FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation -Residential Perfbrmance Method
Prciect Name: THIEL RESIDENCE
Builder Name MtL-RY CONSTRUCTION
Street 10725 S OCEAN DRIVE
PermitOffice: STLUCIECOUNTY
City. State, zip: JENSEN BEACH. FL,
Permit Number: �
Owner.,
Jurisdieficn: ST LUCIE COUNTY
Design Location: FL. Fat Pierce
County. St: Lucie (Florida Climalo Zone 2
1 . New constructicri or e)dsbng New (Fran Plans)
9. Well Types (193 ! 8.0 scift)
Insulabcn Area
2. Single farnilyor multiple family Single-family
a. Concrete, Block - E)d Insul, E)derior
R--4.2 1320.70 ft2
b. Frame -Wood. Adjacent
R--11.0 352.00 ft2
3. Number of units. if multiple family 1
c. Frame - Wood, E)Wor
R=13.0 165.33 fL2
4. Number of Bedrocms 2
d. N/A
R= fF
5. Is this a worst case? No
10. Ceiling Types (1454.0 scift.)
lnsulaficn Area
a. Roof Deck (Unvented)
R=20.0 1454.00 iF
6. Ccridilicned locr area above grade (fr) 1454
b. N/A
R-- it2
Ccnditicned focr area below grade (fI12) 0
c. N/A
R-- IV
11. Ducts
R fL2
7. WindoNs(1185.0 scift.) Description Area
a. Sup: Atfic. Rat Atfic. AH: AHU
6 125
a. U-Factor: Dbl. U=0.31 80.00 ffl
SHGC: SHGC=0.19
b. U-Factor: Dbl, U=0.29 75.00 fJ2
12. Coding systems
kBkjlhr Efficiency
SHGC: SHGC=0.21
a.CentralUnit 1
24.0 SEER:16.00
c. U-Faclor: Dbl. U=0.29 30.00 f12
SHGC: SHGC=0.19
13. Heaffing systems
kBtuthr Efficiency
d. U-Factor: N/A ff,
a. Electric Strip Heat
17.0 COP.1.00
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHG.C: 0.198
14. Hotwatorsystems
8. FloorTypes (1454.0 sqft) Insulation Area
a. Electric Tankless
Cap: 1 gallcns
EF: 0.990
a. Raised Flocr R=30.0 537.00 ff
b. Ccriservabon features
b. Slab -On -Grade Edge Insulaticn R--O.O 512.00 t2
Ncne
c. other (see details) R-- 405.00 fL2
15. Credits
Ncne
GlasstFloor Area: 0.127 Total Proposed MocHed Loads: 51.80
DA_QS
Total Baseline Loads: 55.93 i
I hereby certify that the plans and specilications covered by
Review of the plang and
this calculation are in compliance with the Florida Energy
I
specificationsr covered by this
9� 0
Code.
calculation inclicatE� c&;pliance
with the Florida En�rgy Code.
PREPARED B
Before construction I is completed
i
. I n-14-
DATE.
this building will be!inspected for
compliance with.Se�cfion 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code..
WE
OWNERIAGENT:
BUILDING OFF161AL:
DATE:
DATE:
- Compliance requires certification by the air hanclier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report ikith envelope leakage no greater than 7.00 ACH60 tR402. &J lad" ' OPY
I F; C
F1 In IN
611912018 3.16 PM EnergyGaugedD USA Secticri R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Tide: THIEL RESIDENCE
Bedrooms: 2
Address Typer.
Street Address
Building Type: User
Condition ad Area: 1454
Lot #
Owner Namer.
Total Stories: I
BlockJSubdhvision:
# of Units: 1
Worst Case: No
PlatBock:
Builder Name: MEL-RY CONSTRUCTION Rotate Angle: 0
Street
10725 S OCEAN DRIVE
Permitoffice., ST LUCIE COUNTY
Cross Von Illation: No
County:
St Lucie
Jurisdiction: ST LUCIE COUNTY
Whcle House Fen: No
City. State. Zip:
JENSEN BEACH,
Family Type: Sin gle-family
FL,
New/E)dsting: New (From Plans)
Comment
CLIMATE
V
Design Tamp
Int Design Tamp
Heading
Design
Daily Temp
Design Location
TMY Site 97.5%
2.5%
lArinter
summer
Degree days Moisture
Range
Fl, Fort Pierce FL VERO-BFACH-IMUNI 39
so
.70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1454 11632
SPACES
Number Name
Area Volume Kitchen Occupan Is
Bedrooms
In III ID
Finished Cooled
Heated
I BEDROOM 2
258 2064 No
0
1
1
yes
Yes
Yes
2 WIC 2
30 240 No
0
1
Yes
Yes
Yes
3 BATH
50 400 No
0
1
yes
Yes
yes
4 SITTING ROOM
174 1392 No
0
1
Yes
Yes
Yes
5 MASTER BEDROO
213 1704 No
0
1
1
yes
Yes
Yes
6 M BATH
66 528 No
0
1
yes
yes
Yes
7 MWIC
34 272 No
0
1
Yes
Yes
Yes
8 KITCHEN
185 1480 yes
0
1
Yes
Yes
Yes
9 AHU
28 224 No
0
1
yes
Yes
Yes
10 LIVING
343 2744 No
0
1
yes
Yes
Yes
I I M CLST
11 88 No
0
1
Yes
yes
Yes
12 STAIRS UP
62 496 No
0
1
Yes
yes
Yes
FLOORS
v# Flocr Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
- I Slab -On -Grade Edge Insulation
BEDROOM2 16.8 ft 0
258 fF
—
1 0
0
2 Slab -On -Grade Edge Insulation
WIC 2 10.3ft 0
30 ft2
—
1 0
0
- 3 Slab -On -Grade Edge Insulation
BATH loft 0
So ft2
—
1 0
0
481ab-On-drade Edge Insulation
SITTINGROOM 26.3 ft a
174 fF
—
1 0
0
5 Raised Floor
MASTER BEDRO —
213 ff
30
1 0
0
611912018 316 PM EnergyGaugedD USA Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6 Raised Floor
M BATH —
—
66, ftZ
30
1
0
0
7 Floor over Garage
MWIC —
—
0% IL7
30
1
0
0
8 Raised Floor
KITCHEN —
—
185 fL2
30
1
0
0
9 Floor over Garage
AHLI —
—
28!ft2
30
1
0
0
1 OFIccr over Garage
LfVING —
—
34i t-
30
1
0
0
1 lRaised Floor
M CLST —
—
11 ift.
30
1
0
0
12Raised Floor
STAIRS UP —
62 ftZ
30
1
0
0
ROOF
V
Root
Gable
Root
Sclar SA
Emitt
Emitt
Dock
Pitch
# Type
Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
I Hip
Mated 1575 ft2
0 t2
Light
10.6
No 0.9
No
20
22.6
ATTIC
V
# Type
Ventilation
Vent Rato (1 in)
Are�
RBS
IRCC
I Full affic:
Unvented
a
1454 1�
N
N
CE3 LING
V # Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frar Truss Type
1 Under Aft (Linven ted)
BEDROOM 2
20
Blown
258 fE
0.1
Wood
2 Under Atfic (Unven ted)
WIC2
20
Hown
30 f12
0.1
Wood
3 Under Alto (Linven Led)
BATH
20
Blown
50 fL2
0.1
Wood
4 Under Atfic: (Unvented),
SITTING ROOM
20
Blown
1
174 f12
0.1
Wood
5 Under Atfic: (Unven tad)
MASTER BEDRO
20
Blown
213 ft'
0.1
Wood
6 Under Atfic (Unvan led)
M BATH
20
Blown
66 fL2
0.1
Wood
7 Under Adc; (Unven Led)
MWIC
20
Hawn
34 ft'
0.1
Wood
8 Under Atfic: (Unven tad)
KITCHEN
20
Blown
185 ft2
0.1
Wood
9 Under Atfic: (Unvenbed)
AHU
20
Hown
28112
0.1
Wood
10 Under Attic (Unvented)
LIVING
20
BoiAn
343 ftZ
0.1
Wood
I I Under Attic (Unvented)
M CLST
20
Hawn
11 ff
0.1
Wood
12 Under Attic (Unvented)
STAIRS UP
20
Blown
62 fF
0.1
Wood
WALLS
Adj acen t
v
Covity Width
Height
Sheathing Framing
Sclar
Below
Omf 10 !AIAII IVPQ
Space R-�Ihh
I a Ff In
Ef
In'
Area
RAM -le Emulfico
Ahqcr
r-rade%
1 SW Exterior Concrete Block - Ext InsffiEDROOM 2
42 16
9 8
0
134.0 fti
0
0
0.6
0
2 SE Exterior Concrete Block
- Ext Insul WIC2
4.2 5
0 8
O�
40.0 fI!2
0
0
0.6
0
3 SW Exterior Concrele Block - Ext Insul WIC2
4.2 5
5 8
0.
43.3 ff
0
0
0.6
0
4 SE Exterior Concrete Block
- Ext Insul BATH
4.2 10
0 8
0
80.0 f12
0
0
0.6
0
611912018 3r.16 PM EnergyGauge@ USA Section R405.4.1 Compliant Sokware Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
ya
Adjacent
Cavity Width
Height
Sheathing Framing
Soler
Below
()Mt
10
WAII T4PG Space
R--3h'l f a Et In
Et In
AUM
R.3M,le
Fraction
Ahq-
rrade:0A
5
NE
Exterior
Concrete, Block - Ext InsuSITTING RO
4.2 Is
5
8 0
123.3ft'
a
a
0.6
0
6
SE
Exterior
Concrete Block - Ext InsuSITTING RO
4.2 11
0
8 0
88.0 ft2
0
0
0.6
0
7
NE
Exterior
Concrete, Block - Ext InsLMASTER BE
4.2 14
2
8 0
113.3 ft2
0
0
0.6
0
8
S E
Exterior
Concrete Blork - Ext InsLMASTER BE
42 18
0
8 0
144.0 ft'
0
0
0.6
0
9
SE
Exterior
Concrete Blork - Ext Insul M BATH
42 4
0
8 0
32.0 f12
0
0
0.6
0
10
S;
Exterior
Concrete Block - Ext Insul M BATH
4.2 9
0
a 0
72.0 f12
0
0
0.6
0
11
SW
Exterior
Concrete Block - Ext Insul KITCHEN
42 11
8
8 0
93.3 ffl
0
0
0.6
a
12
NE
Exterior
Concrete Block - Ext Insul LIVING
4.2 16
2
8 0
129.3 ft2
0
0
0.6
0
13
SW
Exterior
Con crate Block - Ext Insul LIVING
4.2 13
7
8 a
108.7 ft'
0
0
0.6
0
14
W
Exterior
Frame - Wood LIVING
13 20
8
8 0
165.3 ft2
0
025
0.6
0
15
N
Exterior
Concrete Block - Ext Insul M CLST
42 2
3
8 0
18.0 fL2
0
0
0.6
0
16
NE
Exterior
Concrele Block - Ext InsuISTAIRS; UP
4.2 12
8
8 0
101.3 ft'
0
0
0.6
0
17
N
Garage
Frame - Wood BEDROOM 2
11 6
8
48.0 ft2
0
0-25 0.600000 0
18
S
Garage
Frame - Wood STAIRS UP
11 13
8
104.0 ft2
0
025 0.600000 0
19
W
Garage
Frame - Wood BEDROOM 2
11 25
8
200.0 ftZ
0
025 0.600000 0
DOORS
V
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
i
Ft
In
Ft In
I
NE
InsulaL-d SITTING RO
None
�39
3
6 8
20 ft'
WINDOWS
Orientalion shown is the entered. Proposed
orientation.
wall
Overhang
#
Omt ID
Frame Panes NFRC U-Factcr
SHGC
Imp
Araa
Depth
Separation
Int Shade
Screening
1
SW I
Vin yl Low-E Double Yes
029 0.19
Y
15.0 ft'
1 ft0in
A ft4in
None
None
2
NE 5
Vinyl Low-E Double Yes
0.29 0.21
Y
15.0 ff
1 ft0in
I ft4in
None
None
3
NE 7
Vinyl Low-E Double yes
0.29 021
Y
15.0 ff
1 ft0in
I ft4in
None
None
4
SE 8
Vin y! Low-E Double Yes
029 0.19
Y
15.0 ft'
1 ft0in
I ft4in
None
None
5
S 10
Vin yl Low-E Double Yes
0.29 021
Y
6.0 ft2
I ft0in
I ft4in
None
None
6
SW 11
Vin)A Low-E Double Yes
0.29 0.21
y
9.0 ft2
I ft 0 in
I ft4in
None
None
7
NE 12
Vin yl Low-E Double Yes
0.29 0.21
Y
15.0 R2
1 ft0in
I ft4in
None
None
8
SW 13
Viin)A Low-E Double yes
029 021
Y
15.0 ft2
1 ft0in
I ft4in
None
None
9
W 14
Viiny Low-E Double yes
0.31 0.19
Y
80.0�fr
I ft 0 in
I ft4in
None
None
GARAGE
#
FloorArea Ceiling Area Exposed Wall Perimeter
Avg!. Wall Height
Exposed Wall Insulation
1
550 ftZ 550 22
44ft
8 ft
I I
6119/2018 316 PM EnergyGaugee USA Section R405.4.11 Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Sccpe Method
SLA
CFM 50 ELA EqLA ACH ACH 50
I Whclehouse, Proposed ACH(50)
.000356
1357.1 74.5 140.11 .2578 7
HEATING SYSTEM
V # System Type
Subtype
Efficiency Capacity Block
Ducts
I Bectric Strip Heatf
None
COPA 17kBtu)hr 1
sys#Ml
COOLING SYSTEM
V # System Type
Subtype
Efficiency CEi0acity Air Flow SHR Block
Ducts
1 Central Unitf
Split
SEER: 16 24 kBtu/hr 720 c1rn 0.8 1
sys#1
HOT WATER SYSTEM
V# System Type SubType
Loration
EF Cap Use SetPnt Conservation
I Electric Tankless
Garage
0.99 1 gal 55.1 gal 120 deg None
SOLAR HOT WATER SYSTEM
v FSEC
Cert # Company Name
Collector Storage
System Model # Collector Modd # Area Vdume
FEF
None None
t2
DUCTS
-- Supply
V # Location R-Value Area
Return Air CFM25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
WAC #
Heat Cool
I Adc 6 125 R2
Attic
13 ft2 Default Leakage AH,U (Default) c(Default) c
1 1
TEMPERATURES
Progremable Thermostat: N
J Feb Mar
Codin Ian
g
Heating an Feb Mar
Venfing Jan Feb Mar
Apr
Apr
p
Apr
Ceiling Fans:
Ila Jun Jul Au Sap Oct N Nov
y 9
un Au S Oct Nov
i Jul 9 ep
Jun Jul Aug Sep Oct Nov
HD c
Do
ac
Der
6/`19/2018 a.16 PM EnergyGauge@ USA Section R405.4.1 Compliant So.thwe Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule. HERS 2006 Reference
Hours
chedule Type
rT
1
2
3
4
5
6
7
a
9
10
11
12
cs,cc
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
so
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Healing (W D)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Healing (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
FurniturdFrarlion
Space
Default(8 lbs/sq.ft
0 ft2
0 ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft
ff,
ft
0.3
WIC 2
DefauI48 lbs/sq.ft.
ff,
ft
0.3
BATH
Default(B lbs/sq.ft.
ff,
ft
0.3
SITTING ROOM
Defauft(8 lbs/sq.ft
f12
ft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft
fF
ft
0.3
M BATH
DefauIX8 lbs/sq.ft
ff
ft
6.3
MWIC
Defauft(8 lbs/sq.ft
fe
ft
6.3
KITCHEN
DefauIX8 lbs/sq.ft
ft2
ft
6.3
AHU
Default(8 lbs/sq.ft
ft2
ft
0.3
LIVING
Defauft(B lbs/sq.ft
fL2
ft
0.3
M CLST
Default(8 lbstsq.ft
f12
ft
b.3
STAIRS UP
Name:
Rating Compant:
Date:
11 "PisMisa. i'lMatui
6119/2018 316 PM EnergyGaugef) USA Section R405.4.1 Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4,1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: THIELRESIDENCE BuilderName: MEL-RY CONSTRUCTION
Street 10725 S OCEAN DRIVE PermitOffice: STLUCIECOUNTY
City. State, Zip: JENSEN BEACH, FL, Permit Number:
Owner: Jurisdiction: ST LUCIE COUNTY
Design Location: FL. Fort Pierce
COMPONENT
A] R BARRIER CRITERIA
INSULATION INSTALLATION CRITEMA
General
A continuous air barrier shell be installed in the building envelope.
Air -permeable insulation shall
requirements
The extarior thermal envelcpe con tains a continuous air barrier.
not be Used as a sealing matedal.
Breaks orjoints in the air barrier shall be sealed.
Ceifingfattic
The air barrier in any dropped ceilin g1soffit shall be aligned with the
The insulation in any dropped ceiling/soflit
insulation and any gap in the air barrier shell be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or kneewall docirs to
unconditian ad atfic spaces shall be sealed.
Walls
Thejun ction of the foundation and sill plate shell be sealed.
Cavities within corners and headers of frame walls
Thejun ction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial con tactand confin uous
alignmen twith the air beirrier.
Windows.sWights;
The space betwom win daw/door jembs and framing. and
End docirs
skylights and framing shall be sealed.
Rimicists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Roors
The air barrier shall be installed atany exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain perman ant contact with the underside of
above -garage
su6locr docking, or loor framing cavity insulation shall
and cantilevered fiocrs)
be permitted to bein contactwith the top side of
Sheathing. or continuous insulation installed on the
Merside of floor ireming and extends from the bottorn
to the top of all perimeter floor framing members.
CrwM space walls
Exposed ear th in unvented oraW spaces shall be covered with a
Where provided instead of floor insulation. Insulation
Class I vapor retarder with overlapping joints taped.
shiiifi bepermenently attached to the craWspace walls.
Shafts. penetrations
Duct shafts. utilitypenetrations. and flue shafts opening toexterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut b It or narrow
Narrowcavities
cavities shall be filled by insulation thaton installation
reidily conforms to the availablecavity spaces.
Garagesaparabon
Air sealing shall be provided bebmeen the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed fight fixtures installed in the building
be sealed to thedrywall.
th4mal envdcpe shall be air fight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neally to It around wiring an
I
plumbing in exterior walls. or insulation thaton
installation readilyccnfcrms to available spare shall
extend behind Pinina and wirin a.
Shower/tub
The air barrier installed atexteriorwalli adjacent to showers and
Exterior wells aclacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the shawers and tubs.
I
insulated.
Electricallphoneboxon
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
WAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-loor or drywall.
Concealed
When required to be sealed. canceaded Iresprinklers; shall only be sealed
sprinklers
in a manner that is recommended by the man ufaicturer. Caulking or other
adhesive sealants shall not be used to fill voids between ire sprinkler
cover Diates and wells or ceilings.
a. in addition. inspecdon oi log wails shell be in accordance with the provisions of IGG-400. 1
6/19f2018 a17 PM EnergyGauge@ USA FBC 6th Edition (2017) Cornpliarit Sofhvare Page I of I
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 93
The lower the Energy Perlbrmance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R-
6.0
2. Single-family or multiple -family
2. Sin-gle-fami y
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Coolingjsystem: Capacity
4.0
a) Split s tem SEER
ys
16.0
5. Is this a worst case? (yes/no)
5.
No
1
b) Single package SEER
c) Grouhd/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1464
d� Room uniVPTAC EER
a) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.299
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.198
14. Heating system: Capacity__.L7.0
c) Area
7c.
185.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
a) Gas furnace, LPG AFUE
Other,
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
30.0
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.99
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank, EF
1. Wood frame (Insulation R-value)
10A1.
13.0
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
1OA2.
4.2
Q HeatIrecovery unit HeatRec%
B. Ac§acent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. WAG credits claimed (Perfbrmance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
20.0
b) Gross ventilation
No
b) Singie assembly
11b.
c) Whdle house fan
No
c) Knee wall s/skyl ight wal Is
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
a) Multizone heating credit
Q Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: 10725 S OCEAN DRIVE City/Fl- Zip: JENSEN BEACH, FL
6/19/2018 a172B PM EnergyGauge@ USA 6.0.02 - RaRes2017 FBC 6th Edition (2017) Canpliant Soft6vere Page 1 of I
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: THIEL RESIDENCE
Builder Name: MEL-RY CONSTRUCTION
Street: 10725 S OCEAN DRIVE
Permit Office: ST LUCIE COUNTY
City, State, Zip: JENSEN BEACH, FL,
Permit Number:
Owner.
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County:: St. Lucia (Florida Climate Zone 2
1. New construction or existing
New (From Plans)
9. Wall Types (11862.0, sqft.)
Insulation Area
2. Single family or multiple family
*S11 gle-family
g',,a,,,y
a. Concrete Block -Ext Insul, Exterior
R=4.1 1510.00 ft2
b. Frame - Wood, Adjacent
R=11.0 352.00 fl:2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
2
d. N/A
R= ft,
5. Is this a worst case?
No
4.OZ10. Ceiling Types (14 ft.)
Insulation Area
a. Roof Deck Unve t6d
R=20.0 1454.00 ft2
6. Conditioned floor area above grade (W)
14\541
b. N/A
71
R= ft2
Conditioned floor area below grade (fl:2)
0
c. N/A
R= ft2
'e'a
11. Ducts
'Ret:
R ft2
7. Windows(185.0 sqft.) Description
Ar
a. Sup: Att Attic, AH: AHU
6 125
a. U-Factor: Dbl, U=0.31
80.00 fl:2
SHGC: SHGC=0.19
V11
b. U-Factor: Dbl, U=0.29
75 - 00 ft L 2
12. C661ing systems
""'Central Unit
kBtu/hr Efficiency
SHGC: SHGC=0.21
a.
24.0 SEER:16.00
c. U-Factor: Dbl, U=0.29
30.00 ft2 1
SHGC: SHGC=0.19
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft2
a. Electric Strip Heat
17.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
1.000 ft.
Area Weighted Average SHGC:
0.198
14. Hot water systems
Electric Tankless
Cap: I
8. Floor Types (1454.0 scift.)
Insulation Area
a.
gallons
a. Slab -On -Grade Edge Insulation
R=0.0 1454 "i2
.00;f
b. Conservation f�atures
EF: 0.990
b. N/A
R= ft2
1 , I
N. None
c. N/A
R= ft-
?\
15. q., its
" r
None
WIN
Glass/Floor Area: 0.127
Total.Proposed Modified Loads: 4Z 17
PASS
Total Baseline
Loads: 51'1� 81
I hereby certify that the plans and specifications
covered by
Review of the plA'srand
this calculation are' in compliance with tl?e
Florida Energy
V.,'N
specifications coverech by tnis
I -
Code
calculation indicatesco"mpliance
Is f 0-
with the Florida EnergyNCode.
PREPAREDIf-
DATE:
MMIZ
Before construction is conjoleted
this building will be in, specQjor
compliance with Section 553`908
.0
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT-
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R462.4.1.2).
517/2018 2:33 PM EnergyGauge@) USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017
PROJECT
Title: THIEL RESIDENCE
Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1454
Lot #
Owner Name:
Total Stories: I
Block/Subdi%Asion:
# of Units: I
Worst Case: No
PlatBook:
Builder Name: MEL-RY CONSTRUCTION
Rotate Angle: 0
Street:
10725 S OCEAN DRIV
Permit Office: ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST LUCIE COUNTY
Whole House Fan: No
City, State,
Zip:
JENSEN BEACH,
Family Type: Single-family
FL,
New/E)dsting: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Tbmp
Heating
Design Daily Temp
Design Location TMY Site 97.5% 2.5%
Winter
S'�' mmer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEAC�I�MUNI 39 90
70,4OX,
75
299
62
Low
Will
BLOCKS
Number Name Area
�'Vqlume
I Entire House 1454 1632
SPACES
Number Name Area
Volume 11�Kjtchen qqpupants
Bedro8ms
Infil ID
Finished Cooled
Heated
I BEDROOM 2 256
2048 vo o
1
1
Yes
Yes
Yes
2 WIC 2 30
240 N,O'� 0
1
Yes
Yes
Yes
3 BATH 50
400 N4, 0
1
Yes
Yes
Yes
4 SITTING ROOM 174
1392 A6 0
X
1
Yes
Yes
Yes
5 MASTER BEDROO 213
1704 4?it"No 0
1
1
Yes
Yes
Yes
4t,;
6 M BATH 66
528 No 0
1
Yes
Yes
Yes
�ij
7 M WIC 34
272 No 0
1
Yes
Yes
Yes
8 KITCHEN 185
'0 0
14130:" Yes
I
Yes
Yes
Yes
9 AHU 28
224' No
1
Yes
Yes
Yes
10 LIVING 345
2760 No
A4, 0�1 L
1
Yes
Yes
Yes
11 M CLST 11
88 0
No
1
Yes
Yes
Yes
12 STAIRS UP 62
496 No 0
1
Yes
Yes
Yes
FLOORS
# Floor Type /1" Space Perimeter Perimeter R-Value
Aea
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insuldti, 13EDROOM 2 16.8 ft 0
'k "
256 ft?,' ,
—
1 0
0
2 Slab -On -Grade Edge Insulatio
WIC 2 10.3 ft 0
30 ft2
-
1 0
0
3 Slab -On -Grade Edge Insulatio
BATH loft 0
50 ft?
—
1 0
0
4 Slab -On -Grade Edge Insulatio SITTING ROOM 26.3 ft 0
174 A-
—
1 0
0
5 Slab -On -Grade Edge Insulatio MASTER BEDRO 32.2 ft 0
213 ft2
—
1 0
0
I
5f7/2018 2:33 PM EnergyGauge@) USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017
FLOORS
y#
Floor Type
Space Perimeter Perimeter R-Value Area
Joist R-Value
Tile
Wood. Carpet
6 Slab -On -Grade Edge Insulatio
M BATH 13 ft 0 66 ft2
-
1
0
0
7 Slab -On -Grade Edge Insulatio
M WIC 1 ft 0 34 ft2
-
1
0
0
8SIab-On-Grade Edge Insulatio
KITCHEN 11.7 ft 0 185 ft2
-
1
0
0
9 Slab -On -Grade Edge Insulatio
AHU 1 ft 0 28 ft2
-
1
0
0
10SIab-On-Grade Edge Insulatior
LIVING 53.4 ft 0 ft2
1
0
0
1(3,45
1 ISlab-On-Grade Edge Insulatio
M CLST 2.2 ft 0 11 ft2
1
0
0
U
12SIab-On-Grade Edge Insulatio
STAIRS UP 12.6 ft 0 62 ft2
1
0
0
ROOF
Roof Gable 4-T,"'Roof Solar SA Emitt
Emitt
Deck
Pitch
# Type Material's
Area Area Color Absor.
Tested
Tested
Insul.
(deg)
1 Hip Metal 1575 ft2 0 ft2o, Light 0.6'
No
0.9
No
20
22.6
ATTIC
# Type
Ventilation 6nt Ratio (1 in) Area
RBS
IRCC
1 Full attic
Unvented 0 1454 ft2
N
N
FEILING
# Ceiling Type
Space �,-,,'k-Value Ins Type Area
Framing Frac Truss Type
1 Under Attic (Unvented)
BEDROOM 2 1�20 Blown
256 ft2
0.1
Wood
2 Under Attic (Unvented)
J!,WIC 2 Blown
30 ft2
0.1
Wood
3 Under Attic (Unvented)
BATH 20 Blown
50 ft2
0.1
Wood
4 Under Attic (Unvented)
SITTING ROOM 20 W',� Blown
174 ft2
0.1
Wood
5 Under Attic (Unvented)
41"ASTER BEDRO 20 Blown
213 ft2
0.1
Wood
6 Under Attic (Unvented)
M BATH 20 Blown
66 ft2
0.1
Wood
7 Under Attic
M WIC 20 ��,,.Blown
34 ft2
0.1
Wood
(Unvented)
8 Under Attic (Unvented) KITCHEN 20 Blown
186 ft2
0.1
Wood
9 Under Attic (Unvented),
AHU 20 Blo",
28 ft2
0.1
Wood
10 Under Attic (Unvented),
LIVING 20 131=6��,
345 ft2
0.1
Wood
h�.,
11 Under Attic (Unvented)
M CLST 20 Blown 4A,,
`q"��.,:,
11 ft2
0.1
Wood
.
p
12 Under Attic (Unvente d)
STAIRS UP 20 Blown
62 ft2
0.1
Wood
WALLS
Adjacent 6,
Cavity Width Height
Sheathing Framing
Solar
Below
#
Ornt In %Afall�T'�vnp
Space R-11alue Ft In Ft In
Area
R-Nhafile Frnrtinn
Ahqor
rrqfie%-
1
SW Exterior Con;prete Block -
Et ImMDROOM 2 4.1 16 9 8 0
134.0 W
0
0
0.6
0
R
2
SE Exterior Conqrete Block -
Ext Insul WIC 2 4.1 5 0 8 0
40.0 ft-
0
0
0.6
0
3
SW Exterior Concrete Block -
Ext Insul WIC 2 4.1 5 5 8 0
43.3 f?
0
0
0.6
0
4
SE Exterior Concrete Block -
Ext Insul BATH 4.1 10 0 8 0
80.0 ft2
0
0
0.6
0
5/712018 2:33 PM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2017
WALLS
y it
nrnt
Adjacent
In Wall 1pe Space
Cavity Width Height
RAW, a Et In Et in
Area
Sheathing Framing
R-1/ahle Eranfonn
Solar
AhSor
Below
GWfJe%
5
NE
Exterior
Concrete Block - Ext InsWTING RO
4.1 15 5 8
0
123.3 ft2
0
0
0.6
0
6
SE
Exterior
Concrete Block - Ext InsSITTING RO
4.1 11 0 8
0
88.0 fl:2
0
0
0.6
0
7
NE
Exterior
Concrete Block - Ext InsMASTER BE
4.1 14 2 8
0
113.3 ft2
0
0
0.6
0
8
SE
Exterior
Concrete Block - Ext IndMASTER BE
4.1 18 0 8
0
144.0 ft2
0
0
0.6
0
9
SE
Exterior
Concrete Block - Ext InsuIM BATH
4.1 4 0 8
0
32.0 ft2
0
0
0.6
0
10
S
Exterior
Concrete Block - Ext InsulM BATH
4.1 9 0 8
0
72.0 ft2
0
0
0.6
0
11
SW
Exterior
Concrete Bloc k - Ext InsuKITCHEN
4.1 11 8 8
OY,
93.3 ft2
0
0
0.6
0
12
NE
Exterior
Concrete Block - Ext.rpn�sul LIVING
4.1 16 2 8
-129.3 f1:2
0
0
0.6
0
13
SW
Exterior
Concrete Block - Ex�t�lnsul LIVING
.!0
.4.1 13 7 8 '1" 0
108.7 fl:2
0
0
0.6
0
14
W
Exterior
Concrete Block - E� Insul LIVING
4.1 23 8 1 8
0
189.3 ft2
0
0
0.6
0
15
N
Exterior
Concrete Block - ExNLUIM CLST
4. 1 2 3 8
0
18.0 ft2
0
0
0.6
0
16
NE
Exterior
Concrete t3lOCK - Ext Insffl-AIRS UP
4.1 12 8
0
101.3 fl:2
0
0
0.6
0
17
N
Garage
Frame
- Wood BEDROOM 2
11 6 8
48.0 ft2
0
0 0.600000
0
18
S
Garage
Frame - Wood STAIRS UP
11 1 8
104.0 fl:2
0
0 0.600000 0
40-
I'll
19
W
Garage
Frame - Wood BEDROOM 2
11 ,4��5 8
200.0 ft2
0
0 0.600000 0
DdO'RS
#
Ornt
Door Type Space
A
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
I
NE
Insulated SITTING RO\,,, None
.39'
3
6 8
20 ft2
WINDOWS
Orientation shown is the�,entered, Proposed UINNIECIE1011.
Wall
Overhang
#
Ornt ID
Frame Panes NFRC U-Fact\orSUGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
SW 1
F'?
Vinyl Low-E Double fiYes
V, IN
0.29 0:119 Y
15.0 ft'i
1 ft 0 in
I ft4in
None
None
2
NE 5
Vinyl Low-E Double Yes
0.29 0.2 N, Y
1 5.0 ft2'
1 ft 0 in
I ft 4 in
None
None
3
NE 7
Vinyl Low-E Double 4V' Yes
0.29 021 Y
Xf".XY
15.0 ft-
1 ft 0 in
1 ft 4 in
None
None
4
SE 8
Vinyl Low-E Double Yes
0.29 019
15.0 ft2'
1 ft 0 in
1 ft 4 in
None
None
5
S 10
Vinyl Low-E Doubley Yes
0.29 0 21
6.0 ft-
1 ft 0 in
1 ft 4 in
None
None
6
SW 11
Vinyl Low-E Double Yes
'y 9 0 ft2.
0.29 0 21
1 ftO in
1 ft4 in
None
None
7
NE 12
Vinyl Low-E Dobible Yes
0.29 0.21 Y '%15.0
ft2,
1 ft 0 in
1 fl:4 in
None
None
8
SW 13
Vinyl Low-E D,6uble Yes
0.29 0.21 Y
1510 ft2
1 ft 0 in
1 ft4 in
None
None
9
W 14
Vinyl Low-E.,Double Yes
0.31 0.19 Y
80.'0,- -ft2
1 ft 0 in
1 ft4 in
None
None
;Q
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall\4qight
Exposed Wall Insulation
1
550 f1:2 650 ft2
44 ft
8 ft
I I
5/7/2018 2:33 PM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compiiant Software Page 4 of 6
FORM R405-2017
INFILTRATION
# Scope Method
SLA CFM 50 ELA EqLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000366 1357.1 74.5 140.11 .2598
7
HEATING SYSTEM
V # System Type
Subtype Efficiency Capacity
Block
Ducts
1 Electric Strip Heatt
None COPA 17 kBtu/hr
I
sys#1
7,
COOLING SYSTEM
# System Type
Subtype Efficie Capacity Air Flow
SHR Block
Ducts
I Central Unit/
split SEER":.F'1"6 24 kBt,/hr 720 cfm
0.8 1
sys#1
HOT WATER SYS EM
# System Type SubType
Location", EF Use SetPnt
Conservation
1 Electric Tankless
W
Garage 0.99 11 gal 55.1 gal 120 deg
None
SOL'ARHOTW ERSYSTEM
VFSEC
Collector
Storage
Cert # Company Name
ysteni:,Model # Collector Model # Area
Volume
FEF
None None
ft2
DUCTS
-- Supply
ev
Rdlufn Air CFM 25 CFM26
HVAC #
# Location R-Value Area
LocatioR,,�f Area Leakage Type Handler TOT OUT
QN RLF
Heat Cool
I Attic 6 125 ft2
Attipl, 13 ft2 Default Leakage AHU, (Default) (Default)
1 1
TEMP'E"RATURES
Prograrnable Thermostat: N
Ceiling Fans: V�!,
Cooling Jan Feb Mar
Heat Jan Feb Mar
p 9
�j% ay JuQ. Jul Au Sep
�Aprr May Jun,�, Jul Aug Sep
Oct Nov
Oct Nov
Dec
Dec
Vent Jan Feb Mar
;Apr May Jun Jul Au Sep
9
Oct Nov
Dec
5[7/2018 2:33 PM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2017
Thermostat Schedule:.
Schedule Type
HERS 2006 Reference
1
2
3
4
5
6
Hours
7
8
9
10
11 12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80 80
PM
80
80
80
80
78
78
78
78
78
78
78 78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80 80
PM
80
80
80
80
78
78
78
78
78
78
78 78
Heating (WD)
AM
65
65
65
65
65
65
65
-68
68
68
68 68
PM
68
68
68
68
68
68
6,?
68
68
68
68 68
Heating (WEH)
AM
65
65
65
65
65
65
,Av
.,-,65
68
68
68
68 68
PM
68
68
68
68
68
68
'1�,0'68
68
68
68
68 68
517/2018 2:33 PM EnergyGauge@) USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: THIEL RESIDENCE Builder Name: MEL-RY CONSTRUCTION
Street: 10725 S OCEAN DRIVE PermitOffice: STLUCIECOUNTY
City, State, Zip: JENSEN BEACH, FL, Permit Number:
Owner: Jurisdiction: ST LUCIE�' OUNTY
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
.6'
Air -permeable insulation shall
The exteriorthermal envelope contains a continuous air barrier.
'A6 be used as a sealing material.
requirements
Breaks d" joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation
The insulation in any dropped ceiling/soff it
a�6d any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openihgs, drop down stairs or knee wall doors to
unconditioned �ftic spaces shall be sealed.
Walls
The junction of tl�6,foundation and sill plate shall be sealed.,,,Y
I
Cavities within corners and headers of frame walls shall
The junction of the top plate and the top of exterior walls shbll be sealed.
be insulated by completely filling the cavity with a
Knee walls shall be s'ealed.
material having a thermal resistance of R-3 per inch
Al
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door",jarritis andframing, and
and doors
skylights and framing shall be sealed.
v
Rim joists
Rim joists shall include the air b arrier \
Rim joists shall be insulated.
Floors
"R
The air barrier shall be installed at any- exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
ill
;jY
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
A�p
be pem'litted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to thetop of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvei4ied crawl spaces shall be cover4with a
Where provided instead of floor insulation, insulation
Class I vapor retarde �i
, �/with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utilityllple'rietrations, and flue shafts opening to exte��,'
or uncondition 'S�bace shall be sealed.
I d"'.'
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
Ix
AV,
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Reces'sed light fixtures installed in the building thermal envelope shall
Recess d light fixtures installed in the building
a '
N
be�sealed to the drywall.
thermal ope shall be air tight and IC rated.
Plumbing and wiring
Battinsulatio �hall be cut neatly to fit around wiring and
plu�nbing in exted ails, or insulation that on
�Jo r w
,.
installation readily conforms to available space shall
extend behind oioi4and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent 16-s howers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. in aaaition, inspection ot log walls snail I)e in accorclance witri the provisions ot IGG-400.
51712018 2:34 PM EnergyGaugeO USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
.DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 91
The lower the EnergyPerformance Index, the more efficient the home.
1 . New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows- Description
a. U-Factor: Dbl, U=0.31
SHGC: SHGC=0.19
b. U-Factor: Dbl, U=0.29
SHGC: SHGC=0.21
c. U-Factor: Dbl, U=0.29
SHGC: SHGC=0.19
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
10725 S OCEAN DRIVE, JENSEN BEACH, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1510.00 ft2
b. Frame - Wood, Adjacent
R=1 1.0
352.00 fl:2
1
c. N/A
R=
ft2
2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
No
a. Roof Deck (Unvented)
R=20.0
1454.00 ft2
1454
b. N/A
R=
ft2
Area
c. N/A
R=
ft2
80.00 fl:2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: AHU
6 125
75.00 f?
12. Cooling systems
kBtu/hr
Efficiency
30.00 ft7
a. Central Unit
24.0 -
SEER:16.00
f?
1.000 ft.
0.198
8. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1454.00 ft2
b. N/A R= ft2
c. N/A R= ft2
13. Heating systems
a. Electric Strip Heat
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied With the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: -;?P� Date:
Address of New Home:
City/FL Zip:
kBtu/hr Efficiency
17.0 COP:1.00
Cap: I gallons
EF: 0.99
None
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/7/2018 2:34 PM EnergyGauge@) USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of I
Project Summary Job:
wrightsof-Ir Date: May07,2018
Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM
I Project Information
For: THIEL RESIDENCE, MEL-RY CONSTRUCTION
10725 S OCEAN DRIVE, JENSEN BEACH, FL
Notes:
Design Information
Weather: Fort Pierce, FL, US
Winter Design Conditions
Outside db
42
OF
Inside db
70
OF
Design TD
28
OF
Heating Summary
Structure
14247
Btuh
Ducts
3246
Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0
Btuh
PIpI9g
0
Btuh
Equipment load
17493
Btuh
Infiltration
Method
Construction quality
Fireplaces
Simplified
Average
0
Hea�tgi
Cool*"
Area (ft2)
1461
Volume (ft')
12242
12242
Air changesthour
0.45
0.23
Equiv. AVF (cfm)
. 92
47
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
5.1 kW
17493 Btuh
20 OF
800 cfm
0.046 cfm/Btuh
1.00 in H20
Summer Design Conditions
Outside db
90
OF
Inside db
75
OF
D n TD
esig
15
OF
D ally range
M
Relative umidity
50
%
Moisture difference:
61
gr/lb
Sensible Coolling Equipment Load Sizing
Structure
13263
Btuh
Ducts
4685
Btuh
Central vent (0 cfm)
0
Btuh
Blower
0
Btuh
Use manufacturerg data
Rate/swing multiplier
n
0.95
Equipment sensible load
17051
Btuh
Latent Cooling Equipment
Load Sizing
Structure
2960
Btuh
Ducts
1233
Btuh
Central vent (0 cfm)
0
Btuh
Equipment latent load
4194
Btuh
Equipment total load
21245
Btuh
Req. total capacity at 0.70 SHR
2.0
ton
Cooling Equipment Summary
Make Rheem
Trade RHEEM
Cond RA1'624AJlNA
Coll RH1T2417STANJA
AHRI ref 7940891
Efficiency 13.0 EER,
16 SEER
Sensible cooling:
16800
Btuh
Latent cooling
7200
Btuh
Total cooling
24000
Btuh
Actual air flow
800
cfm
Air flow factor
0.045
cfm/Btuh
Static pressure
1.00
in H20
Load sensible heat ratio
0.81
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
* wrightsoft, Right-SuiteG Universal 2017 17.0.08 RSU08101 2018-May-07 14:44:39
14C4;k EADocumnetslWrightsoft HVAC%THIEL RESIDENCE.rup Cale = MJ8 Front Door faces: N Page 1
wrightsoft Right-J@ Worksheet Job:
Entire House Date: May 07, 2018
QUICK CALCS, INC. By:
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
Entire House
BEDROOM 2
2
Eq)osed wall
188.4 ft
16.8 ft
3
Room height
8.4 ft
8.0 ft heat/cool
4
Room dimensions
1.0 x 258.0 ft
5
Room area
1453.7 ft2
258.0 ft2
TY
Construction
U-value
Or
HTM
Area (f?)
Load
Area (ft-)
Load
number
(Btuh/ft12F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
NIP/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
13A-4ocs
2 glazing, cIr low-e
143
0.143
0.290
ne
ne
4.00
8.12
2.19
18.74
594
15
A8
528
0
__72
2116
122
1156
281
0
0
__0
0
0
0
0
0.
0
0
1�
2 glazing, clr low-e
11D0
0.290
0.390
ne
ne
8.12
10.92
18.74
10.34
31
20
0
260
578
202
0
0
0
0
0
0
0
0
T-__G
13A-4ocs
2 gIazing,_cIrjovc-e,
13A-4ocs
_
_6.1�f3
0.290
0.143
_s6
--se
s
4.00
--,-.,-8.12
4.00
2.19
_17.69
2.19
384
__15
72
-2.0
369
66
- ____213
1477
_.,___.j22
266
co�
______265
145
_____0_
_0
0
0__
0
.----.0
6
0
T=G�
2_qlazinq, clr loviL-e-
�0.290.
s
8.12
8.75
6
6
47
50
0
0
0
0
13A-4ocs
0.143
-
sw
4.bo
_
2.19
860
�41
i �-M
A5
im
'f10
__2F76
_____260
2 glazing, cIr low-e
0.290
sw
8.12
16.89
9
2
73
152
0
0
0
0
h.2.gIazing,_cIr_Iow-e__
2 glazing, cIr low-e
0.290
sw
8.12
17.69
15
2
118
258
0
0
0
0
0.290
-sW-
.8.12
----17.69
15
2
__j25
273
___15
2
125
273
T-0
13A4ocs
gl�ging, cIr low-e
0.143
0.290
w
w
4.00
8.12
2.19
24.53
190
80
109
0
437
653
239
1972
0
0
0
0
6
0
0
0
_?
____0_.03_2
0-96
____.21
_F_
_22A-tp
j.q58
38.02
0.00
__588
_301 0
0
__258
-17,
__637
0
61
c)AED e)cursion
836
70
Envelope loss/gain
11422
10390
1258
655
12
a) Infiltration
2825
774
231
63
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
2100
900
Subtotal (lines 6 to 121)
14247
13263
1490
1618
Less e)dennal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
14247
13263
1490
1618
15
Duct loads
23%
35%
3246
4685
23%1
35%1
339
572
1 1
Total room load
1
1
17493
17949
1
1
1829
2
Air required (cfm)
800
800
84
Calculations arwroved bvACCA to meet all reauirements of Manual J 8th Ed.
, -Ofi- wrights-oft- 2018-May-07 14:44:39
AeUk Right -Suite@ Universal 2017 17.0.08 RSU08101 Page I
E;\Documnets\Wrightsoft HVAC\THI EL RES I D ENC E. rup Calc=MJ8 FrontDoorfaces: N
wrightsoft Right-M Worksheet Job:
Entire House Date: May 07, 2018
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Emall: QUICKCALCS@AOL.COM
I
2
3
4
5
Room name
E)posed wall
Room height
Room dimensions
Room area
WIC 2
10.3 ft
8.0 ft heat/cool
1.0 x 30.0 R
30.0 ft2
BATH
10.0 ft
8.0 ft heat/cool
10.0 x 5.0 ft
50.0 ft2
TY
Construction
number
U-value
(I3tuh/ftk-*F)
Or
HTIVI
(13tuh/ft2)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Area (ft-)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/PIS
Heat
Cool
6
11
V1
G
13A4ocs
2 glazing, cir low-e
2 glazing, cIr low-e
11DO
-2gIazing,,cIrjovv_-e---
13A-4ocs
2_qlazina,SIr - lo"__
13A-4ocs
2 glazing, cIr low-e
2 glazing, cIr low-e
.2.glazing,-clr_low,-q_
13A-4ocs
2 glazing, cIr low-e
f6A;3CFmd-'------'-
--O.VO
0.143
0.290
0.290
0.390
-04�
-----0.290-
0.143
0.290
0.1,V3
0.290
0.290
-___0.290
0. 143
0.290
-0=
- -ii
ne
ne
ne
no
' -ie-
se
s
s.
S-W
sw
sw
W-
w
w
4.00
8.12
8.12
io.��Z
4--.00
---8.12
4.00
____8.12
4.00
8.12
8.12
-�.12
4.00
8.12
38.02
-2-9
_2.1
2.19
18.74
18.74
_10.34
19
17.69
2.19
-8-75.
2.19
16.89
17.69
17.69
2.19
24.53
--_-0.00
b
0
0
0
.-- 40
0
_-O
43
0
0
-0
0
0
--- -----0
-6
0
0
0
40
--- -- -- 0
0
-0
43
0
0
0
0
0
------- It
-_10
b
0
0
0
160
- __o
0
0
1-72
0
0
0
0
393
0
0
0
0
88
---,o
0
0
W--
.0
0
0
0
-0
-6
0
0
0
80
0
0
0
0
0
0
0
50
6
0
0
0
0
'80
------------ 0
0
A
o
0
0
0
0
---Yi
10
o
0
0
0
320
0
-6
0
0
0
0
380
0
0
0
175
0
-0
0
0
0
0
0
0
t-G
C
F
22A-tph_____
1.358
30
6
c)AEID e)cursion
-8
-81
Envelope loss/gain
741
213
719
214
12
a) Infiltration
b) Room ventilation
143
0
39
0
138
0
38
0
13
Internal gains: Occupants @ 230
Appliances/other
0
0
0
0
0
0
Subtotal (lines 6 to 13)
885,
252
857
252
14
15
Less odernal load
Less transfer
Redistribution
Subtotal
uc oads
23%
35%
0
0
202
0
0
U
252
89
23%1
35%j
0
0
0
857
1951
0
0
0
252
89
Total room load
Air required (cfm)
1086
50
34
5
Ill
1053
8
4 1
340
151
Calculations approved bVACCA to meet all requirements of Manual J 8th Ed.
-Of+- vv.,ightscfV 2018-May-07 14:44:39
Right -Suite(@ Universal 2017 17.0.08 RSU08101 Page 2
EADocurnnets\Wrightsoft HVAC\THIEL RESIDENCE.rup Calc = M.18 Front Door faces: N
wrightsoft Right-J@ Worksheet Job:
Entire House Date: May 07, 2018
QUICK CALCS, INC. By:
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM
I
Room name
SITTING ROOM
M WIC
2
3
EVosed wall
Room height
26.3 ft
8.0 ft heat/cool
0 ft
8.0 ft heat/cool
4
5
Room dimensions
Room area
1.0 x 173.5 ft
173.5 f?
1.0 x 34.6 ft
34.6 ft2
TY
Construction
number
U-value
(BtuWft2.-*F)
Or
HTM
(Btuh/ft)
Area (ft')
or perimeter (ft)
Load
(Btuh)
Area (ft-)
or perimeter (ft)
Load
(13tuh)
Heat
Cool
Gross
NOS
Heat
Cool
Gross
N/P/S
Heat
cool
6
-J�A
13A-4ocs
2 glazing, cir low-e
0.143
0.290
ne
ne
4.GO
8.12
2.19
18.74
123
15
89
0
355
122
Q
-19,4
281
-0
0
0
0
0
0
0
0
0
I'l
�__a
V
t=G
2 glazing, cIr low-e
11DO
1A-466-i- --' ' ---
-2.glazing,-clr-low-e----
13A-4ocs
0.290
0.390
-- --- 0-143
0*290
0.143
ne
ne
--se--
se
s
8.12
10.92
-----4.0-0
8.12
4.00
18.74
10.34
2.19
17.69
2.19
0
20
88
-0
0
0
20
88
0
0
0
213
352
-0
0
0
202
193
- 0
0
0
ol
0
--0--
0
0
0
0
0
0
0
0
0
0
0
- 0
-0
0
2 qiazinq,_clr low-e-_
13A-4ocs
0.290
0.143
_s
sw
8.12
4.60
____8.75
2.19
0
0
...... 0_.
-0
__0_
0
- -- --- 0
0
_______O
0
__0
0
_9
0
0
2 gjaz!ng cir I -e
2 g azing: cIr loww-e
-2.gtazing, �clr low.:p
0.290
0.290
---Q.290
sw
sw
_svv
8.12
8.12
----8.,12
16.89
17.69
----17.69
0
0
----0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
T-G
13AAocs
2 glazing, cIr low-e
0.143
0.290
w
w
4.00
8.12
2.19
24.53
0
0
-0
0
0
------0
0
0
0
0
0
0
--_-0
0
0
----q
0
0
-0
0
0
_226-
-Q.Q32
1.358
�:Q
38.02
--Z24
0.00
4
- 9
174
49
26
--44
1001
-7
---.109
0
35
31
77
6
c)AED excursion
-35
-2
Envelope loss/gain
2087
944
31
75
12
a) Infiltration
365
100
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
2452
1043
31
75
Less e)demal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
23
20
14
Subtotal
2452
1043
54
95
Duct loads 1
23%
35%
559
369
23%
35%
12
341
r15
Total room load
1
3016
1412
66
129
Ar required (cfm)
1
138
631
1
1
31
6
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed.
, -Pk -,.,Iight�scft- 2018-May-07 14:44:39
ACZk Right -Suite@ Universal 2017 17.0.08 RSUD8101 Page 3
E:kDocumnets\Wrightsoft HVACkTHIEL RESIDENCE.rup Calc = MJ8 Front Door faces: N
wrightsoft Right-J@ Worksheet Job:
Entire House Date: May 07, 2018
QUICK CALCS, INC. By:
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax: 772466-6796 Emall: QUICKCALCS@,AOL.COM
I
Room name
AHU
M BATH
2
Exposed wall
0 ft
13.0 ft
3
Room height
8.0 ft heat/cool
8.0 ft heat/cool
4
5
Room dimensions
Room area
1.0 x 27.2 ft
27.2 ft2
1.0 X 66.0 ft
66.0 ft2
TY
Construction
U-value
Or
HTIVI
Are, (ft2)
Load
Area (ft2)
Load
number
(BtulVft2-*F)
(Btuhift2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(13tuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
3k-45
f ��- -
13A4ocs
2 glazing, cIr low-e
� ------ Q143
0.143
0.290
ne
ne
--4A
4.00
8.12
2.19
18.74
0
0
-6
0
0
-----0--
0
0
-- 0---.
-0
0
-0
-0
0
------- 0
_6
0
b
0
1*1
2 glazing, clr low-e
-11D0--
13A-4ocs
2 glazing, -clr,low-e---
13A-4ocs
0.290
0.390
Ob
---.0.290-se-
0 ' 143
ne
-.ne
S6-
s
8.12
10.92
-4-16
8.12
4.00
18.74
10.34
-21-9
--- 17.69
2 * 19
0
0
0
0
0
0
_0
0
0
0
0
- ------- 0
0
_-O_
0
0
0
_0
0
0
0
-�2-
__ 0
72
0
0
- :��
__0
66
0
0
---- --- 1-:96
__.,__O
266
0
0
-'--1d
0
145
17-G
�=G-
2 alazing. clr Io1w-e_
13A-4ocs
0.290
0.143
__s _
sw
8.12
4.00
_.8.75
2.19
_O�
0
__O
0
0
b
0
0
-6
0
47
0
50
0
2 glazing, cIr low-e
2 glazing, cIr low-e
.2.glazing,Slr
0.290
0.290
___9.290
sw
sw
_Aw,.
8.12
8.12
__- 8.12
16.89
17.69
----17.69
0
0
Q
0
0
_---,O
0
0
0
0
0
---Q
0
0
- -0
0
0
___0
0
0
_--A
0
0
-- 0
13A-4ocs
cir low-e
0. 143
0.290
w
w
4.00
8.12
2.19
24.53
0
0
0
0
0
0
0
0
0
0
0
0-
0
0
0
_��gja;;i�g,
4.
-A6
--- 69
-'----146
-
-,E--
_22A-jRk___
--_!_.358
38..012
-OX
0
--,-0.
------ 0
---o'
- �
--0
0
6
c)AED excursion
-2
-15
Envelope loss/gain
24
59
500
399
12
a) Infiltration
0
0
180
49
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
01
0
subtotal (lines 6 to 13)
24
59
1
680
448
Less extemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
-24
-59
0
0
14
subtotal
0
0
680
448
15
Duct loads
23%
35%
0
0
23%
35%
155
158
Total room load
0
0
835
606
Air required (cfm) 1
0
0
1
-1
381
271
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed.
Aft-Ij vvrightsaft' 2018-May-07 14:44:39
FF Right-SuiteO Universal 2017 17.0.08 RSU08101 Page 4
EADocumnets\Wrightsoft HVAC\THIEL RESIDENCE.rup Calc = MJ8 Front Door faces: N
wrightsoft Right-J@ Worksheet Job:
Entire House Date: May 07, 2018
QUICK CALCS, INC. By:
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
LIVING
STPdRS UP
2
Bposed wall
53.4 ft
12.6 ft
3
Room height
8.0 ft heat/cool
17.9 ft heat/cool
4
5
Room dimensions
Room area
1.0 x 344.5 ft
344.5 ft2
1.0 x 62.0 ft
62.0 ft2
TY
Construction
U-value
Or
HTIVI
Area (ft2)
Load
Area (ft2)
Load
number
(Btu[Vft2.-*F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (fi)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
�13A-4ocs
2 glazing, cIr low-e
0.143
0.290
ne
ne
4.06
8.12
2.19
-2.-19
18.74
--i29
0
--0-
114
0
456
0
0
24§
0
_0
228
0
-:i28
0
---- --- 9�f2�
0
----77
0
498
0
1�
�g
IL13A-4ocs
a
2 glazing, cIr low-e
11DO
2 glazing_qlrjow�e
13A-4ocs
0.290
01390
0.143
0.290
0.143
ne
ne
s�i-
-se -
s
8.12
10.92
----4.00
------ 8.12
4.00
18.74
10.34
2.19
----17.69-
2.19
15
0
0
0
0
0
0
0
0
125
0
0
0
289
0
�0
0
0
0
0
0
0
0
b
0
0
0
___0
0
0
0
A
0,
0
2_aiazinQ.-clr-low-e-___
13A-4ocs;
__,0.290.__s
0. 143
sw
---8.12
4.00
2.19
109
----0
§4
0
�Ti
0
266
0
b
-0
0
0,
0
0
-0
2 glazing, cir low-e
2 glazing, clr low-e
.2.glazing,sl� low-e.---
0.290
0.290
0.290
sw
sw
--sw.
8.12
8.12
---- 8.12
16.89
17.69
17.69
- I ---
0
15
I------- 0
0
2.
0.
- - -- -
0
118
0
-.-- -
0
258
----,o
0
0
0
0
----p
0
0
0
0
0
t13A-4ocs
-G
2 glazing, clr low-e
0.143
0.290
w
w
4.00
8.12
2.19
24.53
190
80
109
0
437
653
239
0
0
0
0
0
0
0
0
(f
-1b
-
----- Q.90
-4
_ZZ
-1972....----
772
-1-6
-
776
-17.1
F
221:
'ttph
-38.02
0.00
0
-W
0
0
0
-7
------ - ---
6
c) AED excursion
816
-25
Envelope loss/gain
2476
4801
1579
644
12
a) Infiltration
738
202
393
108
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
01
Subtotal (lines 6 to 13)
3214
5003
1972
752
Less wdennal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
3
53
49
14
Subtotal
3217
5011
2025
801
5
uctloads 1
23%1
35%1
7.33
1770
230/c
35%
461
283
Total room load
I
1
1
3950
6781
T
2487
1083
Ar required (cfm)
181
302
114
48
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wright:saft, 2018-May-07 14:44:39
Right -Suite@ Universal 2017 17.0.08 RSU08101 Page 5
EADocumnets\Wrightsoft HVAC\THIEL RESIDENCE.rup Calc = M.18 Front Door faces: N
wrightsoft, Right-JO Worksheet Job:
Entire House Date: May 07, 2018
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FIL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM
I
Room name
KITCHEN
MASTER BEDROOM
2
Bposed wall
11.7 ft
32.2 ft
3
Room height
8.0 ft heat/cool
8.0 ft heat/cool
4
5
Room dimensions
Room area
1.0 x 184.5 ft
184.5 ft2
1.0 x 213.0 ft
213.0 ft2
TY
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(BtuIVft2L*F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
13A-4ocs
2 glazing, cir low-e
0.143
0.290
ne
ne
--
4.00
8.12
2.19
18.74
0
0
0
0
0
- 0
0
0
0
0
0
-,0
114
0
-0
98
0
--Q
393
0
-.0
215
0
1�
2 glazing, cIr low-e
11 DO
0.290
0.399
ne
8.12
10.92
18.74
10.34
0
0
0
0
0
0
0
0
16
0
0
0
125
0
289
0
G
13A-4ocs
-2.glazing,-qlr,lox-e--
13A-4ocs
0.143
-_-----0.290
0.143
--ne
se
se�_
s
4.00
__,__8.12
4.00
2.19
_17.69
2.19
0
----0
0
----0
0
0
---,0--
0
0
0
144
0
129
0
517
122
0
282
.265
0
1=0
2 plazinq,_clr low-e_.
_0.290
0.143
_ s__
sw
8.12
4.00
_8.75
2. 19
94
85
33g
0
0
0
0
--0
0
h13A-4ocs
2 glazing, cir low-e
2 glazing, cIr low-e
2,gIazing,jcILIqw-e--_-
0.290
0.290
_____9.290
sw
sw
__AW
8.12
8.12
..... 4AZ
16.89
17.69
_17.69
9
0
___O
2
0
--Q
73
0
_____o
152
0
0
0
�---.--O
0
0
-----0
0
0
0
-6
0
0
-------0
T-G
13A-4ocs
2 g!azing, cir low-e
0 143
0,290
w
w
4.00
8.12
ilb
24.53
0
0
0
0
0
0.
01
0
0
0
6
0
0
6
0
--16A-30md
6.632
-0-.-90'
--3-8.0-2
---Z-"24-
J&
21-j
21-9
--1-9-1
4-17
0.06
--d
0
0
0
0
0
0
0
-T-
6
c)AED excursion
8
40
Envelope loss/gain
5T7
758
1347
1568
12
a) Iryfiltration
162
44
445
122
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
01
0
0
Appliances/other
1200
0
Subtotal (lines 6 to 13)
739
2003
1
1792
1690
Less e)dernal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
9
21
48
29
14
Subtotal
748
2024
1840
1719
15
Duct loads 1
23%
35%
170
715
23%
35%
419
Toted room load
I
9181
27391
2259
2327
Air required (cfm)
1
1
42
122
1
1
103
104
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
411- wriiight:saft, Right-SuiteS Universal 2017 17.0.08 RSUD8101 2018-May-07 14:44:39
E:\Documnets\Wrightsoft HVACXTHIEL RESIDENCE.rup Calc = MJ8 Front Door faces: N Page 6
wrightsaft, Right-J@ Worksheet Job:
Entire House Date: May 07, 2018
QUICK CALCS, INC. By:
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM
1
2
3
4
5
Room name
Bposed wall
Room height
Room dimensions
Room area
M CLST
2.2 ft
8.0 ft heat/cool
1.0 X 10.5 ft
10.5 ft2
TY
Construction
number
U-value
(Btuh/fl:2�-*F)
Or
HTIVI
(Btuh/ft2)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Area
or perimeter
Load
He -at
Cool
Gross ,
N/PIS
Heat
Cool
Gross
N/PIS
Heat
Cool
6
1�
V[5
bx-
13A-40cs
2 glazing, clr low-e
2 glazing, cIr low-e
11DO
13A-4ocs
2 glazing, jcIr lowne
13A-4ocs
2 qIazina,-cIr-lqx-e-
13A-4ocs
2 glazing, clr low-e
2 glazing, clr low-e
-2glazing,clrjaw��--
13A-4ocs
2 glazing, clr low-e
16 d----
-A 143
0.143
0.290
0.290
0.390
0.143
0.290
0.143
-jl*290-
0.143
0.290
0.290
-_____0.290
0.143
0.290
P-M2
ne
ne
ne
ne
se
se-
s
s-
sw
sw
sw
AW-
w
w
-4-.0-0
4.00
8.12
8.12
10.92
4.00
8.12
4.00
--8*-12
4.00
8.12
8.12
8.12
4.00
8.12
-z-fg
2.19
18.74
18.74
10.34
2.19
17.69
2.19
_ 8,75
2.19
16.89
17.69
17.69
2.19
24.53
0
0
0
0
0
-0
0
_-O.
0
0
0
_01-
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
39
0
0
0
0
0
-- 0
0
-0
0
0
0
0
0
-24
----- --
---------
_D
T---G-
t-G
C
-7
6
c)AED excursion
-2
Envelope loss/gain
81
60
12
a) Infiltration
b) Room ventilation
31
0
8
0
13
Internal gains: Occupants @ 230
Appliances/other
0
0
01
Subtotal (lines 6 to 13)
112
69
14
15
Less e)demal load
Less transfer
Redistribution
Subtotal
Duct loads
23%
35%
0
0
-112
0
0
0
0
-69
0
0
I
Totad room load
Ar required (cfm)
0
0
01
0
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed.
wrlght:s-oft- Right -Suite@ Universal 2017 17.0.08 RSU08101 2018-May-07 14:44:39
ACC,P, E:\Documnets\Wrightsoft HVAC\THIEL RESIDENCE.rup Calc = MJ8 Front Door faces: N Page 7
wrightsoft Duct System Summary
Entire House
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Ernall: QUICKCALCS@AOL. COM
For: THIEL RESIDENCE, MEL-RY CONSTRUCTION
10725 S OCEAN DRIVE, JENSEN BEACH, FL
External static pressure
Pressure losses
Available static pressure
Supply/ return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
1.00
in H20
0
in H20
1.00
in H20
0.500 / 0.500
in H20
1.000
in/100ft
800
cfm
Job:
Date: May 07, 2018
By:
Cooling
1.00 in H20
1 0 in H20
1.00 in H20
0.500 / 0.500 in H20
1.000 in/100ft
800 cfm
166 ft
Name
Design
(Btuh)
Htg
(cfm)
Cig
(cfm)
Design
FR
Diam
(in)
HxW
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Eqv
Ln (ft)
Trunk
BATH
h 1053
48
15
1.000
4.0
Ox 0
VlFx
25.3
135.0
st4
BEDROOM 2
C 2190
84
98
1.000
7.0
Ox 0
VIFx
22.8
135.0
st4
KITCHEN
C 2739
42
122
1.000
7.0
Ox 0
VIFx
13.4
115.0
stl
LIVING
C 3390
90
151
1.000
8.0
Ox 0
VIFx
14.0
115.0
st3
LIVING -A
C 3390
90
151
i.boO
8.0
OX0
VIFx
11.8
115.0
st3
• BATH
h 835
38
27
1.000
5.0
Ox 0
VlFx
17.1
115.0
sti
• WIC
C 129
3
6
1.000
4.0
Ox 0
VlFx
16.4
115.0
stl
MASTER BEDROOM
C 2327
103
104
1.000
7.0
Ox 0
VlFx
17.5
115.0
stl
SITTING ROOM
h 3010
138
63
1.000
6.0
OX0
VIFx
26.6
135.0
st4
STAIRS UP
h 2487
114
48
1.000
6.0
Ox 0
VIFx
4.0
95.0
WIC 2
h 1086
50 1
15
1 1.000
1 4.0
1 Ox 0
VlFx 1
31.1 1
135.0
1 st4
Trunk
Htg
Cig
Design
Veloc
Diam
HxW
Duct
Name
Type
(Cfm)
(cfm)
FR
(fpm)
(in)
(in)
Material
Trunk
st2
Peak AVF
319
191
1.000
914
8.0
0 X 0
VinIFIx
st4
Peak AVF
319
191
1.000
914
8.0
0 X 0
Vin[Fix
st2
sti
Peak AVF
186
259
1.000
585
9.0
0 X 0
Vin[Fix
st3 I
Peak AVF
1 181
1 302
1 1.000
1 684
1 9.0
1 0 X 0
VinIFIx
I
2018-May-07 14:44:40
wrightsoft, Right -Suite@) Universal 2017 17.0.08 RSU08101 Page 1
E:\Documnets\Wrightsoft WACkTHIEL RESIDENCE.rup Calc = MJ8 Front Door faces: N
I Return Branch Detail Table
Name
Grill
Size (in)
Htg
(cfm)
CIg
(cfm)
TEL
(ft)
Design
FIR
Veloc
(fpm)
Diam
(in)
HxW,
(in)
Stud/Joist
Opening (in)
Duct
Mati
Trunk
rb4
Ox 0
800
800
0
0
0
0
Ox 0
VIFx
2018-May-07 14:44:40