HomeMy WebLinkAboutELEVATION CERTIFICATESCANNED U.S. DEPARTMENT OF HOMELAND SECURITY BY OMB No. 1660-0008 Federal Emergency Management Agency R Lucie Coun$y Expiration Date: November 30, 2018 National Flood Insurance Program ELEVATION; CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for (1),community official, (2) insurance agent/company, and (3) building owner. SECTION A — PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owners Name I �`� ' S��tf�0 Policy Number: John M. and Gretchen M. McMinn AQ. Btjilding Street Address (including Apt., Unit, Suite, andio. Box No.. I Bldg. Route and Company NAIL Number. 1828 Wildcat Cove Drive City State ZIP Code Fort Pierce Florida 34949 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) 1425-620-0041-000-1; Lot 48, Riverpointe at the Sands - Phase II A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential A5. Latitude/Longitude: Lat. 27.491928 N Long.80.306298 W Horizontal Datum: ❑ NAD 1927 ❑x NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 1A A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) 0.00 sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade 0 c) Total net area of flood openings in A8.b 0.00 sq in d) Engineered flood openings? ❑ Yes ❑x No A9. For a building with an attached garage: a) Square footage of attached garage 400.00 sq ft I b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 3 c) Total net area of flood openings in A9.b 600.00sq in d) Engineered flood openings? ❑x Yes ❑ No SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State St. Lucie County, 120285 St. Lucie Florida B4. Map/Panel B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) Number Date Effective/ Zone(s) (Zone AO, use Base Flood Depth) Revised Date 12111 C0181 J 02-16-2012 02-16-2012 AE 5.0' B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9: ❑ FIS Profile ❑x FIRM ❑ Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ❑x No Designation Date: ❑ CBRS ❑ OPA FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 1 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 1828 Wildcat Cove Drive City State ZIP Code Company NAIC Number Fort Pierce Florida 34949 SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ❑x Finished Construction *A new Flevation Certificate will be required wheR GORStFUetieA the building is of eemplete. C2. Elevations — Zones Al—A30, AE, AH, A (with BFE), VE, V1—V30, V (with BFE), AR, AR/A, AR/AE, AR/A1—A30, AR/AH, AR/AO. Complete Items C2.a—h below according to the building diagram specified in Item AT In Puerto Rico only, enter meters. Benchmark Utilized: A29, D307 Vertical Datum: NAVD 1988 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 0 NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 6.2 x❑ feet ❑ meters b) Top of the next higher floor N/A ❑x feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) N/A 0 feet ❑ meters d) Attached garage (top of slab) 5.7 ❑x feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building (Describe type of equipment and location in Comments) 6.0 ❑ feet ❑ meters. f) Lowest adjacent (finished) grade next to building (LAG) 5A ❑x feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 5.6 ❑x feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including structural support N/A ❑ meters ❑ feet SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U. S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? ❑x Yes ❑ No ❑ Check here if attachments. Certifier's Name License Number Thomas P. Kiernan 6199 Title Professional Surveyor/ Ice Company Name Culpepper & Terpening, Inc. G d I `r '$1 Address 2980 South 25th Street City State ZIP Code Fort Pierce Florida 34981 Signature Date Telephone Ext. (772)464-3537 206 Copy all pages of this Elevation Certificate and all attachments for (1),community official, (2) insurance agenticompany, and (3) building owner. Comments (including type of equipment and location, per C2(e), if applicable) The elevation referenced in Section C2, item e) is: Concrete A/C pad on left side of structure, EL.=6.0' FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 2 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 1828 Wildcat Cove Drive City State ZIP Code Company NAIC Number Fort Pierce Florida 34949 SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items El—E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Rinntiong A. RAnd r Fnr Itprnq PI—F:4. ijqp naturn] grgrip. Of ;aysilghip rhprk thp mpagurement used- In Puerto Rico only, enter meters. El. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 1-2 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is [:]feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name Thomas P. Kiernan Address City State ZIP Code 2980 South 25th Street Fort Pierce Florida 34981 Signature Date Telephone (772)464-3537 Comments ❑ Check here if attachments. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 3 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number. 1828 Wildcat Cove Drive City State ZIP Code Company NAIC Number Fort Pierce Florida 34949 SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement iie=fjin1f=mar,8=r,jn in Puerto Rico only. enter meters- G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: Elfeet ❑ meters Datum G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters Datum G10. Community's design flood elevation: ❑ feet ❑ meters Datum Local Official's Name Title Community Name Telephone I I Signature Date Comments (including type of equipment and location, per C2(e), if applicable) ❑ Check here if attachments. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 4 of 6 r / BUILDING PHOTOGRAPHS ELEVATION CERTIFICATE See Instructions for Item A6. OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 1828 Wildcat Cove Drive City State ZIP Code Company NAIC Number Fort Pierce Florida 34949 I If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View'; and, if required; "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or in S-R-G-tiei.A.8. if tl� an well fit this use the G- GANAWA-tiG Page. Fents, as submitting FRGPe Ph9tG9Faphs eR page, -A i }� � ,.'r-`4�'�ir�T 7FC,k� t '"t*)'OS�K «'7kC.:1:�'h'ita'...�'3.SI.a,X . � • 'i Photo One I Photo One Caption Front 6/19/2019 ,I Gear Fhoto One 1cunt4 al 1 ..S Survey F i rrs p fl yzTestLabel i �57 *._�'33h1_ _ - 'SL�4�>. edfY' "m� �w��'� f,`'; �O�'`!•' Ow Photo Two Photo Two Caption Rear 6/19/2019 Char Photo Two ^ FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 5 of 6 I BUILDING PHOTOGRAPHS OMB No. 1660-0008 ELEVATION CERTIFICATE Continuation Page Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 1828 Wildcat Cove Drive City State ZIP Code Company NAIC Number Fort Pierce Florida 34949 If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View'; and, if required, "Right Side View' and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. • 80 i •• } 1832 Wildcat• Fort Pierce 'St. Lucie County • • Surveyor: TestLabel ..; 4. all Photo Three Photo Three Caption Right Side 6/19/2019 Glear f - oto Three: .. 1� +V``11tt� it Yv , K jam+ r F+ N Photo Four Photo Four Caption A/C pad, left side 6/19/19 Clear Photo.Foue FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 6 of 6 A ��t SMART VENT' INSULATEDSERIES. This series of vents is ideal for areas requiring flood venting protection but no natural air ventilation. The flood door contains a Z' insulated core that has an R-value of 8.34 and the vent frame Is lined --,# with felt weather stripping, helping to keep the enclosure as insulated from the elements as possible. IDEAL FOR: • Garages i • Full height enclosures (e.g. walkouts) • Conditioned crawlspaces I • Storage facilities -.Metal buildings • Foyers O Flood Vent 1540-520 QStac cer 7540-521 Stacker Models are twice as efficient as a single unit and are a great solution for large amounts of square footage, and in situations where there is not enough wall space to fit in single units. 0 Wood wall 1540-570 Wood Wall Models are designed to fit between studs spaced at 16" on center. Pre -drilled slots in the four corners on the vent flange make for an easy installation. SMART VENT Foundation Flood Vents ® �Rm►a�eCit MODEL NUMBER FLOOD COVERAGE VENT SIZE ROUGH OPENING DIVISION: 08 00 00—OPENINGS SECTION: 08 95 43—VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER:. SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540-511; #1540-570; #1540-574; #1540-524; #1540-514 FLOOD VENT SEALING KIT #1540-526 ICC ICC ICC PMG LISTED "2014 Recipient of Prestigious Western States Seismic Policy Council man (WSSPC) Award in Excellence" A Subsidiary of �oeco eca ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. I There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. iSonEo nose a�au�e ceninra4on eaay #1000 Copyright 0 2019 ICC Evaluation Service, LLC. All rights reserved. IMES Evaluation Report ESR-2074 Reissued February 2019 This report is subject to renewal February 2021. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 08 00 00—OPENINGS Each unit is fabricated from stainless steel. Smart Vent® ec ton: Ots 95 43=Ventolroundation various models and sizes as described in Table 1. The REPORT HOLDER: SmartVENT® Stacking Model #1540-511 and FloodVENTO Stacking Model #1540-521 units each contain two SMART VENT PRODUCTS, INC. vertically arranged openings per unit EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540520; #1540-521; #1640-610; #1540- 511; #1540570; #1540574, #1540524; #1640-614 FLOOD VENT SEALING KIT #1540526 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2018, 2015, 2012, 2009 and 2006 International Building Code® (IBC) ■ 2018, 2015, 2012, 2009 and 2006 Intemational Residential Code® (IRC) ■ 2018 Intemational Energy Conservation Code® (IECC) ■ 2013 Abu Dhabi Intemational Building Code (ADIBC)t rThe ADIBC is based on the 2009 IBC. 2609 IBC code sections referenced in this report are the same sections in the ADIBC. Properties evaluated: ■ Physical operation ■ Water flow 2.0 USES The Smart Vent® units are engineered mechanically operated flood vents (FVs) employed to equalize hydrostatic pressure -on walls of enclosures subject to rising or falling flood waters. Certain models also allow natural ventilation. 3.0 DESCRIPTION 3.1 General: When subjected to rising water, the Smart Vent® FVs internal floats are activated, then pivot open to allow flow in either direction to equalize water level and hydrostatic pressure from one side of the foundation to the other. The FV pivoting door is normally held in the closed position by a buoyant release device. When subjected to rising water, the buoyant release device causes the unit to unlatch, allowing the door to rotate out of the way and allow flow. The water level stabilizes, equalizing the lateral forces. 3.2 Engineered Opening: The FVs comply with the design principle noted in Section 2.7.2.2 and Section 2.7.3 of ASCE/SEI 24-14 [Section ' 2.6.2.2 of ASCE/SEI 24-05 (2012, 2009, 2006 IBC and IRC)] for a maximum rate of rise and fall of 5.0 feet per hour (0.423 mm/s). In order to comply with the engineered opening requirement of ASCE/SEI 24, Smart Vent FVs must be installed in accordance with Section 4.0. 1 3.3 Ventilation: The SmarlVENT® Model #1540-510 and SmartVENT1' Overhead Door Model #1540-514 both have screen covers with 1/4-inch-by-1/4-inch (6.35 by 6.35 mm) openings, yielding 51 square inches (32 903 mm2) of net free area to supply natural ventilation. The SmartVENT® Stacking Model #1540-511 consists of two Model #1540-510 units in one assembly, and provides 102 square inches (65 806 mm2) of net free area to supply natural ventilation. Other FVs recognized in this report do not offer natural ventilation. 3.4 Flood Vent Sealing Kit: The Flood Vent Sealing Kit Model #1540-526 is used with SmarlVENT® Model #1540-520. It- is a Homasote 440 Sound Barrier® (ESR-1374) insert with 21 — 2-inch-by-2- inch (51 mm x 51 mm) squares cut in it. See Figure 4. 4A DESIGN AND INSTALLATION 4.1 ' SmartVENT'3and FloodVENr: SmartVENT' and FloodVENTe are designed to be installed into walls or overhead doors of existing or new construction from the exterior side. Installation of the vents must be in accordance with the manufacturer's instructions, the applicable code and this report. Installation clips allow mounting in masonry and concrete walls of any thickness. In order to comply with the engineered opening design principle noted in Section 2.7.2.2 and 2.7.3 of ASCE/SEI 24-14 [Section 2.6.2.2 of ASCE/SEI 24-05 (2012, 2009, 2006 IBC and IRC)], the Smart Vent® FVs must be installed as follows: ■ With a minimum of two openings on different sides of each enclosed area. ■ With a minimum of one FV ,for every 200 square ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed A as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as 1`-1 to arty finding or other matter in this report, or as to any product covered by the report. Copyright © 2019 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 5 ESR-2074 I Most Widely Accepted at., , isted Page 2 of 5 feet (18.6 m2) of enclosed area, except that the 5.2 The Smart Vent® FVs must not be used in the place SmartVENT® Stacking Model #1540-511 and of "breakaway walls" in coastal high hazard areas, but FloodVENT® Stacking Model #1540-521 must be are permitted for use in conjunction with breakaway installed with a minimum of one FV for every walls in other areas. 400 square feet (37.2 m2) of enclosed area. 6.0 EVIDENCE SUBMITTED ■ Below the base flood elevation. I 6.1 Data in accordance with the ICC-ES Acceptance ■ With the bottom of the FV located a maximum of Criteria for Mechanically Operated Flood Vents 12 inches (305.4 mm) above the higher of the final I (AC364), dated August 2015 (editorially revised grade or floor and finished exterior grade immediately I October 2017). under each opening. 6.2 Test report on air infiltration in accordance with ASTM 4.2 Flood Vent Sealing Kit E283. Tha Flnnrl vent Sealing Kit Model 1540-526 is used in ! 7.0 IDENTIFICATION conjunction with FloodVENTO Model #1540-520. When installed and tested in accordance with ASTM E283, the FV and Flood Vent Sealing Kit assembly have an air leakage rate of less than 0.2 cubic feet per minute per lineal foot (18.56 I/min per lineal meter) at a pressure differential of 1 pound per square foot (50 Pa) based on 12.58 lineal feet (3.8 lineal meters) contained by the Flood Vent Sealing Kit. 5.0 CONDITIONS OF USE The Smart Vent® FVs described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The Smart Vent® FVs must be installed in accordance with this report, the applicable code and the manufacturer's installation instructions. In the event of a conflict; the instructions in this report govern. i 7.1 The Smart VENT® models and the Flood Vent Sealing Kit recognized in this report must be identified by a label bearing the manufacturer's name (Smartvent Products, Inc_), the model number, and the evaluation report number (ESR-2074). 7.2 The report holder's contact information is the following: SMART VENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY 08071 (877) "1-8368 www.smartvent.com info(&smartvent.com TABLE 1—MODEL SIZES MODEL NAME MODEL NUMBER MODEL SIZE (in.) COVERAGE (sq. ft.) FloodVENTO1540-520 15 /4' X 7 /4' 200 SmartVENT® 1540-510 153/a' X 73/4" 200 FloodVENr Overhead Door 1540-524 153/4' X 7314" 200 SmartVENT® Overhead Door 1540-514 153/4' X 73/4" 200 Wood Wall FloodVENTO 1540-570 14" X 83/4" 200 Wood Wall FloodVENr Overhead Door 1540-574 14" X 83/4' 200 SmartVENr Stacker 1540-511 16" X 16" 400 FloodVent® Stacker 1540-521 16" X 16' 400 For SI: 1 inch = 25.4 mm; 1 square foot = mZ FIGURE 1--SMART VENT: MODEL 1540-510 ESR-2074 I Most Widely Accepted ant fisted Page 3 of 5 FIGURE 2—SMART VENT MODEL 1540-520 FIGURE 3--SMART VENT: SHOWN WITH FLOOD DOOR PIVOTED OPEN FIGURE 4—FLOOD VENT SEALING KIT ICC-ES Evaluation Report ESR-2074 CBC and CRC Supplement Reissued February 2019 This report is subject to renewal February 2021. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543'I A Subsidiary of the International Code Council° DIVISION: 08 00 00—OPENINGS I' REPORT HOLDER: SMART VENT PRODUCTS, INC. I EVALUATION SUBJECT: SMART vwrO AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1640-620, #1540.621; #1540-510; #1540.611; #1540- 670; #1640-i74; #1540-624; #1540.514 FLOOD VENT SEALING 19T #1540-526 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Smart Vent® Automatic Foundation Flood Vents, recognized in ICC-ES master evaluation report ESR-2074, have, also been evaluated for compliance with codes noted below. Applicable code edition: ■ 2016 California Building Code (CBC) ■ 2016 California Residential Code (CRC) 2.0 CONCLUSIONS 2.1 CBC: The Smart Vent® Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the master evaluation report ESR-2074, comply with 2016 CBC Chapter 12, provided the design and installation ate in accordance with the 2015 Intemational Building Code® (IBC) provisions noted in the master report and the additional requirements of CBC Chapters 12, 16 and 16A, as applicable. The products recognized in this supplement have not been evaluatedIi under CBC Chapter 7A for use in the exterior design and construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any Wildland-Urban Interface Fire Area. 2.2 CRC: The Smart Vent® Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the master evaluation report ESR-2074, comp with the 2016 CRC, provided the design and installation are in accordance with the 2015 Intemational Residential Code (IRC) provisions noted in the master report The products recognized in this supplement have not been evaluated under 2016 CRC Chapter R337, for use in the exterior design and construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any Wildland-Urban Interface Fire Area. The products recognized in this supplement have not been evaluated for compliance with the Intemational Wildland—Urban Interface Code®. This supplement expires concurrently with the master report, reissued February 2019. IMES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed . as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as u to arty finding or other matter in this report, or as to any product covered by the report. Copyright © 2019 ICC Evaluation Service, LLC. All rights reserved. I Page 4 of 5 I i ICC-ES Evaluation Report ESR-2074 FBC Supplement Reissued February 2019 This report is subject to renewal February 2021. www.icc-es.ora 1 (800) 423-6587 1 (562) 699-0643 A Subsidiary of the International Code Council° DIVISION: 08 00 00—OPENINGS REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENTO AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540-511; #1540-570; #1540-574; #1540-524, #1540.514 FLOOD VENT SEALING KIT #1540.526 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Smart Vent® Automatic Foundation Flood Vents, recognized in ICC-ES master report ESR-2074, have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2017 Florida Building Code —Building ■ 2017 Florida Building Code —Residential 2.0 CONCLUSIONS The Smart Vent® Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the master evaluation report ESR-2074, comply with the Florida Building Code —Building and the FRC, provided the design and installation are in accordance with the 2015 International Building Code® provisions rooted in the master report. Use of the Smart Vent® Automatic Foundation Flood Vents has also been found to be in compliance with the High -Velocity Hurricane Zone provisions of the Florida Building Code —Building 'land the Florida Building Code —Residential. For products falling under Florida Rule 9N-3, verification that the report holder's quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official';when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued February 2019. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as 2 to arty finding or other matter in this report, or as to any product covered by the report ,� ... Copyright © 2019 ICC Evaluation Service, LLC. All rights reserved. Page 5 of 6