HomeMy WebLinkAboutEVALUATION REPORTSCANNED BY EXTERIOR RESEARCH & DESIGN, I.I.C. St Lucie County Certificate of Authorization #9503 �N STREET, UNIT 13 ',J TRINITY 1 ERD 353 CHRISTIAO FORD, CT 06478 (203) 262-9245 EVALUATION REPO R R ECEIVED ICP Adhesives and Sei lants, Inc. Evaluation Report 02768.03.06-118 12505 NW 44th Street MAY ® 3 ? 18 FL6332-RB Coral Springs, FL 3306 Date of Issuance: 08/08/2008 (888) 774-1419 ST. Lucie County, Permitting Revision 8:10/12/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: ICP Adhesives Polyset® AH-160 LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Eva Iuatior Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 10/12/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products It evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity Involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. �TRINITYJERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roof Tile Adhesives Compliance Statement: ICP Adhesives Polyset® AH-160, as produced by ICP Adhesives and Sealants, Inc., has demonstrated compliance with the 6th Edition (2017) Florida Building Code through testing in accordance with the Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. . 2. STANDARDS: Sections Pro a Standard Year 1504.2.1.1 Overturning resistance SSTD 11 1997 3. REFERENCES: Kaibt Examination Reference Date ERD (TST 6049) Static Uplift—SSTD 11 P39740.02.12 02/20/2012 ERD (TST6049) Static Uplift—SSTD 11 P39740.11.13-R1 01/02/2015 ICC-ES (EVL2396) 2012 IBC Compliance ESR-1709 12/01/2016 Miami -Dade (CER 1592) HVHZ compliance 17-0322.03 04/27/2017 PRI (TST 5878) Static Uplift—SSTD 11 ECM-001-02-01 09/21/2001 PRI (TST 5878) Static Uplift—SSTD 11 PFI-006-02-01 05/09/2005 PRI (TST 5878) Static Uplift—SSTD 11. PFI-006-02-02 05/09/2005 PRI (TST 5878) Static Uplift—SSTD 11 PFI-007-02-01 10/11/2605 PRI (TST 5878) Static Uplift — SSTD 11 PFI-008-02-04 02/21/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFI-009-02-03 02/21/2006 PRI (TST 5878) Static Uplift—SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) Static Uplift—SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFPI-010-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFPI-011-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFPI-012-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFPI-013-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFPI-014-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 ECM-003-02-01 06/13/2008 PRI (TST 5878) Static Uplift—SSTD 11 ECM-004-02-01 06/13/2008 PRI (TST 5878) Static Uplift — SSTD 11 ECM-005-02-01 06/13/2008 PRI (TST 5878) Static Uplift—SSTD 11 ECM-006-02-01 06/13/2008 PRI (TST 5878) Static Uplift—SSTD 11 ECM-007-02-01 06/13/2008 PRI (TST 5878) Static Uplift —SSTD11 ECM-008-02-01 06/13/2009 UL LLC (QUA 9625) Quality Assurance Service Confirmation Exp. 06/05/2018 4. PRODUCT DESCRIPTION: 4.1 ICP Adhesives Polyset® AH-160 is a two -component expanding polyurethane roof tile adhesive that is mixed and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are available in refillable tanks or disposable cylinders (ICP Adhesives ProPacko 30 & 100). 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. Exterior Research and Design, LLC. Evaluation Report 02768.03.06-R8 Certijlcate ofAutharizatlon #9503 6'u EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset® AH-160; (888) 774-1419 Revision 8:10/12/2017 Page 2 of 9 5.3 Fire classification is not part of this evaluation. Refer to a current Roofing Materials Directory for fire ratings of this product and FBC 1505.2. 5.4 ICP Adhesives Polyset® AH-160 can be used with flat, low and high profile tiles or any rigid, discontinuous roof assembly having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction. 5.5 Minimum underlayment shall be per FRSA/TRI April 2012 (04-12) or having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction for use with ICP Adhesives Polyset® AH-160. 5.6 Field tiles, meeting the limitations of FBC 1609.5.3, using ICP Adhesives Polyset® AH-160 are limited to projects having an Aerodynamic Uplift Moment (Ma), determined in accordance with FBC 1609.5.3 or Tables 2A and 2B of FRSA/TRI April 2012 (04-12), not greater than the following Allowable Overturning. Moment values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 1: FIELD TILESJIN ICP ADHESIVES POLYSETO AH-166 ALLOWABLE OVERTURNING MOMENT PERFORMANCE DATA - 2TOIMARGIN OFSAFETVALREADYAPPUEDFOR INDEPENDENT (SINGLE ORCONTINUOUS PADDY) PLACEMENT " 4.To:1 MARGIN:OF SAFETYALREADY'APPLIED FOR INTERDEPENDENT (TWO PADDY) PLACEMENT Tile (FBC 1609.5.3) Adhesive Paddy Placement Allowable Overturning Type. Profile Moment (ft-lbf) Independent; Single Paddy, Medium (2x7-inch, -30 gram) 60 Clay Flat Independent; Single Paddy, Large (WO -inch, -45 gram) 112 Concrete Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch at tile overlap) 54 Independent; Single Paddy, Medium (2x7-inch, -30 gram) 39 Clay Low Independent; Single Paddy, Large (2x10-inch, -54 gram) 67 te Concrete Medium Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch at the overlap) 58 Clay High Independent; Single Paddy, Large (2x10-inch, -45 gram) 134 Independent; Single Paddy, Medium (2x7-inch, "30 gram) 65 Clay High Independent; Single Paddy, Large (2x10-inch, -63 gram) 109 Concrete Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-1nch at tile overlap) 40 Clay Barrel 2x10-inch x "35 gram for pans; 2 @ WO -Inch x -17 gram for cap 147 Concrete Barrel WO -inch x-35 gram for pans; 2 @ ix10-inch x-17 gram for cap 107 Clay Cap atop 2x Independent: Continuous Paddy (-34 gram/ft) 135 stringer Concrete Cap atop 2x Independent: Continuous Paddy ("' 34 gram/ft) 116 stringer ClayCap atop 2x Interdependent: 105 stringer Head: One (1) #10 x 2'/:" screw; Overlap: l x 6 inch (-10.5 gram) Concrete Cap atop 2x Interdependent: 76 stringer Head: One (1) #10 x 2%" screw; Overlap: 1 x 6 inch (-10.5 gram) 5.6.1 Data in Table 1 relates to installation over a '30/90' underlayment system, as detailed in the FRSA/TRI April 2022 (04-12). Alternate underlayment systems include those having a current Florida Statewide Product Approval and/or approved on a local -level by the Authority Having Jurisdiction specifically for use with ICP Adhesives Polyset® AH-160. 5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with ICP Adhesives Polyset® AH-160 shall be tested in accordance with SSTD 11 or Testing Application Standard TAS 101. For the interdependent two -paddy method, an additional 2-to-1 margin above that specified in SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the 'allowable overturning moment'. Exterior Research and Design, U.C. Evaluation Report 0276B.03.06-RB Certificate ofAuthorlration #9503 6m EDITION (2017) FBC NON-HVHZ EVALUATION FL6332 RS ICP Adhesives Polyset® AH-160; (888) 774-1419 Revision 8:10/12/2017 Page 3 of 9 V TRINA"jY I ERD 5.7 Hip and ridge tiles using ICP Adhesives Polyset® AH-160 are limited to projects having hip/ridge design pressure requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 2: HIP & RIDGE TILES IN ICP ADHESIVES POLYSET11 AH-160 ALLOWABLE UPLIFT RESISTANCE, PERFORMANCE DATA 2 TO I MARGIN OF SAFETYALREADYAPPLIED FOR INDEPENDENT (CONTINUOUS PADDY)'PLACEMENT 4 TO 1 MARGIN OF SAFETYALREADYAPPUED FOR INTERDEPENDENT PLACEMENT Allowable Tile Substrate Attachment Method Design Pressure (psf) Clay 2x PT ridge board Independent: Continuous Paddy (-34.gram/ft) 116 Concrete 2x PT ridge board Independent: Continuous'Paddy (134 gram/ft) 107 Clay 2x PT ridge board Interdependent: Head: One (1) #10 x 2%" screw; 90 Overlap: 1 x 6 inch (-10.5 gram) Concrete 2x PT ridge board Interdependent: Head: One (1) #10 x 2Y2" screw; 56 Overlap:1 x 6 inch (-10.5 gram) Clay or Hip & Ridge Channel Metal (FL5374): Independent: Continuous Paddy (-34 gram/ft) 169 Concrete galvanized only Clay or Trim LockTM (FL5374): aluminum, independent: Continuous Paddy (^34 gram/ft) 173 Concrete galvanized, Galvalume® or stainless steel Clay or Trim Lock"". Plus (FL5374): aluminum, Independent: Continuous Paddy (" 34 gram/ft) 178 Concrete galvanized, Galvalume® or stainless steel Clay Top Notch (FL8095) Independent: Continuous Paddy (^ 32 gram/ft) 125 Concrete Top Notch (FL8095) Independent: Continuous Paddy 32 gram/ft) 1.46 6. INSTALLATION: 6.1 ICP Adhesives Polyset® AH-160 and the the roof assembly shall be installed in accordance with FRSA/TRI April 2012 (04-12) and ICP Adhesives and Sealants, Inc. published installation instructions, subject to the limitations outlined in Section S. 6.2 Hip and ridge boards or hip/ridge metal shallbe installed in accordance with the FRSA/TRI April 2012 (04-12). Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval. 6.3 Installation shall be performed by applicators who hold a valid Qualified Applicator Card presented'by ICP Adhesives and Sealants, Inc. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Tomball, TX 9. QUALITY ASSURANCE ENTITY: UL, LLC. = QUA9625; (847) 664-3623; LeAnna.Gradecki@ul.com Exterior Research and Design, U.C. Evaluation Report 02768:03.06-R8 Certificate ofAuthorkatlon #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-RB ICP Adhesives Polyset® AH-160; (888) 774-1419 Revision 8:10/12/2017 Page 4 of 9 �TRINITYJERD 10. PADDY PLACEMENT DETAILS (FROM ICP ADHESIVES. AND SEALANTS, INC. PUBLISHED LITERATURE): 10.1 Independent, Medium Paddy: Underlayment A,° _ c �71h. yj`Ka 111: Batten's optional ° EaveCourse o r � 1101 n: ' Eave Flat/Low Profile Tile Hail'through plastic cement (Wh4n requlred) Paddy.(Ben"thTile) Underlayment 7 in. �In. Battens Optional Eave - Closure Eave Course � Fascia i Medium ProfileTile Nail through plastic c _ ,e (when required) Paddy (Beneath Tile) Underlayment 7 In.z in. Battensoptional4�; r' % V EaveCourse ` � Fascia Weephole tUin. �2in Eaveclosure tc7 / Drip edge High Profile Tile Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-118 [ertAcate oJAuthorizatlon #9503 dm EDITION (2017) FBC NON-HVH2 EVALUATION FL6332-RB ICP Adhesives Polyset® AH-160; (888) 774-1419 Revision 9:10/12/2017 Page 5 of 9 D.2 Independent, Large Paddy: Nailthrough.plasticcement Paddy(BefieathTile) (when required). Underlayment. Battens optional a Eave Course loin: ~` til'. i� Fascia n / EeveGosure__.. Flat/Low Pro rile Tile 4TRINITY (EtD Nall through, plastic cement (whenreg40ed) Underlavment �14 ;Srpip. \ 2m.wide Battensoptlonal ti^ w �L Medium. Profile rite Nailth rougkplastic cemen (wheft required) / Paddy (BeneathTile). Underlayment 10.in. x ;. 2 in.wide Battens: optional, Eave Course Fascia Wedphole TO ih. 2 in. Eave closure' Drip edge High ProfileTite (GeneathTilej 'L Eave Closure Fascia Exterior Research and Design, U.C. Evaluation Report 02768.03.06-R8 Certiticate ofAuthorization #9503 6'H EDITION 12017) FBC NON•HVHZ EVALUATION Fi6332 R8 ICP Adhesives Polyset® AH-160; (888) 774-1419 Revision 8: 20/12/2017 Page 6 of 9 A3 Interdependent, Two Paddy: Battens optional ° ° Paddy (under tile) Singlepaddy f on top oftile l 4x 4 in. Sin'glepaddy undertiliµ'� Single paddy � 7 on underlayment 2 x4 in. / \ 10:int Fascia Fiat/LoW.Proftte Tile Nalfthr L.... Battens ° optional o" v Single paddy on underlayment 4 x'4 in. (/ Single 2x4in; paddy on �\ topof;tile, Eave cou rse Nn'.'2/ Nail through plastic cement Single paddy under file .(when required) Paddy(between tiles) Battens Paddy (under tile) optional o Single pad `�Ir on topof t,--. High Profile Tile Medium Profile Tito undertile ,addy (between tiles) / Paddy (under tile) Weephole Eave closure Drip edge `— Eave closure Fascia Exterior Research and Design, LLC. Evaluation Report 02768.03.06-R8 Certificate ojAathorizatlon #9503 6t" EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset® AH-160; (988) 774-1419 Revision 8:10/12/2017 Page 7 of 9 10.4. Two Piece Barrel (Cap & Pan) Tile: 1) Place enough adhesive toachieve 65to70sq;In. Steep pitch applications' in contact with the pan tile. (when requited) 2) 7uugsldd down, Placa adhosivc .112 inm.Covcrs , to 4 inch-tn from outsido ed0o of covertilo. . Install cover tile. ensuie 20 to 26 sq, in. contact area on each aide of cover tile,, undeflayment (` rJ7 am. Sheathing Eaveclosure (matar shown) Weephole Fascia Board Remove top portion of the,ea.va.course cover tlle.Abut to second course of pan tiles.Ensure eave end,of pan and cover tiles are flush at eave line: Two Piece Barrel - High Profile Tile. 10.5 Hip and Ridge (independent placement): t_ A l,u,l MP, uuvFra amAcd above h1 sur4:voa bold sides of Ilh Wittig.- board or gahim�d imul,frnme: to pxvxide cteadmrbloclsre. -ro-,W2cli Wrcl, MeR, abead of7CPPohsftttA?3•ld0 ws be applied doxw W cEtr;zr of lite lery'tatge board or ff-*, ttized fr<+cna F11101 I \JI KINI'jY j ERD Exterior Research and Design, U.C. Evaluation Report 02768.03.06-118 Certificate ofAuthortzation #9503 6TM EDITION (2017) FBC NON-HVH2 EVALUATION FL6332-R8 ICP Adhesives Polyset® AH-160; (888) 774-1419 Revision 8:10/12/2017 Page 8 of 9 10.6 Hip and Ridge (interdependent placement): - END OF EVALUATION REPORT Exterior Research and Design, Ll.C. Evaluation Report 02768.03.06-118 Certfflcate ofAuthorizatlon #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL6332 R8 ICP Adhesives Polyset® AH-160; (888) 774-2419 Revision 8:10/12/2017 Page 9 of 9