Loading...
HomeMy WebLinkAboutTRUSS 9-7-18Lumber des1gri-Value-s,are in accordance with ANSI/TPI 1 section 6.3 These truss�designs r6iy'oh lumber values established by others. MiTek SCANNED SY. Luc� le County RE: 74762 -WAREHOUSE MiTek USA, Inc. Site Information: 6904 Parke East Blvd. Tampa, FL 33610-4115 e WAREH Customer Info: DOYLE MASONRY Project Nam � Od pj= Lot/Block: Subdivision: F, 1�� Address: N/A F L-vt COPY City: ST LUCIE COUNTY State: Fl� Name Address and License # of Structural Engin er of Record, If there is one, for the building. Name: License #: Address: City: ". State: General Truss Engineering Criteria & Design L( Loading Conditions): Design Code: FBC2017[TP12014 Wind Code: ASCE 7-10 Roof Load: 37.0 psf This package includes 19 individual, dated Truss D With my seal aff ixed to this sheet, I hereby certify tl� conforms to 61 G 15-31.003, section 5 of the Florida (individual Truss Design Drawings Show Special a Program: MiTek 20/20 8.1 Speed: 170 mph Load: 55.0 psf n Drawings and 0 Additional Drawings. am the Truss Design Engineer and this index sheet trd of Professional Engineers Rules. No. I Seal# Truss Name I Date­N0___F_ . Seal# Truss Name I Date 11 1 T1 3947118 1 A 15/3/18 118 IT13947105 R 5/3/18 12 1 T1 3947119 1 Al 15/3/18 119, IT1394718,61KJ7 15/3/18 13 T139471201A2 15/3/18 —1 S S P DRA PPROVEI:) REVISE AND RES S SUBMITTAL WAS G GENERAL CONF 0 ONLY. THE CC C CONFIRMING AN Fo FOR TOLERANCE PROCESSES AN 0 coo 0 FU C FUL 13y By: 1 14- T139471211A3 15/3/18 15 1 T1 3947122 1 A4 15/3/18 16 IT13947123IA5 15/3/18 __J 17 IT13947124IA6 15/3/18--1 18 1 T1 3947125 1 A7 15/3/18 19 IT13947126IA8 15/3/18 110 1 T1 3947127 1 A9 15/3/18 Ill I T1 3947128 1 Al 0 15/3/18 112 IT13947129JAll 15/3/18 113 1 T1 3947130 1 FLA 15/3/18 114 1 T1 39471311 G RA 15/3/18 115 IT13947132IJ1 15/3/18 116 IT13947133IJ3 15/3/18 117 IT13947134IJ5 15/3/18 The truss drawing(s) referenced above have been prepared by� MiTek USA, Inc. under my direct supervision based on the parameters provided by Chambers Truss. Truss Design Engineer's Name: Velez, Joaquin My license renewal date for the state of Florida is February 28, 2019. IMPORTANT NOTE: The seal on these truss component designs is � certification that the engineer named is licensed in the jurisdiction(s) identified and that tl�e designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek's cust6mers file reference purpose only, and was not taken into account in the preparation�of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPl 1, Chapter 2. V., WING ITTAL REVIR 0 APPROVED AS NOTED UBMIT 0 REJECTED �EVIEWED FOR DESIGN CONFORMITYAND ORMANCE TO CONTf!�CT DOCUMENTS NTRACTOR IS RESPONSIBLE FOR COR )RRE CLFAp�aN�Rjl�t!�§IONS AT JOR.RIT= D TEI F HIS E TH Architectoni� Ini? -Ort Pierce, FL 34950 1111111" V41�4 fee e, 8182 / ir TE OF W N R �M1110 11111 -�06e6rt1686234 1, .Ivd. Tampa FL33610 Velez, Joaquin 1 of 1 Job Trus T'u S Truss Type aty Ply WAREHOUSE FA TI 3947118 74762 Common 20 Chambers Tuss inc Fwt Pie—;�—F[ Job Reference (optional) o. i 30 5 Mar i i 40 i a M, i ek i udush ieb, Iriu. i hu Mlay 3 12:15:49 20 18 Page i ID:IlhBm4QCiiHFiEguZxwhUPyGzMp-plfUvWzoupEzdl5DPybObmaDPJbMrqnDgw34ZRzKD u 4-10 30_8_0 50-11-6 61 4 9-9?;o 10-5-111 T _ 0_�.�O 9-9-10 0 Scale 1:101.8 4.00 FIT 5X8 1 32 5x6 7:;; 5x6 4x5 5 7 45 Zz� 6x8 4 8 7x8 WB-- 45 3 9 4x5 2 30 33 11 144 - IT 19 16 17 34 16 15 35 14 13 12 3x4 11 7x8 WB 4x4 4x8 4x4 7x8 WB= 3x4 11 4x8 4xB 7x10 11 7xlO 6x8 12- 104-10 0- �—�4 30-8-0 1 50-11-6 LO -4 _10 o.g 9_� E. o i 10-5-11 1 _.�4 0 14.0.10 9 0 -9-10 9 —1E Plate Offsets (X,Y)-- [1:0-2-6,Edgel,[3:0-4-0,Edqel,[9:0-4-0,Edqel,[11:0-2-6,EdgeI LOADING (psf) SPACING- 2-0-0 CS1 ' DEFL. in (loc) VdefI Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.88 Vert(LL) -0.38 15 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.94 Vert(CT) -0.7415-17 >993 240 BCLL 0.0 Rep Stress Incr YES WB 0.78 Horz(CT) 0.22 11 n/a n1a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(LL) 0.64 15 >999 240 Weight: 410 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x6 SP No.2 *Except* TOPCHORD Structural wood sheathing directly applied or 2-10-11 oc purlins. 1-3,9-11: 2x6 SP 240OF 2.OE BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT'CHORD 2x6 SP 240OF2.OE *Except* WEBS I Row at midpt 6-15,10-14,2-17 . 16-18:2x6SPNo.2 WEBS 2x4 SP No.3 &iJERS 2x4 SP'No.3 WEDGE Left: 2x4 SP-No.3, Right: 2x4 SP No.3 REACTIONS. (lb/size) 1=2269/0-8-0,11=2269/0-8-0 Max Horz 1 =-260(LC 10) Max Uplift 1=-1606(LC 12), ll=-1606(LC 12) FORCES. (lb) - May- Comp./Max. Ten. - All forces 250 (lb) or less except wihen show TOPCHORD 1-2=-5299/4033, 2-4=-4620/3618, 4-6=-348812890, 6-8=-3488/2890, 8-1 0=-4621/3618, 10-11�5301/4035 BOTCHORD 1-19=-363214939,17-19=-3632/4939,15-17=-3071/4317,14-15=-307 /4318, 12-14=-3634/4941, 11-12=-3634/4941 WEBS 6-15=-1162/1659,8-15=-1346/1144,8-14�168/597,10-14=-736/616, 0-12=01275, 4-15=-1344/1144, 4-17=-168/595, 2-17=-736/614,2-19=0/277 2 Rows at 1/3 pis 8-15,4-15 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. =3.Opsf; h=23ft; B=45ft; L=24ft; eave=7ft; Cat. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TC;DL=4.2psf; BCDL 11; Exp 0; Encl., GCpi=O.l 8; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, 1 1 pterior(l) 3-0-0 to 30-8-0, Exterior(2) 30-8-0 to 33-8-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 1 3) WARNING: This long span truss requires extreme care and experience lui pop, aniq Safe handling and erection. For general handling and erection guidance. see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses ("BCSI"), jointly produced by WTCA and TPI. For project specific guidance, c8 I nsult with project engineer/architecVgeneral contractor. MiTek assumes no responsibility for truss manufacture, handling, erection, or bracing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent With 'any other live' loads. 5) * This truss has been designed for a live load of 20.Opst on the bottom chord In all area's where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 1 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1606 lb uplift at joint 1 and 1606 lb uplift at joint 11. Joaquin Velez PE No.68182 MITek USA, Inc. 171. Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 3,2018 &WARNING - Vedlydesignpammeters and READ NOTES ON THIS AND INCLUDED MMEKREFERANCEPAIGEA111IL7473 rev. 10103V2016 BEFORE USE. Design valid for use only with MITek6 connectors. This design Is based only upon parameters shown. and Is for an Individual building componenL not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additioncil temporary and permanent bracing MeIC Is always required for stability and to prevent collapse with possible personal Injury and property dam6ge. For general guidance regarding the fabilcartlom storage, delivery, erection and bracing of trusses and truss systems. seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee SlreeL Suite 312, Alexandria, VA 2231 A. Tampa, FIL 33610 Job Truss Truss Type Qty Ply WAREHOUSE TI 3947119 74762 Al Hip 2 � Job Reference (optional) 4.00 F12 3 45 2 30 Eigil 19 18 17 4X8 3X4 11 4X4 7XIO 11 o. iou � ivim i i 4ujo ivii iuK muubmub, inu. i nu may a iz: jo:oj euin r-age i ID:IlhBm4QCiiHFiEguZxwhUPyGzMP-IhnFKB-2QQUgs2FcXNdUgBfep7HyJk2WBEYBdJzKD—s 30-0-0 4-P 41-9-8 -4 61-4-0 10-5-9 10-5-9 1 1-4-0 9-4- 10-1-12 Scale 1:105.5 5 6 31 32 7 7x8 WEI �4x5 7 9 6 33 34 16 15 14 35 13 12 11 4X4 = 4X4 3X4 4X4 10 4x8 7XIO 11 LOADING (psf) SPACING- 2-0-0 CS1. I DEFL. in (loc) Ydefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.57 Vert(LL) -0.35 17-19 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.94 Vert(CT) -0.69 15-17 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.80 Horz(CT) 0.22 10 n/a n1a BCDL 10.0 Code FBC2017ITP12014 Matrix -MS WInd(LL) 0.58 17-19 >999 240 Weight: 419 lb FT = 20% LUIMBER- BRACING- TQP CHORD 2x6 SP 240OF 2.OE *Except* TOPCHORD Structural wood sheathing directly applied or 3-10-1 oc purlins. 5-6:2x6 SP No.2 BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT&ORD 2x6 SP 240OF 2.OE *Except* WEBS I Row at midpt 2-17, 5-15, 6-14, 9-13 - 16-18: 2x6 SP No.2 2 Rows at 1/3 pts 4-15,7-14 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 WEDGE Left: 2x4 SP W.3, Right: 2x4 SP No.3 REACTIONS. (lb/size) 1=2269/0-8-0, 10=2269/0-8-0 Max Horz 1 =255(LC 11) Max Uplift 1=-1606(LC 12), 10=-1606(LC 12) FORCES. Qb) - Max. Comp.fMax. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-528714106, 2-4=-4665/3752, 4-5=-3541/3016, 5-6=-3276/2967, 6-7=-3541/3017, 7-9=-4666/3753, 9-10=-5289/4108 BOTCHORD 1-19=-3716/4927,17-19=-371614927,15-17=-3237/4380,14-15=-2251/3276, 13-14=-3226/4382, 11-13=-3706/4929, 10-11 =-3706/4929 WEBS 2-19=0/254, 2-17=-64a/543, 4-17=-1 43/580, 4-15=-1 364/1167, 5-15=-63I ' 3/822, 6-14=-638/810, 7-14=-1 371/1170, 7-13=-1 44/583, 9-13=-646/544, 9-11 =0/252 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4 . 2psf; BCDL 3.Opsf; h=23ft; B=45ft; L=24ft; eave=7ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Int6rior(l) 3-0-0 to 30-0-0, Exterior(2) 30-0-0 to 31-4-0, Interion(l) 35-6-15 to 61-4-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 Le 3) WARNING: This long span truss requires extreme care and experience for proper and handling and erection. For general handling and erection guidance, see Guide to Good Practice for Handling, Installing & B 'racing of Metal Plate Connected Wood Trusses ("BCSI"), jointly produced by WTCA and TPI. For project specific guidance, conisult with project engineer/architecitgeneral contractor. MiTek assumes no responsibility for truss manufacture, handling, erection, o bracing. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 6X8 MT20 unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 Wide Joaquin Velez PE No.68182 will fil between the bottom chord and any other members, with BCDL -= 10 Opsf I 8) Provide mechanical connection (by others) of truss to bearing plate capabie of �vlthstancli Ing 1606 lb uplift at joint 1 and 1606 lb uplift MiTek USA, Inc. Fl. Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 at joint 10. Date: May 3,2018 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFER—C. —F -11-74—ev. 1010312015 BEFORE USE. Design valid for use ortly with MffekO conneciors. INs design Is based only upon parameters shown, and Is for ar) Individual building component. riot a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord membeig only. Additional temporary and permanent bracing MiTelc Is always required for stability and to prevent collapse %-Alh possible personal Injury and properly damade. For general guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss systems. seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Bullcling Component Safety Information available from Iruss Plate Institute, 218 N. Lee Street. Suite 312, Alexandda, VA 22,314. 1 6904 Parke East Blvd. Tampa, FL 33610 Job . Truss Truss pe Qty Ply �,WAREHOUSE T1 74762 A2 Hip 2 lob Refere �Ijaflfllwws "Ubb, 111u., ruirL rieice, rL m3u s mar ii zuitj mijeKinaustries, inc. Thu May j 12:16:56 2018 I'age 1 ID: I [hBm4QCiiHFiEguZxwhUPyG7MP-6eaBNv2BEz6zyqBZJwDgNEMQy86lz5FHWGyl)(ZKD—n 21-0.0 334-0 61-4-0 5-- 50-29 1011 12 4-0 4 Z -9 1 j-4-5 5 1 AtU I g. - 1 10-4-5 Scale = 1:105.6 4'00 11-2 - 6x = 4.00 FIT 6x 6X8 6 ,0 3, 6 30 -316 7x8 WEI 6X8 - 2s 7x8 WEI 6X8 29 32 6X8 7x8 WEI 4 4 7 3 3X4 8 3X4 6 2 9 d 33 28 1 10 to 17 16 34 35 5 14 13 36 37 12 11 6X8 4X4 4X4 4x4 SX8 5X8 4X4 6X8 8X1 0 11 7X8 8XIO 11 5-442 -0 41 45-11-4 60-4-0 6140 4- 4-4-12 -0-0 I 0_0 I 12�_-�_�4 t 12-7-4 14-4-12 Plate Offsets (X,Y)-- [1:0-1-14,Edgel,[3:0-4-0,Edgel,[8:0-4-0,Edqel,[10:0-1-14,Edg'pI LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/cleff �Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.86 Vert(LL) -0.62 11-13 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.45 Verl(CT) -1.01 11-13 >732 240 BCLL 0.0 Rep Stress Incr YES WB 0.94 Horz(CT) 0.19 10 n/a nia BCDL 10.0 Code FBC2017/TP]2014 Matrix -MS Wind(LL) 0.64 11-13 >999 240 Weight: 397 lb FT = 20% LUMBER- BRACING- TQPCHORD 2x6 SP No.2 *Except* TOPCHORD Structural wood sheathing directly applied or 2-10-15 oc puffins. 1-3,8-10: 2x6 SP 240OF 2.OE BOTCHORD Rigid ceiling directly applied or 5-2-12 oc bracing. BOT6HORD 2X6 SP 240OF 2.OE WEBS I Row at midpt 4-15.7-13 WEBS - 2x4 SP No.3 OZ;HERS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (lb/size) 1=2269/0-8-0, 10=2269/0-8-0 Max Harz 1 =-238(LC 10) Max Uplift 1 =-1 606(LO 12), 1 0=-1 606(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-5300/4276, 2-4=-4992/3971, 4-5=-3859/3263, 5-6=-3608/3184, 6- =-3859/3263, 7-9�4992/39711 9-10=-5300/4276 11 BOTCHORD 1-17=-3891/4938,15-17=-3352/4419,13-15=-2514/3595 11-13=-3341 1.419, 10-11=-3880/4938 WEBS 2-17=-411/556, 4-17=-1 95/656, 4-15=-1 189/1037, 5-15=-573/909, 6-13= 573/909, 7-13=-1189/1037,7-11=-195/656,9-11=-411/556 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132niph; TCDL=4.2psf; BCDL=3.Opsf; h=23ft; B--45ft; L=24ft; eave=7ft; Cat. 11; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interlor(l) 3-0-0 to 28-0-0, Exterior(2) 28-0-0 to 37-6-15, Interfor(l) 37-6-15 to 61-4-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) WARNING: This long span truss requires extreme care and experience for proper and slafe handling and erection. For general handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses (uBCSI"), jointly produced by WTCA and TPI. For project specific guidance, cogsult with project engineer/architect/general contractor. MiTek assumes no responsibility for truss manufacture, handling, erecti,on, or bracing. 4) Provide adequate drainage to prevent water ponding. i 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with a nly other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas1where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf. 1 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1606 lb uplift at joint 1 and 1606 lb uplift Joaquin Velez PE No.68182 at joilit 10. MiTek USA, Inc. FL Cott 8834 6904 Parke East Blvd. Tampa Fl. 33610 Date: May 3,2018 &WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED mrrEKREFERAmcE PAGE M11-7473 rev. 10103J2015 BEFORE USE Design valid for use only with Mffek(D connectors. This design Is based only upon parameters shown, and is for an individual building component, not bit a truss system. Before use. the bullding designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord membe4 only. Additional temporary and permanent bracing WOW Is always required for stability and to prevent collapse with possible personal Injury and property darn For general guidance regarding the fabricatiom storage, dellvery� erection and bracing of trusses and truss systems, seeANSI/TPI I Quality C-ld Lo, IDSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria. VA 22314. Tampa, FL 33610 Job Truss Truss - pe Qty Ply WAREHOUSE T1 3947121 74762 A3 Hip 2 � Job Reference (optional) am als ss' ric., OIL larce, 8J30 s Mar i i 20i8 MiTek indusiries, inc. Thu May 3 i2:15:57 20its Page i ID:IlhBm4QCiiHFiEguZxwhUF'yGzMP-ar8WaF3p?GEqazjmtekvwRvcaYSEjUDPWA?VrzzKD m 9-6-8 IL-Z 6 35-4-0 -8-10 1 �1 -4-,0 A 9-6-8 _0_; 18 % —102 9-4-0 1-�.1-08- - 4 Scale 1:105.6 4. 00 F1 _2 6x12 6x8 5 3031 6 6x8 i:� 45 5-� 29 32 4x5 zzz 6x8 X8 45 29 32 3 4 7 8 N 3x4 3X4 /I 2 9 c� 33 a) 28 10 '7 IT o 17 16 34 15 14 35 13 36 112 it 7x8 WB= 4X4 5x6 4x8 7x8 4x4 48 48 4x4 8x10 11 Bx10 11 2- 26-0-0 T2 35-4-)g 48-1-7 60-4-0 6 -4 1 0- _9 1-n- JEN i2- 12-9-8 12-9-8 12-2-9 Plate Offsets (X,Y)-- J1:0-1 -10, Edgel, [3:0-4-0, Edge], [8:0-4-0, Edgel, It 0:0-1 -10, Edgbl LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) *Vdefl Ud PLATES GRIP TOLL 20.0 Plate Grip DOL 1.25 TO 0.81 Vert(LL) -0.46 11-13 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.43 Verl(CT) -0.87 15-17 >844 240 66LL 0.0 Rep Stress Incr YES WB 0.69 Horz(CT) 0.19 10 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS WInd(LL) 0.63 15-17 >999 240 Weight: 405 lb FT = 20% LUMBER- BRACING- TGPCHORD 2x6 SP No.2 *Except* TOPCHORD Structural wood sheathing directly applied or 2-8-8 oc puriins. 1 '3110: 2X6 SP 240OF 2.OE BOTCHORD Rigid ceiling directly applied or 5-1-13 oc bracing. BOT&ORD 2x6 SP 240OF 2.OE WEBS 1 Row at midpt 4-15, 5-13, 7-13 WEBS 2x4 SP No.3 *Except* 5-13: 2X4 SP M 30 OTHERS 2x4 SP No.3 WEDGE Left: 2x4 SP Wo.3, Right: 2x4 SP No.3 REACTIONS. (lb/size) 1=226910-8-0, 10=2269/0-8-0 Max Horz 1 =-221 (LC 10) Max Uplift 1=-1606(LC 12), 10=-1606(LC 12) FORCES. Qb) -Max. Comp./Max. Ten. -.All forces 250 (lb) or less except when shown.. TOPCHORD 1-2=-5319/4304, 2-4=-507714101, 4-5=-4031/3440, 5-6=-3748/3378, 6-7=-3999/3440, 7-9=-5049/4101, 9-10=-5318/4304 BOTCHORD 1-1 7=-3925/4953,15-17=-3503/4485,13-15=-2755/3767,11-13=-34921��4459, 10- 11 =-3913/4953 WEBS 2-17=-314/439, 4-17=-183/594, 4-15=-962/920, 5-15=-474/910, 5-13=-316/318, 6-13=-490/862, 7-13=-961/920, 7-1 1=-183/593, 9-1 1=-314/439 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=l 70mph (3-second gust) Vasc1=1 32mph; TCDL=4.2pst; BCDL_3.0psf; h=23ft; B=45ft; L=24ft; eave=7ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterlor(2) 0-0-0 to 3-0-0, Inierior(l) 3-0-0 to 26-0-0, Exterior(2) 26-0-0 to 39-6-15, Interior(l) 39-6-15 to 61-4-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 1 3) WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general handling and erection guidance, see Guide to Good Practice for Handling, Installing & Blacing of Metal Plate Connected Wood Trusses ('BCSI'), jointly produced by WTCA and TPI. For project specific guidance, consult with project engineer/architect/general contractor. MiTek assumes no responsibility for truss manufacture, handling, erection, or I bracing. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonco[ I— I., it with .1 "veloads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = I O.Opsf. Joaquin Velez PE No.68182 7) ProvWe mechanical connection (by others) of truss to bearing plate capable of withstanding 1606 lb uplift at joint 1 and 1606 lb uplift MiTek USA, Inc. FL Cart 8834 at joint 10. 6904 Parke East Blvd. Tampa FL 33610 Date: May 3,2018 & WARNING- llerWdesfan parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCEPAGIEM11-7473 rev. 10103)2016 BEFORE USE. Design valid for use only wIth Mffek@) connectors. This design Is based only upon parameters shown. and Is for an Individual building component, not a truss system. Before use. the building designer must verify the app4icability of design parameters and r5roperly Incorporate this design Into the overall building design. Bracing Indicaled Is to prevent buckling of Individual lam web and/or chord membeni only. Addillonal temporary and permanent bracing MiTeW Is always required for stability and to prevent collapse with possible personal Injury and property damade. For general guidance regarding the fabricatiom storage, delivery, erection and bracing of trusses and truss system% seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute. 218 N. Lee StreeL Suite 312, Mexandft VA 22314. 1 6904 Parke East Blvd. Tampa, FL 33610 Job Truss Truss Type city Ply WAREHOUSE TI 3947122 74762 A4 Hip 2 Job Refere n—, FUI L MVI UU, rL tmou s mar ii ZUItS P111 IeK mausTnes, Inc. inu may ;j 1znb:btj zuitj Fage i IDA IhBm4QCiiHFiEguZxwhUPyGzMP-21 iuob4RmaMhC7HyRLF8SfRnuxeeSxCYlql3NPzKD—I 37-4-0 14-10-12 L2 3�5 61(� ;0 6-8-0 7-6-1 T 4.00F1_2 6x8 3x4 11 6x8 4x5 -- 5 32 6 33 7 6x8 31 4 3 3x4 2 30 1 19 1836 37 17 38 16 15 39 14 4x4 7xB 4X4 4x8 4x4 4x8 5x6 8xio 11 I LOADING (psi) SPACING- 2-0-0 CSL TCLL 20.0 Plate Grip DOL 1.25 TC 0.77 TCDL 7.0 Lumber DOL 1.25 BC 1.00 Br,LL Rep Stress Incr YES WB 0.64 BCDL 1 Code FBC2017fTP12014 Matrix -MS LUMBER- TQP CHORD 2x6 SP No.2 *Except* 1-3,9-11: 2x6 SP 240OF 2.OE BOT6HORD 2x6SP240OF2.OE *Except* , 16-18:2x6SPNo.2 \/V_EBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (lb/size) 1=2269/0-8-0,11=2269/0-8-0 Max Harz 1 =204 (LC 11) Max Uplift 1=-1606(LO 12), ll=-1606(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-5302/4343, 2-4=-5032/4146, 4-5=-4162/3618, 5-6=-4079/3690, 6. 7-8=-4163/3618, 8-1 0=-5027/4146, 10-11 =-5298/4342 BOTCHORD 1-1 9=-3963/4936, 17-19=-3624/4565, 15-17=-2957/3895, 14-15=-294E 12-14=-3613/4564, 11-12=-3950/4933 WEBS 2-19=-267/386, 4-19=-108/491, 4-17=-877/831, 5-17=-462/808, 5-15=- 6-15=-396/494, 7-15=-325/538, 7-14=-463/810, 8-14=-874/832, 8-12=- 10-12=-268/385 45 zz� 34 6X8 zz� 8 3X4 -5�, 110 0 fft - 40 13 41 12 7x8 = 4x4 48-1-11 1 60-4 DEFL. in (loc) Vdefl Ud Vert(LL) -0.41 17-19 >999 360 Vert(CT) -0.79 17-19 >937 240 Horz(CT) 0.21 11 n/a IVA Wind(LL) 0.65 15 >999 240 BRACING- Scale = 1:105.7 35 4xB 8X10 11 PLATES GRIP MT20 244/190 Weight: 419 lb FT = 20% TOPCHORD Structural wood sheathing directly applied or 3-1-9 oc purlins. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 4-17,8-14 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDJ3.0psf; h=23ft; B=45ft; L=24ft; eave=7ft; Cat. 11; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Exterlor(2) 0-0-0 to 3-0-0, inierior(l) 3-0-0 to 24-0-0, Exterior(2) 24-0-0 to 41-6-15, Interlor(l) 41-6-15 to 61-4-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) WARNING: This long span truss requires extreme care and experience for proper and �safe handling and erection. For general handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses ("BCSI"), jointly produced by WTCA and TPI. For project specific guidance, con' suit with project engineer/architecttgeneral contractor. MiTek assumes no responsibility for truss manufacture, handling, erection, o1r bracing. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with a�ny other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas�where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, With BCDL = 10.0psf. 1 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1606 lb uplift at joint 1 and 1606 lb uplift at joint 11. 1 I— Joa4uin Velez PE No.68182 MiTek USA, Inc. FL Cart 8834 6904 Parke East Blvd. Tampa FL 33610 Date: May 21,2018 & WARNING. Verify daslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK R.—A.— — E —1-7473 rev. 10/03,2015 BEFORE USE. Design valid for use only with MITek@) connectors. This design Is based only upon parameters shown. an!c! Is for an Individual building component, not a truss system. Before use. the bulicring designer must verify the applicability of design parameters and property incorporate this design Into the overall design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTeW building prevent Is always required for stability and to prevent collapse with possible personal Injury and property clamq�e. For general guidance regarding the fabricallon, storage, delivery, erection and bracing of fusses and truss system% seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss plate Institute. 218 N. Lee StreeL Suite 312, Mexandda, VA 22314.1 6904 Parke East Blvd. Tampa, FL 33610 Job Truss Truss pe WAREHOUSE �Q T11 3947123 74762 A5 Hip 2 1 iiam.G.s 'iuss' rierce, rL 8. 130 s iviar i i 2018 MiT ek i ndusiries, inc. Thu May 3 i 2: i 6:01 2018 Page i I D: 1 IhBm4QCiiHFi EguZxwh UPyGzM P-ScN I Qc6J3VIG3bOX6Upr4H31ugiAfKn—Rozj—kzKDj 60 - 50 30-8-0 1 39-4-0 4%-32 1 61-4-0 13-1-13 8-8-0 8-8-0 8_ 0_ 13-1-14 Scale = 1:105.5 4.00F1_2 3X4 11 6X8 7x8 WB= 6X8 4X5 ::r 4 31 32 56 33 347 4X5 �Zz 6x8 5:- 30 35 8 Z�- 36 29 I 10 7 '5� EM ? 18 17 16 37 15 14 38 13 12 11 3X4 11 6x8 4X4 48 4X4 6x8 3X4 5X8 5X8 7XIO 11 7x10 5X6 14-11-1132 30-8-0 39-4-0 18 �0 - 60-4- 0 61-40 1E2o_9 E;20--3 3� 12-1-14 11-0-0 Plate Offsets (X.Y)-- [1:0-2-2,Edgel, [3:0-4-0,Edgel, f4:0-5-8,0-3-121, [6:0-4-0,Edqel,1[7:0-5-8,0-3-121, [8:0-4-0,Edgel, [10:0-1-14,Edgel LOADING (psf) SPACING- 2-0-0 CS11. DEFL. in (loc) Vdefl Ud PLATES GRIP TOLL - 20.0 Plate Grip DOL 1.25 TO 0.79 Vert(LL) -0.41 14 >999 360 MT20 244/190 TGDL 7.0 Lumber DOL 1.25 BC 0.88 Vert(CT) -0.76 14-16 >973 240 BOLL 0.0 Rep Stress Incr YES WB 0.52 Horz(CT) 0.21 10 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(LL) 0.67 14 >999 240 Weight: 400 lb FT = 20% LUMBER- TOPCHORD 2x6 SP No.2 *Except* 1-3,8-10: 2x6 SP 240OF 2.OE BOTCHORD, 2x6 SP 240OF 2.OE *Except* 15-17: 2x6 SP No.2 Wll�BS 2x4 SP No.3 OTH�RS 2x4 SP No.3 WEDGE Left: 2x4 SP NoA Right: 2x4 SP No.3 REACTIONS. (lb/size) 1=2269/0-8-0, 10=2269/0-6-0 Max Harz 1 =-1 87(LC 10) Max Uplift I =-I 606(LC 12), 1 0=-1 606(LC 12) FORCES. (lb) -Max. Comp./Ma)L Ten. -All forces 250 (lb) or less except when show TOPCHORD 1-2=-5234/4308, 2-4=-4372/3787, 4-5=-4465/4015, 5-7=-4465/4015, 9-10=-5233/4309 BOTCHORD 1-18=-3903/4865,16-18=-3903/4865,14-16=-3176/4081,13-14=-31I 11 -1 3=-3893/4865, 10-11 =-3893/4865 WEBS 2-18=0/361, 2-16=-920/818, 4-16=-346/64214-14=-486/74815-14=-5: 7-14=-4851748, 7-13=-347/643, 9-13=-920/819, 9-11 =0/358 BRACING- TOPCHORD Structural wood sheathing directly applied or 3-0-4 oc purlins. BOTCHORD Rigid ceiling directly applied or 3-8-6 oc bracing. WEBS 1 Row at midpt 2-16,4-14, 7-14,9-13 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=1 70mph (3-second gust) Vasd=1 32mph; TO: DL=4.2psf; BCDLj3.Opsf; h=23ft; B=45ft; L=24ft; eave=7ft; Cat. 11; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(l) 3-0-0 to 22-0-0,'Exterior(2) 22-0-0 to 43-6-15, Interior(l) 43-6-15 to 61-4-0 zone; cantilever left and right exposed ;C-C for me�bers and forces & MWFRS for reactions. shown; Lumber DOL=1.60 plate grip DOL=1.60 3) WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general handling and erection guidance, see Guide to Good Praclice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses ("BCSI"), jointly produced by WTCA and TPI. For project specific guidance, consult with project engineer/architect/general contractor. MITek assumes no responsibility for truss manufacture, handling, erection, or� bracing. 4) Provide adequate drainage to prevent water ponding. i 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas �here a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL == 10.Opsf. - 7) Provrde mechanical connection (by others) of truss to bearing plate capable of withstanding 1606 lb uplift at joint 1 and 1606 lb uplift at joint 10. . I Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 69D4 Parke East Blvd. Tampa I'L 33610 Date: May 3,2018 J i &WARMING -Varily designparamelers and READ NOTES ON THIS AND INCLUDED MITEKREFERANCEPAG I E 11111-7473 rev. 10/03,2015 BEFORE USE. Design valid for use only with MITek8 connectors. TNs design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use. the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall buildingdesign. Brdclng Indicated Is to prevent buckling of Individual truss web aridlor chord member�,onty. Additional temporary and permanent bracing WeIC Is always required for stability and to prevent collapse wilh possible personal Injury and property damag, e. For general guidance regarding the fabrIcation. storage. delivery. erection and bracing of trusses and truss systems. seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke liast Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street Sulte 312, Aexandda. VA 22314. 1 Tampa, FIL 33610 Job ' Truss Truss pe 9ty Ply WAREHOUSE TI 3947124 74762 A6 HIP 2 1� Job Refere '5."Ju s rviar ii xvits iviiieK inausures, inc. inu iviay j iz:­rb:uz zuits vage i ID: I ]hBm4QCii HFj EguZxwhUPyGzM P-xoxPdy7yqpt7hibigBK4dVcR6ZBI OmoBgSjGWAzKD—h 41-4-0 51-2-4 61-4-0 W 4.00FI-2 7X8 � 3X6 6X8 ?X8 4 31 32 5 33 34 7 6X8 -6 6X8 30 35 45 5ax" 3 8 4X5 2 > C� 29 18 17 16 37 15 14 38 13 12 4X8 3X4 11 6x8 4X4 4X8 4X4 6X8 3X4 7x10 5x6 = 20-0-0 41-4-0 0-4 Scale = 1: 105.4 4X8 7x10 11 60-4-0 61-4�O C� 36 10 6 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.95 Vert(LL) -0.40 14 >999 360 MT20 244/190 TODL 7.0 Lumber DOL 1.25 BC 0.50 Vert(CT) -0.74 14-16 >992 240 BCLL 0.0 Rep Stress Incr YES WB 0.54 Horz(CT) 0.20 10 n/a rda BCDL 10.0 Code FBC2017/TP]2014 Matrix -MS Wind(LL) , 0.67 14 >999 240 Weight: 398 lb FT = 20% LUMBER- TC)P CHORD 2x6 SP 240OF 2.OE *Except* 6-7.,2x6 SP No.2 BOT CHORD. 2x6 SP 240OF 2.OE WEBS 2x4 SP No.3 VOIEDGE Left: �x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (lb/size) 1=2269/0-8-0, 10=2269/0-8-0 Max Harz 1 =-1 70(LC 10) Max Uplift I =-1 606(LC 12), 1 0=-1 606(LC 12) BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 5-0-1 oc bracing. WEBS 1 Row at midpt 2-16, 4-14, 7-14, 9-13 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. I TOPCHORD 1-2=-5314/4411, 2-4=-4608/3955, 4-5=-4947/4418, 5-7=-4947/4418, 7-9=-46( 9-10=-5314/4411 BOTCHORD. 1 -1 8=-4036/4957,16-18=-4036/4957, 14-16=-3401/4305, 13-14=-3387)4304, 11-13=-4025/495B, 10-11=-4025/4958 1 WEBS 2-18=0/264, 2-16=-7381676, 4-16=-205/616, 4-14=-710/1013, 5-14=-648/807, 7-14=-711/1011, 7-13=-206/617, 9-13=-738/678, 9-11 =0/264 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. Opsf; h=23ft; B--45ft; L=24ft; eave=7ft; Cat, 2) Wind: ASCE 7-10; VUlt=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, lnl�erior(l) 3-0-0 to 20-0-0, Exterior(2) 20-0-0 to 45-6-15, Interlor(l) 45-6-15 to 61-4-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) WARNING: This long span truss requires extreme care and experience for proper and lafe handling and erection. For general handling and erection guidance, see Guide to Good Practice for Handling, Installing & Blracing of Metal Plate Connected Wood Trusses CBCSi'), jointly produced by WTCA and TPI. For project specific guidance, consult with project engineertarchitect(general contractor. MITek assumes no responsibility for truss manufacture, handling, erection, or' bracing. 4) Provide adequate drainage to prevent water ponding. 1 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent With a n,y other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL:= 1 0.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstandi ; Fig 1606 lb uplift at joint 1 and 1606 lb uplift at joint 10. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Carl 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: May 3,2018 ,&WARNING -Vefify dest4n pararrreters and READ NOTES ON THIS AND INCLUDED MIIIEKREFERANCE PAGE M11-7473 rev. 101030715 BEFORE USE Design valid for use ody with MITeM connectors. INs design Is based only upon parameters shown. an� Is for an Individual building component, not 0 truss system. Before use. the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall buildingdesIgn. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication. storage, delivery. erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria. DSEI-89 and SCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 1 6904 Parke East BWd. Tampa, FL 33610 Job Truss Truss Type Qty Ply WAREHOUSE TI 3947125 74762 A7 HIP 2 Job Reference (optional) L;naMDerS Lru5s, inc., rU[L rietue, rL 10-1-13 1 ID:l]hBm4QCiiHFiEguZxwhUPyGzMP-P?Vnri8ab6?_]uAvDurJgigdXyNJ7EjHu6Sq2dzKD�-c 4-1%1 14 4 i 51-2-3 61-4-0 8_ 7-10-3 5 10 Scale= 1: 105.5 4.00 F1_2 3x4 I 7xB 6*8 4x4 M 4 33 34 5 35 36 8 M - M 32 32 37 3 2 10 17 a 6 20 Is 18 39 17= �16 40 15 41 14 13 12 6x8 3X4 11 1 6X8 4x8 7x8 4x4 4x4 3x4 11 5X8 7x10 II 4x4 6X8 7x10 11 II-0-g 01-11,3 -0 65-1155 1_ '8 34-10-1 0 51-2-3 0�4 0 _ _5 61-40 1_ _ _ — - 8 -4-3 i a _g 7-10-3 -0-0 Plate Offsets (X,Y)-- [1:0-2-2,Edgel, [3:0-2-8,0-4-81, [3:0-0-0,0-2-121, [4:0-5-4,0-4-41, [6:0-4-0, Edge], 5— [8:0-5-4,0-4-41, [9:0-2-4, 4-81,19:0-0-0,0-2-121, fl 1 :0-2-2, Edge] LOADING (Psf) SPACING- 2-0-0 CS11. DEFL. In (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.84 Vert(LL) -0.51 15-17 >999 360 MT20 244/190 TGDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -0.95 15-17 >774 240 BCLL 0.0 Rep Stress Incr YES WB 0.50 Horz(CT) 0.22 11 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(LL) 0.85 15-17 >864 240 Weight: 405 lb FT = 20% LUMBER- BRACING - TOP CHORD 2X6 SP No.2 *Except* EOP CHORD Structural wood sheathing directly applied or 2-8-6 oc puffins. 1-3,9-11: 2x6 SP 240OF 2.OE BOTCHORD Rigid ceiling directly applied or 3-6-9 oc bracing. BOT CHORD, 2x6 SP 240OF 2.OE *Except* WEBS 1 Row at midpt 2-18, 4-17, 7-17, 8-15,10-14 16-19: 2x6 SP No.2 WtBS 2x4 SP No.3 WEDt!E Left: 2x4 SP'No.3, Right: 2x4 SP No.3 REACTIONS. (lb/size) 1=2269/0-8-0,11=2269/0-8�O Max Horz 1 =-1 53(LC 10) Max Uplift 1 =-1 606(LC 12), 11 =-1 606(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-5283/4430,2-4=-4754/4119, 4-5=-5331/4727, 5-7=-5331/4727, 7-8=-5332/4729, 8-1 0=-4757/4122, 10-11 =-5284/4431 BOTCHORD 1-20=-4050/4926,18-20=-4050/4926,17-18=-3579/4459,15-17=-4276/5332, 14-15=-3570/4462, 12-14=-4039/4926, 11-12=-4039/4926 WEBS 2-1 8=-561/517, 4-18=-205/511, 4-17=-953/1255, 5-17=-476/604, 7-1 5=-574/616, 8-15=-952/1252, 8-14�208/514,10-14=-559/516 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=l 70mph (3-second gust) Vasd=132mph; TCDL--4.2psf; BCDL=3.Opsf; �=23ft; B=45ft; L=24ft; eave=7ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(l) 3-0-0 to 18-0-0, Exterior(2) 18-0-0 to 47-6-15, Interfor(l) 47-6-15 to 61-4-0 zone; cantilever left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) WARNING: This long span truss requires extreme care and experience for proper and safe han�dllng and erection. For general handling and erection guidance, see Guide to Good Practice for Handling, Installing & BraclnR,,of I Met I Plate Connected Wood 'st u Trusses ("BCSI"), jointly produced by WTCA and TPI. For project specific guidance, con 'it. h .J:ct engineer/architect/general contractor. MITek assumes no responsibility for truss manufacture, handling, erection, or bracing..� 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1606 lb uplift at joint 1 and 1606 lb uplift at joi6t 11. Joaquin Velez PE No.68182 MiTek USA, Inc. Fl. Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: May 3,2018 &WARNING -Verify design p.rameters and READ NOTES ON THIS AND INCLUDED MrTEK REFERANCE PAGEMII-7473 re I Y. 10/03,2015 BEFORE USE Design valid for use only with MiTekO connectors. This design Is based only upon parameters shown, and Is for an Individual building component. not a truss system. Before use, the building designer must verIfy the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M!Tek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For geneial guidance regarding the fabilcation, storage. delivery, erection and bracing of trusses and truss systems, se.eANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informallon available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job . Truss Truss Type Qty PI WAREHOUSE TI 3947126 74762 A8 HIP 2 Job i unamoers Lruss, inc., 10-1-13 29 0 rUIL riuiue, rL 4.00F1_2 6xlOMT18HS= 4X5 4 6X8 2 3 is 17 37 5X8 3X4 7X8 7XIO ID:l]hBm4QCiiHFiEguZxwh6PYG���L!��;�'—'�Z;��h"Y'Ci�ILJi�� 1 51-2-3 9-9-15 LT �, -3, AMS 5-10-3 3X4 11 7X8 WEI = 4x4 = WO MT18HS — 31 32 5 -6 7 33 34 8 4x6 Z�- 6X8 9 10 16-0-0 25-9-15 16 is 38 14 39 13 12 '10 = 4X4 7x8 3X4 5x8 MIT18HS = Scale = 1:105.5 5X8 7x10 11 36 11 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Vdefl Ud PLATES GRIP TOLL 20.0 Plate Grip DOL 1.25 TO 0.67 Vert(LL) -0.51 14-16 >999 360 MT20 244/190 TQDL 7.0 Lumber DOL 1.25 BC 0.47 Vert(CT) -0.96 14-16 >765 240 MT18HS 244/190 BOLL 0.0 Rep Stress Incr YES WEI 0.80 Horz(CT) 0.21 11 n/a n/a BCDL 10.0 Code FBC2017fTP[2014 Matrix -MS Wind(LL) 0.85 14-16 >861 240 Weight: 400 lb FT = 20% LUMBER- ' BRACING- TOPCHORD 2x6 SP 240OF 2.OE *Except* TIOP CHORD 2-4,8-10: 2x6 SP No.2 BOTCHORD BOT CHORD. 2X6 SP 240OF 2.OE WEBS WEBS 2x4 SP No.3 01�HERS 2x4 SP No.3 WEDZ3E Left: 2x4 SP Ko.3, Right: 2x4 SP No.3 REACTIONS. (lb/size) 1=2269/0-8-0, 11=2269/0-8-0 Max Horz 1 =1 36(LC 11) Max Uplift 1 =-1 606(LC 12), 11 =-1 606(LO 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-5242/4437, 3-4=-4918/4292, 4-5=-5978/5258, 5-7=-5978/5258, 7-8=-5980/5262, 8-9=-4918/4291, 9-11 =-5242/4437 BOTCHORD 1-1 8=-4049/4882, 17-18=-4049/4882, 16-17=-3767/4636, 14--16=-4855/5980, 13-14m-3754/4636, 12-13=-4037/4883, 11-12=-4037/4883 WEBS 3-17=-342/327, 4-17=-1 84/471, 4-16=-1 33211693, 5-16=-552f7O4, 7-14=-6271712, 8-14=-1337/1696, 8-13�183/471, 9-13=-343/328 Structural wood sheathing directly applied or 3-0-9 oc purlins. Rigid ceiling directly applied or 4-8-12 oc bracing. 1 Row at midpt 4-16, 7-16,8-14 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=1 70mph (3-second gust) Vasd=1 32mph; TCDL--4.2psf; BCDL=3.Opsf; n I =23ft; B--45ft; L=24ft; eave=7ft; Cat. 11; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interlor(l) 3,-0-0 to 16-0-0, Exterior(2) 16-0-0 to 49-6-15, Intedor(l) 49-6-15 to 61-4-0 zone; cantilever left and right exposed ;C-C for members a d forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 `1 3) WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses ("BCSI'), jointly produced by WTCA and TPI. For project specific guidance, consult with �roject engineer/architect/general contractor. MiTek assumes no responsibility for truss manufacture, handling, erection, or bracing. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent With any other liv.� loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide . will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf. 1 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1606 lb uplift at joint 1 and 1606 lb uplift at joint 11. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 8834 6904 Parke East Blvd. Tampa FL 33610 Date: May 3,2018 WARNING- V.1ifydesIgnparaM.N. dRE4D NOTES ON THISAND INCLUDED MITEK REFERANCE PAGE M11-7473 rvv.�10103)2016 BEFORE USE Design valid for use onlywith Mflek(g) conneciors. This design Is based only upon parameters shown, and Is for an Individual building component riot a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this desIgn Into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additio6al temporary and permanent bracing MOW is always required for stability and to prevent collapse wilh possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss systems, seeANsi/Tpi i Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information avollable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria. VA 22314. Tampa, FL 33610 Job pe aty Ply WAREHOUSE T1 3947127 74762 A9 Hip 2 Job Reference (optional) unamoers iruss, inc., r-011 MerGIR, rL 7-7- 4-0-0 22-4-1 16-4-2 8-4-1, _1 4 6xl 0 MTi 8HS 4.00F1_2 3 34 35 1Z 0 0. IOU 0 IVIal I I — 10 IVII I URI I I ". .—Y � — I-- ­. , b'� , ID:llhBrrf4QCiiHFiEguZxwhUPyGzMP-paBwTKASulNYgMvUvIOOnLn7lAVDKWFka4hUfyZKD — d 3�-11�72 710 *3 s �2 8_3 1 % _� L __ '_ _j 1 U 4x4 = 5xS MTISHS 3x4 11 4 36 7��6 5x8 IVITI 8HS = 4x4 — — 7 837 38 6xl 0 MT1 8HS = 39 9 4X5 �� 33 2 33 10 32 21 4x10 3x4 11 6XIO 11 20 19 18 1 16 15 14 13 12 6XB 4X6 4X8 4x5 4X4 3x4 11 4X4 .5X8 MTJ�BHS 6x8 I 0-g 7-77-14 1400 22-4-14 8 0 6_� 8-4-14 %0 11 2 8 Plate Offsets (X,Y)-- fl:0-0-8,1-7-121, [1:0-1-10,Edgel, [3:0-5-8,0-3-01,[9:0-5-8,0-3-01, I'llio-1-10,Edgel, f11:0-0-8,1-7-121 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. In (loc) Vdefl Ud TOLL 20.0 Plate Grip DOL 1.25 TO 0.89 Vert(LL) -0.66 16 >999 360 TGDL 7.0 Lumber DOL 1.25 BC 0.50 Verl(CT) -1.22 16 >605 240 BOLL 0.0 Rep Stress Incr YES WEI 0.83 Horz(CT) 0.22 11 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Wind(LL) 1.10 16 >666 240 LUMBER- IiRACING- TOP CHORD 2x6 SP No.2 *Except* YOPCHORD 3-5,7-9: 2X6 SP 240OF 2.OE B6,TCHORD E30T CHORD. 2x6 SP 240OF 2.011 W BS WEBS 2X4 SP No.3 MEDGE Left: �x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (lb/size) 1=2269/0-8-0,11=2269/0-8-0 Max Horz 1 =1 19(LC 11) Max Uplift 1 =-1 606(LC 12), 11 =-1 606(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-5172/4411, 2-3=-5084/4418, 3-4=-6436/5643, 4-6=-6955/6049, 6-8=-6955/6049, 8-9=-643615643, 9-1 0=-5084/441 8, 10-11 =-5172/4411 BOTCHORD 1-21 =-4054/4828, 20-21 =-4054/4828,18-20=-3943/4800,16-18=-5293/6436, 15-16=-5281/6436, 13-15=-393114800, 12-13=-4042/4828,11-12=-4042/4828 WEBS 2-21=-146/263, 2-20=-129/282, 3-20=-84/377, 3-18=-1624/2008, 4-18=-833/862 4-16=494f707, 6-16=-427/526, 8-16=-4941707, 8-15=-833/862, 9-15=-1624/200 ii, 9-13=-84/377,10-13=-129/282,10-12=-146/263 Scale = 1:104.5 4xiO 6XIO 11 PLATES GRIP MT20 244/190 MT18HS 244/190 41 6 Weight: 405 lb FT = 20% Structural wood sheathing directly applied or 2-5-6 oc purlins. Rigid ' ceiling directly applied or 4-6-5 oc bracing. 1 Row at midpt 3-18.9-15 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=1 70mph (3-second gust) Vasd=1 32mph; TCDL=4.2psf; BCDL=3.0psI; I i=23ft; B=45ft; L=24ft; eave=7ft; Cat. 11; Exp C; Encl., GCpl=O. 18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(l) 3-0�O to 14-0-0, Exterlor(2) 14-0-0 to 51-6-15, Interlor(l) 51-6-15 to 61-4-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses ("BCSI"), jointly produced by WTCA and TPI. For project specific guidance, consult with project engineer/architecVgeneral contractor. MITek assumes no responsibility for truss manufacture, handling, erection, or bracing. 4) Provide adequate drainage to prevent water ponding. 5) Ali plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live Lds. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1606 lb upll�t at joint 1 and 1606 lb uplift at joint 11. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 3,2018 WARNING - VerIfy de.Ign p .. meters and RE417 NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mfl-7473 rev. 1010312015 BEFORE USF_ Design valid for use only with M]TekO connectors. This design is based only upon parameters shown, and Is for an lndlvldu�d building component. not a truss system. Before use. the building designer must verify the applicability of design parameters and property Incorporcite, this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Wit MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage. delivery; erection and bracing of trusses and truss system% seeANSI/TPI 1 Quality Cdleria, DSB-89 and BCSI Building Component Safety Information ovallat-Ae from TrLm Plate Institute. 218 N.'Lee Street—S Wile 312, Alexandria. VA 22314. 6904 Parke East Blvd. Tampa, FL 33610 Job Truss Truss Type oty Ply WAREHOUSE T1 3947128 74762 A10 Hip 2 1 � Job Reference (optional) 0 1 Qn o KAar 11 2018 MiTek 1 ndustries !nc- Thu May 3 12* 1 ';*r'A Pol 8 Pacia I Chambers Truss, irru., ruit riefue, rL I D: I IhBm4QCiiH Fi EguZxwhU PyGzMP-h4v9ktOlx2kO5MP-eogylckORw4dne-pbY1 IiCzKD�_q 2 1 -11-2 -4-0 53-8-5 61�4 7-7-11 1 -0�O Ll 4_ ' 4 30-8-0� 39 1 - i �_J 9_� -3-2 -4-14 -4- 7-7-11 4-4- �4 9-3-2 9 E 4 5 Scale = 1:104.6 6xlO MTIGHS 4x4 = 6xl 0 MT1 8HS = 6x10 MT18HS= 4.00FI-2 6X1 0 MT1 8HS 3x4 11 4x4 3x4 z�-311 3 3233 4 345 6 -7 35 8 3637 9 3x4 2 1038 30 30 39 19 18 17 16 15 14 13 12 4xlO 4x4 6x8 5XG �4x8 5X6 6X8 4x4 4xi 0 exio 11 6x10MT18HS= 8Xl0 11 0-9 200 �1 30-8-0 39-11-2 49-4-0 53-8-5 60-4-0 61-4 10 1 6-7- 4 1 �44 9_ 1'4 1 9-3-2 9 -3-2 9 -4-14 4 -4-5 6-7-111 110-0 Plate Offsets (X,Y)-- [1:0-1-2,Edgel, [3:0-6-4,0-3-01,[5:0-5-0,Edqe1, [7:0-5-0,Edgel, [9:0-64,0-3-01, f11:0-1-2,Edqe1 LOADING (psf) SPACING- 2-0-0 CS11. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.43 Vett(LL) -0.74 15 >991 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.41 Vert(CT) -1.37 15 >539 240 MT1 8HS 2441190 BCLL 0.0 Rep Stress Incr YES WB 0.77 Horz(CT) 0.24 11 n/a n/a BCDL 10.0 Code FBC20171TPI2014 Matrix -MS WInd(LQ 1.24 15 >593 240 Weight: 392 lb FT = 20% LUMBER- �RACING- -rOP CHORD 2X6 SP 240OF 2.OE TOPCHORD BOT CHORD 2X6 SP 240OF 2.OE BbTCHORD WEBS 2x4 SP No.3 *Except* BS 3-17,4-15,8-15,9-14: 2x4 SP M 30 V�?IEQGE Left: 2x4 SP NoA Right: 2x4 SP No.3 REACTIONS. (lb/size) 1=2269/0-8-0, 11=2269/0-8-0 Max Horz I =1 02(LO 11) Max Uplift 1=-1 606(LC 12). 11 =-1 606(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-5212/4539, 2-3=-5184/4485, 3-4=-735916404, 4-6=-811917003, 6-8=-8119/7003, 8-9=-7359/6404,9-10=-5184/4485, 10-11=-6212/4540 BOTCHORD 1-19=-4138/4836,17-19=-4051/4918,16-17=-6100/7359,14-15=-608817359, 12-14=-4039/4918, 11-12=-4126/4836 WEBS 2-19=0/344, 3-19=-4/297, 3-17=-2294/2762, 4-17=-899/950,4-15=-678/929 6-15=-486/598, 8-15=-678/929, 8-14=-899/950, 9-14=-2294/2762, 9-12=4i�97, 10-12=0/344 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL--4.2psf; BCDL=3..Opsf; h= 3 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(l) 3-0�( 53-6-15, (nterior(l) 53-6-15 . to 61-4-0 zone; cantilever left and right exposed ;C-C for members and f, shown; Lumber DOL=1.60 plate grip DOL=1.60 3) WARNING: This long span truss requires extreme care and experience for proper and safe handlln�, handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Me Trusses ("BCSI"), jointly produced by WTCA and TPI. For project specific guidance, consult with pro contractor. MiTek assumes no responsibility for truss manufacture, handling, erection, or bracing. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live 7) * This truss has been designed for a live load of 20.Opsf on the bottorn, chord in ail areas where a rec will fit between the bottom chord and any other members. 8) Pr6lde mechanical connection (by others) of truss to bearing plate capable of withstanding 1606 lb at joint 11 . Structural wood sheathing directly applied or 3-5-1 oc purlins. Rigid ceiling directly applied or 4-2-6 oc bracing. 1 Row at midpt 3-17,9-14 ; B--45ft; L=24ft; eave=7ft; Cat to 12-0-0, Exterlor(2) 12-0-0 to rces & MWFRS for reactions and erection. For general if Plate Connected Wood �ct engineer/architect/general gle 3-6-0 tall by 2-OL-0 wide ft at joint 1 and 1606 lb uplift Joaquin Velez PE No.68182 MITek USA, Inc. FL Cert 8834 6904 Parke East Blvd. Tampa FL 33610 Date: May 3,2018 WARNING -Vefify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11­7473 rev. 10)V 12015 BEFORE USE , Design valid for use onlywith MilekO connectors. IhIsclesign Is based only upon parameters shown. and Is for an Individual building component. not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall buildingdesIgn. Bracing Indicated Is to prevent bucking of Individual truss web and/or chord members only. Additional temporary and permanent bracing Mel( Is always required for stab4lity and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the 6904 Parke East Blvd. fabricatiom storage. delivery, erection and bracing of trusses and truss systems. seeANSI/Tpl I Quality Criteria, DSB-89 and BbSI Building Component Safety Information available from Truss Plate Institute. 218 N. Lee Street Suite 312, Alexandria, VA 22,314. 11 -Tampa, Fl. 33610 Job Trus Truss Type Qty Ply WAREHOUS Tl 3947129 74762 All Hip 2 1 Job Reference (optional) Lmarriners Truss, Inc., 6- -1 Fort Pierce, FL 000 844 2 -13- 2 8.130 s Mar 1 1 2018 101 1 Ck 1 FRJUSLI leb, 1 Hf:�. i , u may o i 4. i u­ �v P a age 1 ID: 1 [hBm4QCiiHFiEguZxwhUPyGzMP-AGSNyDl wiLsFjW—BCWBBIpHBcKOI W5ayqCnrEezKD—p 34-9-4 4%121-,312 140 493 -50 _6_1 3 3g� B-2-8 3g� Scale= 1:104.5 4.00 F12— 6xlO MT18HS 4x4 6xlO MT18HS 4x4 6xi 0 MTl 8HS = 3x4 11 4x12 6x8 2 32 3334 3 354 5 6 -7 36 8 3738 39 9 31 40 30 17 4 1 10 "41 7 10 — CQ 6 19 17 18 6 14 13 11 15 12 5xlo 3x4 11 6x8 4x4 4�8 3X4 11 4x6 5xl0 7x`10 11 48 M MT�PHS = 6xlO MT18HS = 7XIO 11 18-4-4 LOADING (ps" SPACING- 2-0-0 CS1. DEFL in (loc) I/defl Ud TOLL 20.0 Plate Grip DOL 1.25 TO 0.40 Vert(LL) -1.00 14-16 >734 360 TCDL 7.0 Lumber DOL 1.25 SO 0.53 Vert(CT) -1.87 14-16 >394 240 BOLL 0.0 Rep Stress Incr YES WB 0.81 Horz(CT) 0.29 10 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matflx-MS Wind(LL) 1.6714-16 >441 240 LUMBER- BRACING - TOP CHORD 2X6 SP 240OF 2.OE TbP CHORD BOTCHORD 2X6SP240OF2.OE B&CHORD WEBS 2x4 SP No.3 *Except* WEBS 2-17,3-16,5-14,8-14,8-11: 2x4 SP M 30 WEDGE Left: �x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (lb/size) 1=2269/0-8-0, 10=2269/0-8-0 Max Harz 1 =85(LC 11) Max Uplift 1=-1606(LC 12), 10=-1606(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-5302/4545, 2-3=-805216957, 3-5=-9490/8142, 5-6=-9489/8138, 6-8=-94,489/8,138, 8-9=-4996/4433, 9-10=-5300/4541 BOTCHORD 1-19=-4139/4940,17-19=-4134/4943,16-17=-6699/8052,14-16=-7884/9490, 13-14�6691/8052,11-13=-6691/8052,10-11-4123/4938 WEBS 2-19=0/251. 2-17=-2846/3474, 3-17=-1 107/1102, 3-16=-1 265/1614, 5-16=-45W542, 6-14=-434/543, B-14=-1 277/1612, 8-13=0/347, 8-11 =-3425/2811, 9-11 =-946/1338 � PLATES GRIP MT20 244/190 MT18HS 244/190 Weight: 381 lb FT = 20% Structural wood sheathing directly applied or 3-0-15 oc purlins. Rigid ceiling directly applied or 3-7-14 oc bracing. 1 Row at midpt 2-17, 3-16, 5-14, 8-14, 8-11 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=l 70mph (3-second gust) Vasd=l 32mph; TCDL=4.2psf; BCDL=3.Opsf; J�ft; B=45ft; L=24ft; eave=7ft; Cat 11; Exp, C; Encl., GCpl=O.l 8; MWFRS (directional) and C-C Extedor(2) 0-0-0 to 3-0-0, Interior(l) 3-0-',0 to 10-0-0, Extedor(2) 10-0-0 to 55-6-15, Interior(l) 55-6-15 to 61-4-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) WARNING: This long span truss requires extreme care and experience for proper and sale handling� and erection. For general handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses ("BCSI"), jointly produced by WTCA and TPI. For project specific guidance, consult with project engineer/architeettgeneral contractor. MiTek assumes no responsibility for truss manufacture, handling, erection, or bracing. 4) Provide adequate drainage to prevent water poncing. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opst on the bottoirn chord in all areas where a rectan1gle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 1 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1606 lb uplift at joint 1 and 1606 lb uplift at joint 10. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6834 6904 Parke East Blvd. Tampa FL 33610 Date: May 3,2018 WARNING -Verify design parameters and RE4D NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473re� laW)2015 BEFORE USE. Design valid for use only with MITek9 connectors. This design Is based only upon parameters shown, and Is for an individuai building component, not' a truss system. Before use. the building designer must vedfy the applicability of design parameters and properly InCOrpoTatb this design Into the overall bulldling design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always recitified for stability and to prevent collapse with possible personal Injury and property damage. For general guioance regardng the I I fabrica loft storage, delivery, ereellon and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI BuIlding Component 6904 Parke rast Blvd. Safety information available from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria. VA 22314. Tampa, FL 33610 Job Truss Truss Type aty Ply WAREHOUSE T1 3947130 74762 FLA FLOOR 21 � &A Job Reference (optional) 44nn4o­;� u! A Ili ! Th" KA � 4offilnece 2018 Pa e 1 Chambers Truss, inc., Fori Pjeice, rL . 3 "i I . _y ID:IlhBm4QCiiHFiEgu�;hUPyGMP-IyJgu?CiPfd'GPg2tOSRUsmsROz5-oO7O2OAbjqzKD - b 2-6-0 2-0-0 1 1-4-1 1 1-4-1 OAS Scale = 1:50.2 3X4 11 4x10 2X3 11 3x5 2X3 1 2 3 4 5 4�_ 26 25 24 23 4X6 4x12 3X6 FP = 3x8 5xl2 MT18HS SP = 5X6 2X3 11 4X4 = 2X3 11 3x6 FP = 3X4 2X3 11 4x6 6 7� 81 10 11 12 13 V\N� _6 . 22 21 20 19 SX6 4,x4 3X4 4X8 14-7-2 ID-4-8 6X8 2X3 11 3X4 = 14 15 16 18 17 5xl2 2X3 cp 919 Plate Offsets (X,Y)-- [1: Edqe,0-1 -81, [7:0-1 -8, Edgel, [8:0-1-8,0-0-01, [11:0-1-8, Edijel, [11 6:OT1 -8, Edge], [17:0-1-8, Edge 1, 120:0-1 -8, Lage 1, 121 :u-1 -t3, tage 1, 1 zz:o-i -u, tage 1 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.96 Vert(LL) -0.57 22 >602 480 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.87 Vert(CT) -0.79 22 >438 360 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.93 Horz(CT) 0.02 16 n/a n/a BCDL 5.0 Code FBC2017fTP]2014 Matrix-S Weight: 165 lb FT = 20%F, 11 %E LUMBER- BRACING- T"OP CHORD 2x4 SP M,90(flat) T6PCHORD Structural wood sheathing directly applied, except end verticals. BOTCHORD 2X4 SP M 30(flat) *Except* 136TCHORD Rigid celling directly applied or 10-0-0 oc bracing. 17-24: 2x4 S P M 31 (flat) WEBS 2x4 SP No.3(flat) *Except* 16-18: 2x4 SP M 30(flat) REACTIONS, (lb/size) 26=1579/0-6-4,16=1579/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-3615/0, 3-4=-3615/0, 4-5=-5594/0, 5-6=-5594/0, 6-7=-6020/0, 7-8=-6020/0,, 8-1 0=-6020/0, 10-11 =-5596/0,11-12=-4797/0,12-13=-4797/0,13-14=-2039/0 14-16=-204310 BOTCHORD 25-26=0/2033, 23-25=0/4781, 22-23=0/5992, 21-22=0/6020, 20-21 =0/5840, 19-2 - =0/5596, 18-19=0/3596 WEBS 7-22=-642/413, 8-21 =-438/84, 2-26=-2498/0, 2-25=0/1 960, 4-25=-1 445/0,4-23=0)0 007, 5-23=-260/0, 6-23=-731/0, 6-22=-547/820,16-18=0/2477,13-18=-1930/0,13-19=0/1487, 12-19=-269/0,11-19=-982/0,11-20=0/392,10-20=-539/0,10-21=-2411760 NOTES- I 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) The Fabrication Tolerance at joint 24 = 11 % 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss, 1, (0.131 X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between Inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6) CAUTION, Do not erect truss backwards. Joaquin Velez PE No.68182 MlTek USA, Inc. FIL Cert 6834 6904 Parke East Blvd. Tampa FL 33610 Date: May 3,2018 WARNING - Verify deal _qn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. 10/03,2015 BEFORE USE Design valid for use ordy with 1011709 connectors. This design Is based only upon parameters shown, and Is for an Individual,bullding component, not a Iruss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this deslon Into file overall buildiing design, Bracing Indicated Is to prevent buckling of Individual tam web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabitcallom storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safely Information avallable from 1russ Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22,314. Tampa, FL 33610 job * Truss Truss Type Qly Ply WAREHOUSE T139471311 74762 GRA HIP GIRDER 2 3 Job Reference (optional) (;naMbers iruss, Inc., I-ort Fierce, t-L '. 4-7-14 , 8-0-0 . 13-9-5 5-7-9 t3. IOU b IVIdl I I 4U 10 IVII I UN I I IUU-11—, H — I ]IU IV-y . —. .V. , ID:llhBm4QCiiHFiEguZxwhUPyGzMP-PGIDP6LEbLBZrWzAjzflLlMabplAcxOnoF4D98zKD�-P 3-4-2 ' 4-7-14 NAILED NAILED NAILED NAILED NAILED 4.00FI-2 SX14 MT18HS = NAILED NAILED NAILED NAILED �11NAILED NAILED NAILED NAILED NAILED NAILED 8x14 MT18HS Special NAILED NAILED NAILED 10x10 W8= NAILED 3x6 11 NAILED 10x10 WB = NAILED NAILED Special 2 34 35 33637 3839 440 41425 6 43 44 745 4647 488 4950 95, 10 525354 115556 67 5812 to u 25 24 22 21 19 67 686970 18 71 72 17 737416 15 75 76 14 59 60 23 61 6263 64 65 66 20 5X8 3X6 11 NAILED WO = NAILED NAILED 8 = NAILED NAILED NAILED 5x6 M 11 Special 7x8 IVITit Special 5x6 = NAILED NAILED �HS = NAILED NAILED IBM = NAILED NAILED NAILED NAILED NAILED NAILED NAILED NAILED NAILED NAILED �AILED NAILED 41-11-2 . 47-6-11 1 53-4-0 , 56-8-2 LOADING (psf) SPACING- 2-0-0 CSI. in (loc) Vdefi Ud 1 ).0 TCLL 1 0 Plate Grip DOL 1.25 TC 0.63 V I(C �D.E'Fl- L) 1.65 19 >446 240 TICDL 7.0 Lumber DOL 1.25 BC 0.40 ert(CT) -1.58 19 >465 240 BCLL 0. Rep Stress Incr NO WEI 0.40 orz(CT) -0.19 13 n/a n1a BCDL 10. Code FBC2017/TPI2014 Matrix -MS LUMBER- -rOP CHORD 2X8 SP 240OF 2.OE *Except* 1-2,12-13: 2x6 SP No.2 BOT CHORD, 2x8 SP 240OF 2.OE WEBS 2x4 SP No.3 *Except* 2-24,3-22,4-21,6-19,8-19,10-18,11-17,12-15:2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (lb/sIze) 1=4487/0-8-0,13=4487/0-8-0 Max Harz 1 =-68(LC 23) Max Uplift 1 =-3786(LC 8), 13=-3785(LC 8) Scale = 1:102.8 5X8 = PLATES GRIP MT20 244/190 MT18HS 244/190 Weight: 1398 lb FT = 20% CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-10648/9078, 2-3=-17497/14959, 3-4=-22143/18863, 4-6=-25036/21304, 6-7=-26016/22127, 7-8=-26016/22127, 8-1 0=-25036/21304, 10-11 =-22141/18861, 11 -1 2=-1 7496/14958,12-13=-1 0647/9077 BOTCHORD 1-25=-B446/9992, 24-25=-8424/9975, 22-24=-14781/17494, 21-22=-18689/22143, 19-21=-21130/25036,18-19=-21130/25036,17-18=-18687/22141,15-17=-14780/' 14-15=-8424/9974,13-14=-8445/9991 WEBS 2-25=-312/391, 2-24=-6984/8315, 3-24=-2942/2684, 3-22=-4295/5124, 4-22=-193 4-21 =-2683/3203, 6-21 =-1 059/1094, 6-19=-905/1099, 7-19=-639[762, B-19=-905/1 8-18=-1059/1095, 10-18=-268613205,10-17=-1934/1829,11-17=-4294/5123, 11-15=-2942/2684,12-15=-6983/8314,12-14=-312/391 NOTES- 1) 3-plytrussto be connected togetherwith 10d (0.131"x3") nailsas follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0�oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LL ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicate 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=23ft; B- 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed; Lumber DOL=1.60r 5) WARNING: This long span truss requires extreme care and experience for proper and safe handling an�, handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal P Truises ("BCSI"), jointly produced by WTCA and TPI. For project specific guidance, consult with project i contractor. MiTek assumes no responsibility for truss manufacture, handling, erection, or bracing. 6) Provide adequate drainage to prevent water ponding. 7) All plates are MT20 plates unless otherwise Indicated. 8) All plates are 4x5 MT20 unless otherwise Indicated. CAS E(S) section. Ply to 45ft; L=24ft; eave=7ft; Cat. ate grip DOL=1.60 erection. For general ite Connected Wood 13 Cb Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 8634 6904 Parke East Blvd. Tampa FL 33610 Date: May 3,2018 WARNING. Verify des�lqn parameters and READ NOTES ON THIS AND INCLUDED mrrEKREFERANcE PAGE M11-7473 mv. 1010ah?016 BEFORE USE. Design valid for use only with MlTek8 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, riot a truss system. Before use, the bulldlng designer must verify the applicability of design parameters and property Incorporate4his design Into the overall buildingdesign. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only, Additional teftiporary and permanent bracing WeIC Is always required for stability and to prevent collapse with possible personal Injury and property clamage. For general guk:16�ice regarding the fabilcatiom storage, delivery, erection and bracing of Inisses and truss systems, seeANSI/Tpl I Quality Criteria, DSB-89 and BCSf Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FIL 33610 Job Truss Truss Type aty Ply WAREHOUSE T13947131 74762 GRA HIP GIRDER 2 1 3 Job Reference (optional) Chambers Truss, Inc., F-on I-lerce, t-L .. I .. . 1� ... � I — I ­.. . 6 u. 111- .... I—, - . . . u ID:1 IhBm4QCiiHFiEguZxwhUPyGzMP-PGI DP6LEbL8ZrWzAjzf]LlMabp]AcxOnoF4D98zKD-P NOTES- 10) * This truss has been designed for a live load of 20.Opsf on the bottom chord� In all areas where a rectangle 3-6-0 tall by 2-0-0 Wide will fit between the bottom chord and any other members. I 11) Provide mechanical connection (by others) of truss to bearing plate capable �f withstanding 3786 lb uplift at joint 1 and 3785 lb uplift at joint 13. 12) "MAILED" indicates 3-1 Od (0. 1 48"x3") or 3-12d (0.1 48"x3.25") toe -nails per NDS guldlines. 13) Hanger(s) or other connection device(s) shall be provided sufficient to support �pncentrated load(s) 197 lb down and 375 lb up at 8-0-0, and 197 lb down and 375 lb up at 53-4-0 on top chord, and 303 lb down and 320 lb up at 8-0-0, and 303 lb down and 320 lb up at 53-3-4 on bottom chord. The design/selection of such connection device(s) Is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber lncrease=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54, 2-12=-54,12-13=-54,1-13=-20 Concentrated Loads (lb) Vert: 2=-1 50(F) 5=-1 09(r) 12=-1 50(F) 23=-52(F) 25=-303(F) 24=-52(F) 39=-109(F) 40=-109(F) 41=-109(F) 43=-109(F) 44=-109(F) 45=-109(F) 54=-1 09(F) 56=-1 09(F) 58=-1 09(F) 59=-52(F) 60=-52(F) 61 =-52(F) 62= 71=-52(F) 72=-52(F) 73=-52(F) 74=-52(F) 75=-52(F) 76=-52(F) 09(F) 11 =-1 09(F) 15=-52(F) 14=-303(F) 16=-52(F) 34=-1 09(F) 36=1 09(F) 38=-109(F) 109(F) 47=-109(F) 48=-109(F) 49=-109(F) 51=-109(F) 52=-109(F) 53=-109(F) :) 63=-52(F) 64=-52(F) 65=-52(F) 66=-52(F) 67=-52(F) 68=-52(F) 69=-52(F) 70=-52(F) WARNING - Verity desIgnparameters andREAD NOTES ON THIS AND INCLUDED UITEKREFERANCE PAGE Ulf-7473 rev. 10/03,2015 BEFORE USE Design valid for use only with MITek9 connectors. 1his design is based only upon parameters shown. and Is for an lndlvldua'l building component, not a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design Into the over( 311 building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTeW Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fobtication, storage, delivery. erection and bracing of trusses and truss systems. seeANSIJTPI I Quality Criteria, DSB-89 and 6CS1 Building Component 6904 Parke East Blvd. Safety Information avallable from TFuss Plate Institute. 218 M. Lee Street, Suite 312. Alexandria, VA 2231 A. Tampa, FIL 33610 Job Truss Truss Type city Ply WAREHOUSE TI 3947132 74762 J 1 JACK -OPEN 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 Mi I ek industries, inc. Thu May 112: 116:211 20i 8 Page 1 1 2-0-0 1 D: 1 IhBm4QCiiHFi EguZxwhUPyGzMP-tSbbdSMsLeGQSfYNHgAXuVusgDiyLUwxi vpnhazKD-O 2-0-0 I Scale = 1:8.7 0 7 C� 9 0 3X8 11 LOADING (psf) TCLL 20.0 T-CDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/TP12014 CS1. TC 0.16 BC 0.17 WE 0.00 Matdx-MP I DEFL. In Vert(LL) -0.00 ert(CT) -0.00 Horz(CT) -0.00 �V Wind(LL) 0.00 (loc) I/defl Ud 4 >999 360 4 >999 240 1 n/a n/a 4 >999 240 PLATES GRIP MT20 244/190 Weight: 9 lb FT = 20% LUMBER- �RACING- fOP CHORD 2X4 SP N0.3 TOPCHORD Structural wood sheathing directly applied or 2-0-0 oc purlins. BOTCHORD 2x4 SP No.3 BbTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDGE Left: 2x6 SP �o.2 REACTIONS. (lb/size) 2=1/Mechanical, 3=-2/Mechanical, 1=148/0-8-0 Max Horz 1 =44(LC 12) Max Uplift 2=-12(LC 12),3=-1 1 (LC 12), 1=-176(LC 12) Max Grav 2=4(LC 17), 3=2(LC 3), 1 =1 48(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h,=23ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) zone; cantileverleft exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opst on the bottom chord in all areas where a� rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 12 lb Lplift at joint 2, 11 lb uplift at joint 3 and 176 lb uplift at joint 1. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6834 69D4 Parke East Blvd. Tampa FL 33610 Date: May 3,2018 AWARNIAIG - Verity design prameters and RE40 NorEs ori ru[SAND iNcLuDED mrrEKREFERANcE PAGE —747. 1.0.2015 BEFOREUSE. Design valid for use only with MITek9 connectors. This design Is based orgy upon parameters shown, and Is for an IndIvIdu I Ilding component, not at bu a truss system. Before use. the building designer must veflfy the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTele fabdcation. storage. delivery. erection and bracing of trusses and truss systems, seeANSI/TPi I Quality Criteria, DSB-89 cnd BCSI Building Component 6904 Parke East Blvd. Safety Informotion available from Truss Plate Institute, 218 N. Lee Street, Suite 312, AlexandrIcL VA 22314. Tampa, Ft. 33610 Job Truss Truss Type City Ply WAREHOUSE T1 3947133 74762 J3 JACK -OPEN 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 3x4 � 3X8 11 a. i 3u s mar 11 ZU 18 MI 19K I naustries, Inc. I nu may 3 12: 16:22 zu i b Page i I D: 1 IhBm4QCiiH R EguZxwhUPyGzMP-LfgzqoMU6yOH4p7ZrOhmQj R?2d? 1 4xA4GZZKDOzKD—N 4-0-0 F1 _2 Scale: 1'=I' Plate Offsets (X,Y)-- [1:0-0-0,0-0-151,[1:0-1-6,1-0-151 LOADING (pst) SPACING- 2-0-0 CS11. DIEFL. in (loc) Vdefl Ud PLATES - GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.31 Vert(LL) -0.00 4 >999 360 MT20 244/190 T-CDL 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.00 4 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 2 n/a n/a BCDL 10.0 Code FBC2017/-FP12014 Matrix -MP Wind(LL) -0.dl 4 >999 240 Weight: 16 lb FT = 20% LUMBER- 101P CHORD 2X4 SP N0.3 BOT CHO�D 2X4 SP NO.3 WEDGE Left: 2x6 SP 6.2 REA:CTIONS. (lb/size) 2=58/Mechanical, 3=13/Mechanical, 1=220/0-8-0 Max Harz 1 =88(LC 12) Max Uplift 2=-82(LC 12), 1=-127(LC 12) Max Grav 2=58(LC 1), 3=38(LC 3), 1 =220(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: AS C E 7-10; VUlt= 1 70Mph (3-second gust) Vasd=1 32m ph; TCD L=4.2psf; BCD L=3.Opsf; L2311; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp C; Encl., GCpl=O.l 8; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(l) �1-0-0 to 3-11-4 zone; cantilever left exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate brip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where aYectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 82 lb �pllft at joint 2 and 127 lb uplift at joint 1. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: May 3,2018 WARNING- VrIryde.Ig.paranreters and READ NOTES ON THIS AND INCLUDED MITSKREFERANCE PAGE 11111-7473re, 1010'3)2015 BEFORE USE. Design valid for use only with 101100 connectors. This design Is based only upon parameters shown, and Is for an incliviclud.1 building component. not a truss system. Before use. the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional l6mporary and permanent bracing M!Tek' Is always required for stability and to prevent collapse wilh possible personal Injury and property damage. For general gulaance regarding the fabrication. storage. clellvery� erection and bracing of trusses and truss systems. seeANSI/Tpi I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety information available from Truss Plate Institute. 218 N. Lee. Street, Suite 312, Alexandria. VA 22314. Tampa, FL 33610 Job Truss Truss Type City Ply WAREHOUSE T1 3947134 74762 J5 JACK -OPEN 8 . I Job Reference (optional) unamners 1 russ, Inc., ron: vierce, rL ' 1 ju s rviar 11 ZU 10 IVII I BK inuustries, i nc. i nu may o i e: i o:zz eu i a rage i ID: 1 IhBm4QCii HFitE% guZxwhU PyGzM P-LfgzqoMU6yOH4p7ZrOhmQiR_.pdvD4xA4GZZKDOzKD�_N 6-0-0 6-0-0 Scale 1:15.4 2 2 0 F1 _2 7 3x4 3 3xB I I '_�_2 6-0-0 1-0-0 16-4-01 4-8-0 Plate Offsets (X,Y)-- [1:0-0-0,0-0-151,[1:0-1-6,1-0-151 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/clefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.34 Vert(LL) -0.02 3-7 >999 360 MT20 244/190 TCDI_ 7.0 Lumber DOL 1.25 BC 0.74 Vert(CT) -0.04 3-7 >999 240 BCLIL 0.0 Rep Stress Incr YES WEI 0.00 Horz(CT) -0.03 2 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP WInd(LL) -0.07 4 >999 240 Weight: 22 lb FT = 20% IJUMBER- BRACING - TOP CHORD 2X4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. I BOT CHORD. 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDGE - Left: 2x6 SP No.2 REACTIONS. (lb/size) 2=113/Mechanicai,3=43/Mechanicai,1=283/0-8-0 Max Harz 1 =1 32(LC 12) Max Uplift 2=-143(L C 12), 3=-2(LC 12), 1 =-1 66(LC 12) Max Grav 2=1 13(LC 1), 3=80(LC 3), 1 =283(LC 1) FORCES. (lb), Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=1 70mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.0p�f; h=23ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp C; Encl., GCpl=O.l 8; MWFRS (directional) and C-0 Exterior(2) 0-0-0 to 3-0-0, Interior(l) 3-0-0 to 5-11-4 zone; cantilever left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any otiier live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 Wide will fit between the bottom chord and any other members. I 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding J3 Ib uplift at joint 2, 2 lb uplift at joint 3 and 166 lb uplift at joint 1. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: I May 3,2018 ,& WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED UTTEKREFERANCE PAGE M11-7473re I �. 10103J2015 BEFORE USE. Design valld for use only with MffekO connectors. This design Is based only upon parameters shown, and Is for an [ndIvIdual building component. not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incoliporafe this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damage. For gener�pl guidance regarding the MiTek' fabrication, storage, clellvery� erection and bracing of trusses and trurss systems. seaANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety information avallable from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314. 1 Tampa, FIL 33610 Job Trus Truss Type Qty Ply WAREHOUS E T1 3947135 74762 J7 JACK -OPEN 48 Job Reference (optional) unamDers -I russ, mc., t-011 MerCO, t-L VAOU S Mar I I 4U 10 IVII I UK J I HJUbUlUb. 111G. I I 1U lVidy 0 14; 10o�O �u 10 rdyu I I D: 1 IhBm4OCii HFiEguZxwhUPyGzM P-prjL1 8N7tGWBizj[05C?zW-54OLgpOQEVDItiTzKD—M 8-0-0 8-0-0 i i 2 Scale = 1:19.2 40 5_2 9 C�. 3X5 1><1 I>< 3X8 11 7 N C6 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.61 Vert(LL) -0.07 3-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC Vert(CT) -0.15 3-7 >655 240 EICLL 0.0 Rep Stress Incr YES WE, Horz(CT) -0.07 2 n/a ri/a BCDL 10.0 Code FBC2017/TP[2014 Matrix -MP Wind(LL) -0.14 4 >667 240 Weight: 28 lb FT = 20% LUMBER- �,BRACING- TOP CHORD 2X4 SP M 30 �TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOVCHORD 2x4SPM30 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDGE Left: 2x6 SP No.2 REACTIONS. (lb/size) 2=163/Mechanlcal, 3=72/Mechanical, 1=353/0-8-0 Max Harz 1=177(LC 12) Max Uplift 2=-198(LC 12),3=-9(LC 12), 1=-209(LC 12) Max Grav 2=163(LC 1), 3=120(LO 3), 1=353(LC 1) FORCES. (lb) -Max. Comp.lMax. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.01 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) 0-0-0 to 3-0-0, Interio exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 r 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any ( 3) * This truss has been designed for a live load of 20.Opst on the bottom chord in all areas wh will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding and 209 lb uplift at joint 1. h=23ft; B=45ft; L=24ft; eave=4ft; Cat. 3-0-0 to 7-11-4 zone; cantilever left grip DOL=1.60 r live loads. a rectangle 3-6-0 tall by 2-0-0 wide uplift at joint 2, 9 lb uplift at joint 3 Joaquin Velez PE No.68182 MiTek USA, Inc. Fl. Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: Mav 3,2018 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11­7473 rev. 10/03,2015 BEFORE USE. Design valid for use only with MITeM connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the bulldIng designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stab4lity and to prevent collapse with possible personal Injury and property damage. For general buldance, regarding the fabrication. storage, delivery. erection and bracing of trusses and in= systems. seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 33610 1 Job Truss Truss pe I Oty Ply WAREHOUSE I k T1 3947136 74762 KJ7 DIAGONAL HIP GIRDER 4 1 1. Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL !I 5-8-0 IjL 8.130 s Mar 11 2018 MITeK Industries, Inc. I rIU May 3 12:115:24 2U18 vage I ID:1 IhBm4QCiiHFiEguZxwhUPyGzMP-HlGjFUO[eZe?J7HyypjEWBWKgQgBYoaNjt2RIvzKD-L 11-3-0 2.83 F12 13 3X4 12 3X5 14 15 6 16 2X3 3X8 3X10 5 3A t2 d, 6 = 1:19.7 Plate Offsets (X,Y)-- [1:0-0-0,0-1-01,fl:O-2-7,Edqel,[1:0-2-3,1-9-101 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.33 Vert(LL) 0.07 5-6 >999 240 MT20 244/190 rCDL 7.0 Lumber DOL 1.25 BC 0.33 Vert(CT) -0.08 7 >999 240 BCLL 0.0 Rep Stress Incr NO WEI 0.20 Horz(CT) -0.03 3 n/a n/a BCDL 10.0 Code FBC2017/-FP]2014 Matrix -MS Weight: 47 lb FT = 20% UJMBER- TOP CHORD 2X4 SP M 30 BOTICHORD 2X4 SP M 30 WEBS 2X4 SP No.3 WEDGE L7eft:.2x6 SP No.2 REACTIONSr. (lb/size) 3=118/Mechanical,4=280/Mechanical,1=48410-11-5 Max Harz 1=202(LC 4) Max Uplift 3=-1 38(LC 4), 4=-263(LC 4), 1 =-473(LC 4) FORCES. (lb) -Max. Comp./Max. Ton. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-516/432 BOTCHORD 1-6=-536/466, 5-6=-5361466 WEBS 2-5=-521/600 CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. CHORD Rigid ceiling directly applied or 9-7-14 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.0psf; hiMt; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left exposed; Lumber DOL--,1.60 plate grip DOL"1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other ]I , ve loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 138 lb'uplift at joint 3, 263 lb uplift at joint 4 and 473 lb uplift at joint 1. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) � 01 lb down and 42 lb up at 2-11 -0, 101 lb down and 42 lb up at 2-11-0, 37 lb down and 93 lb up at 5-8-15, 37 lb down and 93 lb up at 5-8-15, and 68 lb down and 163 lb up at 8-6-14, and 68 lb down and 163 lb up at 8-6-14 on top chord, and 0 lb down and 39 lb up at 2-11-0, 0 lb down and 39 lb up at 2-11 -0, 10 lb down and 4 lb up at 5-8-15, 10 lb down and 4 lb up at 5-8-15, and 33 lb down and 14 lb up at 8-6-14, and 33 lb down and 14 lb up at B-6-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. I 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B)4 LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 4-7-20 Concentrated Loads (lb) Vert: I 1=42(F=21, 9=21) 13=-73(F=-36, B=-36) 15=8(F=4, B=4) 16=-30(F=-15, B=-1 5) Joaquin Velez PE No.68182 MiTek USA, Inc. FIL Cert 8634 6904 Parke East Blvd. Tampa FL 33610 Date: May 3,2018 WARNING- Verity design parameters and READ NOTES ON THISAND INCLUDED MITEKREFERANCEPAGEM11-7473rev. 1010�2015 BEFORE USE. Design valid foruse onlywilh MiTek9 connectors. Thisclesign is basedonlyupon parameters shown, and Isforan Individual building component, not a truss sysierri. Before use, the building designer must verity the applicability of design parameters and properly Incorporat& this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional te'�mporary and permanent brac-Ing MiTeW Is always recligred for stability and to prevent collapse with possible personal Injury and property damage. For general guiciance, regarang the labricaflort storage, clelivery� erection and bracing of trusses and miss systems� seeANSI/TPI 1 Quality Criteria, DSB-89 and 8CS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22,314, Tampa, FIL 33610 Symbols Numbering System � A General Safety Notes PLATE LOCATION AND ORIENTATION 14 /�' Center plate on joint unless x, y -13 offsets are indicated. Dimensions are in ff-in-sixteenths, Apply plates to both sides of truss and fully embed teeth, 0-,/14, For 4 x 2 orientation, locate plates 0-11i�' from outside edge of truss. This symbol indicates the required direction of slots in connector plates, *Plate locafion details available in MiTek 20/20 software or upon request PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicuk -------to-sic)ts.—Se,con-d—dimens—ion i's the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. 117_5�_;q Min size shown is for crushing only. CEM Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 0 6-4-8 dimensions shown in ff-in-sixteenths I (Drawings not to scale) 2 3 TOP CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESIR4311TIESU- 352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 0 0 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. @ 2012 MiTek@ All Rights Reserved Nil MiTek MITek Engineering Referenc8h Sheet: PAII-7473 rev. 10/03/2015 Failure to Follow Could Cause Property Damage or Personal injury I . Additional stability bracing for truss system, e.g. diagonal or X-brocing, is always required. See SCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stock materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear fightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane atjoInt locations are regulated by ANSI/TPI 1, 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retacdont-preservative-treated,—(:�r —green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to comber for dead load deflection. 11 . Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified, 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or after truss member or plate without prior approval of on engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI I Quality Criteria,