Loading...
HomeMy WebLinkAboutGENERATORD D) 9 D i i s ANNED i GENE.RAC DU.m _ ...�6..I c i......... RECEIVED 'I MAY 21 2018 ST. Lucle cownty, Fern INCLUDES: } • True Power'"' Electrical Technology • Two Line LCD Multilingual Digital Evolution'" Controller (English/Spanish/ French/Portuguese) Models Models • Two Transfer Switch Options Available: ST.LftWbQI (4 p �, 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. BPLAN REVIElN LDG: See Page 4 for Details. , i • Electronic Governor GUARDIAN® SERIES Residential Standby Generators ittfng I Air -Cooled Gas Engine • System Status & Maintenance Interval LFaTE; r,iy e/ Indicators PLUMB: • Sound Attenuated Enclosure DATE: • Flexible Fuel Line Connector MEECH: • Direct -To -Dirt Composite Mounting Pads' • Natural Gas or LP Gas Operation • 5 Year Limited Warranty • Capability to be installed within 18" (457 mm) of a building* FEATURES t4 kU tk�,/ 9 0 Standby Power Rating 036-0, G007037-0 (Aluminum - Bisque) -16 kVV 60 Hz Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz 039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz 043-1, G007042-1 (Aluminumn - Bisque) - 22 kW 60 Hz O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are'at the heart of Generac's O success in providing the most reliable generators possible. Generac's G-Force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics land sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. O TEST CRITERIA: V PROTOTYPE TESTED %1 NEMA MG1.22 EVALUATION V SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY �P� �' GEiVERAC �� 4DUS QUI LISTED - Note: CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL certified in the USA only. 'Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1 %. SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. w GENERAC ,�{4�� *�* MobilM e PROMISE Wi Link �taM1fEP �' �'�RPP� ' • 8ultt In ine f/54 using tlomesf/C and romkln parts. ° I GENERAC` 16/20/22 kW l features and benefits � Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducingloil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction apd added durability provide long engine life. • Electronic ignition/spark advance These features comtiine to assure smootNquick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection iprevents catastrophic'engine damage due to low oil. • High temperature shutdown Prevents damage duelto overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. l Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • • NEMA 3R Remote mounting Can be installed inside oir outside for maximum flexibility. Mounts near your existing distribution panel for simple, low-cost installation. I Evolution" Controls illuminated buttons Selects the operating mode and easy, at -a -glance status indication in any condition. • Auto/Manual/Off provides • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather-resistantluser interface for programming and operations. • Utility voltage sensing Constantly monitors utiIitylvoltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery'oniy when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. Installation System li • 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration tvhen connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. • Integral sediment trap Prevents particles and moisture fr.om entering the fuel regulator and engine, prolonging engine life ' G E ICI E RAC° 16/20/22 kW specifications Generator' 0007035-0, G007036-0, 0007038-0, G007039-0 G007042-1, G007043-1 Model G007037-0 (16 kW) (20 kW) (22 kW) Rated:Makimum Cont(9uous"Powe[`Capac(ry-(LP) " " " °> ill 000 Wails" ." ` a 20,000 Watist;, v •22000 �- ` Rated Maximum Continuous Power Capacity (NG) I 16,000 Watts 18,000 Watts" 19,500 n "I 4 ° " Rated Maximum Continu uo s Load Current - 240 Volts (LP/NG) 66.6/66.6 83 3/75 91.6/81.3 Total Harmonic Dlstor0on -�r,'�`,Less ihan'5% � �Less than 5°k' -` - Less�than 59n' ° Main Line Circuit Breaker 70 Amp 100 Amp 100 Amp Number of Rotor Poles 2 2 2 Rated AC`Frequency. - - _. � � Power Factor (Rawer Factow—� - not inoludeU) 1.0 1.0 1.0 -- _.LUp -.. .0 12 Uolte,gGroup 26R 540 CCA Minimum brGraup 35AGM660 CCA Mlmmum " Unit Weight (lb/kg) 406/186 448/203 466/211 Olmenslon"s (L'x ,xH) in/mm� _. = � - 48 x25x29/1218 z=638 x 732 Sound output m d8(A) at 23 it (7 m) wdh generator operatingat normal lonormal ad�� 66 66 67 �Sound;odtpat m dl3(Aj at 23 it (Z;'m) with generator in,Dutet Test`'"`=tow-speed exercise mode" h 58 'sFµ � . 56 �`�� 'w';58 �" Exercise duration I 5 min 5 min 5 min Engine Type of Engine GENERAL G-Force 1000 Series Number of Cylindersa 2 Displacement _ 999 cc 999 cc 999 cc �CylinderdBloT�k ;,_ �` A.fRi num•w/ Cast Iron Sleeve = Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignition Syste� �'� Sc[d-state vu/.� &Igneto� Solid state w/Magneto.7Solid-stale,w/°Magneto Govemor System Electronic Electronic Electronic Compression Ratio � _��KK I . 9,5`-�9 51 '9�5'l-^ �- Starter - R 12 Vdc 12 Vdc 12 Vdc oil Capecity Including Fjller � �'° "�r�`APProx.1°.9 qVi 8 L, > '�Ap�rox.11 <9 qUt-8 L��prox. 719 q 1:8�L°�, Operating rpm 3,600 3,600 3,600 Fuel`Con ums pt on -� 3 Natural Gas fta/hr (ma/hr) z 1/2 Load' 218 (t3.t7j 204 (5.78) ' 228�(6 46) FulhLoad ) 309 (8,75) 301 (8.52)� 327,(9 26) Liquid Propane "a ft Vhr (gallhr), [I/hr1 1/2 Load �91 6 (2.52)19,531 ,� 86 (2 37) (8,..991 92 (2,53) [9.571 106.8 (2:94) 1.1 11] . 121 3.56) 113.481 142 (3.90)y(14�77J . Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges 3.5-7' water column (7-13 mm mercury) for natural gas,10-12' water column (19-22 mm mercury) for LP gas. For Btu content, multiply 10/hr x 2500 (LP) or fl3/hr x 1000 (NG). For Megajoule content, multiply ma/hr x 93.15 (LP) or ma/hr x 37.26 (NG) Controls i 2-Line Plain Text Multilingual LCD Display �rvr Simple user interface for ease of operation Mode BuitonsAu[o :,. =77777 _ Automatic Start on;Uhbty failure, 7 day>exerciser n i- "' Start with starter control, unit stays on. It utility fails, transfer to load lakes place. oil Ready to Run/Maintenance Messages Standard Engine Run Hours Indication Stenda�d: Programmable start delay between 2-1500 seconds Util ty Voltage LRsslE efurn to U(ilily Adjustable ,(Brownoul$elun Standard (programmable by dealer only) _�" Frdm 140-171 V11,90 218 V ° °- _ Future Set Capable Exerciser/Exercise Set Error Warning RurdAlamVMaintenance Logs - Standard 50 Evenly Eacti ;` Engine Star( Sequence Cyclic cranking 16 sec on 7 rest (90 sec maximum duration). a_ __ _�.__ -- ' Sfiarte�cannol re-engage until 5 sec alter en me;has slopped, °_ �_ Smart Battery Charger Standa ri ChargerEaulVMissgg-AC,Warnng �� ° _ Standard.' Low Batterv/Battery Problem Protection and Battery Condition Indication Standard "Sound levels are taken from the front of the generator. Sound levels taken from other sides of the utility power outage. No overload capability is available for this rating. (AII ratings in content, ambient temperature,altitude, engine power and condition, etc. Maximumpowerde be higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying emergency power for the duration 5514, IS03046 and DIN6271). ' Maximum kilovolt amps and current are subject to and limited by such factors as fuel Blu(megajoule scent [or each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent for each 6 °C (10 °F) above 16 IC (60 `` ). ' GENERAC® 16/20/22 kW switch options Limited Circuits Switch Features • 16 space, 24 circuit, breakers not included. • Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load,100% equipment rated, both, inductive and resistive. • 2-pole, 250 VAC contactors. 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive install. Dimensions Height Width Hi H2 W1 W2 Depth in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 2/0-#14 2/0-#1,4 Model G007036-0 (16kW) Current Rating (Amps) 100 Voltage; _Rating (VACj 120/240; iD Utility Voltage Monitor (Fixed)* -Pick-up 80% -Dropout 65% 4AAetumt�,o�_�Ubllty �� �„,,'3 �`approx;;t5see Exercises bi-weekly for 5 minutes*t Standard tUL�Liste --_e �`Staridard - TolalCircuilsAvailable 24 Tan em�6`reaker Capabilities ~: B tandems Circuit Breaker Protected Available RMS Symmetrical 10,000 Fault Current @ 250 Volts Service Rated Smart Switch Features Model', G007037-020 kW)/ • Includes Digital Power Management Technology standard (DPM). G!��O of P„„ol al •o Intelligently manages up to four air conditioner loads with no additional Current Rating (Amps) 200 hardware. Voitage;a$lmg(VACj"", • Up to four more large (240 VAC) loads can be managed when used in Utility Voltage Monitor (Fixed)* conjunction with Smart Management Modules (SMMs). -Pick-up Dropout 80% s5% • Electrically operated, mechanically -held contacts for fast, clean connections. mu Return �or �� � w ap �3 s, • Rated for all classes of load,100% equipment rated, both inductive and resis- 5 Exercises bi weekly for 5 minutes bi- eek Standard Standard tive. UL Listed°�� Standard • 2-pole, 250 VAC contactors. Enclosure Type NEMA UL 3R • Service equipment rated, dual coil design. Grrcd5 esker Prot ed w zz oQo� „_a : • Rated for both aluminum and copper conductors. Lug Range 250 MGM - #6 • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution Controller • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- Exercise can be set to weekly or monthly ing flexibility. Dimensions 200 Amps 120/240,1 e Open Transition Service Rated Height Width H1 H2 W1 W2 Depth in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 YYej.. g, DEPTH GENERAC 16/20/22 kW available accessories Model # Product Descrtptton The WI-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon it, ring the LP tank's fuel level is an important step in making sure your generator is ready to run during an G007005 0 Wi-Fi LP Fuel Level Monitor unexpected powerfailure. Status alerts are available through a free application to notify when your LP tank is in need of a refill. Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- G006463-4 Mobile Link" cess to an Internet connection from a PC or with any smart device. You will even be notified via a -mail or test message when a change in the generator's status occurs. Available in the U.S. only. Etiery standby generator requires a battery to start the system. Generac offers the recommended 26R wet G005819 0 26R Wet Cell Battery c II battery for use with all air-cooled standby product (excluding PowerPact@). I ThIe pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 0°F. G007101-0 ;Battery Pad Warmer (Not necessary for use with AGM -style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below 0°F. Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load G005621 0 Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G007027-0 - Bisque Fascia Base Wrap Kit sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting (Standard on 22 kW) hoes located in the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from G005703-0 - Bisque Paint Kit future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. G006873-0 Smart Management odule Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its M (50 Amps) pourer management capabilities. It provides additional power management flexibility not found in any other power management system. it dimensions & UPCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. LEFT'SIDE VIEW FRONT VIEW Model UPC G007035-0 696471070354 G007036-0 696471070361 G007037-0 696471070378 G007038-0 696471070385 G007039-0 696471070392 G007042-0 696471070422 G007043-0 696471070439 GENE RAC* Geneac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com Q2017 Gene is Power Systems, Inc. All rights reserve0. All specifications are subject to change without notice. Part No.100D0000194-F 5/3/17