Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING TILESbHolida Product Approval USER: Public User Product Approval Menu > Product or App Iwtlon Search > App ication List > Application Detail FL # MAY ® 3 2 713 FL7804-RI O J%A'L I Application pe Revision /2 (&'0-CX"0—& Code Versior ST. Lucie County, Permitting, 2017 ST. LUCIE COUNTY BUILDING DIVISION Applications a us Approved REVIEWED FOR COMPLIANC REVIE �Y� DATE . _ Comments PLANS AND PERMIT MUST BE K T ON JOB Archived 0 I SITE OR NO INSPECTIONS) WILL BE MADE Product Manufacturer Entegra Roof Tile, LLC Address/Phone/Email 1289 NE 9th Avenue Okeechobee, FL 34972 (602) 515-6933 thomas.jemmett@boral.com Authorized Signature Thomas Jemmett thomas.jemmett@boral.com Technical Representative Address/Phone/Email THESE PLANS AND ALL PROPOSED WORK Quality Assurance Representative ARE SUBJECT TO ANY CORRECTIONS Address/Phone/Email REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO Category Roofing COMPLY WITH ALL APPLICABLE CODES. Subcategory Roofing Tiles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer O Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 11/02/2018 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL7804_RID _COI 2016_01 COI Nieminen.odf Referenced Standard and Year (of Standard) Standard Year ASTM C1492 2003 FRSA/TRI April 2012 2012 SSTD 11 1997 TAS 100 1995 CONCEALED FASTENERS OR ATTACHMENTS TAS 101 1995 ARE THE RESPONSIBILITY OF THE TAS 102 1995 CONTRACTOR OR RECORD TAS 102(A) 1995 TAS 112 1995 Equivalence of Product Standards FILE COPY Certified By https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquovOjOHI°/a2bAMgsl79%2bkb9MWULRpAyR%2fQOg3lx7gHM6LOA%3d%3d 1/2 5/1/2018 Sections from the Code Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 10/17/2017 10/19/2017 10/22/2017 12/12/2017 FL # Model, Number or Name Description 7804.1 Entegra Concrete Roof Tiles (HVHZ Concrete Roof Tile jurisdictions) Limits of Use Approved for use in HVHZ: Yes Installation Instructions FL7804_R10_II_2017 10 FINAL ER_ENTEGRA L7F 804- R10 HVHZ.P- f Verified By: Robert Nieminen PE-59166 Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER Section 5 for Limits of Use. Refer to ER Evaluation Reports Section 6 for Installation. FL7804_RIO M_2017 SO_FINAL _ER ENTEGRA LF 7804- R10_HVHZ.Rdf Created by Independent Third Party: Yes 7804.2 Entegra Concrete Roof Tiles (non- Concrete Roof Tile HVHZ jurisdictions) Limits of Use Approved for use in HVHZ: No Installation Instructions FL7804_R10_II_2017 10 FINAL ER_ENTEGRA FL7804- R10 NON-HVHZ.pdf Verified By: Robert Nieminen PE-59166 Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER Section 5 for Limits of Use. Refer to ER Evaluation Reports Section 6 for Installation. FL7 04 R10_AE_ 02 17 10 FINAL_€R_ENTEGRA LF 7804_ RIO NON-HVHZ,pdf Created by Independent Third Party: Yes Back N . Contact Us :: 2601 Blair Stone Road, Tallahassee Fl- 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: PrivaGy Statement :: Accessibllity, Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M = ® eCiiecfi M ! `Credit Card' I Safe hfps://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDquovOjOHI%2bAMgsl79%2bkb9MWULRpAyR%2fQOg3lx7gHM6LOA%3d%3d 212 EXTERIOR RESEARCH & DESIGN, LLC. ( 'j'� Certificate of Authorization #9503 TRII VI 1 1 ` p 353 CHRISTIAN STREET, UNIT#13 ERD, OXFORD, CT 06478 (203) 262-9245 EVALUATION REPORT rowEntegra Roof Tile, LLC Evaluation Report E39310.11.11-1-R4 r' fp� TEA 1289 NE 9th Avenue FL7804-R10 R U O F T I' ,L E Okeechobee, FL 34972 Date of Issuance: 11/02/2011 (602Y515-6933 Revision 4:10/17/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code (HVHZ) sections noted herein. DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ jurisdictions) LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DC4 ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 10/17/2017. This does not serve as an electronically signed document. Signed, sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a- financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. \,.1 TRINITY I ERD ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Tiles Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1523.6.5.2 Physical Properties TAS 112 1995 1523.6.5.2 Wind Driven Rain TAS 100 1995 1523.6.5.2.2 Static Uplift Resistance TAS 101 1995 1523.6.5.2.3 Static Uplift Resistance TAS 102 1995 1523.6.5.2.3 Static Uplift Resistance TAS 102(A) 1995 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) TAS 101 P39740.02.12 02/21/2012 ATL (TST3782) Physical Properties RT0624.05-14 07/03/2014 ATL (TST3782) Physical Properties RT0624.04-14 07/07/2014 ATL (TST3782) Physical Properties RT1210.02-15 12/17/2015 ATL (TST3782) Physical Properties RT1210.03-15 12/17/2015 ATL (TST 3782) Physical Properties RT1103.01-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.02-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.03-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.04-15 11/07/2015 ATL (TST 3782) . Physical Properties RT1103.05-15 11/07/2015 Miami -Dade (CER1592) HVHZ Compliance 14-0416.12 11/27/2014 Miami -Dade (CER1592) HVHZ Compliance 15-0721.04 11/05/2015 Miami -Dade (CER1592) HVHZ Compliance 16-0112.06 02/25/2016 Miami -Dade (CER1592) HVHZ Compliance 16-0112.07 02/25/2016 Miami -Dade (CER1592) HVHZ Compliance 16-0112.08 02/25/2016 Tile Roof Institute TAS 100, TAS 101,102, 102(A) Membership Confirmation Current PRI (QUA9110) Quality Assurance Service Confirmation Exp. 11/02/2018 Exterior Research and Design, U.C. Evaluation Report E39330.11.11-1-R4 Certff7cate of Author7rattan #9503 6EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 2 of 8 4. PRODUCT DESCRIPTION: 4.1 J ,TAS-112, Type 3a I 16' 1-1/T4' I 10, Y f-- 16'=j 2' 10' Y I Bermuda Flat Q�TMITYIERD BERMUDA FLAT, PLANTATION FLAT and HORIZON FLAT y l�. /-1 T9%4" Horizon Flat Plantation Flat �I Exterior Research and Design,LLC. Evaluation Report E39310.11.11-1-R4 Certiftate ojAuthorlration #9503 6EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 3 of 8 i \1111T'R1Nrry ERD 4.2 TAS 112, Type la (interlocking, high -profile) BELLA HIGH 4.3 I TAS M Type 1b Holes �� 1 Estate "S" Bella High "S" profile) and HACIENDA Hacienda Galena Spanish "S" Regal Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-114 Certificate afAuthorizatlon #9503 67N EDITION 12017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 4 of 8 \I TRINIiYIERD S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements. 5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for fire rating of this product. 5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations. 5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in accordance with TAS 112, Appendix W. 5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment products shall hold current Florida Statewide Product Approval or Local Approval for use in tile roof assemblies in FBC HVHZ jurisdictions. 5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements. 5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of RAS 118, RAS 119 or RAS 120, as applicable. 6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in accordance with Roofing Application Standard RAS 127-11 using the data outlined herein. TABLE I: AERODYNAMIC MULTIPLIERS -a. (FT3) Tile Batten Application Direct -Deck Application Bermuda Flat 0.189 0.205 Plantation Flat 0.267 0.289 Horizon Flat 0.305 0.330 Bella High "S" 0.349 0.378 Estate "S" 0.267 0.28SAk Hacienda 0.267 0.289 Galena Spanish "S" N/A 0.235 Regal 0.287 0.311 TABLE 2: RESTORING MOMENT DUE TO GRAVITY- MG (FT-LBF) Roof Slope (0) Tile 2:12<0<3:12 3:12<9<4:12 4:12<0<5:12 5:125A<6:12 6:12<6<7:12 6>7:12 Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Bermuda Flat 5.22 6.43 5.17 6.37 5.09 6.27 4.98 6.15 4.86 6.00 4.72 5.83 Plantation Flat 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 Horizon 7.60 8.32 7.52 8.24 7.41 8.12 7.26 7.95 7.09 7.76 6.89 7.55 Bella High "S" 6.19 6.89 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33 5.50 6.13 Estate "S" 6.14 6.84 5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14 Hacienda 5.92 6.80 5.92 6.80 5.82 6.69 5.70 6.55 5.56 6.39 5.41 6.22 Galena Spanish "S" N/A 6.20 N/A 6.13 N/A 6.03 N/A 5.89 N/A 5.74 N/A 5.57 Regal 7.77 8.34 7.77 8.34 7.65 8.20 7.49 8.03 7.30 7.83 7.10 7.61 Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4 Certiftate ofAothar/zatlon N9503 6T" EDITION (2017) FBC HVHZ EVALUATION FL7804-R30 Entegra Roof Tiles Revision 4:10/17/2017 Page 5 of 8 >�TRINITYIERD TABLE 3A: ATTACHMENT RESISTANCE' EXPRESSED AS A MOMENT- MF (FT-LBF) MECHANICALLY ATTACHEMSYSTEMS Tile Fastener Direct -Deck (min.15/32" plywood) Direct -Deck (min.19/32" plywood) Battens Type # Size Shank Clip Nail One (1) 10d Smooth or Screw N/A 7.3 9.8 4.9 Nail Two (2) 10d Smooth or Screw N/A 14.0 18.8 7.4 Nail One (1) 10d Smooth or Screw Eave 19.0 19.0 22.1 Nail One (1) 10d Smooth or Screw Field 24.3 24.3 24.2 Bermuda Fiat, Nail Two (2) 10d Smooth or Screw Eave 31.9 31.9 32.2 Plantation Flat or Nail Two (2) 10d Smooth or Screw Field 35.5 35.5 34.8 Horizon Nail Two (2) 10d Ring N/A 30.9 38.1 17.2 Nail' Two (2) 1 10d' Ring' N/A 50Y 65.51 48.31 Screw One (1) #8 N/A N/A 30.8 30.8 18.2 Screw Two (2) #8 N/A N/A 51.7 51.7 24.4 ' Installation with a 4-inch the headlap and fasteners located min. 2h-inch from head of tile. Nail One 10d Smooth or Screw N/A 8.82 11.81 4.12 Nail Two (2) 30d Smooth or Screw N/A 16.4 21.9 7.1 Nail One 10d Smooth or Screw Eave 19.02 19.0, 22.1' Nail One lod Smooth or Screw Field 24.3' 24.32 24.22 Nail Two (2) 10d Smooth or Screw Eave 31.9 31.9 32.2 "S" Nail Two (2) 10d Smooth or Screw Field 35.5 35.5 34.8 Estate or Hacienda Nail Two (2) 10d Ring N/A 27.8 37.4 28.8 Nail' Two 10d' Ring' N/A 43.01 67.51 50.91 Screw One #8 N/A N/A 25.82 25.82 22.92 Screw Two (2) #8 N/A N/A 47.1 47.1 49.1 Installation with a 4-inch tie headiap and fasteners located min. 2X-inch from head of tile. 2 For one (1) fastener installations, utilize hole that is approximately 4'/e-inch from the interlocking edge. Nail One (1) 10d Smooth or Screw N/A 5.1 6.8 2.8 Nail Two (2) 10d Smooth or Screw N/A 6.9 9.2 7.3 Nail One (1) 10d Smooth or Screw Field 23.1 23.1 19.0 Nail One (1) 10d Smooth or Screw Eave 29.3 29.3 24.0 Nail Two (2) lod Smooth or Screw Field 27.6 27.6 38.6 Bella High "r Regal Galena o Spanish "5" or Nail Two (2) 10d Smooth or Screw Eave 38.1 38.1 41.8 Nail Two (2) 30d Ring N/A 28.6 41.2 19.4 Nail' Two (2)1 10d' Ring' N/A 33.1' 48.1' 50.91 Screw One (1) 1 #8 N/A N/A 20.7 20.7 18.1 Screw Two (2) #8 N/A N/A 43.2 43.2 29.8 Installation with a 4-�Inch tile headlap and fasteners located min. 2Y.-inch from head of tile. Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4 Certificate of Authorization #9503 6TM EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 6 of 8 rTRINITYI'ERD TABLE 4: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT- MF (FT-LBF), 'MORTAR AND ADHESIVE -SET SYSTEMS ' Note from Entegra Roof Tile, LLC.: The performance data listed in Table 4 are based on the respective adhesive manufacturers' test reports and Miami-Dade,NOAs. Entegra Roof Tile, LLC. relies upon the adhesive manufacturers to provide these values for our inclusion in `this FBC ;HVHZ Evaluation Report. Please•'consult the individual adhesive manufacturer for information on product approvals, limitations, revisions or other information for determining wind load and overturning moment performance. Tile Adhesive Tile Product Product Approval Placement Mf (ft-lbf) "TILE BONDTM" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 41 Bermuda "Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 73 Flat, "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 52 Plantation Flat or Horizon Polyset® AH-160 by ICP Adhesives & Sealants NOA 17-0322.03 Interdependent (2-paddy) 43 paddy, Independentmedium p y , — 30 g) ( 51 Independent (large paddy, —45 g) 92 "TILE BONDTM" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 44 "Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 42 "S" "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 44 Estate or Hacienda "Polyset® AH-160" by ICP Adhesives & Sealants NOA 17-0322.03 Interdependent (2-paddy) 50 Independent (medium paddy, ^30 g) 37 Independent (large paddy, —54 g) 61 Mortar Various Per RAS 120 21 "TILE BOND'""" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 48 '?ouch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 52 Bella High "S", "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 36 Galena Spanish "S" or Regal "Polyset® AH-160" by ICP Adhesives & Sealants NOA 17-0322.03 Interdependent (2-paddy) 30 Independent (medium paddy, "30 g) 49 Independent (large paddy, —63 g) 94 Mortar Various Per RAS 120 25 7. LABELING: 7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. and/or ENTEIRIRR�'� Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S" Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R4 Certi7cate of Authorization JM503 6'" EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 7 of 8 Y• �,)TRINITYJERD and/or ns.on Labeling: Horizon Flat, Hacienda, Regal 8. BUILDING PERMIT REQUIREMENTS: As requirgd by the Building Official or Authority Havl'ng Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Plant Profiles Okeechobee, FL Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S" Ft. Myers, FL Horizon Flat, Hacienda Deerfield Beach, FL Horizon Flat, Hacienda, Regal 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777 - END OF EVALUATION REPORT — Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4 certiftate ofAuthorizallon #9503 6EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 8 of 8