HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING TILESbHolida
Product Approval
USER: Public User
Product Approval Menu > Product or App Iwtlon Search > App ication List > Application Detail
FL # MAY ® 3 2 713 FL7804-RI O J%A'L I
Application pe Revision /2 (&'0-CX"0—&
Code Versior ST. Lucie County, Permitting, 2017 ST. LUCIE COUNTY BUILDING DIVISION
Applications a us Approved REVIEWED FOR COMPLIANC
REVIE �Y�
DATE . _
Comments PLANS AND PERMIT MUST BE K T ON JOB
Archived 0 I SITE OR NO INSPECTIONS) WILL BE MADE
Product Manufacturer Entegra Roof Tile, LLC
Address/Phone/Email 1289 NE 9th Avenue
Okeechobee, FL 34972
(602) 515-6933
thomas.jemmett@boral.com
Authorized Signature Thomas Jemmett
thomas.jemmett@boral.com
Technical Representative
Address/Phone/Email
THESE PLANS AND ALL PROPOSED WORK
Quality Assurance Representative
ARE SUBJECT TO ANY CORRECTIONS
Address/Phone/Email
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
Category
Roofing COMPLY WITH ALL APPLICABLE CODES.
Subcategory
Roofing Tiles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
O Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 11/02/2018
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL7804_RID _COI 2016_01 COI Nieminen.odf
Referenced Standard and Year (of Standard)
Standard
Year
ASTM C1492
2003
FRSA/TRI April 2012
2012
SSTD 11
1997
TAS 100
1995
CONCEALED FASTENERS OR ATTACHMENTS
TAS 101
1995
ARE THE RESPONSIBILITY OF THE
TAS 102
1995
CONTRACTOR OR RECORD
TAS 102(A)
1995
TAS 112
1995
Equivalence of Product Standards FILE COPY
Certified By
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquovOjOHI°/a2bAMgsl79%2bkb9MWULRpAyR%2fQOg3lx7gHM6LOA%3d%3d 1/2
5/1/2018
Sections from the Code
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
10/17/2017
10/19/2017
10/22/2017
12/12/2017
FL #
Model, Number or Name
Description
7804.1
Entegra Concrete Roof Tiles (HVHZ
Concrete Roof Tile
jurisdictions)
Limits of Use
Approved for use in HVHZ: Yes
Installation Instructions
FL7804_R10_II_2017 10 FINAL ER_ENTEGRA L7F 804-
R10 HVHZ.P- f
Verified By: Robert Nieminen PE-59166
Approved for use outside HVHZ: No
Impact Resistant: N/A
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use. Refer to ER
Evaluation Reports
Section 6 for Installation.
FL7804_RIO M_2017 SO_FINAL _ER ENTEGRA LF 7804-
R10_HVHZ.Rdf
Created by Independent Third Party: Yes
7804.2
Entegra Concrete Roof Tiles (non-
Concrete Roof Tile
HVHZ jurisdictions)
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL7804_R10_II_2017 10 FINAL ER_ENTEGRA FL7804-
R10 NON-HVHZ.pdf
Verified By: Robert Nieminen PE-59166
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use. Refer to ER
Evaluation Reports
Section 6 for Installation.
FL7 04 R10_AE_ 02 17 10 FINAL_€R_ENTEGRA LF 7804_
RIO NON-HVHZ,pdf
Created by Independent Third Party: Yes
Back N
. Contact Us :: 2601 Blair Stone Road, Tallahassee Fl- 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: PrivaGy Statement :: Accessibllity, Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
M = ® eCiiecfi M
! `Credit Card' I
Safe
hfps://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDquovOjOHI%2bAMgsl79%2bkb9MWULRpAyR%2fQOg3lx7gHM6LOA%3d%3d 212
EXTERIOR RESEARCH & DESIGN, LLC.
( 'j'� Certificate of Authorization #9503
TRII VI 1 1 ` p 353 CHRISTIAN STREET, UNIT#13
ERD, OXFORD, CT 06478
(203) 262-9245
EVALUATION REPORT
rowEntegra Roof Tile, LLC Evaluation Report E39310.11.11-1-R4
r' fp� TEA 1289 NE 9th Avenue FL7804-R10
R U O F T I' ,L E Okeechobee, FL 34972 Date of Issuance: 11/02/2011
(602Y515-6933 Revision 4:10/17/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
(HVHZ) sections noted herein.
DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ jurisdictions)
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DC4 ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 10/17/2017. This does not serve as an electronically signed
document. Signed, sealed hardcoples have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a- financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
\,.1 TRINITY I ERD
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section
Property
Standard
Year
1523.6.5.2
Physical Properties
TAS 112
1995
1523.6.5.2
Wind Driven Rain
TAS 100
1995
1523.6.5.2.2
Static Uplift Resistance
TAS 101
1995
1523.6.5.2.3
Static Uplift Resistance
TAS 102
1995
1523.6.5.2.3
Static Uplift Resistance
TAS 102(A)
1995
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
TAS 101
P39740.02.12
02/21/2012
ATL (TST3782)
Physical Properties
RT0624.05-14
07/03/2014
ATL (TST3782)
Physical Properties
RT0624.04-14
07/07/2014
ATL (TST3782)
Physical Properties
RT1210.02-15
12/17/2015
ATL (TST3782)
Physical Properties
RT1210.03-15
12/17/2015
ATL (TST 3782)
Physical Properties
RT1103.01-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.02-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.03-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.04-15
11/07/2015
ATL (TST 3782) .
Physical Properties
RT1103.05-15
11/07/2015
Miami -Dade (CER1592)
HVHZ Compliance
14-0416.12
11/27/2014
Miami -Dade (CER1592)
HVHZ Compliance
15-0721.04
11/05/2015
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.06
02/25/2016
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.07
02/25/2016
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.08
02/25/2016
Tile Roof Institute
TAS 100, TAS 101,102, 102(A)
Membership Confirmation
Current
PRI (QUA9110)
Quality Assurance
Service Confirmation
Exp. 11/02/2018
Exterior Research and Design, U.C. Evaluation Report E39330.11.11-1-R4
Certff7cate of Author7rattan #9503 6EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 2 of 8
4. PRODUCT DESCRIPTION:
4.1 J ,TAS-112, Type 3a
I 16'
1-1/T4'
I
10,
Y
f-- 16'=j
2'
10'
Y I
Bermuda Flat
Q�TMITYIERD
BERMUDA FLAT, PLANTATION FLAT and HORIZON FLAT
y l�.
/-1 T9%4"
Horizon Flat
Plantation Flat
�I
Exterior Research and Design,LLC. Evaluation Report E39310.11.11-1-R4
Certiftate ojAuthorlration #9503 6EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 3 of 8
i
\1111T'R1Nrry ERD
4.2 TAS 112, Type la (interlocking, high -profile) BELLA HIGH
4.3 I TAS M Type 1b
Holes ��
1
Estate "S"
Bella High "S"
profile)
and HACIENDA
Hacienda
Galena Spanish "S" Regal
Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-114
Certificate afAuthorizatlon #9503 67N EDITION 12017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 4 of 8
\I TRINIiYIERD
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements.
5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for
fire rating of this product.
5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations.
5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in
accordance with TAS 112, Appendix W.
5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment
products shall hold current Florida Statewide Product Approval or Local Approval for use in tile roof
assemblies in FBC HVHZ jurisdictions.
5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements.
5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule
61G20-3.
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall
comply with manufacturer's current published instructions, but not less than the requirements of RAS 118,
RAS 119 or RAS 120, as applicable.
6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in
accordance with Roofing Application Standard RAS 127-11 using the data outlined herein.
TABLE I: AERODYNAMIC MULTIPLIERS -a. (FT3)
Tile
Batten Application
Direct -Deck Application
Bermuda Flat
0.189
0.205
Plantation Flat
0.267
0.289
Horizon Flat
0.305
0.330
Bella High "S"
0.349
0.378
Estate "S"
0.267
0.28SAk
Hacienda
0.267
0.289
Galena Spanish "S"
N/A
0.235
Regal
0.287
0.311
TABLE 2: RESTORING MOMENT DUE TO GRAVITY- MG (FT-LBF)
Roof Slope (0)
Tile
2:12<0<3:12
3:12<9<4:12
4:12<0<5:12
5:125A<6:12
6:12<6<7:12
6>7:12
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Bermuda Flat
5.22
6.43
5.17
6.37
5.09
6.27
4.98
6.15
4.86
6.00
4.72
5.83
Plantation Flat
7.22
7.91
6.85
7.79
6.75
7.67
6.61
7.52
6.44
7.32
6.26
7.04
Horizon
7.60
8.32
7.52
8.24
7.41
8.12
7.26
7.95
7.09
7.76
6.89
7.55
Bella High "S"
6.19
6.89
6.11
6.80
5.99
6.67
5.85
6.51
5.68
6.33
5.50
6.13
Estate "S"
6.14
6.84
5.91
6.74
5.82
6.64
5.70
6.50
5.56
6.33
5.40
6.14
Hacienda
5.92
6.80
5.92
6.80
5.82
6.69
5.70
6.55
5.56
6.39
5.41
6.22
Galena Spanish "S"
N/A
6.20
N/A
6.13
N/A
6.03
N/A
5.89
N/A
5.74
N/A
5.57
Regal
7.77
8.34
7.77
8.34
7.65
8.20
7.49
8.03
7.30
7.83
7.10
7.61
Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4
Certiftate ofAothar/zatlon N9503 6T" EDITION (2017) FBC HVHZ EVALUATION FL7804-R30
Entegra Roof Tiles Revision 4:10/17/2017
Page 5 of 8
>�TRINITYIERD
TABLE 3A: ATTACHMENT RESISTANCE' EXPRESSED AS A MOMENT- MF (FT-LBF)
MECHANICALLY ATTACHEMSYSTEMS
Tile
Fastener
Direct -Deck
(min.15/32"
plywood)
Direct -Deck
(min.19/32"
plywood)
Battens
Type
#
Size
Shank
Clip
Nail
One (1)
10d
Smooth or Screw
N/A
7.3
9.8
4.9
Nail
Two (2)
10d
Smooth or Screw
N/A
14.0
18.8
7.4
Nail
One (1)
10d
Smooth or Screw
Eave
19.0
19.0
22.1
Nail
One (1)
10d
Smooth or Screw
Field
24.3
24.3
24.2
Bermuda Fiat,
Nail
Two (2)
10d
Smooth or Screw
Eave
31.9
31.9
32.2
Plantation Flat or
Nail
Two (2)
10d
Smooth or Screw
Field
35.5
35.5
34.8
Horizon
Nail
Two (2)
10d
Ring
N/A
30.9
38.1
17.2
Nail'
Two (2) 1
10d'
Ring'
N/A
50Y
65.51
48.31
Screw
One (1)
#8
N/A
N/A
30.8
30.8
18.2
Screw
Two (2)
#8
N/A
N/A
51.7
51.7
24.4
' Installation with a 4-inch the headlap and fasteners located min. 2h-inch from head of tile.
Nail
One
10d
Smooth or Screw
N/A
8.82
11.81
4.12
Nail
Two (2)
30d
Smooth or Screw
N/A
16.4
21.9
7.1
Nail
One
10d
Smooth or Screw
Eave
19.02
19.0,
22.1'
Nail
One
lod
Smooth or Screw
Field
24.3'
24.32
24.22
Nail
Two (2)
10d
Smooth or Screw
Eave
31.9
31.9
32.2
"S"
Nail
Two (2)
10d
Smooth or Screw
Field
35.5
35.5
34.8
Estate or Hacienda
Nail
Two (2)
10d
Ring
N/A
27.8
37.4
28.8
Nail'
Two
10d'
Ring'
N/A
43.01
67.51
50.91
Screw
One
#8
N/A
N/A
25.82
25.82
22.92
Screw
Two (2)
#8
N/A
N/A
47.1
47.1
49.1
Installation with
a 4-inch tie headiap and fasteners located min. 2X-inch from head of tile.
2 For one (1) fastener installations, utilize hole that is approximately 4'/e-inch from the interlocking edge.
Nail
One (1)
10d
Smooth or Screw
N/A
5.1
6.8
2.8
Nail
Two (2)
10d
Smooth or Screw
N/A
6.9
9.2
7.3
Nail
One (1)
10d
Smooth or Screw
Field
23.1
23.1
19.0
Nail
One (1)
10d
Smooth or Screw
Eave
29.3
29.3
24.0
Nail
Two (2)
lod
Smooth or Screw
Field
27.6
27.6
38.6
Bella High "r Regal Galena
o
Spanish "5" or
Nail
Two (2)
10d
Smooth or Screw
Eave
38.1
38.1
41.8
Nail
Two (2)
30d
Ring
N/A
28.6
41.2
19.4
Nail'
Two (2)1
10d'
Ring'
N/A
33.1'
48.1'
50.91
Screw
One (1)
1 #8
N/A
N/A
20.7
20.7
18.1
Screw
Two (2)
#8
N/A
N/A
43.2
43.2
29.8
Installation with a 4-�Inch tile headlap and fasteners located min. 2Y.-inch from head of tile.
Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4
Certificate of Authorization #9503 6TM EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 6 of 8
rTRINITYI'ERD
TABLE 4: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT- MF (FT-LBF),
'MORTAR AND ADHESIVE -SET SYSTEMS '
Note from Entegra Roof Tile, LLC.: The performance data listed in Table 4 are based on the respective adhesive manufacturers' test
reports and Miami-Dade,NOAs. Entegra Roof Tile, LLC. relies upon the adhesive manufacturers to provide these values for our inclusion
in `this FBC ;HVHZ Evaluation Report. Please•'consult the individual adhesive manufacturer for information on product approvals,
limitations, revisions or other information for determining wind load and overturning moment performance.
Tile Adhesive
Tile
Product
Product Approval
Placement
Mf (ft-lbf)
"TILE BONDTM" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
41
Bermuda
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
73
Flat,
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
52
Plantation
Flat or
Horizon
Polyset® AH-160 by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent (2-paddy)
43
paddy,
Independentmedium p y , — 30 g)
(
51
Independent (large paddy, —45 g)
92
"TILE BONDTM" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
44
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
42
"S"
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
44
Estate or
Hacienda
"Polyset® AH-160" by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent (2-paddy)
50
Independent (medium paddy, ^30 g)
37
Independent (large paddy, —54 g)
61
Mortar
Various
Per RAS 120
21
"TILE BOND'""" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
48
'?ouch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
52
Bella High
"S",
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
36
Galena
Spanish "S"
or Regal
"Polyset® AH-160" by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent (2-paddy)
30
Independent (medium paddy, "30 g)
49
Independent (large paddy, —63 g)
94
Mortar
Various
Per RAS 120
25
7. LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed
below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance
Agency noted herein.
and/or
ENTEIRIRR�'�
Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R4
Certi7cate of Authorization JM503 6'" EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 7 of 8
Y•
�,)TRINITYJERD
and/or
ns.on
Labeling: Horizon Flat, Hacienda, Regal
8. BUILDING PERMIT REQUIREMENTS:
As requirgd by the Building Official or Authority Havl'ng Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Plant
Profiles
Okeechobee, FL
Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Ft. Myers, FL
Horizon Flat, Hacienda
Deerfield Beach, FL
Horizon Flat, Hacienda, Regal
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777
- END OF EVALUATION REPORT —
Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4
certiftate ofAuthorizallon #9503 6EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 8 of 8