Loading...
HomeMy WebLinkAboutLETTER MECHANICAL CALCULATIONSRECEIVED AMD 913 DEL=AIR JAN 2 2 2020 ! HEATING • AIR CONDITIONING ®�� e ii ST. Lucie County, Permitting December 20; 2019 ATTN: St. Lucie County, FLIDept. of Building & Code Regulation Division RE: Phoenix Homes Realty Inc. - Lot 31 Tarpon Flats The mechanical ventilation calculations as required by 2017 FBC Mechanical, 61h Edition Chapter 401.2 for Lot 31 Tarpon Flats are designed per code and shall follow these parameters as described as proposed in the 2017 FBC — Energy Conservation, 6th Edition Chapter 4, not to exceed .01 x CFA + 7.5 x(Number of Bedrooms +1): Living Square Footage: 2632 Number of Bedrooms: 3 +1 = 4 .01 x 2632 = 26.32 4x7.5=30 I 26.32 + 30 = 56.32 CFM This method is also within compl lance with the simplified 2017 FBC M1507.3.3(1) Chart as listed below: DWELLING UNIT FLOOR AREA (square feet) NUMBER OF BEDROOMS 0-12-34-56-7}7 Airflow in CFM < 1,500 30 45 1 60 1 75 90 1,561— 3,000 45 6(1) 1 75 00 105 3,001— 4,500 60 75 90 105 120 4,501 — 6,000 75 90 105 120 135 6,001— 7,500 90 105 120 135 150 > 7,590 105 120 135 150 165 I Del -Air designed and installed a 6" diameter fresh air ventilation intake including mechanical damper, control, and shut off to handle code mechanical ventilation requirement, when a residential building's envelope tests below 3ACH50. Sincerely, Corpbrate Headquarters 5311 Codisco Way Sanford, Florida 32771 Statewide (888) 831-COOL (2665) Fax'.,(407) 333-3853 State Lic. CAC032448 M F H",JLETT e3uvilx-onnuental �Serviices www,bugs.com Owner Lot Sub-Divison StreetAddress city General Contractor Sub Contractor 31 3910 Duneside Dr Hutchinson Island, FL Structural Building Cc Comments ACCOUNT #820212 final During the term of your service agreemen (including Formosan Termites) will be perfor see details on subterranean termite service Reticulitermes virginicus, Reticulitermes ht Coptotermes gestroi-Asian Termite) excludi Services. Hulett Environmental Services wi term shall be one (1) year from the initial d agreement annually (after the first year) for with Mment of annual renewal fee. Please Your agreement covers all materials, labor, I infestation of subterranean termites incIr agreement holder can request consultation a pests at no additional charge. This service owner should the property be sold. Hulett Er in writing of new ownership of the property. deductible. Should you require any addit termite renewal department. This building I the prevention of subterranean termites. Trel laws established by the Florida Department c CERTIMCATIONSIGNED Radio Dispatched ALI1.`24-Hour. Service" Corporate Center P.O. Box 220928, West Palm Beach, FL 33422-0928 1-800-285-PEST (7378) Block Bldg,# 511 JAN 2 2 2020 12Date 18/2019 ST. Lucie County, Permitting any further treatment necessary due to infestation of subterranean termites ed free of charge. Any structural damage necessitating repairs (up to $1,000,000, reement) that is caused by the subterranean termites (Reticulitermes flavipes, eni, Prohinotermes simplex, Coptotermes formosanus-Formosan Termite and Nasutitermes costalis (Tree Termite) will be paid for by Hulett Environmental annually reinspect the property only at your request. The service agreement of treatment. The homeowner sball have the option of extending the service D less than four (4). additional years Intact our office for further details. I service needed to control an active rig Formosan Termites. A service :...:! ` •.? advice concerning termites or other ;`ail di';! .1 t•-; :.� . '...,,;. �� :.'; •;,-�> ;.I . reement is transferable to the new = :'fi':r=, '' i` "'"��, •:, bnmental Services must be notified ;�,'':;..•; `.': °'� ;:. fur service agreement:has a $0.00 :- ''•' ' i•, . . ! ial information I ease contact our r::`• •.!'� `;•x,: ' '' ' • T received a complete treatment for rent is in accordance with rules and ►gr_Wulture and Consumer Services. gs.com ®Hales Environmental SeMomb 2019 TMS-PT002 12019 Rox 3