RE: M1 1323 - 62'Grand Carlton III with porch
Site Information:
Customer Info: WYNNNE DEVELOPEMENT COR
Lot/Block: Subdivi!
Address: N/A
City: PORT ST LUCIE State: F
Name Address and License # of Structural Engi
Name:
Address:
City:
General Truss Engineering Criteria & Design
Loading Conditions):
Design Code: FBC2017/TPI2014
Wind Code: ASCE 7-10
Roof Load: 37.0 psf
This package includes 13 individual, dated Truss D(
With my seal affixed to this sheet, I'hereby certify th
conforms to 61 G 15-31.003, section 5 of the Florida
No.
Seal#
ie
1
T133023S
:_Date
12
2
T1 33023911
A5
2/21/18
13
1 T1 3302392
1 A6
12/21/18
14
IT13302393IA7
L2alLl 8 J
15
1 T1 3302394
1 A8
12/21/18 1
16
1 T1 3302395 1
A9
12/21/18 1
17
T133023961GRA
12/21/18_
J
[��_
T13302397 I
GRB 1
/21/18
19 JT13�0239�JJ2
12/21/18
110 IT13302399
J4_L?11/18_j
Ill IT13302400IJ6
12/21/18
1
112 IT13302401IJ8
12/21/18
11 3_1
T1 33024 2
LKJ8 _I
2/2 1 /18
The truss drawing(s) referenced above have been prep
USA,.Inc. under my direct supervision based on the p,
provided by Chambers Truss.
Truss Design Engineer's Name: Albani, Thomas
My license renewal date for the state of Florida is Fet
IMPORTANT NOTE: The seal on these truss component desii
that the engineer named is licensed in the jurisdiction(s) identified and
designs comply with ANSI/TPI 1. These designs are based upon pare
shown (e.g., loads, supports, dimensions, shapes and design codes),
given to MiTek. Any project specific information included is for M!Tek
file reference purpose only, and was not taken into account in the prep
these designs. MiTek has not independently verified the applicability
parameters or the designs for any particular building. Before use, the
should verify applicability of design parameters and properly incorp6ra
into the overall building design per ANSI/TPI 1, Chapter 2.
values arcrin accordance with ANSI/TPI 1 section 6.3
,ign
s re.1y on lumber values established by others.
MiTek USA, Inc.
6904 Parke East Blvd.
T, y, 5�Y610-4115
Project Name: M1 1323 Model'-.�p
on:
er of Record, If there is one, for the building.
License #:
State:
(individual Truss Design Drawings Show Special
-sign Program: MjTek 20/20 8.1
ind Speed: .165 mph
oor Load: N/A psf
gn Drawings and 0 Additional Drawings.
I am the Truss Design Engineer and this index sheet
,ard of Professional Engineers Rules.
by MiTek
28,2019.
is a certification
t the
/nicn were
; customers
iration of
the design
uilding designer
, these designs
Ilk
0
93 0
*QJ
STATE OF
%
Thomas A. Albanl PE No.39380
Mak USA, Inc. FL Cent 6634
699 Parke East Blvd.11ampa Fl. 33610
Date:
February 21,2018
Albani, Thomas 1 of 1
Job
Truss
Truss Type
Qty
Ply
62'Grand Carlton III with porch
T13302390:
M11323
A
COMMON
�1�r e r
_' i A 4 ; i W A C k 01 4A 4n �q �A!Q an n 1
Chambers Truss, inc.,
ruri r-ielutp, rL
. i S �ap I � — i i M. " u� !' " . U
I D:a3B4PavKnnZweXyJckSFBgyuFUN-iltla6GS6xdm-lTrGI?GZC-lGrGmYZaVXI 111 xziuKK
�6 11 �3
1
1
-0-0
1 21-7-3 Z7 4 3 34-0-0 5-0-
1
�11 Voo
�4-13
—7-3
—
I i -7-13 -o-n
4-7-3 6 1
Scale 1:57.8
4.00 ri _2
4x5
6 27
2x3 11 25
26
28 2x3
3x6
5
7 3x6
3x4 7::�
4
3x4
3
7
9
i
24
29
2
10 11
9
E12
_fzza �
6 E�
1�2 6
17
16
15
30 31 14 13 12
2X3 11
4x6 3X8
3X8 46 2X3 11 3x6
3x6
�6_-7113�
12-4-13
21-7-3 �7-4 3 34-0-0
5-9-0
—4
9-2-7 6-7-13
Plate Offsets (X,Y)--
[2:0-0-2,Edgel, [10:0-0-2,Edq 1
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL. in (loc) I/defl Ud
PLATES GRIP
TOLL 20.0
Plate Grip DOL
1.25
TO 0.39
Vert(LL) 0.32 14-15 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.58
Vert(CT) -0.61 14-15 >670 240
BOLL 0.0
Rep Stress Incr
YES
WB 0.65
Horz(CT) 0.12 10 n/a n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MS
Weight: 163 lb FT=O%
LUIMBER-
BRACING-
TOPCHORD 2x4 SP M 30
TOPCHORD Structural wood sheathing directly applied or 3-7-12 oc purlins.
BOTCHORD 2x4 SP M 30
BOTCHORD Rigid ceiling directly applied or 4-11-7 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=1362/0-8-0, 10=1362/0-8-0
Max Harz 2=-1 79(LC 8)
Max Uplift 2=-832(LC 10), 10=-832(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when hown.
TOPCHORD 2-3=-341912395, 3-5=-2771/2031, 5-6=-2770/2152, 6-7=-2770/2 52, 7-9=-2771/2031,
9-10=-3419/2395 I
BOTCHORD 2-17=-2132/3213,15-17=-2132/3213,14-15=-1269/2000,12-14--213213213,
10-12=-2132-/3213
WEBS 6-14=-635/983, 7-14=-313/362, 9-14=-689/49916-15=-635/983, 15=-313/362,
3-15=-689/499 i-
NOTES-
I ) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; VuIt=1 65mph (3-second gust) Vasd=1 28mph; TCDL=4.2psfl BCDL=3.Opsf; h=1 4ft; B--52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional), and C-C Exterlor(2) -1-0-0 to �-4-13, Interion(l) 2-4-13 to 13-7-3, Exterlor(2) 13-7-3
to 17-0-0, Interior(l) 20-4-13 to 31-7-3 zone;C-0 for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60 1
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrept with any other live loads.
4) * This truss has been designed for a live load of 20.Opsf an the bottom chord in W areas where a rectangle 3-6-0 tall by 2-0-0 wide
Will fit between the bottom chord and any other members, with BCDL -- 10.Opsf. I
5) Provide mechanical connection (by others) of truss to bearing plate capable of �lithstandlng 100 lb uplift at joInt(s) except Ot=lb)
2=832,10=832. 1
6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 50 lb down and 47 lb up at
15-0-0, and 50 lb down and 47 lb up at 19-0-0 on top chord. -The design/selecti6n of such connection device(s) is the responsibility
of others. I
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
k
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber lncrease=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-6=-54, 6-11 =-54, 18-21 �20
Concentrated Loads (lb)
Vert: 26=-50(F) 27=-50(F)
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
,&WARNING -Verify design pamrnetersandRE4D NOTES ON THIS AND INCLUDEDifirEKnEFERANCE PAGE MY-7473,.. 10)V312015 BEFORE USE
Design valid for use only with MITek(b) connectors. This design Is based only upon parameter , r shown, and Is for an Individual building component, not
Et
a truss system. Before use, the building designer must verify the applicability of design palahieters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTel(
Is always required for stability and to prevent collapse with possible personal Injury and pro�erly damage. For general guidance regarding the
fabdcallom storage, delivery, erection and bracing of trusses and truss systems_ seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Adexandda, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Carlton III with porch
T13302391
M1 1323
A6
SPECIAL
9.
E'Grand
Job Reference (optional)
(zarriners I russ, I nc., ron: vierce, r-L
7-8-5
6-5-12
4.00FI-2
2X3 11
5x6 WB--
5 5
2X3 Z�- 4
3
21
14
2
5xi 2 IVT1 8HS
3x12 �� 2.00FI-2
22
ID:2GIScwwyY5hnGhXVARzUkuyuFUM-BURgnSH4tF]dcR2lqTWR6QXpvFX-HlUfmhlbZNziuKJ
26-4-0 34-0-0
5-11-8 i 7-8-0 V
5X8 II
6
2x3 11
7
3x6
8 3x4
9
23
13 12
5x12 2x3
5-4-0 34-0-0
1-9 1 7-8-0
Scale = 1:59.8
10 it
6
3X6 =
LOADING (psf)
SPACING-
2-0-0
CS1.
DIEFL.
in (loc)
I/defl
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.85
Vert(LL)
0.76 14
>539
360.
MT20
244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.90
Vert(CT)
-1.18 13-14
>344
240
MT18HS
244/190
BCLL 0.0
Rep Stress [nor
YES
WB 0.60
Horz(CT)
0.36 10
n1a
n/a
BCDL 10.0
Code FBC2017fTP]2014
Matrix -MS
Weight: 155 lb
FT = 0%
LIUMBER- BRACING-
TOPCHORD 2X4 SP M 30 TOPCHORD
BOTCHORD 2X4 SP M 30 BOTCHORD
WEBS 2x4 SP No.3 *Except* WEBS
6-14: 2x4 S P M 30
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 2=1312/0-8-0, 10=1312/0-8-0
Max Horz 2=-1 79(LC 8)
Max Uplift 2=-803(LC 10), 10=-803(LC 10)
FORCES. (b) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when sh ' Lwn.
TOPCHORD 2-3=-5529/3776, 3-5=-51 64/3538, 5-6=-5209/3667, 6-7=-2424/1902, 7-9=-2462/1813,
9-1 0=-3195/221 0 1
BOTCHORD 2-14=-3466/5266, 13-14=- 1305/2115, 12-13=- 1948/2995 ' 10-12=4948/2995
WEBS 3-14=-355/314, 6-14=-293/354, 6-14=-2175/3326, 6-13=-279/534, 7-13=-2371277,
9-13=-786/560, 9-12=0/269
Structural wood sheathing directly applied or 1-7-8 oc pudins.
Rigid coiling directly applied or 3-9-12 oc bracing.
I RovVat midpt 6-14
NOTES-
1 ) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=1 28mph; TCDL.=4.2psf; CDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 214-13, Interior(l) 2-4-13 to 13-7-3, Exterlor(2) 13-7-3
to 17-0-0, Interlor(l) 20-6-4 to 31-7-3 zone;C-C for members and forces & MWFRS for reactions shown; Lumber,DOL=1.60 plate
grip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurreJ with any other live loads.
5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in a6 areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members. 1
6) Bearing at joint(s) 2 considers parallel to grain value using ANSIfTP1 1 angle to grain formula. Building designer should verify
capacity of bearing surface. I '
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb)
2=803,10=803.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
,& WARNING- Verify destgn parameters and READ NOTES ON THISANDINCLUDED MITEKREFE RIANCE PAGE M11-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with Mffek(D connectors. This design Is based only upon parameters'shown, and Is for an Individual building component. not
a truss syttem. Before use, the building designer must verify the applicability of design pararrieters
and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord
members only. Additional temporary and permanent bracing
'
MOW
ury or(
Is always required for stability and to prevent collapse with possible personal Inj d p
rty damage. For general guidance regarding the
fabrication, storage, delivery. erection and bracing of trusses and truss system% seeANS
Ity ,
Qual criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Instfitute, 218 N. Lee Street Suite 312, PJexar/vd;d,7-,iVA
22,14.
Tampa, FIL 33610
Job
Truss
Truss Type
City
Ply
62'Grand Carlton III with porch
T13302392
M11323
A6
SPECIAL
Job Reference (optional)
A40 0 4
Ghamners I russ, Inc.,
Fort Pierce, FL
0.! OUS oup 1 u �v! 1 1V11 I GNMIGLisirlas, r1c. G
ID:2GIScwwyY5hnGhXVARzUkuyuFUM-fh-3?olieYtUEbdENAI
gfd4?AftlOQoo_Ln86qziuKI
8-11-11
16-0-0
18-0-0 1 L048
�5-11 15
34-0-0
8-11-11
7-0-5
2-0-0
57
8-0 -1
Scale 1:61.9
4. 0 0 Ff2— t)XZS
— 5x6
5 6
W
3x4
5x6 VVB��
5x6 WB--
34
7 8
21
22
2.
14
9 10
5x1 2 IVITI 8HS
13
6
3x4 Zz
12
11
Gx6
2x3 11
M
3x12
2.00 F1 —2
10-6-4
15-0 6-10-
048
2%.171.�l 5
9A -0-0
10-6-4
� __�2
2 1_01
4
8-0-11�
Plate Offsets (X,Y)--
[2:0-1-15,Edgel,[3:0-3-0,Edgel,[5:0-4-0,0-2-31,[7:0-2-7,Eddel,i9:0-0-6,EdgeI
LOADING (pst)
SPACING- 2-0-0
CS1.
DEFL.
in (loc) I/defl
Ud
PLATES
GRIP
TOLL 20.0
Plate Grip DOL 1.25
TO 0.81
Vert(LL)
0.69 14 >590
360
N�120
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.93
Vert(CT)
-0.92 14-17 >443
240
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.86
Horz(CT)
0.34 9 n/a
n1a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 157 lb
FT'-- 0%
LIUMBER-
TOPCHORD
2X4 SP M 30 *Except'
3-5,6-7: 2X4 S P M 31
BOTCHORD
2x4 SP M 30
WEBS
2x4 SP No.3 *Except*
5-14: 2x4 S P M 30
OTHERS
2x4 SP No.3
REACTIONS. (Ib/sIze) 2=1312/0-8-0,9=1312/0-8-0
Max Harz 2=-1 69(LC 8)
Max Uplift 2=-803(LC 10), 9=-803(LC 10)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when sh
TOPCHORD 2-4=-5491/3336, 4-5=-5095/3071, 5-6=-2314/1551, 6-8=-23981115�
BOTCHORD 2-14=-3040/5224,13-14=-1 195/2361, 12-13=-1 123/2199,11-12=-
9-11 =-1 731/3001
WEBS 4-14=-492/513, 5-14=-1 707/2959, 5-13=-405/19.6, 6-13=-1 79/522,
8-11 =0/303
BRACING-
TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc puffins.
BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
8-9=-3199/1981
31/300.1,
12=-893/660,
NOTES-
1 ) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psI; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; Exp, C; Encl., GCpi=O.l 8; MWFRS (directional) and C-C Exterior(2) -1 -0-0 to 21,4-13, Interlor(l) 2-4-13 to 31-7-3, Exterlor(2) 31-7-3
to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water poncling.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent� with any other live loads.
6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members. I
7) Bearing at Joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface. I
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
2=803,9=803.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FIL Cart 6634
0904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
A& WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED M11EAREFERANCEPAGEM11-7473 rev. IaIO3)2015 BEFORE USE.
Design valid for use only with M]Tek(D connectors. This design Is based only upon parameters shown, and Is for an Individual building component riot
a truss system. Before use. the building designer must verify the applicability of design pararnefers and properly incorporate this design Into the overall
buildnig design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSI/TPI I Quallity Criteria, DSB-89 and BCS1 Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Street Suite 312, Alexanclfla,,VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
62'Grand Carlton III with porch
T13302393
M11323
A7
SPECIAL
1.
Job Reference (optional)
Chambers I russ, Inc.,
Fort Pierce, FL
S. i30 5 Sep 15 2017 rvit i eK muubffleb,
MU. Vveu rew � 1 I—. — 1. 1 U. i
G
ID:WSJqpGwa[Ppeur6hkgUjG5yuFUL-7tYRC�JLPsOLrICQxuZvBrcAj DQIsZxD?WieGziuKH
B-10-10
14-0-0
20-0-0
L5-111 5
34-0-0
:�5-0-Q
�10040
8-10-10
5-1-6
6-0-0
5_11. �15
8-0-1
4-0-01
Scale 1:60.8
5XB
W
4.00 [1-2
4
5
r
2X3
L
3x4 z::�
3
6
t2
19
2
��a
7 8
5x12 MT1 BHS
9
]��
6
10
9
6
5x12
2x3 11
3X6
W2
2.00F1-2
10-6-4
0-4-8
L&4�'
25-11-15
34-0-0
10-6-4
0
A%
5-7-7
8-0-1
Plate Offsets (X,Y)--
f2:0-1 -15, Edge], [4:0-4-0,0-2-3], [7:0-0-2, Edge]
LOADING (psf)
SPACING-
2-0-0
CS11.
DEFL. in (loc) Weil
Ud
PLATES
GRIP
TCLIL 20.0
Plate Grip DOL
1.25
TC . 0.83
Vert(ILL) 0.66 11 >616
360
MT20
244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.90
Vert(CT) -1.10 10-11 >369
240
MT18HS
244/190
BCLL 0.0
Rep Stress Incr
YES
WEI 0.95
Horz(CT) 0.34 7 n1a
n/a
BCDIL 10.0
Code FBC2017[-FP12014
Matrix -MS
Weight: 147 lb
FT = 0%
LIUMIBER-
TOP CHORD
2X4 SP M 30
BOT CHORD
2X4 SP M 30
WEBS
2x4 SP No.3 *Except*
4-11: 2x4 SP M 30
BRACING-
TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc puffins.
BOTCHORD Rigid ceiling directly applied or 4-0-2 oc bracing.
REACTIONS. (Iblsize) 2=1312/0-8-0,7=1312/0-8-0
Max Horz- 2=-149(LC 8)
Max Uplift 2=-803(LC 10), 7=-803(LC 10)
FORCES. (b) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when sh, wn.
TOPCHORD 2-3=-5484/3370, 3-4=-5116/3126, 4-5=-2229/1544, 5-6=-2448/15R9, 6-7=-3169/1993
BOTCHORD 2-11 =-3071/521 9, 10-11 =- 1590/2874, 9-1 0=- 1738/2968, 7-9=- 1 73P/2968
WEBS 3-11 �41 9/443, 4-11 =- 1466/2647, 4-1 0=- 812/448, 5-1 0=-205/487,16-1 0=-785/575,
6-9=0/272
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2),Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.ZPST; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterlor(2) -1-0-0 to 214-13, Interion(l) 2-4-13 to 31-7-3, Exterjor(2) 31-7-3
to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=11.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent, with any other live loads.
6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members. 1
7) Bearing at Joint(s) 2 considers parallel to grain value using ANSIfTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface. 1
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
2=80317=803. 1
Thomas A. Albani PE No.39380
MiTsk USA, Inc. FIL Cert 8634
6904 Parke East Blvd. Tampa FL $3610
Date:
February 21,2018
,& WA RNING - Verify des Ign para m & I ers an d REA D NO TES 0 N THIS A ND INC L UDED mrr.-K REFERAl
NCE PA G E M11. 74 73 re v. 1 OM12015 B EFO R E US E.
Design valld for use only with MITekO connectors. This design Is based only upon parameters'shown,
and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applIcab4llty of design pararrieters,
and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord
members only. Additional temporary and permanent bracing
WeIC
is always required for stability and to prevent collapse with possible personal Injury and prop6rty
damage. For general guidance regarding the
fabrication, storage, delivery. erection and bracing of trusses and truss systems. seeANSI/TPI I
Quallty Criteria, DSB-89 and BCS] Building Component
6904 Parke East Blvd.
Safety information available from Truss Plate Institute. 218 N. Lee Street Suite 312. Aexandda,'
VA 22314.
Tampa, FIL 33610
Job
Truss
Truss Type
city
Ply
62'Grand Carlton III with porch
T13302394
M11323
AB
SPECIAL
1.
1
Job Reference (optional)
unamDers I russ, mc., rori merce, r-L .. . — . —F . . — , , — . � . I .. . ..' .— . . .
ID:WSJqpGwaIPpeur6hkgUjG5yuFUL-b36pQTKzAASCTvncVb48k2gLBTZgUMw5SfGFAiziuKG
8-8-4 5-11-4 20-4-8 L2 41- 2 34-0-0 �.5-0-
0 -001 1 -3-4
4-101 8-8-4 138-4 11 4-8-4 7-� 2 .112 9
Scale = 1:60.6
5X6
2x3 11 5x8
4.00 FIT 4 2`1
6 22 7 2X3
2X3 Z�'
8
3
20
23
13
2
5x1 2 IVITI 8HS
10
6
6
12 11
5x12 3x4 4x6
3x'12 2.00 F1 _2
10-6-4 20-41-8
L2 10 34-0-0
10-6-4 �-14
1 12-0-0
Plate Offsets (X,Y)-- [2:0-1-15,Edgel, [7:0-5-8,0-2-81
1
LOADING (pst)
SPACING-
CS1.
DEFL. in (loc) Well Ud
PLATES GRIP
TCLL 20.0
.2-0-0
Plate Grip DOL 1.25
TC 0.78
Vert(LL) 0.65 12-13 >624 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.90
Vert(CT) -1.08 12-13 >379 240
MT18HS 244/190
BCLIL 0.0
Rep Stress Incr YES
WB 0.69
Horz(CT) 0.33 9 n/a n1a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 154 lb FT = 0%
LUMBER-
BRACING-
TOPCHORD 2x4 SP M 30
TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc purlins.
BOTCHORD 2x4 SP M 30
BOTCHORD Rigid ceiling directly applied or 3-11 -11 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=1312/0-8-0, 9=1312/0-8-0
Max Horz 2=-1 29(LC 8)
Max Uplift 2=-803(LC 10), 9=-803(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when
W.
n6-7=-2,,6/1779,
TOPCHORD 2-3=-6488/3444, 3-4=-5117/3183, 4-5=-3911/2497, 5-6=-2576/4t,
7-8=-2663/1762, 8-9=-3021/1971
BOTCHORD 2-13=-3143/5224,12-13=-1 956/3292, 11-12=-1 369/2481, 9-11 =-1
05/2827
WEBS 3-13=-396/420, 4-13=-1 028/1721, 5-13=-3001797, 5-12=-894/601,
6-12=-2651263,
7-12=-294/391, 7-11 =-3741691, 8-11 =-535/502
NOTES-
1 ) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=14ft; B=52ft; L=34ft; eave-6ft; Cat.
11; Exp Q Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 4. 4-13, Interior(l) 2-4-13 to 31-7-3, Exterior(2) 31-7-3
to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise Indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenj with any other live loads.
6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members. 1
7) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI I angle to grain formula. Building designer should verify
capacity of bearing surface. 1
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
2=803,9=803.
Thomas A. Albani PIE No.39380
MiTek USA, Inc. FIL Cort 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
AQ, WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERIANCE PAGEMII-7473 rev. 10.(03,2015 BEFORE USE.
Design valid for use orgy with MITeW connectors. This design'ls based only upon parameters � shown, and Is for an Individual building component. not
a truss system. Before use. the building designer must verify the applicability of design paror�eters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chor� members only. Additional temporary and permanent brming
MiTek*
Is always required for stability and to prevent collapse wilh possible personal Injury and propbrly damage. For general guidance regarding the
fabrication. storage, delivery; erection and bracing of trusses and truss systems. seeANSI/TpI I� Quality Criteria, DSO-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandrim VA 22,314.
Tampa, FL 33610
Job
Truss
rruss Type
�Q�tyPly
2'Grand Carlton III with porch
T13302395
M11323
Ag
HIP
1.
1
1
1
'�6
b R f ce (optional)
-
— -
.1 ' 1-1 ... — M�A E�h o4 4A.in a onip r)ann 1
L,namDer5 i iuss, niu., rUl L rIU16U, —
4.00F1_2
2x3
3
2 3_��
c�. 22
2
3X5
ID:-etClcxC3ixVV?huls?ypJyuFUK-3FgBdpKbwTG353Mp3jbNGGidcs?ZDm3EgJ?oj8ziuKF
15-2-14 20-4-0 24-0-0 27-4-1 34-0-0
i-O i
3- Vio 5-2-14 6-1-2 3-8-0 3-4-1 6-7-15
Scale 1:58.6
4x4 3x 2x3 11 4x8
4 24 l525 26 6 27 7
2x3 5'-
28
29
9 10 1�
6
6
15 14
3x8 � 3X6
13 12 1`1
6X8 = 3X6 = 3x4
3x5 --
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in (loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.35
Vert(LL) -0.18 11-21 >917 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.54
Vert(CT) -0.38 11-21 >432 240
BCLL 0.0
Rep Stress Incr YES
WB 0.89
Horz(CT) 0.02 13 n1a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 156 lb FT=O%
LUMBER- BRACING-
TOPCHORD 2X4 SP M 30 TOPCHORID
BOTCHORD 2X4 SP M 30 BOTCHORD
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=663/0-8-0,9=34610-8-0,13=161610-8-0
Max Harz 2=1 09(LC 9)
Max Uplift 2=-430(LC 10), 9=-249(LC 10), 13=-928(LC 10)
Max Grav 2=685(LC 19), 9=386(LC 20),13=1616(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (1b) or less except when shown.
TOPCHORD 2-3=-1275/1025,3-4=-9131708,4-5=-829[705,5-6=-565/E)07 ' 6-7=J565/807
7-8=-1 04/278, 8-9=-341/235
BOTCHORD 2-15=-836/1187,13-15=-34/309,11-13=-256/348,9-11=-124/304
WEBS 3-15=-425/501,5-,15=-444/66515-13=-1215/1079,6-13=-264/300,�-11=-255/396,
8-1 1=-461/521, 7-13=-8371703
Structural wood sheathing directly applied or 5-11-9 oc puffins.
Rigid ceiling dire6tly applied or 6-0-0 oc bracing.
NOTES-
1 ) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL:=4.2psf; lJCDL=3.0psf; h=14ft; B=52ft; L=3411; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-0 Exterior(2) -1-0-0 to 2-4-13, Interior(l) 2-4-13 to 5-2-5, Exterior(2) 5-2-5 to
10-0-0, Interior(l) 14-9-11 to 19-2-5, Exterlor(2) 24-0-0'to 35-0-0 zone;C-C for me�ibers and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pondIng.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent ith any other live loads.
5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of witl istanding 100 lb uplift at Joint(s) except at=lb)
2=430,9=249,13=928.
Thomas A. Albani PE No.39380
MiTek USA, Inc. I'L Cert 6634
8904 Parke East Blvd. Tampa FL 3361D
Date:
February 21,2018
WARNING - Verifydesign parameters andREAD NOTES ON THISAND INCLUDED MITEKREFER�NCE PAGE M11-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MF[ekO connectors. This design Is based only upon parameters shown,
a truss system. Before use, the building designer must verify the applicability of design param6ters
and Is for an Individual building component. not
and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord
members only. Additional temporary and permanent bracing
MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and propeN
damage. For general guidance regarding the
fabricallort storage, delivery, erection and bracing of trusses and truss systems; seeANSI/TPI I
Safety Information available from Truss Plate Institute, 218 N. Lee Street Suite 312. Alexandria,
Quality Criteria, DSB-89 and BCSI Building Component
�A 22314.
6904 Parke East Blvd.
Tampa, FIL 33610
Job '
Truss
Truss Type
city
Ply
62'Grand Cart n III with porch
T13302396
M11323
GRA
HIP
I .
1
Job Reference ( ptional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 S bep 15 2011 Mii ek industries, inc. vvea t--eD zi 14:1 v:ov zui u Page i
ID:—etClexC3ixVV?huls?ypJyuFUK-XSEZq9LDhnOwiDx?cO6cpTEfaGKGyBpOVZIMFbziuKE
8-0-0 1 1-0-0 22 0 34-0�O 5g
-4 1 il
�11-001 0-1
B-0-0 5-1
1186-001
1 3� 3-9-� 8 -0- -0-0
TOP CHORD MUST BE BRACED BY END JACKS,
Scale 1:60.6
ROOF DIAPHRAGM , OR PROPERLY CONNECTED
PURLINS AS SPECIFIED.
44
-
11 14
19
9
7 x10
17 6x10
4
4.00 F1-2
3x6 = f::;i� 19
— rTJ
3
5
13 16 5 21
2
22 C�
2 3 �2
C?
6
29 28
27
25
26 24
34 11 3x6 =
6X8 3x6 6x8 4x4
3x5 6X8
1 1- 18-6-0
26-0-0 L4-0-0
7-�-1
5 7-6-0 8_0_0
Plate Offsets (X,Y)-- 12:0-2-2, Edge], [3:0-3-8, Edge], [21:0-3-8, Edge], [24:0-3-8,0-3-01,
f2TO-3-8,0-3-01
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.91
Vert(LL) 0.20 24-35 >914 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.57
Vert(CT) -0.24 29-32 >552 240
BCLL 0.0
Rep Stress Incr NO
WB 0.98
Horz(CT) 0.02 22 rVa n1a
BCDL 10.0
Code FBC2017/-FP12014
Matrix -MS
Weight: 194 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOPCHORD Structural wood sheathing directly applied or 4-2-5 oc puffins.
BOTCHORD 2x4 SP M 30
Except:
WEBS 2x4 SP No.3
1 Row at midpt 8-21
BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
JOINTS I B race at Jt(s): 7. 8, 19, 17, 14
REACTIONS. All bearings 0-8-0.
(lb) - Max Horz 2=-1 79(LC 6)
MaxUplift All uplift 100 lb or less atjoint(s) except 2=-351(LC 8),
27=-1168(LC 8), 26=-1495(LC 8),
22=-625(LC 8)
1
MaxGrav All reactions 250 lb or less at joint(s) except 2=487(LC
7),27=2232(LC13),26=2929(LC14),
22=984(LC 14)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except wn.
TOPCHORD 2-3=-621/387, 3-5=-304/83B, 5-7=-588/1209, 7-8=-588/1209, 8-12 -588/1209,
12-13=-588/1209,13-15=-588/1209,15-16=-588/1209,16-18=-583/1209,
18-20=-2230/1280, 20-21=-2230/1280, 21-22=-2271/1263, 6-9�1 26/305, 9-1 1=-106/363,
11-14=-1 93/412,14-17=-94/271,19-21=-143/272
BOTCHORD 2-29=-247/677, 27-29=-1 89/540, 26-27=-779/446, 24-26=411/6& 1, 22-24=-1 083/2108
WEBS 3-29=-500/1176, 3-27=- 1766/911, 5-27=-748/622, 5-26=-546/351, 13-26=-946/617,
18-26=-2412/1474,18-24=-846/1780, 21-24=-35/351, 4-5=-608/514,19-20=-335/305,
14-15=-556/407,11-12=-254154 I
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2pST; �UUL=3.0psf; h=14ft; B=52ft; L=3411; eave=6ft; Cat.
11; Exp C; Encl., GCpi=O.l 8; MWFRS (directional); Lumber DOL=11.60 plate grip DOL=11.60
3) Provide adequate drainage to prevent water poncling.
4) All plates are 2x3 MT20 unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members. 1
7) Provide mechanical connection (by others) of truss to bearing plate capable ol wirl War OR ig 351 lb uplift at joint 2, 1168 lb uplift at
joint 27, 1495 lb uplift at joint 26 and 625 lb uplift at joint 22.
8) Girder carries hip end with 8-0-0 end setback.
9) Graphical puffin representation does not depict the size or the orientation of the Irlin along the top and/or bottom chord.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support c.6ncentrated load(s) 967 lb down and 461 lb up at
26-0-0, and 967 lb down and 461 lb up at B-0-0 on bottom chord. The design/s6llection of such connection device(s) is the
responsibility of others. I
11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted a.s front (F) or back (B).
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
,& WARNING- Verify cfesign parameters and RE40 MOTES ON THIS AND INCLUDED MITEK REFERAMCE PAGE M11-7473 rev. 10/012016 BEFORE USE.
Design valid for use only wIth MlTek8 connectors. This design Is based only upon paramete4 shown. and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chdrd members only, Additional temporary and permanent bracing
MOW
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication. storage. delivery, erection and bracing of trusses and truss Systems. secAN31/1PI I Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute. 218 N. Lee Street Suite 312, Alexandria, VA 22,314.
6904 Parke East Blvd.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
62'Grand Carlton III with porch
T13302396
M11323
GRA
HIP
1
1
Job Reference optional)
Chambers Truss, Inc., I-ort Fierce, t-l-
D—v� vp !uav . i. uo;—' "�. w
ID:_etClcxC3ixVV?huls?ypJyuFUK-XSEZqgLDhnOwiD)OcO6cpTEfaGKGyBpOvzlMFbziuKE
LOAD CASE(S) Standard I
1) Dead + Roof Live (balanced): Lumber Increase--'1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 21-23=-54, 29-30=-20, 24-29=-47(F=-27), 24-33=-20, 3-1 1=-126(F=-72)'
Concentrated Loads (lb)
Vert: 29=-641 (F) 24=-641 (F)
11-21=-126(1`�72)
WARNING- Verity design parameters and REW NOTES ON THIS AND INCLUDED MIrEK REFERANCE PAGE Mll-7473 rev. 1010=015 BEFORE USE.
Design valid for uso only with MITek8 connectors. This design Is based only upon paramete� shown, and Is for an IndivIduall building component. not
0 truss System. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chbrd members only. Additional temporary and permanent bracing
MOW
Is always required for stab4lity and to prevent collapse with possible personal Injury and prol)-arty damage. For general guidance regarding the
faloficatilori storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information avallable from Truss Plate Institute, 218 N. Lee Street, Suite 312., AlexandrIp. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
62' Grand Carlton III with porch
T13302397
M11323
GRB
HIP
Job Reference optional)
LonamDers i russ, inc., r-U[L nUlk;e, rL
B-0-0 13-8-C
4--_0040 8-0-0 5-8-0
5x8 MT1 8HS
4.00 F12
3
2
21 r�6 _
4x6 =
Plate
16
3x6 11
2x3 11 4x6
23 4 5 6
15 14
5x6 = 6x12
20-4-0
:yyrq04M78G4raWBLWyuFUJ-TqMKFrNTDOedyW4NkRB4uuKlw4_?Q6XhNGETJTziuKC
?0-4-0 6-00 34-0-0
L
3-4-0 5_'_� 8-0-0 1 0-0
Scale = 1:58.6
5x8 MT18HS
2X3 11
7 24 8
Y—r'r-
7
9 10 t2
13 12 11
6xl 2 = 6x6 3x6 11 46
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL.
In (loc)
I/detl
Lid
TCLL 20.0
Plate Grip DOL
1.25
TO 0.80
Vert(LL)
0.22 16-19
>999
360
TCDL 7
Lumber DOL
1.25
BC 0.68
Vert(CT)
-0= 16-19
>820
240
BOLL 0�00
Rep Stress Incr
NO
WB 0.90
Horz(CT)
0.06 9
n1a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
LUMBER -
TOP CHORD
2X4 SP M 30
BOT CHORD
2X4 SP M 30
WEBS
2x4 SP No.3 *Except*
4-14,7-13: 2x6 SP No.2
REACTIONS. (lb/size) 2=1269/0-8-0,13=4057/0-8-0,9=474/0-8-0
Max Horz 2=90(LC 7)
Max Uplift 2=-853(LO 8),13=-2590(LC 8), 9=-345(LC 8)
Max Gram 2=1 451 (LC 13), 13=4743(LC 15), 9=528(LC 14)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when �
TOP CHORD 2-3=-3625/1950, 3-4=-2080/1236, 4-6=-2080/1236, 6-7=-1296/2
8-9=-751/370
BOTCHORD 2-16=-1729/3460,14-16=-1753/3525,11-13=-262f733, 9-1 1=-2,
WEBS 3-16=-435/1209, 3-14=-1552/774, 4-14=-837/691, 7-13=-878171
8-1 1=-432/1204, 6-14=-1453/2814,6-13=-3198/1807
BRACING-
TOPCHORD
BOTCHORD
WEBS
7-8=-1296/2589,
1/668
3. 8-13=-3635/1919,
PLATES GRIP
MT20 244/190
MT18HS 244/190
Weight: 153 lb FT = 0%
Structural wood sheathing directly applied or 3-1-14 oc, purlins.
Rigid ceiling directly applied or 5-3-14 oc bracing.
I Row at midpt 3-14, 8-13,6-13
NOTES-
1 ) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.Zpsi; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water poncling.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.Opsf on the bottom chord In' all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 853 lb uplift at joint 2, 2590 lb uplift at
joint 13 and 345 lb uplift at joint 9.
8) Girder carries hip end with B-0-0 end setback. I
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at
26-0-0, and 967 lb down and 461 lb up at B-0-0 on bottom chord. The design/selection of such connection device(s) is the
responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss aie , 10wu EIS 110111 kr-I or back (B).
LOAD CASE(S) Standard Thomas A. Albani PE No.39380
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1 .25 MiTek USA, Inc. FL Cert 6634
Uniform Loads (plf])
Vert: 1-3=-54, 3-8=-131(F=-77), 8-10=-54,16-17=-20,11-16=-49(IF=-2�), 11-20=-20 8904 Parke East Blvd. Tampa Fl. 33610
1 Date:
February 21,2018
�nntiniiprl on nqnp 9
A WARNING- Verify design parameters and REW NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M117473 rev. 101012015 BEFORE USE.
Design valid foruse only with MR06 connectors. Thisclesign Is based onlyupon parameters shown, and Isforan Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design pdrameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or 6hord members only. Additional temporary and permanent bracing MOW
Is always required for stability and to prevent collapse with possible personal Injury and �roperty damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSIfTPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Tmss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 3 3610
Truss Type Qty Ply 162' Grand Carlton I I I with
T13302397
M 11323 1 GRB
Chambers Truss, Inc., Fort Pierce, F
LOAD CASE(S) Standard
Concentrated Loads (lb)
Vert: 16=-641 (F) 11 �641 (F)
HIP i Job Reference (optional)
8.130 s Sep 16 2017 MiTeK industries,
ID:SrRaEyyrqG4M78G4raWBLWyuFUJ-TqMKFrNTDOedN
Feb 21
,&WARNING -Verify destgnparamaters and READ NOTES ON THIS AND INCLUDED MrrEKREFERANCE PAGE Mit-7473 rev. 101012015 BEFORE USE.
Design valid for use only will) Mlleka connectors. This design Is based only upon parame , ters shown, and Is for an Individual building component, not
a truss system. Before use. the building designer must verify the applicability of design p6rameieis and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or �Ihorcl members only. Additional temporary and permanent bracing
MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and 0operty damage. For general guidance regarding the
fabrication, storage, delivery. erection and bracing of trusses and truss systems, se-e-ANSI/IPI I Quality Criteria, DSO-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information avollable from Truss Plate.insfiturte, 218 N. Lee Street Suite 312, Alexari,dria, VA 22,314.
Tampa, FIL 33610
Job
Truss
Truss Type
City
ply
62' Grand Carlton I I I with porch
T13302398
M11323
J2
MONO TRUSS
Job Reference (optional)
unamDers I russ, Inc., �-ort vierce, r-L
2
3x4 =
4.00FI-2
ID:xl?zSlzTbJCDIIrGPHiQukyuFUI-TqMKFrNT�Ye�;W�t,�FW�uu�Bb47'� IiWI4d�TJTziuKC
9-n-n
3
4
Scale = 1:7.8
1
1 2-0-0
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in (loc) I/defi Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL) -0.00 7 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.07
Verl(CT) -0.00 7 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00 3 n/a n1a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 8 lb FT = 0%
LUMBER- BRACING-
TOPCHORD 2x4 SP No.3 TOPCHORD Structural wood sheathing directly applied or 2-0-0 oc purlins.
BOTCHORD 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=38/Mechanical, 2=141/0-8-0, 4=22/Mechanical
Max Horz 2=67(LC 10)
Max Uplift 3=-28(LC 10), 2=-136(LC 10), 4=-3(LO 7)
Max G rav 3=39 (LC 15), 2= 141 (LC 1), 4=31 (LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C C formembers and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60 i
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections. 1
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3, 136 lb uplift at joint
2 and 3 lb uplift at joint 4. 1
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
8904 Parke East Blvd. Tampa Fl. 33810
Date:
February 21,2018
,&WARNING -Verify design parameters and READ NOTES Off THIS AND INCLUDED MITEKREFERANCE PAGE 11111-7473 rev. 1OW12015 BEFORE USE.
Design valid for use only Ain MIT" connectors. This design Is based only upon paramleters shown. and Is for an Individual building component. not
a truss system. Before use, the building designer must vertly the applicability of design �arameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/ot chord members only. Addlilonal temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury andiproperly damage. For general guidance regarding the
falodcallon. storage. delivery, erection and bracing of ttusses and truss systems. seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Paike East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Street. Suite 312, AlexcincIft VA 22-314. .
Tampa, FL 33610 -
Job
Truss
Truss Type
Q py
Ply
62'Grand Carlton III with porch
T13302399
M11323
J4
MONO TRUSS
8
Job Reference (optional)
L;namDers i russ, mc., r-on merce, r-L
2
3x4 =
6. i.30 5 OLP 1D eVi 1 IVII IV& !I IU-11—, 111- . . . . �t)
I ID:PDYLfd 5MdK4MSQTZ?ZfRxyuFUH-ylwiTBN5—imUZgfa]BfJR6s]—UP79nvqbwzoswziuKB
4-0-0
A_A_n
4.00 [1-2
3
4
Scale = 1:11.1
LOADING (pst)
SPACING- 2-0-0
CS1.
DEFL. in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Gdp DOL 1.25
TC 0.39
Vert(LL) 0.02 4-7 >999 360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.37
Vert(CT) -0.02 4-7 >999 240
EICLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00 3 n/a n/a
BCDL 10.0
Code FBC2017TrPI2014
Matrix MP
Weight: 14 lb FT = 0%
LUMBER- BRACING-
TOPCHORD 2x4 SP No.3 TOPCHORD Structural wood sheathing directly applied or 4-0-0 oc purlins.
BOTCHORD 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=90/Mechanical, 2=207/0-8-0, 4=50/Mechanical
Max Horz 2=1 04(LC -10)
Max Uplift 3=-80(LC 10), 2=-161(LC 10), 4=-7(LC 10)
Max Grav 3=90(LO 1), 2=207(LC 1), 4=69(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES- I
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterion(2) zone;0 -C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconCL rrent with any other live loads.
3) * This truss has been designed for a live load of 20.Opsf on the bottom chorc in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable )f withstanding 80 lb uplift at joint 3, 161 lb uplift at joint
2 and 7 lb uplift at joint 4.
Thomas A. Albani PE No.39380
MiTek USA, Inc. I'L Cart 6634
6904 Parke East Blvd. Tampa Fl. 33610
Date:
February 21,2018
WARNING- Verify design parameters and READ NOTES ON THISAND INCLUDED MITE� REFERANCE PAGE MIP7473 rev. 10/03)2016 BEFORE USE.
Design valid for use only wilh MITek8 connectors. This design Is based only upon parameters shown. and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of desIgA parameters and property Incorporate this design Into the overall
OF
building design. Bracing Indicated Is to prevent buckling of individual truss web anaj& chord members only. Additional temporary and permanent bracing
MiTek*
Is always required for stability and to prevent collapse with possible personal Injury a0d property damage. For general guidance regarding the
fabricartlor'L storage. delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee ';treat Suite 312, Ploxandda, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
62'Grand Carlto n III with porch
T13302400
M11323
J6
MONO TRUSS
9
1
i
Job Reference toptional)
unamuefs i ru55, inc., MIL rivnx, rL
ID:tP6jt7_�i.*�.-.-�Xi4uzgyuFUG-QDT4gXOklouLBqEmrsBYzJPUDtd4uE9zqajZOMziuKA
6-0-0
-11-00-00 6-0-0
2
3x4 =
4.00FI-2
LOADING (psf)
SPACING-
2-0-0
CS1.
I
DEFL.
. in
(loc)
I/def]
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC
0.36
Verl(LL)
0.11
4-7
>629
360
TCDL
7.0
Lumber DOL
1.25
BC
0.8�
Vert(CT)
-0.12
4-7
>617
240
BCLL
0.0
Rep Stress Incr
YES
WB
o.od
Horz(CT)
-0.00
3
n/a
n/a
BCDL
10.0
Code FBC2017/TPI2014
Matrix -MP I
LUMBER -
TOP CHORD 2X4 SP M 30
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 3=145/Mechanical, 2=279/0-8-0, 4=71/Mechanical
Max Horz 2=142(LC 10)
Max Uplift 3=-1 31 (LC 10), 2=-1 94(LC 10), 4=-8(LC 10)
Max Grav 3=145(LO 1), 2=279(LC 1), 4--102(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except
NOTES-
1) Wind: ASCE 7-10; Vult=165mpfi (3-second gust) Vasd=128mph; TCD
11; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Exterior(2)
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nor
3) * This truss has been designed for a live load of 20.0psf on the bottom
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate cal
joint 2 and 8 lb uplift at joint 4.
shown.
Scale = 1:14.6
3
4
PLATES GRIP
MT20 244/190
Weight: 20 lb FT = 0%
BRACING-
TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
for members and forces & MWFRS for reactions
rent With any other live loads.
in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
withstanding 131 lb uplift at joint 3, 194 lb uplift at
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 3361D
Date:
February 21.2018
WARNING - Verifydesign parameters and READ NOTES ON THIS AND INCLUDED Milan REFERAME PAGE Ull-7473 rev. 1010312015 BEFORE USE.
Design vaild foruse only with MITek6 connectors. This design is based only upon parameters shown. and Is for an Individual building component. not
a truss system. Before use, the building designer must verify the applicability of desIdn parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/of chord members only. Addillorwil temporary and permanent bracing
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
MiTek*
fabirtcation, storage. delivery, erection and bracing of trusses and truss systems� seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312, A16xonclda, VA 22314.
I- - - -
Tampa, FL 33610
MONO TRUSS
1 Job Re
s Sep 15 2017
with porch
mal)
.ties, Inc. Wed Feb 21
T13302401
M1 1323 1 J8
Chambers Truss, Inc., Fort
-1-0-0
1-0-0
1� 1
2
3x4 5r
8
9
4.00 F1_2
ID:tP6jt
8-0-0
8-0-0
4
0 Scale = 1: 17.4
Plate Offsets (X,Y)-- [2:0-3-14,0-1-81
1
LOADING (psf)
SPACING-
2-0-0
CSI. I
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.62
Vert(ILL) 0.26
4-7 >367 360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.36
Vert(CT) -0.30
4-7' >319 240
BCLL 0.0
Rep Stress Incr
YES
WB 0.015
Horz(CT) -0.00
3 n/a n/a.
BCDL 10.0
Code FBC2017/TP12014
Matrix-M
Weight: 26 lb FT = 0%
LUMBER-
BRACING-
TOPCHORD 2x4 SP M 30
TOPCHORD
Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOTCHORD 2x4 SP M 31
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=188/Mechanical,2=352/0-8-0,4=103/MechanicaI
Max Harz 2=1 80(LC 10)
Max Uplift 3=-1 75(LC 10), 2=-228(LC 10), 4=-1 5(LC 10)
Max Grav 3=188(LC 1), 2=352(LO 1), 4=145(LC 3)
FORCES. (11p) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=,+.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; lHxp C; Encl., GCpi=0.18; MW`FRS (directional) and C-C Exterior(2) -1-0-'0 to 2-4-13, Interior(l) 2-4-13 to 3-1-13, Exterior(2) 3-1-13
to j-1 1-8 zone;C-C for members and forces & MWFRS for reactions -shown,; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.Opsf on the bottom cho[d in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate cap of withstanding 175 lb uplift at joint 3, 228 lb upliftat
joint 2 and 15 lb uplift at joint 4. 1
Thomas A. Ahani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MIFEKREFERANCE PAGE Mll-7473 rev. 1010312015BEFOREUSE.
Design valid for use only with MITek6 connectors. This design Is based only upon Parameters shown, and Is for an Individual building component. not
a truss system. Before use, the building designer must verify the applicability of d6sign parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web q1nd/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and buss systems. seeANSI/TPI I QUGIItV CFiterI0, DSE-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from 1russ Plate Institute, 218 N. Lee Street. Suite 312.iAlexandfla, VA 22314. Tampa, FIL 33610
Job
Truss
Truss Type
Qty
Ply
62'Grand Carlton III with porch
T13302402
M11323
KJ8
MONO TRUSS
4
1
Job Reference (optional)
ChaMbers Truss, Inc., Fort Pierce, FL
8.130 s Sep i5 2Oi7 MiT ek industries, inc. Wed reu 2 1 14.20;05 40 io raqu i
ID:Lcg54J?LuEancmZr4Qb7WMyuFUF-Mcbr5CC�-Hd83Q80gzHD02kUrohRsMlVGHuCgSEziuKB
11-3-0 1
1-5-0 7-3-4
Scale = 1:20.3
3x4
3x4
7-d-4 -1
3-11-12
LOADING (pst)
SPACING- 2-0-0
CS1.
DEFL. in
(loc) I/defl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.29
Vert(LL) 0.07
7-10 >999 360
MT20 244/190
TGDL 7.0
Lumber DOL 1.25
BC 0A0
Vert(CT) -0.12
7-10 >999 240
BCLL 0.0
Rep Stress Incr NO
WB 0.46
Horz(CT) 0.02
6 n/a n/a
BCDL 10.0
Code FBC2017rrPI2014
Matrix -MS
Weight: 44 lb FT = 0%
LUMBER-
BRACING-
TOPCHORD 20 SP M 30
TOPCHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOTCHORD 2X4 SP M 30
BOTCHORD
Rigid ceiling directly applied or 8-9-6 oc bracing.
WEBS 20 SP No.3
REACTIONS. (lb/size) 4=20 1 /Mechanical, 2--466/0-11-5, 6=576/Mechanical
Max Harz 2=244(LC 8)
Max Uplift 4=-205(LC 8), 2=-305(LC 8), 6=-286(LC 8)
Max Grav 4=245(LC 13), 2=466(LC 1), 6--590(LC 13)
Jen
FORCES. Qb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except shown.
TOP CHORD 2-3=-1 151/523
BOTCHORD 2-7=-687/1126, 6-7=-687/1126
WEBS 3-7=01330, 3-6=-1236f755
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 pl
2) This truss has been designed for a 10.0 psf bottom chord live load nonc
3) * This truss has been designed for a live load of 20.Opsf on the bottom c
will fit between the bottormchord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate cap�
joint 2 and 286 lb uplift at joint 6.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are
?psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
grip DOL=1.60
urrent with any other live loads.
d in all areas where a rectangle 3-6-0 tali by 2-0-0 wide
of withstanding 205 lb uplift at joint 4, 305 lb uplift at
as front (F) or back (B).
LOAD CASE(S) Standard I
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate lncrease=1.25
Uniform Loads (pit)
Vert: 1-2=-54
Trapezoidal Loads (pit)
Vert: 2=0(F=27, B=27)-to-4=-152(F=-49, B=-49), 8=0(F=10, BJ0)-to-5=-56(F=-18, B=-18)
Thomas A. Albani PE No.39330
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa Fl. 33610
Date:
February 21,2018
WARNING -Verify design parameters and RE4D NOTES ON THIS AND INCLUDED UITEK REFERANCE PAGE M117473 rev. 10103)2015 BEFORE USE.
DesIgn valid for use only with MlTek6 connectors. IhIs design is based only uponiparameters shown, and Is for an Individual bulldlng component not
MF
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web, and/or chord members only. Additional temporary and permanent bracing
MiTek'
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regardIng the
fabricatiort storage, delivery, erection and bracing of trusses and truss systems, �eeANSIJTPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke rest Blvd.
Safety Information available from Iruss Plate Institute. 218 N. Lee Street, Suite 31?, Alexandda.VA 22314. 1
Tampa, FL 33610
Symbols
PLATE LOCATION AND ORIENTATION
Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths,
Apply plates to both sides of truss
and fully embed teeth.
--t-
For 4 x 2 orientation, locate
plates 0-1/id' from outside
edge of truss,
This symbol indicates the
required direction of slots in
connector plates.
*Plate location details available in MiTek 20/20
software or upon request.
PLATE SIZE
The first dimension is the plate
width measured perpendicular
4 x 4 to slots, Second dimension is
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing
if indicated.
BEARING
Indicates location where bearings
(supports) occur, Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
ANSI/TP11: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
Numbering System
6-4-8 dimensions, shown in ft-in-sixteenths
(Draw ngs not to scale)
2 3
TOP CHORDS
0
a:
0
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
PRODUCT CODE APPROVALS
ICC-ES Reports:
ESR- 1311, ESR- 1352, ESR 1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
0
01
0
a-
0
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
@ 2012 MiTek(5 All Rights Reserved
MITek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015
A General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal Injury
1 . Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested porhes.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane otioint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI/TPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 190/. at time of fabrication.
9. Unless expressly noted, this design Is not applicable for
use with fire retardant preservative treated, or green lumber.
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
comber for dead load deflection.
-size, -orientation-and-location dimensions
�re minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or purlins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not Shown are the responsibility of others,
16. Do not cut or after truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front back, words
and pictures) before use. Reviewing pictures alone
is not sufficient.
20. Design assumes manufacture in accordance with
ANSI/TPI I Quality Criteria.