HomeMy WebLinkAboutBUILDING PLANPERMITTING INFORMATION (FORM 100)
Entegra Bella Hlggh "S" Roof Tile Installed per product
approval FL# 1804.2 and evaluation report using
(2) IOd ring shank nails over ppolyglass self adhered
roofing underlayment over 19/52" CDX plywood attaqhi
to trusses per sheeting attachment diagram on roo
-O" T
A.F.F.
5/8" thick light textured
stucco on typical concrete
block construction
Smooth finished stucco band
FRONT ELEVATION
Entegra Bella High "S" Roof Tile installed per product
approval FLU 1804.2 and evaluation report using
(2) IOd ring shank nails over ,,polyglass self adhered
roofing underlayment over 19/32" CDX plywood
to trusses per sheeting attachment diagram o I
A.F.F.
5/8" thick light texture(
stucco on typical concrete
block construction
�J
0
12
,-SLOPE 14
12
SLOPE 4
12
smooth finished
'stucco band
2"
SCALE: 1/4' - I' -Off
Loil
REAR ELEVATION
SCALE: 114' - 1'-0'
Florida Building Code Residential: LTH Edition g
Building Design is: Enclosed Risk Category: II Wlnd Spead: ILI mph ultimate
Mean Roof Height: IC- " Roof Pitch: IL:2
Internal Pressure Coefficient: ±0-18
Subjectability to damage from: Weathering: Negligible Termites: Ver4- Heavu
Width of Roof End Zone: 5'-4"
Wind Exposure Classification: C
Adjustment factor for Exposure Height Using Allowable Stress Design and
Load Combination per ASCE 1-10 Section 2.4 DL+LL; DL+O.LWL; O.LDL+O.LWL
Exp Height Ad j Factor: 1.29 x Load Combo Factor 0.4 = 0.114 applied below
Components It Cladding Wind Pressure (NET) Roof Zone: I. +21.0/-33.0 psf
Roof Zone: 2. +21.0/-51.0 pef
Roof Zone: 3. +21.0/-84.0 psf
Components t Cladding Wall End Zone Width: 5'-L"
Components t Cladding Wind Pressure (NET) Wall Zone: 4. +3L.0/-39.0 psf
Wail Zone: S. +34.0/-48.0 psf
Components It Cladding Wind Pressure (NET) on Garage Door: +32.0/-41.0 psf
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided? Yes
Are Components an Cladding Details Provided? Yea
Minimum Sal Bearing Pressure:2.500 psi, Presumptive: X By Teat: psi
This Building Shall Have the Following:
APPROVED SHUTTERS: IMPACT GLASS: X DOTH: NEITHER:
V
THAN 1 2 1MTCH�
0 Roof Zone 1 ® - Roof Zone 1
Walls Zone 4 Walle Zone 6
END ZONE
GASLR ROOF FROM
242 TO 1112 PITCH
Corner Zones
Root Zone 3
el
---i
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhead Doors, Sliding Doors, Windows & Skylights
Opening
Type
NOA/FL
NUMBER
product
Model #
M nufacturer
Glass
Attachment method
TT
Expiration
Da
ig um
Des ] Bsl
of Approved Testa
1.
15-0L12.12
Single Hung
Series SH-50
Thermal Impact
PGT
Type "BI"
Concrete: 1/4" dia. Tapcons w/ min. 11/2" ppenetration
spaced per testing requirements stated in NOA
1-8-19
+ 80.0 PSF
—
2.
15-0412.13
Fixed Glass
P111-520
Thermal Impact
PGT
Type "Cl"
Concrete: 1/4" dia. Tapcons w/ min. 11/2" penetration
spaced per testing requirements stated in NO A
1-8-19
+ 80.0 PSF
—
3.
11-0504.05
French Door
FD-5555
Impact
PGT
1/IL°
Type A
Head t Sill: 1/4" dia x 3" Tapcons with 1 1/2' penetration
at G" max from corners.
Jambs: II" o.c. max from corners at 18" o.c. thereafter
1-23-19
+ 15.0 PSF
—
4.
I1•-0420.05
Sliding Glass
Series 110
Impact
PGT
3/8"
Type A
Head t Sill: 1/4" dia x 3" Tapcons with 1 1/2' penetration
at G" max from corners.
Jambs: 11" o.c. max from corners at 18" o.c. thereafter
5-22-18
+ 90.0 PSF
—
5
FLU 8248 9
Steel Overhead
Garage Door
8100 Series
Raised Panel
Ufa ne Dalton
y
Per Plans - I/2" x L" &leve anchors et 10" o.c.
+ 4(.O/-52 PSF
6.
Product
NOA/FL
NUMBER
Model #
Manufacturer
Attachment Method
TEST
Ezpiration
Date
Des n�>� ure
of Approved Teats
Mullions
_
Roof
FLU 1804.2
BELLA HIGH "S„
BARREL TILES
(NON HVHZ)
Entegra Sales Inc.
nsta pper pro uct approva and ail re e-rence stan ar s
over Polyglass Self Adhered -.)nfirg system Installed
per FL# 5259.1 over 19/32' 00>7 plywood sheeting
attached per sheeting attachment diagram on roof plan.
Siding
STUCCO
ON BLOCK
5/8" Thick light textured stucco on typical
Concrete block construction
Soffit
STUCCO
ON LATH
1/2" thick stucco on 3/8" HrRib lath attached to
horizontal and vertical wood framing with nail& or staples to
provide no less than 1 3/4" penetration Into horizontal
wood framing and /4" penetration into vertical framin
Hurricane
Panels
08-OL23.06
0.050 Aluminum
Storm Shutters
Eastern Metal
Supplu Inc.
Provide 1/4" dia. ELCO Male/Female "Panelmate" with min.
2" penetration and 1/4"-20 machine screw with nut at L" o.c.
for installation Section 48
9-1-13
+ 43.0 PSF
ALL Product Testing by: Miami -Dade County Building Code Compliance Office / Product Control Division
I have
reviewed the above and approved it by my seal below. ( Architect or Engineer of Record )
��� L0
ST. LUCIE (AUNTY BUILDIN DIVISION
REVIEWED FOR COMPLIA, I!
REVIEWED BY '
DATE
PLANS AND RMIIT MUS BE KEPT ON JOB
SITE OR NO INSPECTION($] WILL BE MADE
JUN 2 1 ZZ18
ST, Lucie COu_YY.
MIM
u_
U-
zil
c
v
�
�
U
v
�
QC
v
L. i 00 M
to4Lnm
N
�NV
a1
CI S
0
vi
Coco
Iv N
�
—
a
1
e,V1c
c
v
r
O
N ,"-_aW
x
E
!L
Q ~ IL
I
W
W
70a
Sheet
l .
OF
Comm >t
18-40
FILE COPY
12
6 SLOPF�
A.F.F.
LEFT ELEVATION
Entegra Bella Higgh "S" Roof Tile Installed per product
,3proval FL# 180'4.2 and evaluation report using
IOd ring shank nails over ppolyglass self adhered
roofing underlagment over 19/52" CDX plywood attached
to trusses per sheeting attachment diagram on roof plan.
12
6 SLOfi�r
12
6 JSLOPS
12"
H.
0
Ipe
5/8" thick light textured
stucco on typical concrete
$ block construction
7.
�I
5/8" thick light textured
stucco on typical concrete
block construction
12
SLOPE 6 ':
12
SLOPE 6
z
O
U
w
Q
U
2
12
LOPE 6
to
O
SCALE: 1/4' = I'-O"
metal track 20
6/8" drywall ceiling on
truss bottom cord
" drywall on
x 4' 20 gauge metal studs at 11" o.c.
track
4" concrete slab with fibermesh OR
Typical baseboard 4"xb" #10/10 WWM on b and Visqueen over
clean compacted termite treated fill
Interior Nor —Bearing Partition
Scale: 1/2" = I'-O"
A.F.F.
12" x 12" concrete column block
H. filled with concrete and (4) US bars
Vert, w/ stucco finish and decorative
stucco capital and base
JV ""; V Z I —V
W
q 0
Tod uo
O
i='1
M
Q
c �O
� jaom NO
�dLDM O
C CV N U 0
C OD OD E
!0 I O Q
00 #
1 ON
iJ-1 Vu1 UI r n`
� w --j V- to e
Q IL I
10
OF
Sheet
2,
Comm #
18-40
Square Footage Breakdown
Proposed A/C Space = 2341 sq.
Covered Porch Total = 386 sq.
Garage = 520 sq.
Floor Total = 3520 sq. ft.
Cubic Volume of Conditioned Space
Total = 23,410 cu. ft.
I
Door Schedule
Mark
Size
Door [Description
A
3'-O" X 8'-On
SINGLE LITE FRENCH w/ SIDELIGHTS
B
(3) 3'-O" X 8'-O"
SLIDING GLASS DOORS
C
(4) 2'-L' x 8'-0'
SLIDING GLASS DOORS
D
2'-0 x 8'-0'
FRENCH DOOR SINGLE LITE
E
2'-a' X li
SOLID CORE - WOOD - L PANEL - 20 MIN FIR
F
IL'-O" x 8'-0'
GARAGE DOOR
G
2'-8" x 8'-0"
SOLID CORE - WOOD - L PANEL
H
3'-0" X 8'-0'
BI-FOLD DOORS
J
4'-On X 8'-O'
BI-FOLD DOORS
K
(2) 2'-O" x 8'-O'
SOLID CORE - WOOD - L PANEL
L
3'-0" X 8'-O"
SINGLE BI-FOLD DOOR
M
2'-L' X 8'-O"
SOLID CORE - WOOD - L PANEL - POCKET
N
2'-8" X 8'-O"
SOLID CORE - WOOD - L PANEL- POCKET
P
3'-0" X 8'-O"
SOLID CORE - WOOD - L PANEL - EXTERIOR
-
-
-
-
ALL exterior doors including garage doors to withstand
pressures stated in permit information box on these plans.
verify all masonry/rough opening sizes prior to ordering
Windows.
See product approval chart on these plans for exterior
door manufacturer information (including garage door)
Provide one exit door (swing type) that is 3'-0" wide
minimum and one emergency escape door (not shuttered).
If escape door has glazing then it must be impact resistant
and shall NOT be thru garage. This may be the same door
if it meets both criteria listed above.
Window Schedule
Mark
Size (wxl)
Window Description
I.
3'-I' x 4'-2"
SINGLE HUNG
2.
3'-1" x L'-4"
SINGLE HUNG
3.
4'-0' x I'-L"
FIXED GLASS TRANSOM
5.
6'-2" x 4'-4'
FIXED GLASS
L.
2'-2' x 4'-2"
SINGLE HUNG
1•
3'-1" x 5'-3'
SINGLE HUNG - EGRESS
S.
I'-8' x 4'-2"
SINGLE HUNG - TEMPERED
9.
3'-I' x 4'-2"
SINGLE HUNG - TEMPERED
10
3'-I" x I'-4"
transom
11.
3'-1' x 2'-2"
SINGLE HUNG - TEMPERED
- ALL Windows to be white ESP aluminum windows with tint.
Provide muntin's and structural mullions per elevations. See
product approval chart for window manufacturer
information.
- ALL windows to withstand Pressures stated in
Permit
Information Box on these plans.
- ALL windows in bathrooms to be tempered
- ALL windows within 18" of finished floor to be
tempered
unless impact rated.
- verify all masonry/rough opening sizes prior to
ordering
Windows.
SEAL CONCRETE BLOCK AT DOOR AND WINDOW
OPENINGS WITH CONCRETE SEALANT
PRIOR
TO BUCK INSTALLATION PER FBCR
-103.8
FLOOR PLAN
I.
Contractor to verify ALL notes and dimensions prior to
proceeding with work.
2.
Contractor to STRICTLY enforce ALL OSHA Requirements.
3.
ALL Lumber to be used as Beam, Rafters, etc... to have
a minimum 1,400 P.S.I. fiber stress.
4.
No dissimilar metals to touch.
S.
ALL Concrete used for slabs shall be 3000 PSI concrete, and
ALL Concrete used for vertical filled cells, continuous. tie beams etc.. to
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix
4.
Drywall at ceilings shall be leveled and attached to bottom chord
of trusses with screws.
1.
ALL wood in contact with concrete shall be pressure treated.
8.
ALL wall dimensions are nominal and not finished wall or stud dimensions.
9.
ALL plumbing fixtures to be low flow.
10.
Contractor to Provide Pan 4 Drain at water heater in accordance
with the Florida Plumbing Code current edition.
11.
Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements.
12.
Lowest finished floor to be set by Governing Building Department
surveyor to set in field.
13.
Separation between residence and garage shall be per FBC R309.1 and R309.2
14.
Door between garage and residence shall be 1-3/8" solid wood - 20 min.
fire rated
15.
The Garage shall be separated from residence and the attic area by 5/8"
type "X"
drywall applied to garage wall.
14.
Wall and Ceiling shall have a flame -spread classification of not greater than
200
I1.
Wall and ceiling finishes shall have a smoke -developed index of not greater
than 450
MEM
SCALE 1/4" = I'-
18. All exposed attic Insulation materials Installed on attic floors shall have a critical radiant
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
materials exposed on the underside of the roof deck or on the attic walls shall comply
with F.B.C. Residential Section R314 - see permit info box of code edition
19. Gyypsum board material shall conform to ASTM C36, C19, C415, C514, C430. C931
C40, C1002, C1041,C1111, CI118, C1218, C1395, or C1394 and shall be installed
according to the following:
Drywall
Thickness
location
Orientation
�ra%mg
en or
Max spacing
fasteners
Nail sin Lions for
61
Spaein
of
installation dr II into
yWwuee
Naib
Screw-
Mawmu�
rood mbers
2' xx min.n it icri aee"
calling
Perpendicular
24"
1•
12'
139a 1 3/8' long with 19/64' head
Rter
0,018' diam x 1 1/4' Ionp
�q I
annular -ringed or 6d coder roil
0.080' di . X 1 5/8" Ion 9 with
Wails
Direction
1L,
8'
16•
15/64' head
OR
xyp56w92��a
/3
/8i head.
Ceiling
Perpendicular
24'
1'
12'
1308 1 5/8' long with 19/64' head
OR
0.018" dia"tor x 1 3/8' long
„
annular -ringed or Ld cooler nail
0.012' din. x 1 1/8" long with
walls
Either
61
8•
16'
Direction
1/4 head
OR
Gypsum board rod 0.0915' die.
X 11/8' sit 19/64' hoed.
�w z i zo�a
Si. Lucie County, Permitting
20. ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.4
A108.1, A118.1, A118.3, A134.1 and A131.1
21. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR C1118 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas.
o I
q
O
L
1L
LL
L
a
c
u
O
U
'
�
u
�Q Ln0
N
U
NN
c ,r,r OD M
E
CO-
10
40 N N
u
oviWrr�
.a►
s
` vxE
..
�Q
~�
I
UJ
Sheet
OF 8
Comm #
Filled Cell Masonry Column With One
#5 From Footing To Beam.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
4" concrete slab with fibermesh OR
6 x6 410/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
/ a #5 bar cont.
(V
m
45 bar Vert. w/
30" overlap
SEE TYPICAL
p
at each Filled cell
ECTIONS
O
N
4" concrete slab
with fibermesh OR
O
I" recess for
VxV #10/10 WWM on 10 mil Visqueen
over -
waterproofing at slab
clean com acted termite treated fill
4' long #�, slab
bars at each
fill
cell
tgr
rade
41
— �
Iil x
14"d concrete monolithic
footing
with (2) #5 bars
Cont.
i)
and #5
transverse bars at 32'
o.c
v
6"
F-16 FOOTING
DETAIL
SCALE 1/2" = 1'-0"
Termite Protection for New
Construction as per F.B.C. 181LI
CONTRACTOR TO REFERENCE F.B.C.
BUILDING 1816.1 FOR FURTHUR REQUIREMENTSE
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment,
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
o_
Treatment must be in accordance with the rules and laws
established by the Florida Department of Agriculture and
consumer services.
Protective sleeves around piping penetrating concrete
slab on grade floors shall not be of cellulose -containing
materials and shall have a min. wall thickness of 0.010"
and shall be sealed within the slab using a noncorrosive
clamping device to eliminate the annular space between
pipe and sleeve. NO TERMICIDES shall be applied
inside the sleeve per FBC Plumbing 305.1.2
FOUNDATION FLAN
IN
IIIIII — —I
L — EP
I— °O
F 12
I
I
I 4„
-8
I
I
SLOPE 2"
I
r -+ —
I I I
L 4 4-al
I
I
I
I
I
18 4„
I
Thicken I obting at corner
as shown fdr uplift from
beam abo '1 dwith #5 bars F-1
at 8" dcl max spacing
1
r 60�'
I-i—i-i- -
L —
Thicken edge to 8"xB"
with concrete and
one #5 bar continuous 4" concrete slab with fibermesh OR
\ Vx6" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
SCALE 1/2" = 1'-0"
82'-2"
Single Filled Cell Column
NTS
Filled Cell Masonry Column With One
#5 From Footing To Beam Each.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Double Filled Cell Column
NTS
'Ju
Iii
111
LI
I I IL3jl
I I I
°
r--
--
---
---
---
----------
--
---
--
----
-
-
--
---
---
--
--
-
— — — —
— — —
— — —
---
F-16
4
Recess
for
F-l6
°
"
K
*----.Shower
I
I /
4' long #5 slab bars at
each fill cell typical
�
Fill cell with concrete and
F 16
4" concrete slab
with fibermesh OR
2'-6"
O
(U #5 bar vert. (typical).
Max. spacing shall not exceed
to I
m
6"x6" 410/10 WWM
on 6 mil Visqueen over
Q
N
_
o
32" unless otherwise noted F-16
see foundation plan notes for I
I
l
clean compacted
termite treated fill
spacing at openings
I
I
4' long 1*5
slab
bars at each
fil
cell ty
ical I
I
F-24
F-�`
-16
l
° -----
----------- ------
I-F-2
-
---------- ------
rior Bearin �
---
-----------------------------=
Int eriOr Bearing Wall
r— ------ 34'-4,------------------------ I
---------------------- --------------
°
Inter ior Bearin Wall
4° tea T — g
r--------------
w I ntenor Bean Wall —
1IXXXXXXXXXXXXXXXXXXX�Xx °�
I
I 4'-4" v ---------------- — v
4" concrete slab with fibermesh OR
6"x4" 410/10 WWM on 6 mill Visqueen over
clean compacted termite treated fill
NF - 3 �whwaaherll O�O
"
(2) #5 bars
vert. here
4' lonc #5 I
-I(o
H.B'
bars, at each fill cell ty
SCALE: 1/4" = 1'-0" Exterior face
FOUNDATION NOTES: of wall
I. Any changes to plans must be submitted to the architect
for approval before proceeding with construction.
2. Contractor shall be responsible for verification of all
memo?m
Rol
30
4" concrete slab with fibermesh OR
6 x6 410/I0 WWM on 6 mil Visqueen over
clean compacted termite treated fill
Pill cell with concrete and
(U 45 bar vert. (typical).
Max. spacing shall no exceed
32" unless otherwise noted
see foundation plan rotais for
- - - spacing at openings - - -
Attach door to block wall with
1/4" dia. x 3" tap -cons with min.
1 1/2" penetration at 12" o.c. max
and 6" o.c. max from each corner thru
I" x 8" PT Buck
rIOtatlOn and dimenslonS bef ore starting construction. caulk - �1"xS" P.T. Buck
3. Soil conditions assumed to be 2500 psf. Should any other conditions be 1 2 sides t header
encountered, the architect shall be notified in Writing for revision Detail at Exterior Doors
4 Verif all recess thickness at showers the etc NTS
5.
30
4" concrete slab with fibermesh OR
6 x6 410/I0 WWM on 6 mil Visqueen over
clean compacted termite treated fill
Pill cell with concrete and
(U 45 bar vert. (typical).
Max. spacing shall no exceed
32" unless otherwise noted
see foundation plan rotais for
- - - spacing at openings - - -
Attach door to block wall with
1/4" dia. x 3" tap -cons with min.
1 1/2" penetration at 12" o.c. max
and 6" o.c. max from each corner thru
I" x 8" PT Buck
rIOtatlOn and dimenslonS bef ore starting construction. caulk - �1"xS" P.T. Buck
3. Soil conditions assumed to be 2500 psf. Should any other conditions be 1 2 sides t header
encountered, the architect shall be notified in Writing for revision Detail at Exterior Doors
4 Verif all recess thickness at showers the etc NTS
5.
Contractor to provide filled cell with concrete and I 4S bar vert. at
32"
o.c. max. Provide (1)
filled cell on each Side of openings Up
to 5'-11"
Wide.
Provide (2) filled cells on each side of openings from 6 —0" to q'—II"
and Provide (3) filled cells on each side of openings from 10'—O" and
up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 24" o.c. unless otherwise noted (see section)
L
Contractor to provide for Form Board Survey — Form Board Survey
to be provided to Truss Company prior to truss construction
Exterior face
of wall
1.
Contractor to provide for soil test prior to construction and provide
71=
a copy of soil test to architect for review prior to construction
8.
ALL Reinforcing steel shall be grade l meeting ASTM A-I6 and
A-36 SpeclflcatlonS. ALL
Anchors
to
be A-301
steel.
Attach window to block wall with
1/4" dia. x 3" tap -cons with min.
1 1/2" penetration at 12" o.c. max
and 6" o.c. max from each corner t
I" x 4" PT Buck
\ / caulk
9. Provide a minimum of 3" concrete protection at footings and Detail at Windows
1-1/2" concrete protection at bums for ALL reinforcing bars.
10. Contractor to provide the Architect with truss shop drawings including
ALL truss cut shhi showing ALL truss, reactions prior to START
x4" P.T. Buck
sides t header
NTS
H.B.'
I
I
I
I
I
SLOPE 211
1
010 I
o
CY
ILL
I
I
4" concre a slab with fibermesh OR I
6"x6" 1*10/1 WWM on 6 mil Visqueen over I
clean comp cted termite treated fill
I
I
tl PC t F-�_4---
om�- - --- her (-- --- --- --
A/C
#I
<r
m
I
45 bar vert. Typical Masonry Wall
at filled call
3�a,i
.. . .
6,
Control Jant Extend Joint reinfori
at 30'-0" max. into concrete column
PLAN VIEW PLAN VIEW
AT A AW eoanm.. U
Typical Masonry Wall
"at ALL T-mtersectia,e
Ell
PLAN VIEW PLAN VIEW
W
AT ALL T IMai1NC & AT ALL �
TYPICAL CONCRETE BLOCK WALL REINFORCING
TO BE DUR-O-WAL DA3100 PREFABRICATED SINGLE
WYTHE TRUSS IN STANDARD WEIGHT WITH A HOT
DIPPED GALVANIZED FINISH. REINFORCING SHALL
BE PLACED IN ALL CONCRETE BLOCK WALLS AT
IL" O.C. VERTICAL OR EVERY OTHER COURSE OF BLOCK
TYPICAL MASONRY WALL
REINFORCING DETAILS
NTS
r
a
q �r
Ll
v U
O
LL
u
U
a
a
O
N
U_
C
O
u
7
a
�
N
<
n
C_>aDm0
°' Ln OD ,c
Q
C N CV u
C aj OD OD E
C
CL O OD OA
0 CV to
N
AaUCA6
v
MM
UWr-r�
+_+
C
I
v
w
Sheet
�T
OF 8
Comm #
18-1f0
TRUSS BRACING NOTES
and roof trusses in the following manner:
- Install first row of truss bracing 3L" from exterior walls
and spaces 12" o.c. thereafter top and bottom chords
- Install bracing on any top or bottom chord which is longer
than 12" in clear span.
All truss bracing to be 2" x 4" wood and shall be attached to
top of bottom chord and on bottom of top chord of trusses.
:11_11 L_r_...
ame spaced per truss
ufactures plans
aical splice
.Lath bracing to truss chord
ig (2) IOd nails in all
ations
x 4" wood bracing
ROOF FLAN
TYPICAL ROOF NOTES:
SEE PPAP ('l)I IIMM r'AP
Max Uplift = 3965 Ibs 18'-4"
Scab I/ern _ i_O"
— Overhangs
shall
be
2'-0",
l'O" in front
unless
otherwise noted on t
— roof pitch
shall
be
(:12
unless
otherwise
noted
on this
sheet
— Truss shop drawings to be provided by manufacturer
— Any changes to this plan shall be submitted to the
architect for approval in writing prior to starting construction.
— ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
— Architect to review Truss Shop Drawings Prior
to construction for layout and uplift verification
— Contractor to provide for Form Board Survey and to provide
Form Board Survey to Truss Company prior to truss construction
— Contractor to provide the Architect with truss shop drawings Including
ALL truss cut sheets showing ALL truss reactions prior to START
OF FOUNDATION WORK for strap and footing size verification.
ROOF SHEETING
ATTACHMENT DETAIL
I. Minimum Nall Size = 8d ring shank (min. 2" long)
2. Minimum Screw Size = 48 x 2"
3. Minimum Sheathing Thickness 19/32" COX PI wood
-4. Use nails or screws based on pressure for roo� stated
in permit info box on these pans for zone 3
s sh
Ke
Area
Ede
Field
Fastener
Pressure
Zone I
6
8d ring shank
45 psf
Zone 2
4"
6"
8d ring shank
% psf
Zone 3
14"
8d ring shank
84 psf
** Zone 2,a
�"
6"
#8 wood screw
112.5 psf
** Use nails or :,crews based on pressure for roof stated
in permit info box on these plans for zone 3
Additional Precast Lintel _
tts bare
Lintel
Bar
Clear
"A"
Bu
CLEAR
Length
Length
Span
Bars
Bars
2'-10"
2'-8"
I'-6"
2,#3
none
I ;;�t.::•:�. i I.: , : I
i i i i i
CLEAR
3'-6 "
3'-4"
2'-2"
2.#3
none
8F8-OB/IT 8F8-IB/IT 8F8-IB/2T
' Additional
tt5 bars
CLEAN
One Row of "H"
Block Above
%t ?'•�' '
Precast Lintel r �;y:.. sl
- Addition "'•''' I
CLEA #5 bars
4'-0"
3'-10"
2'-8"
2,#3
none
3'-2"
2.43
none
5'-2"
4'-O"
2,43
none
5'-10'
S'-8"
4'-6"
2.91
none
2.#4
none
1'-6"
�'-O"
6'-2"
2,45
none
BFIL-IB/IT BFIL-IB/2T
NOTES:
8'-4"
1'-10"
1'-0"
2,45
none
ALL reinforcing steel is grade 60.
I. min. coverage of steel-1.5"
2. min. bearing required a ea. end=8"
3. standard for reirf. steel=ASTM A61'�
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
LINTEL SCHEDULE
Mark
window
or D
Unit
widt
Lintel
Size
Cast -Crete
S ecifica 11
Rows or
"H" Block
Abova
Bottom
Steel
S'u
Top
Steel
51zs
Max.
Gravity
Load
(PLF)
Max.
Uplift
Load
(PLF)
Max.
Lateral
Load
(PLR)
L22
2'-2'
3'-6'
SFB-OB/IT
1
#5
300
15L9
1024
L31
2'-4'
4'-0"
SF8-OB/IT
1
#5
25LI
13L3
1L3
L45
4'-5.
5'-10'
SF8-015/IT
1
#5
1105
909
339
L50
5'-0"
4'-6'
BPS-OB/IT
1
#5
1238
835
121
L60
4'-8'
1'-6-
BPS-OB/IT
1
#5
1011
121
534
LBO
8'-0'
T-4"
BF8-I5/2T
1
#5
1 2
#5
152
591
512
L90
9'-0'
O'-L"
8F8-I13/2T
1
#5
1 2
#5
643
530
401
L90B
9'-0'
10'-6'
BFIL-I5/2T
ONE
I
#5
2
#5
1533
1183
401
LI00
10'-0'
11'-4'
8F8-I13/2'r
1
#5
2
#5
582
494
452
LIOOB
10'-0'
ll'-4'
BFIL-I5/2T
ONE
1
#5
2
1 #5
1 134L
1028
452
LI20
12'-0'
13'-4"
SF8-8/2T
1
#5
2
#5
1 411
428
324
L120B
12'-0'
1 13'-4'
81`I4-I5/2T
ONE
1
15
2
#5
1015
110
324
L140
14'-0'
15'-4'
8FIL-0/2T
ONE
1
85
2
#5
1250
609
259
LILO
W-O'
IT-4"
8F8-I5/2'r
I
#5
2
#5
300
192
194
L160B
W-0"
IT-4'
8F1L-IB/2T
ONE
1
85
2
a5
950
500
1 194
- ALL LINTELS SHALL SE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED.
- CONTRACTOR TO VERIFY ALL LINTEL SIZES BASED ON FINAL MASONRY
OPENING SIZES AND .ADJUST LINTELS ACCORDINGLY PRIOR TO ORDERING
ANY/ALL LINTELS
IA
0
;11
t'(1
-� O
WQt�namo �O
01CV UU
C y, 00 00 E
R I 1 0d
o"fu
"
C4
cr
6-
t! N
ss
a► L_''f' (9 E IL
< ~ IL 1
U! `
Q
M� N
!JJ
Sheet
OF 8
Comm #
18— 40
2" x 6" PT wood secured with
1/2"dia. x 6" anchor bolt at 18" o.c.
overhead door track secured to wood
jamb per manufacturer's specs
Garage Door Jamb Detail
NTS
ALL GARAGE DOORS TO BE WAYNE DALTON
8000 SERIES GARAGE DOORS WITHSTANDING
PRESSURES STATED IN PERMIT INFO BOX ON
THESE PLANS
ICI
I
II
II
II
I
I I
II
II
II
II
II
IL
_�
E
O
cn
IL
30" min.
Corner Steel Lap
nts
Entegra Bella HIgh "S" Roof Tile installed per product
approval FLU �89 4.2 and evaluation report using
(2) IOd ring shank nails over olyglass self adhered
roofing underlayment over 19/�2" GDX plywood attached
to trusses per sheeting attachment diagram on roof plan.
Simpson HETA 20 or equal
hurricane anchor et each truss 12
with (10) IOd x 11/2" nails
( 24" supporting Max.
180605 Ibs. uplift
Galt' -Alum Metal drip on
I" x 4" Drip on
I" x 8" Fascia on
2" x L" Sub -Fascia
1/2" thick stucco on 3/8" hi -rib lath
attached to horizontal and vertical wood
framing with nails or staples to provide
no less than 1-3/4" penetration into
horizontal wood framing and 3/4" penetration
into vertical wood framing members
5/8" thick light textured
stucco on typical concrete
block construction
"4" to late 5/8" Type "X" drywall
P P ceiling on truss bottom cord
z
O
F
U
W
J
4 5/8" Type "X" drygwall on
U 2" x 4' atude at IZ" o.c.
H
w
W
in
Typical baseboard
2" x 4" P.T. bottom plate
Interior Seperation Wall Detail
Scale: 1/2" = I'-O"
PRE-ENGINEERED TRUSSES
> at 24"o.c. TYPICAL
( ahop drawings by manufacturer )
R-20 foam insulation typical
R—II foam insulation over garage and entry
1/2" dr wall over
I"x furring strlgpe at 16o.c. with
R-4.3 celotex insuiation/fyfoil on
/ 8" concrete block
(Duro-Rock is to be provided at
all wet areas. - ex. showers)
i
05 bar vert.
at filled cell
( we floor plan for location >
#5 bar Vert. w/
30" overlap
at each filled cell 4" concrete slab with fibermesh OR
I" recess for L"xL" #10/10 WWM on L mil Visqueen over
waterproofing at clean compacted termite treated fill
slab
L" base
Run stucco V below
bottom of block
Grade 4' >It slab bar at each fill cell
IIII „IIII ;IIII „IIII „IIII IIII IIII i IIII
F-16
Tuplcdl Section
Scale : 1/2" = 1'-0"
I I I
a
0
`m a
m �
I
I
I
I
I
I
I
I
I
I
I
I
II II II
I i
I I
J
TT p. Masonry Filled Cell Detail
NTS
Filled Cells
�(TypiceU
4 1/2"x 4 I/2"
Masonry Inspection
t Clean Out Hole
90" bend from footing
48 bar dia. lap in well
and footing
E
Dowel (I) #5 bar
w/ 25" min lap
and 6" embed
ate Footing
R-20 foam insulation
nts
Stucco retul
Section a Window
ttach window to block wall with
4" dia. x 3" tap —cons with min.
CD
1/2" penetration at 12" o.c. max
id 6" o.c. max from each corner thru
v1-
x 4" FT Buck
�
rywall return
z
O
N_
W
oc
arble sill
3
w
ul
QL
ywall
Q
J
a_
cc
u
ead $ Sill IM
NTS
a I
a
In
QO
C
Q-0U
u I
o'r
�
u
BUD
Q
Entegra Bella High "S" Roof Tile installed per product U
app,oval FLU: 1804.2 and evaluation report using
(2) IOd ring shank Halls over ppolyglass self adhered
roofing underlayment over 19/32" CDX plywood attached
to trusses per sheeting attachmen diagram on roof pi
N u-
PRE-EN INEERED RUSSES O
R—II foam insula ion at 4"o.c. TYP AL LL L ."
( shop dr ings by ma u acturer >
Simpson HTS 20 12 v U
hurricane anchor at each truss 6 Simpson HETA 20 1 dd
hurricane anchor at s U
( 2,4" o.c.) supporting Max. with (10) 10d x 1 1/2'
1450 Ibs, uplift (241805)lbspUplift
to
out beam as needed
5/8" drywall
Bthox I" x and finish with e r s s l X a ship l a p ceiling Q
i
stucco to match house u
Galy-Alum Metal drip on BI �+ p
1" x 4" Drip on I/2" thick stucco on 3/8" hi -rib lath
2'-O" attached to horizontal and vertical wood ( N
I" x B" Fascia framing with nails or staples to provide 2" x L" Sub -Fascia B3 no less than 1-3/1" penetration in o Q
horizontal wood framing and 3/4" p Prietr Q c C Q
into vertical wood framing members _ cc Y) �; Q
o) Q Ln oo ( Q
C N N U ()
4/ drywall ove� C 00 oo E
1/8" ig hat metal c annel strips at 14" o.c. with q 0 I I O Q
Strap Beam to column using Simpson R-43 celotex insulation/ fyf oil on � o rr � Q
MGT strap with (U 5/8" dia. ATR 8" concrete block OD � io #
embedded 12" min. in concrete and I N N 2
(22) 10d nails into wood beam (Duro-Rock is to be provided at
all wet areas. - ex. showers) 1Q U N v v
1/2"5/8 thick light concrete
textured L_ r r
attached
thick stucco on 3/e" hi -rib lath stucco on typical concr to M u W r r 1 �
attached to horizontal and vertical wood block construction IJJ ) N -, or -
framing with Hells or staples to provide �
no less than 1-3/4" penetration into
horizontal wood framing and 3/4" penetration Jc _ a
w L •� E IL
into vertical wood framing members
— 1
LL
W
R +'
ft5 bar Vert. In
12" dia concrete col. block at filled cell
filled w/ conc is ( see floor plan for location) LI.1
(3) #5 bars vert. 45 bar Vert. w/
30" overlap
at each filled cell 4" concrete slab with fibermesh OR
OxL" #10/10 WWM on L mil Visqueen over �.
clean compacted termite treated fill
O T-8 4" concrete slab with fibermesh OR 6" base
L"xb" #10/10 WWM on L mil Visqueen over
clean compacted termite treated fill
— — — — — Sheet
�=IIIIJUN "n"lSeetlon at i�ear fi or�.h rREC:EIVED
cr :oy, Permitting OFF—�f2 Scale : I/2" = I'—O" Comm u
18- 40
oaM sC�EDuLF.
Room Label
Flooring
Base
Wall Finish
Ceding Finish
Crown
clg. height
Ceding Notes
Foyer
Tile
6" wood
Light Textured Drywall
smooth finished drywall
Yes
10'-0i'
Great Room/Dining
Tile
6" wood
Light Textured Dr wall
I x 8 cypress ship lap
Yes
12 to 14
Breakfast
Tile
6" wood
Light Textured Drywall
smooth finished drywall
Yes
10'-O"
Kitchen
Tile
6" wood
Light Textured Drywall
smooth finished drywall
Yes
10'-0"
Master Bedroom
Wood
6" wood
Light Textured Dr wall
smooth finished drywall
Yes
10'-0"
Bedroom 42
Carpet
6" wood
Light Textured Drywall
smooth finished drywall
Yes
10'-O"
Bedroom 43
Carpet
6" wood
Light Textured Dr wall
smooth finished drywall
Yes
1O'-011
Bedroom #-{
Carpet
6" wood
Light Textured Drywall
smooth finished drywall
Yes
10'-0"
Master Bathroom
Tile
6" wood
Light Textured Drywall
smooth finished drywall
No
10'-O"
Bathroom #2
Tile
6" wood
Light Textured Drywall
smooth finished drywall
No
10'-on
Bathroom #3
Tile
6" wood
Light Textured Drywall
smooth finished drywall
No
10-01
Powder Room
Tile
6" wood
Light Textured Drywall
smooth finished drywall
No
10'-0"
Laundry Room
Tile
6" wood
Light Textured Drywall
smooth finished dr wall
No
10'-O"
Garage
Sealed Conc.
6" wood
Light Textured Drywall
Knock -down finished drywall
No
10'-6"
24"
Sir
hurricane
I
Strl
S P'
nail:
(.
ur
— - m
o
(1`
up
2" x
24° Stra
SP4I
It
nails
Elevation
INTERIOR FRAM
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
( shop drawings bg manufacturer )
Epson HTS 20
anchor at each truss
o.c.) supporting Max.
150 lbs. uplift
�(2) 2x4,
Top Plate
�p studs to plate using Simpson
strap with (I'.) IOd x 1 1/2"
in each strap
�) 2x4 SYP 42 studs �
)der each truss with a
X. spacing 24" o.c.
all studs together using (2)
0)d nails at 12" o.c, vert.
studs
4" blocking
2" x 4" bottom plate
w/ 1/2" dia. threaded
rods set in clean
predilled holes filled
w/ epoxy s 24" o.c.
Bolts to have min.
12" embedment
Into footing
p stud to plate using Simpson
strap with ((o) IOd x 1 1/2"--,
In each strap
�i
See foundation plan
for footing size and
steel req.
5/8" drywall telling
Underlayment notes:
- Contractor shall strictly follow these guidelines:
Underlayment design pressure for 140 mph Ultimate =
INFO.
PER PERMIT
BOX for Category II Buildings in Exposure B
with Importance factor
of 1.0 for roof with less than 112 sloe
_
TILE ATTACHMENT - use (2) IOd ring shank nails in each tile
AND Mortar system noted below.
PRODUCT
TEST
SPECIFICATIONS
PRODUCT
DESCRIPTION
Mortar Syg�stem
3M 2-component
2-09n.09
gg Patty placement
TO BE VED
Tile foam AH-140
of grams per the
Barrel Tile - see roof
plan, elevations, and
typ section for manufacturer
Contractor to adhere each Ede
per note in box above end I.A.W.
product approval from MFG
VIEW "C"
5/8" dia. threaded rods doweled min. 12"
Into column and set in epoxy
VIEW "All
fAfr
fi L,>4TE FLAN
4 3/e " .r. "N
BEAM 1"
ELT HEAC
THICKNE:
if0
p
_W
>
_W
>
1/2" thick plate
ALL THRUBOLTS TO BE
1/2" DIA. A325 STEEL
EEO-XX
VIEW "CH
5y„
-xx
V v 3
% 4/9' %" ALL FLANGES TO BE
I/2" THICK 50 KSI STEEL
VIEW "A"
FL,4NE FL,4N
VIEW "A" VIEW 1(13,f
VIEW
"CH VIEW "D"
F�E/4F� CCF�NEF,
COLUMN
C F
DET41L
ALL BOLTS TO BE A325 STEEL
ALL FLANGES AND PLATE TO BE 1/2" thick 5OKSI STEEL
Contractor to adhere each
per note in box above and
product approval from MFG
Self adhered underlayment
( see notes on roof plan )
19/32" CDX plywood
( see details for nailing )
Truss Tail
See details for construction
Anti -Pond ng
Gal,. Drip System
Roof Tile Installation Detail
nits
INSTALL TILES PER SYSTEM SHOWN
IN LOAD BOX
Contractor to adhere each the
y
per note in box above and I.A.W. Ridge Tile
Self adhered underlayment
product approval from MFG ( barrel ma be used )
see notes on roof plan )
Fasten ridge and hip
tiles on specified metal channels
19/32" roof sheeting
( see roof plan for attachment )
Barrel Tile Attachment Detail
nts
8/8" drywall on gypsum wallboard
both sides reinforce corner
18 gauge metal studs metal top track
bi—fold do,
4" concrete slab with flbermesh OR
(oIt
x6" 910/10 WWM on 6 mill Visqueen over
clean compacted termite treated fill
Typical baseboard
-c
o
'',c
c `..-o
'off-.'
3
—
Section
nts
-2"x4" Wood Buck
Note:
no track 8 bottom
of door, use fir.
bracket B pivot
,gypsum wallboard
_.reinforce corners
Metal channel attached to roof
\ with (1)3/4" Gov, screw at b" ox
Underlayment on 19/32" provided by East Coast Metals
CDX plywood
Concrete Tile Ridae Detail
nts
m wallboard
1/2" wood trim
.._,."—... ....... ....".. min. '2"x4" Wood Buck
MOO
Note:
all doors
to be prehung
Typical Interior Door Detal
"board
wood trim
)re —hung pocket door
s Ingle
NTS
NTsryplcal Pocket Door Detail
NTS
Owner specified
Coffer
- see section
C�IIIn
Simpson HTS-20 at each truss
truss with (24) IOd x 1 1/2" nails
in each strap
5/8" drywall Strap studs to plate using Simpson
ceiling SP4 strap with (6) IOd x 1 1/2"
nails in each strap
(2) 2" x 4" top plate
8" type "X" drywall on
gauge metal studs at 14" o.c.
D stall
Scale I/2"=1'-0"
Strap studs to plate using Simppson
SP4 strap with (6) IOd x I I/2"
nails in each strap
2" x 4" p.t. bottom plate with
1/2" anchor bolt at 32" o.c. and
min. 7 embedment with 2" washer
Typical baseboard 4" concrete slab with fibermesh OR
6"x4" #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
I
3 ap
R T
IL
0► I
c- t_ �
0
a3
v_
0
L-
t_
o
LL
r-
v0
U
C
-Ell
Q
j
J
(N
L
r Sheet
16"w x 16it concrete monolithic D
footingg with (2) tt5 bare cont.
and tt5 transverse bare at 32" o.c.
Typical Interior Searing Partition of 8
Scale: 1/2"
Comm #
18-40
Electrical S mbol Legend
S
Single Pole Switch
®
Recessed Can Light
S3
Double Pole Switch
®
Eyeball Recessed Can Light
SD
Dimmer Switch
Exhaust Pan
Pe
Push Button Switch
Ceiling Mounted Light
Duplex Outlet
Wall Mounted Light
=-G
Special Receptacle
ro
Light with Pull Chain (attic)
�
Waterproof, ground fault interrupts©
Computer Connection Jack
®
Floor Duplex Outlet
Flood Light
®
Junction Box
m
Electrical Panel
Q
Thermostat
8
Electrical Meter
®
Central Vac
A sc
A/C Disconnect
®
Smoke Detector
Ceiling Fan
©
Television Jack
aTelephone
Jack
®
2 x 4 Florescent Light
®
I I x 4 Florescent Light
intercom
®
Speaker Hook -Up
O
Ceiling Mounted Light Dome Style
+
Pendant Light
®
Motion Detector ( closet light )
©
Carbon Monoxide Detector
(2) #4 copper feed
(1) #4 copper feed
1#10 cu ground
2" PVC Conduit
2 CIR
S u B 200
PANEL ML
6OA
2" PVC ( ll
A/C disc.
PANEL
1ETER
(2) #2/0 copper feed
(1) 41/0 copper feed
#6 cu ground
2" PVC Conduit
#2 Copper
to FPL ug servic ground to rebar in slab
ELECTRICAL RISER
NTS
PANEL
"A„
Pates
BR
Load
Wire
Description
circ#
cec#
Description
Wire l
Load
BR
Poles
2
40
1.0 kw
#8
A/C comp
1
2
AHU
#10
3.5 kw
30
2
3
4
2
30
4.5 kw
#l0
40 gal. water HTR
5
L
Range
#L
12.0 kw
50
2
T
8
1
20
L6 kw
#12
Water Pump
9
10
Driler
#10
F.O kw
30
2
11
12
I
20
1.5 kw
#12
Range Hood
13
14
jr, pump
812
1.8 k#
20
2
1
20
1.2 kw
412
Clothes Washer
15
IL
1
20
.81 kw
#I2
Garage Door Opener
11
is
Dishwasher
#12
1.2 kw
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
19
20
Refrigerator
#12
1.2 kw
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
21
22
General Lighting
#12
20
1
1
20
$12
General Lighting
23
Z9
General Lighting
#12
-
20
I
-
1
20
#12
General Lighting
25
2L
General Lighting
#12
-
20
1
I
120
$12
General Lighting
21
28
General Lighting
#12
20
1
1
20
412
General Lighting
29
30
General Lighting
#12
-
20
1
-
1
20
#12
General Lighting
31
32
Bathroom GPI
#12
-
20
1
-
1
20
#12
General Lighting
33
34
Smoke Detectors
#10
2.8 kw
30
1
-
1
20
#12
General Lighting
35
36
Porch Refidgerator
1
20
#12
Bathroom GFI
3'1
38
Smoke Detectors
spare
39
40
spare
spare
41
42
spare
PANEL "A" LOAD CALCULATION SHEET
Load Description
Qty.
Watts
Total(Watte)
General Lighting (3 watts sq. ft)
Small. Appliance, Circuit(s),,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
Range ..
Range Hood .. ....... .......
Refrigerator.................................................
Dish Washer
......................................... I.............
Disposal ........ .......................................
Clothes.,Dryer................................................
Water Heater
.....I..............I........
Water, Pum..................... ...............................
Irrigation Pump ................................................
Porch Refrigerator
Wine Cooler
2598
3
1,194
2
1,500
3,000
1
5.000
5,000
I
I,100
1,100
1
1,200
1,200
1
1,200
1,200
1
1,000
1,000
5100
1,200
1
5,000
I
4,500
4.500
I
1,800
1,800
1
1,800
1,800
I
1,200
1,200
1
810
810
1
1,200
1,200
Total Watts
31,804
First 10000 Watts 9100%
1
10,000 10,000
Remainder 31,804 1140%
1
0 15,122
Electric Heat or A/C 10,000 045%
1
6,500 6,500
Calculated Load
Watts 31A22
Voltage 240
Calculated Wattage Divided bg Voltage = Total Amps 132
Panel Size Required = 20OAmps
riol
H
0 1�1 r-----------
0 1REF�
lug wr F 1 -4-----------"-\ I I
1 \\ I I
M STafr
I I CL03ET I
I----------
M AT R;; --- -�
\\ ,BEDROOM CEO
c
-
Pant 1 I I
Heat 1
® ;E1114TH 2\ I I So AN M
M14SZER
8 IT i BEDROOM 42�� 1 ��' BEDROOM #
GFCIII 4ID !II\ nt ITVI
Interior Bearing Wall
JhP� = C Interior Bearing Wall C
/ I 1471 ----- -- / 1471 I I
I J� - 7
/ I I
\
\ °\ GREAT ROOM ®, M ; DINING ROOIIM ,
- \ Locnte 6y Owner -� _ -%a tiy-y
--------------
qp
` - sc
.11
------------
GFCI / /
A � I
c /bove
�i IFSI--- / t Bel FANCabne was Lights I F O R / I
J o 1
KITCHEN \\ I
:E)- AUNDRY I
C
AKFAST ®-------Ei ------- WASHER LIBRARY I
NOOK
IIFIK*C�1 FCI- GFCI II ---`-
2"
ELEC7RICAL FLAN
ELECTRIC NOTES: 'SCALE:
1/4" = 1'-0"
I.
Use copper wire only, no aluminum.
2.
Provide and wlre all required smoke detectors.
3.
Contractor to verify location of electrical service and provider
4.
.ALL paddle fans shall be on a rheostat.
S.
Recessed cans to be Installed per NFPA requirements.
L
ALL Branch Circuits that supply 125v single phase 15 amp or 20 amp outlets
shall be protected by Combination -Type AFCI Circuit Breakers.
7.
Tamper resistant AFCI receptacles to be Installed in ALL rooms
Kitchen, Bathrooms, and Garage.
8.
ALL bath and kitchen and garage receptacles to be GFCI protected.
q.
ALL exterior outlets to be LUP/GFCI protected.
10.
A/C Return Air Balance Must comply w/ F.B.C. Mechanical 2010 ed.
and
current version of any supplements to the 2010 ed.
II.
,A/C Refrigerant Imes that are run thru slabs must be sleeved in PVC
12.
ALL A/C Equipment shall be 16 SEER
13.
Provide Disconnects at ALL appliances (water heater, A/C units, and
ALL other equipment as required by N.E.C.)
14.
A/C Ducts In Garage shall be metal or I" thick minimum rigid nonmetallic
Class 0 or
Class I duct or other approved material and shall have no openings into
the garage.
15.
Smoke Alarms shall be Installed in the following locations:
a) In each sleeping room.
b) Outside each separate sleeping area in the immediate vicinity of the
bedrooms.
On each additional story of the dwelling
** ALL Smoke Alarms shall be interconnected and hardwired **
78,_4„
' Eell�
r� i \ •
r . -
iiinterioF Bearing Wall
w��•ar�.s;;e��dsxe � aseys�•ywaerr_r�tia-�•aar, i,�_ -
� 111
Or---------
A.H.U.
Id1Us
GFCI
' i. us
�\
PC
I
I \
PCi
I
1
©
I
i Garage
I
I Door
I Opener
entral Vac
GFCI
/
/
I
I
I
I
I
I
I
I
I
I
1
I
ostl
post
W.H. wh
guard
GP
GFCI
AC01 C 'P GFCI
2' U.C.Vent
JL
I
LAV-I
KITCHEN
2"
2
\ 2"
3' VTR
12"
FOWDER
SINK-]
12
12
[ OOM
2"
I
I 2n
LAV-1
2
I SINK-1
i
Lrl
BA T H
TT�
2
\\
2„
wM..l
2„
2„
we -I
i
I I2
3
GFCI
Photo Sensor
hoto Sensor
2' U.C.Vent
ALFORCH
12"
3' VTR
SINK -I 1 �I
fi\ MASTER
r\- 2' 3„1 \\BATH BATH 92
2
12„ 1 WC-1 T
1 LAv-1 I 2" BT J I \\\ 3
2 1 LAv-1 3„ 12 LAVJ i 3„
2„ 3„ eT '
2„ 3„ we-i1
LAUNDRY 12,� 13Ava
3° I'' GARAGE
SANITARY RISER
2"
BT-I
2„
a
COnneCt t0
sewer line
nts
3 OD
0 0
IN
a
U
0
U 0
0
W
0
Q
C
v
C
Q
Q to OD
n3
� CY CV
OD 00
U
E
�(L
g I 1
o�Mta
G
p6CV
Re,UN(-4
1
Uj
t! y ..
mar
`
E
V- �
w
v4
Sheet
E
OF 8
Comm #
18-�'O