HomeMy WebLinkAboutENERGY EFFICIENCY CODEANE
FORM R405-2017 St Lu
FLORIDA ENERGY EFFICIEN,
Florida Department of Business and P
E FOR BUILDING CONSTRUCTION
nal Regulation - Residential Performance Method
Project Name: WYNNE THE WINDSOR IMPACT
SC
Builder Name: WYNNE DEVELOPMENT
NNED
Street: THE WINDSOR
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
BY Permit Number:
E
Owner: �u
ie coun4itfrisdiction:
Design Location: FL, Fort Pierce
?Ounty:: St. Lucie (Florida Climate Zone 2
1. New construction or existing New (From Plans)
9. Wall Types(1432.0 sqft.) Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior R--4.1 1224.00 ft2
b. Frame - Wood, Adjacent R=1 1.0 208.00 ft2
3. Number of units, if multiple family 1
c. N/A R= ft2
4. Number of Bedrooms 3
d. N/A R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1753.0 sqft.) Insulation Area
a. Under Attic (Vented) R=30.0 1753.00 ft2
6. Conditioned floor area above grade (ft2) 1753
b. N/A R= ft2
Conditioned floor area below grade (fl:2) 0
c. N/A R= ft2
11. Ducts R ft2
7. Windows(151.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic 6 225
a. U-Factor: SgI, U=0.63 111.36 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65 40.00 ft2
12. Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit 34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump 34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 0.239
14. Hot water systems
a. Electric Cap: 40 gallons
8. FloorTypes (1753.0 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits Pstat
Total Proposed I �Iodified Loads: 53.83
Glass/Floor Area: 0.086 I PASS
Total Baseline
Loads: 53.85
1 her6by certify that the plans and specifications covered by
Review of the plans and If 114E Sr
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
n,,
with the Florida Energy Code.
IPRE'PAR..
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in comp iance
Florida Statutes.
with the Florida Energy Code.
'n WF'
OWNERg/��
BUILDING OFFICIAL:
DATE:
DATE:
I
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.1
- Compliance requires an Air Barrier and Insulation Insp I ection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
a
4/16/2018 8:46 PM EnergyGauge@ USA - FI Res2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
PROJECT
Tifle: WYNNE THE WINDSOR IM Bedrooms
3
Address Type:
Street Address
Building Type: User Conditioned
Area: 1753
Lot #
Owner Name: Total Stori
I as: 1
Block/Subdivision:
# of Units: I Worst Case:
Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate
225
Street:
THE WINDSOR
2le.
Permit Office: ST. LUCIE COUNTY Cross Ve
t
tilation: No
County:
St. Lucie
io
Jurisdiction: Whole Ho
se Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
V
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location TMY Site
97.5% 2.5%
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL—VERO—BEACH—MUNI
39 90
70
75
299
62
Low
I BLOCKS
Number Name Area Volumel
1
1 Entire House 1753 14024
SPACES
Number Name Area Volume
lKitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
I MASTER BEDROO 224 1792
No 0
1
1
Yes
Yes
Yes
2 WIC 63 504
No 0
1
No
Yes
Yes
3 MASTER BATH 56 448
No 0
1
Yes
Yes
Yes
4 M. BATH 61 488
No 0
1
Yes
Yes
Yes
5 LAUDRY 36 288
No 0
1
No
Yes
Yes
6 BEDROOM 2 180 1440
No 0
1
1
Yes
Yes
Yes
7 DINING/GREAT R 588 4704
No 2
1
Yes
Yes
Yes
8 KITCHEN 209 1672
Yes 0
1
Yes
Yes
Yes
9 BATH 50 400
No 0
1
Yes
Yes
Yes
10 HALL 25 200
No 0
1
No
Yes
Yes
11 FOYER 92 736
No 0
1
Yes
Yes
Yes
12 BEDROOM 3 169 1352
No 0
1
1
Yes
Yes
Yes
FLOORS
V# Floor Type Space Perimeter
Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
I Slab -On -Grade Edge Insulatio MASTER BEDRO 3-1
ft 0
224 ft2
----
0 1
0
2SIab-On-Grade Edge Insulatio WIC I
ft 0
63 ft2
----
0 1
0
3 Slab -On -Grade Edge Insulatio MASTER BATH 8
ft 0
56 ft2
----
0 1
0
4 Slab -On -Grade Edge Insulatio M. BATH 7
ft 0
61 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulatio LAUDRY 1
ft 0
36 ft2
----
0 1
0
4/16/2018 8:46 PM EnergyGauge@ USA - FIaRes2017
Section R405.4.1 Compliant Software
Page 2 of 5
FORM R405-2017
FLOORS
y#
Floor Type
Space Perimeter
Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12
ft
0
180 ft2
----
0
1
0
7 Slab -On -Grade Edge Insulatio
DINING/GREAT 50
ft
0
588 ft2
----
0
1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN 11
ft
0
209 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio
BATH
5 ft
0
50 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio
HALL
1 ft
0
25 ft2
----
0
1
0
1 1SIab-On-Grade Edge Insulatio
FOYER
9 ft
0
92 ft2
----
0
1
0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 1
ft
0
169 ft2
----
0
1
0
ROOF
Roo
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
# Type Materials Are
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Gable or Shed
Metal 164 t TV
292 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V#
Type
Ventilation
Vent Ratio (I in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
V#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented)
MASTER BEII I
RO
30
Blown
224 ft2
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 ft2
0.1
Wood
6 Under Attic (Vented)
BEDROOM
2
30
Blown
180 ft2
0.1
Wood
7 Under Attic (Vented)
DINING/GRE AT
30
Blown
588 ft2
0.1
Wood
8 Under Attic (Vented)
I
KITCHEN
30
Blown
209 ft2
0.1
Wood
9 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
10 Under Attic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM
3
30
Blown
169 ft2
0.1
Wood
WALLS
#
Adjacent
Ornt In Wall lype
Space
Cavity Width
R--Vahle Ff In
Height
Et In
Area
Sheathing Framing
R-\Inl,le Eractoon
Solar
Ahqor
Below
Grarle%
I
NE=>W Exterior Concrete Block - Ext InaMASTER BE
4.1 16
0 8
0
128.0 ft2
0
0
0.5
0
2
1
SW=>E Exterior Concrete Block - Ext In9MAS1 ER BE
4.1 7
0 8
0
56.0 ft2
0
0
0.5
0
3
1
NW=>S Exterior Concrete Block - Ext InsMAS1 ER BE
1
4.1 14
0 8
0
11200 ft2
0
0
0.5
0
4
NE=>W Exterior Concrete Block - Ext In9hAAS1 ERbA
1
4ol 8
0 8
0
64.0 ft2
0
0
0.5
0
4/16/2018 8:46 PM EnergyGauge@) USA - F IaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017
I WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar Below
)lar Belod
Ornt 10
Wall Tvpe Space
R--Val-le Et In
Et In
Area
R-Val-le
Ernctffion Ah
5
NE=>W Exterior
Concrete Block - Ext InsulM. BATH
4.1 7
0
8 0
56.0 ft2
0
0
0.5
0
.6
NE=>W Exterior
Concrete Block - Ext InEEDROOM
2 4.1 12
0
8 0
96.0 ft2
0
0
0.5
0
7
SW=>E Exterior
Concrete Block - Ext IndXNING/GRE
- 4.1 30
0
8 0
240.0 ft2
0
0
0.5
0
8
NW=>S Exterior
Concrete Block - Ext IndANING/GRE
- 4.1 20
0
8 0
160.0 ft2
0
0
0.5
0
9
SW=>E Exterior
Concrete Block - Ext InsuKITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.5
0
10
NE=>W Exterior
Concrete Block - Ext Insul BATH
4.1 5
0
8 0
40.0 ft2
0
0
0.5
0
11
SE=>N Exterior
Concrete Block - Ext Insul FOYER
4.1 8
0
8 0
64.0 ft2
0
0
0.5
0
12
SW=>E Exterior
Concrete Block - Ext Insul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.5
0
13
NE=>W Exterior
Concrete Block - Ext IndMDROOM
3 4.1 13
0
8 0
104.0 ft2
0
0
0.5
0
14
SW=>E Exterior
Concrete Block - Ext In!EEDROOM
4.1 1
0
8 0
8.0 ft2
0
0
0.5
0
15
N=>SW Garage
Frame - Wood BEDROOM
3 11 26
8
208.0 ft2
0.23
0.5
0
DOORS
V#
Ornt
DoorType Space
Storms
I
U-Value
Width
Height
Area
Ft
In
Ft In
I SE=>N Insulated FOYER
I None
.39
3
3
6 8
21.7 ft2
WINDOWS
4tered
Orientation shown is the
orientation (=>) changed to Worst Case.
V-
Wall
�U-Factor
Overhang
# Ornt ID
Frame Panes NFRC
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 NW=>S 3
Metal Low-E Single Yes
0.63 0.25
N
32.4 ft2
1 ft 0 in
I ft 4 in
Drapes/blinds
Exterior 5
2 NE=>W 5
Metal Low-E Single Yes
0.63 0.25
N
6.9 ft2
1 ft 0 in
1 ft4 in
None
None
3 NE=>W 6
Metal Low-E Single Yes
0.63 0.25
N
16.2 ft2
1 ft 0 in
1 ft4 in
None
None
4 SW=>E 7
Metal Low-E Single Yes
0.63 0.25
N
39.8 ft2
1 ft 0 in
1 ft 4 in
None
None
5 NW=>S 8
Metal Low-E Single Yes
0.65 0.21
N
40.0 ft2
8 ft 0 in
1 ft 4 in
None
None
6 NE=>W 13
Metal Low-E Single Yes
0.63 0.25
N
16.2 ft2
1 ftO in
I ft4 in
Drapes/blinds
Exterior 5
GARAGE
V#
Floor Area Ceiling Area lExposed
Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 806 ft2 806 ft2
26 ft
8 ft
1
INFILTRATION
# Scope Method SLA C FM
1
50 ELA
EqLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356 1'636.1
89.82
168.92
.2598
7
4/16/2018 8:46 PM EnergyGauge@ USA - F, IaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
kATING
SYSTEM
y #
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/
Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
c60LING
SYSTEM
y #
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.85
1
sys#1
HO�
WATER SYSTEM
I
y#
System Type
SubType
Location
�F Cap Use
SetPnt
Conservation
1
Electric
None
Garage
97 40 gal 60.9 gal
120 deg
None
SOLAR
�OT WATER SYSTEM
VFSEC
Cert # Company Name
System
Collector
Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
V #
Supply
Location R-Value Area
Return
Location Area
Leakage Type
Air
Han . dler
CFM 25
TOT
CFM25
OUT
QN
RLF
HVAC #
Heat Cool
1
Attic
6 225 ft2
Attic
60
ft2 Default Leakage
Attic
(Default)
(Default)
1 1
#MPERATURES
Prograrnable, Thermostat: Y
Cooling Jan Feb
He Jan Feb
Ve Jan Feb
Mar
X Mar
Mar
Ceiling
Aprr May
A may
Apr may
I
Fans:
Jun Jul
Jun Jul
rl Jun ri Jul
Aug
Aug
ri Aug
Sep
Sep
�I Sep
Oct
Oct
Oct
Nov
X Nov
Nov
Dec
Dec
Dec
Thermostat Schedule: HERS 2006 Reference
Schedule Type 1
2 3
Hours
4 5 6 7
8
9
10
11
—
12
Cooling (WD)
Cooling (WEH)
Heating (WD)
Heating (WEH)
AM
PM
AM
PM
AM
PM
AM
PM
78
80
78
78
66
68
66
68
78 78
80 78
78 78
78 78
66 66
68 68
66 66
68 68
78 78 78
78 78 78
78 78 78
78 78 78
66 66 68
68 68 68
66 66 68
68 68 68
78
78
78
78
68
68
68
68
78
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
66
68
66
80
78
78
78
68
66
68
66
4/16/2018 8:46 PM EnergyGauge(D USA - FlIes2017 Section R405.4.1 Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPEC I ION COMPONENT CRITERIA
I
TABLE 402.4.1.1
AIR BARRIER AND INSULAT iON INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT
Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CR,ITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed
The exterior thermal envelope contains
in the building envelope.
a' continuous air barrier.
Air -permeable insulation shall
requirements
Breaks or joints in the air barrier shall b�
sealed.
not be used as a sealing material.
Ceiling/affic
The air barrier in any dropped ceiling/soffit
the insulation and any gaps in the air ba
I
shall be aligned with
I rrier shall be sealed.
The insulation in any dropped ceiling/soffit
shall be aligned with the air barrier.
Access openings, drop down stairs or kre
wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plalte
shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top
of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambsi
and framing, and
and doors
skylights and framing shall be sealed.
I
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any
el xposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl space
s shall be covered with
Where provided instead of floor insulation, insulation
I
a Class I vapor retarder with overlapping
joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and fluel
shafts opening to
exterior or unconditioned space shall b el
sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between t I ke
garage and conditioned spac
Ds.
Recessed lighting
I
Recessed light fixtures installed in the building
thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring,
Shower/tub
The air barrier installed at exterior walls
adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the sho�vers
and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behin�
electrical or communication
exterior walls
boxes or air -sealed boxes shall be installied.
HVAC register boots
HVAC register boots that penetrate building
thermal envelope shall
be sealed to the sub -floor or drywall. I
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommend ed by the manufacturer.
Caulking or other adhesive sealants s6l not be used to fill voids
I
between fire sprinkler cover plates and walls or ceilings -
a. in addition, inspection of log walls shall be in accordance wit� tne provisions of ICC-400.
4/16/2018 8:46 PM EnergyGauge@) USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of I
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerfo �Imance Index, the more efficient the home.
1 . New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (fl:2)
7. Windows- Description
a. U-Factor: Sgl, U=0.63
SHGC: SHGC=0.25
b. U-Factor: SgI, U=0.65
SHGC: SHGC=0.21
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
THE W1
New (From Plans)
Single-family
1
3
Yes
1753
Area
111.36 fl:2
40.00 ft2
ft2
ft2
2.850 ft.
0.239
Insulation
Area
R=0.0
1753.00 ft2
R=
ft2
R=
ft2
FT. PIERCE, FL,
9. Wall Types
a. Concrete Block - Ext Insul, Exterior
b. Frame - Wood, Adjacent
c. N/A
d. N/A
10. Ceiling Types
a. Under Attic (Vented)
b. N/A
c. N/A
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
12. Cooling systems
a. Central Unit
13. Heating systems
a. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new E L Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Date:
Address of New HomeNCL191 NN City/FL Zip7ZZIc�.\,_ e;;�,v
Insulation
Area
R=4.1
1224.00 ft2
R=1 1.0
208.00 ft2
R=
ft2
R=
ft2
Insulation
Area
R=30.0
1753.00 ft2
R=
ft2
R=
ft2
R ft2
6 225
kBtu/hr Efficiency
34.8 SEER:15.00
kBtu/hr Efficiency
34.8 HSPF:8.50
Cap: 40 gallons
EF: 0.97
.04E S
16.
WE
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida En I 6rgyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Bul ilding Code, Energy Conservation, contact the Florida Building
Commission's support staff. 1.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1
4/16/2018 8:46 PM EnergyGauge@ USA - FlaRes2017 - Section R405.4.1 Compliant Software
Page 1 of 1