Systems B-E20-20-6UCP (6) 56 (6) 20 1 /4 208 3 X 1 A31 Marinator - (reduced height) AryKing M101 5.0 115 1 X 1 A351 Sink, 1 Compartment, Left Hand Drain Board, 72" Kitchen Equip. Supplier Custom 0.50 0.50 1.50 0 A46 Portable Bread er/Blender/Sifter AryKing BBS-U-3515P 1.60 0.18 115 1 X 0.50 1 A48.1 Ice Cooled 3-Pan Batter Table (Left) Kitchen Equip. Supplier Custom 2.3 0.3 115 1 X 0.50 1 A48.2 Ice Cooled 3-Pan Batter Table (Right) Kitchen Equip. Supplier Custom 2.3 0.3 115 1 X 10.50 1 A54 Freezer, Upright Delfield GBF1P 12.0 1/2 115 1 Ix 0 1 A92 Grease Collection System Griffin Industries BOSS 10.0 1.2 115 1 Ix B Baking 1 B10 Oven, 1/2 Size, Double Deck Convection, Elec. Blodgett 2-CTB (2)24 (2)6 208 3 X 0 1 B60 Refrigerator, Upright Delfield GBR1P 112.0 1/3 115 1 X 0 1 B65 Biscuit Holding Unit (Option) Kitchen Equip. Supplier Custom 4.5 1.44 120 1 X 0 ` C Sandwich Refrigerator, Sandwich Unit Delfield 4427-6 6.5 1/5 1115 1 X 0 1 C10.27 1 C21 Toaster, Vertical Contact ROUND UP VCT-2 9210907 15 1.8 120 1 X 0 Wall Mounted Shelf, Holding Unit, Wrap Kitchen Equip. Supplier CUSTOM 0 Prep 1 C30.1 D 1 ID10.30 Work Table, w/ 4" backsplash w/ u/s Kitchen Equip. Supplier Custom 0 1 D10.36 Work Table, w/ 4" backsplash w/ u/s Kitchen Equip. Supplier Custom 0 1 D10.60 Work Table, w/ 4" backsplash w/ u/s Kitchen Equip. Supplier Custom 0 0 D11.30 Work Table, w/ 4" backsplash w/ u/s, open below Kitchen Equip. Supplier Custom 0 i` 1 D11.36 Work Table, w/ 4" backsplash w/o u/s Kitchen Equip. Supplier Custom 0 e 2 D20 Microwave Oven Amana HDC182 14.3 1.7 208 1 X 0 1 D22 Shelf, Microwave Oven Kitchen Equip. Supplier MOS-2126 Custom 1 D30 Packing Station w/Cup Dispenser & Dipper Well Kitchen Equip. Supplier CUSTOM 6.0 1.24 208 1 X 0.50 2.00 0 1 D40 Sink, 3 Compartment, 94" Long, 18" DB, R & L Universal Stainless 3N1824-21)18 0.50 0.50 2.00 0 2 D70 Dispenser, Hot Water w/Wall Bracket Bunn-O-Matic H5E ELEMENT SST 19.50 4.50 208 1 X 0.25 0 1 D81 Chubb Warmer, Elec. Rethermalizer Ultrafryer Systems REO-1620 47.6 9.5 208 1 X 0.25 1.50 0 1 D90 Holding Cabinet, Reach -In Winston HA-4522POP 17.6 2.11 120 1 X 0 2 D92 Side Items Holding Unit, Pass-Thru Prince Castle DHB-P1A 13.87 3.33 208 1 X 1 1 D93.1 D94 Dedicated Holding Bin Dedicated Holding Unit, 12 Pans(4x3H) Prince Castle Prince Castle DHB2PT-60P DHB3PT-41 26 23.7 6.9 5.7 208/240 1208 3 1 1 X 1 X Verify Utilities E Walk -In 1 1 E10.1 E10.2 Walk -In Cooler Walk -In Freezer Kolpak Kolpak Custom Custom APR 1818-3/65ED 208 208 3 3 X X 0 0 0 Verify Dimension & Utilities with K.E.S. Verify Dimension &Utilities with K.E.S. i 2 E20 Rack, Bus Pan Kelmax F Ventilation 1 IF15 1 F15.1 Exhaust Hood, Back Shelf, 6-20" Fryers Heated, Holding Unit, Wall mount Captive Aire Kitchen Equip. Supplier 2812 BLL Custom (PC-HPL52-26) 18.8 3.9 115 208 1 1 X X 0 0 2 Ex 3/4 HP 935 CFM each I; 1 F74 Batter Station Exhaust Hood Captive Aire 3024 VHB-G 115 1 X 0 _ 600CFM G Shelving 1 G10.60 Shelving, 4Tier, 24" Wide, 60" Long Intermetro Metroseal 0 ` u 1 G20.48 Shelving, 5Tier, 24" Wide, 48" Long _ Intermetro Metroseal 0 F 1 G20.54 Shelving, 5Tier, 24" Wide, 54"Long Intermetro Metroseal 0 1 G24.54 Shelving, 5Tier, 21" Wide, 54"Long Intermetro Metroseal 0 4 G20.60 Shelving, 5Tier, 24" Wide, 60" Long Intermetro Super Erecta 0 1 G20.72 Shelving, 5Tier, 24" Wide, 72" Long Intermetro Super Erecta 0 4 G30.36 Shelving, 2 Tier Wall Mounted, 36" Long Intermetro Erecta 0 C 3 G30.42 Shelving, 2 Tier Wall Mounted, 42" Long Intermetro Erecta 0 2 G30.48 Shelving, 2 Tier Wall Mounted, 48" Long Intermetro Erecta 0 1 G30.60 Shelving, 2 Tier Wall Mounted, 60" Long Intermetro Erecta 0 C 2 G40.30 Dunnage Rack, 24" Wide x 30" Long Kelmax Channel 0 4 G40.48 Dunnage Rack, 24" Wide x 48" Long Kelmax Channel 0 - 1 G40.60 Dunnage Rack, 24" Wide x 60" Long Kelmax Channel 0 1 G51.88 Drive-Thru Station, 30"x88" Kitchen Equip. Supplier Custom 0 0 G52.88F Drive-Thru Drink Station, Free Standing Drink Machine Kitchen Equip. Supplier Custom' 1 G54.54 Drive-Thru Table Kitchen Equip. Supplier Custom 2 G62.22 Shelving, 2 Tier, Undercounter mount, 18"x22" Intermetro Super Erecta 0 1 G62.36 Shelving, 2 Tier, Undercounter mount, 18"x36" Intermetro Super Erecta 0 H Production 1 IH10.3PD 1 IH83 Production Counter, Dual Line, 52 1/4" x 134" (Prince -Castle) Window -Wide open, Drive-Thru, Automatic Kitchen Equip. Supplier Quiksery Custom BP-7241E 114.0 15.0 3.5 1120 120/208 1 1 X X 0.50 1 12.00 0 0 Verify Dimension & Utilities with K.E.S. J Front Service R VIEWED 1 Jim Front Service Counter Seating Vendor Custom W-101 #12R12 SK-SR 0 CO S 1. E COMPI. LUCIE C BOCC 3 J20 Cash Controller NKL Industries 0 0 J31 Suspended Condi ent Holder Cambro 0 1 J40 I Refrigerator, --Undercounter Silver King 4.9 1/6 120 1 X 0 N � N m M QNi � (i% 76 N IJL W frnD (OD m � L a o c E UL W W w z z 'fz Q w J m C J U 2. LU W Z W V7 M rn W Z 0 LL O W U o N H M14 W r LU 7 N ^� y M O Z N O V Z aN N O Q Q N U LL. w z Z w U z LLI U) Lu J w 0 Lu popeves z w 0 J_ Q CJ) `W -� W Z LU Q0 N LU I O �- a J it J LL U W w a 0 HAROLD DANIEL HUTTER III FL. REG. 98913 PROJECT NO. 2018-002 ISSUE DATE 12/21 /18 CN LU J 0 Lij 2i a LU SNN CHECKED M Jc SHEET NO. K2.a