HomeMy WebLinkAboutENGINEERING""GENERAL NOTES 1. DESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS: 1. THE 2017 FLORIDA BUILDING CODE, 6TH EDITION SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CHAPTER 23 WOOD. 2. ASCE 7-10. & SE17 3. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 4. AC1318 CONCRETE REFRENCE MANUAL. 5. PCI PRECAST & PRESTRESSED CONCRETE. 6. AA ASM 35 & AA ADM 1 WIND LOADS: 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION '& BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. SCREENED ROOF ENCLOSURE FBC 2017 CH. 20 TABLE 2002.4 CONCRETE & FOUNDATION DESIGN: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: A. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: I. PORTLAND CEMENT TYPE 1 - ASTM C 150 II. AGGREGATES - LARGE AGGREGATE 3/4" MAX. - ASTM C 33 III. AIR ENTRAINING +/- 1 % - ASTM C 260 IV. WATER REDUCING AGENT - ASTM C 494 V. CLEAN POTABLE WATER VI. OTHER ADMIXTURES NOT PERMITTED B. METAL ACCESSORIES SHALL CONFORM TO: I. REINFORCING BARS - ASTM A615, GRADE 60 II. WELDED WIRE FABRIC - ASTM A185 C. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. D. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD -PRACTICE; PART 1, 2, & 3 - - - -INCLUDING HOT WHEATHER RECOMMENDATIONS. E. MOIST CURE OR POLYETHYLENE CURING PERMITTED. F. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. G. CONCRETE SHALL E _ BE PLACED OVER A -POLYETHYLENE VAPOR- - BARRIER. 2. FOOTING SIZE: EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB (3000 PSI) IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 8"x8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. 3. WHEN APPLICABLE FOR ATTACHING NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS. 4. WHEN INSTALLING 4" CONCRETE SLAB -ADD ADJACENT TO EXISTING-DOWELL INTO EXISTING CONCRETE 48" O/C W/8" #5 REBARS- DRILL 3/4" HOLE 4" EMBEDMENT- EPDXY W/ NON -SHRINKING "SIMPSON EPDXY TIE" (OR EQUAL). 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHER WISE NOTED. ALUMINUM SPECIFICATIONS: 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE SPECIFIED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH #12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. 3. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. FASTNER SPECIFICATIONS: - 1. FASTNERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO -BE TAPCONS OR BETTER, INSTALLED TO MFG.) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, AND FASTENERS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1/4"X3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1 "X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1/4"X2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14X2-3/4". WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10X1-1/2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE VX2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS: 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM -AND HAVE- ---MAXIMUM-COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. QJCI C�W fay St Lucie Goofy, RECEIVED lUCIE COUNTY B ING DIVISION F1 I Perm �1/IE�(UWEROR C M Y P f1§ R• Fr U T 3E KEP7 ON JOB SITE Ok NV INSPECT L (S) W16L BE MAD� I 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND INSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. MISCELLANEOUS: - - _1- -SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. 6. ALL 2X4 & GREATER ARE TO BE SMB UNLESS OTHERWISE INDICATED. RESPONSIBILITIES: 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. LEGEND: (ALL MAY NOT APPLY) SCR = SCREEN KP = KICK PLATE PW = PICTURE WINDOW X = HORIZ. SLIDING WINDOW 0 = HORIZ. STATIONARY WINDOW DH = DOUBLE HUNG WINDOW SH= SINGLE HUNG WINDOW SIP = SOLID INSULATED PANEL CT = CABLE TIE SG = SUPER GUTTER CS = CLEAR SPAN KB = KNEE BRACE ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2"x2"0.044" 2 x 3: 2"x3"x0.044" 2 x 4: 2"x4"4.044" 2-x 5: 2"x5"x0.050" OPEN BACK SECTIONS 1 x 2: 1 "x2"x0.044" 1 x 3: 1 "x3"0.044" SNAP SECTIONS 2 x 2 SNAP: 2"x2"x0.050" 2 x 3 SNAP: 2"x3"x0.050" 2 x 4 SNAP: 2"x4"4.045" SELF MATING (SMB) 2 x 4 SMB: 2"x4"x0.044"x0.100" 2 x 5 SMB: 2"x5"x0.050"x0.100" 2 x 6 SMB: 2"x6"x0.050"x0.120" 2 x 7 SMB: 2"x7"4.057"0.120" 2 x 8 SMB: 2"x8"x0.072"x0.124" 2 x 9 SMB: 2"x9"x0.082"x0.124" 2 x 10 SMB: 2"x10"0.092"0.398" NOTE: AS INDICATED ABOVE ALL MEMBER PROFILES ARE INDICATED IN INCHES. I W LL ff J m � _I UI M Co z E _z _¢ Q O U U W -� 0 oo w < z -' � �.L N LLI M C: z20�� W Q Q = 0 Lo � IZ N 0 Co Ld a 00 o 0 o m N a � 0 00 w rn H m U)9 M 04 ti 0 oo O H W O W -1 J w W U�LL U) U) U) W Z�U w ~ UMQ w HCd DESIGN DATE: 04/19/2018 REVISION 1: 8/6/2018 PAGE: REVISION 2: DATE SCALE: NTS I N 00 r- 0 w U U FLASHING 0 `HORIZONTAL OR SLOPED ' 0 1"x2" FASTEN TO COL. (INTERNAL) to W/(2) #1 Oxl-1/2" SMS, FASTEN TO (2) #10x3" SMS INTO SCREW EAVE RAILS ABOVE W/#10X1-1/2" SMS BOSSES FOR EDGE MEMBER-,""",= LU 24" O.C. AND 6" FROM END.d I_ .. 00 °I ----------- TABLE D BEAM QTY EACH SIDE/SIZE 2x3 4/12 2 x 4 8110 2 x 5 8/10 2 x 6 10/10 2 x 7 12110 2 x 8 8114 2 x 9 9/14 2 x 10 9/14 L o r 0 1 ° o EDGE MEMBER o ALUMINUM INTERNAL OR EXTERNAL 1 1 3 ~ o OR PURLIN ° RECEIVING CHANNEL w/(4) #10x75" I U 00 o ° - ° INTO GIRT OR PURLIN & (2) #14x75" j I LLj l INTO BEAM OR UPRIGHT 0.062 ANGLE CLIPS MAYBE USED \ i F- �; i BEAM PER PLAN (2) #1Ox2" l U p NOTCHED TO RECEIVE INTO BEAM COLUMN WITHIN EDGE MEMBER -------------- - ---__________ OR PURLIN PURLIN MEMBER � SMS, (EACH SIDE) BEAM BRACE ------------- - i ------------- � 00 QTY PER TABLE D - 0.0625" 6063-T6 FLAT PLATE --------- I i M� W 00 M J I I I I NOTCH PROFILE MAY VARY I w/(8) #10x3l4" SMS, MIN. 1/2" INSTALL BRACE EDGE DISTANCE; PLATE MAYBE TO CORNER I I 1 SMS INTO TO PERMIT CORRECT #SMS ---- i ____ _ FASTENED INTERNALLY TO BRACE SCREW BOSSES co S REW PURLIN UPRIGHT, BEAM -SNAP, SELF MATING OR HOLLOW I 1 1 z Q E Lu U COLUMN PER PLANS MAINTAIN MIN, OF 5/8" SEPERATION i I I �_ Q U 'nr/ 0 FROM EDGE OF BEAM SMS O.C. � V ; J ' ' O 00 - LJ..1 DETAIL E - UPRIGHT TO BEAM 'J 0') LL 7 CONNECTION SCALE: NTS DETAIL "D" - ROOF BRACING CONNECTION DETAIL "C" - GIRT OR PURLIN TO BEAM v L � L_ a) DETAIL SCALE - NITS OR POST DETAIL SCALE:NITS W �" (y) a_ C� ~ ^ � G W Q � 00 SECONDARY ANGLE SCHEDULE Q SECONDARY ANGLE MIN. 118" THICK W/ (2) #12 SMS INTO UPRIGHT QTY. TAPCON/ SCREW 2X3 0 2X4 1/2 2X5 1/2 2X6 2/ 4 2X7 2/ 4 2X8 3/ 6 2X9 3/ 6 2X10 4/ 8 ALL MEMBERS PER PLAN `MEMBERS VARY PER PLAN 2 x2 xO63 - DIM. TO MATCH PURLIN SIZE RECEIVING CHANNEL (2) #12 SMS INTERNAL TO EAVE RAIL (3) #12 EACH SIDE INTO PURLIN PURLIN Q Q U _ ______------------------------------ ___ _ ----- - ------- --- OLo ct C4 ti -------------------- ---------------- ----------- TOP OF HEADER 0 INTERSECTING ° a O MEMBER w (2) 10 MS w/1'FASTEN II �1 � u PENETRATION INTO SCREW BOSS OF EAVE RAIL - SEE P ° L.L OO II II MEMBER-TYP. BOTH SIDES - - - - - 1�11 OPEN BACK - --- - - - - - _ - _ _ EXTRUSION UPRIGHT COLUMN EA. SIDE (TYP.) DOOR JAMB OLUMN VARIES SEE PAGE 2 _ _ _ _ _ _ -- - ---- - - - - ii— PER PLAN ii ii j Z 1/4" CONCRETE ANCHOR (TAPCON XL OR EQUAL) (2) #10x2" SMS THRU 1x2 INTO AT EACH ANGLE EA. SIDE W/ MIN. 2-1/4" EMBED. - — — - ii ii jj jl EAVE RAIL EACH SIDE OF COLUMN INTO FOOTING (--TYP.) NOTE: FOR 256AN6LARGER ________________________ _ __ i (� SEE SECONDARY ANGLE SCHEDULE. WHEN 2'MS EA. W/ (2) #12x3/4" i� W- FASTENING TO WOOD USE 1/4" GALV. LAG SCREW SMS EA. SIDE (TYP.) p - IN LIEU OF CONC. ANCHORS AND ENSURE ------------ --- -- - ----- - -- _I _ _ _ _ -- - - - - - - O PENETRATION MIN 2-1/4" INTO STRUCTURAL p p ---------- FRAMING BENEATH (TYP) 'M2" OPEN -BACK BASE PLATE I FASTEN HEADER w/(2) #10x3" O O (TYP. EA. SIDE) i _ _li INTO SCREW_ BOSS -OF -HEADER - it DETAIL "G" -SLOPED PURLIN CL CONNECTION SCALE: NTS _ _ _ _ _ _ _ _ ° - a - - - - - - - NOTE: IF PAVERS ARE ii ii ALTERNATE HEADER CONNECTION - - `9 PRESENT, CONCRETE a ° 3" MIN. COVER II II WHEN Z-BAR IS USED- FASTEN II II ANCHORS SHALL (TYP.) Z-BAR TO COLIHEADER AT EACH p PENETRATE INTO CORNER AND 18" O/C I FOOTING 2-1/4" MIN. 1-1/2"x 1/16" PLATE 2-1/2"MIN. SPACING (TYP-)(12) #12xl" SMS (TOP OR BOTTOM) MIN. 3000 PSI CONC. FTG/SLAB W/ 2 > a (TYP.) @ V SPACING 6x6 -10x10 W.W.M. OR FIBERMESH or p p (Typ,) SIDE VIEW u (� OLUMN VARIES SEE PAGE 2 ALTERNATE BASE PLATE CONNECTION 2"x2" EDGE BEAM II II ATTACH MEMBER TO BASE PLATE II II C) 2"x2"x1/8" ANGLE W/ (2) #12x3/4" it ii (INTERNAL) w/(2) #1 Ox22" SMS jj J W SMS EA. SIDE (TYP.) 1/4" CONCRETE ANCHOR (TAPCON XL OR EQUAL) VR\ \N z -1 AT EACH ANGLE EA. SIDE W/ MIN. 2-1/4" EMBEDMENT P SECONDARY ANGLE MIN. 1/8" INTO FOOTING (TYP.). WHEN FASTENING TO WOOD ii ii ATTACH BASE PLATE TO MEMBER ii ii (2) #104" SMS LWLI THICK W/ (2) #12 SMS INTO USE 1/4" GALV. LAG SCREW IN LIEU OF CONC. ANCHORS w!(2) #10x3" SMS INTO SCREW INTO SCREW BOSSES COLUMN EA. SIDE (TYP.) AND ENSURE PENETRATION MIN 2-1/4" INTO ii BOSS OF BASE PLATE p jj CONNECTING EDGE J } J STRUCTURAL FRAMING BENEATH (TYP.) \ BEAM TO PURLIN U u \\\ II u 1"�" FASTENED TO COLUMN (n I w/(2) #1 Oxl-1/2" SMS INTO cq x }• 1'M2" OPEN -BACK BASE PLATE --- ----- - - ---- I j SCREW BOSSES FOR SMB w (n Q> I OR SNAP COLUMN W Z > (� ANCHORED TO FTG W/ 1/4" CONC u ° a . SCREW (TAPCON XL OR EQUAL) W/ --- - ------ ___ _ 0 W p W ° MIN. 2-1/4" EMBED. CONC. SCREW O Q U c I I 1"x2" SNAP F Z U TO BE INSTALLED 6" MAX FROM H U — Q COLUMN AND SPACED AT 24" O.C. — co NOTCH COLUMN AS REQ'D. w I--- 6IL " MAX MAX. COLUMN PER PLAN Z 0 . .......... ....:::::. 1 O of 6x6 -10x010 W.W.M. OR FBE MESHSLAB / n U (TYT P.) ::: :: U Q- (T (TYP-) 1/4" TAPCON (RED HEAD MFG. OR EQUAL) WITHIN 6" OF FRONT VIEW COLUMN 1-1/2" PENETRATION INTO UNDERLYING FOOTING DESIGN DATE: 04/1912018 ALTERNATE DETAIL "G" SLOPED REVISION 1: 8/6/2018 PAGE: DETAIL "F" - DOOR JAMB & HEADER PURLIN CONNECTION SCALE: NITSUPRIGHT TO DECK CONNECTION FOR 2x3 OR LARGER CONNECTION SCALE: NTS REVISION 2: DATE SCALE: N.T.S. SCALE: NTS GIRT FASTENED INTERNALLY AT EACH END w/ #10x1.5" EACH SCREW GROOVE. FASTEN TO BEAM w/ 2x2x125 ANGLE (2) #12 SMS INTO BEAM & (2) #10x1-1/2" THRU ANGLE INTO GUTTER WHERE NO GIRT IS PRESENT, ATTACH ANGLE DIRECTLY TO GUTTER _ 2"x2"x1/8" ANGLE w/(2) #12 SMS EACH LEG FOR BEAMS ABOVE 2x8 INSTALL GUTTER BRACE AT MIDPOINT BETWEEN BEAMS & INCLUDE 2" GUTTER BRACE AT EACH BEAM LOCATION 0 BEAM (2) #142" WOOD 71 (2) #12 SMS SCREW 18" O.C. 0 0 CLOSE BOTTOM OF 0 0 BEAM WHEN TRIM MED 044 RECEIVING CHANNEL, FASTEN w/(2) #12 SMS EACH SIDE OF B #10 SMS WITH[ OF BEAM & 24" 2x2x1/8" AN( EA. SIDE OF w/(2) #12 SN EACH LEG E `FOR BEAM OVER 2x5 044 RECEIVING CHANNEL FASTEN TO STRUCTURAL GUTTER INTERNALLY w/(2) #12 SMS ALTERNATELY 2x2x1/8" ANGLE BELOW GIRT, (2) #14 SMS INTO BEAM & (2) #12 SMS INTO STRUCTURAL GUTTER SIDE VIEW TOP VIEW "ALT DETAIL"H" — SCALE: NTS NOTE F INSTALL FASTENERS ALONG PERIMETER OF GUSSET -BEAM JOINT 3/8" MIN, FROM EDGE. FASTENERS MAY BE STAGGERED TO INSURE PROPER QUANTITY PER TABLE B-1 FASTENER PATTERN MAY APPEAR DIFFERENT FROM ILLUSTRATION. MAINTAIN 1/2" SEPARATION BETWEEN FASTENERS. MAINTAIN 3/8" MIN, FASTENER SEPARATION FROM BEAM JOINT OR EDGE OF BEAM LAP FASTENERS MAY BE EVENLY SPACED AROUND EDGE OF GUSSET WITHIN 3/8" OF BEAM JOINT. FASTENERS MAY BE STAGGERED TO INSURE PROPER QUANTITY PER TABLE B-1 FASTEN GUTTER TO FASCIA w/ #14x2" WOOD SCREW 18" O.C. (2) #12 SMS (2) #14x2" WOOD SCREW FASCIA (2"x6" MIN. EXISTING) STRUCTURAL GUTTER ERNATELY SEE PAGE 5 5052-H32 GUSSET TABLE B-1 BEAM SIZE COL. TO BEAM OTY SMS/ SIDE OF COL. BEAM TO BEAM QTY SMS/ FACE/SIDE 2 x 4 (5) #12 (9) #12 2 x 5 (5) #12 (9) #12 2 x 6 (7) #12 (9) #12 2 x 7 (10) #12 (10) #12 2 x 8 (12) #12 (14) #12 2 x 9 (14) #14 (14) #14 2 x 10 (16) #14 1 (15) #14 DETAIL "K" GUSSET CONNECTION SCALE: NTS 050" GUTTER STIFFNER FASTEN TO FASIA w(2) #12x2" WOOD SCREW FASTEN TO GUTTER w(2) #12 SMS I;zl_ "ALTERNATELY SEE PAGE 5 __v — DETAIL "M" BEAM & PURLIN TO GUTTER CONNECTION SCALE: NTS 2x2x1/8" ANGLE w/(2) #12 SMS EA. LEG— WHEN BEAM & PURLIN HIT ON CORNER - FASTEN OUTSIDE OF BEAM & PURLIN w/ 1/8"x2'S2" ANGLE & (4) #12 SMS EACH LEG FASTEN INSIDE CORNER (BEAM TO PURLIN) w/ 1/8"x2'S2" ANGLE w/(2) #12 SMS INTO EA. MEMBER (BEAM & PURLIN) (2) #14 WOOD SCREWS (2) #12 SMS INTO FASCIA 18" O.C. \ GIRT, \ SMB 0 1/8"&'x4" STRAP (2) #12 SMS INTO BEAM (2) #12 SMS INTO GUTTER 1/8"x2"x4" STRAP GIRT (2) #12 SMS INTO BEAM (2) #12 SMS INTO GUTTER 2x2x1/8" ANGLE w/(2) #12 SMS EA. LEG \ SMB GIRT 0 SIDE VIEW - STRUCTURALGUTTER \ (2) GUTTER BRACES EACH w/(2) #12 SMS — INTO GUTTER &(2) #14 WOOD SCREWS INTO FASCIA GIRT FASCIA (2) #12 SMS (2) GUTTER BRACES EACH w/(2) #12 SMS INTO GUTTER & (2) #14 WOOD SCREWS INTO FASCIA 1/8"x2"x4" STRAP (2) #12 SMS INTO BEAM GIRT (2) #12 SMS INTO GUTTER STRUCTURAL GUTTER TOP VIEW DETAIL "L" CORNER CONNECTION SCALE: NTS (9) #10x2" % 1/8" PLATE ON 45° ANGLE OR 1/8")0x2" ANGLE w/(4) #12 SMS INTO EACH INTERSECTING MEMBER PERIMETE FRAMING DETAIL'S-2" CABLE CONNECTION AT CORNER SCALE: NTS IIII 4 - 1 i I J 00 J m rn r,I M _zzzp_ o U of 0U LLI 0 00 0)w < Lei_ Lo r Lu co c v I" W Q _j m (EBOLTFOR 4Q BLE TENSION G 1/8" STAINLESS STEEL BRAIDED CABLE F- U 0 L(�Lo 1/8" STAINLESS STEEL 3000 PSI CONC. 40° MIN. BRAIDED CABLE 6x6-10x10 60° MAX. WWM OR FIBERMESH 4" MIN. SLAB w/FOOTING 3/8" DIAx3" EMBED CONC. SCREW ANCHOR (TAPCON OR EQUAL) 3000 PSI CONC. 6x6 10x10 40° MII 40° MAX. WWM OR FIBERMESH 10 4" MIN. SLAB WFOOTING 1.5"x5.5" ALUM. STRAP w/(2) 1/4" DIA x 2-1/4" MASONRY ANCHOR (TAPCON OR EQUAL) DETAIL 1-1" CABLE CONNECTION AT FOUNDATION SCALE: NTS N 0 0 CD W a c 00 rl N C9 00 LLI J F- J W W U U- U) w U) Q I-- W oW °¢ W a Z U O D_ � H 0_ z O 0 la� O O. DESIGN DATE: 04/19/2018 REVISION 1: 8/6/2018 PAGE: 4 REVISION 2: DATE SCALE: NTS �m 3/16" 5052-1-132 GUSSET #14 SMS @ 1 1/4" O.C. 2" X PURLINS ATTACH TO BEAM WITH MIN (4) #10 X 1 1/2" SMS PLACE WASHER UNDER SCREW IN GUSSET CORNER o o 0 o o o o. 0 0 0 0 0 0 l 1 1/4" (TYPICAL) °o �p\CP \✓ 5 23�6"T • �y31 5 6 51a g NOTES: 1. GUSSET DIMENSION ARE MINIMUM (2) REQ'D (1) EA SIDE OF BEAM - MAYBE INTERNAL OR EXTERNAL 2. AS BEAM SIZE CHANGES, ADD OR SUBTRACT SCREWS TO MAINTAIN 1-1/4" C/C SPACING 3. GUSSET LENGTHS REMAIN CONSTANT WIDTHS CHANGE TO MATCH BEAM SIZE. 2"X2"X1/8" ANGLE X 4" LONG PROVIDE #14 X 1" INTO EACH MEMBER AS NDICATED BELOW PROVIDE INTERIOR ANGLE ABOVE AND BELOW CHAI RRAI L EXTERIOR PLATE `CORNER POST GUSSET PLATE PER E-SERIES PURLIN "ANGLE 1" INTO EACH DICATED BELOW CORNER POST —\!, 6„ 1" X 2" O.B. FASTENED TO CORNER POST W/ #12 X 1 1/2" SMS AT 6" FROM TOP & BOTTOM RAILS TYPICALLY @ 24" O.C. 1/8" X 2" X 2" EXTRUDE ANGLE 5052 H-32 ALLOY EA CORNER W/ (2) #14 X 2" SMS INTO POST & (1) 3/8" DIA CONCRETE SCREW ANCHOR INTO CONCRETE (2) #10 X 1 1/2" SMS THRU SCREW BOSSES z va M coNc CHOR FfSEDME SLAB/FOOTING NOTES: SEE PLAN 1. CONNECTION DETAIL AT EAVE RAIL SIMILAR SIDE VIEW CORNER K-BRACE DETAIL SCALE: N.T.S. SELF MATING BEAM (4) #14 X 3/4" SMS INTO POST 1" X 2" BASE PLATE CONTRACTOR TO INSTALL ANCHORED TO CONC W/ 1/4" (2) #14 X 2" SMS THRU BRACE CONCRETE SCREW ANCHOR (MIN. 1 1/4" EMBED) INTO BEAM THRU GUSSET 6" MAX EACH SIDE OF POST " PLATE AND 24" O.C. MAX 2" CORNER POST W/ 1" X 2" @ 'k--,r/BACKSIDE 3/8" X LENGTH AS REQUIRED FOR 2 1/4" EMBED CONCRETE SCREWANCHOR INTO CONCRETE DETAIL #2 FRONT VIEW CP-1 CORNER POST TO_CONCRE-T-E-DETAIL-- -- -- - - - - _ - EAVE RAIL _ 3" x 2�-CORNER POST---- - - — SCALE' NTS _ _ _ _ �c 0.050=MIN.; 6063-T6 AttOY" - - - --- PLATE DR STRONGER (ONE SIDE) 1" x 2" O.B. PATIO SECTION 3" x 3" x 0.050" MIN., 6063-T6 ALLOY PLATE DR STRONGER (ONE SIDE) WITH (3) - #12 x 3/4" S.M.S. EACH SIDE AS SHOWN (3/8" MIN. PLATE EDGE DISTANCE & C-C FASTENER SPACING) x2x0.0 DACE (TYP.) LATERAL "W'-BRACING CONNECTION DETAILS K-BRACE N O 0 LJ a c 00 .--I O � N a � C7 pp W 0) H co U N OD 0 W U U J m c) J (D co c) Z Z < p U U W�Oco� W Q U- L ,I✓ ~_ Ill (") ICT Z 2 WQJ"Ta) Or- � 5 Q i = �- U W 0 LL a (3) - #12 x 3/4" S.M.S., 6" x 5" x 0.050" COLUMN EACH SIDE AS SHOWN 6063-T6 ALLOY PLATE 1/2" MIN. PLATE EDGE K-BRACE ( (ONE SIDE) OR STRONGER DISTANCE & C-C BRACE (TYP.) U �' FASTENER SPACING) ~ K-BRACE x2x0.093 J W BRACE (TYP. w W -i 2 x 3 x 0.070 CHAIR RAIL I O O `. O w . -I ---' O O U) O O i O GIRT (CHAIR RAIL) w W Q F- K-BRACE --0 W W�U 0-® o Lu o p ; Z a Yoh p C> r Q 3/8" 0 CONCRETE ANCHOR (2 PLATES) 2 x 2 x 0.093 d ' H- FOUNDATION IN LIEU OF TYP. 1/4" 0 CONCRETE BRACE (TYP.) (11 TOTAL) -#12 x 3/4" p 0 0-1 SCREWS FOR CORNER COLUMN S.M.S. AS SHOWN (1/2" MIN. U D- PLATE EDGE DISTANCE & "K"-BRACING LATERAL "IC' -BRACING C-C FASTENER SPACING) DESIGN DATE: 04/19/2018 REVISION 1: 8/6/2018 PAGE: LATERAL CONNECTION DETAILS CONNECTION DETAILS REVISION 2: DATE 5 SCALE: NTS