HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGRlOPIOA DHPARTMQNi OR
Business & Professional Regulation
DBPR HOrrE. ABOD7DBPi1 DBPR, DfVIBIO!l5 CANjACt CBPR
Florida
1 ' Product Approval
USER: Public User
Product Approval Menu > Productor Aoplication Search > Ayplication List> Application Detail
POFMCEOFTHE
FL #
FL17022-R7
SECRETARY
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
08/18/2017v. date reapply 08/21/17
Archived
D
Product Manufacturer
Extreme Metal Fabricators, LLC
Address/Phone/Email
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
fivalidation@yahoo.com
Authorized Signature Richard McKuhen
fivalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
rchard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
O Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
96 Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.pdf
Standard
Year
TAS 125
2003
UL1897
2012
UL 580
2006
Sections from the Code
I
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
Date Validated 08/25/2017
Date Pending FBC Approval 08/28/2017
Date Approved 10/10/2017
FL # I Model, Number or Name Description
17022.1 1 - "5V Crimp" (R6) 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdd
Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704
impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A Evaluation Reports
Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.aft
assembly in compliance with the installation method listed in Created by Independent Third Party: Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.2
2 - "5V Crimp" (116)
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel,
mechanically attached to 15/32" plywood or Wood Deck with
exposed fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other; Refer to evaluation report for conditions. Install the
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr. ddff
Created by Independent Third Party: Yes
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.3 3 - "1.5" Mechanical Seam" (115) 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with clips and fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure; +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with the
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
17022.4 4 - "1.5" Mechanical Seam" (115)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with the
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
17022.5
5 - „I in. Nail Strip" (R5)
Limits of Use
approved for use in HVHZ: No
Approved for use outside HVHZ; Yes
ImpactR�isthnt: No
Design pressure: +N/A/ -Table A
Installation Instructions
FL17022 R7 II FL 17022.3 1.5 MECHANICAL
seam 24oa ssr.2df
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022 3 1 5 MECHANICAL
am 24ga ssr. pd f
Created by Independent Third NO.' Yes
1.5" rib height 16" WIdB, 0.03Z" aluminum, standing s8,'"'
roof panel mechanically attaC#ed tg 15132" plywood or V
Decks and fastenem
Installation Instructions
AL 1MIN2 7 II FL 1 022.4 ME HA
Ilsr.p� I L E
Verified By: Locke Bowden, P.
E.Created by Independent Third Party: y
Evaluation ReportsYes
FL17 22 7 AE F 17 22 ALUMI
r MN M q I E
Created by Independent Third pa
_ rtY: Yes
1" rib height, 16" wide, 26 gauge steel, standin
panel mechanically attached to 15/32" g seam roof
with fasteners. plywood or wood ded
Installation Instructions
FL17 22 R7 II FL 17022, 1
Verified By; Locke Bowden, P.E. 49704
N�AILSTRIP ssr.pdf
Created by Independent Third Party: v.,
Evah,_.1n _ n__
Palm City, FL 34990
Compliant with Florida Building Code 2017 (611 ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec.1507.
See Fastener attachment specifications above
METHOD 2 METHOD 3 METHOD 4
-93.5 PSF -201 PSF -228 PSF
16" o.c. 8" O.C. 6" o.c.
22" o.c. 22" o.c. 12" o.c.
FASTENER SIZE #9 #20 #20 #10
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580-06 & 1897-041 Test Report CES893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 225-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY-UL 1897-04 is equivalent to teststandard UL 1897-12r,... _ *Design pressure margin ofsafety 2;1
Locke Bowden, P.E. does not have, not will acquire a financial in lr; aleSg q��fticturing or distributing products
under this evaluation. �.
Locke Bowden, P.E. is not owned, operated, or controlled by a& compan'0m3difaktures, or distributing products under this
report. ; • ,°
• 4'T
• / / 7
%.�,�, .... • •
1
FL17022.1 6V Crimp (26GA Steel), 24" Wide Roof Par, - Details
Limltat ons:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
r..............
15r3T or greater Plywood, or
Wood plank
24
318
Panel
Overlap
Nominal 12" Nominal 12"
O.C. O.C.
Fasten
19 x 1-1/2" Min. or #10 x 1-1/2" Min. per
-fable "A" Hex Washer Head Screw
Spaced 12" o.c. across the Panel Width
Refer to Table "A" for Spacing Along Panel
Length
Deck-15/32" or greater
Plywood, or
Wood plank