Loading...
HomeMy WebLinkAboutPRODUCT APPROVALFLORID DOPARTmr OF Business & Professional Regulation BCIS Home I Log In I User Registration I Hot Topics ubm arge I Stats & Facts I Florida a BY I '- Product Approval Sa t Lucie County 7 Y. --L Publications I FBC Staff I BCIS Site Map I Links I Search I USER: Public User Product Aoproval Menu > Product or Aoolication Search > Application List > Application Detail rCKfSECRETARY �� OFhGE OF THE ow FL# FL1654-R22 L Application Type Revision ST. LUCIE COUNTY BUILDING DIVISION Code Version 2017 REVIEWED FOR COMPLIANCE Application Status Approved REVIEW BY DATE Comments PLANS AND PER IT MUST BE KEPT ON JOB SITE OR NO INSPECTION(S) WILL BE MADE Archived 0 Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1378 Ext 242 alender@polyglass.com Authorized Signature Ariel Lender THESE PLANS AND ALL PROPOSED WORK alender@polyglass.com ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO Technical Representative Maury Alpert COMPLY WITH ALL APPLICABLE CODES, Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (912) 429-8610 MAlpert@polyglass.com Quality Assurance Representative Ariel Lender Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1230 ALender@ polyg lass -co m Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer D Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/06/2018 Validated By John W. Knezevich, PE Certificate of Independence Referenced Standard and Year (of Standard) CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OR RECORD FILE COPY 'A Validation Checklist - Hardcopy Received FL1654 R22 COI 2017 01 COI Nieminen.pdf Standard Year ASTM D6162 2008 ASTM D6163 2008 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2009 FM 4470 2012 FM 4474 2011 p UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 09/14/2017 09/15/2017 09/22/2017 12/12/2017 FL # Model, Number or Name Description 1654.1 Polyglass SBS and APP Modified SBS and APP modified bitumen roof systems Bitumen Roof Systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL1654 R22 II 2017 09 FINAL Al ER POLYGLASS MODBIT FL1654- R22.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this application Evaluation Reports relates to one particular assembly over concrete FL1654 R22 AE 2017 09 FINAL ER POLYGLASS MODBIT FL1654- R22.Rdf deck. Refer to the ER Appendix for other systems and deck types. 2.) Refer to ER, Section 5 for other Limits Created by Independent Third Party: Yes of Use. Back Plext Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Co right 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Card Sate �PTRRINITYJERD ( APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE -( Table Deck Application Type Description Page 1A Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 5 1B-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-9 1B-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10-11 1C Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 11 1D Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 12-13 1E Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 14-15 1F-1 Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 16-18 1F-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 19-21 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 22-24 2B Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 25-28 2C Steel or structural concrete New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 29-31 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 32-40 3B Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 40 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 41-42 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 43 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 44-46 5A CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 47 5B CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 48 5C CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 49 5D CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 49 5E CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 49 6A Gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 50-52 6B Gypsum Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 52 6C Gypsum Reroof (Tear -Off) or Recover C Mech. Attached insulation, Bonded Roof Cover 53 6D Gypsum Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 53 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 54-58 7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 58 The following notes apply to the systems outlined herein: 1 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. ' Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-inch penetration. ➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, Insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the CIA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. Exterior Research and Design, I.I.C. d/b/a Trinity(ERD Evaluation Report P9290.02.08-1120 for F1.1654-1122 Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017 Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems, (570) 384-1230 Appendix 1, Page 1 of 58 �ITRJNITYI ERD 15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. TABLE 1: POLYGLASS ROOF COVERS Reference Layer Material Application BP -AA Base Ply One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type II Hot Asphalt at 20-40 Ply One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI (Base and Ply sheets, Asphalt- Ibs/square Note: Asphalt -applied sheets or insulation shall not be applied to poly film surfaced membranes. Applied) Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex S6 Type II, Polyglass HT Base 650 PG350 at 1.5-2.0 Cap Ply Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex 56 Type II, Elastoflex S6 G, Elastoflex 56 G FR, Elastoshield TS-G, Elastashield SBS-CA1 gal/square TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex 56 Type II Polyplus 35 1.5-2.0 SBS-CA2 Cap Ply Elastoflex VG, Elastaflex VG FR, Elastoflex 56, Elastoflex 56 Type II, Elastoflex 56 G, Elastoflex 56 G FR, Elastoshield TS-G, Elastoshield at gal/square TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Base Ply or Ply One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex 56, Elastoflex SBS-AA 56 Type II, Polyglass HT Base 650 Hot Asphalt at 20-40 Cap Ply Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex 56 Type II, Elastoflex S6 G, Elastoflex 56 G FR, Elastashield TS-G, (SBS, Asphalt -Applied) Ibs/square Elastoshield TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Note: Asphalt -applied sheets or insulation shall not be applied to poly -film surfaced membranes. Base Ply or Ply 650 or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex S6, Elastoflex S6 Type II, Polyglass HT Base SBS-TA Torch -Applied Cap Ply Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex 56 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, (5135, Torch -Applied) Elastoshield TS-G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed) Base Ply One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR Cap Ply Elastoflex SA P, Elastoflex SA P FR, Pol reflect SBS-SA Self -Adhering Unless otherwise noted, permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein, (SBS, Self -Adhering) Note., Elastobase (poly/sand) or Elastobase ( oly/ of ). APP-CA1 Cap Ply Polyflex G FR PG350 at 1.5-2.0 gal/square APP-TA Base Ply or Ply One or more plies Polyglass APP Base, Polyflex, Polybond (APP, Torch -Applied) Cap Ply Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR M � Torch Applied 0 16. Any of the following FBC Approved coatings maybe applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. ➢ PG200 Non Flbered Roof Coating; ➢ PG300 Flbered Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating; D PG650 Fibered Aluminum Roof Coating; ➢ PG700 High Quality Elastomeric Roof Coating or KM Acryl 25; ➢ PG7000S (Quick Set) High Quality Elastomeric Roof Coating or KM Acryl 25-QS (for granule -surfaced APP or SB5 only); PG800 Asphalt Emulsion Roof Coating; D Polyplus 60 Premium Non-Fibered Aluminum Roof Coating; D Polyplus 65 Premium Flbered Aluminum Roof Coating; ➢ Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15; ➢ Polybrite 70QS (Quick Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-Q$ (for granule -surfaced APP or SBS only); ➢ Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating. Exterior Research and Design, LLC. d/b/a Trinityl ERD Evaluation Report P9290.02.08-R20 for FL1654-RZ2 Certificate of Authorization H9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017 Prepared by: Robert Nleminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix'1, Page 3 of 58 �l i rTRRINITYIERD TABLE 1F-2: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) (Psf) Type Fasten Attach Base Ply Cap "SELF -ADHERING BASE PLY: W-136 Min. 19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 12-inch o.c. in 4-Inch lap and 12-inch o.c. in two SBS-SA SBS-SA, APP-SA, SBS- _52.5" Inch plywood (poly -film top) or Trufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows TA, APP-TA W-137 Min. 19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 12-inch o.c. In 4-inch lap and 12-inch o.c. in two Polyflex SA Base APP-TA -52.5" Inch plywood (poly -film top) or Trufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows W-138 Min. 19/32- Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch c.c. in 4-Inch lap and 12-inch o.c. in two SBS-SA SBS-SA, APP-SA, SBS- _60.0" Inch plywood (poly -film top) (2), equally spaced, staggered center rows TA, APP-TA W-139 Min. 19/32- Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrlp #12 12-inch o.c. In 4-inch lap and 12-inch o.c. In two Polyflex SA Base APP-TA 60.0' inch plywood (poly -film top) (2), equally spaced, staggered center rows TABLE 1G: WOOD DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System Deck (Note 1) Primer Roof Cover (Note 15) MOP (psf) Joint Treatment Base Ply Ply Cap Ply No. W-141 Min. 15/32- (Optional) PG100 None Polyflex SA Base (Optional) APP-TA APP TA -90.0 inch plywood Min. 15/32- (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS W-142 inch plywood PG100 None SBS-SA TA, APP-TA TA, APP-TA 97 5 Min. 15/32- Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled into Elastoflex SA V Base or (Optional) SBS-SA, SBS- SBS-SA, APP-5A, SBS W-143 inch plywood (Optional) PG100 place to create continuous bond. Elastoflex SA V FR Base TA, APP-TA TA, APP-TA 97 5 W-144 Min. 15/32- WB-3000 None SBS-SA (Optional) SBS-SA, APP-SA, SBS- _105.0 Inch plywood TA, APP-TA W 145 Min. 15/32- (Optional) PG100 Plywood Joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled into Elastoflex SA V Plus or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS 135.0 Inch plywood place to create continuous band. Elastoflex SA V Plus FR TA, APP-TA TA, APP-TA W-146 Min. 15/32- (Optional) PG100 Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled into Polyflex SA Base (Optional) APP-TA APP-TA 135.0 inch plywood place to create continuous bond. Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report P9290.02.08-R20 for FL1654-R22 Certificate of Authorization #9503 67H EDITION (2017) FBC NON-HVH2 EVALUATION Revision 20: 09/12/2017 Prepared by: Robert Nleminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 21 of 58