Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNED FORM R405-2017 By FLORIDA ENERG pPrd#_1V&, CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method l Project Name: Lot3lTarpon FlatsModelBGr I Builder Name: FHOEqIX REALTY HOMES Street: 3910 DUNE SIDE DRIVE Permit Office: N City, State, FORT PIERCE, FL, Permit Number: Owner. Jurisdiction: 661000 Design Location: FL, Fort Pierce I County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) �I 9. Wall Types (3182.7 sgft) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 2954.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent c. N/A R=13.0 228.67 ft2 R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 'i 10. Ceiling Types (1959.0 sgft) Insulation Area a. Roof Deck (Unvented) R=20.0 1959.00 ft2 6. Conditioned floor area above grade (ft2) 2632 b. N/A R= ft2 Conditioned floor area below grade (W) 0 I c. N/A R= ft2 7. Windows(540.0 sgft) Description Area I 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R f:2 6 383.8 a. U-Factor: Dbl, U=0.36 396.04 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 142.6 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=1.02 144.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 46.0 SEER:14.00 c. U-Factor: N/A ft2 I b. Central Unit 22.2 SEER:14.50 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 45.5 HSPF:8.20 SHGC: b. Electric Heat Pump 22.2 HSPF:8.20 Area Weighted Average Overhang Depth: 6.662 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems 8. Floor Types (2632.0 sgft) Insulation Area a. Electric Cap: 80 gallons a. Slab -On -Grade Edge Insulation R=0.0 1919.00 ft2 b. Conservation features EF: 3.700 b. Floor Over Other Space R=0.0 713.00 ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 87.81 Glass/Floor Area: 0.205 Total Baseline Loads: C PASS 90.40 I I hereby certify that the plans and specifications covered by Rleview of the plans and ktE SrA`,, this calculation are in coVanith the Florida Energy specifications covered by this Code. calculation indicates compliance PREPARED BY: with the Florida Energy Code. Before construction is completed DATE: R-14-1A Adam K Rhopirlq this building will be inspected for compliance with Section 553.908 hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy goe. OWNER/AG BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. I - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.06 ACH50 (R402.4.1.2). I File C®iny 6/14/2018 9:11 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6 i 1�FORM R405-2017 (PROJECT Title: Lot3l Tarpon FlatsModel BG r Bedrooms: 3 Address Ty e: Street Address Building Type: Owner Name: er 2 /�LL� Conditioned Area: 2632 Total Stories: 2 Lot # v C /D Block/Subdivision: # of Units: l/ 1 Worst Case: No PlatBook: OZ Builder Name: PHOENIX REALTY HOMES Rotate Angle: 1, 0 Street: 3910 DUNE SIDE DRIV Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type:. Single-family FL, New/Existing: New (From Plans) Comment: CdMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS 1 Number Name Area Volume 1 Blockl 1919 17846.7 2 Block2 713 6630.9 SPACES 1 Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st Floor 1919 17846.7 Yes 4 1 1 Yes Yes Yes 2 2nd Floor 713 6630.9 No 0 2 1 Yes Yes Yes FLOORS I # Floor Type Space Perimeter Perimeter1R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio 1st Floor 194.5 ft 0 1919 ft2 ___ 0.42 0 0.58 2 Floor Over Other Space 2nd Floor _-_ __ 713 ft2 0 0.1 0 0.9 ROOF / Roof Gable Solar SA Emitt Emitt Deck Pitch �/ # Type -joof Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 2146 ft2 480 ft2 Medium 0.75 N 0.75 No 20 26.6 ATTIC 1j V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 No attic Unvented 0 II1919 ft2 N N 6/14/2018 9:11 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 I i Compliant Software I Page 2 of 5 FORM R405-2017 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) 1st Floor 0 Batt 1152 ft2 0.11 Wood 2 Under Attic (Unvented) 2nd Floor 0 Batt 807 ft2 0.11 Wood Adjacent 10 Space Wall lypeRAW, Cavity Width Ft In - Et Height In Area Sheathing Framing R-Ntalue Frnctmon Solar Ab-or- Below rrgrip% 1 N Exterior Concrete Block - Int Insul 1st Floor 4.1 *11 6 9 4 471.3 ft2 0 0 0.6 0 2 N Exterior Concrete Block - Int Insul2nd Floor 4.1 29 0 9 4 270.7 ft2 0 0 0.6 0 3 E Exterior Concrete Block- Int Insul 1st Floor 4.1 16 0 9 4 149.3 ft2 0 0 0.6 0 4 E Exterior Concrete Block - Int Insul2nd Floor 4.1 27 0 9 4 252.0 ft2 0 0 0.6 0 5 S Exterior Concrete Block - Int Insul 1st Floor 4.1 47 0 9 4 438.7 ft2 0 0 0.6 0 6 S Exterior Concrete Block - Int Insul2nd Floor 4.1 34 0 9 4 317.3 ft2 0 0 0.6 0 7 W Exterior Concrete Block - Int Insul 1st Floor 4.1 30 0 9 4 280.0 ft2 0 0 0.6 0 8 W Exterior Concrete Block - Int Insul2nd Floor 4.1 20 0 9 4 186.7 ft2 0 0 0.6 0 9 - Garage Frame - Wood 1st Floor 13 24 6 9 4 228.7 ft2 0 0.23 0.01 0 10 E Exterior Concrete Block - Int Insul 1st Floor 4.1 27 0 '9 4 252.0 ft2 0 0 0.6 0 _ 11 E Exterior Concrete Block - Int Insul 1st Floor 4.1 16 0 9 4 149.3 ft2 0 0 0.6 0 12 W Exterior Concrete Block - Int Insul 1st Floor 4.1 8 0 9 4 74.7 ft2 0 0 0.6 0 13 N Exterior Concrete Block - Int Insul2nd Floor 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 14 W Exterior Concrete Block - Int Insul2nd Floor 4.1 7 0 9 4 65.3 ft2 0 0 0.6 0 # Omt Door Type Space I Storms U-Value Width Height Area Ft In Ft In 1 W Wood 1st Floor None .25 3 8 24 ft2 2 - Wood 1st Floor None .25 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 13 Vinyl Low-E Double Yes 0.36 0.3 I N 14.0 ft2 9 ft 7 in 0 ft 4 in Drapes/blinds Exterior 5 2 N 2 Vinyl Low-E Double Yes 0.36 0.3 I N 6.3 ft2 2 ft 3 in 0 ft 4 in Drapes/blinds None 3 E 10 Metal Low-E Double Yes 1.02 0.3 i N 144.0 ft2 11 ft 3 in 0 ft 4 in None None 4 E 3 Vinyl Low-E Double Yes 0.36 0.3 N 33.8 ft2 2 ft 3 in 0 ft 4 in None Exterior 5 5 E 11 Vinyl Low-E Double Yes 0.36 0.3 N 33.8 ft2 14 ft 5 in 0 ft 4 in None Exterior 5 6 E 3 Vinyl Low-E Double Yes 0.36 0.3 N 31.7 ft2 2 ft 3 in 0 ft 4 in None None 7 E 11 Vinyl Low-E Double Yes 0.36 0.3 N 31.7 ft2 14 ft 5 in 0 ft 4 in None None 8 E 4 Vinyl Low-E Double Yes 0.36 0.3 N 64.8 ft2 2 ft 3 in 0 ft 4 in None Exterior 5 9 S 5 Vinyl Low-E Double Yes 0.36 0.3 N 22.2 ft2 2 ft 3 in 0 ft 4 in None Exterior 5 10 S 6 Vinyl Low-E Double Yes 0.36 0.3 N 4.0 ft2 2 ft 3 in 0 ft 4 in None None 11 W 7 Vinyl Low-E Double Yes 0.36 0.3 N 33.8 ft2 2 ft 3 in 11 ft 8 in None Exterior 5 12 W 7 Vinyl Low-E Double Yes 0.36 0.3 N 33.8 ft2 2 ft 3 in 0 ft 4 in None Exterior 5 13 W 12 Vinyl Low-E Double Yes 0.36 0.3 N 1 12.0 ft2 6 ft 3 in 0 ft 4 in None None 14 W 8 Vinyl Low-E Double Yes 0.36 0.3 N 14.0 ft2 I 2 ft 3 in 0 ft 4 in Drapes/blinds Exterior 5 6/14/2018 9:11 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 WINDOWS Orientation shown is the entered, Proposed orientation. # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 15 16 W 8 Vinyl Low-E Double Yes W 14 Vinyl Low-E Double Yes 0:36 0.3 N 32.4 ft2 2 ft 3 in 0 ft 4 in Drapes/blinds 0.36 0.3 N 28.0 ft2 7 ft 3 in 0 ft 4 in Drapestblinds Exterior 5 Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 492 ft2 492 ft2 164 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000355 2447.8 I134.38 252.72 .3187 6 HEATING�SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Heat Pump/ Electric Heat Pump/ Split Split HSPF:8.2000 45.5 kBtu/hr 1 HSPF:8.2000 22.2 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype I Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unitt Split Split SEER: 14 46 kBtu/hr cfm 0.75 1 'SEER: 14.5 22.2 kBtu/hr cfm 0.75 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Heat Pump Garage 3.7 80 gal 66.6 gal 120 deg None SOLAR HOT WATER SYSTEM I FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None I ft2 DUCTS / # -- Supply --- Location R-Value Area -- Return---- Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 2 Attic 6 383.8 ft Attic 6 142.6 ft Attic Attic 95.95 ft Default Leakage Attic (Default) (Default) 35.65 ft Default Leakage Attic (Default) (Default) 1 1 2 2 6/14/2018 9:11 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 TEMPERATURES 1 Programable Thermostat: Y Ceiling Fans: Cooling [ ] Jan Heatin(j Jan ((]] Feb [X] Feb [[ ]]Mar [X] Mar [ ] A r [ ) APr May Jun rl Jul JunJul May�Xl [XI Au Au Se Sep rl [ ] [ ] W Oct Oct Nov Nov f HX Dec X� Dec Ventin [ ]1J11 Jan [) Feb [X]) Mar [X] A r [ Ma Jun Jul EAug Se Oct Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION 1 Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System Runtime Vent 58 0 0 1 - Electric Heat Pump % 1 - Central Unit 6/14/2018 9:11 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 I FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD I ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformiance Index, the more efficient the home. 3910 DUNE SIDE DRIVE, FORT PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 2954.00 ft2 b. Frame - Wood, Adjacent R=13.0 228.67 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types Insulation Area a. Roof Deck (Unvented) R=20.0 1959.00 ft2 6. Conditioned floor area (ft2) b. b. N/A it R= ft2 c. N/A 7. Windows" Description Area R= ft2 11. Ducts a. U-Factor: Dbl, U=0.36 396.04 ft2 a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 383.8 SHGC: SHGC=0.30 b. Sup: Attic, Ret: Attic, AH: Attic 6 142.6 b. U-Factor: Dbl, U=1.02 144.00 ft2 SHGC: SHGC=0.30 I 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 46.0 SEER:14.00 l SHGC: b. Central Unit 22.2 SEER:14.50 d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 45.5 HSPF:8.20 Area Weighted Average Overhang Depth: 6.662 f . b. Electric Heat Pump I 22.2 HSPF:8.20 Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14. Hot water systems I Cap: 80 gallons a. Slab -On -Grade Edge Insulation R=0.0 1919.00 ft2 a. Electric EF: 3.7 b. Floor Over Other Space R=0.0 713.00 ft2 I c. N/A R= ft2 b. Conservation features i None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. I. Builder Signature: Dated ' Address of New Home: fQ �GL�=G�G�i i City/FL Zip: �77 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge, Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/14/2018 9:11 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 I