HomeMy WebLinkAboutREVISION 4-16-15MIAM
Now, I.
SCANNEF3
BY
St Lucia Countv
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION I
NOTICE OF ACCEPTANCE (NOA)
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T(786)315-2590 F(786)315-2599
www.mismidtidt.gov/economy
DAB Door Company, Inc.
12195 NW 9811 Avenue,
Hialeah Gardens, FL 33018
SCOPE: This NOA is being issued under the applicable rules and regulations koverning the use of construction
materials. The documentation submitted has been r6lewed and accepted by Miami -Dade County RER-Product Contro I
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In
-Miami Dade County) and/or the AHJ (in areas other than Miami Dade County),reserve the right to have this product or
material tested for quality assurance purposes. If tl�is product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testingand the AHJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoki this acceptance, if it is d ' etermined
by Miami -Dade County Product Control Section.ithat this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein, anid has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone. i
DESCRIPTION: Hurricane Mater Model 824/811 Steel Sectional Garage Door up to 16,-21, W/
Window Lite Option (DP +48.0, -52.0 PSF)1
APPROVAL DOCUMENT. Drawing No. 98-05, titled "24 GA. Roll Formed Steel Sectional Garage
Dooe', dated 02/23/1998, with last revision L I i dated 03/05/2015, sheets I through 6 of 6, prepared by At-
Farooq Corporation, signed and scaled by Javad Ahmad, P.E., bearing the Miami -Dade County Product
Control renewal stamp with the Notice of Ac I ceptance number and expiration date by the Miami -Dade County
Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: A permanent label with the m I anufacturer's name or logo, manufacturing address, model/serie's
number, the positive and negative design pr6ssure rating, indicate impact rated if applicable, installation
instruction drawing reference number, approval number (NOA), the applicable test standards, and the
statement reading 'Miami -Dade County Pro0uct Control Approved' is to be located on the door's side track,
bottom angle, or inner surface of a panel.
RENEWAL of this NOA shall be considered'after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product. -
TERMINATION of this NOA will occur aft I er the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
I
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job siteat the request of the Building Official.
This NOA renews NOA # 14-0814.08 and consists of this page I and evidence pages E- 1 and E-2, as well as
approval document mentioned above.
The submitted documentation was reviewed by Carlos M. Utrera, P.E.
NOA No. 15-0302.01
MIAMI-DADECO Expiration Date: July 21,2020
Approval Date: April 23, 2015
Page 1
ROMBALL E. STOFFT AR, ci-IqTp
AM03379 �ICT% pA
A1103 I 1105
E�APPROVED 0 REVISE & RESUBNUT
0 APPROVED A20ORRECTED 0 PEJECTED
lew
This reI4 is On' forger. ; eral conformance vvith the daslign concept of the
I
Project and goneral corrpi once vjith the infom 8,
1 1101 giv-611 in the contract
d- , 'cuments. Corrections Or comments mads on the shop dravvirigs; during
th! I&JIOW �i
:3 do not refluve Me contrac lor Torp wore.pil -r,.Ca With the requ!re-
Of the plans and specifications. Approval of a sPecN-Ic ilem shall not
i;"`!,&aPPrGY2`Ofaf.I assembly of which &,,e ii
'em Is 8 CoTnPonsi Lt. Con-
recponaible for: Dim.ansions; to ba corift, mad and con-e!atad at tlie
'G,n
t�,at Dert ; s so!ely to the fabrication procossas or to
rn%�ods, techniques, sequences and procedure-s of construc-
Uon: coordinaftun of the wor? of all other trades: and for performing all work
in a safe and s2tisfactory-manner.
DATE: — I BY: �w
MIAM
Nor, - - I
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miam!dAdt.gov/�conoml
DAB Door Company, Inc.
12195 NW 981" Avenue
Hialeah Gardens, FL 33018
SCOPE: This NOA is being issued under the applicable rules and regulations �overning the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date �stated below. The Miami -Dade County Product Control Section (In
-Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) ireserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AFIJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined
by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the
applicable building code.,
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: Hurricane Mater Model 824/811 Steel Sectional Garage Door up to 16'-2" wl
Window Lite Option (DP +48.0,-52.0 PSF)
APPROVAL DOCUMENT: Drawing No. 98-05, titled "24 GA. Roll Formed Steel Sectional Garage
Dooe', dated 02/23/1998, with last revision L dated 03/05/2015, sheets 1 through 6 of 6, prepared by Al-
Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product
Control renewal stamp with the Notice of Acce�tance number and expiration date by the Miami -Dade County
Product Control Section.
MISSILE IMPACT RATING: Large and 9mall Missile Impact Resistant
LABELING: A permanent label with the man : ufacturer'snarne or logo, manufacturing address, model/series
number, the positive and negative design pressure rating, indicate impact rated if applicable, installation
instruction drawing reference number, approval number (NOA), the applicable test standards, and the
statement reading 'Miami -Dade County Product Control Approved' is to be located on the door's side. track,
bottom angle, or inner surface of a panel.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product: -
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety. A
INSPECTION: A copy of this entire NOA shall be provided to the u u 4, t i t
shall be available for inspection at the job site at the request of the Buil
This NOA renews NOA # 14-0814.08 and consists of this page a as
approval document mentioned above.
The submitted documentation was reviewed by Carlos M. Utrer
MLAMI-DADE COUNTY
wom"M 15
Approval Date: April 23, 2015
File COPY Page 1
NOTICE, OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. 98-05, titled "24 GA. Roll Formed Steel Sectional Garage Door", dated
02/23/1998, with last revision L dated 03/05/2015, sheets I through 6 of 6, prepared by At-
Farooq Corporation, signed and s6aled by Javad Ahmad, P.E.
B. TESTS "Submitted tinder NOA # 11-04!14..Z3
1. Test Report on Uniform Static Ai I r Pressure Test, Loading and Forced Entry Test per FBC,
TAS 202-94, of "DAB 824 Sectional Residential Garage Dooe' prepared by Hurricane
Engineering & Testing Inc., Report No. HETI-07-4267, dated 06/2912007, signed and sealed
by Candido F. Font, P.E.
2. Test Report on Large Missile Impact Test per FBC, TAS 201-94 and Cyclic Wind Pressure
Test per FBC, TAS 203-94, of "DAB 824 Sectional Residential Garage Door", prepared by
Hurricane Engineering & Testin : Inc., Report No. RETI-11-3206, dated 02/10/2011, signed
9
and sealed by Candido F. Font, P'.E.
3. Test Report on Tensile Test per ASTM E8-08 of "Sectional Residential Door (skin)",
prepared by Hurricane Engineeriftg & Testing Inc, Report No. HETI-11-T101, dated
I
0 1/29/2011, signed and sealed by. Candido F. Font, P.E.
"Saimitted undertvuA v 05-021 Z 02"
4. Test Report on Large Missile Impact Test and Cyclic Wind Pressure Test, of "Sectional
Residential Door with Windows'l' prepared by Hurricane Engineering!& Testing Inc., Test
Report No. HETI- 03-1328, dated 07/15/2003, signed and sealed by Rafael E. Droz-Seda, PE.
5. Test Report on Uniform Static A 1 6 Pressure Test, of "Sectional Residential Dooe, p repated by
Hurricane Engineering & Testing Inc., Test Report No. HETI 03-1329, dated 07/15/2003
signed and sealed by Rafael E. Droz-Seda, P.E.
6. Test Report on Tensile Test per'ASTM E-8 of "Sectional Residential Door (skin)" prepared
by Hurricane Engineering & Tes I ting-Inc, Test Report No. HETI 03-T078, dated 10/31/2003,
signed and sealed by Rafael E. 13roi-Seda, P.E.
"Submitted under NOA # 03-02 10.04"
7. Test report on Salt Spray (Corro I sion) Test per ASTM B 117 of a painted G-40 steel panels,
prepared by Celotex Corporation, Test Report No. 258592, dated 08/17/1998, signed by W. A.
Jackson, P.E.
C. CALCULATIONS "Submitted under NOA # 14-0814.08"
1. Anchor verification calculations prepared by Al-Farooq Corporation, dated
09/22/2014 and 07/24/2014, signed and sealed by Javad Ahmad, P.E.
Carlos M. Utrera, P.E.
Product Control Examiner
NOA.,No. 15-0302.01
Expiration Date: July 21, 2020
Approval Date; April 23,2015
E-1
DAD Door Company, Inc.
NOTICE OF ACCEPTANCE:, EVIDENCE SUBMITTED
C. -CALCULATIONS (Cont.) "Submitted under NOA # 09-0128.0111
1. Anchor verification calculations prepared by A]-Farooq Corporation, complying with F.B.0
2007, dated 0410512011, signed and scaled by Javad Ahmad, F.E.
"Submitted under NOA # 09- 0128. 01 "
2. Anchor verification calculations prepared by Al-Farooq Corporation, complying with F.B.0
2007, dated l2h8/2008, signed and sealed by Humayoun. Farooq, P.E.
D. QUALITY ASSURANCE I
1. Miami -Dade Department of Regu latory and Economic Resources (RER)
I,. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 13-0717.01, issued to SABIC Innovative Plastics, for their
Lexan Sheet Products,'approved on 11/2 8/2013 and expiring on 07/17/2018.
2. Notice of Acceptance No. 14-03k.08, issued to Insulfbam, LLC, for their
Insulfbain Expanded Polystyrene Insulation, approved on 08/14/2014 and expiring on
11/29/2017. 1
3. Notice of Acceptance No. 11-092�.07, issued to Dyplast Products, LLC, for their Expanded
Polystyrene Block Type Insulation, approved on 11/10/2011 and expiring on 0 1/1112017.
4. Notice of Acceptance No. 11-092 1 �.06, issued to Dyplast Products, LLC, for their
Dyplast ISO-C 1 Polyisocyanurate Insulation, approved on 11/10/2011 and expiring on
01/11/2017.
5. Notice of Acceptance No. 10-112 1 9.04, issued to Cellofoam North America Inc, for
their Expanded Polystyrene Block Insulation, approved on 02/24/2011 and
expiring on 02/24/2016.
"Submitted under NOA # 05-0228.02
6. Test Report on Accelerated Weathering Using Xenon Are Light Apparatus Test per
ASTM GI 5 5 of "PVC, Extrusion Material", prepared by Hurricane Engineering &
Testing, Inc., Report No. IIkT1 04-AO02, dated 09/27/2004, signed and sealed by Rafael E.
Droz-Seda, P.E.
7. Test Reports on Tensile Test per ASTM D63 8 of "PVC Extrusion Material", prepared by
Hurricane Engineering & Testing, Inc., Report No. HETI 04-T251, dated 11 /29/2004 signed
and sealed by I. Ghia, P.E.
8. Test Report on Self -Ignition Temperature Test, Rate of Burn Test and Smoke Density Test
of "REHAU non -foam PVC extrusion material", prepared by ETC Laboratories, Report No.
04-761-15019.0, dated 05/06/2004, signed and sealed by J. L. Doldan, P.E.
F. STATEMENTS "Submitted underNOA # 14-0814.08"
1. Statement letter of code conformance to the 51 edition (2014) FBC and no financial interest
issued by Al-Farooq Corporation, dated 05/13/2014, signed and sealed by Javad Ahmad, P.E.
Carlos M. Utrers, P.E.
Product Control Examiner
NOA No, 15-0302.01
Expiration Date: 'July 21,2020
Approval Date: April 23,2015
E -2
�GALV, STEEL CENTER 111G ------ �,PUSH ALI
W/ (4) 014 X 5/8- SUS
WIMOUr DELRON SLEEVE (STO')
7-1/2' X 3* X .07,"
on R. I
W/ (6) 11 1
. nv/--.-S-,� 4
WITHOUT 11UIO" SLEEVE (STEL,
WITH 'ELRON SLEEVE (OPTOIAL 11"
UV�2- X 2- 071, 11
STEEL C=X 91RGE
W/ (4) 014 X 5/8- SMS LOOK
WIN DELRON SLEEVE (OPRO)MIL) 2/ DOOR
I' W X .15 THIK LATCHL,
IR HING STAN ON
VAN. —ED SUDE BULL (EXITH S*�
, Z?TPE W/ (4) 014 X 1/2 ' SM.!L a
D
5/8 WIN. LOCK ENGAGEMENT
CONFORUS TO, SECTION 1008 REGARDING
GARAGE DOORS
.15,, DIA. GALV. AIRCRAFT TYPE
W/F. & NICO-PRESS SLEEVE
LIA. 5 To I SAFETY FACTOR
7' X 3' X 0.1"
WON C,
") 4 X 3/4'
SELF D.LLfNG SCREWS
BRACK BRACKET
SEE . LIFT DOOR LOW HEADR M
Dan
OF
M. I OF
v AT
W-8,
2 SECTONS 16'
2 SCOTONS 21'
r
SECTORS 21'
n— IV
S— I..
E—S le-
I so—
2--2V
-1'
2 SLCTIONS IlY
iff
21-
W=ONS 21'
4
,w
w.,-
I SOCTOI13 10-
2 —S Ir
1
3 SECTKNS 21;
, sECTINS 2r
5 5-5 21-
jo-w
a
G —NE Ir
I SECTON 21-
5
ll�r
S S— 1.-
4 S.— le-
2 S— 91;
EECTXNS 21-
ll�w
3s—NS 1.
E—S W
S—S 2
SECIXNS 21-
IX-1
I —NS 11-
SEC—S 21-
-
12'-W
W-W
e -- 'a'
, sucTows IF
� — 21
3 SIXTONS 2iw
W
ls�_r
4 —NS W
3 =00S Ir
4 — 21-
5 30MIONS 2V
2 SECIONS Mu
6 SEGIVINS 21ffi
--a
5 SECTIONS I.*
TSErms 2"
I E— 21-
15--3'
2 —DRS la-
r-- 2i;
7 — 21-
I S— W
1 2.-
SECDONS 21'
Top FIXTURE 5-1/2* X 2-3�41- X 0.1-
STEEL PLATE WIN ONE ZQG-18 US W/ WIT
/FASTENED 10 Ell SMILE
(6)
SE&HEST "e SILIF DRILLING SCREWS
. 4 FOR TOP BRACKET OPTIONS
CENTER STILES I
SEE SC4. 'A-F-,-._�
OPTIO DOOR VIEWER
TO BE INSTALLED AT
ANY CENTER 7
R 0
7 �2nL
1w; X 3-1/8, X CIO' CRIONA]. VENTS 0
U.— PLUS. L—A 0
(3dmw WOE AT 7 C. I%X. FLUSH FACE
LATE C AN " 0 WOOD GRAIN DESIFGANCE
WITH (4) jt4 X 3/4 SOS L EA NOT To EXCEED 1201 SO.
C04TER snLE DAB DOORS INC.
INSIDE ELEVATIO H rricane Mostere Model 824/811
OUTSIDE �11�" EN1 SILE RAISED PANEL EMBOSSED DOOR
HANDLE M— Sim 16'-2' X IS--O- ffgh
F1 I �./,4',% Wilth WiNl.. I.R. Opli..
L . BAN GUIDES IN SALS DESIGN PRESSURE RATING = + 48.0 PSF
ON 52.0 PSF
END SITE FiWIS PRODUCT Ii RATE� FOR LARGE MISSILE IMPACT
WITH (4) 114 X 5/8. Gus
AST X SW LOOK RAL, 1. TINS PRODUCT HAS BUN DMGNEO AND TESTED TO COMPLY WITH THE R
ENGAGES IN TRACK REQUIRCLIEWS OF THE FLOXIM DMIN ) WIN WITION (2014) .8 31 1
RIG Zg�=
oMrON EACH SIDE OF DOOR CENTER SIRES -A! INCLUDING " VELOCITY ""C'"
CONTI, MIES CONFCOMNON 2. ANCHORS SHALL BE AS LISTED SPACED AS SHOWN ON DETAILS. 2 2 a
-----T ANCHOR EMB MEW TO BASE MATERIAL SHALL BE BEYOND WALL
OPTIO EXXA mm ""S DRE [NO OR STUCW.
70 91-10* OF C22M
ALL BOLTS. NUTS AND WASHERS SHALL BE ZINC PLATED CARBON STEEL.
LOCK BAR LOCIONG :! K 7-7�
4. ANCHORING OR LOADING CONDITIONS OTHER THAN NOSE SHOWN IN A
ALTERNATE TO .1�il�WM
En: 111 ME
I m
I m
I m
i
i. I:
SON],
I
=1
in
licnijilmilml
-m
101111
710-11
111IM711
1 Wil
Fm-1
r1m:7111
1
71mil
WIN
71=
111
ME,
I
M
Im—
Ems
1
SPRING LIMBED SLIDE BOLT W-,�
LOCKS SHOWN
12 To
-0, TO
4
THESE DETAILS ARE NO
,�OTO
ALCOVE N Wa�
INS
TO LET— 1
5 A LOAD OMEN ME
m
GCK)R mu"S
WIDTHS
lum To SH 2
rN U-W P
.2
8_0
MEMO
UNKSM
iulo.-:
1 nal,
1 0
MIN
min i. I
2A
'Fr
1! 1.2 Hil! I H 91 !1
4 GOL ROLL FORMED SM MORAL CAME D ALFAROOQ CORPORATION I a
DAB DOORS INC. malm�&—oouuomwm�
�&W- AW
12195 NX 98 TH. AVE. M�4 RDAW174
HIALEAH GARDENS, FL. 33018 1 � (M—) 2
� (�) SSS - M2. _ _ j! I GARAGE\9E-05DAB
Gloz 0 S
9--u-Ru=
�0� mmou NuuN M' x �a SCZ
-(BMM
tlL9d
A
"vN, uno,
E"'. lo
30NIH mou Ga
30WH MIN"
= WIM
WN
1108 SS dz-#71,
" x ZII-L 3ais Nowum
F
_0901 x oll-L
ofrows i3lom Hoj c � N'
DXM9 Wd 'o
'IWI 3003 ' M.Z
'*NO3 01M =,a 'NWI
M JIM-S3MOd .9/
TIAM 3A3 B a3NOWSOd
I 31US MN33 NJ S310H va gt/u Ni 03T[ViSNI
30a3
.3HvmawH Au?jn33S 30YIHOS. AS
SLUH mm -I/C
RM STMd ".'.-:(R E
M3LS GM' X .9/t-g X Z K
F: 0
0 p Im 30
U) MNVd -US *W
.�z 11- 1113
0 �ILS
.91
lz moi
d.d 11/1
.0
0
W.
S3109
\--13WJ HMO Me SdfU
61F
V. SL�d .91A W A 13Wd 01
C313NU OW Q3M9 t� 8
z x .9 L-I
aw x ./S ��1433
�U 40d .91A W
M Mn33S w "3Wd M MIno
onsw GGW x */c- I x o/1
XMI9
UMVISM NO
Om,=M dOIS 'M
ONIONDIN138
I
Ems
I ws ommua sm .#/c x vt I unw /a
CN3 M M *S'lTS .9/9 X tl I OMI IM
UMM— � M �l MlW
ssna o o�
NMN.t/c xTA � w�
a x E x w 91
L FRI -
q
/M
MWYdS Voi C 12� MIS
S13X.WS NO= I—
.06V x rc x aL.z x wl
S , .
3�"
/1 3— -. --
(03GY38HI ).TtfU)
M3M MI .9/9-1 X .91/S
HLEM eW GODM 01
U]I�J 13X3VHa NMI 133LS
DN1090JN138
= a
,/C-t X.r/l
Swum ,35 .,/c x
31US GN3 01 aw *S�
A NJUS mm
, WU MWd
"'M 5/16' X I
2-3/4- X S-1/Z' X - X .104-
-5/q" LAG SCREWS INTO WOOD OR
/- GAVY' STEEL. WITH 1-1 5/16- SLEEVE ANCHORS
zoT ROLLER smooKEr ON EACH SIDE
ENED W/ (6) 1 14 X 5/8- S.M.S.
.OSO THIC GAVI. STEEL. ADJUSTABLE 2-1/2- X 4-1/4- X I
WELDED TO 1-1/2' � 1-1. X
Z'w'/'5/'is-ia x.3t�'=EHEAD H. TO -E
M. SCREWS - _"K
-\ WITH (4) 1/41-20—�. BOLT & Nun
A- f \HORIZONTAL RE IH:R =---- DOOR
I
,%X I- * X .055" FORAZO STEEL
TO FANEJ. AND FASTENED TO
2' X 5-1 2
(2) 3116- MP RwErS V!
E;
FASTENED W/W)R g UL4 XjaX*Ui.M.S.
MR
LOW HEADROOM DOOR OPTION
HDRIZON� RENFORCEMENT
ILQ701-3/4' X G58' PERMM STE
VMEL AND FAST114ED TO
VERnn STRUES WON
(2) 3/16- POP METS
5/16- MEETING RIB
M X .5 STEEL ROU-ERS
W1 .44 DLIL X 5- STEM
OmNA-
EN 'O-AST PRCE= LLC'
EPS-WAN ED PGLnWRENE
oGHSGy . jGs mr
NOA III-0926-OT
OR
ISO-25 PMY-WaANURATE
SITY - 2.0 PCF
H.O.A. J11-0926.06
. ....... OR
..........
DENSTY - 1.0 PCIF
..........
N.OA JIG-1129.04
BY-.."
bit N.DA 114-031i.oa
14 GA. MY. STEEL
ROL
GHLER K GIES FASTEHED
W/ (6) 1 14 X 5/8' SMS
WN. .02 ' ROLL FORMED STEEL PARM
DRAW= 0 0-40
.H, -LID STRm - 39 Ksl
WITH PRIM AND —EG-EN
PILYSIER PAINTED TOP IlAl
APPLIED TO BOTH SIDES Ol' STEM
12 CA. CAM STEEL
YBOTTOM � FASTENED
W/ (4) J 14 X 51a- SMS
SEE SHEET 3
M S- BIT—
SEQMON A,
SEE SHEET 2 FOR LO0TION
OF REINFORCING TRUSSES
HOBO. TRACK SUPPOKr.
FOR MR 400� U ' 7 Fr.
CENTER SUPPORT FEN. ON 000
EXREETING a Fr. N HOG
IN OR, �.
:r X V X 1/8' HORIZ. ANCLE
11
FOR DOOR HEIGHTS ABOVE 7 FT. OR
DDORS WITH INSUI.ATION OR WINDOWS
.1
z
SPOT WELDED TO HDRIZ. TRACK
/2- APART
nw AT a�o c. REST AT 9' D.C.
0
I
A—i
CONNOCHED TO FIL,G BRACKET ANGLE
RIZ. TRACK LENGTH OPENING HEtCHT PLUS 12"
-" "' GO T
W/ 3/8 RH'G './ NIE M
AND TO SP
(2) 1/4-20 X 5/8- BOLT 4 HUT
il
,rl4 GA, MV. STEEL TRACK
cy
VERTCAL TRACK
0
2-1/9* X I" X OW
SECTRON A -A
oe�u
X I
OR * ECTION M BRACKET PLACEMENTS
HEIGHT I ST12RD13RD14TH15THI Bi 62 1 83 1 B4 I BS 1 95 1 137 1 88 1
-0 1 :, la, is" N 1" 7 2' - 4 2 34� 56 -
6'-6" 21' "118 121' NIA I" TO 2' 2r
7'-.' Z1-121'121"121'IN/All' TO 2' 2 D.:�L4 E:H!.jf
T r G7'
I - IS. I - .11-70 2- 34' 1 45' 1 56' 111 _" 78-1
B'-D' IS 1�
7%18�188-118 li-314-1 23, 3
-::�S ARE NUMBERED STARTING AT THE BOTTOM
FOR DOORS MORE THAN 8 Fr. HIGH. USE ADDITIONAL TRACK EINACKETS AT 10- O.C.
I.S" X 2.19" X 325' X .090*
STEEL TRACK ETS
2-3/1 S' H GH
CONNE001) TO TRACK WITH
1/4- BOL" & HUM
E
0 Eig
12
g
0.,
w
"i
BE
VrRllCAL Ll HIGH LIFT STANDARD Ll LOW HFMRQ0
DOUBLE TRACK
AVALARLE.TRACK OPTIONS
g. AIM m MODUCTREINMED
L
F.A. PE jM12 "—pta�nd.Fbomrkk
LgS-0�5
3 4'
W. 1/2' X "C x .08,
18 x I- FORMED STE
>F- Z-112-
aSE
ST. ELF DRILUNG SCREWS is x I-
kfi�
1-1/2" MIN. OR SELF CRLMIG SCREWS
I 3/16"RNIEWSTM. RhYTS-\
UULTIGRIP W/ DO HEAD '07". --w STEEL RliETS
z
0
AT 48' O.C. UMP P W
I Lfa�
AT 48�Mo ! DOME HEAD
C
kt
---EMT
1/2' X 1-3/4' X
FORUM (D (D
CIA. LAG SCREWS I/ ammscREwS,
2BY 2"
;A
WOOD Ex, WOO BU AT MOM ENDS
1�1/4-
"L -a A ENGS
AND 11, D.C. MAIL AND a-
ADAPTER
9M
STEM
0
RUBBER WSTRIP"ING-1 RUBBER W`STRJ`PING
I
M4
"'
- I F; -
i
,
1750---
u
RMOM SEAL ORnONS
OPTION
WOOD ELICK CONNEqION TO WOOD SUBSTRATE (WC0D SPECM0 0R0&ffY SG-0.55 LON.)
!2
IN INSTALLATION METHODS SHOWN ABOVE SHOWS 2X6 SYP WOOD RUCK ATTACHMENT
To woo mucTuRcs. IF TNEsE METHODS � FOLLOWED NO ADCRIONAl. ChCULATIGAIS/OESIGN
WILL BE REQUIRED FOR DESIGN or GAME DOOR ANOOFMC
FOR DOOR R�EMENI APPLICATIONS W114 NO EN NEER OF REVORD. INSIALLATRON MAY BE SPAGBIG
VERnM AND APPROMM W THE BUM.OUNG OFFICIAL UPON INSPECTION. —
J
Z M;
ROM
Rz- PVA
1/1 11 ��M:;J]i%KMKPIR;4Z 8�114
5/16" X 1-51W 3/8
3/8
L40 SCREWS. .1— UCTURE BY ORNMRS POVER-.— co— 1 2- 1 s-
MUST SUPPDRF FILE LOADS w,0sE,D
BY ... Ri sysTru WK. I —/�- I a I -
CONCRETE r. 3000 PSI MIN.
5/1V DIA. BOLTS C, GROUT FUJIM MOCH 2000 PSI MIN,
WASUOR � RIFT
p-n
AT 12" O.C. MA)f. EDGE OiST.
��ee�T1511N TO hMON
WOOD �JAMRS WHICH SKML BE ANCHORED TO
OR REINTIORCED MASONRY MOM MOM. OR CCNC. COLUMN WON F
I/ ' ULTRACON! BIT 'EUrO' WITH SPACING or
*RH
I ?- D.C. INTO GRcuT nUJE0 SMCI( WALL. �4�M. EMBED 1 2 -,yGfi X 14 CA
9 D.0 INTO 3000 PSI CONCRETE. VWM I -3/4-WI am 1-1/e C�$.l FEEL I - "I/-
2-1/2- MIN. EDGE DISTANCE
1/4�' TAPPER WITH SPACING OF 12 GA. GAM STEEL
MIN. EUBED IV x 2
rqOUT FILLED BLOCK WALL WITH I 1 11 rA
FLAT 8RAcxErs *3' LONG 2-10�X
B. 0 -1/2n
�C. MIND AT ;82: OC. IN DOOR OPNO. CAL EE
S
.G. INTO 3000 PSI CONCRETL Wall 1-3/4' MR. EMBED L
H
3. M Q. D.0 AT O:C. All� DOOR OPNO. FA
IT C
RL EDGE STANCE CONNOCTIM TO CONT. F/SrM TO TRACK PLATES
M 21 2DICS
=2 1/4- TRUSS No.
W1 (3) SPOT WELDS AT EACH
3/8' C "E". U' 'E"'D SIDE M.S LZ NUT
2 1 rOTTIM-D ffw %TFN S'AIRRO or R'EVER!SE
WOO PSI CONCIRETE, WITH 2-1/2" MIN. EMBED
r MIN. WCE DISTANCE
318. HUG SLEEVE BY MIT Wful VACING OF
a. 0. C. INTO MOLT FILLED Guam WALL, wnR 1-1/4- MIN. EMBED 4- MIN. EDGE DIST. ALTERNgE TRACK INSIALLATIO
11. M =0 P9 COWGRET" W'" 1-1/4- MIN. EMBED AND
/02-C.
2-1 - MIN. EDGE DISTANCE
BY OTHER GNX PRUIBLICIINUMINED
FOR NEW CON UCITON ENGUIEER OF RECORD OR ARCHITECT TO MEBFY
ADEQUAC, OF SUPPORIONG STRUCTURE TO, SUPPORT LOADS IMPOSED
BY DOOR SYSTEW.
FO DOOR REPLACEMENT IN RETROM HIALCINGS WITH NO ENGINEER OF
RE . DOOR INSIALLAROM MY BE RINTENED AND APPRMD BY
BUILDING OFFICIAL UPON INSPECTION.
D
uA,aUuu —(+) MIAB, PER AMB (16. 17- X 48 PSF)/2 � 358 0, p, R.
:
MA)UNUU! INTERIOR(-) LOAD PER MJUB (16.17- X 70 PSF)/2 - 420.4 � p� Ft.
.J.
We
IR PANEL
M (.024) STEM
(10' DIA. WASHER
-,_18 X 3/4- SMS
a i M ENDS
AND'� D.C. LUOL
(4) ja X J/4-
- i 3/a- m. mas
ARID 6-1/2- D.C. W.
.175 X OU DEEP
GROOVE
1/4 POLYCARBORATE LOM
GY C MMA� PLASM'
INGA 913-0717.01
I x
OVE
(4)118 X Z wS
a �/VF M ENDS
AND �1/2' D.C.
18
DL, WASHER
DOOR
�4 - (..,) —
I
N 1001.
RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS
#a X 3/4' WINDOW LITES CAN BE IN ANY LOCATION IN DOOR SECTION
0 3/6* — ENOSi /_.175 X .082 DEEP
AM �1/2* ac. GROOVE I