HomeMy WebLinkAboutSOIL NUCLEAR GAUGE. I (�, a sr" -- 0 1 -7 � Au1100 eM &S Soil Nuclear Gauge Client: Project: As Report Date: 7/13/2018 Phoenix Realty Homes, Inc. 17-0495.00 �.Yw,�HAnONP" (13I V I V V OS Test Method: ASTM D 6938 1760 North Jog Road, Suite 120 Phoenix Realty Homes - Various Locations PortSt Lucie West Palm Beach, FL 33411 FBPE CA # 4930 ' 607 NW Commodity Cove Port SL Lucie. FL 34986 Phone: 772-924-3575 1 Fax: 772-924-3580 Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pc In Place Moisture (%) In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. (°/,) Remark 24 6120118 7921 - D1557 N/A 10.5 118.3 9.9 114.3 12 97 95 / 105 Pass 25 6120/18 7921 - D1557 N/A 10.5 118.3 9.7 114.3 12 97 95 / 105 Pass 26 1 1 6/20/18 1 7921 - D1557 N/A 10.5 1 118.3 1 9.8 1 114.2 12 1 97 1 95 / 105 1 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model I SN I Calibrated Field Technician 24 Above Stripped Surface: Tarpon Flats, Lot 31, NW corner of pad 0-1 Troxler / 3430 / 24566/ Presson, Thomas 25 Above Stripped Surface: Tarpon Flats, Lot 31, Center of pad 0-1 Troxler 13430 / 24566 / Presson, Thomas 26 Above Stripped Surface: Tarpon Flats, Lot 31, SE comer of pad 0-1 Troxler 13430 / 24566 / Presson, Thomas Remarks Comments _ _ _� RECE1 — ---- — -- Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 24, 25, 26: 1-2 HCP=40+. > 95 % Compaction, PASS. HCP tests are empirically correlated to the relative density of the soil. \�,�11111l►,/�/ •���p\AN K4 Nlv � .�,1GENgF' PERMIT # 18050179 632,18 Er- �9 I<enf, P.E. rgAA0ion§T1" iee(* 3218 a ZONAL 0���•\• VED JUL 13 2010 Permitting Department St. Lucie County Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Page 1 of 1 Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 0 Port St. Lucie FBPE CA A 4930 607 NW Commodity Cove Port St Lucie, FL 34988 Phone: 772.924-35751 Fax: 72-924-3580 Soil Nuclear Gauge Report Date: 7/16/2018 Test Method: ASTM D 6938 Client: Project: /�'O--0/71 Phoenix Realty Homes, Inc. 17-0495.00 1760 North Jog Road, Suite 120 Phoenix Realty Homes - Various Locations West Palm Beach, FL 33411 Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density .(pcf) Probe Depth (in) Percent Compaction Min/Max Comp. M Remark 30 7/16/18 P-1 N/A 11.8 102.3 9.8 105.6 12 103 98 / 105 Pass 31 7116118 P-1 N/A 11.8 102.3 9.7 105.9 12 104 98 / 105 Pass 32 7/16/18 P-1 N/A 11.8 102.3 9,6 106.0 12 104 1 98 / 105 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model I SN / Calibrated Field Technician 30 Below Slab Grade: Lot 31, NW comer of pad 0-1 Troxler 13430 / 24566 / Presson, Thomas 31 Below Slab Grade: Lot 31, SE comer of pad 0-1 Troxler / 3430 / 24566 / Presson, Thomas 32 Below Slab Grade: Lot 31, Center of pad 0-1 Troxler 13430 124566 / Presson, Thomas Remarks _ Comments ___— --- - -- — Pass: Tests results comply with specifications Tests are "Direct Transmission' (Method A) unless probe depth is noted as 'Backscatter". Gauge calibration data on rile with the testing agency. 30, 31, 32: 1-2,,2-3, 3-4 HCP=40+, > 95 % Compaction, PASS. HCP tests are em i c6lly correlated to the relative density -of the -soil. -- Tarpon Flats - Permit # 18050179 \�lttlllll/l,/' p\AN K! N& \GENSF N�63 oz So Bent, P. E STATE OF ((, PI'@��G Ionai`ggjgpgr• 18 Stal:6 Test Reports shall not be reproduced, except'in full, without the written approval of GFA International Inc. Page 1 of 1 Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Lvdia Galbraith L� From: Fran Donza <fran@phoenixcompaniesfl.com> Sent: Thursday, May 17, 2018 5:15 PM To: Lydia Galbraith Cc: Don Durante (don@stofft.com) Subject: RE: Report_FL_Review_Comments_Noncompliantjrf.pdf, 1805-0179 This is a 3 bedroom 2.5 bath the second floor shower a #4 bed room. That were I got confused it is the paper work sorry Thank you, I Fran Donza Client Services Coordinator[ Phoenix Realty Homes, Inc 1760 N. log Road I Suite 120 1 West Palm Beach, FL 33411 Phone: (561) 799-5900 ext. 105 [email: Fran@phoenixcompaniesfl.com www.phoenixcompaniesfl.com `APlease consider the environment before printing. "*PLEASE NOTE THAT OUR ADDRESS HAS CHANGED From: Lydia Galbraith <galbraithl@stlucieco.org> Sent: Thursday, May 17, 2018 4:59 PM To: Fran Donza <fran@phoenixcompaniesfl.com> Subject: Report_FL_Review_Comments_Noncompliant_jrf.pdf, 1805-0179 Fran, Attached please find the Zoning review comments and list of missing documents. I Thank you, Lydia Galbraith, Zoning Specialist Building and Code Regulation (772)462-1555 Ralbraithl@stluciecci BEST plotwork f you have any questions, please let me know. Please Note. Florida has very broad public records lam, Most within communications to or from County ofticipls regarding County business are public records available to the public and media upon request. It is the polioy of St. Lucie Camly that all County records shall be open for personal inspecfion, examination and I ar copying. Your o•mail communication, will be subject to public dirclnsure unless an exemption applies to the communication. Ifyou received this email in error, please notify the sander by reply a -mail and delete all materials tram all computers. 9