Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEANE FORM R405-2017 St Lu FLORIDA ENERGY EFFICIEN, Florida Department of Business and P E FOR BUILDING CONSTRUCTION nal Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT SC Builder Name: WYNNE DEVELOPMENT NNED Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, BY Permit Number: E Owner: �u ie coun4itfrisdiction: Design Location: FL, Fort Pierce ?Ounty:: St. Lucie (Florida Climate Zone 2 1. New construction or existing New (From Plans) 9. Wall Types(1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R--4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=1 1.0 208.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1753.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade (ft2) 1753 b. N/A R= ft2 Conditioned floor area below grade (fl:2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(151.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 225 a. U-Factor: SgI, U=0.63 111.36 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems a. Electric Cap: 40 gallons 8. FloorTypes (1753.0 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed I �Iodified Loads: 53.83 Glass/Floor Area: 0.086 I PASS Total Baseline Loads: 53.85 1 her6by certify that the plans and specifications covered by Review of the plans and If 114E Sr this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance n,, with the Florida Energy Code. IPRE'PAR.. Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in comp iance Florida Statutes. with the Florida Energy Code. 'n WF' OWNERg/�� BUILDING OFFICIAL: DATE: DATE: I - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1.1 - Compliance requires an Air Barrier and Insulation Insp I ection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). a 4/16/2018 8:46 PM EnergyGauge@ USA - FI Res2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Tifle: WYNNE THE WINDSOR IM Bedrooms 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stori I as: 1 Block/Subdivision: # of Units: I Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate 225 Street: THE WINDSOR 2le. Permit Office: ST. LUCIE COUNTY Cross Ve t tilation: No County: St. Lucie io Jurisdiction: Whole Ho se Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL—VERO—BEACH—MUNI 39 90 70 75 299 62 Low I BLOCKS Number Name Area Volumel 1 1 Entire House 1753 14024 SPACES Number Name Area Volume lKitchen Occupants Bedrooms Infil ID Finished Cooled Heated I MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS V# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet I Slab -On -Grade Edge Insulatio MASTER BEDRO 3-1 ft 0 224 ft2 ---- 0 1 0 2SIab-On-Grade Edge Insulatio WIC I ft 0 63 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 ft2 ---- 0 1 0 4/16/2018 8:46 PM EnergyGauge@ USA - FIaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 FLOORS y# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 ---- 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN 11 ft 0 209 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 ---- 0 1 0 1 1SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 ---- 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 1 ft 0 169 ft2 ---- 0 1 0 ROOF Roo Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Are Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 164 t TV 292 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V# Type Ventilation Vent Ratio (I in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING V# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEII I RO 30 Blown 224 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic (Vented) DINING/GRE AT 30 Blown 588 ft2 0.1 Wood 8 Under Attic (Vented) I KITCHEN 30 Blown 209 ft2 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS # Adjacent Ornt In Wall lype Space Cavity Width R--Vahle Ff In Height Et In Area Sheathing Framing R-\Inl,le Eractoon Solar Ahqor Below Grarle% I NE=>W Exterior Concrete Block - Ext InaMASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.5 0 2 1 SW=>E Exterior Concrete Block - Ext In9MAS1 ER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 3 1 NW=>S Exterior Concrete Block - Ext InsMAS1 ER BE 1 4.1 14 0 8 0 11200 ft2 0 0 0.5 0 4 NE=>W Exterior Concrete Block - Ext In9hAAS1 ERbA 1 4ol 8 0 8 0 64.0 ft2 0 0 0.5 0 4/16/2018 8:46 PM EnergyGauge@) USA - F IaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 I WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below )lar Belod Ornt 10 Wall Tvpe Space R--Val-le Et In Et In Area R-Val-le Ernctffion Ah 5 NE=>W Exterior Concrete Block - Ext InsulM. BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 .6 NE=>W Exterior Concrete Block - Ext InEEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.5 0 7 SW=>E Exterior Concrete Block - Ext IndXNING/GRE - 4.1 30 0 8 0 240.0 ft2 0 0 0.5 0 8 NW=>S Exterior Concrete Block - Ext IndANING/GRE - 4.1 20 0 8 0 160.0 ft2 0 0 0.5 0 9 SW=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.5 0 10 NE=>W Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 11 SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 12 SW=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 13 NE=>W Exterior Concrete Block - Ext IndMDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 14 SW=>E Exterior Concrete Block - Ext In!EEDROOM 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 15 N=>SW Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.5 0 DOORS V# Ornt DoorType Space Storms I U-Value Width Height Area Ft In Ft In I SE=>N Insulated FOYER I None .39 3 3 6 8 21.7 ft2 WINDOWS 4tered Orientation shown is the orientation (=>) changed to Worst Case. V- Wall �U-Factor Overhang # Ornt ID Frame Panes NFRC SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.63 0.25 N 32.4 ft2 1 ft 0 in I ft 4 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 0.63 0.25 N 6.9 ft2 1 ft 0 in 1 ft4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft2 1 ft 0 in 1 ft4 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.63 0.25 N 39.8 ft2 1 ft 0 in 1 ft 4 in None None 5 NW=>S 8 Metal Low-E Single Yes 0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in None None 6 NE=>W 13 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft2 1 ftO in I ft4 in Drapes/blinds Exterior 5 GARAGE V# Floor Area Ceiling Area lExposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 1 INFILTRATION # Scope Method SLA C FM 1 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1'636.1 89.82 168.92 .2598 7 4/16/2018 8:46 PM EnergyGauge@ USA - F, IaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 kATING SYSTEM y # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 c60LING SYSTEM y # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HO� WATER SYSTEM I y# System Type SubType Location �F Cap Use SetPnt Conservation 1 Electric None Garage 97 40 gal 60.9 gal 120 deg None SOLAR �OT WATER SYSTEM VFSEC Cert # Company Name System Collector Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS V # Supply Location R-Value Area Return Location Area Leakage Type Air Han . dler CFM 25 TOT CFM25 OUT QN RLF HVAC # Heat Cool 1 Attic 6 225 ft2 Attic 60 ft2 Default Leakage Attic (Default) (Default) 1 1 #MPERATURES Prograrnable, Thermostat: Y Cooling Jan Feb He Jan Feb Ve Jan Feb Mar X Mar Mar Ceiling Aprr May A may Apr may I Fans: Jun Jul Jun Jul rl Jun ri Jul Aug Aug ri Aug Sep Sep �I Sep Oct Oct Oct Nov X Nov Nov Dec Dec Dec Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 — 12 Cooling (WD) Cooling (WEH) Heating (WD) Heating (WEH) AM PM AM PM AM PM AM PM 78 80 78 78 66 68 66 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 66 66 68 68 68 68 78 78 78 78 68 68 68 68 78 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 4/16/2018 8:46 PM EnergyGauge(D USA - FlIes2017 Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPEC I ION COMPONENT CRITERIA I TABLE 402.4.1.1 AIR BARRIER AND INSULAT iON INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CR,ITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed The exterior thermal envelope contains in the building envelope. a' continuous air barrier. Air -permeable insulation shall requirements Breaks or joints in the air barrier shall b� sealed. not be used as a sealing material. Ceiling/affic The air barrier in any dropped ceiling/soffit the insulation and any gaps in the air ba I shall be aligned with I rrier shall be sealed. The insulation in any dropped ceiling/soffit shall be aligned with the air barrier. Access openings, drop down stairs or kre wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plalte shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambsi and framing, and and doors skylights and framing shall be sealed. I Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any el xposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl space s shall be covered with Where provided instead of floor insulation, insulation I a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and fluel shafts opening to exterior or unconditioned space shall b el sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between t I ke garage and conditioned spac Ds. Recessed lighting I Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the sho�vers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behin� electrical or communication exterior walls boxes or air -sealed boxes shall be installied. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. I Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommend ed by the manufacturer. Caulking or other adhesive sealants s6l not be used to fill voids I between fire sprinkler cover plates and walls or ceilings - a. in addition, inspection of log walls shall be in accordance wit� tne provisions of ICC-400. 4/16/2018 8:46 PM EnergyGauge@) USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of I FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerfo �Imance Index, the more efficient the home. 1 . New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (fl:2) 7. Windows- Description a. U-Factor: Sgl, U=0.63 SHGC: SHGC=0.25 b. U-Factor: SgI, U=0.65 SHGC: SHGC=0.21 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A THE W1 New (From Plans) Single-family 1 3 Yes 1753 Area 111.36 fl:2 40.00 ft2 ft2 ft2 2.850 ft. 0.239 Insulation Area R=0.0 1753.00 ft2 R= ft2 R= ft2 FT. PIERCE, FL, 9. Wall Types a. Concrete Block - Ext Insul, Exterior b. Frame - Wood, Adjacent c. N/A d. N/A 10. Ceiling Types a. Under Attic (Vented) b. N/A c. N/A 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new E L Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New HomeNCL191 NN City/FL Zip7ZZIc�.\,_ e;;�,v Insulation Area R=4.1 1224.00 ft2 R=1 1.0 208.00 ft2 R= ft2 R= ft2 Insulation Area R=30.0 1753.00 ft2 R= ft2 R= ft2 R ft2 6 225 kBtu/hr Efficiency 34.8 SEER:15.00 kBtu/hr Efficiency 34.8 HSPF:8.50 Cap: 40 gallons EF: 0.97 .04E S 16. WE Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida En I 6rgyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Bul ilding Code, Energy Conservation, contact the Florida Building Commission's support staff. 1. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1 4/16/2018 8:46 PM EnergyGauge@ USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1