Loading...
HomeMy WebLinkAboutTRUSS PLACEMENT PLANWARNING -THIS IS A PLACEMENT PLAN FOR ENGINEERED -BRACING: -SEE FINAL ENGINEERING SHEETS FOR THE -BACK CHARGES WILL NOT BE ACCEPTED UNLESS OUR LL BEARING POINTS MUST BE COMPONENTS AS DEFINED BY WTCA 1 - 1995. 1) FOR THE ERECTION BRACING FOLLOW STRUCTURAL DATA, NUMBER OF GIRDER AND TRUSS DESIGN DEPARTMENT APPROVES THEM IN ADVANCE DIAPHRAMS HAVE NOT BEEN ANALYZED BY NSTRUCTIONS ON THP- BCSI-131 SUMMARY SHEETS PLIES AND THE CONNECTION INFORMATION. -ALL HANGERS ARE SIMPSON STRONG -TIE UNLESS NSTALLED PRIOR TO INSTALLING IN EAST CAOST TRUSS. 2) PERMANENT BRACING FOR THE STRUCTURE IS HE -OUR DESIGN DEPARTMENT MUST APPROVE OTHERWISE NOTED. INSTALL HANGERS ACCORDING NY TRUSSES! 'FOR ERECTION AND INSTALLATION OF TRUSSES RESPONSIBILITY OF OTHERS. ALTERATIONS AND/OR REPAIRS TO TRUSSES IN TO THE CURRENT SIMPSON STRONG -TIE CATALOG FAILURE TO DO SO MAY RESULT FOLLOW INSTRUCTIONS ON THE BCSI-B1 SUMMARY 3) INSTALL WEB BRACING AS STATED ON SEALED ADVANCE. DAMAGED TRUSSES AND WILL VOID ALL WARANTIES. I SHEETS AND SEALED ENGINEERED TRUSS DRAWINGS JENGINEERING TRUSS [DRAWINGS. I I I 9'-4" PLATE HT. 10'-8" PLATE HT. 0 A HAW)WARE: =HUS26 HANGERS (QTY. 15) =HTU210 HANGER5 (QTY. 1) Indicates Left End Of Truss TRUSS PLACEMENT PLAN L%131NEFR__rJ , ;? 0 YS SY S I f, *V S EAST COAST TRUSS 5285 ST. LUCIE BL)v'D. FT, PIERCE FL. 31046 OFFICE: (r$2)466-2480 FA1 (772)46fl-5336 STOMER:GHO Homes B NAME: Spec.Residence DRESS:Lot 7 Meadow Wood Y/COUNTY:Ft. Pierce/St. Lucie OB # J34562 OB # DEL:Avalon Classic SQ FT 3286 DATE 09/21/17 ILA I EbT=/ I) 61G15S-31.003 (3) (C), EAST COAST TRUSS is the T .... De,i,. E,irtee," Tits,. .,e desi,ed in .,.rdiste� v,ith the Fl.rid. R.0dim, Cede By approving this placement plan(s), gnatured anywhere on this sheet, the customer r his representitive acknowledges that this lacement plan complies with the structural intent f the project. The customer also acknowledges that this pproval authorizes EAST COAST TRUSS to ianufacture these trusses and deliver them to ie project indicated on this drawing. The customer also acknowledges that he/she ocepts financial responsibility for any repair, ngineering, and labor required due to errors ther than those of EAST COAST TRUSS. ODE = FBC 2014/TP12007 ASCE 7-10 ESIGN CRITERIA =MWFRS CCUPANCY CATEGORY= 11 KPOSURE = C WF SPEED = 160 JILDING TYPE =ENCLOSED EAN HEIGHT: 16.00 FLOOR: DUR FACTOR= 1.0 PSF=TCLL-TCDL-BCLL-BCDL 40.0,20.0,0.0,5.0 ROOF: DUR FACTOR= 1.25 :ISF=TCLL-TCDL-BCLL-BCDL 20.0115.0,10.0*,10.0 "NON -CONCURRENT BC LL 10psf CONCURRENT BC STORAGE LL 20 psf MWF MAIN WIND FORCE C&C COMPONENTS AND CLADDING TOB TOP OF BEARING TC = TOP CHORD BC = BOTTOM CHORD LL = LIVE LOAD DL = DEAD LOAD psf = POUNDS PER SQUARE FOOT # =POUNDS UNLESS SHOWN ON ENGINEERED TRUSS DRAWING. ALL GIRDER/COLUMN LOADS MUST BY-PASS FLOOR TRUSS UNLESS SHOWN ON ENGINEERED TRUSS DRAWING. ---- ------ -- . . . .. . - , . - - - - - -I RECOMMENDED ON FLOOR TRUSSES SPANNING 20i-0" OR MORE LIST BE SET WITH A SPREADER BAR. THE :'READER BAR SHOULD BE AT LEAST 1/2 IN LENGTH AS THE SPAN OF THE TRUSS NG SET. ER TO BCI-B1 FOR COMPLETE CTION AND SAFETY PROCEDURES. SUPPORT ANY PLANT SHELVES