HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE REVISIONSCANNED
By
, - at Lucia County
Planning & Development Services Department
• Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certificatlion for Design Load Compliance
Project Name: TARPON FLATS LOT 23 - MODEL A
Project Address: 3915 Dune Side Drive Ft. Pierce, FL.
I
Permit #: Occupancy Type: R-3 Construction Type: V-B
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or m o Iti-family)
o Residential Addition
I
o Any accessory structure requiring a building permit
o Any non-residential structure!
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
i
1. DESIGN CODE: Florida Building Code Fifth Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: _I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 170 mph ASD LRFD End Zone Width: ft
5. Mean Roof Height 14.75 ft Roof Pitch: 6 :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: -44.63 Zone 2: -74.76 Zone 3: -74.76 Zone 4: -45.6 Zone 5: -57.8 Garage:
7. Design Loads: Floor: 138 PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: PSF
Dock: N/A PSF Deck: N/A PSF iStairs: N/A PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? x Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided?. X li Yes Not Applicable Explain Why Not:
i
10. Design Soil Bearing Pressure: 2+500 PSF Soil Test Reports Submitted? X Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plan vi - quate re ' tan ce t the design
forces specified:
Signature, Date, and Seal
Revised 07/25/2014
Print Name
Project Classic LLC
4
1f
Company Name & Address
1 1 0: •