HomeMy WebLinkAboutPRODUCT APPROVAL STRUCTURAL COMPONENTY
1/9/2018
t
Building Code Online
Bay Home I Login 1 user Registration i
Product Approval Menu >
FL #
Application Type
Code Version
Application Status
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
SCANNED
13Y
Subml $r lgC feStaYs � f Publications I Fec staff ! BaFall,aP' � Links ! Search
Application List > Application Detail
FL9555-R4
Revision
2017
Approved
UNION CORRUGATING COMPANY
701 S. KING ST.
FAYETiEVILLE, NC 28301
(910) 483-0479 Ext256
jstleby@unioncorrugating.com
John Stleby
jstleby@unioncorrugating.com
Structural Components
Roof Deck
Compliance Method Evaluation Report from a Florida Registered Architect or a IJcensed Florida
I Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation Report
Florida License i
PE-62240
Quality Assurance Entity 1
Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date
09/07/2027
Validated By I
Yoosef Lavl, P.E.
d, Validation Checklist - Hardcopy Received
Certificate of Independence
FL9555 R4 COI CertlFlcateIndeoendence.od
Referenced Standard and Year (of Standard)
Standard
ASTM E1592
i
FM 4470
Equivalence of Product Standards
Certified By
Sections from the Code
I
i
I
Year
2005
2012
1/3
D
r =
1/9/2018 Florida Building Code Online
Product Approval Method I Method 1 Option D
Date Submitted
08/23/2017
Date Validated
08/28/2017
Date Pending FBC Approval
09/09/2017
Date Approved
12/12/2017
FL # Model, Number of Name Description
9555.1 5V Panel I 29 ga., 24" wide, through fastened panel over wood supports
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9555 R4 II EvaluationReoortC2172 l.0df
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-70.25 Evaluation Reports
Other: Uplift load of 70.25 psf @ support spacing of 24" o.c. FL9555 R4 AE EvaluationReDOrtC2172 I.odf
Created by Independent Third Party: Yes
9555.2
MasterRib Panel I
26 ga., 36" wide, through fastened panel over steel supports
of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL9555 R4 II EvaluationReaortC2172 2.odf
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-47.2
Evaluation Reports
Other: Uplift load of 47.2 psf @ support s I acing of 60" o.c.
FL9555 R4 AE EvaluationReoortC2172 2.odF
Created by Independent Third Party: Yes
9555.3 MasterRib Panel I 29 ga., 36" wide, through fastened panel over steel supports
Limits of Use I Installation Instructions
Approved for use in HVHZ: No FL9555 R4 II EvaluationReoortC2172 3-odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +27.1/-37.7 Evaluation Reports
Other: Design load of 27.1 & -37.7 psf at support spacing of FL9555 R4 AE EvaluationReDOrtC2172 3.odf
48" o.c. I Created by Independent Third Party: Yes
9555.4
MasterRlb Panell
29 ga., 36" wide, through fastened panel over wood supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9555 R4 II Eva luationReportC2172 4.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +27.1/-36.2
Evaluation Reports
Other: Design load of 27.1 & -36.2 psf a support spacing of
FL9555 R4 AE EvaluationReoortC2172 4,Ddf
48" o.c. I
Created by Independent Third Party: Yes
9555.5 MasterRib Panel 29 ga., 36" wide, through fastened panel over nom. 1" x 4"
wood supports
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9555 R4 II EvaluationReportC2172 5-odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-138.9 Evaluation Reports
Other: Uplift load of 138,9 psf @ support spacing of 24" o.c. FL9555 R4 AE EvaluationReoortC2172 5,odf l
Created by Independent Third Party: Yes
9555.6 PBR Panel Min. 26 ga., 36" wide, through fastened roof panel over open
steel supports
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9555 R4 II Eva luationReoortC2172 6.odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +96/-163 Evaluation Reports
Other: Design loads of 96 & -163 psf at support spacing of FL9555 R4 AE EvaluationReaortC2172 6,Ddf
20" o.c. I Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: SSD-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public recdrds. If you do not want your e-mail address released In response to a public -records request, do not send electronic
Lora/odor aoo dB = .asox?oaramwGEVXQwtDatvOROQk7A5REBEOaziUdl7ntuFlu2iC5s%3d 2/3
1/9/2018 1ilonda Building Code Online
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. Tb determine If you are a licensee under Chapter 455, F.S.,
please click hUL.
Product Approval Accepts:
�-i ® Ekcf -xs:
Credit Card
Safe
3/3
� [ I
EVALUATION REPORT OF
UNION CORRUGATING COMPANY
`29 GA. 5V PANEL'
OVER WOOD SUPPORTS
FLORIDA BUILDING CODE 6TI3 EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 9555.1-R4
STRUCTURAL COMPONENTS
ROOF DECK
Prepared For:
Union Corrugating Company
P. O. Box 229
Fayetteville, NC 28302
Telephone: (910) 483-0479
Fax: (910) 483-8897
Prepared By:
Bala So'ckalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 NJ Lansing Ave., Suite C
Tulsa, OK 74106
Te=(866)
e: (918) 492-5992
366-1543
This report consists of
Evaluation Report (3 Pages including cover)
Installation Details (1 Page)
i
i
i
i
Report No. C2172-1
Date: 8.20.2017
i
i
i
i
*�BA9aeaeoQe,�a
®� �GY,A L I1V (�°
N� 02240
olim
:LI®
LU
s
L O R \. • �(���
Q
Manufacturer:
Product Name:
Panel Description:
Materials:
Support Description:
Slope:
i
Union CorrugatiI g Company
5V Panel
1
24" wide cover Ige with (5)1/2" high ribs
FL 9555.1-R4
C2172-1
8.20.2017
Page 2 of 3
Minimum 29 ga., 80 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755).
Nom. 1" x 4" (min) lumber (Southern Yellow Pine Untreated)
(Must be designed by others)
1/2:12 or ereater in accordance with FBC 2017 Section 1507.4.2
Design Uplift Pressure: 70.25 psf @ fastener spacing of 24" o.c.
(Factor of Safety = 2) (3 or more spans)
Panel Attachment: #9-15 or #10-114 x 1-1/2" long wood screws with washer
At panel ends @ 12" o.c. across panel width
At intermediate @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance with ASTM E1592-01 `Test
Method for Structural Performance of Sheet Metal Roof and Siding
Systems by i�Jniform Static Air Pressure Difference' and FM 4470
Section 5.5 `Resistance to Foot Traffic'.
Test Equivalency: The test pro ledure in ASTM E1592-01 comply with test procedure
prescribed inIASTM E1592-05(2012).
The test procedure in FM 4470 (1992) comply with test procedure
prescribed inIFM 4470 (2012).
Code Compliance: The product (described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. Tha maximum support spacing listed herein shall not be
exceeded. The design uplift pressure for reduced support spacing may
be computed using rational analysis prepared by a Florida Professional
Engineer. This product is not approved for use in the High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation iReport. Refer to FBC 2017 Section 1505 and current
approved roofing materials directory for fire ratings of this product.
Q
Supporting Documents:
i
ASTM E1592 Tel st Report
Farabaugh Engineering and Testing Inc
Project No. T246-06, Revised Reporting Date 11/7/06
FM 4470 Test Report
ENCON Technology Inc
C1583-3, Reporting Date 7/24/08
FL 9555.1-R4
C2172-1
8.20.2017
Page 3 of 3
i � �
,� � � i �