HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNED
FORM R405-2017 By
FLORIDA ENERG pPrd#_1V&, CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
l
Project Name: Lot3lTarpon FlatsModelBGr I
Builder Name: FHOEqIX REALTY HOMES
Street: 3910 DUNE SIDE DRIVE
Permit Office: N
City, State, FORT PIERCE, FL,
Permit Number:
Owner.
Jurisdiction: 661000
Design Location: FL, Fort Pierce
I
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans) �I
9. Wall Types (3182.7 sgft)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 2954.00 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
c. N/A
R=13.0 228.67 ft2
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No 'i
10. Ceiling Types (1959.0 sgft)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 1959.00 ft2
6. Conditioned floor area above grade (ft2) 2632
b. N/A
R= ft2
Conditioned floor area below grade (W) 0 I
c. N/A
R= ft2
7. Windows(540.0 sgft) Description Area
I
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R f:2
6 383.8
a. U-Factor: Dbl, U=0.36 396.04 ft2
b. Sup: Attic, Ret: Attic, AH: Attic
6 142.6
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=1.02 144.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
46.0 SEER:14.00
c. U-Factor: N/A ft2
I
b. Central Unit
22.2 SEER:14.50
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
45.5 HSPF:8.20
SHGC:
b. Electric Heat Pump
22.2 HSPF:8.20
Area Weighted Average Overhang Depth: 6.662 ft.
Area Weighted Average SHGC: 0.300
14. Hot water systems
8. Floor Types (2632.0 sgft) Insulation Area
a. Electric
Cap: 80 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1919.00 ft2
b. Conservation features
EF: 3.700
b. Floor Over Other Space R=0.0 713.00 ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 87.81
Glass/Floor Area: 0.205
Total Baseline Loads:
C
PASS
90.40
I
I hereby certify that the plans and specifications covered by
Rleview of the plans and
ktE SrA`,,
this calculation are in coVanith the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
PREPARED BY:
with the Florida Energy Code.
Before construction is completed
DATE: R-14-1A Adam K Rhopirlq
this building will be inspected for
compliance with Section 553.908
hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy goe.
OWNER/AG
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1. I
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.06 ACH50 (R402.4.1.2).
I
File C®iny
6/14/2018 9:11 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6
i
1�FORM R405-2017
(PROJECT
Title:
Lot3l Tarpon FlatsModel BG r Bedrooms: 3
Address Ty e:
Street Address
Building Type:
Owner Name:
er 2
/�LL�
Conditioned Area: 2632
Total Stories: 2
Lot # v C /D
Block/Subdivision:
# of Units:
l/
1
Worst Case: No
PlatBook: OZ
Builder Name:
PHOENIX REALTY
HOMES Rotate Angle: 1, 0
Street:
3910 DUNE SIDE DRIV
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
FORT PIERCE,
Family Type:.
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CdMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299
62 Low
BLOCKS
1
Number
Name
Area Volume
1
Blockl
1919 17846.7
2
Block2
713 6630.9
SPACES
1
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
1st Floor
1919 17846.7 Yes 4
1
1 Yes
Yes Yes
2
2nd Floor
713 6630.9 No 0
2
1 Yes
Yes Yes
FLOORS I
#
Floor Type
Space Perimeter Perimeter1R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio 1st Floor 194.5 ft 0
1919 ft2
___
0.42 0 0.58
2 Floor Over Other Space
2nd Floor _-_ __
713 ft2
0
0.1 0 0.9
ROOF
/
Roof Gable
Solar
SA Emitt
Emitt Deck Pitch
�/ #
Type
-joof
Materials Area Area Color
Absor.
Tested
Tested Insul. (deg)
1
Gable or Shed
Metal 2146 ft2 480 ft2 Medium
0.75
N 0.75
No 20 26.6
ATTIC
1j
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
No attic
Unvented 0 II1919 ft2
N N
6/14/2018 9:11 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1
I
i
Compliant Software
I
Page 2 of 5
FORM R405-2017
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic (Unvented) 1st Floor 0 Batt 1152 ft2 0.11 Wood
2 Under Attic (Unvented) 2nd Floor 0 Batt 807 ft2 0.11 Wood
Adjacent
10
Space
Wall lypeRAW,
Cavity
Width
Ft In
-
Et
Height
In
Area
Sheathing Framing
R-Ntalue Frnctmon
Solar
Ab-or-
Below
rrgrip%
1
N
Exterior
Concrete Block - Int Insul 1st Floor
4.1
*11
6 9
4
471.3 ft2
0
0
0.6
0
2
N
Exterior
Concrete Block - Int Insul2nd Floor
4.1
29
0 9
4
270.7 ft2
0
0
0.6
0
3
E
Exterior
Concrete Block- Int Insul 1st Floor
4.1
16
0 9
4
149.3 ft2
0
0
0.6
0
4
E
Exterior
Concrete Block - Int Insul2nd Floor
4.1
27
0 9
4
252.0 ft2
0
0
0.6
0
5
S
Exterior
Concrete Block - Int Insul 1st Floor
4.1
47
0 9
4
438.7 ft2
0
0
0.6
0
6
S
Exterior
Concrete Block - Int Insul2nd Floor
4.1
34
0 9
4
317.3 ft2
0
0
0.6
0
7
W
Exterior
Concrete Block - Int Insul 1st Floor
4.1
30
0 9
4
280.0 ft2
0
0
0.6
0
8
W
Exterior
Concrete Block - Int Insul2nd Floor
4.1
20
0 9
4
186.7 ft2
0
0
0.6
0
9
-
Garage
Frame - Wood 1st Floor
13
24
6 9
4
228.7 ft2
0
0.23
0.01
0
10
E
Exterior
Concrete Block - Int Insul 1st Floor
4.1
27
0 '9
4
252.0 ft2
0
0
0.6
0
_ 11
E
Exterior
Concrete Block - Int Insul 1st Floor
4.1
16
0 9
4
149.3 ft2
0
0
0.6
0
12
W
Exterior
Concrete Block - Int Insul 1st Floor
4.1
8
0 9
4
74.7 ft2
0
0
0.6
0
13
N
Exterior
Concrete Block - Int Insul2nd Floor
4.1
5
0 9
4
46.7 ft2
0
0
0.6
0
14
W
Exterior
Concrete Block - Int Insul2nd Floor
4.1
7
0 9
4
65.3 ft2
0
0
0.6
0
# Omt Door Type Space I Storms U-Value Width Height Area
Ft In Ft In
1 W Wood 1st Floor None .25 3 8 24 ft2
2 - Wood 1st Floor None .25 2 8 8 21.3 ft2
WINDOWS
Orientation shown is the entered Proposed orientation.
/
Wall
Overhang
V #
Omt
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N
13
Vinyl
Low-E Double
Yes
0.36
0.3
I N
14.0 ft2
9 ft 7 in
0 ft 4 in
Drapes/blinds
Exterior 5
2
N
2
Vinyl
Low-E Double
Yes
0.36
0.3
I N
6.3 ft2
2 ft 3 in
0 ft 4 in
Drapes/blinds
None
3
E
10
Metal
Low-E Double
Yes
1.02
0.3
i N
144.0 ft2
11 ft 3 in
0 ft 4 in
None
None
4
E
3
Vinyl
Low-E Double
Yes
0.36
0.3
N
33.8 ft2
2 ft 3 in
0 ft 4 in
None
Exterior 5
5
E
11
Vinyl
Low-E Double
Yes
0.36
0.3
N
33.8 ft2
14 ft 5 in
0 ft 4 in
None
Exterior 5
6
E
3
Vinyl
Low-E Double
Yes
0.36
0.3
N
31.7 ft2
2 ft 3 in
0 ft 4 in
None
None
7
E
11
Vinyl
Low-E Double
Yes
0.36
0.3
N
31.7 ft2
14 ft 5 in
0 ft 4 in
None
None
8
E
4
Vinyl
Low-E Double
Yes
0.36
0.3
N
64.8 ft2
2 ft 3 in
0 ft 4 in
None
Exterior 5
9
S
5
Vinyl
Low-E Double
Yes
0.36
0.3
N
22.2 ft2
2 ft 3 in
0 ft 4 in
None
Exterior 5
10
S
6
Vinyl
Low-E Double
Yes
0.36
0.3
N
4.0 ft2
2 ft 3 in
0 ft 4 in
None
None
11
W
7
Vinyl
Low-E Double
Yes
0.36
0.3
N
33.8 ft2
2 ft 3 in
11 ft 8 in
None
Exterior 5
12
W
7
Vinyl
Low-E Double
Yes
0.36
0.3
N
33.8 ft2
2 ft 3 in
0 ft 4 in
None
Exterior 5
13
W
12
Vinyl
Low-E Double
Yes
0.36
0.3
N
1
12.0 ft2
6 ft 3 in
0 ft 4 in
None
None
14
W
8
Vinyl
Low-E Double
Yes
0.36
0.3
N
14.0 ft2
I
2 ft 3 in
0 ft 4 in
Drapes/blinds
Exterior 5
6/14/2018 9:11 AM
EnergyGauge® USA - FlaRes2017
Section R405.4.1
Compliant Software
Page 3 of 5
FORM R405-2017
WINDOWS
Orientation shown is the entered, Proposed orientation.
#
Wall
Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
15
16
W 8 Vinyl Low-E Double Yes
W 14 Vinyl Low-E Double Yes
0:36 0.3 N 32.4 ft2 2 ft 3 in 0 ft 4 in Drapes/blinds
0.36 0.3 N 28.0 ft2 7 ft 3 in 0 ft 4 in Drapestblinds
Exterior 5
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
492 ft2
492 ft2
164 ft 8 ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000355
2447.8 I134.38 252.72 .3187 6
HEATING�SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
2
Electric Heat Pump/
Electric Heat Pump/
Split
Split
HSPF:8.2000 45.5 kBtu/hr 1
HSPF:8.2000 22.2 kBtu/hr 2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
I Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit/
Central Unitt
Split
Split
SEER: 14 46 kBtu/hr cfm 0.75 1
'SEER: 14.5 22.2 kBtu/hr cfm 0.75 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric Heat Pump
Garage
3.7 80 gal 66.6 gal 120 deg None
SOLAR HOT WATER SYSTEM
I
FSEC
Cart # Company Name
Collector Storage
System Model # Collector Model # Area Volume FEF
None None
I ft2
DUCTS
/
#
-- Supply ---
Location R-Value Area
-- Return---- Air CFM 25 CFM25 HVAC #
Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1
2
Attic 6 383.8 ft
Attic 6 142.6 ft
Attic
Attic
95.95 ft Default Leakage Attic (Default) (Default)
35.65 ft Default Leakage Attic (Default) (Default)
1 1
2 2
6/14/2018 9:11 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
TEMPERATURES
1
Programable Thermostat: Y
Ceiling Fans:
Cooling [ ] Jan
Heatin(j Jan
((]] Feb
[X] Feb
[[ ]]Mar
[X] Mar
[ ] A r
[ ) APr
May Jun rl Jul
JunJul
May�Xl
[XI Au
Au
Se
Sep
rl
[ ]
[ ]
W
Oct
Oct
Nov
Nov f
HX
Dec
X� Dec
Ventin [ ]1J11 Jan
[) Feb
[X]) Mar
[X] A r
[
Ma Jun Jul
EAug
Se
Oct
Nov [
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
MECHANICAL VENTILATION
1
Type
Supply CFM
Exhaust CFM
Fan Watts HRV Heating System
Run Time
Cooling System
Runtime Vent
58
0
0 1 - Electric Heat Pump
%
1 - Central Unit
6/14/2018 9:11 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1
Compliant Software
Page 5 of 5
I
FORM R405-2017
ENERGY PERFORMANCE LEVEL
(EPL)
DISPLAY CARD
I
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformiance Index, the more efficient the home.
3910 DUNE SIDE DRIVE, FORT PIERCE, FL,
1. New construction or existing New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1
2954.00 ft2
b. Frame - Wood, Adjacent
R=13.0
228.67 ft2
3. Number of units, if multiple family 1 c. N/A
R=
ft2
4. Number of Bedrooms 3 d. N/A
R=
ft2
5. Is this a worst case? No 10. Ceiling Types
Insulation
Area
a. Roof Deck (Unvented)
R=20.0
1959.00 ft2
6. Conditioned floor area (ft2) b. b. N/A
it
R=
ft2
c. N/A
7. Windows" Description Area
R=
ft2
11. Ducts
a. U-Factor: Dbl, U=0.36 396.04 ft2 a. Sup: Attic, Ret: Attic, AH: Attic
R ft2
6 383.8
SHGC: SHGC=0.30 b. Sup: Attic, Ret: Attic, AH: Attic
6 142.6
b. U-Factor: Dbl, U=1.02 144.00 ft2
SHGC: SHGC=0.30 I 12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A ft2 a. Central Unit
46.0 SEER:14.00
l
SHGC: b. Central Unit
22.2 SEER:14.50
d. U-Factor: N/A ft2 13. Heating systems
kBtu/hr
Efficiency
SHGC: a. Electric Heat Pump
45.5
HSPF:8.20
Area Weighted Average Overhang Depth: 6.662 f . b. Electric Heat Pump
I
22.2
HSPF:8.20
Area Weighted Average SHGC: 0.300
8. Floor Types Insulation Area 14. Hot water systems
I
Cap:
80 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1919.00 ft2 a. Electric
EF: 3.7
b. Floor Over Other Space R=0.0 713.00 ft2
I
c. N/A R= ft2 b. Conservation features
i None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. I.
Builder Signature: Dated '
Address of New Home: fQ �GL�=G�G�i i City/FL Zip: �77
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge, Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/14/2018 9:11 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
I