ENERGY EFFICIENCY CODE
ANNED BY FORM R405-2014 Lucia County FLORIDA ENERGY EFFICIE14CY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: AVALON_eCLASSIC_MDW 7 Builder Name: GHO Homes Street: 9619 Knollwood LN. Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: GHO Homes Jurisdiction: Design Location: FL, ST_LUCIE_CO_INTL County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Tans) 9. Wall Types (2406.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 2150.10 ft2 1.5.1 b. Frame - Steel, Adjacent R=11.0 256.67 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2520.7 sqft.) Insulation Area Is this a worst case? No a. Under Attic (Vented) R=30.0 2388.00 ft 2 6. Conditioned floor area above grade (W) 2388 b. Knee Wall (Vented) R=19.0 132.67 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(394.7 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 481.4 a. U-Factor: Dbl, U=0.62 200.00 ft2 SHGC: SHGC=0.25 b. U-Factor: Dbl, V=0.51 96.(0 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.22' a. Central Unit 60.0 SEER:16.00 c. U-Factor: Dbl, U=0.42 61.08 ft2 SHGC: SHGC=0.26 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 37. 8 ft2 a. Electric Strip Heat 60.0 COP:1.00 SHGC: other (see details) Area Weighted Average Overhang Depth: 7.0 6 ft. Area Weighted Average SHGC: 0.23> 14. Hot water systems a. Electric Cap: 50 gallonsEF: 8. Floor Types (2388.0 sqft.) Insulation Are 0.950 a. Slab -On -Grade Edge Insulation R=0.0 2388.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15: Credits Pstat Glass/Floor Area: 0.165 Total Propo ed Modified Loads: 77.81 PASS To al Baseline Loads: 78.81 I hereby certify that the plans and specifications covered by Review of the plans and O.IHE S,r this.calculation are in compliance with the Florida Enerf ly specifications covered by this Code. d calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed. DATE: % this building will be inspected for •�i �� compliance with Section 553.908 I hereby certify th is bull n , as designe , 's i o pliance Florida Statutes. ��• with the Florida r Co OWNER/AGENT: BUILDING OFFICIAL: DATE: r DATE: - Compliance requires cent! ation by the air handl I r unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in cordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 this project requires an envelope leakage test repor� with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.040 On for whole house. 9/20/2017 2:12 PM EnergyGauge®U A - v5.1 - Section R405.4.1 Compliant Software Page 1 of 5 .file Copy FORM R405-2014 PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: AVALON_eCLASSIC_MDW 7 Bedrooms: 3 User Conditioned Area: 2388 GHO Homes otal Stories: 1 1 orst Case: No GHO Homes kotate Angle: 0 Cross Ventilation: hole House Fan: Single-family New (From Plans) Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address 228 Meadowood 9619 Knollwood LN. St. Lucie Fort Pierce , FL, 34951 CLIMATE Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MU 1 2 39 90 70 75 299 58 Medium BLOCKS Number Name Area �olume 1 Block1 2388 I22288.2 SPACES Number Name Area Volur'pe Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2388 2228 .2 Yes 4 I 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 1245.68 ft 0 2388 ft2 ---- 0.8 0 0.2 ROOF V # Type Roof Gable Roof Materials (IArea Area Color Solar SA Emitt Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Flat tile/slate 2f71 ft2 0 ft2 Medium 0.75 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented I 150 2388 ft2 N N CEILING # Ceiling Type Spacel R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 19 Batt 2388 ft2 0.11 132.67 ft2 0.11 Wood Wood 9/20/2017 2:12 PM EnergyGauge® USA -jv5.1 -Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 I WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below A Ornt In Wall Type 1 S Garage Frame - Steel ain 11 22 0 9 4 205.3 ft2 0.23 0.01 0 2 E Garage Frame - Steel ain 11 1 8 9 4 15.6 ft2 0.23 0.01 0 3 W Garage Frame - Steel ain 11 3 10 9 4 35.8 ft2 0.23 0.01 0 4 S Exterior Concrete Block - Int Insul ain 4.1 11 2 11 4 126.6 ft2 0 0 0.600000 0 5 SE Exterior Concrete Block - Int Insul Main 4.1 3 0 11 4 34.0 ft2 0 0 0.600000 0 _ 6 E Exterior Concrete Block - Int Insul Main 4.1 2 11 11 4 33.1 ft2 0 0 0.600000 0 _ 7 S Exterior Concrete Block - Int Insul Main 4.1 6 6 12 4 80.2 ft2 0 0 0.600000 0 _ 8 W Exterior Concrete Block - Int Insul Wain 4.1 7 8 9 4 71.6 ft2 0 0 0.600000 0 _ 9 S Exterior Concrete Block - Int Insul Main 4.1 17 9 4 158.7 ft2 0 0 0.600000 0 10 E Exterior Concrete Block - Int Insul ain 4.1 47 4 9 4 441.8 ft2 0 0 0.600000 0 11 N Exterior Concrete Block - Int Insul ain 4.1 16 9 4 149.3 ft2 0 0 0.600000 0 12 W Exterior Concrete Block - Int Insul ain 4.1 11 6 9 4 107.3 ft2 0 0 0.600000 0 13 N Exterior Concrete Block - Int Insul ain 4.1 13 2 11 4 149.2 ft2 0 0 0.600000 0 _ 14 NE Exterior Concrete Block - Int Insul MI in 4.1 3 6 11 4 39.7 ft2 0 0 0.600000 0 _ _ 15 E Exterior Concrete Block - Int Insul in 4.1 1 5 11 4 16.1 ft2 0 0 0.600000 0 NE Exterior Concrete Block- Int Insul Mlain 4.1 5 2 11 4 58.6 ft2 0 0 0.600000 0 _16 17 N Exterior Concrete Block - Int Insul Main 4.1 6 10 11 4 77.4 ft2 0 0 0.600000 0 I 18 E Exterior Concrete Block - Int Insul M in 4.1 4 9 4 37.3 ft2 0 0 0.600000 0 19 N Exterior Concrete Block - Int Insul M:in 4.1 17 10 9 4 166.4 ft2 0 0 0.600000 0 20 W Exterior Concrete Block - Int Insul Min I 4.1 43 2 9 4 402.9 ft2 0 0 0.600000 0 DOORS # Ornt Door Type Spac i Storms U-Value Width Height Area Ft In Ft In 1 S Wood Main None .14 2 8 8 21.3 ft2 2 S Insulated Main None .14 3 8 24 ft2 3 W Insulated Main None .14 1 1.2 8 8.8 ft2 4 NE Insulated Main None .14 1 1.2 8 8.8 ft2 5 E Insulated Main None .14 1 1.2 8 8.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S 4 Metal Low-E Double Yes 0.62 0.25 30.0 ft2 1 ft 0 in 4 ft 1 in Drapes/blinds None 2 S 4 Metal Low-E Double Yes 0.42 0.26 8.0 ft2 1 ft 0 in 1 ft 11 in Drapes/blinds None 3 SE 5 Metal Low-E Double Yes 0.62 0.25 10.0 ft2 6 ft 4 in 7 ft 2 in Drapes/blinds None 4 SE 5 Metal Low-E Double Yes 0.42 0.26 3.0 ft2 6 ft 4 in 5 ft 2 in Drapes/blinds None 5 S 7 Metal Low-E Double Yes 0.42 0.26 3.3 ft2 8 ft 6 in 6 ft 0 in Drapes/blinds None 6 S 7 Metal Low-E Double Yes 0.42 0.26 6.6 ft2 8 ft 6 in 2 ft 7 in Drapes/blinds None 7 S 9 Metal Low-E Double Yes 0.62 0.25 20.0 ft2 1 ft 0 in 3 ft 8 in Drapes/blinds None 8 E 10 Metal Low-E Double Yes 0.42 0.26 11.7 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 9 E 10 Metal Low-E Double Yes 0.62 0.25 6.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 10 N 11 Metal Low-E Double Yes 0.62 0.25 40.0 ft2 1 ft 0 in 3 ft 2 in Drapes/blinds None 9/20/2017 2:12 PM EnergyGauge® USA 1 v5.1 - Section R405.4.1 Compliant Software Page 3 of 5 f FORM R405-2014 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Omt ID Frame Panes NF11C U-Factor SHGC Area Depth Separation Int Shade Screening 11 W, 12 Metal Low-E Double Y�s 0.25 0.18 12.5 ft2 26 It 2 in 3 ft 4 in Drapes/blinds None 12 N 13 Metal Low-E Double Yfs 0.51 0.22 96.0 ft2 11 ft 6 in 3 ft 1 in Drapes/blinds None 13 N 13 Metal Low-E Double Ygs 0.42 0.26 18.0 ft' 11 ft 6 in 1 It 1 in Drapes/blinds None 14 NE 14 Metal Low-E Double Yes 0.25 0.18 12.5 ft2 14 ft 2 in 3 ft 4 in Drapes/blinds None I 15 NE 16 Metal Low-E Double Y s 0.62 0.25 18.0 ft2 7 ft 9 in 3 ft 2 in Drapes/blinds None 16 NE 16 Metal Low-E Double Y:Is 0.42 0.26 4.5 ft2 7 ft 9 in 1 ft 1 in Drapes/blinds None 17 N 17 Metal Low-E Double YCIs 0.62 0.25 24.0 ft2 4 ft 0 in 3 ft 2 in Drapes/blinds None 18 N 17 Metal Low-E Double Yds 0.42 0.26 6.0 ft2 4 It 0 in 1 ft 1 in Drapes/blinds None 19 E 18 Metal Low-E Double Yls 0.25 0.18 12.5 ft2 26 ft 2 in 3 ft 4 in Drapes/blinds None 20 N 19 Metal Low-E Double Yes 0.62 0.25 6.0 ft2 1 ft 0 in 3 ft 2 in Drapes/blinds None 21 W 20 Metal Low-E Double Yes 0.62 0.25 40.0 ft2 1 ft 0 in 1 ft 1 in Drapes/blinds None 22 W 20 Metal Low-E Double Ye 0.62 0.25 6.0 ft2 1 ft 0 in 1 ft 1 in Drapes/blinds None GARAGE # Floor Area Ceiling Area I Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 580.917 ft2 685.99962666 ft2 69.83 ft 9.33 It 0 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000415 2600.3 142.75 268.47 .3113 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 60 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 60 kBtu/hr 1800 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.95 50 gal 60 gal 120 deg None SOLgR HOT WATER SYSTEM i FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 9/20/2017 2:12 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 4 of 5 FY1RM Rd0r,_9n1A DUCTS ---- Supply -- ---- F eturn ---- Air CFM 25 CFM25 HVAC # Heat Cool # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF 1 Attic 6 481.4 ft Attic I 120.35 Proposed Qn Main — cfm 95.5 cfm 0.04 0.60 1 1 TEMPERATURES Programable Thermostat: Y efling Fans: CoolingJan HeatinJan [[ ]] Feb [X] Feb Mar Mar Apr Apr f May May X Jun f Jun X Jul f JUI Aug rj Aug SeP rj Se Oct Oct Nov Nov H Dec HDec Ventin Jan [[ ]] Feb X Mar X [X] A r [Ma [ Jun [ Jul Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 9/20/2017 2:12 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PE FORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED EN RGY PERFORMANCE INDEX* = 99 The lower the Energ�Performance Index, the more efficient the home. 9619 Kngllwood LN. , Fort Pierce, FL, 34951 1. New construction or existing 2. Single family or multiple family a 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? ■ 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: Dbl, U=0.62 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.51 SHGC: SHGC=0.22 c. U-Factor: Dbl, U=0.42 SHGC: SHGC=0.26 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: New (From Plans) Single-famil 1 3 No 2388 Ar a 200 00 ft2 96.00 ft2 61.�8 ft2 37.I 8 ft2 7.026 ft. 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. N/A R= c. N/A R= ft2 ft2 ft2 9. Wall Types a. Concrete Block - Int Insul, Exterior b. Frame - Steel, Adjacent c. N/A d. N/A 10. Ceiling Types a. Under Attic (Vented) b. Knee Wall (Vented) c. N/A 11. Ducts a. Sup: Attic, Ret: Attic, AH: Main 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florid Energy Efficiency Code for Building Construction through the above energy ving feat res which will be installed (or exceeded) in this home before final inspection. Oth rwise, a n�w EPL Display Card will be completed based on installed Code compliant feat es. Builder Signature: Address of New Home: *Note: This is not a Building Energy Rating. If mortgage (EEM) incentives if you obtain a Florii 638-1492 or see the EnergyGauge web site at i information about the Florida Building Code, Er staff. Date: LA , City/FL Zip: 3y5Si ur Index is below 70, your home may qualify for energy efficient EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) ,rgygauge.com for information and a list of certified Raters. For ay Conservation, contact the Florida Building Commission's support Insulation Area R=4.1 2150.10 ft2 R=11.0 256.67 ft2 R= ft2 R= ft2 Insulation Area R=30.0 2388.00 ft2 R=19.0 132.67 ft2 R= ft2 R ft2 6 481.4 kBtu/hr Efficiency 60.0 SEER:16.00 kBtu/hr Efficiency 60.0 COP:1.00 Cap: 50 gallons EF: 0.95 Pstat **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/20/2017 2:14 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1 Building Analysis Entire House For: GHO Homes 9619 Knollwood Location: St Lucie Co Intl, FL, US Elevation: 26 ft Latitude: 280N Outdoor: Heating Dry bulb (°F) 41 Daily range � °F) - • Wet bulb (°F- Wind speed (mph) 15.0 Fort Pierce, FL 34951 Job: Avalon Lot 7 Date: 9-19-17 By: Skyetec Indoor: Heating Indoor temperature (°F) 70 Design TD (°F) Relative humidity 29 50 (%) ling Moisture difference (gr/lb) 24.4 90 Infiltration: 15 (L ) Method Simplified 77 Construction quality Average 7.5 Fireplaces 0 Component Btuh/ftz Btuh % of load Walls 4.1 7805 18.4 Glazing 15.4 5870 13.8 Doors 11.3 1463 3.4 Ceilings 0.9 2194 5.2 Floors 3.2 7460 17.5 Infiltration 1.9 4079 9.6 Ducts 10423 24.5 Piping 0 0 Humidification 0 0 Ventilation 3219 7.6 Adjustments 0 Total 42512 100.0 Component Btuh/ft2 Btuh % of load Walls 2.5 4827 15.1 Glazing 14.2 5378 16.9 Doors 11.4 1478 4.6 Ceilings 1.0 2481 7.8 Floors 0 0 0 Infiltration 0.5 1083 3.4 Ducts 9125 28.6 Ventilation 1709 5.4 Internal gains 5820 18.2 Blower 0 0 Adjustments 0 Total 31902 100.0 Latent Cooling Load = 10830 Btuh Overall U-value = 0.120 Btuh/ftZ-°F Data entries checked. -pile CO PY Cooling 75 15 50 56.9 0 �� wrightsoftm Right -Suite® Universal 2017 I7.0.04 RS000269 2017-Sep-19 11:58:05 .. Load Calculations\Skyte6Avalon Lot 7 GL S.rup Calc = < M Front Door faces: S Page 1 Component Constructions Job: Avalon Lot 7 Date: 9-19-17 Entire House By: Skyetec For: GHO Homes 9619 Knollwood Lade, Fort Pierce, FL 34951 Location: Indoor: St Lucie Co Intl, FL, US Indoor temperature (T) Elevation: 26 ft Design TD (T) Latitude: 280N Relative humidity (%) Outdoor: Heating Cooling Moisture difference (gr/lb) Dry bulb (T) 41 90 Infiltration: Daily range (T) - 15 (L ) Method Wet bulb (T) - 77 Construction quality Wind speed (mph) 15.0 7.5 Fireplaces Construction descriptions Walls 13A-4ocs: Blk wall, stucco ext, r-4 ext bd ins, 8" thk, 1/2" gy board int fnsh Heating Cooling 70 75 29 15 50 50 24.4 56.9 Simplified Average 0 Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuhlft="F W-TBluh Btuh/W Bluh Btuh/f' Btuh tsum n 352 0.143 4.0 4.15 1460 2.59 911 ne 63 0.143 4.0 4.15 261 2.59 163 e 486 . 0.143 4.0 4.15 2014 2.59 1257 se 19 0.143 4.0 4.15 78 2.59 49 s 268 0.143 4.0 4.15 1111 2.59 693 w 501 0.143 4.0 4.15 2077 2.59 1296 all 1688 0.143 4.0 4.15 7001 2.59 4369 Partitions 12B-Osm: Frm wall, stucco ext, r-11 cav ins, 1/2" gypsum board int fnsh, 2"x4" metal frm, 16" o.c. stud Windows 2 glazing, cir low-e outr, argon gas, vnl frm mat, cir innr, 1/ " gap, 1/4" n thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innll, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, mediumm 50% outdoor insect screen; 5 ft overhang (1.5 ft window ht, 1 ft slap.); 6.67 ft head ht ne all 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/ " gap, 1/4" n thk: 2 glazing, clr low-e outr, argon gas, vni frm mat, clr inn , 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, mediu ; 50% outdoor insect screen; 12 ft overhang (1.5 ft window ht, 1 it sep.); 6.67 it head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/ " gap, 1/4" n thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr inn , 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.22); 50% blinds 45°, medi m; 50% outdoor insect screen; 12 ft overhang (8 It window ht, 3 ft s p.); 6.67 ft head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" n thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innnIr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% blinds 45°, me2m; 50% outdoor insect screen; 5 ft overhang (3 ft window ht, 1 ft sep.); 6.67 ft head ht 227 0.122 11.0 6 0.420 0 4 0.420 0 10 0.420 0 18 0.420 0 96 0.510 0 6 0.620 0 3.54 804 2.01 457 12.2 73 9.55 57 12.2 52 19.5 83 12.2 125 13.7 140 12.2 218 9.55 171 14.8 1420 10.2 981 18.0 108 12.2 73 wrilghtsoft® Right -Suite® Universal 20�7 17.0.04 RS000269 2017-Sep-19 11:age 1 Page 1 ... Load Calculations\Skytec\Avalon Lot 7 GL S.rup Cale = MJ8 Front Door faces: S 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" n thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, /4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5 ft window ht, 1 ft se�.); 6.67 ft head ht w all - 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4 gap, 1/4" n thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% blinds 45°, medium 50% outdoor insect screen; 5 ft overhang (6 ft window ht, 3 ft sep.); 6.67 ft • head ht ne all 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" ne thk: 2 glazing, clr low-e outr,.argon gas, vnl frm mat, clr innr, /4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium 50% e outdoor insect screen; 3 It overhang (2 ft window ht, 3 ft sep.); 6.67 ft head ht w all 2 glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" e thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, mediu ; 50% outdoor insect screen; 1.5 ft overhang (2 ft window ht, 1 ft se .); 6.67 ft head ht 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" e thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% blinds 45°, mediu 50% outdoor insect screen; 1.5 ft overhang (3 ft window ht, 1 ft se .); 6.67 ft head ht w all 2 glazing, cir low-e outr, argon gas, vnl frm mat, cir innr, 1/4' gap, 1/4" se thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, mediu ; 50% outdoor insect screen; 5 It overhang (2 ft window ht, 1 ft sep ); 6.67 ft head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/4' gap, 1/4" se thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% blinds 45°, mediumm 50% outdoor insect screen; 5 ft overhang (5 ft window ht, 3 ft sepl); 6.67 ft head ht 2 glazing, cir low-e outr, argon gas, vnl frm mat, cir innr, 1/4I' gap, 1/4" s thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, mediu ; 50% outdoor insect screen; 9.6 ft overhang (2 ft window ht, 2 ft sep.); 6.67 ft head ht 2 glazing, cir low-e outr, argon gas, vnl frm mat, cir innr, 1/ gap, 1/4" s thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr inn , 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, mediu ; 50% outdoor insect screen; 1.5 ft overhang (3 ft window ht, 1 ft 1p.); 6.67 ft head ht 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/7 gap, 1/4" s thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, mediu 50% outdoor insect screen; 1.5 It overhang (5 ft window ht, 3 ft sep.); 6.67 ft head ht 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/ " gap, 1/4" s thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr inn , 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 9.6 ft overhang (8 ft window ht, 4 ft ep.); 6.67 ft head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/f gap, 1/4" s thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% blinds 45, me; 50% F�Sep.); outdoor insect screen; 1.5 ft overhang (4.8 ft window ht, 6.67 ft head ht 40 0.620 0 18.0 719 12.2 487 40 0.620 0 18.0 719 26.7 1068 80 0.620 0 18.0 1438 19.4 1555 24 0.620 0 18.0 432 12.2 292 17 0.620 0 18.0 306 21.7 369 41 0.620 0 18.0 737 16.1 661 2 0.420 0 12.2 22 19.5 36 2 0.420 0 12.2 20 25.4 42 2 0.420 0 12.2 22 25.4 47 5 0.420 0 12.2 65 23.4 125 12 0.420 0 12.2 146 23.5 282 6 0.620 0 18.0 108 26.2 157 9 0.620 0 18.0 162 26.2 236 15 0.620 0 18.0 270 26.2 393 4 0.420 0 12.2 47 9.55 37 10 0.620 0 18.0 172 12.2 117 8 0.420 0 I 12.2 97 9.55 76 18 0.420 0 12.2 219 9.55 172 30 0.420 0 12.2 365 9.55 286 8 0.420 0 12.2 97 9.55 76 19 0.620 0 18.0 345 12.2 234 WPI htsoft® 2017-Sep-1911:58:05 9 Right -Suite® Universal 20 7 17.0.04 RS000269 Page 2 ... Load Calculations\Skytec\Avalon Lot 7 GL S.rup Cale = MJ8 Front Door faces: S r Pro ect Summar�� Job: 9-19-1AvaloLot7 • � Date: -19-17 Entire House By: Skyetec For: GHO Homes 9619 Knollwood Lane, Fort Pierce, FL 34951 Notes: Weather:1 St Lucie Co Intl, FL, US Winter Design Conditions Outside db 41 ° Inside db 70 ° Design TD 29 ° Heating Summary Structure 32090 Ducts 10423 Central vent (0 cfm) 0 Humidification 0 Piping 0 Equipment load 42512 Infiltration Method Construction quality Fireplaces plified erage 0 ing Cooling He 2364 Area (ft2) 2364 Volume (ft3) 23997 23997 Air changes/hour 0.32 0.16 Equiv. AVF (cfm) 128 64 Heating Equipment Summa Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 57 gr/lb Sensible Cooling Equipment Load Sizing Structure 22777 Btuh Ducts 9125 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 30434 Btuh Latent Cooling Equipment Load Sizing Structure 7176 Btuh Ducts 3654 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 10830 Btuh Equipment total load 41264 Btuh Req. total capacity at 0.80 SHR 3.2 ton Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM Model Cond RA1660A AHRI ref Coil RH1T6024 AHRI ref 5437529 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 12.3 kW Sensible cooling 47200 Btuh Heating output 41975 Btuh Latent cooling 11800 Btuh Temperature rise 19 OF Total cooling 59000 Btuh Actual air flow 2000Cfm Actual air flow 2000 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.063 cfm/Btuh Static pressure 0.50 'n H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.75 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .� -- wrightsoft, 2017-Sep-1911:58:05 .mil � Right -Suite® Universal 2017 17.0.04 RSU00269 Page 1 ... Load Calculations\Skytec\Avalon Lot 7 GL S.rup Calc = MJ8 Front Door faces: S Doors 11DO: Door, wd sc type • Ceilings 16D-30td:Attic ceiling, tile, slate, concrete roof mat, r-30 ceil ins, 1/2" gypsum board int fnsh Floors 22A-cpm: Bg floor, heavy dry or light damp soil, on grade de th, carpet flr fnsh 22A-tpm: Bg floor, heavy dry or light damp soil, on grade dep h, the fir fnsh ne 19 0.390 0 e 21 0.390 0 s 24 0.390 0 w 21 0.390 0 n 45 0.390 0 all 129 0.390 0 2364 0.032 30.0 11.3 211 11.4 213 11.3 234 11.4 236 11.3 271 11.4 274 11.3 234 11.4 236 11.3 513 11.4 518 11.3 1463 11.4 1478 0.93 2194 1.05 2481 90 1.180 0 34.2 3080 0 128 1.180 0 34.2 4380 0 M c wri htsoft® 2017-Sep-1911:58:05 .C�9 Right -Suite® Universal 20 7 17.0.04 RS000269 Page 3 .. Load Calculations\Skytec\Avalon Lot 7 GL S.rup Calq = MJ8 Front Door faces: S 1 41 Schedule Exhaust Fan O Range Vent O Dryer Vent D Rheem Equipment ARI 7943714 5.0 Tan 16 SEER RH1T60 AHU 5.0 Ton 16 SEER RA1660 Cond WIC aCY 6x6 6dm 9°,4.5n 10x1QQ BR 3 '81dry IE 5°, 17.3ft 9 ", 13.6 lox 10 203 dm BR 2 a IIBath O Job #: Avalon Lot 7 Performed by Skyetec for: GHO Homes 9619 Knollwood Lane Fort Pierce, FL 34951 Garage Avalon 'lox 10 X 3.0ft 12 Nook 12 x 12 7 ", 12.4 it /168 dm Master Bedroom 4 dm 4". 4.8 ft 6x6 lox 10 / 8', 13.8 ft lox 10 130 c 154 dm F T T . 10', 12.8 It Kitchen 12 x 72 8 ", 11. t F- 239 dm 19.5 It 10x 10 154 dm 6 x 6 Great Room B °, 9.9 it His 40 dm Hers 20", 21.2ft 16',12.Oft 6", 7.8 it �30x18 4 °, 10.3 ft 27 dm .5", 5 " 7.1 ft fix6 5.1 ft 6x6 fix6 f -' O 58 dm tOx 10 SSd y WC 121 dm 8 ", 6.7 ft yer Utility 18", 17.6 it 10', 9.7 It 30x 18 12 x 12 18 ", 22.0 ft O 140 dm 20", 3.3 ft T Dining M Bath I 6 x 6 41 dm 18", 8.6 ft 4" 4.5ft Scale: 1 : 137 Page 1 Right -Suite® Universal 2017 17.0.04 RS000269 2017-Sep-1911:58:09 ...ons\Skytec\Avalon Lot 7 GL S.rup Duct System 5ummalry Job: Avalon Lot 7 Date: 9-19-17 Entire House By: Skyetec For: GHO Homes 9619 Knollwood Lane, Fort Pierce, FL 34951 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0.18 in H2O 0.32 in H2O 0.199 10.121 in H2O 0.093 in/100ft 2000 cfm Cooling 0.50 in H2O 0.18 in H2O 0.32 in H2O 0.199 10.121 in H2O 0.093 in/100ft 2000 cfm 345 ft Name Design (Btuh) Htg (cfm) (cfm) qlg Design FIR Diam (in) H x W (in) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk .-A h 904 43 41 0.190 4.0 Ox 0 VIFx 4.5 100.0 BR 2 c 3244 166 203 0.101 9.0 Ox 0 VIFx 41.7 155.0 st4 BR s C 2882 138 181 0.109 9.0 OX 0 VIFx 32.7 150.0 st4 Bath 2 C 1122 69 70 0.135 5.0 OX 0 VIFx 17.7 130.0 st2 Cabana h 2339 110 70 0.104 7.0 Ox 0 V[Fx 40.5 150.0 st4 Dining h 3707 174 121 0.115 8.0 Ox 0 V[Fx 28.0 145.0 st1 Foyer h 1479 70 55 0.115 5.0 Ox0 VIFX 28.3 145.0 st1 Great Room c 2451 107 154 0.113 8.0 Ox0 VIFx 31.2 145.0 st1 Great Room-B C 2451 107 154 0.109 8.0 Ox 0 VIFx 36.9 145.0 st1 Hers h 1671 79 40 0.097 6.0 Ox0 VIFX 41.0 165.0 st3 His c 57 2 4 0.098 4.0 Ox0 VIFx 38.0 165.0 st3 Kitchen C 3815 52 239 0.104 10.0 Ox0 VIFx 40.9 150.0 st4 M Bath h 4919 231 140 0.096 10.0 Ox 0 VIFX 43.0 165.0 st3 Master Bedroom h 3744 176 130 0.094 8.0 OX 0 VIFx 47.0 165.0 st3 Master Bedroom -A h 3744 176 130 0.093 8.0 OX 0 VIFX 44.3 170.0 st3 Nook h 4215 198 158 0.107 9.0 OX0 VIFx 35.2 150.0 st4 Utility c 932 13 58 0.138 5.0 OX0 VIFx 13.7 130.0 st2 `^/C h 624 29 27 0.095 4.0 Ox0 VIFx 43.5 165.0 st3 WIC h 1240 58 26 0.099 5.0 OX0 VIFx 45.5 155.0 st4 values have been manually overridden wri htsoft® 2017-Sep-1911:58:05 9 Right -Suite® Universal 017 17.0.04 RS000269 Page 1 ... Load Calculations\Skytec\Avalon Lot 7 GL S.rup galc = MJ8 Front Door faces: S Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR(fpm) (in) (in) Material Trunk st3 Peak AVF 694 470 0.093 497 16.0 0 x 0 VinlFlx st1 st1 Peak AVF 1153 954 0.093 528 20.0 0 x 0 VinlFlx st4 Peak AVF 723 876 0.099 496 18.0 0 x 0 VinlFlx st2 st2 Peak AVF 805 1005 0.099 569 18.0 0 x 0 VinlFlx Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rsb4 Ox0 694 470 130.3 0.093 393 1&0 Ox 0 VIFx rt1 rb1 Ox0 1306 1530 120.9 0.100 866 1&0 Ox 0 VIFx rt1 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 2000 2000 0.093 917 20.0 0 x 0 VinlFlx • Building Analysis Job: Avalon Lot 7 Date: 9-19-17 Entire House By: Skyetec Project For: GHO Homes 9619 Knollwood Lane, Fort Pierce, FL 34951 Design Conditions Location: Indoor: Heating Cooling St Lucie Co Intl, FL, US Indoor temperature (°F) 70 75 Elevation: 26 ft Design TD (°F) 29 15 Latitude: 280N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 24.4 56.9 Dry bulb (°F) 41 90 Infiltration: Daily range (°F) - 15 (L ) Method Simplified • Wet bulb (°F - 77 Construction quality Average Wind speed mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh % of load Walls 4.1 7805 18.4 Glazing 15.4 5870 13.8 Doors 11.3 1463 3.4 Ceilings 0.9 2194 5.2 Floors 3.2 7460 17.5 Infiltration 1.9 4079 9.6 Ducts 10423 24.5 Piping 0 0 Humidification 0 0 Ventilation 3219 7.6 Adjustments 0 Total 4251211 100.0 Component Btuh/ft2 Btuh % of load Walls 2.5 4827 15.1 Glazing 14.2 5378 16.9 Doors 11.4 1478 4.6 Ceilings 1.0 2481 7.8 Floors 0 0 0 Infiltration 0.5 1083 3.4 Ducts 9125 28.6 Ventilation 1709 5.4 Internal gains 5820 18.2 Blower 0 0 Adjustments 0 Total 1 1 3190211 100.0 Latent Cooling Load = 10830 Btuh Overall U-value = 0.120 Btuh/ftZ-°F Data entries checked. wrightsoft- Right -Suite® Universal 201),17 .0.04 RS000269 2017-Sep-19 11:58:05 Page 1 ... Load Calculations\Skytec\Avalon Lot 7 GL S.rup Calc = MJ8 Front Door faces: S