Loading...
HomeMy WebLinkAboutSITE PLANI '� 'EXISTING FIRE HYDRANT cj� ::E 189' EXISTING 8" WATER MAIN W FIT GRAPHIC SCALE 0 0 10 20 40 8 IN FEET I inch = 20 ft. PROPOSED SITE DATA COMPONENT ACRES SO FT. % OF SITE PROPOSED BUILDING 0.14 5,933 6.5 PROPOSED PAVING 0.23 10,037 21.9 w, W W INDUSTRIAL 27TH STREET EXISTING. AQDWAI T (80' R/W) PROPOSED 1 " WATER 3: SERVICE PROPOSED SIGN PROPOSED �D PROPOSED 2',,,,�IN WALL NOO ' 47'10" W EXISTING 4" R 366,00' FORCE MAIN-\ 5' CONC WALK STOP BAR & PROPOSED FM FM FM STOP SIGN 6' CIL FENCE (OVERALL) IB3.00 S R/W LINE </ F:PR OPO SI\El D _F7A �r � PROPOSED :!L�j = = = = = � T�7 I\ Tj n A �R ME \-ST LU CIE CO, AIRPORT-) ST LUCIE BLVD Li Li 27.. DETENTION AREA FM- (YPOSED 6� 1 WALL \-PROPOSED 59.33' CBS PROPOSED 2" FM PROPOSED 4(TYP) GAT PUMP STATION < U) 16" PINE* < _WS " I < PROPOSED <Icn Ld 5933 SF --- -0 �0' '00 1-STORY 0 a_ T _,cn < BUILDING CD Di < 19" PI�E 26' PROPOSED < (TYP) <' Z 5' CONC WALK I \ \ �' \ \ \ \ \ PROPOSED LOADING ZONE misc. 0.03 1,336 2.9 LOCATION MAP POND 0.05 2,201 2.4 NOT TO SCALE <; PROPOSED CONC. IMPERVIOUS 0.40 17,306 37,7 (1+2+3 ABOVE) 23" PINE 0 DRIVE AND�PARKING OPEN SPACE 0.65 28,627 62.3 <' TOTAL SITE AREA 1.05 45,933 100.0 11 16" PINE* ZL <' 13.5 10,0 (AUSTRALIAN) GENERAL NOTES 59 3 3' 1, PROJECT NAME: DOYLE PROPERTIES, LLC INDUSTRIAL 27TH STREET - CD -0 p 0 2. LOCATION: SECTION 29, TOWNSHIP 34 SOUTH, RANGE 40 EAST m 1 11 PROPOSED FORT PIERCE, FLORIDA P L-n DUMPSTER .00 00 ENCLOSURE LOT 8 3. OWNER: DOYLE PROPERTIES, LLC P.O. BOX 12339 FORT PIERCE, FLORIDA 34979 LOT 9 </ 4. APPLICANT DOYLE PROPERTIES, LLC j, PROPOS - E D CONC. P.O. BOX 12339 (F I FbRT PIERCE, FLORIDA 34979 -QUIPMENT/VEHICILE/ -,MAT§RIAL, STORAGE-) 5. ENGINEER: ATLANTIC CIVIL ENGINEERING, INC. PROPOSED- 50', PROPOSED 2552 PETERS ROAD SUITE D IRRIGATION - FORT PIERCE, FLORIDA 34945 WELL 0 PROPOSED SILT PHONE: (772) 398-1520 PROPOSED--'� 4 FENCE AND 8' OPAQUE I N LIMITS OF CLEARIN( 6. SURVEYOR: LAVENTURE & ASSOCIATES, INC, FENCE OR WALL I Q 2552 PETERS ROAD u I I r- u -s FORT PIERCE, FLORIDA 34945 S PHONE: (772) 398-6430 7. DESCRIPTION: LOT 8, AIRPORT INDUSTRIAL PARK UNIT ONE REPLAT, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 20, PAGE 3, OF THE PUBLIC RECORDS OF El L ST. LUCIE COUNTY, FLORIDA. 10 --)1, 1 50' NATIVE S E TL� A: -1, VEGETATION BUFFER �nACT --1 - -- - UVVINE F-,: I r\ L /� j �' F\ L- - - - - PINE - - - - - - - FOOD BANK,INC. --4---16" 'M7(AUSTRALIAN) EXISTING ZONING: IL 3' 13 L D G 8. PARCEL ID NO: 1429-502-0008-0007 LAND USE:IND s E TE3,A,- 9. TYPE OF PROJECT: MASONRY CONSTRUCTION OFFICE 183.00' 10, PROJECT SIZE: 45,933 SO FT. (1.06 ACRES) GROSS AREA \��PROPOSED LOT 11 6' CIL FENCE 11. BUILDING SIZE: 5,933 SO FT. (0.14 ACRES) LOT 10 OWNER: JOHN LANGELI ET AL EXISTING ZONING: IL 12. FUTURE LAND USE: IND (INDUSTRIAL) LAND USE:IND IN ni I C7DI A I /Q T I I (-I P COLIN TY) 13. EXISTING LUNIN U: IL �L-I�n I 14. FLOOD ZONE: ZONE X 15. PARKING: REQUIRED 8 SPACES PROVIDED 8 SPACES 16. DEVELOPMENT BEGIN CONSTRUCTION: APRIL, 2018 SCHEDULE: CONSTRUCTION TO BE COMPLETED: 180 DAYS 17. UTILITY SERVICE: WATER SERVICE FORT PIERCE UTILITIES AUTHORITY SEWER SERVICE FORT PIERCE UTILITIES AUTHORITY 18, SITE I DRAINAGE: THE STORMWATER MANAGEMENT SYSTEMS WILL CONSIST OF DETENTION AREAS WITH AN OUTFALL TO THE ROADSIDE SWALE AND WILL BE DESIGNED PER ST. LUCIE COUNTY AND SOUTH FLORIDA WATER MANAGEMENT DISTRICT CRITERIA. PARKING DATA USE I ITE CODE RATE(PER 1,000 SF) SF SPACES OFFICE 701 2.84 1987 (5.64) 6 SPACES WAREHOUSING 150 0.50 3946 (1.97) 2 SPACES TOTAL M Q TE Ld CD - 0 CD 1 -C, P 1 P L-0 I 0) CN 00 z 8 SPACES REVISION S- By DATE PLAN A -'TIE DOYLE PROP] ' R S LLC 71 5 B I D G SETBACK SOO*47'1 O"E EXISTING 8" WATER MAIN 182' - = FIRE HYDRANT W- DRIVEWAY - WITHIN R/W TO BE CONSTRUCTED WITH PHASE 1 5' .00, R/W LINE LOT 7 '10' BLDC LOT 6 --TBACK C OWNER: TONAKI, LLC EXISTING ZONING: IL >1< LAND USE: IND x- 183.00' X - - - - - - - 366.00' LOT 12 LOT 13 (OVERALL) OWNER: WARREN HEIM CORP. EXISTING ZONING: !L LAND USE:iND TRAFFIC STATEMENT ITE LAND USE GENERAL LIGHT INDUSTRIAL �X = 40 EMPLOYEES AVG.) DAILY TRIP GENERATION T = 2.95 (X) + 30.57 149 TRIPS AF-IRLPTV AM PEAK TRIP GENERATION T = 0.27 (X) + 70.47 82 TRIPS (68/IN AND 14/OUT) Cm m PM PEAK TRIP GENERATION T = 0.29 (X) + 58.03 70 TRIPS (15/IN AND 55/OUT) BY DATE DRAWN JOE M 10/24/17 DESIGNED RCL 11/10/17 CHECKED RCL 11113117 QA/OC RML 11/14/17_ SURVEY IREF. DRAWING NAME i�.m66 201 7-m§ I SITE -PLAN DATE: 3/23/18 J013 No. 2017-0109 ATLANTIC CIVIL ENGINEERING, INC. HORIZ SCALE: 1"=20' - SHEET 2 OF 8 CONSULTING ENGINEERS VERT SCALE: N/A 41 2552 PETERS ROAD SUITE D 3" FORT PIERCE, FLORIDA 34945 (772) 398-1520 PHONE (772) 398-1521 FAX CERTIFICATE OF AUTHORIZATION #32020 1 EXISTING 8" EXISTING WATER MAIN FIRE HYDRANT ------------ - -------- W ---------------------------- \ - ------- - ----- w ----------------------------------------- -- ----- w ---------------- -------------------------------- W, - ------------------------------- -------- w ----------------- ----------------------------------------------------- w ----------------------------------------------------------------------------------- W ------------------------------------------------- F__�� --------- L I - PROJECT BENCHMARK FND PKID 2391 _T' EL=17.06 (NAVD 1988) ON �� 1. INDUSTRIAL 27TH !STREET - - - - - - - - - - - ------ I - - - - - - - C - - - - - - - - - - 70-N-ST. MATCH X. ASPHALT -- CONC. MATCH EX. ASPH�� CONC HEADER HEADER CURB CONST 47 L F PROP, M,E.S. CONST. 14 L.F. PROP. M.E.S. INV, 15,10 LL CONST, 47 L.F. OF 14" x 23" rr�url VI.F.3. INV. 15.05 INV PROP. V,E.S. INV. 14.95 1 E S OFF 14" x 23" 15 00_--� INV. 15.00 R.C.P. @ 0.05% C P @ 0 "5'. i OF 15" R.C.P' & = SD-4 M. E. S. PROPOSED R.C.P. @ 0.05% CONST, 15" R.C.P \zo x 15.20 '\ ' - - - - - - - - INV. 5' C-ON C�K_ - ----------------- MA\bl -------------- INV. 16.00 7 A 'N� - v_X_ N6, R/W LINE NOO'47'1 0"W A 00' 1 �82 0 1LLOI/ 1=8 2OX= 17 SD-5 7.. Z PRO .0 D CONTROL DRY D AREA PR 'No DRY D E &I fO AREA 11 - STRUCTURE 7.0 SEE DETAIL </ SHT. 5 OF 7 4 4 CONST. 54 L. F SD-2 OF 15" R C P CONST. 15" R.C.P_// 59.3 17' �7j @ 0.0 % M. E. S. SD-3 CONST. 15" R.C.P 18.. 0 INV, = 16,25 19; 72 CONST. 145 L.F. OF 15" R.C.P. @ 0.24% LOT 9 (VACANT) 0-0 5 Ln 00 0 PROPOSED DUMPSTER SD_l ENCLOSURE CONST. 15" R.C.P M. E. S. INV. = 16.60 ------------ LOT 10 FFE=17.67 M. E. S. INV. = 16.00 19.2 </ </ < </ OFFICE </ ------------- ---------------------- ---- 20 'CD WAREHOUSE 0 0 14� <1 41 0 6 6 �72 0 19. 2 </ </ Z� PROPOSED </ 1 4 5' CONC WALK PROPOSED 5933 SF A <1 4�, </ RROPOS D 15 X 30'' A 1-STORY LOADING</ZONE BUILDING <i r\l\r� F.F.E. = 19 50' 4� </ </ LO T 8 < �19 4-2 N 59.33' D =CURB </ 19.42 19. Q TYP) (TYP) </ If.5b, 4� Z� Op OSED CONIC. DRWE AND p AI�I�ING </ THICK) ,(6" <1 </ 41 /C </ 1 .50 1& <18.50 z 6.2 PERIMETER BERM MIN. ELEV. 18 15 161.4 �A - , . , . I -� PROPOS��D CONC.' (,EdUj,I3MENT/VETI X91RAGE-) �MA7�RIAL_,, 9 1, ;plf. 2� 16.8 17�O 16.8 -- ------------------------------ 50' NATIVE VEGETATION BUFFER PERIMETER BERM MIN. ELEV, 18. 15 -PROPOSED 6' CL FENCE IYAW60 LOT 11 FFE=18.77 SOO-47'10"E 366.00' (OVERALL) PAVING, GRADING AND DRAINAGE PLAN DOYLE PROPERTIES, LLC b �'z '0�y LOT 7 183.00' LOT 12 FFE=19.16 -PROPOSED 6' CIL FENCE Ld CD P L-n 0) N co z LOT 6 (VACANT) ---------------------- LOT 13 FFE=18.21 R E V I S 1 0 N S BY DATE BY DATE DRAWN JOE M 10/24/17 DESIGNED RCL 11/10/17 CHEC�ED RCL 11/13/17 QA/QC RML 4/4/18_ ... SURVEY REF, IDRAWING NAME .. . . . ........... .. . 17,3066 mi 1--di bg GRAPHIC SCALE 20 0 10 20 40 IVA] ( IN FEET ) 1 inch = 20 ft. 71 z STORMWATER MANAGEMENT CRITERIA SUMMARY (1988 NAVID LOT #8 CONTROL ELEVATION 15�00 MINIMUM ROAD CROWN EL. 17.73(0.44 C.F.S.) 10 YEAR - 1DAY STORM 6.5 INCHES RAINFALL MINIMUM PERIMETER EL. 18.15(0.79 C.F.S.) 25 YEAR - 3 DAY STORM 10.8 INCHES RAINFALL MINIMUM FINISHED FLOOR EL, 19.50(19.15) 100 YR, 3 DAY, 0 DISCHARGE 12.911 INCHES RAINFALL EXISTING ELEVATIONS 8.2,0/ PROPOSED ELEVATIONS ATLANTIC CIVIL ENGINEERING, INC. CONSULTINC ENGINEERS 2552 PETERS ROAD SUITE D FORT PIERCE, FLORIDA 34945 (772) 398-1520 PHONE (772) 398-1521 FAX CERTIFICATE OF AUTHORIZATION #32020 DATE: 3/23/18 HORIZ SCALE: 1"=20' VERT SCAUF- N/A ARID M. JOB No, 2017-0109 OB SHEET 3 OF 8 Cr 'EXISTING FIRE HYDRANT a N FT] GRAPHIC SCALE 10 20 40 ( IN FEET ) 1 inch — 20 ft. 189' 182'---- CONSTRUCT 1" EXISTING 8" DOUBLE STRAP SADDLE WATER MAIN FIRE HYDRANT EXISTING 8" & I" CORP STOP W_ —W WATER MAIN W_ W z V) 3;: 27TH STREET - - - - - - - - - - - - - - - - - EXISTING ASPHALT -INDUSTRIAL (80' R/W) CONSTRUCT P ROPOSED SIGN D RIVEWAY CONSTRUCT 2" DOUBLE STRAP SADDLE 138 LF OF ILL V) 1" P.E. WATER 3: IN WALL CONSTRUCT WITHIN R/W TO & 2" CORP STOP ONSTRUCT SERVICE 70 LF OF 6" N00-47'I 0"W BE CONSTRUCTED so EXISTING 4" PROPOSED 1 BFP W/ PROPOSED Ic PVC GRAVITY 366.00' WITH PHASE 1 FORCE MAIN h 5' CONIC WALK 5/8" METER STOP BAR & STOP SIGN ((4 1/8" PER FOOT) (OVERALL) FM FM- 11 FM SERVICE (LOT 7) (CAP ENU) x — 183.00' R/W LINE R/W LINE X A_x — ss 183.00' </ CONSTRUCT"� LF OF PROPOSED Z-� PROPOSEDA­---� 115 27. DETENTION AREA DETENTIO N REA 2" PVC FM ONS RUCT 2 >1 CONSTRUCT-\ 45' BEND </ 2" FM 17m — — ___7 — — OSED PROPOSED 5 9_3 3' CBS WALL PROPOSED CONSTRUCT_,__� 2" FM PROPOSED 26' 1�kTYP) GAT 2" PVC FM UNDER 15" RCP W/ PUMP STATION CONSTRUCT \��PROPOSED 12" MIN. SEPARATION CONSTRUCT CLEANOUT (7YP) 28 LF OF 6" 6' CIL FENCE PVC GRAVITY SERVICE WS < 20' < n o. En > CD 0 0 CD Z� < PROPOSED �, � I Y�-) I 5' CONC WALK:\ LOADING ZONE </ PROPOSED 5933 SF PROPOS D CON C. 1—STORY BUILDING 3.5 10. 0 0 59.33, 0 -C) 00 Ln 1 0 4�</ 0 U-) > \y 00 P, Ln J, PROPOSED jz ) DJMPSTER 00 1 00 < ENCLOSURE LOT 8 LOT 7 Cn LOT 9 < </ LOT 6 A PROPOSED CONC. TF, (EQUIPMENT/VEHICIL�/ MAT I A L 8TOR AGE-) 50', 0 PROPOSED >< 4 IRRIGATION C\� WELL lo, B-- SETB�ALI\ C C 50' NATIVE OWNER: TONAKI, LLC VEGETATION BUFFER EXISTING ZONING: IL OWNER: TREASURE COAST ---- — — — — — — — — — — — — — — — — LAND USE: IND FOOD BANK, INC. EXISTING ZONING: IL _) RI In - LAND USE:IND 183.00' X — — — — — — — X SOO*47'10"E ,-PROPOSED LOT 11 366.00' LOT 12 LOT 13 6' CIL FENCE (OVERALL) LOT 10 OWNER: JOHN LANGEL, ET AL OWNER: WARREN HEIM CORP. EXISTING ZONING: IL EXISTING ZONING: IL LAND USE:IND LAND USE: IND R E V I S 1 0 IN S BY DATE UTILITY PLAN DOYLE PRI16OPEIRTIES, LLC BY DATE DRAWN JOE A 10/24/17 DESIGNED RCL 1 1/10/17 CHECKED RCL 11/13/17 OA/QC RML 4/4/18 SURVEY REF, IDRAWING NAME 17.3006 2017-0109 SITE -PLAN ATLANTIC CIVIL ENGINEERING, INC. CONSULTING ENGINEERS 2552 PETERS ROAD SUITE D FORT PIERCE, FLORIDA 34945 (772) 398-1520 PHONE (772) 398-1521 FAX CERTIFICATE OF AUTHORIZATION #32020 DATE: 3/23/18 1 JOB No. 2017­0109 HORIZ SCALE: 1'=- �20'::j SHEE I T - N � 4 OF 8 VERT SCAI F A 11 CHARD V. LAVYKO _W P.E. No. 34288 DATE JJ 0, Rwnd Clerneld "Y It CI; f. Sleb, 3' 0, �J'Tftldk, I � R=adWIM WWF SAS-Wl.401,4 500� ____ �, f /� — I TOP VIEW -SINGLE PIPE 3 1 iA , Ike 0 p r al E g. lk For led cnrc,et' Pipe 51d, DIW z/z L: ...- J�lnj -4 111k B, The EnII 5150 *5I.A., h4 Mile,, T. ��P�. F., ffp.s 18" And 5.1101. hi? r Idea 24 And LaMer. )r �P. 0,N.0 S'IPIPV To Be Invaded Under Unll P000 F11 Uttered End Seeflen) 42 Td f Pl,. F�, P?R*A 0' And Smehe, SEC TION hl FAr PIPeA 24" And Larger. 15 R.C.P. MITERED END SECTION 1 12" PAVEMENT SECTION � 1 1/2"R BASE A SUBGRADE #4 BARS CONT. J NOTE: ALL CURBS TO BE SAWOUT 0 5' INTERVALS, 12" HEADER CURB TOP OF BERM EL.= 18.15 MIN, EXISTING GRAD 3:1 3:1 MAX, MAX. MINIMUM PERIMETER BERM TOP EL,= 17.0- TOP EL.= 1&00 Do EL.= 17.0-18.15 `-� BOTTOM EL.= VARIES 16.0-17.0 TYPICAL SWALE SECTION IES (SEE PLAN 41 PROPOSED sOD MAX. MAX. DRY DETENTION SECTION TCP EL.= 18.00 USF Frame and Grate as Indicated, For Traffic Areas use USF 4155-6209. For Non -Traffic Areas use USE W/ -;,Bar -Can't, 6210. 2 1/2"x2 1/2"x1/4" Angle w/ 3/16"xl"x6" Anchor Welded 0 6" O.C� Grout min 18" if Precast Pavement & 3,-1 Backfill d 4, 1 P PE SIZE TYPE AND INVERT AS INDICATED ON PLAN SHEETS 1T T SUMP� .117 8" Concrete w/ No. NOTES: 4 Bare At 12" 0 C� 1. Construct Type "C" Inlet per FDOT Index #232. TYPICAL TYPE "C" INLET R=2' Type "D" Curb NOTES: �. Use 3,000 P,S,I. concrete at 28 days for construction, 2. Subgrade to extend an additional 6" beyond Type 'D" Curb. 3. Type "D" Curb to be constructed in accordance with FDOT Index #300. TYPE I'D" CURB VARIES Provide 1/8" to 1/4" contraction /joints at 5' centers (max), 'Compact Subgrade to 98% of the Maximum Density as Determined by AASHTO T-99 NOTES: 1. Use 3,000 P.S.I. Concrete At 28 Days for sidewalk construction. 4 THICK SIDEWALK DETAIL Backfill For Storm Sewer To Be Uniformly Deposited and Compacted In Accordance With FDOT Standard Specifications Section 125-83 Latest Edition 12" --�IP20D� 2" Desig r Grade rSide Slop 'e To Be No F[atter Than Necessary To stall To I Pipe Shope To Receive Bell For R.C.P. 1/2 Pipe Diameter For C.A.P. STORM PIPE BEDDING DETAIL 20' 26' PARKING TRAVEL 77 MIN F- TYPICAL PAVEMENT DETAIL (1) CONSTRUCT 6" THICK CONCRETE (3,000 PSI MIN.) W/ FIBREMESH 0 1/5 LB PER CY 12" STABILIZED SUBGRADE (COMPACTED MIN. 98% OF AASHTO T-180) (LBR 40 MIN.) SECTION A -A, TYPICAL PAVEMENT SECTION PAVING, GRADING, AND DRAINAGE DETAILS DOYLE PROPERTIES FILTER FABRIC TO EXTEND 8" MiN. FROM GRATE SIDES I PREDOMINATE FLOW, 4" L PARKING STALL _"""�IWHEEL STOP 7 PLAN #4 BAR #4 DOWEL FOR ANCHORING-\ 5 1 -8" LONG 2 REQUIRED 7" L 4P-C)" 1.-0. 5P_0P, FRONT ELEVATION SECTION PRECAST CONCRETE WHEEL STOP METAL INLET GRATE FILTER FABRIC TI CONTINUE UNDER ENTIRE GRATE, "A 4, 4 PICTORIAL VIEW GENERAL NOTES 1. THIS INLET IS DESIGNED WITH FILTER FABRIC PROTRUDING 8" FROM SIDES FOR GRIPPING WHEN SEDIMENT NEEDS TO CLEARED AFTER FINAL CONSTRUCTION. 2. FILTER FABRIC TO BE INSTALLED AND TRIMMED BEFORE GRATE IS INSET. FILTER FABRIC DETAIL EDGE OF PAVEMENT 24" STOP BAR PAINT 4't6 30' MAXIMUM 6' to 12' 24"x24" TYPICAL — S P UNLESS OTHERWISE NOTED I 6'tol 2 TYPICAL STOP SIGN LOCATION DETAIL 5 1/2 4" SYMBOL SHALL BE PAINTED WITH WHITE PAINT AND TO THE DIMENSIONS SHOWN HANDICAP SYMBOL PAINT DETAIL R E V I S 1 0 N S BY DATE BY DATE DRAWN JOE M 10/27/17 DESIGNUD PC 1 0/20/17 CHECKED RCL I 1 /03/17 QA/QC RML 4/04/18 SURVEY REF. NAME 17 3006 �DRAWING 2016-ID� HANDICAP S111 BLUE WHEEL STOP WHEEL STOP BLUE\ BLUE BLQe BLUE L=�j FTP 25 WHITE NOTES: 1. TOP PORTION OF FTP 25 & 26 SHALL HAVE A REFLECTIVE BLUE BACKGROUND WITH WHITE REFLECTIVE SYMBOL AND BORDER. BLUE 2� BOTTOM PORTION SHALL HAVE A REFLECTIVE WHITE BACKGROUND W TH BLACK OPAQUE LEGEND AND BORDER. 3. FTP 25 & 26 MAY BE FABRICATED ON ONE PANEL OR TWO, r 4. FTP 25 IS FOR USE IN AREAS WHERE BLUE/� BLUE SPACE IS LIMITED. 5. PLEASE REFER TO FDOT INDEXES #17346 AND #17355 FOR THE LATEST HANDICAP PERMANENT MARKINGS AND HANDICAP SIGN DETAILS. HANDICAP SPACE DETAIL FTP-26 WHITE ON BLUE PARKING BY BLACK ON WHITE FILTER FABRIC TO EXTEND DISABLED 1,-� W/ 1 1/2 " LETTERS I" ­­ 1 10 ROM GRA7 SIDES PERMIT DRY DETENTION BOTTOM EILEV� = 16�O ONLY BLACK ON WHITE 250 FINE S, 318,14 7- 12' MIN, FTP=55 A POST 4, , 4 IN 4- L -.4 "12� HANDICAP PARKING SIGN PLAN VIEW 4 " YlEIR WALL INLET TOP T.0 N. EL = 8.15 ELEVATION 19 DO — TOP AEIR ELEVATION 18 15 — M 'HIGH "DE WEIR ELEV. 70112.1.-Mi _ELEVATON 17.50 DRYVIDEIIENITIO� BOTTOM ELE 60 12' I OPENING, V'RC I 5"ROP '. D' EILIEEIEA� PIPE INVERT ELEV 15 20 STRUCWRE --BOTTOM MUEV. 15.0 CONST. 3" DIA. — BLEEDER 0 EL-15.4 SECTION A -A SECTION B-8 CONTROL STRUCTURE DETAIL ATLANTIC CIVIL ENGINEERING, INC. CONSULTING ENGINEERS 2552 PETERS ROAD SUITE !D FORT PIERCE, FLORIDA 34945 (772) 398-1520 PHONE (772) 398-1521 FAX CERTIFICATE OF AUTHORIZATION #32020 mommommommo� - MODIFIED `r(PE 'C" INLET DETENTON EL = 16.0 DATE: 3/23/18 111JOS No,2017-01091 HORIZ SCALE: 1"--40' SHEET 5 OF 8 VERT SCALE- N/A I 11i Ille" I MAIGNEVC WIRE AFF?XED BY IDENTIFICATION TAPE (TYP-) POLYETHYLENE TUBING SERVICE EXISTING WATER MAIN CORPOR47TON DRY —CON-,, I —STOP CONNECTMOR L �­THHN WINE N APE T ROL ME TU91NO SE C ISIING WATER N 0 Z To R Rlk7 N I. STAINLESS STEEL DOUBLE AFMAP SERVICE SlIDDLE " ROME ME ME" Box r sox 04" "Rg M NY CONTRACTOR FINISHED GRAVE METING SEE NOTE #1 MjINTO E INST WATER ANN LOCKABLE METER VALVE 7ON STOP (NOTE 5) COURS STOP COR10IM4101 FORD PART I 841—XXXK-0) 774NN WINE WITH ONE SHOT LOCK (STERLING SECURITY SYSTEM STAINLESS STEEL DOUBLE dR-05) STRAP SEROCE SADDLE Bj2ys.. W17H I.P. THREAD 1. BLUE 10 GAUGE THHN WIRE SHALL BE ATIACHED TO THE SERME LINE, 2 WHERE SERVICES UNDER PAVEMENT ARE REQUIRED THE POLYETHYLENE TUBING SHALL BE INSIXLLED WITHIN SCHEDULE 40 Pvc CASING PIPE. J. I - & 314 - METER SIZES SHALL REQUIRE A LOCK48LE METER VALVE. (CURB STOP) 4. MINIMUM COVER IN UNPAVED AREAS SHALL HE 30, IN FAVIED AREAS OR PLANNED R040WAYS OR SHALES MIN. COVER SNAU BE 36'. S. MR 2' COMMERCAL SERVICE INSTALLATIONS, FPUA WILL INSTALL ABOVE GROUND METER PER DE?XJL W­& TYPIr,4L SINGLE WATER SERVICE CONNEC770 (N. T. S.) TYFICAL SINGLE WATER SERVICE CONNEI W-2 WA�W�� Fr PIERCE VMJW AUTHORITY wm S� - "T"Y C(5: 7� 1 UFA Now WATER SERVICE DETAIL SEE N07E /5 PIPELINE PLAN VIEW SwRvr VCR PIPE PVC UNKA in PYPAUNE PROFILE VIEW TYPICAL 4" OR 6' WASTEWATER SERVICE - 0200 AMRI OWE AOHHNf O)'Rlak) Raw `sEXL.mV OR INsEprA—im WASTEWATER PIPE &ADDLE OR APPROVIED EQUAL NO INSERTA—TEE'S ARE NOT TO BE USED DURING NEW CONSTRUCTION. %#fNrA—TEES ARE ONLY APPROVED FOR INSTALLATION ON 24' AND OCR SEW MAINS. 1) RQAAAO SADDLE SHALL BE USED AS A TEMPLATE FOR DETERMINING HOLE 0129 AND LOCATION. 4) 0200 MARINE GRADE ADHESIVE SHALL HE USED TO SE& ROM14C GASKET TO UNIX 5) SIAL EXPOSED LINER TO VCR WTTH HYDRAULIC CEMENT 6) ENSURE TO FOLD STRAP BACK AGAINST ITSELF PLACING FREE' END REFWM STRAP AND PIPE ON SMALL PIPF, IT MAY BE NECESSARY TO FOLD END TWICE. WASTEWATER SEROCE DETAI (FOR UNED SEWER AMIN (N.T.S.) WASTEWATER SERVICE DETAIL 2 112' RIA.C. SIX BAD W W/ 3/,s' OUTLET OR APPROM 1I 314- P.Vr SM 40 p p A� OR COPPER FIRE "PANT BRALL \ VALVE 0 FIORD CURB S70P 7 7/77'" I' POLYE7HYLEPE SERVICE LINE NOTE PLEASE REFER TO FORT PIERCE UTiLTiES STANDARD SEPARATION STATEMENT FOR WATER / SEWER CONFLICTS, UTILITY CROSSING DETAIL N.TS. �)T/L/TY CROSSING DETAIL M-5 rob WAMS60STE�TERIGAS ENCINEERING _j p 2,X)602 DKI .+1 F LJw 'A"AF— $NEU, j— lic PQIQ i UTILITY CROSSING DETAIL FINISH GRADE SEE NOTE NO. 5 12" INITIAL BACKFILL EMSEOMEA SPRING MATERIAL LINE HAUNCHING 11 OF PIPE BEDDING,,"' MIN IF RE IRED FOUNDATION ji (MAY NOT HE REQUIRED) BACKFILLING REQUIREA,IF'NITS MTS NOTES: 1) IN CERTAIN SOIL CONDITIONS A FOUNDATION MAY BE REQUIRED. 2) BEDDING IS REQUIRED PRIMARILY TO BRING THE TRENCH BOTTOM UP TO GRACE, BEDDING MATERIALS SHALL PROVIDE A UNIFORM AND ADEQUATE LONGITUDINAL SUPPORT UNDER THE PIPE. 3) HAUNCHING MATERIAL SHALL BE HAND PLACED TO THE SPRINGUNE OF THE PIPE, MATERIAL SHALL BE CONSOLIDATED UNDER THE PIPE AND HAND TAMPED TO PROVIDE ADEQUATE SIDE SUPPORT. 4) INITIAL SACKFILL MATERIAL SHALL BE HAND PLACED TO 12" ABOVE THE TOP OF PIPE, THE SOIL SHALL BE COMPACTED TO 1007 MAX, DENSITY,(AASHTO T-99) 5) BACKFILL SHALL BE COMPACTED TO 100% OF MAX. DENS17Y AS PER AASHTO T-99, TO A POINT 30" BELOW PROPOSED PROFILE GRADE OR EXISTING GRADE, THE FINAL 30" OF OACKFILL SHALL BE COMPACTED TO 98% OF MAX. DENSITY AS PER AI T= 160. 6) DENSITY TEST SHALL BE PERFORMED AT AREAS DETERMINED BY THE OTILITIES ENGINEER OR PERMIT AGENCY HAVING JURISDICTION, AT THE CONTRACTORS EXPENSE, 7) CONTRACTOR TO COMPLY WITH ALL FEDERAL, STATE AND LOCAL TRENCH SAFETY REGULATIONS. STANDARD SEPARATION STATEMENT FOR WATER / SEWER CONFLICTS 1. SANITARY SEWER, FORCE MAINS, AND STORM SEWERS SHOULD CROSS UNDER WATER MAINS WHENEVER POSSIBLE, SANITARY SEWERS, FORCE MAINS AND STORM SEWERS CROSSING UNDER WATER MAINS SHALL BE LAID TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 6 INCHES, PREFERABLY 12 INCHES BETWEEN THE INVERT OF THE UPPER PIPE AND THE CROWN OF THE LOWER PIPE WHEN ABOVE, AND AT LEAST 12 INCHES OF SEPARATION WHEN THE WATER MAIN IS BELOW WHERE SANITARY SEWER, FORCE MAINS, STORM SEWERS MUST CROSS A WATER MAIN WITH LESS THAN a INCHES VERTICAL SEPARATION, BOTH THE SEWER AND WATER MAIN $HALL BE CONSTRUCTED OF DUCTILE IRON PIPE (DIP) CENTERED ON THE CROSSING, (DIP 19 NOT REQUIRED FOR STORM SEWERIII SUFFICIENT LENGTHS OF DIP MUST BE USED TO PROVIDE A MINIMUM SEPARATION OF 10 FEET BETWEEN ONTS, ALL JOINTS ON THE WATER MAIN WITHIN 20 FEET OF THE CROSSING MUST BE MECHANICALLY RESTRAINED, &L CROSSINGS SHALL BE ARRANGED 50 THAT THE SEWER PIPE JOINTS AND WATER MAIN PIPE JOINTS ARE COUIOISTANT FROM THE POINT OF GROSSING PIPES CENTERED ON THE CROSSIN06 AT SUCH CROSSINGS PIPES §HA4=L 99 ARRANGED 50 THAT ALL WATER MAiN JOINTS ARE AT LEAST THREE Fff FROM ALI- 40INTS IN VACLI SANITARY SEWERS, STORM SEWER% §TORMWATRR FORCE MAINS, OR PIPELINIIA; CONVEYING RIECLoMMED WATER REGULATING UNDER PART III OF CHARTER 62-510, FAO,� AND AT LEAST SIX FEET FROM ALL JOINTS IN GRAVITY OR PRIESSURE TYPE SANITARY SEWERS, WASTEWATER FORCE MAIN% OR PIPELINES CONVEYING RECLAIMED WATER NOT REGULATED UNDER PART III OF CHARTER 52=010, F*C� WHERE A NEW PIPE CONFLICTS WITH AN EXISTING PIPE WITH LESS THAN 6 INCHES VERTICAL CLEARANCE, THE NEW PIPE IIHALL BE CONSTRUCTED OF DIP (EXCEPT STORM SEWERS) AND NEW PIPES SHALL BE ARRANGED To MEET THE CROSSING REQUIREMENTS ABOVE, 2 A MINIMUM 3=FOOT HORIZONTAL SEPARATION SHALL BE MAINTAINED BETWEEN A& TYPE OF STORM SEWER AND WATER MAIN IN PARALLEL INSTALLATIONS WHENEVER POSSIBLE, A MINIMUM 3—FOOT� AND PREFERABLE 10=FOQT HORIZONTAL SEPARATION SHALL BE MAINTAINED BETWEEN YACUUM TYPE SANITARY SEWER AND WATER MAIN IN PARALLEL INSTALLATIONS WHENEVER P05910LE. A MINIMUM 10—FOOT HORIZONTAL SEPARATION SHALL BE MAINTAINED BETWEEN "ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM" AND WATER MAIN IN PARALLEL INSTALLATIONS WHENEVER POSSIBLE, A MINIMUM 6—FOOT, AND PREFIERABLE IO=FGGT HORIZONTAL SEPARATION SHALL BE MAINTAINED BETWEEN GRAVITY OR PRESSURE TYPE SANITARY SEWER, WAOTEWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER AND WATER MAIN IN PARALLEL INSTALLATIONS WHENEVER POSSIBLE. THE MINIMUM HORIZONTAL SEPARATION DISTANCE BETWEEN WATER MAINS AND ORAVITY—TYPE SANITARY SEWERS SHALL BE REDUCED TO 3 FOOT WHERE THE BOTTOM OF THE WATER MAIN 15 LAID AT LEAST SIX INCHES ABOVE THE TOP OF THE SEWER IN CASES WHERE IT IS NOT POSSIBLE TO MAINTAIN A 10—FOOT HORIZONTAL SEPARATION, THE WATER MAIN MUST BE LAID IN A SEPARATE TRENCH OR ON A UNDISTURBED EARTH SHELF LOCATED ON ONE SIDE OF THE SEWER OR FORCE MAIN AT SUCH AN ELEVATION THAT THE BOTTOM OF THE WATER MAIN IS AT LEAST a INCHES ABOVE THE TOP OF THE SEWER, WHERE IT IS NOT POSSIBLE TO MAINTAIN A VERTICAL DISTANCE OF 8 INCHES IN PARALLEL INSTALLATIONS. THE WATER MAIN SHALL BE CONSTRUCTED OF DIP AND THE SEWER OR THE FORCE MAIN SHALL BE CONSTRUCTED Or DIP (EXCEPT STORM SEWER) WITH A MINIMUM VERTICAL DISTANCE OF 6 INCHES, THE WATER MAIN SHOULD ALWAYS BE ABOVE THE SEWER. JOINTS ON THE WATER MAIN SHALL BE LOCATED AS FAR APART AS POSSIBLE FROM JOINTS ON THE SEWER OR FORCE MAIN (STAGGERED JOINTS). 3 ALL DIP SHALL BE PRESSURE CLASS 250 MIN_ ADEQUATE PROTECTIVE MEASURES AGAINST CORROSiON SHALL BE USED AS DETERMINED BY THE DESIGN ENGINEER. STANDARD SEPARATION STATEMENT LIMIT OF UTILITIES AUTHORITY INSTALLATION PLAN TEE FOR TESTING NIPPLE W WATER METER APPROVED BACKFLOW A TER El?, ASSEMBLY 6" NIPPLE 6" NIPPLE 90' ELBOW--_,,� 90' ELBOW 2" LOCKABLE 2" CORPORATION CORPORATION 2 LOCKIN " LOCKING 29 I TEST PORT METER FLANGE CURB STOP TEST PORT � FINISHED GRADE PRonLE 2 " COPPER _�, SERVICE PIPE NOTES 1 LANDSCAPING REQUIRED PER CITY OF FORT PIERCE OR ST. LUCIE COUNTY ORDINANCE. NO PLANTS OR TREES WITHIN 18" AROUND METER OR BACKFLOW NO SOLDER JOINTS, 2, ASSEMBLY TO BE 29" FROM FINISH GRADE TO CENTERLINE OF THE FLANGED 90' SENO� WATER METERIBACKFLOW EREVENtM ASSLMaY DOMESTIC SERVICE =A4MFRQAj (A(,T.§,) BACKFILLING REQUIREMENTS WATER METER/BACKFLOW PREVENTER BACTERIOLOGICAL SAMPLING POINT ASSEMBLY DOMESTIC SERVICE (COMMERCIAL) WATER AND SEWER DETAILS DOYLE PROPF LLC .RTIES, R E V I S 1 0 N S — BY DATE BY DATE DRAWN, JOE, M 10�217/17 DESIGNED. R. C.L. 1 0/?O/l 7 CHECKED RCL 11/03/17 QA/QC RML 4/04/18 SURVEY REI DRAWING NAME 17 3006 2016-0034-POD ATLANTIC CIVIL ENGINEERING, INC CONSULTING ENGINEERS 2552 PETERS ROAD SUITE D FORT PIERCE, FLORIDA 34945 (772) 398-1520 PHONE (772)398-1521 FAX CERTIFICATE OF AUTHORIZATION #32020 DATE: 3/23/18 HORIZ SCALE: 1"-4F� RICHARD M JOB No,2017-0109 SHEET 6 OF 8 VA #34288 ATE I NEMA 3R TYPE 304SS DUPLEX ELECTRICAL CONTROL PANEL TO INCLUDE EMERGENCY GENERATOR RECEPTACLE, LIGHTNING ARRESTOR, SURGE ARRESTOR, MAIN BREAKER, EMERGENCY BREAKER, PUMP BREAKERS, MOTOR STARTERS WITH THERMAL OVERLOAD PROTECTION, HIGH WATER ALARM LIGHT WITH HORN, SILENCE AND TEST, HOA SWITCHES, RUN LIGHTS, NON—RESETTABLE ELAPSED TIME METERS, AND DUPLEX ALTERNATIING CONTROL SEQUENCE AS A MINIMUM. BOTTOM OF CONTROL PANEL TO BE MOUNTED AT/ABOVE 100 YEAR FLOOD ELEVATION PANEL TO MANUFACTURED AND LABELED IN ACCORDANCE WITH UL STANDARD FOR SAFETY 508A EYS CONDUIT SEAL (TYP. OF 3) ALUMINUM BASIN COVER W/FLOODTIGHT 24' X 36" HINGED ACCESS DOOR 2" CONDUIT AS MANUFACTURED BY u 'v' H �OD T' F LHINGED A ESS CC A S M AN U FA C TU R (TYP. OF 3) USF FABRICATION 2" SCH80 PVC VENT ASSEMBLY W/SS SCREEN 0 TOP A 0 GRADE 48" DIAMETER FIBERGLASS 2" ADAPT —A —FLEX REINFORCED CONDUIT FITTING WET WELL (TYPICAL OF THREE) ]TYPE 104SS LIFTING "J" INLET FITTING CHAIN FIELD INSTALL BY OTHERS INLET INVERT HIGH WATER ALARM "D" LEGEND FT NGVD A TOP ELEVATION 19.50 B GRADE ELEVATION 19.00 T-INLET INVERT ELEVATION 1 16,00 T INLET INVERT ELEVATION 2 13.00 D ALARM FLOAT ELEVATION 13.00 T LAO FLOAT ELEVATION 12.50 F LEAD FLOAT ELEVATION /ATION IT 7yc_) ION 8.50 -I— ,I I INIFT PIPF SIZE ___ ALUMINUM VALVE VAULT COVER W/FLOODTIGHT 24" X 36" HINGED ACCESS DOOR AS MANUFACTURED BY USF FABRICATION 316SS TOP RAIL SUPPORT (BOLTS TO NUT RAIL) T 2 QU'C K QU 0 D S SCONNIEC W/C ST C W DUST CA CCJ A 2" RESILlf SEAT GA VALVE �--2" RESILIEPT SEAT GAT$ VALVE II 2" CAST IRON BALL CHECK VALVE � ED � 13 1 o I cl � ffm��Illm BM BE 31 B2 HORN HORN I PANDUTT E7MI 0 PLI ETME ]SILENCE 0 OLL1 PL2 'SILENIE LT CD (D OILL2 E E PON Swl a OSFI swa a OLL3 OSF: OR R4 OLL4 cm TEST cz MOD DEAD FRONT BACKPANEL LIGHTNING ARRESTOR MOUNTED ON BACKPANEL BEHIND BREAKER FRAME SURGE ARRESTOR MOUNTED ON BACKPANEL BEHIND BREAKER FRAME BILL OF MATERIALS BM/BE MAIN/EMERG BREAKERS SQUARE D QDU330 BI/B2 PUMP BREAKERS SQUARE D QOU320 BC CONTROL BREAKER SQUARE D QDU115 BIR RECEPTACLE BREAKER SQUARE D QCU115 REC DUPLEX RECEPTACLE PASS & SEYMOUR 1591-1 GR GENERATOR RECEPTACLE PYLE NATIONAL JRE4100PR LA LIGHTNING ARRESTOR DELTA M0603 SA SURGE ARRESTOR DELTA CA603 PM PHASE MONITOR DIVERSIFIED SLA230AS,A Sl/S2 PUMP STARTERS TELEMECANIQUE LCID1810 30" X 40" FIBERGLASS OIL THERMAL OVERLOAD RELAY TELEMECANIQUE LR2DI314 AL ALARM LIGHT INGRAM LRX-40 REINFORCED VALVE VAULT HORN ALARM HORN EDWARDS 87OP-N5 SIL SILENCE CONTROL CONCEPTS P34 TEST ALARM TEST CARLING 6FA54-73 Ri DPDT RELAY OMRON MK2P-Sl20VAC ALT ALTERNATOR DIVERSIFIED ARA120ABA MODE ALTERNATOR MODE SWITCH CARLING 2GE54-73 SWI/2 HAND -OFF -AUTO SWITCH CONTROL CONCEPTS SS03 ETMI/2 ELAPSED TIME METER GRASSLIN FWZ-72 PLI/2 PILOT LIGHT CONTROL CONCEPTS FVLU120GNT P1_4-9 PUSH -TO -TEST PILOT LIGHT CONTROL CONCEPTS FVPTT120-IPBCRD OSFI/2 OIL SEAL FAIL LIGHTS LITTELFUSE 970-67OA-92WRN XFMR 120X24 TRANSFORMER MICRON B05OLP7JK FU FUSE BUSSMAN FNM-2 36" R2-5 DPDT RELAY EIMRON LYR-24VAC ENO P4NEL ENCLOSURE RONNEI 3RSI/142411 WITH 3 POINT DOOR LATCH DISCHARGE GRINDER SYSTEM CONTROL -PANEL LEVEL —,l 11 SCH40 TYPE 304SS GUIDE PIPE �2" SCHBO PVC DISCHARGE PIPE LAG PUMP ON "E"_ MYERS PUMP MODEL WGL20 —23 SUBMERSIBLE GRINDE� PUMP RATED 2HP, 2,30\i, 3—PHASE, 60HZ DUTY: 28 GPM @ 73 FT TDH LEAD PUMP ON F PER ENGINEER OF RECORD SRA125 LIFT —OUT PUMPS OFF "G" ---MYERS RAIL ASSEMBLY SERVICE METER A 0 NEMA 4X SQUARE-D MODEL H321DS SERVICE RATED FUSED DISCONNECT BOTTOM 3/4" HOSE BIBB W/RPZ BACKFLOW DEVICE 12' STAINLESS -STEEL STRAPS FEEDERS & CONDUIT 1 # 6 IN 3/4" CONDUIT GRINDER PUMP STATION DETAILS 1. A —UV SCH. 80 P.V.C. THERM-0-WELD 2" SCH80 PVC UNION (TYPICAL OF THREE) 2" CAST IRON BALL CHECK VALVE (TYPICAL OF TWO) 2" BRONZE RESILIENT SEAT GATE VALVE (TYPICAL OF THREE) 2" SCH80 PVC PIPE TYPICAL THROUGHOUT 2" SCH80 PVC ELBOW (TYPICAL OF THREE) 2" SCH80 PVC CROSS (TYPICAL OF ONE) I FINISH GRADE 4 I ELECTRICJ TRANSFORMER i_��3/4" x 8' COPPER GROUND ROD REAR VIE HIGH L VEL ALA LIGHT VISIBLE FROM ALL DIRECTIONS NEMA 3X - 24" x 24" x 8" STAINLESS STEEL CONTROL PANEL �RIGID GALVANIZED CONDUIT �CONDUIIT SEAL OF TO BE PLACED WITHIN 18" OF K ELECTRICAL ENCLOSURE. PROVIDE 10' x 25 x 6"--/ (3 - 1 1/2" REQUIRED) CONCRETE PEDESTAL WITH #4 BAR 12" O,C. E.W. NEMA 4X-6" x 6" x 24"STAINLESS STEEL WEATHERPROOF JUNCTION BOX WITH TERMINAL STRIP \—FINISH GRADE 4 1 WET WELL TRANSFORMER 90' 7SWEEP (SEE NOTE 1) i '. � =:��PROVIDE THREE SEPARATE CONDUITS FOR TO ELECTRIC MOTOR CABLES AND LIQUID LEVEL REGULATOR CABLES. CONDUIT SHALL BE SIDE VIEW SCH 80 PVC 1-1/2". NOTES: 1. PEDESTAL MUST BE LOCATED A MINIMUM OF 4 FEET FROM THE WET WELL. 2 CONTROL PANEL CAN BE MOUNTED TO BUILDING WALL, PER OWNER'S DISCRETION. PANEL MUST BE WITHIN 50 Fr. OF STATION. CONTROL PANEL PEDESTAL (OPTIONAL) 120 VAC M Go 1 9 10 6 0 PLI 7 OL MAIN $1 IDISCONNECT R5 2 R moo THERM ETM TO BE LI PROVIDED _4 4' a ) BY OTHERS R4 5 13 L2 :5) L3 ALT R2 17 R ALARM LIGHT R'l HORN !GH _EEl:EI_ .1 �l I Is KE� I - SILENCE 21 TEST R, 62 KOHMS TOTAL RESISTANCE 22 OSF1 ­v�� e- 62 KOHMS TOTAL RESISTANCE XFMR 2 AMP 20 �2 34 38 WIRE COLOR CODE (#,CLR) 0 - BLACK 1 - BROWN 2 - RED 3 - ORANGE 4 - YELLOW 5 - GREEN 6 - BLUE I PUMPT OFF 7 - PURPLE 0 0 8 - GRAY TEST 9 - WHITE CONTROL PANEL SCHEMATIC 9 SECURE TO PIPE SUPPORT WITH TWO STAINLESS STEEL HOSE CLAMPS 75/4" REDUCED PRESSURE BACKFLOW �REVENTOR (BY CONTRACTOR) BALL VALVE WITH TEST COCK (TYPICAL) SEE NOTE #2 SEE NOE #I- 3/4" HOSE BIBB FINISH GRADE 2" GALVANIZED SUPPORT PIPE FILLED WITH CONCRETE NOTES 1. 1" POLYETHYLENE TUBING SDR 9 COPPER TUBE SIZE, 2. LANDSCAPING REQUIRED PER CITY OF FORT PIERCE OR ST. LUCIE COUNTY ORDINANCE. NO PLANTS OR TREES WITHIN 18" AROUND METER & BACKFLOW. NO $OLDER JOINTS. HOSE BIBB W/RPZ BACKFLOW PREVENTER R E V I S 1 0 N S 13Y DATE LIFT STATION AND WATER & SEWER DETAILS DOYLE PROPERTIES, LLC BY DATE DRAWN JOE M 10/27/17 DESIGNED ROL 10/20/17 CHECKED ROL 11/03/17 QA/QC RML 4/04/18 SURVEY REF, NAME 17.3006 IDRAWING, 2016-0034-PGID BM PT2 208/23OV, 3 PHASE, 60 HZ Ll - 115V TO GROUND 91 I T -E -y I I -y -y 7 1 44 44 TI T2 T3 Tl T2 T3 \-i-/ Qmi M2 L 9.5 FLA 9,5 FP A 0 2H 2 HIP PM SIR 30 TO CONTROL NOTES I � PANEL MUST BE GROUNDED IN ACCORDANCE WITH LOCAL, STATE, AND NATIONAL CODES 2 A GROUNDED SYSTEM NEUTRAL MUST BE SUPPLIED (GROUNDING TO BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE ARTICLE 250) 3) USE COPPER CONDUCTORS RATED 60deg C IF RATED LESS THAN 100 AMPS; 75de&C IF RATED 100 AMPS OR MORE 4� ALL NDUITS MUST ENTER FROM BOTTOM 5 TERMINAL TiGHTENING TORQUE REQUIREMENTS FOR NEUTRAL, GROUND AND INCOMING POWER CONNECTIONS ARE AS FOLLOWS: 35LB-IN FOR #18-#10AWG; 40LB-IN FOR 6) #BAWG; AND 45LB-IN FOR #6-#4AWG ERMINAL TIGHTENING TORQUE REQUIREMENTS FOR #18AWG PUMP CONTROL CABLES AND FLOATS ARE 20LB-IN 7) MAIN & EMERGENCY BREAKERS ARE MECHANICALLY INTERLOCKED TO PREVENT SIMULTANEOUS OPERATION 8) GENERATOR POWER REQUIREMENT IS 7KW CONTINUOUS OUTPUT WITH 30 AMPERE RATING @ 208/23OV, 3 PHASE, 60HZ, CONTROL PANEL SCHEMATIC Pm a rl ILE Copy, r MOUNT BRONZE DISC WITH VALVE NOMENCLATURE VALVE BOX & COLLAR USF # 7635 WET 3" POLYETHELYNE CAM LOCK ASS'Y WEE\ I I W/ VENTED AIR RELEASE 8 MAk G'MIN. 120 fle,F 11 P\2' GALVANIZED NIP LE SCHEDULE 80 PVC NIPPLE 45' PVC BENDS 2" RESILIENT SEAT GATE VALVE�/ SECTION A -A PUMPOUT CONNECTION ATLANTIC CIVIL ENGINEERING, INC. CONSULTING ENGINEERS 2552 PETERS ROAD SUITE D FORT PIERCE, FLORIDA 34945 (772) 398-1520 PHONE (772) 398-1521 FAX CERTIFICATE Of AUTHORIZATION 02020 DATE: 3/23/18 JOB No.2017-01 HORIZ SCALE: 1" = 411 L ___7 _�SHEET 7 OF 8 'A . VERT SOLE N /7A M. LAbYR757, P/ #34288 DATE � 4 1 , , . . � , I . � . I SUPPLEMENTARY CONDITION PERMITS AND LICENSES: CONSTRUCTION PERMITS FOR CERTAIN ELEMENTS OF THE PROJECT WORK HAVE BEEN OBTAINED OR APPLIED FOR BY THE OWNER, AND THE DESIGN AND CONSTRUCTION REQUIREMENTS OF THE PROJECT REFLECT CONSTRAINTS AND CONDITIONS IMPOSED BY THESE PERMITS. THE CONTRACTOR SHALL PERFORM HIS WORK AND SHALL CONSTRUCT THE PROJECT IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PERMITS AND APPROVALS, COPIES OF WHICH ARE AVAILABLE FOR His REVIEW AND USE FROM THE ENGINEER, UPON REQUEST. THE CONTRACTOR SHALL SECURE ALL WORK PERMITS, APPROVALS OR LICENSES REQUIRED TO PERFORM THE WORK, AND HE SHALL PERFORM THE WORK IN STRICT ACCORDANCE WITH THOSE PERMITS, APPROVALS OR LICENSES, CONTRACTISSUE GENERAL CONDITIONS: UNLESS OTHERWISE STATED IN THESE SUPPLEMENTARY CONDITIONS, THE PROVISIONS OF THE "STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT," REFERENCED ABOVE. SHALL BE USED TO GOVERN ALL ISSUES ADDRESSED IN THOSE GENERAL CCNDITIONS FOR THIS PROJECT. OWNER -ENGINEER RELATIONSHIP: ANY AGREEMENT BETWEEN OWNER AND ENGINEER SHALL NOT BE CONSTRUED TO PROVIDE ANY OBLIGATION FROM THE ENGINEER TO ANY THIRD PARTIES INCLUDING, BUT NOT LIMITED TO, ANY CONTRACTORS (GENERAL OR SUB), NOR TO ANY SUCCESSORS IN TITLE TO THE OWNER. THE RIGHTS UNDER ANY AGREEMENT BETWEEN OWNER AND ENGINEER INURE ONLY TO THOSE TWO PARTIES. PARTIAL PAYMENTS: PARTIAL PAYMENTS SHALL BE CALCULATED FROM QUANTITIES OF WORK IN PLACE, THESE PAYMENTS SHALL BE BASED ON THE AGREEMENT UNIT PRICES AND WILL BE MADE ON OR ABOUT THE 15TH OF EACH MONTH FOR THE PREVIOUS MONTH'S PROGRESS. THE CONTRACTOR SHALL, AFTER THE FIRST OF EACH MONTH, SUBMIT INVOICES FOR MATERIALS USED AND WORK PERFORMED FOR THE PREVIOUS MONTH. THE ENGINEER WILL REVIEW ALL INVOICES ALONG WITH RECORD DRAWINGS AND FIELD NOTES TO DATE BEFORE PRESENTING THEM TO THE OWNER FOR PAYMENT. TEN PERCENT (10%) OF THE AMOUNT DUE AND PAYABLE TO THE CONTRACTOR WILL BE RETAINED FROM EACH PARTIAL PAYMENT, FINAL PAYMENTS WILL BE ACCOMPLISHED AS PRESCRIBED IN THE AGREEMENT. - 104 "m Tybtufli: ERRORS OR OMISSIONS IN THE DRAWINGS OR SPECIFICATIONS: PRIOR TO INITIATION OF THE WORK, THE CONTRACTOR SHALL CHECK DIMENSIONS, GRADES, ELEVATIONS AND THE SUMMARY OF ESTIMATED QUANTITIES SHOWN ON THE DRAWINGS TO ASSURE HIMSELF THAT THEY ARE CORRECT AND THAT THE WORK CAN BE ACCOMPLISHED AS INTENDED, THE CONTRACTOR SHALL TAKE NO ADVANTAGE OF ANY APPARENT ERROR OR OMISSION WHICH HE MIGHT DISCOVER, BUT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF SUCH DISCOVERY, WHO WILL THEN MAKE SUCH CORRECTIONS AND INTERPRETATIONS AS HE DEEMS NECESSARY FOR REFLECTING THE ACTUAL SPIRIT AND INTENT OF THE DRAWINGS AND SPECIFICATIONS, SOIL AND SUBSOIL CONDITIONS: IT 15 THE SOLE AND EXCLUSIVE RESPONSIBILITY OF THE CONTRACTOR TO: 1, PLACE HIS OWN INTERPRETATION ON ANY AND ALL SOIL AND SUBSOIL DATA PORTRAYED ON THE DRAWINGS OR THIS PROJECT MANUAL, 2. PERFORM HIS OWN SOIL AND SUBSOIL INVESTIGATION TO DETERMINE THE NATURE, CHARACTER, LOCATION AND EXTENT OF ALL SOIL AND SUBSOIL CONDITIONS THAT MAY AFFECT HIS WORK; AND 3. INCLUDE IN HIS CONTRACT PRICE CONSIDERATION FOR ALL WORK NECESSARY TO ASSURE THAT THE SOIL AND SUBSOIL CONDITIONS WILL MEET THE REQUIREMENTS OF THE SPECIFICATIONS AND THE APPLICABLE REGULATIONS OF THE CITIES OF ST. LUCIE WEST PORT ST, LUCIE AND ST. LUCIE COUNTY. THE WOR PRE -CONSTRUCTION CONFERENCE: IMMEDIATELY AFTER THE AGREEMENT HAS BEEN AWARDED, THE ENGINEER SHALL CALL A PRE -CONSTRUCTION CONFERENCE TO BE HELD WTHIN FIFTEEN (15) CALENDAR DAYS AFTER THE AWARD AND PRIOR TO INITIATION OF THE WORK AT A PLACE DESIGNATED TO Him, TO REVIEW THE CONSTRUCTION ASPECTS OF THE PROJECT, THE MEETING WILL BE BETWEEN THE ENGINEER, OWNER AND THE CONTRACTOR. THE CONTRACTOR SHALL PRESENT HIS TENTATIVE DETAILED WORKING SCHEDULE FOR THE PROJECT SO THAT IT MAY BE REVIEWED BY THE ENGINEER AND OWNER. ADDITIONALLY, IT WILL AFFORD THE CONTRACTOR AN OPPORTUNITY TO HAVE ANY QUESTIONS HE MAY HAVE ON THE WORK CLARIFIED BY THE ENGINEER. NO WORK UNDER THE AGREEMENT SHALL COMMENCE UNTIL AFTER THE NOTICE TO PROCEED HAS BEEN ISSUED. COMMENCEMENT AND COMPLETION OF THE WORK! THE CONTRACTOR SHALL COMMENCE WORK UNDER THE AGREEMENT WITHIN TEN (10) CALENDAR DAYS AFTER THE DAY OF RECEIPT BY HIM OF THE NOTICE TO PROCEED AND SHALL COMPLETE THE WORK READY FOR USE NOT LATER THAN THE TIME INDICATED IN THE AGREEMENT THE TIME STATED FOR COMPLETION SHALL INCLUDE FINAL CLEANUP OF THE PREMISED. ESTIMATED QUANTITIES: THE QUANTITIES ESTIMATED FOR VARIOUS ITEMS OF WORK ARE ONLY ESTIMATES, AND MAY NOT REFLECT ALL THE ITEMS OF WORK OR THE FINAL QUANTITIES NEEDED TO COMPLETE THE PROJECT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DO ALL WORK AND To FURNISH AND INSTALL ALL IMPROVEMENTS SHOWN ON THE DRAWINGS, WHETHER OR NOT THEY ARE SHOWN IN THE ESTIMATED QUANTITIES, OR WHETHER THE FINAL QUANTITIES ARE MORE OR LESS THAN THOSE ESTIMATED. HORIZONTAL AND VERTICAL CONTROL: THE CONTRACTOR SHALL CONSTRUCT THE REQUIRED IMPROVEMENTS IN THE LOCATIONS SHOWN ON THE DRAWINGS, AND SHALL USE AS HORIZONTAL CONTROL POINTS THE EXISTING PROPERTY CORNERS AS SHOWN ON THE PLANS, THE HORIZONTAL CONTROL POINTS WERE PROVIDED BY LAVENTURE AND ASSOCIATES, INC., (772-398-6430). AS VERTICAL CONTROL, BENCHMARKS SHALL BE PROVIDED AT THE SITE, FOR USE IN ESTABLISHING THE NECESSARY ELEVATIONS AND GRADES AT THE LOCATIONS SHOWN ON THE PLANS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT ALL CONTROL POINTS AND TO REESTABLISH SAID POINTS AS NECESSARY. REMAINING HORIZONTAL AND VERTICAL CONTROL WORK SHALL BE PERFORMED BY THE CONTRACTOR THE VERTICAL CONTROL POINTS FOR THIS PROJECT WERE PROVIDED BY LAVENTURE AND ASSOCIATES, INC., (772-398-6430). COORDINATION OF WORK NTH OTHERS: THE CONTRACTOR SHALL COORDINATE HIS WORK WITH THE WORK OR IMPROVEMENTS OF OTHERS WITH REGARD TO NEW CONSTRUCTION, OR FOR THE NEED OF REMOVAL, RELOCATION OR ALTERATION OF EXISTING FACILITIES. THIS INCLUDES, BUT IS NOT LIMITED To, THE OWNER, SOUTHERN BELL TELEPHONE & TELEGRAPH, TCI UNITED ARTISTS CABLE VISION COMPANY, ST. LUCIE COUNTY UTILITIES, CENTRAL FLORIDA CELLULAR PHONE COMPANY, ST. LUCIE COUNTY ENGINEERING DEPARTMENT AND THEIR CONTRACTORS, SUBCONTRACTORS OR AGENTS. STANDARDS FOR QUALITY AND WORKMANSHIP: ALL MATERIALS, EOUIPMENT AND SUPPLIES FURNISHED BY THE CONTRACTOR FOR PERMANENT INCORPORATION IN THE WORK SHALL BE NEW AND OF THE QUALITY STANDARDS SPECIFIED. WORKMANSHIP SHALL BE FIRST-CLASS AND THE FINISHED PRODUCT EQUAL TO THE BEST ACCEPTED STANDARDS OF THE TRADE FOR THE CATEGORY OF WORK PERFORMED. � TEMPORARY UTILITIES: ALL ARRANGEMENTS AND COSTS FOR TEMPORARY POWER, WATER AND WASTEWATER FACILITIES DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, I OBSERVING THE WORK: THE PROGRESS AND QUALITY OF THE WORK WILL BE OBSERVED BY THE OWNER'S ENGINEER OR ENGINEER'S APPOINTED EMPLOYEE, NO OBSERVER IS AUTHORIZED TO CHANGE ANY PROVISIONS OF THE SPECIFICATIONS WITHOUT WRITTEN AUTHORIZATION OF THE OWNER'S ENGINEER, NOR SHALL THE PRESENCE AND/ OR THE OBSERVER RELIEVE THE CONTRACTOR FROM ANY REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS. THE CONTRACTOR SHALL GIVE THE ENGINEER A MINIMUM OF 24 HOURS NOTICE PRIOR TO REQUIRED INSPECTIONS, AND SHALL SUPPLY ALL EQUIFMENT NECESSARY TO PROPERLY TEST AND INSPECT THE COMPLETED WORK. IN ADDITION TO THE REQUIREMENTS FREVOUSLY REFERENCED, THE FOLLOWING MINIMUM CONSTRUCTION CONTROL CHECKPOINTS SHALL BE ADHERED TO, AND THE CONTRACTOR SHALL NOTIFY THE ENGINEER FOR OBSERVATION: 1. PRIOR TO ANY DEVIATION FROM THE DRAWINGS: . 2. PRIOR TO ANY BACK FILLING TRENCHES CONTAINING HYDRAULIC CONDUITS, SO THE I JOINTING MAY BE INSPECTED; 3. PRIOR TO TESTING OF ALL HYDRAULIC CONDUITS. . 4. PRIOR TO PLACEMENT OF ROADWAY BASE MATERIAL, CONCRETE OR ASPHALTIC CONCRETE. 5. UPON COMPLETION OF CONSTRUCTION FOR FINAL INSPECTION WITH THE CONTRACTOR OR HIS REPRESENTATIVE, TESTING: IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE INDEPENDENT TESTING LABORATORY DESIGNATED BY THE OWNER, THE TESTING AND PLIANCE WITH THE SPECIFICATIONS. COST FOR THE INITIAL TESTING SHALL BE BORNE BY THE OWNER. ANY RETESTS REQUIRED DUE TO FAILURE TO MEET THE MINIMUM REQUIREMENTS SHALL BE PERFORMED AT THE E RACTOR. THE NAME OF THE OWNER'S TESTING LABORATORY SHALL BE SUPPLIED AT THE PRE CONSTRUCTION MEETING. EXISTING UTILITIES AND STRUCTURES: EXISTING UTILITIES, CILITIES SHOWN ON THE DRAWINGS WERE LOCATED AS ACCURATELY AS POSSIBLE FROM THE RECORDS EXAMINED. NO GUARANTEE IS MADE THAT ALL EXISTING FACILITIES ARE SHOWN OR THAT THOSE SHOWN ARE ENTIRELY ACCURATE. THE CONTRACTOR SHALL ASSURE HIMSELF OF THE ACTUAL LOCATION OF THE UTILITIES, STRUCTURES OF FACILITIES PRIOR TO PERFORMANCE OF I ANY WORK IN THE VICINITY. THE UTILITY COMPANIES OR UTILITY AGENCIES WILL COOPERATE WITH THE CONTRACTOR IN LOCATING UNDERGROUND UTILITIES THAT MAY BE SUBJECT TO DAMAGE OR INTERRUPTION OF SERVICES DURING THE CONTRACTOR'S OPERATIONS. PRIOR TO START OF THE WORK, THE CONTRACTOR SHALL REQUEST THAT EACH UTILITY AGENCY ADVISE HIM OF THE LOCATION OF THEIR FACILITIES IN THE VICINITY. THE OWNER WILL ASSUME NO LIABILITY FOR DAMAGES SUSTAINED OR COSTS INCURRED BECAUSE OF THE CONTRACTOR'S OPERATION IN THE VICINITY OF EXISTING UTILITIES OR STRUCTURES, OR TO THE TEMPORARY BRACING AND SHORING OF SAME. IN THE EVENT THAT IT IS NECESSARY TO SHORE, BRACE, OR SWING A UTILITY, THE UTILITY COMPANY OR DEPARTMENT AFFECTED SHOULD BE CONTACTED AND THEIR PERMISSION SECURED AS TO THE METHOD USED FOR ANY SUCH t WORK. . RES-TORATION OF DAMAGED STRUCTURES OR UTILITIES: IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR, REBUILD OR RESTORE TO ITS FORMER CONDITION, ANY AND ALL PORTIONS OF EXISTING UTILITIES, STRUCTURES, EQUIPMENT, APPURTENANCES OR FACILITIES, OTHER THAN THOSE TO BE PAID FOR UNDER THIS CONTRACT, WHICH MAY BE DISTURBED OR DAMAGED DUE TO THIS CONSTRUCTION OPERATION, AT NO COST TO THE OWNER. FINAL CLEANUP: UPON COMPLETION OF THE WORK BUT BEFORE FINAL PAYMENT WILL BE MADE, THE CONTRACTOR SHALL CLEAR AND REMOVE FROM THE PROJECT AREA, ALL FALSE WORK, EQUIPMENT, SURPLUS AND DISCARD MATERIALS, RUBBISH AND TEMPORARY STRUCTURES WHICH RESULT FROM THE WORK UNDER THIS AGREEMENT, AND SHALL RESTORE IN AN ACCEPTABLE MANNER ALL PROPERTY WHICH HAS BEEN DAMAGED DURING THE PROSECUTION OF THE WORK. RECORD DRAWINGS: AFTER COMPLETION OF THE CONTRACT WORK, BUT PRIOR TO SUBMITTAL FINAL PAYMENT, THE CONTRACTOR SHALL PROVIDE ALL INFORMATION OR PREPARATION OF FINAL RECORD DRAWINGS FOR SUBMITTAL TO THE OWNER OF THE COMPLETED IMPROVEMENTS, THE INFORMATION SHALL INCLUDE FINAL LOCATION, BY REFERENCE TO COMPLETED IMPROVEMENTS, OR OTHER ACCEPTABLE MEANS, OF ALL UNDERGROUND OR SUBMERGED IMPROVEMENTS, THE ELEVATIONS OF PERTINENT POINTS IN THE DRAINAGE, WATER AND WASTEWATER SYSTEMS, ACTUAL CONSTRUCTED PIPE LENGTHS, SLOPES AND INVERTS, CUTOFF WALL DIMENSIONS AND ELEVATIONS, ALL REVISIONS TO THE ORIGINAL PLANS, AND ALL INFORMATION NECESSARY TO LOCATE AND OPERATE THE IMPROVEMENTS CONSTRUCTED UNDER THIS AGREEMENT. PAYMENT FOR OBTAINING AND PROVIDING THE RECORD DRAWING INFORMATION SHALL BE INCLUDED IN THE CONTRACT UNIT PRICES FOR THE VARIOUS ITEMS OF WORK TO WHICH IT IS INCIDENTAL, THE CONTRACTOR SHALL COORDINATE THE CONSTRUCTION, SO THAT THE ENGINEER'S -I'. REPRESENTATIVE IS PRESENT AND CAN CONFIRM THE RECORD INFORMATION AS FOLLOWS. 4 THE FINAL LOCATION, B� REFERENCE TO AT LEAST TWO COMPLETED VISIBLE IMPROVEMENTS OR OTHER PERMANENT POINTS, OF ALL PAVING, DRAINAGE, WATER DISTRIBUTION SYSTEM AND WASTEWATER COLLECTION SYSTEM ELEMENTS, AND SHALL INCLUDE ELEVATIONS OF PERTINENT POINTS IN TE PAVEMENT AND DRAINAGE IMPROVEMENTS, ALL REVISIONS TO THE ORIGINAL PLANS, VERIFICATION OF ALL DESIGN DIMENSIONS, ELEVATIONS, PIPE SLOPES, PIPE LENGTHS AND ALL OTHER INFORMATION NECESSARY TO HORIZONTALLY AND VERTICALLY LOCATE AND OPERATE THE IMPROVEMENTS CONSTRUCTED UNDER THIS CONTRACT. INFORMATION TO BE SHOWN FOR THE WATER DISTRIBUTION SYSTEM INCLUDES THE LOCATION SERVICE TERMINALS, FOR THE WASTEWATER COLLECTION SYSTEM INCLUDES THE LOCATION OF ALL SERVICE TERMINALS, AND THE LOCATION OF ALL ELECTRICAL AND COMMUNICATION CONDULT. DRAWINGS SHALL INCLUDE: A. ANY CHANGES OR VERIFICATIONS GET MARKED B. MARK OUT ALL "PROPOSED" OR "CONSTRUCTS" C, CHANGES TO LOCATIONS OF PIPE, VALVES, FITTINGS OR MANHOLES, ETC, D. DRAW IN A DETAIL BOX OF ANY SUBSTANTIAL CHANGES E. MARK LOCATIONS AND FOOTAGE OF ALL LATERALS FROM THE DOWNSTREAM MANHOLE F. MARK ALL BSP'S ON PLANS GUARANTEE: ALL MATERIALS AND THE INSTALLATION THEREOF WHICH ARE FURNISHED AND INSTALLED BY THE CONTRACTOR, UNDER THE TERMS OF THE AGREEMENT, SHALL BE GUARANTEED BY THE CONTRACTOR AGAINST DEFECTIVE WORKMANSHIP, MECHANICAL AND PHYSICAL DEFECTS, LEAKAGE, BREAKAGE, AND OTHER DAMAGES AND FAILURE UNDER NORMAL OPERATION FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL PAYMENT, SAID DATE TO CONSTITUTE THE COMMENCEMENT OF THE ONE (1) YEAR WARRANTY PERIOD. ALL MATERIALS AND INSTALLATIONS PROVING TO BE DEFECTIVE WITHIN THE SPECIFIED PERIOD OF THE GUARANTEE SHALL BE REPLACED, WITHOUT COST TO THE OWNER, BY THE CONTRACTOR. THE PERIOD OF GUARANTEE OF EACH SUCH REPLACEMENT SHALL BE FROM AND AFTER THE DATE IN INSTALLATION THEREOF, MATERIALS, CONSTRUCTION METHODS, TESTING AND TOLERANCES FOR ALL WORK SHALL I BER IN ACCORDANCE WITH THE FOLLOWING SPECIFICATIONS. IN THE EVENT OF A CONFLICT, THE MORE STRINGENT PROVISION SHALL APPLY, 1. MOBILIZATION: THE WORK SPECIFIED IN THIS SECTION CONSISTES OF THE AND OPERATIONS IN MOBILIZING FOR BEGINNING WORK ON THE PROJECT, INCLUDING, BUT NOT LIMITED TO, THOSE OPERATIONS NECESARY FOR THE MOVEMENT OF PERSONNEL, EQUIPMENT, SUPPLIES AND INCIDENTALS TO THE PROJECT SITE, AND FOR THE ESTABLISHMENT OF TEMPORARY OFFICES, BUILDINGS, SAFETY EQIUPMENT AND FIRST AID SUPPLIES, SANITARY AND OTHER FACILITIES. AS REQUIRED BY THESE SPECIFICATIONS, THE SPECIAL PROVISIONS, AND STATE AND LOCAL LAWS AND REGULATIONS. ALL COSTS FOR BONDS, PERMITS AND ANY REQUIRED INSURANCE, AND ANY OTHER PRECONSTIRCUTION EXPENSE NECESSARY FOR THE START OF THE WORK, AS WELL THE COST OF THE REMOVAL OF THE ABOVE ITMES, SHALL ALSO BE INCLUDED IN THIS SECTION. 2. CONSTRUCTION SURVEYING: THE CONTRACTOR SHALL CONSTRUCT THE REQUIRED IMPROVEMENTS AT THE LOCATIONS SHOWN ON THE PLANS. AS OUTLINED IN THE SUPPLEMENTARY CONDITIONS, THE OWNER SHALL PROVIDE BASIC REFERENCE POINTS FOR HORIZONTAL CONTROL AND BENCHMARKS IN THE VICINITY OF WORK. ALL OTHER CONSTRUCTION STAKING FOR BOTH HORIZONTAL AND VERTICAL CONTROL NEEDED BY THE CONTRACTOR FOR CONTROL OF HIS WORK SHALL BE PERFORMED BY THE CONTRACTOR. 3. CLEARING AND GRUBBING: CLEARING AND GRUB81NO SHALL BE PERFORMED WITHIN THE LIMITS OF CONSTRUCTION AS SHOWN ON THE PLANS, INCLUDING BUT NOT LIMITED TO, THE AREAS OF NEW SIDEWLAKS, SWALES, POND, ROADWAY AND PARKING PAVEMENT, AND BUILDING AREA IN ACCORDANCE WITH SECTION 110, DOR SPECIFICATION, AND SHALL CONSIST OF THE COMPLETE REMOVAL AND DISPOSAL OF ALL TREES, BRUSH, STUMPS, ROOTS, GRASS, WEEDS, RUBBISH, AND ALL OTHER OBSTRUCTIONS TO A DEPTH OF 18 INCHES BELOW NATURAL GROUND OR DESIGN GRADE, WHICHEVER IS LOWER. ALL MATERIAL SHALL BE IREN40VED FROM THE SITE OF THE PROJECT, AND SHALL BE DISPOSED OF IN ACCORDANCE WITH ALL LOCAL, REGIONAL, STATE, AND FEDERAL LAWS, REGULATIONS, AND ORDINANCES. 4. EARTHWORK AND GRADING: SHALL BE PERFORMED AS REQUIRED TO ATTAIN THE FINAL GRADES, TYPICAL SECTIONS AND ELEVATIONS, AND TO ACCOMPLISH THE OBJECTIVES SHOWN ON THE PLANS FOR THE AREAS TO BE PAVED, SODDED, OR LANDSCAPED, MATERIALS AND CONSTRUCTION METHODS SHALL MEET THE REQUIREMENTS OF SECTION 120 FDOR SPECIFICTIONS. ANIC MATERIAL WITHIN 36" OF THE FINISHED GRADE OF THE AREA TO BE PAVED SHALL BE REMOVED AND REPLACED WITH A-3 MATERIAL. EMBANKMENT ORMED IN ACCORDANCE WITH FDOR SPECIFICATIONS. ALL CLEAN EXCESS MATERIAL SUITABLE FOR FILL RESULTING FROM THE EXCAVATION SHALL BE INCORPORATED INTO THE PROPOSED WORK, OR SHALL REMAIN THE PROPERTY OF THE OWNER AND SHALL BE STOCKPILED ON THE OWNERS PROPERTY AT THE ONSITE LOCATION DESIGNATED BY THE OWNER. ALL UNSUITABLE MATERIAL AND DEBRIS SHALL BE REMOVED AND DISPOSED OF BY THE CONTRACTOR. THE WORK SHALL INCLUDE, BUT NOT LIMITED TO THE FOLLOWING: FINAL GRADING OF THE POND, SWALES, SIDEWALKS, ROADWAY, PARKING LOT, AND FILLING OF EXISTING DITCHES, 5. DRAINAGE IMPROVEMENTS: THE CONTRACTOR SHALL PROVIDE ALL MATERIALS AND O COMPLETE THE PROJECT WORK FOR THE DRAINAGE IMPROVEMENTS AT THE LOCATION, SIZE AND TYPE SHOWN ON THE PLANS FOR THE FOLLOWING ITEMS. INCLUDED IN THE UNIT COSTS FOR EACH ITEM SHALL BE THE COSTS ASSOCIATED WITH THE DESIGN AND CONSTRUCTION, BY THE CONTRACTOR, TO COMPLY WITH THE TRENCH SAFETY ACT, LAWS OF FLORIDA, CHAPTER 90-96. BACKFILL AND COMPACTION OF TRENCHINF FOR CULVERT INSTALLATION UNDER THIS SECTION SHALL BE IN ACCORDANCE WITH SECTION 125-8,3, FDOT SPECIFICATIONS. DENSITY TESTS SHALL BE PROVIDED AT THE FOLLOWING VERTICAL LOCATIONS: TWO TESTS* AT SPRINGLINE (ONE EACH SIDE OF PIPE) ONE TEST* AT ONE FOOT ABOVE PIPE; AND ONE TEST* AT ONE FOOT BELOW SUBGRADE OR FINISH GRADE. * = DENSITY OF AT LEAST 98 % OF MAXIMUM DENSITY AS DETERMINED BY AASHTO T-180 THE MINIMUM NUMBER OF HORIZONTAL TEST LOCATIONS IS TWO PER CULVERT INSTALLATION, ONE PER 100 LINEAR FEET OF PIPE AND/OR ONE PER 20 FEET OF PAVEMENT CROSSING WHICHEVER IS GREATER. ADDITIONAL TESTS MAY BE REQUIRED AT MORE FREQUENT INTERVALS IF DEEMED NECESSARY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TOO COORDINATE THE INDEPENDANT TESTING LABORATORY DESIGNATED BY THE OWNER, THE TESTING AND RETESTING NECESSARY TO ASSURE THAT THE WORK HAS BEEN PERFORMED IN STRICT COMPLIANCE WITH THESE ACTIONS. COST FOR THE INITAL TESTING SHALL BE BORNE BY THE OWNER, ANY RETEST REQUIRED DUE TO FAILURE TO MEET THE MINIMUM REQUIREMENTS ABOVE SHALL BE PERFORMED AT THE EXPENSE OF THE CONTRACTOR. GERAL LLC A. STORM SEWER PIPE: CONSTRUCTION METHODS FOR DRAINAGE CULVERTS SHALL FORT PIERCE UTILITIES AUTHORITY UIREMENTS OF SECTIONS 125 AND 430, FDOT SPECIFICATIONS. WATER DISTRIBUTION NOTES I CONTINUED REINFORCED CONCRETE PIPE (RCP): MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF SECTION 941, FDOT SPECIFICATIONS FOR STANDARD CONCRETE PIPE 16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING EXISTING UTILITIES AND DRAINAGE. DOT SPECIFICATIONS FOR GASKETS, 17. THE CONTRACTOR SHALL FURNISH RECORD DRAWING INFORMATION TO THE ENGINEER INCLUDING B. STORM INLETS: THE MATERIALS AND CONSTRUCTION METHODS FOR STORM INLETS ES, FITTINGS, SERVICE CONNECTIONS, BLOWOFFS, AIR RELEASE VALVES, AND ANY OTHER AND GRATES SHALL CONFORM TO SECTION 425, FDOT SPECIFICATIONS, PERTINENT INFORMATION NECESSARY TO LOCATE ITEMS CONSTRUCTED UNDER THIS PROJECT, As REQUIRED BY THE UTILITIES ENGINEER. TYPE "C" AND "E" INLETS SHALL BE PER FOOT INDEX NO, 232, INLETS AND PAVED AREAS SHALL HAVE STEEL GRATES SUITABLE FOR HEAVY TRAFFIC AND BICYCLES. CAST 18. THE CONTRACTOR SHALL TAP EXISTING LINES UNDER THE SUPERVISION OF THE FORT PIERCE UTILITIES IRON TRAFFIC GRATES IN ALL OTHER AREAS, I AUTHORITY ONLY AFTER TESTING AND DISINFECTION HAS BEEN COMPLETED AND APPROVED ON THE TAPPING VALVE AND SLEEVE. C. CONCRETE CURBING: THE CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS 19. WATER MAIN SHALL BE MARKED BY THE USE GAUGE THHN MULTI STRANDED WIRE (BLUE TO CONSTRUCT THE CONCRETE CURBING IN THE LOCATIONS SHOWN ON THE PLANS. ALL OF CONTINUOUS 10 CURBING SHALL BE CONSTRUCTED PER FOOT INDEX NO, 300 MATERIALS AND IN COLOR) AND IDENTIFCATION TAPE WITH "WATER" MARKED ON TAPE, PERMANENTLY ATTACHED TO THE TOP CONSTRUCTION METHODS SHALL CONFORM TO SECTION 520, FDOT SPECIFICATIONS. OF THE WATER MAIN IN ACCORDANCE WITH THE FORT PIERCE UTILITIES AUTHORITY SPECIFICATIONS. SUBGRADE UNDER ALL CURB AND GUTTER SHALL HAVE A MINIMUM LBR OF 40. 20, SERVICE TAPS SHAU BE PLACED APPROXIMATELY TEN FEET AWAY FROM GATE VALVES, AS SHOWN, FOR TESTING. FOLLOWING TESTING AND STERILIZATION OF WATER LINE. CONTRACTOR SHALL PLACE A BRASS PLUG IN CORPORATION STOPS AND CURB STOPS SHALL BE REMOVED FROM TESTING LOCATIONS. 6. PAVEMENT IMPROVEMENTS: THE CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS NECESSARY TO COMPLETE THE ITEMS OF WORK FOR PAVING IMPROVEMENTS 21. MECHANICAL RESTRAINTS TO BE USED ON ALL FITTINGS AND PLACED IN ACCORDANCE WITH UNDER THIS SECTION AT THE LOCATIONS AND TO THE EXTENT SHOWN ON THE PLANS. MANUFACTURER'S RECOMMENDATIONS AND FPUA REQUIREMENTS. PAVEMENT RESTORATION SHALL BE CONSTRUCTED AS SHOWN ON THE PLANS, AND IN ACCORDANCE WITH THESE SPECIFICATIONS, FDOT, AND ST. LUCIE COUNTY 22. ALL MAINS SHALL BE TESTED AT A MINIMUM OF 150 PSI. TESTING METHODS SHALL CONFORM TO SPECIFICATIONS. AWWA C-600. - 2 HR MINIMUM TEST A. STABILIZED SUBGRADE SHALL HAVE A MINIMUM LBR RATIO OF 40, AND MINIMUM DENSITIES SHALL BE 987 OF MAXIMUM AS DETERMINED BY THE AASHTO T-180 METHOD L= 1��2,0,51,2 C, MATERIALS AND CONSTRUCTION METHODS SHALL BE FURNISHED BY THE L= LEAKAGE IN GPH CONTRACTOR, AND CONFORM TO SECTION 160, FDOT SPECIFICATIONS FOR TYPE C STABILIZATION AND PAID FOR AS PART OF THE WORK UNDER THIS SECTION. COMPACTED S= LENGTH OF PIPE IN FEET SUBGRADE WITHIN THE LIMITS SHOWN FOR THE PROPOSED PAVEMENT SHALL BE 12 D= PIPE DIAMETER IN INCHES INCHES IN THICKNESS. STABILIZED SUBGRADE SHALL EXTEND 6 INCHES BEYOND THE RE IN PSI URSE, 7. CONCRETE NOTES: IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE INDEPENDENT TESTING LABORATORY DESIGNATED BY THE OWNER, THE TESTING AND RETESTING NECESSARY TO ASSURE THE W PLIANCE WITH THE SPECIFICATIONS, COST FOR THE INITIAL TESTING SHALL BE BORNE BY THE OWNER. ANY RETESTS REQUIRED DUE TO FAILURE TO MEET THE MINIMUM REQUIREMENTS SHALL BE PERFORMED HE CONTRACTOR, MINIMUM TESTING DETERMINATION FOR ALL ITEMS OF TE AREA SHALL BE AS FOLLOWS: FLORIDA SOIL ITEM BEARING VALUE DENSITY THICKNESS 500* 500* 100* CONCRETE ­ _. 200* *=MAXIMUM SPACING SHOWN IN FEET, ALL TESTING SHALL BE TAKEN IN A STAGGERED SAMPLING PATTERN FROM A POINT 12 INCHES INSIDE THE FIRST EDGE, TO THE CENTER, TO A POINT 12 INCHES INSIDE THE RIGHT EDGE OF THE ITEM TESTED. ADDITIONAL TESTS MAY BE REQUIRED FOR THE DRIVEWAY CONSTRUCTION OR AT MORE FREQUENT INTERVALS As BY THE ENGINEER, 8, PAVEMENT MARKINGSi THE CONTRACTOR SHALL PROVIDE ALL NECESSARY MATERIALS AND LABOR REQUIRED TO COMPLETE THE PROJECT WORK IN THIS SECTION, MATERIALS AND CONSTRUCTION METHODS FOR APPLYING PAINTED, TRAFFIC STRIPES AND MARKINGS, COMPLETE WITH REFLECTIVE GLASS APHERES. SHALL CONFORM TO THE REQUIREMENTS OF SECTION 710, FOOT SPECIFICATIONS, TRAFFIC PAINT SHALL BE APPLIED IN ALL LOCATIONS SHOWN ON THE PLANS. 9. SIGNAGE: THE CONTRACTOR SHALL PROVIDE ALL MATERIALS AND LABOR NEEDED, INCLUDING ALL SUPPORTING ELEMENTS, TO INSTALL SIGNS AT THE LOCATIONS SHOWN ON THE PLANS. MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO SECTION 700. FDOT SPECIFICATIONS, STOP SIGNS ARE TO BE HIGH INTENSITY REFERENCE PER FDOT STANDARDS, ST. LUCIE COUNTY SPECIFICATIONS AND THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES. 10. EROSION CONTROL: THE CONTRACTOR SHALL TAKE SUFFICIENT PRECAUTIONS TO PREVENT WATER POLLUTION WITH AQUATIC WEEDS, FUELS, OILS, BITUMINOUS, CALCIUM CHLORIDE OR OTHER HARMFUL MATERIALS. ALSO, HE SHALL ULE HIS OPERATIONS SO AS TO AVOID POLLUTION OR SILTATION OF WATER BODIES OR TO INTERFER WITH INDIGENOUS WILDLIFE, THE INSTALLATION OF TEMPORARY EROSION AND POLLUTION CONTROL FEATURES SHALL BE COORDINATED WITH THE CONSTRUCTION OF THE PERMANENT EROSION CONTROL FEATURES TO THE EXTENT RE ECONOMICAL, EFFECTIVE AND CONTINUOUS CONTROL OF EROSION AND WATER POLLUTION THROUGHOUT THE LIFE OF THE CONTRACT. ANY EROSION OR SHOALING SHALL BE CORRECTED BY THE CONTRACTOR AT HIS EXPENSES. DUE TO UNANTICIPATED CONDITIONS, THE ENGINEER MAY DIRECT THE USE OF CONTROL FEATURES OR METHODS OTHER THAN THOSE INCLUDED IN THE ORIGINAL CONTRACT, IN SUCH EVENT THIS ADDITIONAL WORK WILL BE PAID FOR AS RK. OD SHALL BE PROVIDED AS SHOWN ON THE PLANS, INCLUDING BUT NOT LIMITED TO, ALL DISTURBED AREAS. MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO THE REQUIREMENTS FOUND IN LANDSCAPE ARCHITECT'S SPECIFICATIONS. 11. POLLUTION CONTROL: WATER POLLUTION AND TURBIDITY CONTROL SHALL BE REQUIRED BY THE CONTRACTOR IN ACCORDANCE WITH THE DEPARTMENT OF ENVIRONMENTAL REGULATION STANDARDS, LOCAL REGULATIONS AND SECTION 104, FOOT REQUIREMENTS INCLUDING BUT NOT LIMITED TO ONE OR MORE OF THE FOLLOWING OPTIONS; SHEETPILE OR EARTH COFFERDAM, HAY BALES, SEDIMENT BASIN, SILT FENCE OR TURBIDITY BARRIER, EXCAVATED MATERIAL SHALL NOT BE DEPOSITED IN CANALS, OR IN A POSITION CLOSE ENOUGH THERETO, TO BE WASHED AWAY BY HIGH WATER OR RUNOFF. FORT PIERCE UTILITIES AUTHORITY WATER DISTRIBUTION NOTES t ALL CONSTRUCTION MATERIAL, INSTALLATION AND TESTING SHALL CONFORM TO THE STANDARD SPECIFICATIONS OF THE FORT PIERCE UTILITIES AUTHORITY. 2. WATER MAIN WHERE SPECIFIED AS POLYVINYL CHLORIDE (PVC) SHALL CONFORM TO AWWA C-900 OR C-905� PRESSURE CLASS 150, DR (18). WATER MAIN WHERE SPECIFIED AS POLYETHYLENE (PE) SHALL CONFORM To AWWA C-901 OR C-906, STANDARD CODE DESIGNATION PE3408, PIPE CLASS 200, DIMENSION RATIO (DR) 9. 3. WATER MAIN, WHERE SPECIFIED AS DUCTILE IRON PIPE , SHALL CONFORM TO ANSI A-21.51 OR AWWA C-151, AND SHALL BE PRESSURE CLASS 250 (MINIMUM). 4, POLYVINYL CHLORIDE WATER MAIN SHALL BE BLUE IN COLOR OR WHITE IN COLOR. THE USE OF IDENTIFICATION TAPE ATTACHED TO THE TOP OF THE PIPE MAY BE USED IN LIEU OF MARKING ON THE PIPE, ALSO DIP PIPE SHALL REQUIRE THE USE OF IDENTIFICATION TAPE AND THHN WIRE, 5. FITTINGS SHALL BE CAST OR DUCTILE IRON, CONFORMING TO AWWA C-110 AND ANSI A21.11, CLASS 250 MINIMUM, CEMENT LINED, AND SEAL COATED. 6. GATE VALVES SHALL BE MUELLER RESILIENT SEAT, KENNDY KEN -SEAL, AMERICAN, CLOW, OR APPROVED EQUAL, VALVES SHALL CONFORM TO AWWA C-509. 7. WATER LINES SHALL BE BACKFILLED AND COMPACTED IN ACCORDANCE WITH FPUA DESIGN AND CONSTRUCFIQN STANDARDS. THE CONTRACTOR SHALL SUBMIT CERTIFIED DENSITY TESTS AS REQUIRED BY FPUA ENGINEERING AND THE Clty, COUNTY, FOOT, IN CASES WHERE PAVED AREAS FALL WITHIN THE JURISDICTION OF LOCAL OR STATE AGENCIES, THE COMPACTION REQUIREMENTS SHALL NOT BE LESS THAN THE MINIMUM REQUIRED BY THE APPROPRIATE RESPONSIBLE AGENCY. 8. NO FIELD CHANGES OR DEVIATIONS FROM THE DESIGN SHALL BE MADE WITHOUT PRIOR APPROVAL OF THE FPUA ENGINEER AND C[TY/COUNTY/FDOT ENGINEER. 9. THE CONTRACTOR SHALL NOTIFY FPUA ENGINEERING AND CITY/COUNTY/FDOT ENGINEERING 48 HOURS PRIOR TO COMMENCING CONSTRUCTION. 10. A PRE -CONSTRUCTION CONFERENCE BETWEEN THE ENGINEER, THE CONTRACTOR, FPUA, AND CITY/ COUNTY/FDOT ENGINEER SHALL BE MANDATORY PRIOR TO COMMENCEMENT OF CONSTRUCTION, 11 TRAFFIC CONTROL, BARRICADES, ETC., SHALL BE IN ACCORDANCE WITH THE FLORIDA DEPARTMENT OF OF TRAN2PORTATION STANDARDS AND APPROVED BY THE CITY ENGINEER. 12. MINIMUM COVER SHALL BE 36 INCHES EXCEPT AS APPROVED BY THE UTILITIES ENGINEER AND CITY/ COUNTY/FDOT ENGINEER. PIPES WITH COVER LESS THAN 30 INCHES SHALL BE CONSTRUCTED OF DUCTILE IRON OR IN PVC CASING. 13. DISTURBED AREAS SHALL BE RESTORED IN CONFORMANCE WITH THE APPLICABLE GOVERNING AGENCY REQUIREMENTS, 14 EXISTING UTILITIES AND DRAINAGE SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION AND PROTECTED BY THE CONTRACTOR. 15. WATER MAINS SHALL BE TESTED AND DISINFECTED IN ACCORDANCE WITH THE APPLICABLE FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION AND AWWA C-651 FOR DISINFECTION. I - R E V I S I 0 N S - I BY � DATE I BY DATE DRAWN . . JOE M . 10/27/17 DESIGNED . . RCL 10/20/17 C � RCL 11/03/17 1 11 - QA/QC RML 4/04/18 SURVEY IREF. DRAWING NAME 1 7 3006 1 2017-0109-GEN- NOTES. d�q 23. PRIOR TO ANY TESTING, ALL MAINS 6" IN DIA. AND LARGER SHALL HAVE A LINE SIZE SWAB PASSED THRU THE ENTIRE LENGTH OF THE LINE, NCTE: SWAB SHOULD BE PLACED IN lst. JOINT OF NEW LINE. END OF MAIN SHOULD BE "TURNED UP" AT 45% AND EXTENDED SO THAT SWABBING AND A FULL BORE FLUSH CAN BE ACCOMPLISHED. BLOW -OFF ASSY CAN THEN BE PLACED. WHERE LINES BRANCH, SWABS WILL BE PLACED IN BRANCH LINES AND SEQUENTIALLY SWABBED AND FLUSHED, 24 A MINIMUM SIX FEET AND PREFERABLY TEN FEET HORIZONTAL SEPERATION SHALL BE MAIINTAINED BETWEEN THE WATER MAIN AND ANY WASTEWATER UNESNCHES MINIMUM VERTICAL SEPARATION IF WATER MAIN IS OVER WASTEWATER AND 12 INCHES IF WATER MAIN IS UNDER SHALL BE MAINTAINED BETWEEN THE WATER MAIN AND ANY WASTWATER LINES, THE DISTANCE SHALL BE MEASURED FROM OUTSIDE OF PIPE TO OUTSIDE OF PIPE OR STRUCTURE, WHERE THIS MINIMUM SEPARATION CANNOT BE MAINTAINED, THE CROSSING SHALL BE ARRANGED 50 THAT THE WASTEWATER PIPE JOINTS AND THE WATER MAIN PIPE JOINTS ARE EQUIDISTANT FROM THE POINT OF CROSSING, AND THE WATER MAIN SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE (DIP) AT THE CROSSING, SUFFICIENT LENGHTS OF DIP MUST BE USED TO PROVIDE A MINIMUM SEPARATION OF 10 FEET BETWEEN ANY TWO JOINTS, ALL JOINTS ON THE WATER MAIN WITHIN 20 FEET OF THE CROSSING MUST BE MECHANICALLY RESTRAINED, A MINIMUM VERTICAL CLEARANCE OF 6 INCHES MUST BE MAINTAINED AT ALL CROSSINGS, 25. WHERE A WATER MAIN 19 TO BE INSTALLED BELOW A STORM DRAIN PIPE, A MINIMUM OF 6 INCHES OF VER71CAL CLEARANCE BETWEEN PIPES SHALL BE CONSTRUCTED OF DIP AT THE CROSSING, AND SHALL BE MECHANICALLY RESTRAINED WITHIN 20 FEET OF THE CROSSING, 26. CONTRACTOR SHALL COMPLY WITH FLORIDA TRENCH SAFETY ACT REQUIREMENTS, FORT PIERCE UTILITIES AUTHORITY WASTEWATER CONSTRUCTION NOTES 1. ALL CONSTRUCTION MATERIAL, INSTALLATION AND TESTING SHALL CONFORM TO THE STANDARD SPECIFICATIONS OF THE FORT PIERCE UTILITIES AUTHORITY. 2, GRAVITY SEWER MAIN SHALL BE POLYVINYL CHLORIDE SDR-35, GREEN OR WHITE IN COLOR, GRAVITY SEWER MAIN SHALL HAVE LOCATOR TAPE WITH "SEWER" MARKED ON TAPE AND SHALL CONFORM TO ASTM D-3034, 3. THE MANHOLE BASE SHALL BE SET ON A FIRM, DRY AND STABLE OR COMPACTED BASE FOUNDATION. IF NECESSARY, THE CONTRACTOR SHALL UTILIZE ROCK TO PROVIDE A FIRM AND SUITABLE MANHOLE BASE FOUNDATION, 4 WASTEWATER LINES SHALL BE BACKFILLED AND COMPACTED IN ACCORDANCE WITH FPUA DESIGN AND CONSTRUCTION STANDARDS. THE CONTRACTOR SHALL SUBMIT CERTIFIED DENSITY TESTS AS REQUIRED BY FPUA ENGINEERING AND THE CITY ENGINEERING DEPARTMENT. IN CASES WHERE PAVED AREAS FALL WITHIN THE JURISDICTION OF LOCAL OR STATE AGENCIES, THE COMPACTION REQUIRE- MENTS SHALL NOT BE LESS THEN THE MINIMUM REQUIRED BY THE APPROPRIATE RESPONSIBLE AGENCY 5 A 1% MINIMUM SLOPE SHALL BE MAINTAINED ON ALL SANITARY SERVICE LATERALS. 6. THE CONTRACTOR SHALL FURNISH RECORD DRAWING INFORMATION TO THE ENGINEER CONSISITING OF PIPE SIZES, LOCATION OF SERVICE TEE WYES, DIAMETER OF SERVICES, LOCATION OF ANY FITTINGS, FINAL RIM AND INVERT ELEVATION OF ALL MANHOLES AND ANY OTHER PERTINENT INFORMATION NECESSARY TO LOCATE ITEMS CONSTRUCTED UNDER THIS PROJECT. 7. MAINTAIN SIX FEET AND PREFERABLY 10 FEET HORIZONTAL DISTANCE BETWEEN WATER MAINS AND SEWER MAINS AS A MINIMUM. 8 WASTEWATER FORCE MAINS, WASTEWATER COLLECTION LINES, AND STORM SEWERS SHOULD CROSS UNDER WATER MAINS WHENEVER POSSIBLE. A MINIMUM VERTICAL DISTANCE OF 12 INCHES BETWEEN THE INVERT OF THE UPPER PIPE AND THE CROWN OF THE LOWER PIPE SHALL BE PROVIDED WHENEVER POSSIBLE. WHERE THIS MINIMUM SEPARATION CANNOT BE MAINTAINED, THE CROSSING SHALL BE ARRANGED SO THAT THE WASTEWATER PIPE JOINTS AND THE WATER PIPE JOINTS ARE EQUIDISTANCE FROM THE POINT OF CROSSING, AND THE WATER MAIN SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE (DIP) AT THE CROSSING. SUFFICIENT LENGTHS OF DIP MUST BE USED TO PROVIDE A MINIMUM SEPARATION OF 10 FEET BETWEEN ANY TWO JOINTS. ALL JOINTS ON THE WATER MAIN WITHIN 20 FEET OF THE CROSSING MUST BE MECHANICALLY RESTRAINED, A MINIMUM VERTICAL CLEARANCE OF 6 INCHES MUST BE MAINTAINED AT ALL CROSSINGS. 9. A PRE- CONSTRUCTION CONFERENCE BETWEEN THE ENGINEER, THE CONTRACTOR, AND FPUA/CITY COLINTY/FDOT SHALL BE MANDATORY PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 1& NO FIELD CHANGES OR DEVIATIONS FORM THE DESIGN SHALL BE MADE WITHOUT PRIOR APPROVAL FPUA/CITY/COUNTY/FDOT ENGINEER, 11. TRAFFIC CONTROL, BARRICADES, ETC, SHALL BE IN ACCORDANCE WITH THE FLORIDA DEPARTMENT OF TRANSPORTATION STANDARDS. 12. CONTRACTOR SHALL NOTIFY FORT PIERCE UTILITIES AUTHORITY 48 HOURS PRIOR TO COMMMENCING CONSTRUCTION. 13, WASTEWATER FORCE MAIN SHALL BE POLYVINYL CHLORIDE CONFORMING TO AWWA C-900, AND SHALL BE CLASS 150, DR-18, 14. WASTEWATER FORCE MAIN SHALL BE GREEN IN COLOR OR WHITE IN COLOR. WASTEWATER FORCE MAIN SHALL HAVE THHN WIRE & LOCATOR TAPE WITH "SEWER" MARKED ON TAPE. OF THE PIPE. 15, FITTINGS SHALL BE CAST OR DUCTILE IRON, CONFORMING TO AWWA C-110 AND ANSI A21.11, CLASS 250 MINIMUM, INTERIOR POLYLINED, AND SEAL COATED. 16, WASTEWATER FORCE MAIN SHALL BE MARKED BY THE USE OF CONTINUOUS 10 GAUGE THHN WIRE (GREEN IN COLOR) PERMANENTLY ATTACHED TO THE TOP OF THE FORCE MAIN WITH LOCATOR TAPE MARKED "SEWER" ON TAPE IN ACCORDANCE WITH FPUA SPECIFICATIONS. 17, MINIMUM COVER SHALL BE 36 INCHES, PIPES WITH COVER LESS THAN 30 INCHES SHALL REQUIRE PRIOR APPROVAL OF THE UTILITTES ENGINEER AND SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE. 18. EACH SERVICE LATERAL WILL BE MARKED WITH A LOCATOR BALL AS MANUFACTURED BY 3M CORPORATION, OR APPROVED EQUAL AS REQUIRED BY FPLA ENGINEER. 19. ALL MANHOLES SHALL HAVE SEWER RAIN GUARDS INSTALLED AS REQUIRED BY FPUA ENGINEER. 20. THE CONTRACTOR SHALL COMPLY WITH THE FLORIDA TRENCH SAFETY ACT REQUIREMENTS. "m p w Rm 4wft ,�� -_ .- IF- I ATLANTIC CIVIL ENGINEERING, INC. CONSULTING ENGINEERS 2552 PETERS ROAD SUITE D FORT PIERCE, FLORIDA 34945 (772) 398-1520 PHONE (772) 398-1521 FAX CERTIFICATE OF AUTHORIZATION #32020 CALL TOLL -FREE 1-800-4�2-4770 SUNSHINE STATE ONE CALL OF FLORDA, INC UNDEROROUND UTILITIES NOTIFICATION CENTER DATE! 3/23/18 JOB No 2017-0109 HORIZ SCALE: 1"=40' - - I SHEET 8 OF 8 VERT SCAI F, N 1A I RICHARD MI SA�)A�O/ P.E. #34288 VATE I* CONSTRUCTIONPLANS 1040" WmAl IDA 911—j 99A OPERTIES, PROPOS D MASONRY CONTRACTOR'S p AMA Cl�; AINE! PROJECT VICINITY VICINITY MAP I N.T.S. DESCRIPTION AUGUSTINE �LTONA BEACH IEY�IEST LOT 8, AIRPORT INDUSTRIAL PARK UNIT ONE REPLAT, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 20, PAGE 3, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. Fr. PIERCE T ART UBE So JWE 9 � I PMD BEACH FT. LAUDERDALE MIAMI ST. LUCIIE COUNTY, FLORIIDA SECT11ON 29, TOWNSMP 34 SOUTH, RANGE 40 EAST INDEX rl'O SHEETS SHEET NO. DESCRIPTION I COVER SHEET 2 SITE PLAN 3 PAVING, GRADING & DRAINAGE PLAN 4 UTILITY PLLN 5 PAVING, GRADING & DRAINAGE DETAILS 6 WATER & SEWER DETAILS 7 LIFT STATION PLAN/UTILITY DETAILS 8 GENERAL NOTES PREPARED BY ATLANTIC CIVIL ENGINEERING, INC. CONSULTING ENGINEERS 2552 PETERS ROAD * SUITE D * FORT PIERCE, FLORIDA 34945 * (772) 398-1520 PHONE * (772) 398-1521 FAX State of Fioricc Board of Professional Engineers Authorization No. 32020 N.T.S. m'- I-F;ONT _12L ��;o�s — r, to �TIES REAR OFFIC RLr,%0 ECRONE, b JuNileoia BY, M.LADYktr--�/ FLP.E.No.34288 DATE I JOB No. 2016-0034 1 SHEET I OF 8 'EXISTING FIRE HYDRANT wal 011 m m GRAPHIC SCALE 20 0 10 20 40 8 ( IN FEET ) 1 inch = 20 ft PROPOSED SITE DATA & COMPONENT ACRES SO FT. % OF SITE PROPOSED BUILDING 0.14 5,933 12.9 PROPOSED PAVING & WALKS 0.27 11,761 25.6 TOTAL IMPERVIOUS 0.41 17,694 38.6 DRY DETENTION 0.05 2,178 4.7 OPEN SPACE 0.59 26,061 56.7 EXISTING 8" WATER MAIN - \ W_ EXISTING 4" FORCE MAIN _FM- R/W�_L­INE - SITE z �ST LU CIE Co. AIRPORT-)= ST LUCIE BLVD L0 L FM W W ASPHALT _T m FM PROPOSED 1" WATER SERVICE PROPOSED STOP BAR & STOP SIGN -, luf IN INDUSTRIAL 27TH STREET (80' R/W) PROPOSED SIGN /-IN WALL NOO-47'10"W PROPOSED 366.00' 6' CIL FENCE - (OVERALL) 27. PROPOSED PROPOSED DETENTION AREA DETEUTION -AREA V) 7 </ _x PR(XP__0SE_D 6 F-17- - - Em \-PROPOSED 59.33' L_J Z CBS WALL PROPOSED 2" FM PROPOSED 26 <11(TYP) GAT PUMP STATION Cn Z� ayj / �r. <i 16" PINE* z I - /r). ��/ . - ws- . zj </ PROPOSED </ 5933 SF 10, 20'---1 Lu a- 0 1-STORY 0- 141 D_ 2: 4�M < 0 6 0 BUILDING 0 <j zj 4qV 19" pl�' 1 26' Z PROPOSED __� Z, I (TYP) 5' CONC WALK 4 LOCATION MAP 11 LOADING ZONE NOT TO SCALE \ \ 'A� I \ \< \�, ��. 1 41 11 </ -- PROPOSED CONC..)�'Z�/_� 23" PINE # DRIVE AND<PARKING TOTAL SITE AREA 1.05 45,933 100.0 /1 <i ZA <1 ZA 16" PlNE* -113.5< GENERAL NOTES 10.0' (AUSTRALIAN) Z 1 < 59.33' 1. PROJECT NAME: DOYLE PROPERTIES, LLC INDUSTRIAL 27TH STREET 3: 4 2. LOCATION: SECTION 29, TOWNSHIP 34 SOUTH, RANGE 40 EAST 0-0 Po 0-) Z� /J</ zj Z� �-PROPOSED /k</ 4L� FORT PIERCE, FLORIDA p D&VPSTER Z_ 1 41 3. OWNER: DOYLE PROPERTIES, LLC 0) 00 Cf) </ </ ENCLOSURE 00 I <1 LOT 8 <j P.O. BOX 12339 zk </ 4� FORT PIERCE, FLORIDA 34979 Z 4� <1 4� LOT 9 <1 ZI 4. APPLICANT DOYLE PROPERTIES, LLC P.O. BOX 12339 PROPOSED C FORT PIERCE, FLORIDA 34979 (EOUOMENT/VEHICLI�/. MAVIAL_, STORAGE-) 5 ENGINEER: ATLANTIC CIVIL ENGINEERING, INC. PROPOSED - I _: 1 11 . .1 50'N. 2552 PETERS ROAD SUITE D IRRIGATION FORT PIERCE, FLORIDA 34945 WELL PHONE: (772) 398-1520 PROPOSED�' 8' OPAQUE 6. SURVEYOR: LAVENTURE & ASSOCIATES, INC. FENCE 2552 PETERS ROAD SUITE D FORT PIERCE, FLORIDA 349A,.r PHONE: (772) 398-6430 7. DESCRIPTION: LOT 8, AIRPORT INDUSTRIAL PARK UNIT ONE REPLAT, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 20, PAGE 3, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. 10' BLDG SETBACK OWNER: TREASURE COAST FOOD BANK, INC. EXISTING ZONING: IL 8. PARCEL ID NO: 1429-502-0008-0007 LAND USE:IND 9. TYPE OF PROJECT: MASONRY CONSTRUCTION OFFICE 10. PROJECT SIZE: 45,933 SQ FT. (1.06 ACRES) GROSS AREA 11. BUILDING SIZE: 5,933 SQ FT. (0.14 ACRES) LOT 10 12. FUTURE LAND USE: IND (INDUSTRIAL) 13. EXISTING ZONING: IL (LIGHT INDUSTRIAL/ST. LUCIE COUNTY) 14. FLOOD ZONE: ZONE X 15. PARKING: REQUIRED 8 SPACES PROVIDED 8 SPACES 16. DEVELOPMENT BEGIN CONSTRUCTION: APRIL, 2018 SCHEDULE: CONSTRUCTION TO BE COMPLETED: 180 DAYS 17. UTILITY SERVICE: WATER SERVICE FORT PIERCE UTILITIES AUTHORITY SEWER SERVICE FORT PIERCE UTILITIES AUTHORITY 18. SITE DRAINAGE: THE STORMWATER MANAGEMENT SYSTEMS WILL CONSIST OF DETENTION AREAS WITH AN OUTFALL TO THE ROADSIDE SWALE AND WILL BE DESIGNED PER ST. LUCIE COUNTY AND SOUTH FLORIDA WATER MANAGEMENT DISTRICT CRITERIA. -1 1 X-A A- 0 PROPOSED SILT FENCE AND LIMITS OF CLEARING S -S S 50' NATIVE VEGETATION BUFFER 16" PINE (AUSTRALIAN) 20' BLDG SETBACK 183.00' y ��PROPOSED 6' CIL FENCE LOT 11 OWNER: JOHN LANGEL, ET AL EXISTING ZONING: IL LAND USE:IND PARKING DATA USE ITE CODE RATE(PER 1,000 SF) SF SPACES OFFICE 701 2.84 1780 (5.0) 5 SPACES WAREHOUSING 150 0.50 4153 (2.0) 2 SPACES SITE PLAN DOYLE PROPERTIES, LLC Lu 0-0 0 P m Co I Ap _X �-x---- 25' BLDG SETBACK '10' BLDG SETBACK 20' BLDG SETBACK EXISTING 8" WATER MAIN DRIVEWAY WITHIN R/W TO ��BECONSTRUCTED WITH PHASE 1 183.00' LOT 7 I _j SOO*47'1 0"E 366.00' LOT 12 (OVERALL) OWNER: WARREN HEIM CORP. EXISTING ZONING: IL LAND USE: IND TRAFFIC STATEMENT ITE LAND USE GENERAL LIGHT INDUSTRIAL (X = 40 EMPLOYEES AVG. 7 SPACES (8 SPACES PROVIDED) E V I S 1 0 N S - BY DATE LREVISED DATA Ti�BUE; OMITTED SIDEWALK JOE M 5/4 418 ��DD 8' FENCE JOE. M. 5/11/18 .. . . ...... . . .. .............................. ................ ....... ............. . . I ......... . ......... I ....... .. 11 11.1 ... I ....... ............ I � ......... .. ..... DAILY TRIP GENERATION T = 2.95 (X) + 30.57 = 149 TRIPS AM PEAK TRIP GENERATION T = 0.27 (X) + 70.47 = 82 TRIPS (68/IN AND 14/OUT) PM PEAK TRIP GENERATION T = 0.29 (X) + 58.03 = 70 TRIPS (15/IN AND 55/OUT) BY DATE DRAWN JOE M 10/24/17 DESIGNED RCL 11/10/17 CHECKED RCL 11/13/17 OA/QC RML 11/14/17 SURVEY REF. DRAWING NAME 17.3006 1 2017-0109 SITE-PL41 ATLANTIC CIVIL ENGINEERING, INC. CONSULTING ENGINEERS 2552 PETERS ROAD SUITE D FORT PIERCE, FLORIDA 34945 (772) 398-1520 PHONE (772) 398-1521 FAX CER11FICATE OF AUTHORIZATION #32020 182' __"Y� EXISTIN0 FIRE HYDRANT T- W "o C� u C 4 R/W LINE -PROPOSED 6' CL FENCE 10' BLDG LOT 6 SETBACK C OWNER: TONAKI, LLC EXISTING ZONING: IL LAND USE:IND LOT 13 DATE: 3/23/18 111111 JOB No. 2017-0109 HORIZ SCALE: I"=20' SHEET 2 OF 8 VERT SCALE: N/A 11 USF Frame and Grate as Indicated. For Traffic Areas use USF 4155-6209. For Non -Traffic Areas use USF 8"x8" Conc. Collor 6210. - - - - - - - - - w/ NO. 5 Bar Cont. 2 1/2"x2 1/2"x1/4" Angle 'N/ 3/16"x1"x6" Anchor Welded 0 6" D.C. Grout If min 18" Precast Pavement & Me 3'- 1 Backfill XTbkk. a Generate slg,3�& 5 Reffiferoa WF -WJ.4xW1.4 4 PIPE SIZE TYPE AND TOP VIEW -SINGLE PIPE INVERT AS INDICATED can R.f ' ' , ON PLAN SHEETS - r5i'm e 41g, 12; I [ Am anw; � 0,11WII V Plpa ra 5J Sne, 99; 4 S '4? I 1 1 1 4 Sid. D10ah Gradai ............. 2' Less r� PraVff*d,, 5-W ad unless r,, E ear *SI.P, Andf S.110'. �d I Large, f 5, f pip, To Be faladded, Under Unit Price Per Mitered W 50flan) 1.2 MIW, To t PIP. Far PfPO- 18- And Seedier. 1�� 1 1.11 IdFor PIpea 24" And Larger. 15" R.C.P. MITERED END SECTION CONSTRUCT MITERS PER FDOT INDEX 273 PER LATEST FOOT DESIGN STANDARDS PAVEMENT SECTION 1 1/2"R BASE 'A A SUBGRADE #4 BARS CONT. NOTE: ALL CURBS TO BE SAWCUT 0 5' INTERVALS. h\ 39 (DCONSTRUCT W/ 3,000 PSI (MIN.) 12 HEADER CURB CONCRETE AT 28 DAYS TOP OF BERM EL.= 18.15 MIN. 3:1 �3� EXISTING GRADEU� MAX. MAX. MINIMUM PERIMETER BERM 12.0' el TOP EL.== 17.0-1 TOP OF BERM EL.= 18,15 MIN. 3:1 MAX. 3 �3 1 '1 M M M�X. AX. AX B OTTOM OTTOM EL.= VARIES 16.0-17.0 TYPICAL SWALE SECTION @ PROPERTY LINE TOP EL.= 17.0-1 TOP EL.= 18.00 EL.= 17.0-18.15 IES 16.0-17.0 TYPICAL SWALE SECTION (SEE PLAN�- 3:1"`�'_BOTTOM E�L.=1600��3:1 MAX. MAX. DRY DETENTION SECTION TOP EL.= 18.00 8" Concrete w/ No. NOTES: 4 Bars At 12" O,C. Construct Type "C" Inlet per FDOT Index #232. TYPICAL TYPE "C" INLET I�LAIN #4 DOWEL FOR ANCHORING- T 2 REQUIRED #4 BAR 5-8" LONG 7 2� :5 - 4'-0" V-0- 6'-0" FRONT ELEVATION SECTION PRECAST CONCRETE WHEEL STOP ,pe Curb NOTES: 1. Use 3,000 P.S.I. concrete at 28 days for construction. 2. Subgrade to extend an additional 6" beyond Type "D" Curb. 3. Type "D" Curb to be constructed In accordance with FDOT Index #300. TYPE "D" CURB VARIES Provide 1/8" to 1/4" contraction /joints at 5' centers (max). 'Compact Subgrade to 98% of the Maximum Density as Determined by AASHTO T-99 NOTES: 1. Use 3,000 P.S.I. Concrete At 28 Days for sidewalk construction. 4 THICK SIDEWALK DETAIL CONSTRUCT SIDEWALKS PER FDOT INDEX 310 PER LATEST FDOT DESIGN STANDARDS Backfill For Storm Sewer To Be Uniformly Deposited nd Compacted In Accordance With FDOT Standard Specifications Section 125-8.3 Latest Edition 12" Pipe O.D. 12" Design Grade ranIde I h f lot Slo Side Slope To Be No Flatter Th Necessary To 1 11 To Inestall Pipe \�Shape To Receive Bell For R.C.P. 1/2 Pipe Diameter For C.A.P. STORM PIPE BEDDING DETAIL 20' PARKING 26' INAVtL FILTER FABRIC TO EXTEND 8" MIN. FROM GRATE SIDES PREDOMINATE FLOW, METAL INLET GRATE FILTER FABRIC TO CONTINUE UNDER ENTIRE 4 GRATE. 0 4 PICTORIAL VIEW GENERAL NOTES 1. THIS INLET IS DESIGNED WITH FILTER FABRIC PROTRUDING 8" FROM SIDES FOR GRIPPING WHEN SEDIMENT NEEDS TO CLEARED AFTER FINAL CONSTRUCTION. 2. FILTER FABRIC TO 13E INSTALLED AND TRIMMED BEFORE GRATE IS INSET. FILTER FABRIC DETAIL EDGE OF PAVEMENT 24" STOP BAR PAINT 4't6 30' MAXIMUM �1�1 2' 24"x24" TYPICAL - STOP UNLESS OTHERWISE I(S NOTED Wtolf - TYPICAL STOP SIGN LOCATION DETAIL �1'_V' DIA. TYPICAL PAVEMENT DETAIL (D CONSTRUCT 6" THICK CONCRETE (3,000 PSI MIN.) SYMBOL SHALL BE PAINTED W/ FIBREMESH 0 1/5 LB PER CY NTH WHITE PAINT AND TO (2) 12" STAE31LIZED SUBGRADE (COMPACTED THE DIMENSIONS SHOWN MIN. 98% OF AASHTO T-180) (LBR 40 MIN.) 12\ HANDICAP SYMBOL SECTION A -A, TYPICAL PAVEMENT SECTION PAINT DETAIL � PAVING, GRADING9 AND DRAINAGE DETAILS DOYLE PROPERTIES A ASTR PING & SIGNAGE PER FDOT INDEX 17346 AND 17355 PER LATEST FDOT DESIGN STANDARDS R E V I S 1 0 IN S BY DATE &REVISE SINALE/BERM ELEVATIONS ...... ...... . JOE M., 5/4/18 REVISE 'PAVEMENT SECTION TO' CONCRETE� ADD FD'OT INDICES JOE M 5/17/113 1 ......... .... ......... ........ . ....... .. . I .. A.R.E.\.A.SE..F.D.O.T..I.N.DiC.E.S.. . ...... ......... ......... ... ... ..... I...... ......... 1. ..... JOE.M. VW18 BY DATE DRAWN JOE M 10/27/17 DESIGNED ... RCL 10/20/17 ......... CHECKED RCIL ...... 11/03/17 � 1. ......... QA/QC RML 11/08/17 1 SURYI�� REF. DRAWNP N�.ME 1 08.1067 12016-0034-P66 HANDICAP SIGN BLUE FTP 25 NOTES: 1. TOP PORTION OF FTP 25 & 26 SHALL HAVE A REFLECTIVE BLUE BACKGROUND WITH WHITE REFLECTIVE SYMBOL AND BORDER. 011% BLUE 2. BOTTOM PORTION SHALL HAVE A REFLECTIVE WHITE BACKGROUND WITH BLACK OPAQUE LEGEND AND BORDER. 3. FTP 25 & 26 MAY BE FABRICATED ON ONE PANEL OR TWO. 4. FTP 25 IS FOR USE IN AREAS WHERE Bl. UZI BL JE SPACE IS LIMITED. HANDICAP SPACE DETAIL STRIPING & SIGNAGE PER FDOT INDEX 17346 AND 17355 PER LATEST FDOT DESIGN STANDARDS 12" MIN6 FILTER FABRIC TO EXTEND On 'Ilk' rROM GRATE SIDES z LO PARKING BY DISABLED PERMIT ONLY r$250 FINE, ,o 1 1 F.S, 318.14 1 1 2 IN 0 ,a 4 *.U4 C14 L .4 "12 to HANDICAP PARKING SIGN 4" MIR PLAN VIE-W e WEIR WALL T.O.W. EL. - 111.15' INUT TOP ELEVATION 19.00 TOP WEIR ELEVATION 18.15 12"HIGH 3" VADE MIR KIR 11EV. OPENING -ELEVATION 17.50. 1 DRY DETENTION !GTTOM ELEV. 18.0 DRY DETENTION BOTTOM ELEV. - 16.0 15"ROP 3" DA. 15"RCP ILEEIM PIP, INVERT 21.11. Ir 20 STRUCTI.IRE BOTTOIA -FTP-26 WHITE ON BLUE BLACK ON WHITE - LETTERS W11 1/2 -BLACK ON WHITE FTP-55 ALPOST CONST. 3* DIA-r BLEEDER 0 EL-15.4 SECTION A -A SECTION B-B CONTROL STRUCTURE DETAIL INC. ATLANTIC CIVIL ENGINEERING, CONSULTING ENGINEERS 2552 PETERS ROAD SUITE D FORT PIERCE, FLORIDA 34945 (772) 398-1520 PHONE (772) 398-1521 FAX CERTIFICATE OF AUTHORIZATION #32020 DATE: 11/08/17 HORIZ SCALE: I"=40' VERT SCALE: N/A M. MODIF ED TYPE 11C. INILET DETENTION EL - 15,0 JOB No.2017-0109 SHEET OF8 5 AFFIXED BY TAPE TUBING S s0SRNG WATER MAIN WINE RINI ROWC npE mum wx By OOKIIIIIACTOR FINISHED GRADE f7glyrO Ig IN EKlSI?NG SEE NOTT P.UA WATER MAIN I' OR 2' P017SIVICNE ruff CC LOCKABLE METER VALVE CORPORATION STOP (NOTE 5) (OURS STOP FORD PART I S4I-XXXX-G,' THNN WINE WITH ONE SHOT LOCK (STERLING SECURITY SYSTEM JR-00 "7=�� STAINLESS STEEL DOUBLE STRAP SERVICE SADDLE NO WITH I.P. THREAD 1. OWE 10 GAUGE THHN WRE $HALL BE ATTACHED TO THE SERVICE LANE I WHERE SERVICES UNDER PAVEMENT ARE REQUIRED, THE POLYETHYLENE TURING SHALL BE INSTALLED WITHIN SCHEDULE 40 PVC CASING PIPE J. I - & 314- METER SIZES "LL REQUIRE A LOCK49LE METER VALVE (CURB STOP) 4. MINIMUM COVER IN UNPAVED AREAS SHALL BE 30", IN PAVED AREAS OR PLANNED ROADWAYS OR SWALES MIN. COVER SNAU BE 361, 5. MR 2' COMMERCIAL SERVICE INSTALLAIT". FPUA WILL INSTALL ABOVE GROUND METER PER DEIAIL W-8. TYPJCAL SINGLE WATER SERVICE CDKN0770 (N.I.S.) WATER SERVICE DETAIL SEE M07F P HE p2u V VCP PlIwff PW LINCR Eff PfPlUNE PROPliz vim ffl-w IN IA v IT 0, n wmvr IMr4L 4' OR 6' WASTEWATER SERVICE - 6100 WINC emu mHuff (TYPICAL) OR IMSERIA-TEE SOME OR 'VS ARE NOT TV BE USE) DURING NEW CONSTRUC77011- .ES ARE ONLY APPROVED FOR INSTALLATION ON 24' AND WER MAINS. )DIE SHALL BE USED AS A TEMPLATE FOR DETERMINING HOLE ,OCATION. RE GRADE ADHESIVE SHAU BE USED TO SEAL ROA440 GASKET SED LINER TO VCP WITH HY"UUC CEMENT ) FOLD STRAP PACK AQAWST IISELF PLACING FREE END TRAP AND PIPE ON SMALL PIPE, IT 94Y BE NECESSARY TO TWICE (N.T.S.) WASTEWATER SERVICE DETAIL 2 112- AVC, WN. W OW W/ 314- OVI'LEF OR AIIIIIIIIIIII011W EM 314-P.V.r. WA 40 OR COPPER FNE HYDRANT a4LLL VALW PROPOSIM "RES01AED ..... OMDE 0 BACTERIOL a nRE H 25r 4* 7130VRARY MAWIM (AI EL FORD CURB nNISHED GWE A I' POLn7mnvK SERV70E LNE CORPORATION 37up FORD F7 10 OW APPAOM X&ML MUSS SnR WME snmp $9WE S41CIVILE WIN 4P.T. a4CTFRl0LQaaK 94UPlING POINT 0 WATER MAIN (MT.S.) ARM MMW MWW I' RE ENE AW CAP WITH SIRASS PLUS AT OOMMMN $MR. W-6 s4crsmoa" &WpuNG PI f - Am WA BIT ft. AMM 11MRIES; AUMVTP RAW IL Mfg BACTERIOLOGICAL SAMPLING POINT NOTE: PLEASE REFER TO FORT PIERCE UTILTIES STANDARD SEPARATION STATEMENT FOR WATER / SEWER CONFLICTS, UTILITY CROSSING OETAI N.TS, UT/L/TY CROSSING DETAIL 1 M-5 PC I ft UTILITY CROSSING DETAIL FINISH GRADE SEE NOTE NO. 5 12" INITIAL BACKFILL TMBEOMEN7 SPRING MATERIAL LINE or PIPE X HAUNCHING BE M �DIRE6 6- IN. IF UIRED) FOUNDATION X (MAY NOT BE REQUIRED) BACKFILLING REQUIREMEN N.T.S. NOTES: 1) IN CERTAIN SOIL CONDITIONS A FOUNDATION MAY BE REQUIRED. 2) BEDDING 15 REQUIRED PRIMARILY TO BRING THE TRENCH BOTTOM UP TO GRADE. BEDDING MATERIALS SHALL PROVIDE A UNIFORM AND ADEQUATE LONGITUDINAL SUPPORT UNDER THE PIPE. 3) HAUNCHING MATERIAL SHALL BE HAND PLACED TO THE SPRINGLINE OF THE PIPE. MATERIAL SHALL BE CONSOLIDATED UNDER THE PIIPE AND HAND TAMPED TO PROVIDE ADEQUATE SIDE SUPPORT. 4) INITIAL BACKFILL MATERIAL SHALL 13L HAND PLACED TO 12" ABOVE THE TOP OF PIPE. THE SOIL SHALL BE COMPACTED TO 100% MAX, DENSITY,(AASHTO T-99) 5) BACKFILL SHALL BE COMPACTED TO 100% OF MAX. DENSITY AS PER AASHTO T-99, TO A POINT 30" BELOW PROPOSED PROFILE GRADE OR EXISTING GRAIDE, THE FINAL 30" OF PACKTILL SHALL BE COMPACTED TO 987 OF MAX. DENSITY AS PER AASHTO T= 180: 6) DENSITY TEST SHALL BE PERFORMED AT AREAS DETERMINED BY THE UTILITIES ENGINEER OR PERMIT AGENCY HAVING JURISDICTION, AT THE CONTRACTORS EXPENSE, 7) CONTRACTOR TO COMPLY WITH ALL FEDERAL, STATE AND LOCAL TRENCH SAFETY RIZCULATIONS� FACKFILLING REGUIREMENTS W�2 WS-09 NOTES DATE., 1111 RE 10 Y, I APPD' Nsle'VED. compu;km tru! , Jim MISC DETAILS 200802.10KI PAWN BY. S Jim INTS, DATE. SHEET ET 2010 :E aTANDARD SEPARATION STATEMENT FO WATER / SEWER CONFLICT 1. SANITARY SEWER. FORCE MAINS, AND STORM SEWERS SHOULD CROSS UNDER WATER MAINS WHENEVER POSSIBLE. SANITARY SEWERS. FORCE MAINS AND STORM SEWERS CROSSING UNDER WATER MAINS SHALL BE LAID TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 6 INCHES, PREFERABLY 12 INCHES BETWEEN THE INVERT OF THE UPPER PIPE AND THE CROWN OF THE LOWER PIPE WHEN ABOVE, AND AT LEAST 12 INCHES OF SEPARATION WHEN THE WATER MAIN IS BELOW, WHERE SANITARY SEWER, FORCE MAINS, STORM SEWERS MUST CROSS A WATER MAIN WITH LESS THAN 6 INCHES VERTICAL SEPARATION, BOTH THE SEWER AND WATER MAIN SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE (DIP) CENTERED ON THE CROSSING. (DIP IS NOT REQUIRED FOR STORM SEWERS,) SUFFICIENT LENGTHS OF DIP MUST BE USED TO PROVIDE A MINIMUM SEPARATION OF 10 PEET BETWEEN TWO JOINTS, ALL JOINTS ON THE WATER MAIN WITHIN 20 FEET OF THE CROSSING MUST BE MECHANICALLY RESTRAINED. &L CROSSINGS SHALL BE ARRANGED 60 THAT THE SEWER PIPE JOINT% AND WATER MAIN PIPE JOINTS ARE FOLJIHI%TA14T FROM THE POINT OF CRO59ING tPIPES CENTERED ON THE GROSSING): AT SUCH CROSSINGS PIPES WHERE A NEW PIPE CONFLICTS WITH AN EXISTING PIPE WITH LESS THAN 6 INCHES VERTICAL CLEARANCE, THE NEW PIPE SHALL BE CONSTRUCTED OF DIP (EXCEPT STORM SEWER%) AND NEW PIPES SHALL BE ARRANGED TO MEET THE CROSSING REQUIREMENTS ABOVE: 2: A MINIMUM �-FOOT HORIZONTAL SEPARATION SHALL BE MAINTAINED BETWEEN Aw TYPE or STORM §EWER AND WATER MAIN IN PARALLEL INSTALLATIONS WHENEVER POSSIBLE, A MINIMUM 3=FOOT. AND PREFERABLE 10-FOOT HORIZONTAL SEPARATION SHALL BE MAINTAINED BETWEEN VACUUM TYPE SANITARY SEWER AND WATER MAIN IN PARALLEL INSTALLATIONS WHENEVER F0.591BLE, A MINIMUM 10-FOOT HORIZONTAL SEPARATION SHALL BE MAINTAINED BETWEEN "ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM" AND WATER MAIN IN PARALLEL INSTALLATIONS WHENEVER POSSIBLE, A MINIMUM 6-FOOT, AND PREFERABLE JO=FOQT HORIZONTAL SEPARATION SHALL BE MAINTAINED BETWEEN GRAVITY OR PRESSURE TYPE SANITARY 5EWER, WASTEWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER AND WATER MAIN IN PARALLEL INSTALL4TION5 WHENEVER POSSIBLE, THE MINIMUM HORIZONTAL SEPARATION DISTANCE BETWEEN WATER MAINS AND ORAVITY=TYPE SANITARY SEWERS SHALL BE REDUCED TO 3 FOOT WHERE THE 9070M OF THE WATER MAIN IS LAID AT LEAST $19 INCHES ABOVE THE TOP Of THE SEWER IN CASES WHERE 17 IS NOT POSSIBLE TO MAINTAIN A 10-FOOT HORIZONTAL SEPARATION. THE WATER MAIN MUST BE LAID IN A SEPARATE TRENCH OR ON A UNDISTURBED EARTH SHELF LOCATED ON ONE SIDE OF THE SEWER OR FORCE MAIN AT SUCH AN ELEVATION THAT THE BOTTOM OF THE WATER MAIN Is AT LEAST 6 INCHES ABOVE THE TOP OFTHE SEWER. WHERE 17 IS NOT POSSIBLE TO MAINTAIN A VERTICAL DISTANCE OF 6 INCHES IN PARALLEL INSTALLATIONS, THE WATER MAIN SHALL BE CONSTRUCTED OF DIP AND THE SEWER OR THE FORCE MAIN SHALL BE CONSTRUCTED OF DIP (EXCEPT STORM SEWER) WITH A MINIMUM VERTICAL DISTANCE OF 6 INCHES, THE WATER MAIN SHOULD ALWAYS BE ABOVE THE SEWER. JOINTS ON THE WATER MAIN SHALL BE LOCATED AS FAR APART AS POSSIBLE FROM JOINTS ON THE SEWER OR FORCE MAIN (STAGGERED JOINTS). 3. ALL DIP SHALL BE PRESSURE CLASS 250 MIN.. ADEQUATE PROTECTIVE MEASURES AGAINST CORROSION SHALL BE USED AS DETERMINED BY THE DESIGN ENGINEER. STANDARD SEPARATION STATEMENT LIMIT OF UTILITIES AUTHORITY INSTALLATION PLAN TEE FOR TESTING NIPPLE WATER METER APPROVED 6ACKFLOW ASSEMBLY 6" NIPPLE 6, NIPPLE 90' ELBOW--,,., 90' ELBOW 2" LOCKABLE 2" CORPORATION CORPORATION 2" LOCKING 29 TEST PORT METER FLANGE .1� CURB STOP TEST PORT FINISHED GRADE PROFIL 2" COPLER SERVICE PIPE NOTES: 1. LANDSCAPING REQUIRED PER CITY OF FORT PIERCE OR ST. LUCIE COUNTY ORDINANCE. NO PLANTS OR TREES WITHIN 18" AROUND METER OR BACKFLOW. NO SOLDER JOINTS, 2. ASSEMBLY TO BE 29" FROM FINISH GRADE TO CENTERLINE OF THE FLANGED 90' BENQ WATER MEEU/EACKE�QW PREVENMR ASSEOL DOMESTIC SOVICC (COMMERCIAj (N,T,§:) WATER METERIBACKFLOW PREVENTER ASSEMBLY-OOMESTIC SERVICE5 W�a (METER SIZE 2" OR LESS) ZIP= "A c0RfivfP?-I% FT liffy ff 4DA' BACKFILLING REQUIREMENTS WATER METER/BACKFLOW PREVENTER ASSEMBLY DOMESTIC SERVICE (COMMERCIAL) WATER AND SEWER DETAILS R E V I S 1 0 N S BY DATE BY DATE . ..... DRAWN , DESIG I NED CHECKED OA/QC JCE_M I RCL RCL RML 10�27/17 10�20/17 11/03/17 4/04/18 DOYLE PROPERTIES, LLC SURVEY REF. 17,3006 IDRAWING NAMI 26i�-oo�4-pGi ATLANTIC CIVIL ENGINEERING, INC. CONSULTING ENGINEERS 2552 PETERS ROAD SUITE D FORT PIERCE, FLORIDA 34945 (772) 398-1520 PHONE (772) 398-1521 FAX CERTIFICATE OF AUTHORIZATION #32020 DATE 3/23/18 HORIZ SCALE: 1"-40' VERT SCALE; N/A m� JOB No,2017-0109 SHEET 6 OF 8 11 — NEMA 3R TYPE 304SS DUPLEX ELECTRICAL CONTROL PANEL TO INCLUDE EMERGENCY GENERATOR RECEPTACLE, LIGHTNING ARRESTOR, SURGE ARRESTOR, MAIN BREAKER, EMERGENCY BREAKER, PUMP BREAKERS, MOTOR STARTERS WITH THERMAL OVERLOAD PROTECTION, HIGH WATER ALARM LIGHT WITH HORN, SILENCE AND TEST, HOA SWITCHES, RUN LIGHTS, NON—RESETTABLE ELAPSED TIME METERS, AND DUPLEX ALTERNATIING CONTROL SEQUENCE AS A MINIMUM, BOTTOM OF CONTROL PANEL TO BE MOUNTED AT/ABOVE 100 YEAR FLOOD ELEVATION PANEL TO MANUFACTURED AND LABELED IN ACCORDANCE WITH UL STANDARD FOR SAFETY 508A EYS CONDUIT SEAL (TYP. OF 3) 2" CONDUIT (TYP. OF 3) 2" SCH80 PVC — VENT ASSEMBLY W/SS SCREEN TOP "A" GRADE "B" 2" ADAPT —A —FLEX CONDUIT FITTING (TYPICAL OF THREE) "J" INLET FITTING FIELD INSTALL BY OTHERS INLET INVERT "cl, no G PUMP ON 11 ALUMINUM BASIN COVER W/FLOODTIGHT 240 X 36� HINGED ACCESS DOOR AS MANUFACTURED BY USF FABRICATION 48" DIAMETER FIBERGLASS REINFORCED WET WELL 304SS LIFTING CHAIN LEGEND FT NGVD A TOP ELEVATION 19.50 8 GRADE ELEVATION 19.00 C INLET INVERT ELEVATION 1 16.00 C INLET INVERT ELEVATION 2 13.00 D ALARM FLOAT ELEVATION 13.00 E LAG FLOTT ELEVATION 12.50 FILEAD FLOAT ELEVATION 12,00 GIOFF FLOAT ELEVATION '110 ION � 50 J I INLET PIPE SIZE 6' ALUMINUM VALVE VAULT COVER W/FLOODTIGHT 24" X 36" HINGED ACCESS DOOR AS MANUFACTURED BY USF FABRICATION 316SS TOP RAIL SUPPORT (BOLTS TO NUT RAIL) 2" QUICK DISCONNEC W/DUST CA 2" RESILI NT SEAT G Tj VALVE ---24' RESILIIEFT SEAT GATI VALVE 2" CAST IRON BALL CHECK VALVE 1" SCH40 TYPE 304$S GUIDE PIPE 2" SCH80 PVC DISCHARGE PIPE MYERS PUMP MODEL WGL20-23 SUBMERSIBLE GRINDER PUMP RATED 2HP, 23OV, 3—PHASE, 60HZ LEAD PUMP ON "F" DUTY: 28 GPM @ 73 FT TDH BE 01 " Bol BE I III HORN 11 z HORN 0 ('_� I I ETMI ETMa ]SILENCE SI1_110E PLI P1.2 LT (D (D 01.1.2 R3 swi swe R4 a a OLL3 R15 OSFI OSF2 OLL4 Q OR c* c* ED REC TEST MODE ujj�� BAUPANEL • LIGHTNING ARRESTOR MOUNTED ON BACKPANEL BEHIND BREAKER FRAME • SURGE ARRESTOR MOUNTED ON BACKPANEL BEHIND BREAKER FRAME BILL OF MATERIALS BM/BE MAIN/EMERG BREAKERS SQUARE D QIJU330 BI/B2 PUMP BREAKERS SQUARE D QQU320 BC CONTR12L BREAKER SQUARE D QUU115 BR RECEPTACLE BREAKER SQUARE D QOU115 RED DUPLEX RECEPTACLE PASS & SEYMOUR 1591-1 GR GENERATOR RECEPTACLE PYLE NATIONAL JRE4100PR LA LIGHTNING ARRESTOR DELTA M0603 SA SURGE ARRESTOR DELTA CA603 PM PHASE MONITOR DIVERSIFIED S1_A230ASA Sl/S2 PUMP STARTERS TELEMECARIQUE LrlDI810 30" X 40" FIBERGLASS DL THERMAL OVERLOAD RELAY TELEMECANIQUE LR2DI314 AL ALARM LIGHT INGRAM LRX-40 REINFORCED VALVE VAULT HORN ALARM HORN EDWARDS 870P-N5 SIL SILENCE CONTROL CONCEPTS PR4 TEST ALARM TEST CARLING 6FA54-73 RI DPDT RELAY OMRON MK2P-SI20VAC ALT ALTERNATOR DIVERSIFIED ARA120ABA MODE ALTERNATOR MODE SWITCH CARLING 25E54-73 SW1/2 HAND -OFF -AUTO SWITCH CONTROL CONCEPTS SS' ETM1/2 ELAPSED TIME METER GRASSILIN FWZ�-72 PLI/2 PILOT LIGHT CONTROL CONCEPTS FVLU12OGNT P1_4-9 PUSH -TO -TEST PILOT LIGHT CONTROL CONCEPTS FVPTT120-IPBCRD 31 OSFI/2 OIL SEAL FAIL LIGHTS LITTELFUSE 970-67OA-92WRN XFMR 120X24 TRANSFORMER MICRON BO50UP7JK FU FUSE BUSSMAN FNM-2 361, RR-5 DPDT RELAY OMRON LY2-24VAC ENC PANEL ENCLOSURE RONNEX 3RSS/242410 WITH 3 P OINT DOOR LATCH SCHARGE "VFI GRINDER SYSTEM CONTROL PANEL PER ENGINEER OF RECORD ----MYERS SRA125 LIFT —OUT PUMPS OFF "G" IL ASSEMBLY L SERVICE METER 4 NEMA 4X SQUARE-D MODEL H321DS SERVICE RATED FUSED DISCONNECT BOTTOM "Id" 3/4" HOSE BIBB W/RPZ BACKFLOW DEVICE 12' STAINLESS -STEEL STRAPS THERM-O-WELD 4 1c,4 FEEDERS CONDUIT--/. CONDUIT A 1 # 6 IN 3/4 UV SCH. 80 P�V.C. GRINDER PUMP STATION DETAILS 4 2" SCH80 PVC UNION (TYPICAL OF THREE) 2" CAST IRON BALL CHECK VALVE (TYPICAL OF TWO) 2" BRONZE RESILIENT SEAT GATE VALVE (TYPICAL OF THREE) 2" SCH80 PVC PIPE TYPICAL THROUGHOUT 2" SCH80 PVC ELBOW (TYPICAL OF THREE) 2" SCH80 PVC CROSS (TYPICAL OF ONE) FINISH GRADE TO ELECTRIC TRANSFORMER __r\�3/4" x 8' COPPER GROUND ROD REAR VIE IGHT VISIBLE FROM ALL DIRECTIONS NEMA 3X - 24" x 24" x 8" STAINLESS STEEL CONTROL PANEL c RIGID GALVANIZED CONDUIT �CONDUIT SEAL OFF TO BE PLACED WITHIN 18" OF PROVIDE 10' x 2.�' x 6"�/ z ELECTRICAL ENCLOSURE. m (3 - 1 1/2" REQUIRED) CONCRETE PEDESTAL WITH #4 BAR 12" O.C. E.W. —NEMA 4X-6" x 6" x 24"STAINLESS STEEL WEATHERPROOF JUNCTION BOX WITH TERMINAL STRIP TO ELECTRIC TRANSFORMER 5 IN T WET WELL -FINISH GRADE =��(SEE NOTE 1) r90 SWEEP PR OVIDE THREE SEPARATE CONDUITS FOR MOTOR CABLES AND LIQUID LEVEL REGULATOR CABLES. CONDUIT $HALL BE SIDE VIE SCH 80 PVC 1-1/2". NOTES, 1 PEDESTAL MUST BE LOCATED A MINIMUM OF 4 FEET FROM THE WET WELL, 2. CONTROL PANEL CAN BE MOUNTED TO BUILDING WALL, PER OWNER'S DISCRETION. PANEL MUST BE WITHIN 50 FT. OF STATICN. CONTROL PANEL PEDESTAL (OPTIONAL) 120 VAC 0 M I R3 S1 3 - - t I PLI -1b DO 4 9 10 , i OL 1 7 MAIN ,OWN ECT DISC MODE IRS 2 R5 R4 _71� THERM It ETM TO BE 1_1 PROVIPED R3 PL2 �G BY OTHERS R4 C8 L_,�tb 13 )±%, F160,L 2 4r 1_2 THERM ETM 1_3 BM :5) 2 ALT B2 BC BR GR BE R2 5 17 R ALARM LIGHT 30t nGH LEVEL Rol 18 4 HORN _E T T T I L SILENCE 21 (RI 208/23OV, 3 PHASE, 60 HZ `0 0 I 1_1 - 115V TO GROUND 62 KOHMS TOTAL RESISTANCE A/\N\,- 62 KOHMS TOTAL RESISTANCE XFMR — 24VAC 2 AMP il FS4 32 1 2 20 F.q_1 TEST 33 SECURE TO PIPE SUPPORT WITH TWO STAINLESS STEEL HOSE CL 3�4" REDUCED PRESSURE BACKFLOW P EVENTOR (BY CONTRACTOR)_�" BALL VALVE WITH TEST COCK (TYPICAL) SEE NOTE #2 ___1j I ICN SEE NOTE #1 34 3a OFF I WIRE COLOR CODE (#,CLR) 0 - BLACK 1 - BROWN 2 - RED 3 - ORANGE 4 - YELLOW 5 - GREEN 6 - BLUE 7 - PURPLE 8 - GRAY 9 - WHITE CONTROL PANEL SCHEMATIC 3/4" HOSE BIBB FINISH GRADE 2" GALVANIZED SUPPORT PIPE FILLED WITH CONCRETE UPTES: 1. 1" POLYETHYLENE TUBING SDR 9 COPPER TUBE SIZE. 2, LANDSCAPING REQUIRED PER CITY OF FORT PIERCE OR ST. LUCIE COUNTY ORDINANCE. NO PLANTS OR TREES WITHIN 18" AROUND METER & BACKFLOW. NO SOLDER JOINTS, HOSv BIBB-.Y 1:1 -/RPZ BACKELOW PREVENTER R E V I S 1 0 IN S BY DATE LIFT STATION AND WATER & SEWER DETAILS ..... .. .. ... DOYLE PROPERTIES, LLC BY DATE DRAWN JOE M 10/27/17 DESIGNED RCL 10/20/17 CHECKED RCL 11/03/17 OA/QC RML 4/04/18 SU RVEY REF. NAME ' 17.3066 JORAWING 2016-66�4-i56b PM TI T2 T3 11 12 115 TO CONTROL mi M2 9.5 FLA 9.5 FLA 2 HP 2 HIP NOTES: 1� PANEL MUST BE GROUNDED IN ACCORDANCE WITH LOCAL, STATE, AND NATIONAL CODES 2 A GROUNDED SYSTEM NEUTRAL MUST BE SUPPLIED (GROUNDING TO BE IN ACCORDANCE WITH NAT10NAL ELECTRIC CODE ARTICLE 250) 3) USE COPPER CONDUCTORS RATED 50deg C IF RATED LESS THAN 100 AMPS; 75deg C IF RATED 100 AMPS OR MORE 4 ALL CONDUITS MUST ENTER FROM BOTTOM 5 TERMINAL TIGHTENING TORQUE REQUIREMENTS FOR NEUTRAL, GROUND AND INCOMIING POWER CONNECTIONS ARE AS FOLLOWS: 35LB-IN FOR #18-#IOAWG; 40LB-IN FOR 6) IBAWG; AND 45LB-IN FOR16-#4AWG ERMINAL TIGHTENING TORO [E REQUIREMENTS FOR #18AWG PUMP CONTROL CABLES AND FLOATS ARE 20LB-IN 7) MAIN & EMERGENCY BREAKERS ARE MECHANICALLY INTERLOCKED TO PREVENT SIMULTANEOUS OPERATION B)GENERATOR POWER REQUIREMENT IS 7KW CONTINUOUS OUTPUT WITH 30 AMPERE RATING I 20e/23OV, 3 PHASE, 60HZ. CONTROL PANEL SCHEMATIC VALVE BOX & CO�LAR USF # 7535 4 MOUNT BRONZE DISC WITH VALVE NOMENCLATURE 3" POLYETHELYNE CAM LOCK ASS' W/ VENTED AIR RELEASE M. 8 AX, : 4 12� 21"GALVANIZED NIPPLE-� SCHEDULE 80 PvC ivirr��j 45* PVC BENDSi 2" RESILIENT SEAT GATE VALVE---/ SECTION A -A PUMPOUT CONNECTION ATLANTIC CIVIL ENGINEERING, INC. CONSULTING ENGINEERS 2552 PETERS ROAD SUITE D FORT PIERCE, FLORIDA 34945 :(772) 398-1520 PHONE (772) 398-1521 FAX CERTIFICATE OF AUTHORIZATION #32020 I DATE: 3/23/18 HORIZ SCALE: 1"=40- VERT SCA1 F- N/A RICHARD .E. JOB No.2017-0109 SHEET 7 OF 8 �� - SURPLEMENTARY QQNDI-noNs PERMITS AND LICENSES: CONSTRUCTION PERMITS FOR CERTAIN ELEMENTS OF THE PROJECT WORK HAVE BEEN OBTAINED OR APPLIED FOR BY THE OWNER, AMD THE DESIGN AND CONSTRUCTION REQUIREMENTS OF THE PROJECT REFLECT CONSTRAINTS AND CONDITIONS IMPOSED BY THESE PERMITS. THE CONTRACTOR SHALL PERFORM HIS WORK AND SHALL CONSTRUCT THE PROJECT IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PERMITS AND APPROVALS, COPIES OF WHICH ARE AVAILABLE FOR HIS REVIEW AND USE FROM THE ENGINEER, UPON REQUEST, THE CONTRACTOR SHALL SECURE ALL WORK PERMITS, APPROVALS OR LICENSES REQUIRED TO PERFORM THE WORK, AND HE SHALL PERFORM THE WORK IN STRICT ACCORDANCE WITH THOSE PERMITS, APPROVALS OR LICENSES. CONTRACTISSUE GENERAL CONDITIONS: UNLESS OTHERWISE STATED IN THESE SUPPLEMENTARY CONDITIONS, THE PROVISIONS OF THE "STANDARD GENERAL CONDITIONS OF THE S TRACT," REFERENCED ABOVE, SHALL BE USED TO GOVERN ALL ISSUES ADDRESSED IN THOSE GENERAL CONDITIONS FOR THIS PROJECT. OWNER -ENGINEER RELATIONSHIP� ANY AGREEMENT BETWEEN OWNER AND ENGINEER SHALL NOT BE CONSTRUED TO PROVIDE ANY OBLIGATION FROM THE ENGINEER TO ANY THIRD PARTIES INCLUDING, BUT NOT LIMITED TO, ANY CONTRACTORS (GENERAL OR SUB), ORS IN TITLE TO THE OWNER. THE RIGHTS UNDER ANY AGREEMENT BETWEEN OWNER AND ENGINEER INURE ONLY TO THOSE TWO PARTIES. PARTIAL PAYMENTS: PARTIAL PAYMENTS SHALL BE CALCULATED FROM QUANTITIES OF WORK IN PLACE. THESE PAYMENTS SHALL BE BASED ON THE AGREEMENT UNIT PRICES AND WILL BE MADE ON OR ABOUT THE 15TH OF EACH MONTH FOR THE PREVIOUS MONTH'S PROGRESS. THE CONTRACTOR SHALL, AFTER THE FIRST OF EACH MONTH, SUBMIT INVOICES FOR MATERIALS USED AND WORK PERFORMED FOR THE PREVIOUS MONTH. THE ENGINEER WILL REVIEW ALL INVOICES ALONG WITH RECORD DRAWINGS AND FIELD NOTES TO DATE BEFORE PRESENTING THEM TO THE OWNER FOR PAYMENT. TEN PERCENT (10%) OF THE AMOUNT DUE AND PAYABLE TO THE CONTRACTOR WILL BE RETAINED FROM EACH PARTIAL PAYMENT. FINAL PAYMENTS WILL BE ACCOMPLISHED AS PRESCRIBED IN THE AGREEMENT. THE DRAWING ERRORS OR OMISSIONS IN THE DRAWINGS OR SPECIFICATIONS: PRIOR TO INITIATION OF THE WORK, THE CONTRACTOR SHALL CHECK DIMENSIONS, GRADES, ELEVATIONS AND THE SUMMARY OF ESTIMATED QUANTITIES SHOWN ON THE DRAWINGS TO ASSURE HIMSELF THAT THEY ARE CORRECT AND THAT THE WORK CAN BE ACCOMPLISHED AS INTENDED. THE CONTRACTOR SHALL TAKE NO ADVANTAGE OF ANY APPARENT ERROR OR OMISSION WHICH HE MIGHT DISCOVER, BUT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF SUCH DISCOVERY, WHO WILL THEN MAKE SUCH CORRECTIONS AND INTERPRETATIONS AS HE DEEMS NECESSARY FOR REFLECTING THE ACTUAL SPIRIT AND INTENT Or THE DRAWINGS AND SPECIFICATIONS, SOIL AND SUBSOIL CONDITIONS: IT IS THE SOLE AND EXCLUSIVE RESPONSIBILITY OF THE CONTRACTOR TO: 1. PLACE HIS OWN INTERPRETATION ON ANY AND ALL SOIL AND SUBSOIL DATA RAWINGS OR THIS PROJECT MANUAL. 2, PERFORM HIS OWN SOIL AND SUBSOIL INVESTIGATION TO DETERMINE THE NATURE, CHARACTER, LOCATION AND EXTENT OF ALL SOIL AND SUBSOIL CONDITIONS THAT MAY AFFECT HIS WORK; AND 3. INCLUDE IN HIS CONTRACT PRICE CONSIDERATION FOR ALL WORK NECESSARY TO ASSURE THAT THE SOIL AND SUBSOIL CONDITIONS WILL MEET THE REQUIREMENTS OF THE SPECIFICATIONS AND THE APPLICABLE REGULATIONS OF THE CITIES OF ST. LUCIE WEST PORT ST. LUCIE AND ST. LUCIE COUNTY. THE WOR PRE-CONSTRUCTON CONFERENCE: IMMEDIATELY AFTER THE AGREEMENT HAS BEEN AWARDED, THE ENGINEER SHALL CALL A PRE- CONSTRUCTION CONFERENCE TO BE HELD WITHIN FIFTEEN (15) CALENDAR DAYS AFTER THE AWARE) AND PRIOR TO INITIATION OF THE WORK AT A PLACE DESIGNATED TO HIM, TO REVIEW THE CONSTRUCTION ASPECTS OF THE PROJECT, THE MEETING WILL BE BETWEEN THE ENGINEER, OWNER AND THE CONTRACTOR. THE CONTRACTOR SHALL PRESENT HIS TENTATIVE DETAILED WORKING SCHEDULE FOR THE PROJECT SO THAT IT MAY BE REVIEWED BY THE ENGINEER AND OWNER. ADDITIONALLY, IT WILL AFFORD THE CONTRACTOR AN OPPORIUNITY TO HAVE ANY QUESTIONS HE MAY HAVE ON THE WORK CLARIFIED BY THE ENGINEER. NO WORK UNDER THE AGREEMENT SHALL COMMENCE UNTIL AFTER THE NOTICE TO PROCEED HAS BEEN ISSUED. COMMENCEMENT AND COMPLETION OF THE WORK: THE CONTRACTOR SHALL COMMENCE WORK UNDER THE AGREEMENT WITHIN TEN (10) CALENDAR DAYS AFTER THE DAY OF RECEIPT HY HIM OF THE NOTICE TO PROCEED AND SHALL COMPLETE THE WORK READY FOR USE NOT LATER THAN THE TIME INDICATED IN THE AGREEMENT. THE TIME STATED FOR COMPLETION SHALL INCLUDE FINAL CLEANUP OF THE PREMISED, ESTIMATED QUANTITIES: THE QUANTITIES ESTIMATED FOR VARIOUS ITEMS OF WORK ARE ONLY ESTIMATES, AND MAY NOT REFLECT ALL THE ITEMS OF WORK OR THE FINAL QUANTITIES NEEDED TO COMPLETE THE PROJECT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DO ALL WORK AND TO FURNISH AND INSTALL ALL IMPROVEMENTS SHOWN ON THE DRAWINGS. WHETHER OR NOT THEY ARE SHOWN IN THE ESTIMATED OIJANTITIES. OR WHETHER THE FINAL QUANTITIES ARE MORE OR LESS THAN THOSE E"MATED. HORIZONTAL AND VERTICAL CONTROL: THE CONTRACTOR SHALL CONSTRUCT THE REQUIRED IMPROVEMENTS IN THE LOCATIONS SHOWN ON THE DRAWINGS, AND SHALL USE AS HORIZONTAL CONTROL POINTS THE EXISTING PROPERTY CORNERS AS SHOWN ON THE PLANS. THE HORIZONTAL CONTROL POINTS WERE PROVIDED BY LAVENTURE AND ASSOCIATES, INC., (772-398-6430). As VERTICAL CONTROL, BENCHMARKS SHALL BE PROVIDED AT THE SITE, FQR USE IN ESTABLISHING THE NECESSARY ELEVATIONS AND GRADES AT THE LOCATIONS SHOWN ON THE PLANS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT ALL CONTROL POINTS AND TO REESTABLISH SAID POINTS AS NECESSARY. REMAINING HORIZONTAL AND VERTICAL CONTROL WORK SHALL BE PERFORMED BY THE CONTRACTOR. THE VERTICAL CONTROL POINTS FOR THIS PROJECT WERE PROVIDED BY LAVENTURE AND ASSOCIATES, INC., (772-398-6430). COORDINATION OF WORK WITH OTHERS: THE CONTRACTOR SHALL COORDINATE HIS WORK WITH THE WORK OR IMPROVEMENTS OF OTHERS WITH REGARD TO NEW CONSTRUCTION, OR FOR THE NEED OF REMOVAL, RELOCATION OR ALTERATION OF EXISTING FACILITIES. THIS INCLUDES, BUT IS NOT LIMITED TO, THE QWNER, SOUTHERN BELL TELEPHONE & TELEGRAPH, TCI UNITED ARTISTS CABLE VISION COMPANY, ST. LUCIE COUNTY UTILITIES, CENTRAL FLORIDA CELLULAR PHONE COMPANY, ST, LUCIE COUNTY ENGINEERING DEPARTMENT AND THEIR CONTRACTORS, SUBCONTRACTORS OR AGENTS. STANDARDS FOR QUALITY AND WORKMANSHIP: ALL MATERIALS, EQUIPMENT AND SUPPLIES FURNISHED BY THE CONTRACTOR FOR PERMANENT INCORPORATION IN THE WORK SHALL BE NEW AND OF THE QUALITY STANDARDS SPECIFIED. WORKMANSHIP SHALL BE FIRST-CLASS AND THE FINISHED PRODUCT EQUAL To THE BEST ACCEPTED STANDARDS OF THE TRADE FOR THE CATEGORY OF WORK PERFORMED. TEMPORARY UTILITIES: ALL ARRANGEMENTS AND COSTS FOR TEMPORARY POWER, WATER AND WASTEWATER FACILITIES DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. OBSERVNG THE WORK: THE PROGRESS AND QUALITY OF THE WORK WILL BE OBSERVED BY THE OWNER'S ENGINEER OR ENGINEER'S APPOINTED EMPLOYEE. NO OBSERVER IS AUTHORIZED TO CHANGE ANY PROVISIONS OF THE SPECIFICATIONS WITHOUT WRITTEN AUTHORIZATION OF THE OWNER'S ENGINEER, NOR SHALL THE PRESENCE AND/ OR THE ABSENCE Or AN THE CONTRACTOR FROM ANY REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS. ALL GIVE THE ENGINEER A MINIMUM OF 24 HOURS NOTICE PRIOR TO REQUIRED INSPECTIONS, AND SHALL SUPPLY ALL EQUIPMENT NECESSARY TO PROPERLY TEST AND INSPECT THE COMPLETED WORK. IN ADDITION TO THE REQUIREMENTS PREVIOUSLY REFERENCED, THE FOLLOWING MINIMUM CONSTRUCTION CONTROL CHECKPOINTS SHALL BE ADHERED TO, AND THE CONTRACTOR SHALL NOTIFY THE ENGINEER FOR OBSERVATION: 1. PRIOR TO ANY DEVIATION FROM THE DRAWINGS; 2. PRIOR TO ANY BACK FILLING TRENCHES CONTAINING HYDRAULIC CONDUITS, SO THE JOINTING MAY BE INSPECTED; 3. PRIOR TO TESTING OF ALL HYDRAULIC CONDUITS. 4. PRIOR TO PLACEMENT OF ROADWAY BASE MATERIAL, CONCRETE OR ASPHALTIC CONCRETE. 5. UPON COMPLETION OF CONSTRUCTION FOR FINAL INSPECTION WITH THE CONTRACTOR OR HIS REPRESENTATIVE. TESTING: IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE INDEPENDENT TESTING LABORATORY DESIGNATED BY THE OWNER, THE TESTING AND RMED TO STRICT COMPLIANCE WITH THE SPECIFICATIONS, COST FOR THE INITIAL TESTING SHALL BE BORNE BY THE OWNER. ANY RETESTS REQUIRED DUE TO FAILURE TO MEET THE MINIMUM REQUIREMENTS SHALL BE RACTOR. THE NAME OF THE OWNER'S TESTING LABORATORY SHALL BE SUPPLIED AT THE PRE CONSTRUCTION MEETING, EXISTING UTILITIES AND STRUCTURES: EXISTING UTILITIES, STRUCTURES AND FACILITIES SHOWN ON THE DRAWINGS WERE LOCATED AS ACCURATELY AS POSSIBLE FROM THE RECORDS EXAMINED. NO GUARANTEE IS MADE THAT ALL EXISTING FACILITIES ARE SHOWN OR THAT THOSE SHOWN ARE ENTIRELY ACCURATE. THE CONTRACTOR SHALL ASSURE HIMSELF OF THE ACTUAL LOCATION OF THE UTILITIES, STRUCTURES OF FACILITIES PRIOR TO PERFORMANCE OF ANY WORK IN THE VICINITY. THE UTILITY COMPANIES OR UTILITY AGENCIES WILL COOPERATE WITH THE CONTRACTOR IN LOCATING UNDERGROUND UTILITIES THAT MAY BE SUBJECT TO DAMAGE OR INTERRUPTION OF SERVICES DURING THE CONTRACTOR'S OPERATIONS. PRIOR TO START OF THE WORK, THE CONTRACTOR SHALL REQUEST THAT EACH UTILITY AGENCY ADVISE HIM OF THE LOCATION OF THEIR FACILITIES IN THE VICINITY. THE OWNER WILL ASSUME NO LIABILITY FOR DAMAGES SUSTAINED OR COSTS INCURRED BECAUSE OF THE CONTRACTOR'S OPERATION IN THE VICINITY OF EXISTING UTILITIES OR STRUCTURES, OR TO THE TEMPORARY BRACING AND SHORING OF SAME. IN THE EVENT THAT IT IS NECESSARY TO SHORE, BRACE, OR SWING A UTILITY, THE UTILITY COMPANY OR DEPARTMENT AFFECTED CONTACTED AND THEIR PERMISSION SECURED AS TO THE METHOD USED FOR ANY SUCH WORK. R UTILITIES: IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR, REBUILD OR RESTORE TO ITS FORMER CONDITION, ANY AND ALL PORTIONS OF EXISTING UTILITIES, STRUCTURES, EQUIPMENT, APPURTENANCES OR FACILITIES, OTHER THAN THOSE TO BE PAID FOR UNDER THIS CONTRACT, WHICH MAY BE DISTURBED OR DAMAGED DUE TO THIS CONSTRUCTION OPERATION, AT NO COST TO THE OWNER. FINAL CLEANUP: UPON COMPLETION OF THE WORK BUT BEFORE FINAL PAYMENT WILL BE MADE, THE CONTRACTOR SHALL CLEAR AND REMOVE FROM THE PROJECT AREA, ALL FALSE WORK, EQUIPMENT, SURPLUS AND DISCARD MATERIALS, RUBBISH AND TEMPORARY STRUCTURES WHICH RESULT FROM THE WORK UNDER THIS AGREEMENT, AND SHALL RESTORE IN AN ACCEPTABLE MANNER ALL PROPERTY WHICH HAS BEEN DAMAGED DURING THE PROSECUTION OF THE WORK. RECORD DRAWINGS: AFTER COMPLETION OF THE CONTRACT WORK, BUT PRIOR TO SUBMITTAL FINAL PAYMENT, THE CONTRACTOR SHALL PROVIDE ALL INFORMATION OR PREPARATION OF FINAL RECORD DRAWINGS FOR SUBMITTAL TO THE OWNER OF THE COMPLETED IMPROVEMENTS. THE INFORMATION SHALL INCLUDE FINAL LOCATION, BY REFERENCE TO COMPLETED IMPROVEMENTS, OR OTHER ACCEPTABLE MEANS, OF ALL UNDERGROUND OR SUBMERGED IMPROVEMENTS, THE ELEVATIONS OF PERTINENT POINTS IN THE DRAINAGE, WATER AND WASTEWATER SYSTEMS, ACTUAL CONSTRUCTED PIPE LENGTHS, SLOPES AND INVERTS, CUTOFF WALL DIMENSIONS AND ELEVATIONS, ALL REVISIONS TO THE ORIGINAL PLANS, AND ALL INFORMATION NECESSARY TO LOCATE AND OPERATE THE IMPROVEMENTS CONSTRUCTED UNDER THIS AGREEMENT, PAYMENT FOR OBTAINING AND PROVIDING THE RECORD DRAWING INFORMATION SHALL BE INCLUDED IN THE CONTRACT UNIT PRICES FOR THE VARIOUS ITEMS OF WORK TO WHICH IT IS INCIDENTAL. THE CONTRACTOR SHALL COORDINATE THE CONSTRUCTION, SO THAT THE ENGINEER'S REPRESENTATIVE IS PRESENT AND CAN CONFIRM THE RECORD INFORMATION As FOLLOWS. I THE FINAL LOCATION, BY REFERENCE TO AT LEAST TWO COMPLETED VISIBLE IMPROVEMENTS OR OTHER PERMANENT POINTS, OF ALL PAVING, DRAINAGE, WATER DISTRIBUTION SYSTEM AND WASTEWATER COLLECTION SYSTEM ELEMENTS, AND SHALL INCLUDE ELEVA71ONS OF PERTINENT POINTS IN TE PAVEMENT AND DRAINAGE IMPROVEMENTS, ALL REVISIONS TO THE ORIGINAL PLANS, VERIFICATION OF ALL DESIGN DIMENSIONS, ELEVATIONS, PIPE SLOPES, PIPE LENGTHS AND ALL OTHER INFORMATION NECESSARY TO HORIZONTALLY AND VERTICALLY LOCATE AND OPERATE THE IMPROVEMENTS CONSTRUCTED UNDER THIS CONTRACT. INFORMATION TO BE SHOWN FOR THE WATER DISTRIBUTION SYSTEM INCLUDES THE LOCATION SERVICE TERMINALS, FOR THE WASTEWATER COLLECTION SYSTEM INCLUDES THE LOCATION OF ALL SERVICE TERMINALS, AND THE LOCATION OF ALL ELECTRICAL AND COMMUNICATION CONDULT. DRAWINGS SHALL INCLUDE: A. ANY CHANGES OR VERIFICATIONS GET MARKED B. MARK OUT ALL "PROPOSED" OR "CONSTRUCTS" C. CHANGES TO LOCATIONS OF PIPE, VALVES, FITTINGS OR MANHOLES, ETC. D. DRAW IN A DETAIL BOX OF ANY SUBSTANTIAL CHANGES E. MARK LOCATIONS AND FOOTAGE OF ALL LATERALS FROM THE DOWNSTREAM MANHOLE F. MARK ALL BSP'S ON PLANS GUARANTEE: ALL MATERIALS AND THE INSTALLATION THEREOF WHICH ARE FURNISHED AND INSTALLED BY THE CONTRACTOR, UNDER THE TERMS OF THE AGREEMENT, SHALL BE GUARANTEED BY THE CONTRACTOR AGAINST DEFECTIVE WORKMANSHIP, MECHANICAL AND PHYSICAL DEFECTS, LEAKAGE, BREAKAGE, AND OTHER DAMAGES AND FAILURE UNDER NORMAL OPERATION FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL PAYMENT, SAID DATE TO CONSTITUTE THE COMMENCEMENT OF THE ONE (1) YEAR WARRANTY PERIOD, ALL MATERIALS AND INSTALLATIONS PROVING TO BE DEFECTIVE WITHIN THE SPECIFIED PERIOD OF THE GUARANTEE SHALL BE REPLACED, WITHOUT COST TO THE OWNER, BY THE CONTRACTOR. THE PERIOD OF GUARANTEE OF EACH SUCH REPLACEMENT SHALL BE FROM AND AFTER THE DATE IN INSTALLATION THEREOF, MATERIALS, CONSTRUCTION METHODS. TESTING AND TOLERANCES FOR ALL WORK SHALL BER IN ACCORDANCE WITH THE FOLLOWING SPECIFICATIONS. IN THE EVENT OF A CONFLICT, THE MORE STRINGENT PROVISION SHALL APPLY. 1. MOBILIZATION: THE WORK SPECIFIED IN THIS SECTION CONSISTES OF THE AND OPERATIONS IN MOBILIZING FOR BEGINNING WORK ON THE PROJECT, INCLUDING, BUT NOT LIMITED TO, THOSE OPERATIONS NECESARY FOR THE MOVEMENT OF PERSONNEL, EQUIPMENT, SUPPLIES AND INCIDENTALS TO THE PROJECT SITE, AND FOR THE ESTABLISHMENT OF TEMPORARY OFFICES, BUILDINGS, SAFETY EQIUPMENT AND FIRST AID SUPPLIES, SANITARY AND OTHER FACILITIES, AS REQUIRED BY THESE SPECIFICATIONS, THE SPECIAL PROVISIONS, AND STATE AND LOCAL LAWS AND REGULATIONS. ALL COSTS FOR BONDS, PERMITS AND ANY REQUIRED INSURANCE, AND ANY OTHER PRECONSTIRCUTION EXPENSE NECESSARY FOR THE START OF THE WORK, AS WELL THE COST OF THE REMOVAL OF THE ABOVE ITMES. SHALL ALSO BE INCLUDED IN THIS SECTION. 2. CONSTRUCTION SURVEYING: THE CONTRACTOR SHALL CONSTRUCT THE REQUIRED IMPROVEMENTS AT THE LOCATIONS SHOWN ON THE PLANS. AS OUTLINED IN THE SUPPLEMENTARY CONDITIONS, THE OWNER SHALL PROVIDE BASIC REFERENCE POINTS FOR HORIZONTAL CONTROL AND BENCHMARKS IN THE VICINITY OF WORK, ALL OTHER CONSTRUCTION STAKING FOR BOTH HORIZONTAL AND VERTICAL CONTROL NEEDED BY THE CONTRACTOR FOR CONTROL OF HIS WORK SHALL BE PERFORMED BY THE CONTRACTOR. 3. CLEARING AND GRUBBING: CLEARING AND GRUBBING SHALL BE PERFORMED WITHIN THE LIMITS OF CONSTRUCTION AS SHOWN ON THE PLANS, INCLUDING OUT NOT LIMITED TO, THE AREAS OF NEW SIDEWLAKS, SWALES, POND, ROADWAY AND PARKING PAVEMENT, AND BUILDING AREA IN ACCORDANCE WITH SECTION 110, DOR SPECIFICATION, AND SHALL CONSIST OF THE COMPLETE REMOVAL AND DISPOSAL OF ALL TREES, BRUSH, STUMPS, ROOTS, GRASS, WEEDS, RUBBISH, AND ALL OTHER OBSTRUCTIONS TO A DEPTH OF 18 INCHES BELOW NATURAL GROUND OR DESIGN GRADE, WHICHEVER IS LOWER, ALL MATERIAL SHALL BE REMOVED FROM THE SITE OF THE PROJECT, AND SHALL BE DISPOSED OF IN ACCORDANCE WITH ALL LOCAL, REGIONAL, STATE. AND FEDERAL LAWS, REGULATIONS, AND ORDINANCES. 4. EARTHWORK AND GRADING: SHALL BE PERFORMED AS REQUIRED TO ATTAIN THE FINAL GRADES, TYPICAL SECTIONS AND ELEVATIONS, AND TO ACCOMPLISH THE OBJECTIVES SHOWN ON THE PLANS FOR THE AREAS TO BE PAVED, SODDED, OR LANDSCAPED. MATERIALS AND CONSTRUCTION METHODS SHALL MEET THE REQUIREMENTS OF SECTION 120 FDOR SPECIFICTIONS. ANY PLASTIC OR ORGANIC MATERIAL WITHIN 36" OF THE FINISHED GRADE OF THE AREA E REMOVED AND REPLACED WITH A-3 MATERIAL. EMBANKMENT ORMED IN ACCORDANCE WITH FDOR SPECIFICATIONS, ALL CLEAN EXCESS MATERIAL SUITABLE FOR FILL RESULTING FROM THE EXCAVATION SHALL BE INCORPORATED INTO THE PROPOSED WORK, OR SHALL REMAIN THE PROPERTY LL BE STOCKPILED ON THE OWNERS PROPERTY AT THE ONSITE LOCATION DESIGNATED BY THE OWNER, ALL UNSUITABLE MATERIAL AND DEBRIS SHALL BE REMOVED AND DISPOSED OF BY THE CONTRACTOR. THE WORK SHALL INCLUDE, BUT NOT LIMITED TO THE FOLLOWING: FINAL GRADING OF THE POND, SWALES, SIDEWALKS, ROADWAY, PARKING LOT, AND FILLING OF EXISTING DITCHES. 5. DRAINAGE IMPROVEMENTS: THE CONTRACTOR SHALL PROVIDE ALL MATERIALS AND O COMPLETE THE PRO RAINAGE IMPROVEMENTS AT THE LOCATION, SIZE AND TYPE SHOWN ON THE PLANS FOR THE FOLLOWING ITEMS. INCLUDED IN THE UNIT COSTS FOR EACH ITEM SHALL BE THE COSTS ASSOCIATED WITH THE DESIGN AND CONSTRUCTION, BY THE CONTRACTOR, TO COMPLY WITH THE TRENCH SAFETY ACT, LAWS OF FLORIDA, CHAPTER 90-96. BACKFILL AND COMPACTION OF TRENCHINF FOR CULVERT INSTALLATION UNDER THIS SECTION SHALL BE IN ACCORDANCE WITH SECTION 125-8.3, FOOT SPECIFICATIONS, DENSITY TESTS SHALL BE PROVIDED AT THE FOLLOWING VERTICAL LOCATIONS: TWO TESTS* AT SPRINGLINE (ONE EACH SIDE OF PIPE) ONE TEST* AT ONE FOOT ABOVE PIPE; AND ONE TEST* AT ONE FOOT BELOW SUBGRADE OR FINISH GRADE. * - DENSITY OF AT LEAST 98 % OF MAXIMUM DENSITY AS DETERMINED BY AASHTO T-180 THE MINIMUM NUMBER OF HORIZONTAL TEST LOCATIONS IS TWO PER CULVERT INSTALLATION, ONE PER 100 LINEAR FEET OF PIPE AND/OR ONE PER 20 FEET OF PAVEMENT CROSSING WHICHEVER IS GREATER. ADDITIONAL TESTS MAY BE REQUIRED AT MORE FREQUENT INTERVALS IF DEEMED NECESSARY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TOO COORDINATE THE INDEPENDANT TESTING LABORATORY DESIGNATED BY THE OWNER, THE TESTING AND RETESTING NECESSARY TO ASSURE THAT THE WORK HAS BEEN PERFORMED IN STRICT COMPLIANCE WITH THESE ACTIONS, COST FOR THE INITAL TESTING SHALL BE BORNE BY THE OWNER. ANY RETEST REQUIRED DUE TO FAILURE TO MEET THE MINIMUM REQUIRIEMENTS ABOVE SHALL BE PERFORMED AT THE EXPENSE OF THE CONTRACTOR. DOYLE PROPERTIES, LLC A. STORM SEWER PIPE: CONSTRUCTION METHODS FOR DRAINAGE CULVERTS SHALL UIREMENTS OF SECTIONS 125 AND 4,30, FOOT SPECIFICATIONS. ETE PIPE (RCP): MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF SECTION 941, FOOT SPECIFICATIONS FOR STANDARD CONCRETE PIPE AND SECTION 942, FOOT SPECIFICATIONS FOR CASKETS. B. STORM INLETS: THE MATERIALS AND CONSTRUCTION METHODS FOR STORM INLETS AND GRATES SHALL CONFORM TO SECTION 425, FDOT SPECIFICATIONS. TYPE "C" AND "E" INLETS SHALL BE PER FOOT INDEX NO. 232. INLETS AND PAVED AREAS SHALL HAVE STEEL GRATES SUITABLE FOR HEAVY TRAFFIC AND BICYCLES, CAST IRON TRAFFIC GRATES IN ALL OTHER AREAS, C. CONCRETE CURSING: THE CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS TO CONSTRUCT THE CONCRETE CURBING IN THE LOCATIONS SHOWN ON THE PLANS. ALL CURSING SHALL BE CONSTRUCTED PER FOOT INDEX NO. 300. MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO SECTION 520, FOOT SPECIFICATIONS. SUBGRADE UNDER AL HALL HAVE A MINIMUM LBR OF 40. 6. PAVEMENT IMPROVEMENTS: THE CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS NECESSARY TO COMPLETE THE ITEMS OF WORK FOR PAVING IMPROVEMENTS UNDER THIS SECTION AT THE LOCATIONS AND TO THE EXTENT SHOWN ON THE PLANS. PAVEMENT RESTORATION SHALL BE CONSTRUCTED AS SHOWN ON THE PLANS, AND IN ACCORDANCE WITH THESE SPECIFICATIONS, FOOT, AND ST. LUCIE COUNTY SPECIFICATIONS. A. STABILIZED SUBGRADE SHALL HAVE A MINIMUM LBR RATIO OF 40, AND MINIMUM DENSITIES SHALL BE 98% OF MAXIMUM AS DETERMINED BY THE AASHTO T-180 METHOD C. MATERIALS AND CONSTRUCTION METHODS SHALL BE FURNISHED BY THE CONTRACTOR, AND CONFORM TO SECTION 160, FOOT SPECIFICATIONS FOR TYPE C STABILIZATION AND PAID FOR AS PART OF THE WORK UNDER THIS SECTION. COMPACTED SUBGRADE WITHIN THE LIMITS SHOWN FOR THE PROPOSED PAVEMENT SHALL BE 12 INCHES IN THICKNESS. STABILIZED SUBGRADE SHALL EXTEND 6 INCHES BEYOND THE E URSE. 7. CONCRETE NOTES: IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE INDEPENDENT TESTING LABORATORY DESIGNATED BY THE OWNER, THE TESTING AND RETESTING NECESSARY TO ASSURE THE WORK HAS BEEN PERFORMED TO STRICT COMPLIANCE WITH THE SPECIFICATIONS, COST FOR THE INITIAL TESTING SHALL BE BORNE BY THE OWNER, ANY RETESTS REQUIRED DUE TO FAILURE TO MEET THE MINIMUM REQUIREMENTS SHALL BE PERFORMED HE CONTRACTOR, MINIMUM TESTING DETERMINATION FOR ALL ITEMS OF TE AREA SHALL BE AS FOLLOWS: FLORIDA SOIL ITEM BEARING VALUE DENSITY THICKNESS SUBGRAIDE 500* 500* 100* CONCRETE .- - 200* *=MAXIMUM SPACING SHOWN IN FEET. ALL TESTING SHALL BE TAKEN IN A STAGGERED SAMPLING PATTERN FROM A POINT 12 INCHES INSIDE THE FIRST EDGE, TO THE CENTER, TO A POINT 12 INCHES INSIDE THE RIGHT EDGE OF THE ITEM TESTED. ADDITIONAL TESTS MAY BE REQUIRED FOR THE DRIVEWAY CONSTRUCTION OR AT MORE FREQUENT INTERVALS AS BY THE ENGINEER. 5, PAVEMENT MARKINGS: THE CONTRACTOR SHALL PROVIDE ALL NECESSARY MATERIALS AND LABOR REQUIRED TO COMPLETE THE PROJECT WORK IN THIS SECTION. MATERIALS AND CONSTRUCTION METHODS FOR APPLYING PAINTED ND MARKINGS, COMPLETE WITH REFLECTIVE GLASS APHERES, $HALL CONFORM TO THE REQUIREMENTS OF SECTION 710, FOOT SPECIFICATIONS, TRAFFIC PAINT SHALL BE APPLIED IN ALL LOCATIONS SHOWN ON THE PLANS. 9. SIGNAGE: THE CONTRACTOR SHALL PROVIDE ALL MATERIALS AND LABOR NEEDED, INCLUDING ALL SUPPORTING ELEMENTS, TO INSTALL SIGNS AT THE LOCATIONS SHOWN ON THE PLANS. MATERIALS AND CONSTRUCTION METHODS ECTION 700, FDOT SPECIFICATIONS, STOP SIGNS ARE TO BE HIGH INTENSITY REFERENCE PER FOOT STANDARDS, ST. LUCIE COUNTY SPECIFICATIONS AND THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES. 10, EROSION CONTROL: THE CONTRACTOR SHALL TAKE SUFFICIENT PRECAUTIONS TO PREVENT WATER POLLUTION WITH AQUATIC WEEDS, FUELS, OILS, BITUMINOUS, CALCIUM CHLORIDE OR OTHER HARMFUL MATERIALS. ALSO, HE SHALL ULE HIS OPERATIONS SO AS TO AVOID POLLUTION OR SILTATION OF WATER BODIES OR TO INTERFER WITH INDIGENOUS WILDLIFE. THE INSTALLATION OF TEMPORARY EROSION AND POLLUTION CONTROL FEATURES SHALL BE COORDINATED WITH THE CONSTRUCTION OF THE PERMANENT EROSION CONTROL FEATURES TO THE EXTENT RE ECONOMICAL, EFFECTIVE AND CONTINUOUS CONTROL OF EROSION AND WATER POLLUTION THROUGHOU) THE LIFE OF THE CONTRACT. ANY EROSION OR SHOALING SHALL BE CORRECTED BY THE CONTRACTOR AT HIS EXPENSES. DUE TO UN.,NTICIPATED CONDITIONS, THE ENGINEER MAY DIRECT THE USE OF CONTROL FEATURES OR METHODS OTHER THAN THOSE INCLUDED IN THE ORIGINAL CONTRACT. IN SUCH EVENT THIS ADDITIONAL WORK WILL BE PAID FOR AS RK. OD SHALL BE PROVIDED AS SHOWN ON THE PLANS, INCLUDING BUT NOT LIMITED TO, ALL DISTURBED AREAS. MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO THE REQUIREMENTS FOUND IN LANDSCAPE ARCHITECT'S SPECIFICATIONS. 11. POLLUTION CONTROL: WATER POLLUTION AND TURBIDITY CONTROL SHALL BE REQUIRED BY THE CONTRACTOR IN ACCORDANCE WITH THE DEPARTMENT OF ENVIRONMENTAL REGULATION STANDARDS, LOCAL REGULATIONS AND SECTION 104, FOOT REQUIREMENTS INCLUDING BUT NOT LIMITED TO ONE OR MORE OF THE FOLLOWING OPTIONS; SHEETPILE OR EARTH COFFERDAM, HAY BALES, SEDIMENT BASIN, SILT FENCE OR TURBIDITY BARRIER. EXCAVATED MATERIAL SHALL NOT BE DEPOSITED IN CANALS, OR IN A POSITION CLOSE ENOUGH THERETO, TO BE WASHED AWAY BY HIGH WATER OR RUNOFF, FORT PIERCE UTILITIES AUTHORla WATER DISTRIBUTION NOTES 1. ALL CONSTRUCTION MATERIAL, INSTALLATION AND TESTING SHALL CONFORM TO THE STANDARD SPECIFICATIONS OF THE FORT PIERCE UTILITIES AUTHORITY. 2. WATER MAIN WHERE SPECIFIED AS POLYVINYL CHLORIDE (PVC) SHALL CONFORM TO AWWA C-900 OR C-905, 0, DR (18). WATER MAIN WHERE SPECIFIED AS POLYETHYLENE (PE) SHALL CONFORM TO AWWA C-901 OR C-906, STANDARD CODE DESIGNATION PE3408, PIPE CLASS 200, DIMENSION RATIO (DR) 9� 3. WATER MAIN, WHERE SPECIFIED AS DUCTILE IRON PIPE , SHALL CONFORM TO ANSI A-21.51 OR AWWA C-151, AND SHALL BE PRESSURE CLASS 250 (MINIMUM), 4. POLYVINYL CHLORIDE WATER MAIN SHALL BE BLUE IN COLOR OR WHITE IN COLOR. THE USE OF IDENTIFICATION TAPE ATTACHED TO THE TOP OF THE PIPE MAY BE USED IN LIEU OF MARKING ON THE PIPE, ALSO DIP PIPE SHALL REQUIRE THE USE OF IDENTIFICATION TAPE AND THHN WIRE. 5. FITTINGS SHALL BE CAST OR DUCTILE IRON, CONFORMING TO AWWA C-110 AND ANSI A21.11, CLASS 250 MINIMUM, CEMENT LINED, AND SEAL COATED 6. GATE VALVES SHALL BE MUELLER RESILIENT SEAT, KENNDY KEN-SEAI_, AMERICAN, CLOW, OR APPROVED EQUAL. VALVES SHALL CONFORM TO AWWA C-509. 7. WATER LINES SHALL BE BACKFILLED AND COMPACTED IN ACCORDANCE WITH FPUA DESIGN AND CONSTRUCTION STANDARDS. THE CONTRACTOR SHALL SUBMIT CERTIFIED DENSITY TESTS AS REQUIRED BY FPUA ENGINEERING AND THE CIty, COUNTY, FOOT. IN CASES WHERE PAVED AREAS FALL WTHIN THE JURISDICTION OF LOCAL OR STATE AGENCIES, THE COMPACTION REQUIREMENTS SHALL NOT BE LESS THAN THE MINIMUM REQUIRED BY THE APPROPRIATE RESPONSIBLE AGENCY. 8. NO FIELD CHANGES OR DEVIATIONS FROM THE DESIGN SHALL BE MADE WITHOUT PRIOR APPROVAL OF THE FRUA ENGINEER AND CITY/COUNTY/FDOT ENGINEER. 9. THE CONTRACTOR SHALL NOTIFY FPUA ENGINEERING AND CITY/COUNTY/FDOT ENGINEERING 48 HOURS PRIOR TO COMMENCING CONSTRUCTION, 10. A PRE -CONSTRUCTION CONFERENCE BETWEEN THE ENGINEER, THE CONTRACTOR, FPUA, AND CITY/ COUNTY/FDOT ENGINEER SHALL BE MANDATORY PRIOR TO COMMENCEMENT OF CONSTRUCTION. 11, TRAFFIC CONTROL, BARRICADES, ETC_ SHALL BE IN ACCORDANCE WITH THE FLORIDA DEPARTMENT OF ROVED BY THE CITY ENGINEER. 12. MINIMUM COVER SHALL BE 36 INCHES EXCEPT AS APPROVED BY THE UTILITIES ENGINEER AND CITY/ COUNTY/FDOT ENGINEER, PIPES WITH COVER LESS THAN 30 INCHES SHALL BE CONSTRUCTED OF DUCTILE IRON OR IN PVC CASING. 1 13. DISTURBED AREAS SHALL BE RESTORED IN CONFORMANCE WITH THE APPLICABLE GOVERNING AGENCY REQUIREMENTS. 14. EXISTING UTILITIES AND DRAINAGE SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION AND PROTECTED BY THE CONTRACTOR. 15. WATER MAINS SHALL BE TESTED AND DISINFECTED IN ACCORDANCE WITH THE APPLICABLE FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION AND AWWA C-651 FOR DISINFECTION, - R E V I S I 0 �N S - BY I DATE By DATE I DRAWN .... � .. . JOE M . , . 10/27/17 ..... . DESIGNED I ......., RCL . 10/20/17 ..... CHECKED .. . . . .�6C .. RCL I . . 11/03/17 0 A RM L 4/04/18 SURVEY IREF. DRAWING NAME 0,kO6 12017-0109-GEN-NOTES.dwg ' FORT PIERCE UTILITIES AUTHORITY WATER DISTRIBUTION NOTES CONTINUED 16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING EXISTING UTILITIES AND DRAINAGE, 17. THE CONTRACTOR SHALL FURNISH RECORD DRAWING INFORMATION TO THE ENGINEER INCLUDING LOCATIONS OF VALVES, FITTINGS, SERVICE CONNECTIONS, BLOWOFFS, AIR RELEASE VALVES, AND ANY OTHER PERTINENT INFORMATION NECESSARY TO LOCATE ITEMS CONSTRUCTED UNDER THIS PROJECT, AS REQUIRED BY THE UTILITIES ENGINEER. 18. THE CONTRACTOR SHALL TAP EXISTING LINES UNDER THE SUPERVISION OF THE FORT PIERCE UTILITIES AUTHORITY ONLY AFTER TESTING AND DISINFECTION HAS BEEN COMPLETED AND APPROVED ON THE TAPPING VALVE AND SLEEVE. 19. WATER MAIN SHALL BE MARKED BY THE USE OF CONTINUOUS 10 GAUGE THHN MULTI STRANDED WIRE (BLUE IN COLOR) AND IDENTIFCATION TAPE WITH "WATER" MARKED ON TAPE, PERMANENTLY ATTACHED TO THE TOP OF THE WATER MAIN IN ACCORDANCE WITH THE FORT PIERCE UTILITIES AUTHORITY SPECIFICATIONS. 20. SERVICE TAPS SHALL BE PLACED APPROXIMATELY TEN FEET AWAY FROM GATE VALVES, AS SHOWN, FOR TESTING, FOLLOWING TESTING AND STERILIZATION OF WATER LINE. CONTRACTOR SHALL PLACE A BRASS PLUG IN CORPORATION STOPS AND CURB STOPS SHALL BE REMOVED FROM TESTING LOCATIONS. 21. MECHANICAL RESTRAINTS TO BE USED ON ALL FITTINGS AND PLACED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND FPUA REQUIREMENTS. 22. ALL MAINS SHALL BE TESTED AT A MINIMUM OF 150 PSI, TESTING METHODS SHALL CONFORM TO AWWA C-600. - 2 HR MINIMUM TEST L= jffi3O,51,2 L= LEAKAGE IN GPH S= LENGTH OF PIPE IN FEET D= PIPE DIAMETER IN INCHES P= TESTING PRESSURE IN PSI 23, PRIOR TO ANY TESTING, ALL MAINS 6" IN DIA. AND LARGER SHALL HAVE A LINE SIZE SWAB PASSED THRU THE ENTIRE LENGTH OF THE LINE. NOTE: SWAB SHOULD BE PLACED IN lst. JOINT OF NEW LINE. END OF MAIN SHOULD BE "TURNED UP" AT 457 AND EXTENDED SO THAT SWABBING AND A FULL BORE FLUSH CAN BE ACCOMPLISHED, BLOW -OFF ASSY CAN THEN BE PLACED. WHERE LINES BRANCH, SWABS WILL BE PLACED IN BRANCH LINES AND SEQUENTIALLY SWABBED AND FLUSHED. 24, A MINIMUM SIX FEET AND PREFERABLY TEN FEET HORIZONTAL SEPERATION SHALL BE MAIINTAINED MAIN AND ANY WASTEWATER LINESNCHES MINIMUM VERTICAL SEPARATION IF WATER MAIN IS OVER WASTEWATER AND 12 INCHES IF WATER MAIN IS UNDER SHALL BE MAINTAINED BETWEEN THE WATER MAIN AND ANY WASTWATER LINES. THE DISTANCE SHALL BE SIDE OF PIPE TO OUTSIDE OF PIPE OR STRUCTURE, WHERE THIS MINIMUM SEPARATION CANNOT BE MAINTAINED, THE CROSSING SHALL BE ARRANGED SO THAT THE WASTEWATER PIPE JOINTS AND THE WATER MAIN PIPE JOINTS ARE EQUIDISTANT FROM THE POINT OF CROSSING, AND THE WATER MAIN SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE (DIP) AT THE CROSSING. SUFFICIENT LENGHTS OF DIP MUST BE USED TO PROVIDE A MINIMUM SEPARATION OF 10 FEET BETWEEN ANY TWO JOINTS. ALL JOINTS ON THE WATER MAIN WITHIN 20 FEET OF THE CROSSING MUST BE MECHANICALLY RESTRAINED. A MINIMUM VERTICAL CLEARANCE OF 6 INCHES MUST BE MAINTAINED AT ALL CROSSINGS. 25. WHERE A WATER MAIN IS TO BE INSTALLED BELOW A STORM DRAIN PIPE, A MINIMUM OF 6 INCHES OF VERTICAL CLEARANCE BETWEEN PIPES SHALL BE CONSTRUCTED OF DIP AT THE CROSSING, AND SHALL BE MECHANICALLY RESTRAINED WITHIN 20 FEET OF THE CROSSING. 26, CONTRAC70R SHALL COMPLY WITH FLORIDA TRENCH SAFETY ACT REQUIREMENTS. I glowl mmmmum" 1 1:6-mmaloull ymmmLamy "T Imateley malwal 1. ALL CONSTRUCTION MATERIAL, INSTALLATION AND TESTING SHALL CONFORM TO THE STANDARD SPECIFICATIO14S OF THE FORT PIERCE UTILITIES AUTHORITY. 2, GRAVITY SEWER MAIN SHALL BE POLYVINYL CHLORIDE SOR-35, GREEN OR WHITE IN COLOR, GRAVITY SEWER MAIN SHALL HAVE LOCATOR TAPE WITH "SEWER" MARKED ON TAPE AND SHALL CONFORM TO ASTM D-3034. ,3. THE MANHOLE BASE SHALL BE SET ON A FIRM, DRY AND STABLE OR COMPACTED BASE FOUNDATION. IF NECESSARY, THE CONTRACTOR SHALL UTILIZE ROCK TO PROVIDE A FIRM AND SUITABLE MANHOLE BASE FOUNDATION. 4. WASTEWATER LINES SHALL BE BACKIFILLED AND COMPACTED IN ACCORDANCE WITH FPUA DESIGN AND CONSTRUCTION STANDARDS. THE CONTRACTOR SHALL SUBMIT CERTIFIED DENSITY TESTS AS REQUIRED BY FPUA ENGINEERING AND THE CITY ENGINEERING DEPARTMENT, IN CASES WHERE PAVED AREAS FALL WITHIN THE JURISDICTION OF LOCAL OR STATE AGENCIES, THE COMPACTION REQUIRE- MENTS SHALL NOT BE LESS THEN THE MINIMUM REQUIRED BY THE APPROPRIATE RESPONSIBLE AGENCY. 5. A 1% MINIMUM SLOPE SHALL BE MAINTAINED ON ALL SANITARY SERVICE LATERALS. 6. THE CONTRACTOR SHALL FURNISH RECORD DRAWING INFORMATION TO THE ENGINEER CONSISTING OF PIPE SIZES, LOCATION OF SERVICE TEE WYES, DIAMETER OF SERVICES, LOCATION OF ANY FITTINGS, FINAL RIM AND INVERT ELEVATION OF ALL MANHOLES AND ANY OTHER PERTINENT INFORMATION NECESSARY TO LOCATE ITEMS CONSTRUCTED UNDER THIS PROJECT. 7. MAINTAIN SIX FEET AND PREFERABLY 10 FEET HORIZONTAL DISTANCE BETWEEN WATER MAINS AND SEWER MAINS AS A MINIMUM. 8. WASTEWATER FORCE MAINS, WASTEWATER COLLECTION LINES, AND STORM SEWERS SHOULD CROSS UNDER WATER MAINS WHENEVER POSSIBLE. A MINIMUM VERTICAL DISTANCE OF 12 INCHES BETWEEN THE INVERT OF THE UPPER PIPE AND THE CROWN OF THE LOWER PIPE SHALL BE PROVIDED WHENEVER POSSIBLE, WHERE THIS MINIMUM SEPARATION CANNOT BE MAINTAINED, THE CROSSING SHALL BE ARRANGED SO THAT THE WASTEWATER PIPE JOINTS AND THE WATER PIPE JOINTS ARE EQUIDISTANCE FROM THE POINT OF CROSSING, AND THE WATER MAIN SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE (DIP) AT THE CROSSING, SUFFICIENT LENGTHS OF DIP MUST BE USED TO PROVIDE A MINIMUM SEPARATION OF 10 FEET BETWEEN ANY TWO JOINTS. ALL JOINTS ON THE WATER MAIN WITHIN 20 FEET OF THE CROSSING MUST BE MECHANICALLY RESTRAINED. A MINIMUM VERTICAL CLEARANCE OF 6 INCHES MUST BE MAINTAINED AT ALL CROSSINGS, 9. A PRE- CONSTRUCTION CONFERENCE BETWEEN THE ENGINEER, THE CONTRACTOR, AND FPUA/CITY COUNTY/FDOT SHALL BE MANDATORY PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 10. NO FIELD CHANGES OR DEVIATIONS FORM THE DESIGN SHALL BE MADE WITHOUT PRIOR APPROVAL FPUA/CITY/COUNTY/FDOT ENGINEER, 11. TRAFFIC CONTROL, BARRICADES, ETC. SHALL BE IN ACCORDANCE WITH THE FLORIDA DEPARTMENT N STANDARDS. 12. CONTRACTOR SHALL NOTIFY FORT PIERCE UTILITIES AUTHORITY 48 HOURS PRIOR TO COMMMENCING CONSTRUCTION. 13. WASTEWATER FORCE MAIN SHALL BE POLYVINYL CHLORIDE CONFORMING TO AWWA C-900, AND SHALL BE CLASS 150, DR-18. 14. WASTEWATER FORCE MAIN SHALL BE GREEN IN COLOR OR WHITE IN COLOR. WASTEWATER FORCE MAIN SHALL HAVE THHN WIRE & LOCATOR TAPE WITH "SEWER" MARKED ON TAPE. OF THE PIPE. 15. FITTINGS SHALL BE CAST OR DUCTILE IRON, CONFORMING TO AWWA C-110 AND ANSI A21.11, CLASS 250 MINIMUM, INTERIOR POLYLINED, AND SEAL COATED, 16. WASTEWATER FORCE MAIN SHALL BE MARKED BY THE USE OF CONTINUOUS 10 GAUGE THHN WIRE (GREEN IN COLOR) PERMANENTLY ATTACHED TO THE TOP OF THE FORCE MAIN WITH LOCATOR TAPE MARKED "SEWER" ON TAPE IN ACCORDANCE WITH FPUA SPECIFICATIONS, 17. MINIMUM COVER SHALL BE 36 INCHES, PIPES WITH COVER LESS THAN 30 INCHES SHALL REQUIRE PRIOR APPROVAL OF THE UTILITIES ENGINEER AND SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE. 18. EACH SERVICE LATERAL WILL BE MARKED WITH A LOCATOR BALL AS MANUFACTURED BY 3M CORPORATION, OR APPROVED EQUAL AS REQUIRED BY FPUA ENGINEER, 19. ALL MANHOLES SHALL HAVE SEWER RAIN GUARDS INSTALLED AS REQUIRED BY FPUA ENGINEER. 20. THE CONTRACTOR SHALL COMPLY WITH THE FLORIDA TRENCH SAFETY ACT REQUIREMENTS. ATLANTIC CIVIL ENGINEERING, INC. CONSULTING ENGINEERS 2552 PETERS ROAD SUITE D FORT PIERCE, FLORIDA 34945 (772) 398-1520 PHONE (772) 398-1521 FAX CERTIFICATE OF AUTHORIZATION #32020 CALL 7OLL-FREE 1-800-452-4770 SUNSHINE STATE ONE CALL OF FLORIDA, INC UNDERGROUND UTILITIES NOTIFICATION CENTER DATE: 3/23/18 HORIZ SCALE: 1"=40' VERT SCALE: N/A - � M. JOB No. 2017-0109 SHEET 8 OF 8 C17 DATE