HomeMy WebLinkAboutPROJECT INFORMATION1058-WO-1jog (800x800)
vas e,
SCANNED
By
aj Lucie County
22
16
SAS
10 11024)
NYSE
j748)
PAA
17 R4,S Yr-2017
.16
(176,;
Y
RECE ".PF 0
MAY 0 7
Permitting D-.partment
St. Lucie County, FL
34
APSE
12 18
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWED
-FOR COMP&IIANCE
REVIEWED BY
DATE
PLANS AND PERMIT
MUST BE KEPT ON J013-Oft
' ON WILL 09 NO 114SPE'C'TI 1AAnE
L) P 4A
U
http-1);;ww.p—asic.o'rg/imageSketchesf etchI111058 1110 14
COPY
I OR
SPECIFICATIONS
STANDARD
ODEUSIZEUBS�ii420
HEIGNI 48
43f
52
L .0CAPOTYIC!, � r 23.6
47.2
99.1
xWATER CAPACITY (LBS1239
474--1,000
OMINATARE
— —
Q LNOER DIAMETEi fiNl
14.7
24
30
t3 t ER� OLUME'[cu IRJW
6.6116
13,120
27,680
GO tAR DI,7�METEE{,(i l}
6.�
16
16
L�U I AR HEIGHT INk
..... ...... __.._... __.................................. -.... _......... -
5.1
6.9
6.9 —
TR(Nf3DIAMETER Iil
5
19
22
CGA-510 NO OPD
CGA-510 NO OPD
( CGA-510 NOOPD
(t DARD'SPECIi iCA1101+f�
DOT-4BW240
DOT-4BW240
......
DOT-4BW240
METRIC
oe
�i
00
H1x1 1tjiMM1'
1,219
----- 86.71 ------�----__
1092
_..------- 172
1,321
360 -------_.__-------
PG C P T',4�1Fs f ���'�'
f ` �
,.k...€. _
— �� --
VATERBCAPACbTYIKGI
108.4
215
450
NOMItJAL TARE WtIQhLT (Kti1
'�,� �•�-.• ems---- �'`�-,---__.._.___.—.__..._..-1-__......_...-----..._.....----._---_._..__.....__.____------------
GYt NpER D(A�iEE(MN1
30.8
373
64.4
610
122.9
---•-------_......__._.....__._._.._....._..._.._.-.......____.---
762
C L ND R 1OL�) `r
108.4'i
215
450
LOLLADIAMETfR;1MM�
165
406
406
---.�._... _...... .... - ...........
130
----------- __-------
175
----_._ _ .......__....__.... __................. _.
175
L'0 IGI�T�(MNIjih
FODT#jGEQIAt(TR(J7Mj
r - r s r
lALa s
368
CGA-510 NO OPD
483
CGA-510 NO OPD
559
CGA-510 NO OPD
S'€ANF?ARDsSPECl1=1GAT�0�t �� `
DOT-46W24D
DOT-4BW240 �
DOT-48W240
-
1 /8° COATED
CABLE W/ (2
CLAMPS TO AN,
(PULLED T
6X3"
.00K
ANCHOR
I •
i
I '
GENERAL NOTES:
1. HECI ��H1a�1 ALL HAVE AN ALLOWABLE PULL-OUT CAPACITY OF 400#. MCHORS SHALL BE INSTALLED. PER ANCHOR
MANUFA T(> C ►!ED LOAD CAPACITY. CAPACITY VARIES WITH SOIL TYPE. VERIFY ANCHOR CAPACITY WITH SOIL
TYPE ��• VIP
a. ILITIES PRIOR TO. ANCHOR INSTALLATION
��� '�aq.. ,,
9 ..
3 ��O.rATIO OF. TANK. E% E�O, ADJACENT. STRUCTURES AND FEATURES IS DEPENDENT UPON LOCAL CODES AND IS THE
#j#W161LTili6DF4IS. S y
-1$k TANK AS SHOWN RAIDESIGNED TO PREVENT FLOTATION, COLLAPSE, OR LATERAL MOVEMENT DURING THE BASE
hx00,��' EVENT.
SS` ,0jjND LOAD'. DESIGN CRITE�
��a P "ATE WS . ` GC pi N/A; C# = 0.6
' :'^ ',:.•. Wes*
0 COPYRIGHT 2017 FARLEY ENGINEERING, LLC
t
G LLU ,�AGE d TE: AMERIGAS I A2tiloa
ConsulLing Engineer V40.111 — C
8800 N. U.S: j1; Suite #2 , Sebastian, Florida 32958
(772) 589.2206 lox
Copyright 2014 National Fire Protection Association (NFPA). License( II h.—eement, for Individual use and download on December 4 2014 to AMERIGAS PROPANE for designated user JESSICA BOOTH. No other
reproduction or transmission in any form t -"did without writtenpermission of NFPA. For inquires or to r pod unauffiori;l contact licensing@nfpa.org.
I4 i )
nrnn �wrr�mr,nrr.rn �r�rwrn 'rn nr oe 58-91
Table 15.1(f) Pipe Sizing Between Fh7tStage and Table 15.1(g) Copper Tube Sizing Between Second -Stage
Second=Stage Regulators: Outside Diameter Copper Tubing, Regulator and Appliance: Outside Diameter Copper Tubing,
Type K i Type K
Gas: Undiluted Propane
Inlet Pressurle: 10.0 psi
Pressure Drop:. ,1.0 psi 11
Specific Gravity: 1.52 �1
Tubing
I
Length
3IA in.
rrr��� t t�llr:
SOH in.
in.
7�ai in.
(ft)
0.305
0.402
0.527
0.652
0.745
30
284
587
1193
2085
2959
40
243
`50?
1021 I
1785
25,32
50
216
445
905 I
1582
2244
60
195
403
820
1.433
2033
70
180
371
754 II
1319
1871
80
167
345
702 I
1227
1740
90
157
374
659 I
1151
1633
100
148
306
622
1087
1542
150
119
246
500
873
1239
200
102
210
428 I
747
1060
250
90
186
379
662
940
300
82
169
343
600
851
350
75
155
316
552
783
400
70
144
294 I
514
729
450
66
136
276 I
482
654
500
62
128
260
455
646
600
56
116
236
I 412
585
700
52
107
217
379
538
800
48
99
202
353
501
900
45
93
189
I 331
470,
1000
43
88
179
I 313
444
1500
34
71
144
1 251
356
2000
29
60
123
1 215
305�
Notes:
(1) Capacities are in 1000 Btu/lu•.
(2) To convert to capacities at a gauge pressur� of,5 psi setting Mtb
10 percent (0.5 psi) pressure drop, multiply values by 0.606. To con-
vert to capacities at a gauge pressure of 15 psi setting with 10 percent
(1.5 psi) pressure drop, multiply values by 1.380I
Gas: Undiluted Propane
Inlet Pressure: 11 in. w.c.
Pressure Drop: 0.5 in.
Specific Gravity: 1.52
Tubing.
l:eIIgtb
3�8 1a.
1/zR in.
in.
3�4 in.
7�s in.
(ft)
0.305
0.402
0.527
0.652
0.745
10
45
93
188
329
467
20
31
64
129
226
321 '
30
25
51
104
182
258
40
21
44
89
156
221
50
19
39
79
138
196
60
17
35
71
125
177
80
15
30
61
107
152
100
13
27
54
95
134
125
11
24
48
84
119
150
10
21
44
76
108
200
9
18
37
65
92
250
8
16
33
58
82
300.
7
15
30
52
74
350
1
14
28
48
- 68
400
6
13
26
45
63
Note: Capacities are in 1000 Btu/hr
2014 Edition rWW
Designed to reduce first stage pressure of 5 to 20 PSIG down to
burner pressure, normally 11" w.c. Ideal for medium commercial
installations, multiple cylinder installations and normal domestic
loads.
Features
• Large vent helps prevent blockage and has il' FNPT for vent
piping.
I
• With 15 PSIG inlet pressure, regulator is designed to not pass
more than 2 PSIG with the seat disc removed.
• Incorporates integral relief valves.
• Replaceable valve orifice and valve seat disc.
Straight line valve closure reduces wear on seat li disc.
• Unique bonnet vent profile minimizes vent freeze over when
properly installed.
• Large molded diaphragm is extra sensitive to pressure changes.
• Built in pressure tap has plugged 1/8" F.NPT outlet. Plug can be
removed with a 3/16" hex allen wrench.
I
• Select brown finish.
anatls5omat sig-
I
Mounts directly to house line piping. Eliminates need for union joints,
elbows, and mounting brackets. Quick and easy to install.
• Backmount design
Maximum flow based on 10 PSIG inlet and 9" w.c. delivery pressure.
Matteflaft
Body............................................................................. Die Cast Zinc
Bonnet.......................................................................... Die Cast Zinc
Nozzle Orifice............................................................... ......... Brass
Spring........................................................................................ Steel
Valve Seat Disc ........................................................ Resilient Rubber
Diaphragm ......................... Integrated Fabric and Synthetic Rubber
�L
LISTED
Or 9
n
c
CFWhr.
BTURtr.
LV4403BSedes
300 350 400 450 500
750,000 1,000,00D 1,250,000
A16 100 Rego Dr. P.O. BI x 247 Eton, NC 27244 USA www.regoproducts.com Phone (336) 449-7707 Fax (336) 449.6594
Application
Ideal for use as a first stage regulator on any domestic size ASME or
DOT container in propane gas installations requiring up to 1,500,000
BTU's per hour. The regulator is factory set to reduce container
pressure to an intermediate pressure of approximately 10 PSIG.
I
Features
• Compact design can be connected to a service Jalve using either
a POL adapter or a RegO.product pigtail.
• Large threaded %" RNPT bonnet vent can easily be piped -away
underground installations without the need of glue kits or extra
adapters:
• Non Adjustable
• Large flow orifice resists freeze ups due to water concentration in
LPG vapor.
• Design provides for good flow regulation at both high and low
container pressures.
• Built in relief valve and travel stop comply with NFPA 58 over
pressure requirements.
• Incorporates %a" F.NPT downstream pressure tap for an easy
inline check of the regulator's delivery pressure.
• Molded diaphragm provides an o-ring type seal between the body
and bonnet,
• Body and bonnet are assembled in the USA using the unique,
patented RegUlok seal system.
• Fully painted in brilliant red for complete corrosion protection.
• Mounting bracket available as an accessory: part number 2302-31.
I
Ordering Information
Materials
Body......... :.................................................................................... Zinc
Bonnet.......................................................................................... Zinc
Spring.......::.................................................................................. Steel
Seat Disc...:................................................................Resilient Rubber
Diaphragm ................•....•....•. Integrated Fabric and Synthetic Rubber
1
E■■■■E■
,.
__��_
Rohr. 100
2
400
500
600
50
a
C m 300 7
elU/hr. 250,000 600,0a0 750,000 1.000,000 1.250.000 1,600,000 1,750,000
FLOW PROPANE
Maximum flow based on Inlet pressure 20 PSIG higher than the regulato setting and delivery pressure 20% lower than the regulalor setting and delivery pressure 20 % lower than the setting.
/
A14
100 Rego Dr. P.O. Bix 247 Elon, NG 27244 USA www.regoproducts.com Phone (336) 449-7707 Fax (336) 449.6594 Q�QO
I