HomeMy WebLinkAboutBLOWER DOOR TEST FORMSCANNED Bit S$ Lucie County Date: b( 4 Contractor: M Manning 61 Ijevelopment Services Building & Code Regulation Division 2300 Virginia Ave, Ran 201 Fort: Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM HOUse Intl trretion `Pest Certification Prescriptive and Perrforrmancd Method Permit #° I, o 3-- o[' f l `, M'l in r 1�o5-Di4'1 Job Address: - ! 8 L3 V►rl I d a ,Q pr a e,•c 7 L 3 !t9 t j Construction: 1-D New Construction -- Complete � ( ) ExIs`cing - After Addlft® Blouse Infiltration Test Results SLC Climate Zone 2, - CFM (50) = 13 Z o Test Date: % 14 Volume = 2 ` — l �E If ACH (50) = CFM (50) x 60 / volume = �� 2 Mechanical ventilation required less than 3 ACH Passing results must be"?, ACH (50) or less -Pass , ( ) Fail FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 2 air changes per hour in Climate Zone 1, 2 and 3 air changes per.hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (9) or (B) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FQC, Residential Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name: Pro -Duct Services Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949 I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance witl7,Section R402.4.1.2 Climate Zone 2. Signature: Printed Name: Martin Klein License/Certification #: 5061633 BUILDING PERFORMANCE INSTITUTE, INC. 107 Hermes Road, Suite 210 Malta, NY 12020 (877) 274-1274 www.bpi.org —^ a . Martin Klein BPI BMIEW5061632 CERTIFIED PROFESSIONAL SM (SEE REVERSE SIDE FOR DESIGNATIONS AND EXPIRATION DATES)