HomeMy WebLinkAboutREVIEW-COMMENTSPlanning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462-2172 Fax:(772)462.6"3 REVIEW COMMENTS Page 1 PROPERTY INFORMATION Address: 1828 Wildcat Cove Dr Owner(s): Gretchen M Mcminn / John M Mcminn City / State / Zip: Fort Pierce, FI 34949 Parcel #: 1425-620-0041-000/1 Jurisdiction: SAINT LUCIE COUNTY Zoning: PUD Lot#: 48 Block: APPLICATION INFORMATION Permit Number: 1805-0147 Stories: Automatic Sprinkler System? No Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) I CONTRACTOR INFORMATION i i Contractor Name: Fax Number: Business Name: Business Addr: Email: City / State / Zip: REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released ADDRESSING ASSIGNMENT PENDING Lori Bender 5/14/2018 5/14/2018 5/14/2018 Comment: I DOCUMENTS MISSING PENDING Deanna Givens 5/4/2018 5/4/2018 Comment: ELECTRICAL SUB AGREEMENT 5/4/2018 Comment: PLUMBING SUB AGREEMENT 5/4/2018 Comment: HVAC SUB AGREEMENT 5/4/2018 Comment: ROOFING SUB AGREEMENT 5/11/2018 Comment: PLEASE PROVIDE RECEIPT FROM SLC UTILITIES. 5/11/2018 Comment: PLEASE PROVIDE LETTER FROM FPL STATING THERE IS ELECTRIC SERVICE AVAILABLE IN THAT AREA. ENVIRONMENTAL REVIEW COMPLETE Lynn Swartzel 6/9/2018 6/14/2018 5/14/2018 Comment: FRONT COUNTER REVIEW COMPLETE Deanna Givens 5/4/2018 5/4/2018 5/4/2018 Comment: PLANS EXAMINER REVIEW PENDING Joseph Fersch Comment: PLEASE NOTE THAT, THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE 5/29/2018 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. Comment: DESIGN WIND SPEED APPEARS INCORRECT. PLEASE REFER TO THE ST LUCIE COUNTY ULTIMATE 5/29/2018 DESIGN WIND SPEED, WHICH CAN BE VIEWED AT THE COUNTY WEB SITE STLUCIECO.GOV. PLEASE REVIEW PLANS AND MAKE CORRECTIONS. Planning & Development Services REVIEW COMMENTS Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(7721462-2172 Fax:(772)462-6443 Page 2 Comment: EASE FURNISH ENERGY CALULATIONS AND MANUAL J IN ACCORDANCE WITH SECTIONS 402 AND 403 5/29/2018 F THE 2014 FLORIDA ENERGY CODE. NOTE ONLY; ENERGIES MUST HAVE ORIGINAL SIGNATURE OF PREPARER 5/29/2018 Commen PLEASE FURNISH TRUSS SHOP DRAWINGS INCLUDING ALL CUT SHEETS IN DUPLICATE PER 107.2.1 OF THE 2017 FLORIDA BUILDING CODE 5/29/2018 / mment: LEASE SHOW AUTOMATIC GARAGE DOOR OPENER BEING IN ACCORDANCE WITH 309.4 OF THE 2017 v LORIDA RESIDENTIAL CODE SIXTH EDTITION. Comment: PLEASE FURNISH FLASHING DETAIL ON PLANS FOR ALL EXTERIOR WINDOWS AND DOORS. SEE SECTION 5/29/2018 4612.10 FLASHING, SEALANTS, AND WEATHER STRIPPING, AND R703.8 FLASHING OF THE 2017 FLORIDA RESIDENTAL BUILDING CODE. 5/29/2018 Comment: EASE FURNISH AN INTERIOR SEPERATION WALL DETAIL BETWEEN THE GARAGE AND RESIDENCE ACCORDANCE WITH R302.6 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDTITION. Comment: PltASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING 5/29/2018 THE SQUARE FOOT INFORMATION. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. 5/29/2018 Comment: ,LEASE FURNISH PROTECTION DETAIL ON PLANS FOR APPIANCE INSTALLED IN THE GARAGE SEE SECTION M1307.3 i1 IN ACCORANCE WITH THE 2017 FLORIDA RESIDENTAL BUILDING CODE. 5/29/2018 Comment: PLEASE FURNISH,A MECHANICAL PLAN IN ACCORDANCE WITH 107.2.1 & 107.3.5 OF THE 2017 FLORIDA BUILDING CODE SIX EDITION ZONING REVIEW COMPLETE Angela Huff 5/10/2018 5/11/2018 5/11/2018 Comment: