Loading...
HomeMy WebLinkAboutTRUSSMiTek RE: J36062 - Thiel Res. Lumber design Values are in accordance with ANSI/TPI 1 section 6.3 J These truss designs rely on lumber*,_akb.-_q e-,,A lisebVy 9; CQ A N N, w , F I L BY Site Information: Customer Info: Mel-Ry Construction Project Name: Lot/Block: 103 Subdivisic Address: Lot 103 Nettles Island,,. City: Port St. Lucie State: FL. Name Address and License # of Structural Eng Name: Address: City: M!Tek USA, Inc. 6904 Parke East Blvd. iel Res. Model: Tampa, FL 33610-4115 Nettles Island of Record, If there is one, for the building. ense #: General Truss Engineering Criteria & Design Loads (individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Des�tign Program: IVETek 20/20 8.2 Wind Code: ASCE 7-10 (All HeighH Wind Speed: 170 mph Roof Load: 55.0 psf. Floor Load: 55.0 psf This package includes 71 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G 15-31.003, section 5 of the Florida Bo*d of Professional Engineers Rules. I.No. I Seal# I Truss Name I Date No. Seal# Truss Name I Date 11 T1 4251765 1 A01 G 16/8/18 118 IT14251782 A18 16/8/18 12 IT14251766IA02 16/8/18 119 IT14251783IA19 16/8/18 13 1 T1 4251767 1 A03 16/8/18 120 1 T1 4251784 1 A20 16/8/18 14 1 T1 4251768 1 A04 16/8/18 121 1 T1 4251785 1 A21 16/8/18 15 T1 4251769 1 A05 16/8/18 122 1 T1 4251786 1 A22 16/8/18 16 TI 4251770 1 A06 16/8/18 123 1 T1 4251787 1 A23 16/8/18 17 1 T1 42517711 A07 16/8/18 124 1 T142517881 B01G 16/8/18 18 IT142517721 08 16/8/18 125 1 T1 4251789 1 FG 15 16/8/18 19 IT142517731 09 16/8/18 126 1 T1 4251790 1 FG22 16/8/18 110 IT142517741 10 16/8/18 127 1 T1 42517911 FG23 16/8/18 1 ill IT14251775JAll 16/8/18 128 1 T1 4251792 1 FL1 2 16/8/18 112 1 T1 4251776 1 Al 2 16/8/18 129 1 T1 4251793 1 FL1 4 16/8/18 1 113 1 T1 4251777 1 Al 3 16/8/18 130 IT142517041FL16 16/8/18 1 114 IT14251778IA14 16/8/18 131 1 T1 4251795 1 FL1 8 16/8/18 1 115 1 T1 4251779 1 Al 5 16/8/18 132 1 T1 4251796 1 FL1 8A 16/8/18 116 IT1425178OIA16 16/8/18 133 1 T1 4251797 1 FL1 8B 16/8/18 1 117 IT14251781IA17 16/8/18 134 1 T142517981 FL18C 16/8/18 The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by East Coast Truss. Truss Design Engineer's Name: Finn, Walter My license renewal date for the state of Florida is February 28, 2019. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TP1 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. J%J1111111111"'t R P E IV No 22839 STATE OF Z A*` I N Z V 41, ;4 Walter P. Finn PE No.22839 MrFek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: June 8,2018 Finn, Walter 1 of 2 RE: J36062 -Thiel Res. Site Information: Customer Info: Me[-Ry Construction Project Name: Thiel Res. Model: Lot/Block: 103 Subdivision: Nettles Island Address: Lot 103 Nettles Island, . City: Port St. Lucie State: FL. INo. I Seal# iTruss Name I Date 135 1 T1 4251799 1 FLI 8D 16/8/18 136 1 T1 4251800 1 FU 8E 16/8/18 137 1 T1 42518011 FU 9 16/8/18 1 138 IT142518021FL19A 16/8/18 1 139 1 T1 4251803 1 FL21 16/8/18 140 1 T1 4251804 1 FL22 16/8/18 141 1 T1 4251805 1 FL22A 16/8/18 142 IT142518061FL22B 16/8/18 143 1 T1 4251807 1 FL22C 16/8/18 144 1 T1 4251808 1 FL22D _I 16/8/18 145 1 T1 4251809 1 FL22 E 16/8/18 1 146 IT142518101FL22F 16/8/18 1 147 1 T1 4251811 1 FL23 16/8/18 148 1 T1 4251812 1 FL23A 16/8/18 149 1 T1 4251813 1 FL3 16/8/18 1 150 IT142518141FL7 16/8/18 1 151 !T142518151FL9 16/8/18 1 152 1 T1 4251816 1 ZCJ1 16/8/18 1 153 1 T1 4251817 1 ZEJ 1 A 16/8/18 1 154 1 T1 4251818 1 ZEJ I B 16/8/18 1 155 1 T1 4251819 1 ZEJ 1 C 16/8/18 1 156 TI 4251820 1 ZEJ 1 D 16/8/18 157 T14251821 I ZEJ2 16/8/18 158 1 T1 4251822 1 ZEJ2A 16/8/18 159 1 TI 4251823 1 ZEJ2B 16/8/18 160 1 T1 4251824 1 ZEJ2C 16/8/18 161 1 T1 4251825 1 ZEJ2D 16/8/18 162 1 T1 4251826 1 ZEJ3 _I 16/8/18 163 T1 4251827 1 ZEJ3A 16/8/18 164 T1 4251828 1 ZEJ3B 16/8/18 165 1 T1 4251829 1 ZEA 16/8/18 166 1 T1 4251830 1 ZEAA 16/8/18 167 1 T1 42518311 ZEAB 16/8/18 1 168 1 T1 4251832 1 ZEJ4C 16/8/18 1 169 1 T1 4251833 1 ZEJ5 16/8/18 1 170 1 T1 4251834 1 ZEJ9 16/8/18 171 1 T1 4251835 1 ZHJ3 16/8/18 2 of 2 Job Truss Truss Type i Qty let Res. Thiel Res. �J36062 �AOIG �Ply T1 4251765 Roof Special Girder 1 1 � Job Reference (optional) East Coast I russ, m. Flierce, FL - 34946, 5-1-5 94-2 5-1-5 4-2-13 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:38:59 2018 Page 1 ID:15v_oaxuPHUsRz5LSGfsyhz93ub-qaGpJmjK2�._sWBN07XH?ZL1_6sj73FD2baSsEgz8PgQ 4-2-13 5-11-1 Scale = 1:31.5 NAILED 4X4 zz NAILED NAILED 5.00 F12 2 18 19 NAILED 1.77 [12 1i 3X6 3x4 3x8M18SHS 4X4 = NAILED IX4 11 NAILED Special NAILED NAILED NAILED NAILED TRUSS DESIGNED FOR MWFRS ONLY, PER BUILDING DESIGNER REQUEST. TYPICAL IN THIS JOB. 5-1-5 9-4-2 13-6-15 18-9.5 5-1-5 4-2-13 4-2-13 5-2-6 Plate Offsets (X,Y)- rl:0-0-6,0-0-01.[5:0-5-2,0-0-01,[5:0-0-8,2-2-41.[5:0-0-0.2-11-11I LOADING (psf) SPACING- 2-0-0 CS1. DEFIL. in (10c) I/defi Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.67 Vert(LL) 0.45 6-7 >519 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.75 Vert(CT) -0.49 6-7 >482 180 M18SHS 244/190 BCLL 0.0 Rep Stress Incr NO WEI 0.62 Horz(CT) 0.09 5 n/a n/a BCDL 10.0 Code FBC20171TPI2014 Matrix -MS Weight: 80 lb FT=O% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-8-2 oc purlins. 2-5: 2x4 SP 2850F 1.8E BOTCHORD Rigid ceiling directly applied or 3-8-4 oc bracing. BOTCHORD 2x4 SP 285OF 1.8E *Except* 1-8:2x4 SP No.1 WEBS 2x4 SP No.3 WEDGE Right: 2x4 SP No.3 REACTIONS. (lb/size) 1=1434/0-6-0,5=1299/1-0-0 Max Horz 1=-91(LC5) Max Uplift 1=-902(LC 8). 5=-964(LC 5) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-3087/2066.2-3=-2915/1998, 3-4=-4368/3119, 4-5=-513813778 BOTCHORD 1-9=-1 732/2779, 7-9=-2957/4305, 6-7=-3661/5071, 5-6=-3661/5071 WEBS 2-9=-683/1040, 3-9=-1 62211262, 3-7=-1 61/303, 4-7=-783/795 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf, h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 1=902, 5=964. 8) "NAILED" indicates 3-1 Od (0.148"x3") or 2-12d (0.148"x3.25") toe -nails per NDS guidlines. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 307 lb down and 244 lb up at 5-1-5 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plo Vert: 1-2=-90. 2-5=-90, 10-13=-20 VValter P. Finn PE No.22839 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: .Itjnp A 2nis Cnnfini,prl nr� n- 9 AWARNING - Verify design p.rannaters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312016 BEFORE USE. Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and Is for an individual building component, not Met a truss system. Before use, the building designer must verify the applicability of design parameters and prop er'y Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSI1TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa. FL 36610 Job russ Truss Type Qty Ply Thiel Res. T1 4251765 AOIG IJ36062 T - Roof Special Girder 1 Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:38:59 2018 Page 2 ID:15v_oaxuPHUsRz5LSGfsyhz93ub-qaGpJmjK2�_sWBN07XH?ZL1-6sj73FD2baSsEgzBPgQ LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 2=-62(B) 8=-21 (B) 9=-339(B) 17=-3(B) 1 8=-81 (8) 1 9=49(B) 20=11 7(B) 23�1 O(B) 24=-O(B) 25=7(B) ,& WARNING - V-111Y design Parameters and READ NOTES ON)IHIS AND INCLUDED MITEK REFERENCE PAGE 11,111-7473 re, 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek' fabrication, storage. delivery, erection and bracing oftrusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and SCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa, Fl- 36610 Job Truss Truss Type City Ply Thiel Res. J36062 A02 Roof Special I Job Reference (optional) T1 4251766 East Coast Truss, Ft. Pierce, FL - 34946, 8.220 s May 24 2018 MiTek Industries, Inc. I'd Jun 8 07:39:00 2018 Page 1 6-5-14 ID:15v-oaxuPHUsRz5LSGfsyhz93ub-ImpBX6jykH-NoXzJ5-WotEX44G2AofKBqECPm6z8PgP 6-5-14 14-5-12 22-5-10 e2:4-7 7-11-14 7-11-14 .1'_1 2 Scale = 1:37.8 c9 4x8 M18SHS :=: 5.00 F12 2 3X4 46 3x8 M18SHS IX4 3x8 6-5-14 14-5-12 -10 6.5-1 4 7-11-14 8 — .9 LOADING -(PSD SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.98 Vert(LL) 0.50 5-7 >559 240 MT20 2441190 TCDL 15.0 Lumber DOL 1.25 BC 0.82 Verl(CT) -0.64 5-7 >439 180 M18SHS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.82 Horz(CT) 0.11 4 n1a n/a BCDL 10.0 Code FBC2017frPI2014 Matrix -AS Weight: 95 lb FT = 0% LUMBER- BRACING- UHURD 2xff SP No.2 Except TOPCHORD Structural wood sheathing directly applied. 3-4: 2x6 SID No.2, 2-3: 2x4 SID No.1 BOTCHORD Rigid ceiling directly applied. BOTCHORD 2x4 SP No.1 WEBS I Row at midpt 3-7 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1257/0-6-0, 4=131410-6-5 Max Horz 1 �91 (LC 5) Max Uplift 1 =659(LC 8), 4=-875(LC 5) FORCES. (lb) -,Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-2556/1337,2-3=-241311314, 3-4�4580/2796 BOTCHORD 1-7=-1 115/2300, 5-7=-2659/4479, 4-5�2666/4469 WEBS 2-7=-313/629, 3-7�2309/1703, 3-5=0/283 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3. , Opsf,, h=24ft; B=45ft; L=24ft; eave=4ft; Cat. il; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas Where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 1=659,4=875. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. A WARNING - Verify de�ign Parameters and READ NOrES ON THIS AND INCLUDED MI . rEK REFERENCE. PAGE 11,111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(b connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of indiVidual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314� Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Dart 8634 6904 Parke East Blvd. Timpa'FIL 33610 Date: MiTek' 6904 Parke East Blvd. Tampa, FL 36610 June 8,2018 Job truss Truss Type Qty Ply Thiel Res. J36062 A03 Roof Special T14251767 lob Reference (optional) lerCe, 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:01 2018 Page 1 L ID:15v—oaxuPHUsRz5LSGfsyhz93ub-mzNZkSkaVb6EQhYWfj1 1QS4[pgNxX3BL2uxzJYz8PgO 3 ;15 22-4-11 M-1�3 2-7-3 J_E_ . — r77 3X8 =� 2.5o F-12 4XG zz 1.77112 5X5 = — 5x5 = Scale = 1:39.4 4x6 Z- 23-5-3 20-5-3 224-11 23-0-11 6-74 1-11-8 7-10-7 &2-15 .0411 - LOADING (pso SPACING- 2;0 CS]. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 5 .�O TC 0.79 Vert(LL) 0.35 7-8 >795 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25, BC 0.85 Vert(CT) -0.48 7-B >583 180 M18SHS 2441190 BCLL 0.0 Rep Stress Incr I WB 0.97 Horz(CT) 0.21 6 n/a n1a BCDL 10.0 Code FBC2017ITP12C Matrix -AS Weight: 108 lb FT 0% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied. BOTCHORD 2x4 SO No.1 *Except* BOTCHORD Rigid ceiling directly applied. - 7-9: 2x4 SP No.2, 6-7: 2xG SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1268/0-8-0.6=1310/0-8-0 MaxHorz 1=109(LC7) Max Uplift I =-664(LC 8), 6=-694(LC 5) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD -1-2=-4187/2190, 2-3=-2566/1364, 3-4=-2493/1373. 4-5=-3675/2124, 5-6=-3652/2045 BOTCHORD 1-11�1969/3843, 10-11=-1903/3677, 8-10�1961/3601, 7-8=-1771/3095,6-7�1834/3342 WEBS 2-11 =-253/644, 2-1 0=-1 370/841, 3-1 0=-413/796, 4-1 0�1 344/998, 5-8=-319/523, 5-7=-147/477 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=l 70mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpl=O.l 8; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 1, 6 considers parallel to grain value using ANSIrrPl I angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except at=lb) 1=664,6=694. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Walter P. Finn PE No.22839 MliTek USA, Inc. FL Cert 6634 69(kj Parke East Blvd. Tampa Fl. 33610 Date: June 8,2018 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCEPAGE 11111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrussas and truss systems. see Xa ANSUTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Ale ndria, VA 22314. Tampa, FL 36610 Job T' Truss Type Qty Thiel Res, J36062 rAOUIS S �Roof Special � 1 1 T14251768 I �Ply Job FReference (optional) East Coast Truss, Ft. Pierce, FL - 34946, 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:02 2018 Page 1 ID:15v — oaxuPHUsRz5LSGfsyhz93ub-E9xyyolCGvE52r7iDPZGyfcRS3kFGbSUHYhWr?z8PgN 22;5-7 J.. 44-:1L58 7-8-14 il 1 Scale = 1:39.5 4X8 M 1 8SHS ::z 1.77 �L 3 19 20 5.00 F1_2 5X5 3X4 3X4 2 5 a 10 9 7 6 3 ch 6 6x8 M18SHS 4x8 5X8 M18SHS 16 5x5 3x8 2.5o F1_2 3xB ::z 23-5-15 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/defi Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1. 25 TIC 0.92 Vert(LL) 0.34 9-10 >837 240 MT20 244/190 TCDL 15.0 Lumber DOL I ' 25 BC 0.79 Vert(CT) -0.48 8-9 >583 180 M18SHS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.67 Horz(CT) 0.26 6 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -AS LUMBER- BRACING- TOPCHORD 2x4 SP No.2 *Except* TOP CHORD 3-4: 2x4 SP No.1 BOTCHORD BOTCHORD 2x4 SP No.1 *Except* WEBS 6-7: 2x6 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1271/0-8-0.6=1313/0-8-0 Max Horz 1=135(LC7) Max Uplift I �666(!_C 8), 6=-688(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-4390/2263,2-3=-2638/1406, 3-4=-2516/1367, 4-5=-3365/1782, 5-6--'-3775/1953 BOTCHORD 1-10�2014/4039,9-10=-1933/3864,8-9=-1483/3134, 7-8=-1647/3352, 6-'7�1696/3437 WEBS 2-1 0=-347/795, 2-9=-1 509/903, 3-9�310/737, 4-9=-891/540, 4-8=-1 73/504, 5-8=-271/227, 5-7=-226/372 Weight: 107 lb FT = 0% Structural wood sheathing directly applied. Rigid ceiling directly applied. 1 Row at micipt 4-9 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. [I: Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; encl�vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 1, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except ot=lb) 1=666,6=688. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied 61rectly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. VValter P. Finn PE No.22839 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: June8,2018 ,A WARNING -Verify desig.p.ratneters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. b is always required for stability and to prevent collapse with possible personal Injury and property damage. For genera al temporary and permanent bracing uilding design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Addition ff Design valid for use only with MiTekO connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall and truss systems, see ANSfITPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. fabrication, storage, delivery, erection and bracing oftrusses I guidance regarding the MiTek' Safety Information available from Truss Plate institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.1 Tampa, FL 36610 Job ITruss ITruss Type I City 1ply I Thiel Res. J36062 ' IA05 lRoof Special 1 1 � Job Reference (optional) T14251769 East Coast Truss, Ft. Pierce, FL - 34946. 8.220 s May 24 2018 MiTek Industries, Inc. Fd Jun 8 07:39:03 2018 Page 1 ID:15v-oaxuPHUsRz5LSGfsyhzg3ub-iLVK98mqlCMyf_ium64Wt9f TlL?3[dWCQ4NRz8PgM 6-7-8 14-2;4 1�6_ Y 2 �2 �11, 6-7-8 44-f 4. 1-0-7 0 ob 4 Scale= 1:39.7 1.77 Lv- 4X4 � 3 18 19 5X5 zz 4x8 ::� 2.5 0 F1 _2 Us zz 23-6-11 6-7-8 0-7-1 14-24 1 1 22-" V3-62:,3 -7-8 T 0_, 2V471 5.11-9 6 4- c4 6 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) Ildefl Lid PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.75 Vert(LL) 0.38 8-9 >742 240 MT20 2441190 TCDL 15.0 Lumber DOL 1.25 BC 0.99 Verl(CT) -0.55 7-8 >513 180 M18SHS 244/190 BCLL 0.0 Rep Stress Incr YES VV13 0.61 Horz(CT) 0.31 6 n/a n/a BCDL 10.0 Code FBC2017rrP[2014 Matrix -AS Weight: 107 lb FT 0% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied. BOTCHORD 2x4 SP No.2 *Except* BOTCHORD Rigid ceiling directly applied. 6-7: 2x6 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 REACTIONS. (lb/size) 1=1275/0-8-0,6=1316/0-8-0 Max Horz 1=160(LC7) Max Uplift 1�668(]_C 8), 6=-690(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-4333/2203,2-3=-2554/1365,3-4=-2383/1323,4-5�3894/2167,5-6=-3937/1987 BOTCHORD 1-9=-1928/3979,8-9=-1851/3813,7-8=-1136/2582,6-7=-1701/3589 WEBS 2-9=-357/859,2-8=-1640/980,3-8=-490/964, 4-8=-430/219, 5-7=-380/358. 4-7=-848/1469 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=D.l 8: MWFRS (directional); cantilever left and fight exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 1, 6 considers parallel to grain value using ANSIrrPI 1 angle to grainformula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 1=668,6=690. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Walter P. Finn PE No.22839 MiTek USA, Iric. FL Cert 6634 6004 Parke East Blvd. Tampa FL 33610 Date: June 8,2018 ,& WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTelk(D connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall Nil' building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrussos and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 _F__ Job ITruss ITruss Type Qty Ply Thiel Res. J36062 I A06 il�oof Special 1 1 � Job Reference (optional) T1 4251770 East Coast Truss, Ft. Pierce, FL - 34946, 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:04 2018 Page I ID:[5v—oaxuPHUsRz5LSGfsyhz93ub-AY3iMTnSoWUpHBG5Kqbk24iogtRTkUunIsAdvtz8PgL TL12 8-7& 11-9-11 el=7;�7 1iL3-" L2�7;10 23-7-7 _11_1 2 '4 1-D-7 I Scale = 1:39.9 4x6 = 3x8 ::�: 2.50 F1_2 3X8 Zz 8-7-8 23-7-7 B-7-8 14-7.7 22-7-0 �11-ib 7-11.9 LOADING (psf) SPACING- 2-0-0 CS1. TCLL 30.0 Plate Grip DOL 1.25 TC 0.88 TCDL 15.0 Lumber DOL 1.25 BC 0.74 BCLL 0.0 Rep Stress Incr YES WB 0.72 BCDL 10.0 Code FBC2017rrPI2014 Matrix -AS LUMBER- TOPCHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.2 *Except* 1 -8: 2x4 SP No.1, 6-7: 2x6 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1278/0-8-0,6=1320/0-8-0 Max Horz 1�181(LC6) Max Uplift 1�670(1_C 8), 6=-692(LC 8) DEFL. in (loc) I/defl Ud PLATES GRIP Vert(LL) 0.48 7-8 >587 240 MT20 2441190 Vert(CT) -0.67 7-8 >423 180 Hor,z(CT) 0.34 6 n/a n/a Weight: 108 lb FT = 0% BRACING- TOPCHORD Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-4519/2399,2-3=-3905/1965,3-4=-3927/2126, 4-5=-3501/1788,5-6=-4155/2195 BOTCHORD 1-8=-2147/4176. 7-8=-91412273, 6-7=-1920/3820 WEBS 2-8=-599/514, 3-8=-393/312, 4-8=-998/.1888, 4-7=-637/1339, 5-7=-668/581 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=1 70mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL= , �.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18: MWFRS (directional); cantilever left and right exposed ; en� vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 1, 6 considers parallel to grain value using ANSIrlPI 1 angle to grainformula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 1=670,6=692. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Walter P. Finn PE No.22839 MiTek USA, Iftc. FL Cart 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: June 8,2018 ,&WARNiNG-Verfrydesig.p.rameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid fof use only with MirekG connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only� Additional temporary and permanent bracing is always required for stability and to prevent co [lapse with possible persona I injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 A I Job Truss Truss ype Qty Ply Thiel Res. I J36062 A07 Roof Special 1 . T14251771 lob Reference (optional) I - ­1 . � - ­­' u.zzu a may Z4 ZU18 Mi I eK Industries, Inc. FriJun 807:39:052018 Pagel 5-7-12 ID:15v_oaxuPHUsRz5LSGfsyhz93ub-ekd4apn5ZqcgvlrHuX6zalEOPHmhT-9wzWvASKz8PgK 10-7-8 17-2-14 22-7-12 L3-8 3 5-7-12 4-11-12 111 �21�0 1 5-4-13 5-4-13 _.--7 Scale = 1:40.7 4x6 = IX4 11 4 3 5.00 F1_2 �3x,4 Z�- 3X4 2 6XB 8 SX5 '0 7 1 10 7 lX4 11 x 6 17 5x5 2z: 3X8 2.50 F12 3x8 Zz 23-8-3 22-7-12 i3_'l 54-13 0_8_'! LOADING (pso TCLL 30.0 TCDL 15.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/TP12014 CS1. TC 0.69 BC 0.80 WB 0.53 Matrix -AS DEFL. in Vert(LL) 0.44 Vert(CT) -0.62 Horz(CT) 0.35 (loc) I/defl L/d 9-10 >652 240 9-10 >455 180 6 n/a n/a PLATES GRIP MT20 244/190 Weight: 109 lb FT 0% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied. BOTCHORD 2x4 SP No.1 *Except* BOTCHORD Rigid ceiling directly applied. 8-9: 2x4 SP No.2, 6-7: 2x6 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1282/0-8-0,6=1323/0-8-0 Max Horz 1 =-1 82(LC 6) Max Uplift 1 =-672(LC 8), 6=-693(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2�4483/2296, 2-3=-3509/1759, 3-4=-3457/1869, 4-5=-3261/1640, 5-6=-4026/2058 BOTCHORD 1-1 0=-2035/4130, 9-1 0=-2042/4146, 8-9=-1 057/2646, 7-8=-1 811/3726, 6-7=-1 786/3686 WEBS 3-9=-3761234, 4-9=-737/1379, 4-8=-462/991, 5-8=-822/584, 2-9=-971/666 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=.3.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all area� where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 1, 6 considers parallel to grain valu6 using ANSIrrPI I angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 1=672,6=693. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Walter P. Finn PE No.22839 MiTak USA, Inc. FL Cert 8634 604 Parke East Blvd. Tampa FL 33610 Date: June 8,2018 A WARNING -Vefify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERENCi PAGE 11711.7473rev� 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is, for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the M!Tek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Qu - it , AJaxandria, VA 22314. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Su a 312 ality Criteria,* DSB-89 and BCSI Building Component 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss ype Qty Y —_ Thiel Res. ;4�9 J36062 A08 Roof Special �Pl I T14251772 7JobReference (optional) aSL �OM I rUSS, Ft. Pierce, FL - 34946, 8.220 s May 24 2018 MITek Industries, Inc. Fri Jun 8 07:39:05 2018 Page I ID:15v_oaxuPHUsRz5LSGfsyhz93ub-ekd4apn5ZqcgvlrHuX6zaIE?fHjcTx3wzWvASKz8PgK 6-3-3 11-10-7 17-3-7 99-A.7 P 6-3-3 5-7-4 5-5-0 5-5-0 3X8 ::r 4x6 = 1 3 Scale = 1:40.1 3x8 Zz 6-3-3 23-8-15 234-8 B-3-3 f —i LOADING (psf) SPACING- 2-0-0 CS1. TCLL 30.0 Plate Grip DOL 1.25 TC 0.73 TCDL 15.0 Lumber DOL 1.25 BC 1.00 BCLL 0.0 Rep Stress Incr YES WB 0.72 BCDL 10.0 Code FBC2017/TP12014 Matrix -AS LUMBER- TOPCHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.2 *Except* 1-7: 2x4 SP No. 1, 5-6: 2x6 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1285/0-8-0, 5=1327/0-8-0 Max Horz 1�182(LC6) Max Uplift 1 =673(LC 8), 5=-695(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-4464/2278, 2-3=-3307/1640, 3-4=-316011576, 4-5�4043/2054 BOTCHORD 1-8=-2009/4109, 7-8=-2014/4124. 6-7=-1801/3734, 5-6=-1778/3699 WEBS 2-7�1 173/779, 3-7=-87211898, 4-7=-951/631 CP T 6 DEFL. in (loc) I/defl Ud PLATES GRIP Vert(LL) 0.44 7-8 >646 240 MT20 2441190 Vert(CT) -0.64 7-8 >447 180 M18SHS 244/190 Horz(CT) 0.36 5 n/a n1a Weight: 103 lb FT = 0% BRACING- TOPCHORD Structural wood sheathing directly applied BOTCHORD Rigid ceiling directly applied. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf,, BCDL=3.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areag where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 1 7) Bearing at joint(s) 1, 5 considers parallel to grain value using ANSIfTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 1 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 1=673,5=695. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cert 6634 $904 Parke East Blvd. Tampa FL 33610 Data: June 8,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with Mi7ekO connectors. This design is based only upon parameters shown, and ls�for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall buildingdesign. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. I Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSI/TPH Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. 6904 Parke East Blvd. Tampa, FL 36610 Job T ss Truss Type Qty �Ply 1 �.Thiel Res. T1 4251773 J36062 A09 — Roof Special Job 'eference (optional) East Coast Truss, Ft. Pierce, FL - 34946, 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:06 2018 Page I 6-3-6 11-10-13 ID:]5v_oaxuPHUsRz5LSGfsyhz93ub-7wBSn9ojK7kXWSQTSFdC7VngKh2nCOH4CAfk—mz8PgJ 6-3-6 17-4,1 17-0-4 9A 11 5-7-7 5-5-3 5-5-3 1,20-8 Scale = 1:40.2 4x6 3 5.00 F12 3X4 i:�- 3X4 2 4 7 6 8 M18SHS 1 8 IX4 11 5 5X5 �z 17 2.50 F1-2 3x8 3x8 ZZ 2349-11 LOADING (PS9 SPACING- 2-0-0 CS1. DEFL. in (10c) I/defi Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC, 0.74 Vert(LL) 0.44 7-8 >644 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 1.00 Vert(CT) -0.64 7-8 >445 180 M18SHS 2441190 BCLL 0.0 Rep Stress Incr - YES WEI 0.73 Horz(CT) 0.37 5 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -AS Weight: 104 lb FT 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied. BOTCHORD 2x4 SP No.2 *Except* BOTCHORD Rigid ceiling directly applied. 1-7:2x4 SP No.1, 5-6:2x6 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1289/0-8-0,5=1330/0-8-0 Max Horz 1=-183(LC6) Max Uplift 1 =-675(LC 8), 5=-697(LC 8) FORCES. (ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-4478/2285, 2-3=-3316/1645, 3-4=-3169/1581, 4-5=-405712061 BOTCHORD 1-8=-2015/4122, 7-8=-2020/4138, 6-7=-1 807/3747. 5-6=-1 785/3712 WIEBS 2-7=-1 177/782, 3-7=-875/1904, 4-7=-955/634 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=�.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; en� vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Dpsf on the bottom chord in all areati where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 1, 5 considers parallel to grain value using ANSIfTPI I angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except ot=lb) 1=675,5=697. 9) This truss design requires that a minimum of 7116" structural wood sheathing be applied, directly to the top chord and 1/2" gypsum sheetrock be applied directly to the boftom chord. Walter P. Finn PE No,22839 MiTek USA, Ifi6 FL Cart 6634 6904 Parke East Blvd, Tampa FL 33610 Data: June 8,2018 AWARNING - Varifj�hfeslgn parameters and READ NOTES ON THIS AND INCLUDED MtTEKREFERENC� PAGE Mll-7473 rev� 1010312015 BEFORE USE. Design valid for use only with NIrrek(E) connectors. This design is based only upon parameters shown, and is�for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and prop6rly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of indi' v1dual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the Welk' fabrication, storage, delivery, erection and bracing oflrusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 21 8 N. Lee Street, Suite 312, Alexandra, VA 22314� 6904 Parke East Blvd. Tampa, FL 36610 Job T' ss Truss Type City Ply Thiel Res. J36062 TA 1u) R oof Special T1 4251774 �Job I Reference (ootional) Godst Truss, Ft. Pierce, FL - 34946, 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:07 2018 Page I ID:15v—oaxuPHUsRz5LSGfsyhz93ub-b7kr?VpL5RsN8c?g?y8RqKKz4S9xrUDRqOHWCz8PgI r,3-9 11-11-3 17-4-9 22-10-0 F 7 6-3-9 5-7-10 5-5-6 5-5-6 ii. IT08 4x6 = i — I 6.3-9 i Scale = 1:40.3 N LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/defi Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.75 Vert(LL) 0.44 7-8 >648 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.74 Vert(CT) -0.64 7-8 >449 180 M18SHS 244/190 BCLL ' 0.0 Rep Stress Incr YES WB 0.73 Horz(CT) 0.36 5 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -AS Weight: 104 lb FT 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied. BOTCHORD 2x4 SP No.1 *Except* BOTCHORD Rigid ceiling directly applied. 5-6: 2x6 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1292/0-8-0, 5=1334/0-8-0 Max Horz 1�183(!_C 6) Max Uplift 1 �677([_C 8), 5=-699(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2�4493/2292, 2-3=-3326/1650, 3-4=-3179/1586, 4-5=-406612066 BOTCHORD 1-8=-2022/4136, 7-8=-2027/4151, 6-7�181313757, 5-6�1789/3721 WEBS 2-7=-1 182/785, 3-7=-878/1911, 4-7=-957/636 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf, h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=O.l 8; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4). Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 1, 5 considers parallel to grain value using ANSIrrPI 1 angle to grain iormula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Gt=lb) 1=677,5=699. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Walter P. Finn PE No.22839 MiTek USA, In ' 6. FL Cart 6634 6 904 Parke liast Blvd. Tampa Fl. 33610 Date: June 8,2018 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 rev. 1010212015 BEFORE USE. Design valid for use only with MiTekaD connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and prop6dy Incorporate this design Into the overall Nil' building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to collapse MiTek' prevent with possible personal Injury and property damage. For general guidance regarding the . fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quaility Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314: 6904 Parke East Blvd. Tampa, FL 36610 East Coast Truss, Ft. Pierce, FIL - 34946, 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:08 201B Page 1 ID:15v—oaxuPHUsRz5LSGfsyhz93ub-3J[DCrqzsLEmmasZgfgCwsVdUoLgl!NfU8r2ez8PgH r,3-12 11-11-9 7'5-2 6-3-12 5-7-13 _-91 2 R:61 3 1. �." .8 i 3xit ::: 4x6 = Scale = 1:40.4 3x8 zz &3_12 i 1_11� 17-5-2 22-10-12 23-11-3 6-3-12 L i M 5-7-13 5-5-9 LOADING (pso SPACING- 2-0-0 CS1. TCLL 30.0 Plate Grip DOL 1.25 TC 0.75 TCDL 15.0 Lumber DOL 1.25 BC 0.74 BCLL 0.0 Rep Stress Incr YES WEI 0.73 BCDL 10.0 Code FBC2017/TPI2014 Matrix -AS LUMBER- TOPCHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.1 *Except* 5-6: 2x6 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1296/0-8-0,5=1337/0-8-0 Max Horz 1 �1 84(LC 6) Max Uplift I �679([_C 8). 5=-701 (LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-4507/2299,2-3=-3335/1654, 3-4�'3188/1590, 4-5�4080/2073 BOTCHORD 1-8�2028/4149, 7-8=-2034/4164, 6-7=-1819/3770, 5-6�1795/3733 WEBS 2-7=-1 187/788, 3-7=-881/1917, 4-7=-961/638 �2 DEFL. in (loc) I/defl Ud PLATES GRIP Vert(LL) 0.44 7-8 >646 240 MT20 244/190 Verl(CT) -0.64 7-8 >47 180 M18SHS 244/190 Horz(CT) 0.36 5 n/a n1a Weight: 104 lb FT = 0% BRACING- TOPCHORD Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with a . ny other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 1, 5 considers parallel to grain value'using ANSI/TPI I angle to grain formula. Building designer should verify Capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) except at=lb) 1=679,5=701. 9) This truss design requires that a minimum of 7116" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 1311 ' 34 6904 Parke East Blvd. Tampa FL 33610 Data: June 8,2018 AWARNING -Verify design pammeters, and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGEM11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with M17ek9 connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall Dal' building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Nexandria, VA 22314. 6904 Parke East Blvd. Tampa, FL 36610 Job Tr S 'us T Truss Type Qty Ply Th jet R s. J36062 TA 1u2s FR..fsSpyecial jai 1 T1 42 FRefeerence Job (optional) East Coast Truss, Ft. Pierce, FL - 34946. I 3X8 :::: Plate Offsets (X,Y)— T1:0-0-9,Edoel. [5:0-4-0.0-2-0 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:09 2018 Page I ID:15v_oaxuPHUsRz5LSGfsyhz93ub-XVsbQBqbd265Nv927NBvl8PgHu8XPIwWu8tOb5z8PgG L7, L2- ?L;.1 1-'151 1 ';28 A�A = Scale = 1:40.6 3X8 zz 23-11-15 4 6 LOADING (pso TCLL 30.0 TCDL 15.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0. Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/TP]2014 CS1. TC 0.76 BC 0.74 WB 0.73 Matrix -AS DEFL. in Vert(LL) 0.45 Vert(CT) -0.65 Horz(CT) 0.36 (loc) I/def! Ud 7-8 >643 240 7-8 >445 180 5 n/a n/a PLATES MT20 M18SHS Weight: 105 lb GRIP 244/190 244/190 FT 0% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied. BOTCHORD 2x4 SID No.1 *Except* BOTCHORD Rigid ceiling directly applied. 5-6: 2x6 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1299/0-8-0,5=1341/0-8-0 Max Horz 1=-184(LC 6) Max Uplift 1 =-681 (LC 8), 5=-702(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2�4522/2307, 2-3=-334511659, 34�3197/1595, 4-5=-4094/2081 BOTCHORD 1-8�2035/4162, 7-8=-2040/4178, 6-7�1 825/3783, 5-6=1 802/3746 WEBS 2-7=-1 192/791, 3-7=-883/1923, 4-7�9651641 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10: Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf, h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 pelf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 1, 5 considers parallel to grain value using ANSlrrPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 1=681,5=702. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the boftom chord. Walter P. Finn PE No.22839 MiTek UU, Inc. FL Gel 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: June 8,2018 ,&WARNING,- Verify design paramefers and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use onlywith MiTekO connectors. This design isbased onlyupon parameters shown, and Isforan individual building component, not atrusssystem. Before use, the building designer must verify the applicability of design parameters and property incorporate this design intotheoverall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see 8 ANSUTP11 Quafity Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Inforntatlon available from Truss Plate Institute, 21 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa. FL 36610 Job Truss Truss Type Qty Thiel Res. A13 Roof Special 1 �Ply 1 T14251777 � Job Reference (optional) St ! russ. Fl. Pierce, FL - 34946, 8.220 s May 24 2018 MITek Industries, Inc. Fri Jun 8 07:39:10 2018 Page I ID:15v—oaxuPHUsRz5LSGfsyhz93ub-?hQzdXrDOMFy?3kEh5l8HLyrvlUi8C8f7odx7Xz8PgF 6-4-2 12-0-5 17-& 6-4-2 i �5 �24-0-12 5-8-3 5-5-1 07; 11 1 1-0-8 3X8 ':: 4x6 = Scale = 1:40.6 3x8 z= 64-2 11-10.1 i 234)-4 24-0-12 216- �=— H 6-4-2 5-5-15 1. i 5-9-15- g 6 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deff Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.77 Vert(LL) 0.45 7-8 >641 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.75 Vert(CT) -0.65 7-8 >444 180 M18SHS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.73 Horz(CT) 0.37 5 n1a n1a BCDL 10.0 Code FBC2017fTP]2014 Matrix -AS Weight: 105 lb FT 0% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied. BOTCHORD 2x4 SP No.1 *Except* BOTCHORD Rigid ceiling directly applied. 5-6: 2x6 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=130310-8-0, 5=1344/0-8-0 Max Horz 1 �1 85(LC 6) Max Uplift 1 =-683(LC 8). 5=-704(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-2=4536/2314, 2-3=-3354/1664, 3-4=-3207/1599, 4-5�4108/2088 BOTCHORD 1-8=-2041/4176, 7-8=-2047/4191, 6-7�1831/3795, 5-6=-1808/3759 WEBS 2-7�1 1961794, 3-7=-88611928, 4-7�970/644 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf, h=24ft; B=45ft; L=24ft; eave=4ft; Cat. H; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and fight exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 1, 5 considers parallel to grain value using ANSIfTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) except at=lb) 1=683,5=704. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Walter P. Finn PE No.22839 MiTek USA Irit FL Ced 6634 6904 Farke'�asi Blvd. Tampa Fl. 33610 Date: June8,2018 ,& WARNING - Verify design parameters and READ NO TES ON THIS AND INCLUDED MITEK REFERENCE PA GE M11-7473 rev. 101031201S BEFORE USE. Design valid for use only with MiTekO connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability ofdesign parameters and property Incorporate this design into the overall MY buildingdesign. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For, general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 East Coast Truss, Ft. Pierce, FL - 34946, 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:11 2018 Page 1 ID:15v—oaxuPHUsRz5LSGfsyhz93ub-Tu—Lqtss9gNpdDJREoDNqZU?FiomtbbpMSMVfzz8PgE 6-4-5 120 11 4 19-0-13 i i 2: i I �24-1-8 6-4-5 -8-6 2_7-4 4-4-14 -0-10 Scale= 1:41.8 46 = 3X8 2x4 11 48 3X4 :-4-5 11-10-7 14-8-0 19-0-13 239-0 8 '8-3 6-4-5 5-E Plate Offsets (X,Y,)— [11 10-0-9,Edgel, [7:0-3-8.0-2-01, [9:0-5-8.0-3-81, [10:0-2-4.0-3-81 4-4-14 4 144-6 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl - Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.79 Vert(LL) 0.44 10-11 >665 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.85 Vert(CT) -0.63 10-11 >459 180 EICLL 0.0 Rep Stress Incr YES WEI 0.91 Hor'z(CT) 0.34 6 We rile BCDL 10.0 Code FBC2017rrPI2014 Matrix -AS Weight: 114 lb FT=O% LUMBER- BRACING. TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied. BOTCHORD 2x4 SP No.2 *Except* BOTCHORD Rigid ceiling directly applied. 1-10: 2x4 SP No.1, 4-8: 2x4 SP No.3 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1306/0-8-0,6=1348/0-8-0 Max Horz 1=-186(LC6) Max Uplift 1 =-684(LC 8), 6=-706(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-4560/2327, 2-3=-3339/1655, 3-4�3120/1610, 4-5�38i&1948, 5-6=-2599/1365 BOTCHORD 1-1 1�2054/4198, 10-11=-2059/4213, 9-10�1555/3525, 4-9�158/323, 6-7=-1 146/2318 WEBS 2-10=-1210/819, 3-10�956/2007,4-10�745/455, 5-7�924/529, 7-9�11 i96/2396, 5-9=-391/1138 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf-, h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas'where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) I considers parallel to grain value using ANSIITPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 1=684,6=706. 8) This truss design requires that a minimum of 7/16" stru ctural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: June 8,2018 AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rov� 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Tr ss pe City Thiell Res. I ,TA 1u, �'RrouosfsSpacial I �Ply T14251779 TJob ob R Reference (optional) 6 ; Gua5i Tru5s, Fit. Pierce, FL - 34946, 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:12 2018 Page 1 ID:15v_oaxuPHUSRz5LSGfsyhz93ub-x4Yk2DtUvzVgFNudoVkcMmlAu57Yc2oya662BQz8pgD 6-4-8 12-1-1 14-8-12 19-1-9 �4-�-41 6-4-8 5-8-9 2-74, 4-4-14 5_,_l , I 4X6 = 3x8 2x4 4X8 3X4 Scale = 1:41.9 17 9 6-4-8 11-10-13 1 4-8 2 i 12 1 19-1-9 23-9-12 2 -2r 6-4-8 _9_ �4 4-4-14 Plate Offsets (X,Yl— Tl:0-0-9,Edgel, [7:0-3-8.0-2-0 1. [9:0-5-8.0-3-81, 1`10:0-2-4.0-3-81 LOADING (Psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defi Lid PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.80 Vert(LL) 0.44 10-11 >662 240 MT20 2441190 TCDL 15.0 Lumber DOL 1.25 BC 0.85 Vert(CT) -0.64 10-11 >457 180 BCLL 0.0 Rep Stress Incr YES WEI 0.92 Horz(CT) 0.34 6 n/a n1a BCDL 10.0 Code FBC2017rrPI2014 Matrix -AS Weight: 114 lb FT 0% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied. BOTCHORD 2x4 SP No.2 *Except* BOTCHORD Rigid ceiling directly applied. 1-10: 2x4 SP No.1, 4-8: 2x4 SP No.3 WEBS 2x4 SP No.3 REACTIONS. (lb/size) I = 1309/0-8-0, 6=1 351/0-8-0 Max Horz 1=-187(LC6) Max Uplift 1 =-686(LC 8). 6=-708(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-4574/2334, 2-3=-3349/1659, 3-4=-3130/1615, 4-5=-3834/1956, 5-6L2607/1369 BOTCHORD 1-11=-2060/4212, 10-11=-2066/4226,9-10=-1563/3541,4-9=-158/322.6-7=-I150/2325 WEBS 2-1 0=-1 215/822, 3-1 O�958/2012, 4-1 0=-750/459, 5-7�927/531, 7-9=-1 200/2404, 5-9=-395/1146 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3LOpsf, h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) I considers parallel to grain value using ANSIITPI I angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) except Jt=Ib) 1=686,6=708. 8) This truss design requires.that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Walter P. Finn PE No.22839 MiTak USA, Inc. FL W 6634 6904 Parke East Blvd. Tampa FL 33610 Date: Jbne 8,2018 ,&WARNING. V.11(yefe.1g.p.rarnefers and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE 16AGEM11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTakO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Befo(e use. the building designer must verifythe applicability of design pa ram eters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing psi' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek' fabrication. storage, delivery, erection and bracing oftrusses and truss systems, see Alaxa ANSTP" Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, ndria, VA 22314. Tampa, FIL 36610 Job Truss Type aty Ply Thiel Res. J36062 A16 �Truss Roof Special 1 T1 4251780 Job Reference (optional) IZaSL CoaSL 1 rUSS, rt. Pierce, FL - 34946, 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:13 2018 Page I ID:15v-oaxuPHUsRz5LSGfsyhz93ub-PG66FYu6gHdXsXSpMDFrv-ZPQVVVLZx6pmrbksz8PgC 1 12-8.3 5-11.2 12 - 18-1-11 '24-34 5­11-2 1 LXV 1_2!12 1 5-5-8 6-1-5 2 1 .08 F1 _2 0-2-15 Scale = 1:43.2 5x5 46 19 4 1� 6 3X4 1x4 11 3x8 3x4 3X4 3X4 12-8-3 5-11-2 1 5-3-5 1-2-120_2_1 5 Z�Iu_B 24,34 5-8-13 OL" Plate Offsets (X,Y)- F3:0-2-8,0-1-21, [6:0-0-10. Edgel LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Well Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.56 Vert(LL) 0.18 7-9 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.74 Vert(CT) -0.29 7-9 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.67 Horz(CT) 0.08 6 We n/a BCDL 10.0 Code FBC2017/TP]2014 Matrix -AS Weight: 115 ib FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 SOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1313/0-8-0,6=1355/0-8-0 Max Horz 1 �1 80(LC 6) Max Uplift 1=688(LC 8), 6=-710(LC 8) BRACING- TOPCHORD Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. , TOPCHORD 1-2=-2715/1440. 2-3=-1 95311103, 34�1 726/1102, 4-5�2594/1566, 5-6=-259511355 BOTCHORD 1-10=-1212/2455,9-10�1212/2455,7-9�65911615,6-7=-1121/2304 WEBS 2-9=-841/570, 3-9=-74/283, 5-7�502/447, 4-9=-145/498, 4-7=-611/942 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=1 70mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. il; Exp D; Encl., GCpi=C.1 8; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 1=688,6=710. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Walter P. Finn PE No.22839 MiTik USA Inc. Fl. Cart 6634 6904 Parke'�ast Blvd. Tampa FL 33610 Date: June 8,2018 AWARNING - VerIfY design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE IiAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with Mi7ekQD connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Nil' is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the MiTek' fabrication, storage. delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, ASexandria, VA 22314. 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Qty Thiel Res. J36062 A17 FRoof Special 1 �Ply 1 T14251781 � Job Reference (optional) 4 -r mci=nes. inc. t-ri jun tl Uf:J9:74 ZU18 Page I ID:15v ...uPHUsR.z.'5'L�S�Gf"s'y.hyz'9�3u'b" u'. a TgUTuukRalOUhlOwwm4RB6aZvqL468F2Qb9Glz8PgB 1-1-2 13-6-12 14-7-12. 19-1-13 24-3-12 41-i 5-5-1b 1-1-0 4-6-2 5-1-15 IScale = 1:41.4 4xr, == 2.08 F1 _2 3.24112 4x6 =:: 4X4 :zz 19 20 4 5 ii 4X4 3X8 U4 = 3x8 4X4 1 8-1-2 Plate Offsets (X,Y)— rfl:0-1-6,Edgel, [7:0-2.2.Edgel LOADING (psf) SPACING- 2-0-0 CS1 DEFL. in (loc) I/deff Lid TCLL 30.0 Plate Grip DOL 1.25 TC 0.53 Vert(LL) 0.18 8-10 >999 240 TCDL 15.0 Lumber DOL 1.25 BC 0.83 Vert(CT) -0.35 8-18 >836 180 BCLL 0.0 Rep Stress Incr YES WB 0.29 Horz(CT) 0.09 7 n/a n1a BCDL 10.0 Code FBC2017fTP12014 Matrix -AS LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD BOTCHORD 2x4 SP No.2 BOTCHORD WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1316/0-8-0,7=1358/0-8-0 Max Horz 1=-145(LC 6) Max Uplift 1=-690(LC 8), 7=-712(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2�2800/1517,2-3=-2358/11284, 3-4=-219211306, 4-5�1940/1184,5-6�2112/1160' 6Z2612/1421 BOTCHORD 1-10�1311/2556,8-10�772/1815,7-8�1194/2335 WEBS 2-1 0=-486/378, 4-8=-1 511470, 6-8�538/424, 4-1 O�248/492 PLATES GRIP MT20 244/190 Weight: 115 lb FT = 0% Structural wood sheathing directly applied. Rigid ceiling directly applied. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=10psf, h=24fl; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end!vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 1=690,7=712. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 2 Walter P. Finn PE No.22839 MlTek USA, Inc. F1 Cott 6034 6904 Parke �as't Blvd. Tampa Fl. 33610 Date: June 8,2018 AINARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTeM connectors. This design isbased onlyupon parameters shown, and Isforan Individual building component. not atrusssystem. Beforeuse,the building designer must verify the applicability of design parameters and properly incorporate this design intothe overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek* fabrication. storage, delivery, erection and bracing of trusses and truss systems, see Safet ANSIITPII Quality Criteria, DSB-89 and BCST Building Component 6904 Parke East Blvd. y Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type City Ply Thiel Res. J36062 TAI 8 Roof Special I T1 4251782 Job Reference (optional) C� ff1 M, 0.44V b IVIdy 44 ZV 10 IVII I eK inousines, Inc. t-n Jun a UI:J9:15 2018 Page I ID:15v oaxuPHUsRz5LSGfsyhz93ub-MfDsgEvMCutF6qcCTeHJ PfgdJgvpWpOG4Kiolz8PgA 4- 3 9-10-0 4-1-3 16-7-4 24-4-C �_11_1 P — I __ i i __1 _"_J, 4-10-3 i _10_, 1-11-0 7-9-4 Scale = 1:41.5 3.24112 2.08 F12_ 4X4 ::n 1920 4 .5 5X6 4X4 3x4 3X8 = 4x4 44 1X4 11 4-11-13 9-8.7 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Lid TCLL 30.0 Plate Grip DOL 1.25 TC 0.90 Vert(LL) 1 -0.20 9-10 >999 240 TCDL 15.0 Lumber DOL 1.25 BC 0.87 : Vert(CT) -0.46 9-10 >632 180 BCLL 0.0 Rep Stress Incr YES WS 0.45 Horz(CT) I 0.09 6 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -AS LUMBER - TOP CHORD 2x4 SP No.2 BOTCHORD 2x4SPNo.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1320/0-8-0,6=1361/0-8-0 Max.Horz 1�128(LC6) Max Uplift 1 �692(!_C 8), 6=-713(LC 8) PLATES GRIP MT20 244/190 Weight: 108 lb FT=O% i BRACING - TOP CHORD Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-2840/1453, 2-3=-264211468, 3-4=-2119/1194, 4-5�2134/1230, 5-6=-2455/1285 BOTCHORD 1-10=1317/2555,9-10=1400/2618, 7-9�11014/2142, 6-7=-101612145 WEBS 2-10�37/279, 3-9=738/634, 4-9=-4001690, 5-9�404/256 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasci * =132mph; TCDL=9.Opsf; BCDL=3.Opsf,, h=24fl; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=O.l 8; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas Where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 1=692,6=713. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Walter P. Finn PE No.22839 MiTek USA, Ine, FL Cert 6634 6904 Parke EastiSlvd, Tampa FL 33610 Date: A WARNING -Verify design parameters andREAD NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(D connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and prop erly incorporate this design into the overall Sol' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek' fabrication. storage, delivery. erection and bracing oftrusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa, FL 36610 I; 6 June 8,2018 Job Tru s rus T Truss Type City Ply Res. J36062 I A19 . ' 1.1 FR.ofsSpyecial 1 TThiel T14251783 Job Job Reference (optional) aS 005L 1 FUSS, rL. muluu, rL. - 34946, 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:16 2018 Page 1 ID:15v — oaxuPHUsRz5LSGfsyhz93ub-qmEuaw zC?6j_BOILpYXcBtSlVzYzIYVk4GKBz8Pg9 8-10-1 15-9-11 18-6-12 24-54 6-11-10 91 6-11-10 5-10-8 5.0 2.08 r1_2 46 = 3.24112 A�A Z! Scale = 1:41.8 3X6 = 1x4 11 4X4 = 3x8 = 3X4 = 3X4 = 1X4 11 B-10-1 15-9-11 1�Z2 24-n-12 24-5 6-11-10 6-11-10 5-16-0 QL4-� 1 41 � � .1 ­­ � — -- LOADING (pso TCLL 30.0 TCDL 15.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC20171TPI2014 CS1. TC 0.76 BC 0.89 WB 0.50 Matrix -AS DEFL. in Vert(LL) 0.35 Vert(CT) -0.44 Horz(CT) 0.11 (loc) Udefl Ud 10 >834 240 9-10 >669 180 6 n/a n/a PLATES GRIP MT20 244/190 Weight: 111 lb FT 0% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 *Except* TOPCHORD Structural wood sheathing directly applied. 2-4: 2x4 SP No. I BOTCHORD Rigid ceiling directly applied. BOTCHORD 2x4 SP No.2 WEBS I Row at midpt 3-9 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1323/0-8-0,6=1365/0-8-0 Max Horz 1=-102(LC6) Max Uplift I �770(!_C 4), 6=-715(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-3179/1888, 2-3=-3968/2351, 3-4=-2411/1325, 4-5=-2396/1346, 5-6�256811344 BOTCHORD 1-11=-1859/2955, 10-11=-1890/2954, S-10=-229113863,7-9=-1106/2270,6-7�1104/2272 WEBS 2-1 0=-498/916, 3-9�1 665/1274, 4-9=-301/572 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3�Opsf, h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right, exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed fore 10.0 psfbofforn chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 1=770, 6=715. 7) This truss design requires that a minimum of 7116" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Walter P. Finn PE N0.22839 MiTak USA, Inc. FL Carl 004 0904 Parke East Blvd. Tampa Fl. 33610 Date: June 8,2018 A WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(D connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and jo prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erect on and bracing ottrusses and truss systems, see ANSIrrPl1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Qty Ply Thiel Res. J36062 A20 Roof Special I T1 4251784 Job Reference (optional) 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:17 2018 Page 1 ID:15v—oaxuPHUsRz5LSGfsyhzg3ub-12Ld5wxckV7zL8mbb3Kn3qk4J6uMHOChkOpptdz8Pg8 8-3-13 15-2-3 12:9-5 22-9-1 B-3-13 6-10-6 3.7-2 3-11-12 3.24 112 4x6 2.08 F12 3x8 � 6X8 11 IX4 11 3x8 M18SHS � 4xB = 1x4 11 Scale = 1:37.9 3X4 = F_7j 91 8-3-13 -7-9 7-8-4 Plate Offsets (X.Y)— [1:0-4-11,0-0-07, 11:0-0-8.1-10-81, fl:0-0-0,2-6-91 15-2-3 6_10-6 18-9-5 9ji LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defi Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25. TC 0.63 Vert(LL) 0.42 9-19 >651 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.68 Vert(CT) -0.48 9 >569 180 M18SHS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.59 Horz(CT) 0.09 5 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -AS Weight: 94 lb FT 0% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 *Except* TOPCHORD Structural wood sheathing directly applied. 1-3: �x4 SP No. 1 BOTCHORD Rigid ceiling directly applied. BOTCHORD 2x4 SP No. 1 *Except* WEBS 1 Row at midpt 2-7 1-8: 2x4 SP 2850F 1.8E WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 REACTIONS. (lb/size) 5=1237/0-8-0, 1=1266/1-0-0 Max Horz 1=108(LC4) Max Uplift 5�648(!_C 8), 1 =-851 (LC 4) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2�4286/2694, 2-3=-2340/1334, 3-4=-2362/1368, 4-5=-2319/1220 BOTCHORD 1-9�2658/4203, 7-9=-2658/4203, 6-7=-1052/2070, 5-6=-1047/2067 WEBS 2-9=0/267, 2-7�2046/1607, 3-7=-245/487, 4-7�166/378 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf,, h=24ft; 8=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated.' 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live -load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 5=648, 1=851. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Miter P. Finn PE No.22639 MiTak USA, Inc. FL Gert 6634 6§04'Parke Eas , I Blvd. Tam . pa FL 33610 Date: June 8,2018 G- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MITek(D connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must vedfy the applicability of design parameters and properly incorporate this design into the overall ME building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSVTPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandra, VA 22314. 6904 Parke East Blvd. Tampa, FL 36610 Job Tru a Truss Type Qly Thiel Res. J36062 A21 Roof Special I Job Reference (optional) V 4 c� o.zzu a may z4 zuits Nil I eK Inoustnes, Inc. Fri Jun 8 07:39:18 2018 Page I 6-8-4 ID:15v_oaxuPHUsRz5LSGfsyhz93ub-mEv9lGxFVpFqz[Ln9mrOcIHG7WCkOp4rz2ZMP3z8Pg7 11-11-2 16-4-4 1-4 6-8-4 i _0 5-2-14 4-5-2 2-1 46 3.24 112 2.08 F1_2 3 M = 1x4 11 4X4 � 4X8 = IX4 11 Scale = 1:30.6 3X4 = 7 V 6 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/defi Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.56 Vert(LL) 0.27 9 >806 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BIC 0.74 Vert(CT) -0.30 7-9 >730 180 BCLL 0.0 Rep Stress Incr YES WEI 0.74 Horz(CT) 0.06 5 n/a n1a BCDL 10.0 Code FBC2017/TPI2014 Matrix -AS Weight: 77 lb FT=O% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied. BOTCHORD 2x4 SP No.2 *Except* BOTCHORD Rigid ceiling directly applied. 1-8: 2x4 S P No. 1 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 REACTIONS. (lb/size) 5=999/0-8-0, 1=1029/1-0-0 Max Horz 1=103(LC4) Max Uplift 5=-547(LC 5), 1=-729(LC 4) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-2�3287/2266, 2-3=-2000/1267, 34=-2009/1278, 4-5�1 755/1006 BOTCHORD 11-9�224813226, 7-9=-2248/3226, 6-7=-910/1598, 5-6=-888/1581 WEBS 2-7�1 39811149, 3-7=-1 89/384, 4-7= -321/448 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd.=132mph; TCDL=9.Opsf: BCDL=3.0psf:, h=24ft; B=45ft; L=24ft; eave=4ft: Cat. 11; Exp D; Encl., GCpi=0.18: MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed fore 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ut=lb) 5=547,1=729. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. I Walter P. Finn PE No.22839 MiTek USA, Inc, FL Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: June 8,2018 ,&WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev� 1010312015 BEFORE USE. Design valid for use only with MiTeke connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see xa ANSIfTPI1 Ctuality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Ale ndria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Thiel Res. J36062 A22 Roof Special 1 1 T14251786 Job Reference (optional) 5-0-12 4x4 = 2.o8 F-2 o.zzu s may z4 zults Nil leK Inaustries, Inc. FriJun 807:39:182018 Pagel ID:15v_oaxuPHUsRz5LSGfsyhz93ub-mEv?lGxFVpFqzlLngmrOclHDwWBCOxVrz2ZMP3z8Pg7 8-8-1 14-1-7 3-7-5 5-5-7 4X4 3 qxq — 3.24112 Scale = 1:22.8 3X4 = 11 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in floc) I/defi Lid PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.76 Vert(LL) 0.15 5-9 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.77 Vert(CT) -0.18 5-9 >954 180 BCLL 0.0 Rep Stress Incr YES WB 0.20 Horz(CT) 0.03 4 n/a n/a BCDL 10.0 Code FBC2017frP[2014 Matrix -AS Weight: 50 lb FT = 0% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied. WEBS 2x4 SP No.3 REACTIONS. (lb/size) - 1=80111-0-0. 4=752/0-8-1 Max Horz 1 =77(LC 4) Max Uplift 1=-566(LC 4), 4=-479(LC 5) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-1890/1452, 2-3=-1320/902, 3-4=-1383/915 BOTCHORD 1-5�1393/18112,4-5=-79811267 WEBS 2-5=-636/662, 3-5=-29/260 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3!Opsf; h=24fl; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 1=566,4=479. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. VValter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 6634 604 Parke East Blvd. Tampa FL 33610 Data: June 8,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Nil' building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication. storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB.89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa, FL 36610 :1 Job Truss ype QtY Ply Thiel Res. J36062 A23 Roof Special Girder 17 T1 4251787 Job Reference (optional) M 5-5-0 2.08 F12- *.44V b lVidy 414 ZU 10 IVII I eK inausines, Inc. i--ri Jun 6 uf:�$V:19 2018 Page 1 ID:15v-oaxuPHUsRz5LSGfsyhz93ub-EQTNWcytG7NhaSwziUMF8FpR7wdq[RE-BilwxWz8Pg6 3-5-8 4X4 � NAILED NAILED 13 2 3.24112 3X4 = 1 3X4 = Scale = 1:16.3 1i 0-7-9 4-9-7 1 .- I � ___P0_1z_T. 3-0-14 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLIL 30.0 Plate Grip DOL 1.25 TC 0.54 Vert(LL) 0.04 4-8 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.43 Vert(CT) -0.04 4-8 >999 180 BCLIL 0.0 Rep Stress Incr NO WEI 0.04 Horz(CT) 0.01 3 n/a n/a BCDIL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 28 to FT = 0% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purfins. BOTCHORD 2x4 SP No.2 WEBS tP BOTCHORD Rigid ceiling directly applied or 8-5-9 oc bracing. 2x4 No.3 REACTIONS. (Ibisize) 1 =535/1-0-0. 3=492/0-8-14 Max Horz 1 =47(LC 4) Max Uplift I =-406(LC 5), 3=-322(LC 5) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 11-2�7118/509, 2-3�733/536 BOTCHORD 1-4=-452/664, 3-4=-460/664 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=O.l 8; MWFRS (directional); cantilever left and right exposed ; end �ertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 to uplift at joint(s) except Ot=lb) 1=406,3=322. -10d (0.148"x3") or 2-112d (0.148"x3.25") toe -nails per INDS guidlines. 7) "NAILED" indicates 3 1 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber lncrease=1.25, Plate Increase=1.25 Uniform Loads (plo Vert: 1-2�90, 2-3=-90, 5-9=-20 Concentrated Loads (lb) Vert: 2=-17(F) 4�27(F) 114�7(1`) Walter P. Finn PE No.22839 MiTek USA, Inc. FL Carl 6 ' 6 ' 34 6904 Parke East Blvd. Tampa FL 33610 Date: AwARN,NG. Vadlyd-ignp....fers and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with Mi7ek0connectom. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For ge'neral guidance regarding the MiTek' fabrication. storage, delivery, erection and bracing of trusses and truss systems, see Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexan ANSI1TPI1 Quality Criteria, DS849 and BCS1 Building Component 6904 Parke East Blvd. dria, VA 22314. Tampa, FIL 36610 June 8,2018 Job S Truss Type Thiel Res. I J36062 �T BOIG Hip Girder �Ply 1 T14251788 � _. Job Referencelootional) u5b, 1-1. Viel­Ce, r-L ­54tl4b, 3-4-8 4x8 � NAILED 2 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:20 20 18 Page 1 ID:15v—oaxuPHUsRz5LSGfsyhz93ub-idlljyzVlQVXCcVAGBtUhSMgdK—oUuU8QM2TTyz8Pg5 5-5-8 8-10-0 2-1-0 3-4-8 Scale= 1: 16.5 Special 4x4 7 ,r 6 2X4 = �peciai 3-4-8 B-5-8 -1, 01 0' 4-8 Plate Offsets (X.Y)— 3-0-0 [2:0-5-0,0-2-01, [4:0-0-2.Edgel 3-0-0 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) Ildefl Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.30 Vert(LL) 0.02 5-6 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25. BC 0.38 Vert(CT) -0.03 5-6 >999 180 BCLL 0.0 Rep Stress Incr NO WEI 0.04 Hor7(CT) 0.01 4 n1a file BCDL 10.0 Code FBC2017frPI2014 Matrix -MS Weight: 34 lb FT = 0% LUMBER - TOP CHORD 2x4 SP NO.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=558/0-4-0, 4=567/0-4-0 Max Horz 1 =52(LC 24) Max Uplift I =-335(LC 8), 4=-346(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-772/491, 2-3=-669/500, 3-4=-790/61 0 BOTCHORD 1-6�368/649, 5-6�368/654, 4-5=-385/665 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 9-5-0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) \Arind: ASCE 7-10; Vult=l 70mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end'vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all area&where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 1 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 1=335,4=346. 8) "NAILED" indicates 3-10d (0.148"xY) or 3-12d (0.148"x3.25") toe -nails per NDS guidlines. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 141 lb down and 296 lb up at 5-5-8 on top chord, and 57 lb down and 39 lb up at 3-4-8, and 57 lb down and 39 lb up 6t 5-4-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-90, 2-3=-90, 3-4=-90, 7-11 =-20 Concentrated Loads (lb) Vert: 2=-23(F) 3�57fl 6=-37(F) 5=-37(F) Walter P. Finn PE No.22839 MiTak USA, Inc. FL Cert 6634 664 Parke East Blvd. Tampa Fl. 33610 Cate: June 8,2018 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTeloO connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M1, is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication. storage. delivery, erection and bracing oftrusses and truss systems, see ANSIfTPl1 Quality Criteria, DSB.89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA22314. Tampa, FL 36610 Truss Type city Ply Thiel Res. Truss 15 FLOOR 1 T1 4251789 3 _.FG Job Reference (optional) ...... 0.44V b lVidy 4-+ ZU 10 IVII I eK inausines, Inc. t- n jun 6 U I ZU 15 Page 1 ID:15v_oaxuPHUsRz5LSGfsyhz93ub-Apb7xH-7okdOql4MquOjEgviQkEuD6JHf?n 1 OOz8Pg4 4-0-0 7-4-1 10-9-7 14-M 4-0-0 3-4-i 1 34-11 4-0-0 Scale = 1:24.5 10 11. 12 9 13 141 8 15 7 7X6 = 16 6 46 = Special Special 7x6 Special 4x8 Special Special Special 46 Special I LOADING (psf) TCLL 40.0 TCDL 10.0 BCLL 0.0 BCDL 5.0 SPACING- 2-0-0 Plate Grip DOL 1.00 Lumber DOL 1.00 Rep Stress Incr NO Code FBC2017rrP[2014 CS1. TC 0.88 BC 0.71 WEI 0.96 Matrix -MS DEFL. in Vert(LL) -0.32 Vert(CT) -0.44 i Horz(CT) 0.02 (loc) Well Ud 8 >528 360 8 >387 240 6 n/a n/a PLATES GRIP MT20 244/190 Weight: 245 lb FT = 0% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 3-11-6 oc purlins, BOTCHORD 2x6 SP SS except end verticals. WEBS 2x4 SP No.3 *Except* BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 1-10,5-6:2x8 SP No.2,1-9,5-7:2x4 SP No.2 REACTIONS. (lb/size) 10=4376/Mechanir-al, 6=4004/mechanical FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-10=-2852/0,1-2=-11393/0,2-3=-14609/0,3-4=14609/0,4-5�11354/0,5-6=-2863/0 BOTCHORD 9-10=0/1537,8-9=0/11393, 7-8=0/11354,6-7=0/1458 WEBS 1-9=0/10182,2-9=-1167/0,2-8=0/3342,3-8=-307/0, 4-8=0/3382, 4-7=-1178/0, 5-7=0/10224 NOTES- 1) 3-plytruss to be connected togetherwith 10d (0.131"x3") nails asfollows: Top chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-6-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Refer to girder(s) for truss to truss connections. 5) Recommend 2x6strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ' 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 985 lb down at 1-0-14, 981 lb down at 3-0-14, 978 lb down at 5-0-14, 974 lb down at 7-0-14, 971 lb down at 9-0-14, and 967 lb down at 11-0-15, and 964 lb down at 13-0-15 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber lncrease=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-5=-100, 6-10=-10 Concentrated Loads (lb) Vert: 7=-967(B) 11 =-985(B) 12=-981 (B) 13=-578(B) 14=-974(B) 15=-971 (B) 16=-964(B) Walter P. Finn PE No.22839 Ii USA, Inc. FL Carl 6634 11904 Parke East Blvd. Tampa FL 33610 Date: June 8,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE �AGEMJI.7473r,, 1010212015 BEFORE USE. Design valid for use only with MiTekQ connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use. the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal injury and properly damage. For1general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS1rrPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Adexandria, VA 22314. Tampa, FL 36610 Job u5s Truss Type Qty Thiel Res. I J36062 TFG22 �FLOOR �ply T14251790 3 G.Z4U b WRAY 44 ZU 10 IVII I eK inaustries, Inc. t-n jun d ut:JU:zz zu18 Page 1 3-8-9 �_J 1_2 12_,_3 ID:Ilv_oaxuPHUsRz5LSGfsyhz93ub-f?8W8d—IZ2]FRvfYOcvymtRt27ZeyczQtrXaYrz8Pg3 15-2-4 184-13 �2_1 -6 3-8-9 2_,_, 2_,_1 3-2-9 _8-, Scale = 1:37.2 3x10 44 1X4 11 1X4 11 44 = 3X4 3x10 4x1O 14x10 2 3 4 5 6 7 8 9 118 3-8-9 1?! 1 16 15 14 13 12 1 1 3-8-9 10 1 3x4 11 5X16 3x4 =3x8 M 1 SSHS = 4x4 4x4 3x4 5X16 3X4 11 Special 3- �_1:2 i ,l_g i � 21-- 9-83 - 2-9:1 12-5- 9-0-1 15.2-4 2-9-1 22-1-6 3-8-9 Plate Offsets (X.Y)— [2:0-1-12,0-1-81, [8:0-1-12,0-1-81, [10:0-2-0,0-2-141, [11:0-7-12.0-3-01, [17:0-7-12.0-3-01,118:0-2-0.0-1-61 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.82 Vert(LL) -0.52 14-16 >495 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.80 Vert(CT) -0.71 14-16 >362 240 M18SHS 244/190 BCLL 0.0 Rep Stress Incr NO WB 0.81 Horz(CT) 0.07 10 n/a n1a BCDL 5.0 Code FBC2017/TP]2014 Matrix -MS Weight: 317 lb FT = 0% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD BOTCHORD 2x4 SP 285OF 1.8E WEBS 2x4 SP No.3 *Except* BOTCHORD 1-18,9-10:2x8 SP No.2,2-17,8-11: 2x6 SP No.2 1-17,9-11,2-16,8-12:2x4 SP No.1 REACTIONS. (lb/size) 18=4593/Mechanical, 10=1767/Mechanical FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-18=-4317/0.1-2=-12609/0,2-3=-13500/0,3-4�11734/0,4-5=11734/0,5-6=-11734/0, 6-8=-8617/0,8-9=-4681/0,9-10=-1687/0 BOTCHORD 17-18=0/540,16-17=0/12794,14-16=0/13500,13-14=0/11734,12-13=0/8617, 11-12=0/5441 WEBS 2-17=-406/96,1-17=0/12714,8-11=-1671/0,9-11=0/4716,2-16=0/749,3-.16=0/341, 3-14=-2608/0, 5-13=-673/0, 6-13=0/3794, 6-12=-1 274/0, 8-12=0/3369 Structural wood sheathing directly applied or 4-9-8 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Special connection required to distribute bottom chord loads equally between all plies. 2) 3-ply truss to be connected together with 1 Od (0.1 31"x3") nails as follows: Top chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc, 2x4 - I row at 0-7-6 oc. Bottom chords connected as follows: 2x4 - 2 rows staggered at 0-4-0 oc. Webs connected- as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. 3) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated, 4) Unbalanced floor live loads have been considered for this design. 5) All plates are MT20 plates unless otherwise indicated. 6) Plates checked for a plus or minus 0 degree rotation about its center. 7) Refer to girder(s) for truss to truss connections. 8) Recommend 2x6strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 3994 lb down at 3-8-7 on bottom chord. The design/selection of such connection d6vice(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber lncrease=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-9�100, 10-18=-10 Concentrated Loads (lb) Vert: 17�3994(B) I& WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERENCE PAGE M11-7473 rev. 101031201S BEFORE USE. Design valid for use only with MiTeks connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTP11 Quality Criteria, DSB-89 and SCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. VValter P. Finn PE No.22839 A�ffek USA, Iric. Fl. Gert 6634 4904 Parke East Blvd. Tampa FL 33610 Date: Nil' MiTek' 6904 Parke East Blvd. Tampa, FL 36610 June 8,2018 Job Us S Truss Type Q ty Thiel Res. J36062 TFG23 F LOOR I �Ply T1 4251791 � . 3 Job Reference (optional) 0.44U5lVldyZ'4ZUIOIVIIIeKinausines,inc. t-niun du(:3U:Z3ZU16 Paqel 3-8-9 3-3-11 1 2-10-3 1 2-10-3 1 2-10-3 ALL CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO EACH PLY OF THE TRUSS. 4x10 3x12 4X4 W 11 IX4 11 3X4 = 4X4 1 2 .3 4 5 6 7 lie 3-8-9 17 16 15 14 13 12 3X4 11 5xl 6 3X8 M1 8SHS 4X4 4X4 44 Special 4x4 = 3-3-11 3-8-9 LOADING (pso SPACING- 2-0-0 CS1. DEFIL. in (loc) Well Ud TCLL 40.0 Plate Grip DOL 1.00 TC 0.93 Vert(LL) -0.59 14-16 >451 360 TCDL 10.0 Lumber DOL 1.00 BC, 0.87 Vert(CT) -0.80 14-16 >330 240 BCLL 0.0 Rep Stress Incr NO WEI 0.87 Horz(CT) 0.07 10 n/a n/a BCDL 5.0 Code FBC2017rrP[2014 Matrix -MS LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD BOTCHORD 2x4 SP 285OF 1.8E WEBS 2x4 SP No.3 *Except* BOTCHORD 1-18,9-10:2x8 SP No.2,2-17,8-11: 2x6 SP No.2 1-17,9-11: 2x4 SP No.1 REACTIONS. (lb/size) 18=4951/Mechanical, 10=1834/Mechanical FORCES. (lb) -Max. Corri Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-18=4656/0,1-2�113639/0, 2-3=-14517/0,3-4�12546/0,4-5�12546/0, 5-7=-12546/0, 7-8=-9098/0, 8-9=-4903/0, 9-1 0�1 757/0 BOTCHORD 17-18=0/576, 16-17=0/1 3817, 14-16=0/1 4517, 13-14=0/1 2546, 12-13=0/bO98, 11-12=0/5707 WEBS 2-17=-386/131, 1-17=0/1 3761, 8-11 =-1 M4/0, 9-11 =0/4951, 2-16=0/740, 3-16=0/372, 3-14=-2858/0, 4-14=0/268, 5-13=-713/0, 7-13=0/4147, 7-12=-1 341/0, 8-12=0/3585 Scale = 1:38.0 3x12 010 8 A ill 3-8-9 10 1 5xl 6 3X4 11 PLATES GRIP MT20 244/190 M18SHS 244/190 Weight: 323 lb FT=O% Structural wood sheathing directly applied or 3-10-14 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) NIA 2) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc, 2x4 - I row at 0-7-b oc. Bottom chords connected as follows: 2x4 - 2 rows staggered at 0-4-0 oc. Webs connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - I row at 0-9-0 oc. 3) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (8), unless otherwise indicated. 4) Unbalanced floor live loads have been considered for this design. 5) All plates are MT20 plates unless otherwise indicated. 6) Plates checked for a plus or minus 0 degree rotation about its center. 7) Refer to girder(s) for truss to truss connections. 8) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 Do and fastened to each truss with 3-1 Od (0. 131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 4366 lb down at 3-8-9 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plo VValter P. Finn PE No.22839 Vert: 1-9=-100, 10-18=-10 MiTek USA, Inc. FL Cart 6634 Concentrated Loads (lb) 6904 Parke East Blvd. Tampa FL 33610 Vert: 17=-4366(F) Date: June 8,2018 ,&WARNING. verify design parameters and READ NOrES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(D connectors. This design is based only upon parametirs shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability ofdesIgn parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web an d/or chord members only. Additional temporary and permanent bracing is always required for stability and to MiTek' prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication. storage, delivery, erection and bracing oftrusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandriia, VA 22314. 6904 Parke East Blvd. Tampa. FL 36610 Job Type 36052 1 FL12 East Coast Truss, Ft. Pierce. FL - 34946, 0-3-6 i 1-3-0 C 5X5 3x3 1 2 I_. 1 IJobReferenre (optional) T1 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:24 2018 Page 1 ID:[5v—oaxuPHUsRz5LSGfsyhz93ub-bOGGZJO?5f?zhDoxVlyQr]XKkxKKQeDjLzOhdjz8Pgi 0-7-3 0.7-12 Scal� = 1: 18.6 3x3 IX4 11 3 4 3X3 3X3 30 5X5 6 7 8 15 14 13 12 11 10 9 3X3 11 3X3 3x3 1X4 11 3X3 3X3 3X3 11 �-3 �&I 1 6-4-9 B-10-9 1-0-4 _6 1 4-7-3 2-6-0 Plate Offsets (X,Y)— [1:0-2-0,Edgel, [8:0-2-O.Edgel LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.36 Vert(LL) -0.03 11-12 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.47 Vert(CT) -0.05 11-12 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.31 Hor'z(CT) -0.01 8 n/a n/a BCDL 5.0 Code FBC2017/TP[2014 Matrix-S Weight: 62 lb FT = O%F, O%E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=542/0-7-8, 1=64210-2-13 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP C ' HORD 1-3=-493/0, 3-4=-1091/0, 4-5=-1091/0, 5-6=-1027/0, 6-8=-506/0 BOTCHORD 13-14=0/900, 12-13=0/1 091, 11-12=0/1 091, 10-11 =0/914 WEBS 8-1 0=0/653, 1-14=0/636, 6-1 0=-57410, 3-14=-573/0, 3-13=0/349 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Provide mechan ical cofin ection (by others) of truss to bearin g plate at joint(s) 1. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss,with 3-1 Od (0.131 X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Can 6634 6904 Parke East Blvd. Tampa FL 33610 Date: June 8,2018 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015BEFORE USE. Design valid for use only with MiTekG) connectors. This design Is based only upon parameters shown, and is eor!an Individual building component, not a truss system. Before use. the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. A�ditional temporary and permanent bracing Is always required for stablifity and to prevent collapse with possible personal Injury and property damage. For g , fabrication, storage, delivery, erection and bracing of trusses and truss systems, see eneral guidance regarding the MiTek' ANSUTPII Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa, FL 36610 Job 'u S Truss Type Clty Thiel Res. J36062 FFL1s4` �Floor [ly T1 42 51793 Job Reference (optional) 0-1-8 H 0-11-6 1-2-13 1-3-0 3x6 = 3x8 1X4 11 3X4 1X4 11 3x3 1X4 11 o.zzu s may z4 zuitj mi I eK Inousines, Inc. Fri Jun 8 07:39:25 2018 Page 1 ID:15v—oaxuPHUsRz5LSGfsyhz93ub-3aqemflesz8qlNN73kTfOW3WwLan9OqtadIE99z8Pgo 0 1' 8 Scale ll.22.5 3x3 1X4 11 3x4 1X4 11 M = M = 2 1� �Xo — JX?J � 3X6 = 3X6 = 3X6 = 3x8 = 3X6 = Plate Offsets (X,Y)— [19:0-1-8,0-1-81, F20:0-1-8,0-1-81 i LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.27 Vert(LL) -0.16 15 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.78 Vert(CT) -0.22 15 >744 240 BCLL 0.0 Rep Stress Incr YES WE 0.61 Horz(CT) 0.04 12 n/a n/a BCDL 5.0 Code FBC2017rrPI2014 Matrix-S Weight: 75 lb FT = O%F, O%E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SR No.2(flat) except end verficals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 18=708/1-0-0,12=732/0-7-4 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. i TOPCHORD 1-1 8=-73610, 11-12�725/0, 1-2�1 098/0, 2-3�1 098/0, 3-4=-2392/0, 4-5�2392/0, 5-6=-2833/0, 6-7=-2833/0, 7-8=-2416/0,8-9=-2416/0, 9-10�1141/0, 10-11=-1141/0 1 BOTCHORD 17-18=01251, 16-17=0/1 839, 15-16=0/2712, 14-15=0/2724, 13-14=0/1 874 WEBS 11-13=0/1275,9-13=-880/0,9-14=0/652, 7-14�37010, 5-16=-385/0,3-16--0/664, 3-17�893/D, 1-17=0/1071 NOTES- 1) Plates checked for a plus or minus 0 degree rotation about its center. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) CAUTION, Do not erect truss backwards. 4) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cert 6634 6004 Parke East Blvd. Tampa FL 33610 Date: June 8,20 AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11711-7473 rev. 1010312015 BEFORE USE. Design valid for use only with Ivn`ek0 connectors. This design Is based only upon parameters shown, and Is for'an individual building component, not a tmss system, Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For gi�neral guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see let ANSIrrPI1 Quality Criteria, DSB.89 and BCSI Building Component Sa y Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. 6904 Parke East Blvd. Tampa. FL 36610 Job ' a Truss-tyrie Qty- Ply Thiel Res. J36062 JFLU1s6 �Floor ��Job T1 4251794 ob Reference (optional) 0-M F--i i 1-3-0 5x5 � 3X3 1 2 1�1 ts.zzu s may Z4 ZU1 U Mi I eX Industries, Inc. Fri Jun 8 07:39:26 2018 Page 1 ID:15v—oaxuPHUsRz5LSGfsyhz93ub-XmOO—?2GcGGhwXyJdS_uxicgjlzMuV3OoHVohcz8Pg? 1-1-15 0712 S.lr_'�V = A.8 3x3 3x3 1X4 11. 1X4 11 3x3 3X3 3x3 = 5x5 3 4 5 a 7 8 in 18 17 16 15 14 13 12 11 3X3 4x4 3x3 3x3 3X3 3X3 4X4 3X3 "3- 1 �9�6 4-3-6 1 0-a-5 5 1 '_5 _3 2-6-0 JMI�0-71�4 Plate Offsets (X,Y)-- [1:0-2-0,Edgel, f10:0-2-02dael LOADING (psfj SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ltd PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.33 Vert(LL) -0.10 14-15 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.63 Verl(CT) -0.14 15 >999 240 BCLL 0.0 Rep Stress Incr YES WEI 0.48 Horz(CT) -0.03 10 n/a n/a BCDL 5.0 Code FBC2017frP[2014 Matrix-S Weight: 83 lb FT = O%F, O%E LUMBER- - I BRACING- '­ ZX4 or 140./kliat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SID No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 10=779/0-7-8, 1=779/0-2-13 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. , TOPCHORD 1-3=-77910, 3-4=-1 788/0, 4-5=-2266/0, 5-6�2266/0, 6-7�2266/0, 7-8�1 78810, 8-1 O�779/0 BOTCHORD 16-17=0/1420,15-16=0/2129,14-15=0/2266, 13-14=0/2129, 12-13=011420 WEBS 10-12=0/1008, 1-17=011008,8-12=-898/0, 3-17=-898/0,8-13=0/512, 3-16=0/512,7-13=474/0,4-16=474/0, 7-14=-681396, 4-15=-68/396 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6) Warning: Additional permanent and stability bracing for truss system (not part of this com�onent design) Is always required. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Ce&6634 004 Parke East Blvd, Tampa FL 33610 Date: June 8,201E WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERENCEPAGEMIJ.7473ra� 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design Is based only upon parameters shown. and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For g6neral guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality, Criteria, DSB-89 and SCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa. FL 36610 Job russ Type oty Ply Thiel Res. F L18 �Truss Floor I T1 4251795 Job eference (optional) as 0as nuss' 'G.ea, U.ZZU S May Z4 ZU1 5 Nit I eK inclustries, Inc. Fri Jun 8 07:39:27 2018 Page 1 ID:[5v—oaxuPHUsRz5LSGfsyhz93ub-?zyOBL2uNaOyygXWA9V7TxgmA8DKdwrAIxELD2z8Pg_ I-M 1-0-5 1 2-0-1 P:L1_5d op Scale: 3/8"=1' 4x6 4X4 3X4 = 1x4 11 3x3 3X3 3x3 3x4 3x3 = 6x6 1 2 3 4 5 6 7 a A in 22 21 20 19 18 17 16 15 14 13 12 11 3X3 4X6 5x5 3X6 11 3x6 11 3X6 11 3X3 3xS M18SHS FP = 4x6 3X3 11 3x3 3X4 7-4-13 r,2:,5 3 '.o.0 i 104 i Fl� '5 14-3.5 1,8-3.5 - 1rJ3 2-&0 0 40-2 9" 2., 12Z Plate Offsets (X.Y)— rl:Edge-0-1-81. fl8:0-3-0.0-0-01 LOADING (psf) SPACING- 2-0-0. CS1. DEFL. in (loc) I/deff Lid PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.67 Vert(LL) -0.27 17-18 >814 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.96 Verl(CT) -0.36 17-18 >593 240 M18SHS 244/1 90 BCLL 0.0 Rep Stress Incr YES WEI 0.64 Horz(CT) -0.01 10 n1a n/a BCDL 5.0 Code FBC2017frPI2014 Matrix-S LUMBER- BRACING- TOPCHORD 2x4 SP No.2(flat) TOP CHORD BOTCHORD 2x4 SP No.2(flat) *Except* 14-22: 2x4 SP No.1 (flat) BOTCHORD WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 22=991/Mechanical, 10=991/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-22�98910,1-2�1007/0,2-3�2586/0,3-4�3677/0,4-5=3677/0,5-6=-3772/0, 6-7=-3334/0, 7-8=-2473/0, 8-10=-1022/0 1 BOTCHORD 20-21=0/1937,19-20=0/3232,18-19=0/3677,17-18=0/3677,15-17=0/3680,13-15=013032, 12-13=0/1875 WEBS 5-18=-493/114,1-21=0/1341, 2-21=-1293/0,2-20=0/880,10-12=0/1324,'6-12=-1 193/0, 8-13=0/831, 7-13=-778/0, 7-15=0/420, 6-15=481/0, 3-20=-877/0, 3-19=0/807. 5-17=-310/438, 6-17=-21/315 9 Weight: 106 lb FT = O%F, O%E Structural wood sheathing directly applied or 5-8-7 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 18-19. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Refer to girder(s) for truss to truss connections. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-b-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. 7) CAUTION, Do not erect truss backwards. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required VValter P. Finn PE No.22839 MiTik USA, Inc. Fl. Carl 6634 004 Parke East Blvd. Tampa FL 33610 Date: June 8,2018 A&WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11711-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekS connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must vedly the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSffTPI1 QualltyZriterla, DSB.89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FL 36610 Job -----Truss Type Qty Ply Thiel Res. I J36062 FL18A rs Floor T14251796 o.zzu s iviay Z4 ZU10 mi ieK inaustnes, Inc. i­-n Jun 8 07:39:28 2018 Page I ID:15v_oaxuPHUsRz5LSGfsyhz93ub-T9WnPh3W8uWPgq6iksOM08hx?YadMN8JGb—u[Uz8Pfz 1-3-0 10-11-14 2-0-1 001 Scale: 3/8"=I' 46 4X4 3X4 = 1x4 11 3X3 3X3 3x3 3X4 3X3 = 6X6 2 3 4 5 6 7 A 1 22 21 20 19 18 1 7 16 15 14 13 12 11 3X3 4X6 5X5 3x6 11 3x6 11 3X6 11 3X3 3x3 = 3x8 M 1 8SHS FP = 4X6 3X3 11 3x4 1-60 ')-o I- =14 �-88 16.8-8 �W 2� 2.6-1 _D 2_j 4 Mo _0 2-6-0— _3 Plate Offsets (X.Y)— [1:Edqe,G-1-8l. F18-.0-3-0.0-0-01 LOADING (ps� SPACING. 2-0-0 CS1. DEFL. in (loc) Udefl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.66 Vert(LL) -0.26 17-18 >824 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.00 BC 0.96 Vert(CT) -0.36 17-18 >599 240 M18SHS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.64 Horz(CT) -o.ol 10 n/a n/a BCDL 5.0 Code FBC2017rrP]2014 Matrix-S Weight: 106 lb FT = O%F, O%E LUMBER. BRACING- TOPCHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 5-8-14 oc purlins, E30T CHORD 2x4 SP No.2(flat) *Except* except end verticals. 14-22: 2x4 SP No.1 (flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: WEBS 2x4 SP No.3(flat) 2-2-0 oc bracing: 18-19. REACTIONS. (lb/size) - 22=988/Mechanical, 10=988/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-22�986/0, 1-2�11 00310, 2-3=-2574/0, 3-4=-3649/0, 4-5�364910, 5-6=3745/0, 6-7=-3316/0, 7-8=-2462/0, 8-10=-1018/0 1 BOTCHORD 20-21=0/1930,19-20=0/3218, 18-19=0/3649, 17-18=0/3649, 15-17=0/365,7,13-15=0/3018, 12-13=0/1868 1 WEBS 5-18=-500/114, 1-21=0/1335, 2-21=-1288/0, 2-20=0/875, 10-12=0/1319. 8-12=-1188/0, 8-13=0/826, 7-13=-773/0, 7-1 5=0/415, 6-1 5=-475/0,'3-20=-873/0' 3-19=0/�99, 5-17=-307/444, 6-17=-25/313 1 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Refer to girder(s) for truss to truss connections. 5) Recommend 2x6 strong backs, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. 7) CAUTION, Do not erect truss backwards. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required Walter P. Finn PE No.22839 MiTek USA, lfi&, FL Cart 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: June 8,2018 A WARNING - VerilydesIgn parameters andREAD NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111.7473 rev. 1010312015 BEFORE USE. Design valid for use onlywith MiTekO connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability ofdesign parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 21 8 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FL 36610 Job _�FL Truss Type Q ty Ply Th iel Res. J36062 1S8 B us ]Floor T1 4251797 Job Reference (optional) --- ----- ------ o.zzu a may zq zui it mi I eK Inclustnes, Inc. Fn Jun 8 07:39:29 2018 Page 1 ID:15v—oaxuPHUsRz5LSGfsyhz93ub-xL49cl48vBeGn—hu]aYbYME6rywx5pQSUFjSHxz8Pfy 1-3-0 0-11-7 1 2-0-1 OFI-P Scale: 3/8"=I' 4X6 = 3X3 11 4X4 = 3X4 = IX4 11 3X3 = I 'A�q = 46 11 JX0 11 3X16 11 ;JX3 3x3 = 3x8 M 1 8S HS FP = 46 3X3 11 i 3x4 = 9 6-2-7 6-kJ 5 7-4-0 B-4-0 9-1-12 14-1-12 16-712 18-1 12 18-54 11M 21-1. 1-0-0 '0.9-12 2.6.0 1-6-0 o-3-6 Plate Offsets (X.Y)— [1:Edqe,0-1-81, rl8:0-3-0.0-0-01 1 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/defi Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.66 Vert(LL) -0.26 17-18 >831 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 SC 0.95 Vert(CT) -0.35 17-18 >605 240 M18SHS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.63 Horz(CT) -0.01 10 n/a n/a BCDL 5.0 Code FBC2017rrPI2014 Matrix-S Weight: 106 lb FT = O%F, O%E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 5-9-4 oc purlins, BOTCHORD 2x4 SP No.2(flat) *Except* except end verticals. 14-22: 2x4 SP No.1 (flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: WEBS 2x4 SP No.3(flat) 2-2-0 oc bracing: 18-19. REACTIONS. (lb/size) 22=984/Mechanical, 10=984/0-3-0 i FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. � TOPCHORD 1-22=982/0, 1-2=-999/0, 2-3�2562/0, 34=-3622/0, 4-5=-3622/0, 5-6=-3719/0, 6-7=-3298/0, 7-8=2451/0,8-10�1014/0 BOTCHORD 20-21 =011 922, 19-20=0/3203, 18-19=0/3622, 17-18=0/3622, 15-17=0/3634, 13-15=0/3003, 12-13=0/1860 WEBS 5-18=-508/115, 1-21 =0/1 330, 2-21 =-I 283/0, 2-20=0/870, 10-12=0/1 314, 8712=-1 184/0, 8-13=0/821, 7-13=-769/0, 7-15=0/409, 6-1 5�468/0, 3-20�870/0, 3-19=0/791, 5-17=-304/450, 6-17=-29/31 1 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Refer to girder(s) for truss to truss connections. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) CAUTION, Do not erect truss backwards. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required Walter P, Finn PE No.22639 MiTak USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa Fl. 33610 Data: June 8,2018 AwARN1NG - Verify design parameters and READ NOTES ON . TH IS AND INCLUDED MITEK REFERENCE PAGE M11.7473m, 101031201 5 BEFORE USE. Design valid for use only with MrTekO connectors. This design is based only upon parameters shown. and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrusses and truss systems. see ANSIfTP11 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute. 218 N. Lee Street. Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa. FIL 36610 Job Tru S T.russ Type ty Q�__7T Ply :Fh iel Res. J36062 FL18C Floor T1 4251798 "b Reference (optional) 8.22o s may Z4 2018 MITeK Industries, Inc. Fri Jun 8 07:39:30 2018 Page 1 ID:[5v—oaxuPHUsRz5LSGfsyhz93ub-QYdXqM5mgVm7P8G5sH3q5ZnHfMGEqG!cjvT?pNz8Pfx 1-3-0 2-0-1 5 op Scale: 3/8"=I' 4X6 4X4 3x4 1X4 11 3x3 3X3 3X3 3X4 3x3 6x6 1 2 3 4 5 6 7 8 9 10 22 21 20 19 10 11 1 16 15 14 13 12 11 3X3 4x6 5x5 3x6 11 3X6 11 W 3x3 3xB M18SHS FP = 4x6 3x3 11 3x 3x4 0-0 -2 1 0: 9 1-3-1 1 11-71 14.1-0 18-1-0 10-4 8 -61 2�� 2 2:1 _k -0, 1: _0 2-6-0 2-6-0 ;0 1-M 0�m Plate Offsets (X.Y)— rl:Edge,0-1-81, [18:0-3-0,EdaE LOADING (pso SPACING- 2-0-0 CS1. DEFIL. in (loc) I/defi Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.65 Vert(LI-) -0.25 17-18 >840 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.95 Vert(CT) -0.35 17-18 -612 240 M18SHS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.63 Horz(CT) -0.01 10 n/a n/a BCDL 5.0 Code FBC2017rrPI2014 Matrix-S Weight: 105 lb FT = O%F, O%E LUMBER- BRACING- TOPCHORD 2x4 SP NO.2(flat) TOP CHORD BOTCHORD 2x4 SP No.2(flat) *Except* 14-22: 2x4 SP No.1 (flat) BOTCHORD WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 22=981 /Mechanical, 10=981/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-22=-979/0,1-2=-996/0, 2-3=-2551/0, 3-4=-3594/0, 4-5=-359410, 5-6=-3692/0, 6-7=-3280/0, 7-8=-2440/0, 8-10=-1010/0 1 BOTCHORD 20-21=011914,19-20=0/3189,18-19=0/3594,17-18=0/3594,15-17=0/3611,13-15=012989, 12-13=0/1853 WEBS 5-18=-515/116,1-21=0/1325,2-21=-1278/0,2-20=0/864,10-12=011309,8-12=-Il79/0, 8-13=0/816, 7-13=-764/0, 7-15=0/404,6-15=-461/0, 3-20=-866/0,3-19=01784, 5-17=-301/457, 6-17=-33/309 Structural wood sheathing directly applied or 5-9-11 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. Except: 2-2-0 oc bracing: 18-19. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Refer to girder(s) for truss to truss connections. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0,131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) CAUTION, Do not erect truss backwards. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required ffilter P. Finn PE No.22839 MiTek USA Inc. Fl. C48634 6904 Parke`�.,t 8W. Irtirpa FL 33610 Data: June 8,2018 ,&WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGEMII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekQD connectors. Th Is design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIrTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandriia, VA 22314. Tampa, FL 36610 Job Tru s russ T Truss Type Qty Ply Thiel Res. �36062 FL18D T1 4251799 Job Reference (optional) 1-3-0 4x6 4x4 1 2 o.zzu a ivtayz4 zu-to NiiieK maustries, Inc. 1--nJun 8 07:39:31 2018 Page 1 ID:]Sv—oaxuPHUsRzSLSGfsyhzg3ub-ukBvli5ORpL�_OlrHP?a3enJSVmbXZjjyZCYLpz8Pfw 2-0-1 OFL-f Scale = 1:31.7 3x4 1x4 11 3x3 3X3 3x3 3x4 3x3 = 6x6 3 4 5 6 7 8 In ROME/& "VIA 9 5x5 3X6 11 3x6 11 3)W 3X3 4x6 3x3 3x8 M1 SS HS FP 4X6 3X3 11 3X6 III 3X4 'o B-1-10 6- -1 1 LI-In! 2:04 1 j�'64 -0-4 16-6.4 Z�o� 11 - 2 1-16 2�2 2�1 1 o 01 6 2-6-0 _�Iate Offsets (X,Y)— [J:Eqge 0-- __0-1-81. T18:0-3-0. LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) Ildefi L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00' TC 0.64 Vert(LL) -0.25 17-18 >849 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.95 Vert(CT) -0.35 17-18 >61 8 240 M18SHS 244/190 BCLL 0.0 Rep Stress Incr YES WEI 0.63 Horz(CT) -0.01 10 n/a n/a BCDL 5.0 Code FBC2017rrP]2014 Matrix-S Weight: 105 lb FT = O%F, O%E LUMBER- NOG C'N TOPCHORD 2x4 SP No.2(flat) TBORA Structural - T P CH Structural wood sheathing dir TOAC' O;D od sheathing directly applied or 5-10-1 oc purlins, BOTCHORD 2x4 SP No.2(flat) *Except* rhC.Is except end vefficals. 14-22: 2x4 SP No.1 (flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: WEBS 2x4 SP No.3(flat) 2-2-0 oc bracing: 18-19. REACTIONS. (lb/size) 22=977/Mechanical, 10=977/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-22�975/0, 1-2�991/0, 2-3=-2539/0, 3-4�3567/0, 4-5=-3567/0, 5-6=-3665/0, 6-7=-3261/0, 7-8=-242810, 8-1 0=-1 006/0 1 BOTCHORD 20-21 =0/1907,19-20=0/3175,18-19=0/3567,17-18=0/3567,15-17=0/3588,113-15=0/2974, 12-13=0/1845 WEBS 4-19=-250/0, 5-1 8=-524/117, 1-21 =0/1 319, 2-21 =-1 273/0, 2-20=0/859, 10-12=0/1 304, 8-12=-1 174/0, 8-13=0/81 1, 7-13=-759/0, 7-15=0/399, 6-1 5�454/0, 3-20=-863/0, 3-19=0/777, 5-17=-298/464, 6-17�38/307 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Refer to girder(s) for truss to truss connections. 5) Recommend 2x6 strong backs, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) CAUTION, Do not erect truss backwards. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Walter P. Finn PE No.22839 IOTA USA, Inc. FL Carl 13634 604 Parke East Blvd. Tampa Fl. 33610 Date: June 8,20fl WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTeklD connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall Vat building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property clarnage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa, FL 36610 a Job russ Type Qty Ply Thiel Res. T �Truss T1 4251800 Lb J36062 FL18E Floor 1 1 Reference (optional) 1-3-0 4x6 4X4 1 2 22 21 3X3 46 mzzu s iviay,44;dUlti iviiieli inaustries, Inc. Fri Jun 5 07:39:32 2018 Page 1 ID:15v_oaxuPHUsRz5LSGfsyhzg3ub-MwIHE26lC60qeSPTzi5lA—seL9xr[AHvBDy6uFz8Pfv 2-0-1 opq Scale 1:31.5 3X4 1X4 3x3 3x3 3x3 3X4 3x3 6x6 3 4 5 6 7 8 9 10 C5 20 19 is 1 71 16 5X5 3X6 3.6 11 3x3 3X6 11 7-2-12 15 14 13 12 11 3x3 = 3xB M 1 8SHS FP = 4x6 3X3 3X4 111's LOADING (psf) SPACING- 2-0;0 CS DEFL. in (loc) Uclefi Ud PLATES GRIP TCLL 40.0 Plate Grip DOL I . 0. TC'. 0.64 Vert(LL) -0.25 17-18 >858 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.94 Vert(CT) -0.34 17-18 >624 240 M18SHS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.63 Horz(CT) -0.01 10 n1a n/a BCDL 5.0 Code FBC2017/TPI2014 Matrix-S Weight: 105 111 FT = O%F, O%E LUMBER- BRACING- TOPCHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 5-10-10 oc purlins, BOTCHORD 2x4 SP No.2(flat) *Except* except end verticals. 14-22: 2x4 SP No.1 (flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: WEBS 2x4 SP No.3(flat) 2-2-0 oc bracing: 18-19. REACTIONS. (lb/size) 22=974/Mechanical, 10=974/0-3-0 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-22=-972/0, 1-2=-987/0, 2-3=-2528/0, 3-4=-3539/0, 4-5=-3539/0, 5-6=-3639/0, 6-7�324310, 7-8�2417/0, 8-10�1002/0 1 BOTCHORD 20-21 =0/1 899, 19-20=0/3162, 18-19=0/3539, 17-18=0/3539, 15-17=0/356 5, 13-15=0/2960, 12-13=0/1838 WEBS 4-19=-254/015-18=-533/118,1-21=0/1314,2-21=-1268/0,2-20=0/854, IOL12=0/1298, 8-12=-1 169/0, 8-13=01806, 7-13=-755/0, 7-15=0/394, 6-1 5=-448/0, 3-202860/0, 3-19=0/771, 5-17�296/472, 6-17=-42/304 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. * 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Refer to girder(s) for truss to truss connections. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) CAUTION, Do not erect truss backwards. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required Walter P. Finn PE No.22839 MiTek USA, Inc, FL Cod 6634 6904 Parke East Blvd. Tampa FL 33610 Date: June 8,2018 ,&WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473rev� 1610312015 BEFORE USE. Design valid for use only with Mrreke connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use. the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication. storage, delivery, erection and bracing oftrusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 lob S Truss Type Qty Ply Thiel Re . S J36062 7FLUIS9 �Floor 1 T1 4251801 Job Reference (optional) 1-3-0 4x6 4x4 2 ts.zzu S mayz4 Zulu MileX Industries, Inc. Fri Jun 8 07:39:33 2018 Page I ID:15v oaxuPHUsRz5LSGfsyhz93ub-q7JgSO7fzQ8hGb f/ cXiCPoaZGglcl2PthfQiz8pfu Q 1-0-12 2-0-1 OFL-P Scale: 3/8"=l' 3X4 = IX4 11 3x3 3X3 3X3 3X4 3X3 = 6x6 3 4 5 6 7 a Q in 3X3 11 4x6 5x5 3X6 11 3X6 11 3X6 11 3x3 = — 3x3 = 3x8 M 1 8S HS FP 4x6 3x3 11 3X4 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Ildefl Lid TCLL 40.0 Plate Grip DOL 1.00 TC 0.67 Vert(LL) -0.27 17-18 >807 360 TCDL 10.0 Lumber DOL 1.00 BC 0.97 Vert(CT) -0.37 17-18 >588 240 BCLL 0.0 Rep Stress Incr YES WB 0.64 Horz(CT) -0.01 10 n/a n/a BCDL 5.0 Code FBC2017/TPI2014 Matrix-S LUMBER- BRACING- TOPCHORD 2x4 SP No.2(flat) TOP CHORD BOTCHORD 2x4 SP No.2(flat) *Except* 14-22: 2x4 S P No. 1 (flat) BOTCHORD WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 22=995/Mechaniral, 10=995/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-22=-993/011-2�1 011/0, 2-3�2597/0, 3-4�3705/0, 4-5=-3705/0, 5-6=-379910, 6-7=-335210, 7-8=-2484/0,8-10=-1026/0 BOTCHORD 20-21 =0/1 945,19-20=0/3246, 18-19=013705, 17-18=0/3705, 15-17=0/3703, 13-15=0/3047, 12-13=0/1883 WEBS 5-18�487/113, 1-21 =0/1 346, 2-21 �11 298/0, 2-20=0/885, 10-12=0/1 330, 8-12=-1 198/0, 8-13=01836, 7-13�783/0, 7-15=0/425, 6-15=-488/0, 3-20=-880/0, 3-19=0/816, 5-17=-313/432, 6-17=-1 6/317 PLATES GRIP MT20 244/190 M18SHS 244/190 Weight: 107 lb FT = O%F, O%E Structural wood sheathing directly applied or 5-8-1 oc puffins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 18-19. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Refer to girder(s) for truss to truss connections. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 11 X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) CAUTION, Do not erect truss backwards. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: June 8,2018 WARNING -Verify design parameters and READ NOTES ONTHIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev, 1010312015 BEFORE USE. Design valid for use only with MiTeks connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek' fabrication, storage. delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 Quality CrIterla, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. . Tampa, FL 36610 I Job S Qty Ply Thiel Re 5 J36062 TF'Luls9A �F . [oar 1 1 T1 4251802 � ­­ I - _. Job Reference (optional) 0-1-8 H 1 0-11-5 1-4-9 1-3-0 0.44U b Mdy 4q Z.0 10 ivii i eK inausines, Inc. t-n Jun It$ U(:39:34 2018 Page 1 1 D:]5v_oaxuPHUsRz5LSGfsyhz93ub-lJt2fk8HkkGYtlZs577mFPxzszcLmODBeXRDy8z8Pft 0 8 Acale: 318"=l' 46 46 3x8 1X4 11 3X6 1X4 11 3X4 1x4 11 3x3 1X41 11 3X3 1X4 11 3X4 1X4 11 3x6 1X4 11 1X4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 t3 - - - 29 at A I 1 26 25 24 23 22 21 20 19 18 17 3x8 48 3X8 3X4 5X6 11 5X6 11 5X5 3xS M18SHS FP = 4x8 3x3 3X4 3X8 1 9-0-14 19-0-14 Plate Offsets (X,Y)— fl:Edae.0-1-81. 1`15:0-1 -8. Edge], [21:0-2-8,Edgel, [28:0-1-8.0-1-81, [29:0-1-8.0-0-81 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/def] L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.70 Vert(LL) -0.51 22 >445 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 1.00 Verl(CT) -0.70 22 >324 240 M18SHS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.85 Horz(CT) 0.08 16 n1a n/a BCDL 5.0 Code FBC2017rrPI2014 Matrix-S Weight: 111 lb FT = O%F, O%E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 3-8-15 oc puffins, BOTCHORD 2x4 SP No.1(flat) *Except* except end verticals. 20-24: 2x4 SP No.2(flat) WEBS � A 0. 11 1 . I BOTCHORD Rigid ceiling directly applied or 1-4-12 oc bracing. x a. k a, REACTIONS. (lb/size) 16=1025/0-3-8,27=1001/1-0-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-27=-1049/0,15-16=-1024/0,1-2=�-1587/0,2-3=-1587/0,3-4=-3803/0,4-5=-3803/0, 5-6=-5312/0, 6-7�531210, 7-8=-589810, 8-9�5898/0, 9-1 0=-5268/0, 10-1 =-5268/0, 11-12=-3718/0,12-13=-3718/0,13-14=-1584/0, 14-15=-1584/0 BOTCHORD 26-27=0/357, 25-26=0/2860, 23-25=014649, 22-23=015745, 21-22=0/5723, 18-21 =0/4583, 17-18=0/2751 WEBS 15-17=0/1 791, 13-17�1 402/0, 13-18=0/1 163, 11-18=-1 039/0, 5-25�1 016/0, 3-25=0/1 134, 3-26=-1 488/0, 1-26=0/1 557, 5-23=0/780, 7-23=-509/0, 9-21—_'_535/0, 11-21 =0/805 NOTES- 1) All plates are MT20 plates unless otherwise indicated. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Required 2x6 strong backs, on edge, spaced at 10-0-0 oc and fastened to each truss with13-10d (0.131" X 3") nails. Strongbacksto be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. 5) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. VValter P. Fifin PE No.22839 MiTak USA, Inc. FL Cerlt8634 6904 Parke East Blvd. Tampa FL 3*0 Date: June 8,201E ,&WARNING - V-dfydsig. parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design Is based only upon parameters shown, and is for an indiAdual building component, not Bet a truss system. Before use, the building designer must verfy the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chard members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTP11 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa, FL 36610 Job Truss uss Truss Type Qty Thiel Res. J36062 FL21 ]!F�r .. 1 �Ply 1 Tl 4251803 _iJ ob Reference (optional) 0-3-6 H 1 1-3-0 ill U."" a IAay z4 zultj mi I eK industries, inc..Fn Jun 8 07:39:35 2018 Pagel ID:15v—oaxuPHUsRz5LSGfsyhz93ub-mVRQt49vVl OPVv82ere?odU8LNOQVVVfLtBAmUaz8F'fs i 1-0-14 1 2-0-1 1 1-1-13 6x6 � 3x3 44 3x3 3X3 1 3X3 lx4 11 3X4 4X4 3x3 � 6x6 1 2 3 4 5 1 6 7 8 9 in 11 9-7-12, Ea�le— 1:33.7 4-3& L-9& 9-3.6 10-15-12 0.1 91 oi3l I � . 2.,.0 12-7-5 1 5-13 12-5-13 15 O�2 19TQ.�2 — is 19-7-14 " -,7.111 _0 2-6-0 1- _0_0 0 2-6 1-0-0 1 _ 3 2-6-0 T 1 Plate Offsets (X,Y)— It 7:0-3-0, Edge], [20:0.1-12.Edgel 0-0-1 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00. TC 0.65 Vert(LL) -0.28 18-19 >792 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.76 1 Verl(CT) -0.38 18-19 >576 240 BCLL 0.0 Rep Stress Incr YES WB 0.65 Horz(CT) -0.07 11 n/a n/a BCDL 5.0 Code FBC2017/TPI2014 Matrix-S Weight: 116 lb FT = O%F, O%E LUMBER- BRACING- TOPCHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 5-2-0 oc purlins, BOTCHORD 2x4 S P No. I (flat) *Except* except end verticals. 12-16: 2x4 SP No.2(flat) E30T CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 1=1016/0-2-13,11=1016/0-7-8 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-3=-1052/0, 34=-2550/0, 4-5=3667/0; 5-6=4035/0, 6-7�3865/0, 7-8=-3865/0, 8-9=-260610, 9-11 =-1 050/0 BOTCHORD 21-22=0/1 929, 20-21 =0/3224, 19-20=0/3996, 18-19=0/3865, 17-18=0/3865�. 15-17=0/3326, 13-15=011 945 1 WEBS 6-18=-518/51, 1-22=0/1 364, 3-22�1 22710, 3-21 =0/863, 4-21 =-936/0, 4-20j70/602' 11-13=011361, 9-13=-1251/0,5-19=-75/265, 6-19=-272/497,8-17=0/894,s-115=-978/0, 5-20=-447/0, 9-15=0/897 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1. 4) Recommend 2x6 strong backs, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 1 5) Gap between inside of top chord bearing and first diago'nal or ver�cal web shall not exceed 0.500in. 6) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. VValter P. Finn PE No.22839 MiTek USA, Inc. FL Cert 6634 604 Parke East Blvd. Tampa FL 33610 Date: June 8,2018 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with Mrrek(ll) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verily the applicability ofdesign parameters and property incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' falnication, storage. delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Inslitute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job S Truss Type Qly Ply Thiel Res. J36062 �FL2S2 �Floor T1 4251804 —Job Re rence (optional) 0-3-8 H i 1-3-0 6X6 = 3x3 4X6 1 2 3 4 I -�l G.ZZU 5 May 44 ZU Id No I eK inausines, Inc. i--n Jun 8 07:39:37 2018 Page 1 ID:15v—oaxuPHUsRz5LSGfsyhz93ub-!uYAlnIA91fe7kDlRmFhTt2ZP7AfnzMEeKVftZTz8Pfq 2-0-1 7&A- 0?4 Scale = 1:38.5 i 3X3 = 3X4 3X3 3X3 3X3 M FP = 3x4 4x4 3x3 = 6x6 5 6 7 8 9 10 11 1 � I � I I 27 26 25 24 23 22 21 20 19 18 17 16 15 3X3 11 5X6 4x4l = I 3x8N118SHSFP 3x6 3x6 11 5x8 4x4 4X6 = 3X3 11 5X8 = 3X6 11 3X6 11 6 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Well Lid PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.96 Vert(LL) -0.43 21 >600 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.89 Vert(CT) -0.59 21 >437 240 M18SHS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.90 Horz(CT) -0.09 14 n/a n/a BCDL 5.0 Code FBC2017rrPI2014 Matrix-S Weight: 128 lb FT = O%F, O%E LUMBER- BRACING- TOPCHORD 2x4 SP No.2(flat) *Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, 1-10: 2x4 SP 285OF 1.8E(flat) except end verticals. BOTCHORD 2x4 SP No. 1 (flat) *Except* BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 18-24: 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 1=1185/0-2-15,14=1189/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1452/0, 4-5=-3384/0. 5-6=-4785/0, 6-7=-5442/0, 7-8=-5541/0, 8-9�538 1/0, 9-11=-4622/0, 11-12=-3103/0,12-14=-1252/0 BOTCHORD 25-26=0/2679, 24-25=0/4170, 22-24=0/5248, 21-22=0/5541, 20-21=015541,119-20=0/5541, 18-19=0/5120,17-18=0/3980,16-17=0/2301 WEBS 7-21=-406/370,8-20=-360/501, 2-26=011890. 4-26�1707/0,4-25=0/980,5-25=-1091/0, 5-24=0/836,14-16=0/1624,12-16=-1466/0,12-17=0/1115,11-17=-1217/0,11-18=0/874, 6-22=0/474, 6-24�628/0. 7-22�636/298, B-19=-770/227, 9-19=0/544, 9-18=-675/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. VValter F. Finn PE No.22839 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: June 8,201 'A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGEM11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekaD connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa. FL 36610 'u Truss Type Qty Ply Thiel Res. T14251805 Job F rL2s2sA 1 J36062 Floor Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, 8.220 a May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:38 2018 Page I ID:15v—oaxuPHUsRz5LSGfsyhz93ub-B46ZV6Bnoyrr�_MNtdKzCiQF6awa?5ipXnZ9PQ5vz8Pfp 0-3-8 1-3-0 R:L911 91-1-1 ?:L-A Scale = 1:38.4 6x6 3x3 4X6 1 2 3 4 MRS: 3X4 3x3 34 3x3 W = 3x6 FP = 3x4 44 3x3 =6x6 5 6 7 8 9 10 11 12 13 14 27 26 25 24 23 22 21 3x3 11 5X6 4X4 3x8 M18SHS FP = 3X6 5X8 = 3X6 11 20 19 18 17 16 15 3X6 11 5x8 4X4 46 = 3X3 11 3X6 11 2 9 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.95 Vert(LL) -0.43 21 >605 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.00 BC 0.89 Vert(CT) -0.59 21 >440 240 M18SHS 244/190 BCLL 0.0 Rep Stress Incr YES we 0.90 Horz(CT) -0.09 14 n/a n/a BCDL 5.0 Code FBC2017rrPI2014 Matrix-S Weight: 127 lb FT = O%F, O%E LUMBER- BRACING- TOPCHORD 2x4 SP No.2(flat) *Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, 1-10: 2x4 SP 285OF 1.8E(flat) except end verticals. BOTCHORD 2x4 SP No.l(flat) *Except* BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 18-24: 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) REACTIONS. (lb/sIze) 1=1182/0-2-15, 14=1186/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-4�1447/0, 4-5=-3371/0, 5-6=-4764/0, 6-7=-5415/0, 7-8�5508/0, 8-9=-535610, 9-11=-4603/0,11-12=-3092/0,12-14=-1248/0 BOTCHORD 25-26=0/2670, 24-25=0/4154, 22-24=0/5223, 21-22=0/5508, 20-21=0/5508, 19-20=0/5508, 18-19=0/5096,17-18=0/3965,16-17=012294 WEBS 7-21 =-414/377, 8-20=-368/510, 2-26=0/1 884, 4-26=-1 701/0, 4-25=0/975, 5-25�1 08610, 5-24=0/830,14-16=0/1619,12-16=-1461/0,12-17=0/1110, 11-17=-1212/0,11-18=0/868, 6-24=-622/0, 6-22=0/474. 7-22=-636/307, 8-19�772/235, 9-19=0/543, 9-18=-669/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1. 5) Recommend 2x6strongbacks, an edge, spaced at 10-0-0 oc and fastened to each truss'with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cert 66 ' 34 004 Parke East Blvd. Tampa Fl. 33610 Date: June 8,2018 'A WARNING - Verify design parameters and READ NOTES ON 3'HIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 re� 1010312015 BEFORE USE. Design valid for use only with WOO connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for MiTek* stability and to prevent collapse with possible personal injury and property damage. For'general guidance regarding the fabrication. storage, delivery, erection and bracing oftrusses and truss systems, see ANSIITPI1 Quality Criteria, DSB.89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, AJaxandda, VA 22314. 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Qty Ply Thiel Res. J36062 FL22B Floor 1 1 TI 4251806 Inn Reference (optional) 0-3-8 H i 1-3-0 6x6 = 3x3 1 2 3 P1 46 4 O.ZZU 5 IVIUY Iff ZU 10 IVII I eK inausines, Inc. i-n jun u ut:;3v:3u zula Page 1 ID:15v_oaxuPHUsRz5LSGfsyhzg3ub-fHgxjRCQZGur—WSptgjxyTelj_LPRHqxopLdLz8Pfo 2-D-1 0�4 Scale = 1:38.3 3x4 3x3 3x3 3x3 3x3 = 3x6 FP = 3x4 4x4 3x3 = 6x6 5 6 7 8 9 10 11 17 11% 1A 27 26 25 24 23 22 21 20 19 18 17 16 15 3X3 11 5X6 4X4 3xS M18SHS FP 3x6 11 3X6 11 5xB 4X4 4X6 = 3X3 11 5x8 = 3X6 11 3X6 11 0 1 V9 4-3-8 9:62� -o- _0� 1�,� 8 2c)-l-8 71-7-R91.1`1-0 0�31 0 5_ 0 0_0 0.0 .0 2-6-0 1-6-0 013j8 Plate Offsets (X.Y)— [20:0-3-0.0-0-01 1 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.95 Vert(LL) -0.42 21 >61 0 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.88 1 Vert(CT) -0.58 21 >444 240 M18SHS 244/190 BCL� 0.0 Rep Stress Incr YES WB 0.89 Horz(CT) -0.09 14 n/a n/a BCDL 5.0 Code FBC20171TPI2014 Matrix-S Weight: 127 lb FT = O%F, O%E LUMBER- BRACING- TOPCHORD 2x4 SP NO.2(fiat) *Except* TOP CHORD 1-10: 2x4 SO 285OF 1.8E(flat) BOTCHORD 2x4 SP No. I (flat) *Except* BOTCHORD 18-24: 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 1=1178/0-2-15,14=118210-3-0 FORCES. (lb) -Max. Comp.lMax. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-4=-1442/0, 4-5=-3359/0, 5-6�4743/0,6-7=5389/0, 7-8=-5475/0,8-9=-5331/0, 9-11=-4583/0,11-12=-3081/0,12-14=-1244/0 I BOTCHORD 25-26=0/2661, 24-25=0/4138, 22-24=0/5198, 21-22=0/5475, 20-21 =0/5475, 19-20=0/5475, 18-19=0/5073, 17-18=0/3949, 16-17=0?2286 1 WEBS 7-21 =-424/386, 8-20=-376/518, 2-26=0/1 877, 4-26�1 696/0, 4-25=01971, 5-25�1 081 /0' 5-24=0/824, 14-16=0/1 613, 12-16�1 456/0, 12-17=0/1 105, 111-17=-1 206/0,111-18=0/862, 6-24=-617/0, 6-22=0/474, 7-22=-638/316, 8-19=-775/245, 9-19=01543, 9-18=-664/0 Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1. 5) Recommend 2x6 strong backs, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails, Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 8634 6904 Parke East Blvd, Tampa Fl. 33610 Date: June 8,2018 AwARiviNo. Verifyd..Ignp.rarnefens and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGEM11.7473rv. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly ln�orporate this design Into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for'stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing of trusses and truss systems. see ANSIITP11 Quality Criteria, DSB.89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa, FL 36610 Job Type Thiel Res. 36062 1 FL22C East Coast Truss, Ft. Pierce, FL - 34946, 0-3-8 H i 1-3-0 6x6 = 3x3 46 1 2 3 4 2WX 11 01 IN 1 1 �Job Reference (optional) T1 4251807 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:40 2018 Page I ID:15v_oaxuPHUsRz5LSGfsyhzg3ub-7TEJwnC2JaOicglOROEAVgBwWOhiAk74OTuXAoz8Pfn 00:14 1 2-0-1 Of4 Scale 1:38.2 3X4 3x3 3x3 3x3 3x3 3x6 FP 3x4 44 3x3 6x6 5 6 7 8 9 10 11 12 13 14 27 26 25 24 23 22 21 20 19 18 17 16 15 3X3 5X6 4x4 3x8 M18SHS FP 3x6 11 3X6 11 5x8 4X4 46 = 3x3 5x8 3x6 3x6 11 10-11-11 12.6-12 1:63-68 1-8 1-.12t.'.1 15,0-12 1Z1t512 2,0-0:612 11 12 Ll 1 4 _E_6 i 2_ '�l F5 !:N 0 Of! 11-.6-1 1 - Plate Offsets (X.Y)— [20:0-3-0 0-0-01 1 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud TCLL 40.0 Plate Grip DOL 1.00 TC 0.95 Vert(LL) -0.42 21 >614 360 TCDL 10.0 Lumber DOL 1.00' BC 0.88 Vert(CT) -0.58 21 >447 240 BCLL 0.0 Rep Stress Incr YES WB 0.89 Horz(CT) -0.09 14 n/a n/a BCDL 5.0 Code FBC2017rrPI2014 Matrix-S LUMBER- BRACING- TOPCHORD 2x4 SP No.2(flat) *Except* TOPCHORD 1-10: 2x4 SP 285OF 1.8E(flat) BOTCHORD 2x4 S P No. 1 (flat) *Except* BOTCHORD 18-24: 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) REACTIONS. (IbIsize) 1=1 17510-2-15,14=1 179/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1 437/0, 4-5=-3347/0, 5-6=-472310, 6-7=-5362/0, 7-8=-5442/0, 8-9=-530510, 9-11=-456410,11-12=-307010,12-14=-1240/0 BOTCHORD 25-26=0/2652, 24-25=0/4122, 22-24=0/5173, 21-22=0/5442, 20-21=0/5442,19-20=0/5442, 18-19=0/5050,17-18=0/3934,16-17=0/2279 WEBS 7-21 =-434/395, 8-20=-385/528, 2-26=011 871, 4-26�1 690/0, 4-25=0/966, 5-25=-1 076/0, 5-24=01818,14-16=0/1608,12-16=-1451/0,12-17=0/1100, 11-17=-1201/0,111-18=0/856, 6-24=-611/0, 6-22=-0/475, 7-22=-640/327, B-19=-779/255, 9-19=0/543, 9-18�659/0 PLATES GRIP MT20 244/190 M18SHS 244/190 Weight: 127 lb FT = O%F. O%E Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0.131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Walter P. Finn PE No.22839 MJT,e.k USA, Inc. FL Cart 6634 690,4 Parke East Blvd. Tampa FL 33610 Data: June 8,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010212015 BEFORE USE. Design valid for use only with Mire k0 connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing is always required for to MiTek' stability and prevent collapse with possible personal Injury and property damage. For go�eral guidance regarding the fabrication. storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Qty Thiel Res. J36062 FL22D Floor I �Ply T14251808 Job Reference (optional) 0-3-8 H ! 1-3-0 rl-1-010011., 4X6 4 27 26 25 3X3 11 5X6 4X4 o.zzv s iviay.&,; zwo PAiieK inaUSInes, Inc. Fn Jun 8 07:39:4Z 2018 Page 1 ID:[5v—OaxuPHUsRz5LSGfsyhzg3ub-3rM3LTEIrBHQr�_AOZpGea5GG38NFeefNUnNeEgz8Pfl 3X4 3x3 3X3 3X3 3x3 = 3x6 FP = 3x4 5 6 7 8 9 10 11 -24 23 22 21 3X8 M18SHS FP M 11 5x8 = 3x6 11 20 19 18 17 3 1 — X6 1 5X8 — 4x4 34 12-6-0 .5 111.11.5 . . LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud TCLL 40.0 Plate Grip DOL 1.00 TC 0.94 Vert(LL) -0.41 21 >619 360 TCDL 10.0 Lumber DOL 1.00 BC 0.87 Vert(CT) -0.57 21 >450 240 BCLL 0.0 Rep Stress Incr YES WE 0.89, Horz(CT) -0.09 14 n/a n/a BCDL 5.0 Code FBC2017rrPI2014 Matrix-S LUMBER- BRACING- TOPCHORD 2x4 SP No.2(flat) *Except* TOP CHORD 1-10: 2x4 SP 2850F 1.8E(flat) BOTCHORD 2x4 SP No.1(fiat) *Except* BOTCHORD 18-24: 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 1=1171/0-2-15,14=117610-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-143310, 4-5=-3334/0, 5-6�4702/0, 6-7�5335/0, 7-8�5409/0, 8-9=-5280/0, 9-1 1=-4544/0,11-12=-3059/0,12-14=-1236/0 I BOTCHORD 25-26=0/2643, 24-25=0/4105, 22-24=0/5149. 21-22=015409, 20-21=015409� 19-20=0/5409. 18-19=0/5027,17-18=0/3919,16-17=0/2271 WEBS 7-21 =-445/406, 8-20=-395/538, 2-26=0/1 865, 4-26�1 68410, 4-25=01961, 5-25=-1 070/0, 5-24=0/811, 14-16=0/1603,12-16�1446/0,12-17=0/109!5,11-17=-1195/0,,�i-i8=0/850, 1 6-24=-606/0, 6-22=-4/475, 7-22=-644/338, 8-19=-784/265, 9-19=01544, 9-18=-654/0 1 IT Scale = 1:38.1 4X4 3x3 = Sx6 12 13 14 9 16 15 4x6 = 3X3 PLATES GRIP MT20 244/190 M18SHS 244/190 Weight: 126 lb FT = O%F, O%E Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verlicals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 Plates ulinless otherwise indicated.' 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. VValter P. Finn PE No.22839 MiTek USA, Inc. FL Cod 6634 6904 Farke East Blvd. Tampa FL 33610 Date: June 8,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek4l) connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use. the building designer must verify the applicability of design parameters and properly In6orporate this design Into the overall buildIng design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For gen�ral guidance regarding the MiTek' fabrication. storage, delivery, erection and bracing oftrusses and truss systems, see ANSI1TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Cee Street, Suite 312, AJexandda, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Thiel Res. t T14251809 � J36062 FL22E Floor 1 Job Reference (ootional) .... ...... rt. riv—, 0-3-8 H 1 1-3-0 6x6 = 3x3 4X6 1 2 3 4 25 It IMS0.0 11% +0 Q14 "" N U.ZZU S May Z4 ZU18 MiTek Industries, Inc. Fri Jun 8 07:39:43 2018 Page 1 ID:15v—oaxuPHUSRzSLSGfsyhz93ub-X2wSYpFwcVPHT8la6Wot7JpRrbjZN5yWjR6Bn7z8Pfk 0"' 1 2-0-1 *V 011-f Scale = 1:38.0 3X4 3x3 3x3 5 6 7 4X4 3x3 = 3x6 FP = 3x4 4x4 3x3 = 6x6 8 9 10 11 12 13 14 27 26 25 24 23 22 21 1 20 19 is 17 16 15 3X3 11 5X6 4X4 3x8 M1 8SHS FP 3X6 11 3X6 11 5x8 4X4 46 = 3x3 11 5X8 3X6 3X6 11 n i-A 1_­ �10-10-14 ..12-5.4 0234 1 2-6-0 1 2.6-0 2-6-0 0-7- 6 1 1-0.0 1 , , 1-0-0 (5.&5' ' 2-6.0 t — to Plate Offsets (X,Y)— r8:0-1-8,EdqeI. [20:0-3-0.0-0-01 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.94 Vert(LL) -0.41 21 >624 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.87 Vert(CT) -0.56 21 >454 240 M18SHS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.88 Horz(CT) -0.08 14 n/a n1a BCDL 5.0 Code FBC2017rrP[2014 Matrix-S Weight: 126 lb FT = O%F, O%E LUMBER- BRACING- TOPCHORD 2x4 SP No.2(flat) *Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, 1-10: 2x4 SP 285OF 1.8E(flat) except end verticals. BOTCHORD 2x4 SP No. 1 (flat) *Except* BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 18-24: 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) 1=1 16810-2-15,14=1172/0-3-0 REACTIONS. (lb/size) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-4=-1428/0, 4-5=-3322/0, 6-6=-4681/0, 6-7=-5308/0, 7-8=-5376/0, 8-9=-52.55/0, 9-1 1=-4525/0,11-12=-3048/0,12-14=-1232/0 BOTCHORD 25-26=0/2634, 24-25=0/4089, 22-24=0/5124, 21-22=0/5376, 20-21=0/5376� 19-20=0/5376, 18-19=0/5004,17-18=0/3904,16-17=0/2264 11 WEBS 7-21 =-458/415, 8-20=-406/549, 2-26=0/1 858, 4-26�1 678/0, 4-25=0/956, 5-25=-1 065/0, 5-24=0/805,14-16=0/1598,12-16�1442/0,12-17=0/1090,11-17=-1189/0, 11-18=0/844, 6-24=-60010, 6-22=-8/476, 7-22�648/351, 8-19=-790/277, 9-19=0/544, 9-1 8=-649/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Walter P. Finn PE No.22839 MiTek USA, Inc. F1 Carl 6634 604 Parke East Blvd. Tampa Fl. 336 . 10 Data: J u ne 8,201 ,&WARNING. Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekQD connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Sol' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication. storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB.89 and Boat Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa, FL 36610 Job 'Lu2ss' Truss Type Qty Ply Thiel Res. J36062 TF �!`Joor TI Lb Reference (optional) ?j.zzu s may z4 zuit5 mi I eK inoustnes, Inc. Frijun 807:39:442018 Pagel ID:]5v_oaxuPHUsRz5LSGfsyhz93ub-?EUqm9GYNoX74IKngEJ6fWMe3?2K6aOgx5skJZz8PfI 0-3-8 1-3-0 0�f Scale = 1:37.9 5X6 3X3 4x4 3X4 3x3 3x3 1 2 3 4 5 6 26 25 24 23 22 21 20 lx4 46 4X4 3X8 M18SHS FP 3X6 5X8 3X6 3x4 4X4 3X3 3X6 FP 7 8 9 10 19 18 17 16 3x6 11 5x8 4x4 3x6 12-4.7 4x4 3x3 = 6x6 11 12 13 15 14 4x6 = 3x3 11 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.78 Vert(LL) -0.40 19-20 >621 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.83 Vert(CT) -0.56 19-20 >451 240 Ml8SHS 244/190 BCLL 0.0 Rep Stress Incr YES WE 0.74 Horz(CT) -0.10 13 n/a n/a BCDL 5.0 Code FBC2017ITP12014 Matrix-S Weight: 125 lb FT = O%F, O%E LUMBER- BRACING- TOPCHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 3-10-0 oc purlins, BOTCHORD 2x4 S P No. 1 (flat) *Except* except end verticals. 17-23: 2x4 SP No.2(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 cc bracing. WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 1=1149/0-3-0,13=1149/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 260 (lb) or less except when shown. TOPCHORD 1-3=-1 155/0, 34�2936/0, 4-5=-437410, 5-6=-5050/0, 6-7=-5166/0, 7-8=-5070/0, 8-10=-439810,10-11=-2975/0,11-13=-1205/0 I BOTCHORD 24-25=0/2168, 23-24=0/3774, 21-23=0/4832. 20-21 =0/5166, 19-20=0/5166. 18-19=0/5166, 17-18=0/4848, 16-17=0/3805, 15-16=012214 WEBS 6-20=-3941421, 7-19=-453/547,1-25=011527,3-25=-1416/0,3-24=0/1068, 4-24�1162/0' 4-23=0/817.13-15=0/1563,11-15=-1410/0,11-16=0/10li8,10-16=-1153/0..'10-17=0/806, 5-23=-621/0, 5-21=0/484, 6-21�672/262,7-18�7651320,8-18=0/508, 8-17�611/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. 6) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Walter P. Fin n PE No.22839 MiTek USA, lAc. F1 Carl 66 ' 34 $904 Parke East Blvd. Tampa Fl. 33610 Date: June 8,2016 AWARNING - Verify delgrrp.rarnefers and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGEM11.7473 rev. 101031201513EFORE USE. Design valid for use only with MiTekO connectors. Th Is design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the build Ing designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing mot is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria. VA 22314. 1 Tampa, FL 36610 East Coast Truss, Ft. Pierce, FL - 34946, 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:45 2018 Page 1 ID:15v—oaxuPHUsRz5LSGfsyhz93ub-TQ1 CzVGA86f—iRvzExqLCkuoVPNRrOl pAkblr?z8Pfl 0-3-6 H 1 1-3-0 6x6 = 3x3 4X4 1 2 3 Q4 10 26 25 3X3 11 4X6 2-0-1 F:LI-2 4X4 3x3 3X3 3x3 3x3 4 5 6 7 8 4X4 = 3x6 FP = 4x4 9 10 11 Scale = 1:39.7 3X3 =6x6 12 13 15 14 3X6 11 3X6 11 U3 0 '�3p 1�9 9:a-6 ltO­56 ij��-5 -5-6.13 5 1 15-JI n - 10 2-6-J 10-1 1�1 2 -0 0-0 02 2-1.1 2-1-1) 2-1. 24 23 22 21 20 19 18 4X4 5X8 =3x8 M1 8SHS rP 3X6 11 17 16 5x8 4— LOADING (PSf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.87 Vert(LL) -0.48 19-20 >548 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.00. BC 0.91 Vert(CT) -0.66 19-20 >398 240 M18SHS 244/190 BCLL 0.0 Rep Stress Incr YES VVB 0.78 Horz(CT) -0.12 13 n/a n1a BCDL 5.0 Code FBC2017fTP12014 Matrix-S Weight: 131 lb FT = O%F, O%E LUMBER - BRACING. I UP CHORD 2X4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, BOTCHORD 2x4 S P No. I (flat) *Except* except end verticals. 17-23: 2x4 SP No.2(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 1=1204/0-2-13,13=1204/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-3=-1 269/0, 3-4=-3149/0, 4-5=-4705/0, 5-6�5462/0' 6-7�5684/0, 7-8=-5461710, 8-9=-4704/0,9-11=-3149/0,11-13=-1269/0 BOTCHORD 24-25=0/2333,23-24=0/4040,21-23=0/5218,20-21=0/5684,19-20=0/5684,il8-19=0/5684, 17-18=0/5214,16-17=0/4041, 15-16=0/2333 WEBS 6-20=-325/350, 7-19=-330/425, 1-25=0/1 646, 3-25=-1 486/0, 3-24=011 135, 4124=-1 238/0, 4-23=0/904, 13-15=011 646, 11-15�1 486/0, 11-16=0/1 135, 9-16�1 239/0, 9il 7=0/90 1, 5-23=-696/0, 5-21 =0/491, 6-21 =-710/178, 7-18=-7491185,, 8-18=0/511, 8-171-691/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diag6nal or vertical web shall not exceed 0.500in. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cert 6634 604 Parke East Blvd. Tampa FL 33610 Date: June 8,2018 A WARNING -Verify design parameters and READ NOMS ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev, 1010312015 BEFORE USE. Design valid for use only with MiTek4D connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorpa rate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSI1TPI1 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job 'Lu2s3sA TrussType oty Ply Thiel Res. TF Tl 4251812 !136062 Floor Job Reference (optional) O.Z4U51VIdYZ,4,4UIOiviiieKinausiries,inc. t-nJun t$U[:3V:4fZUlb Pagel ID:15v—oaxuPHUsRz5LSGfsyhz93ub-Qp9yOAlRgiVixl3MLMsqH9-8DC3—JvZ6d24Pwuz8Pfg 0-3-6 H 1 1-3-0 2-0-1 PI-131 01�11cale = 1:39.6 6x6 = 3x3 4x4 1 2 0 4X4 = 4x4 3X3 3X3 3x3 3x3 3x6 FP = 4X4 3x3 =6x6 A A I — 26 25 24 23 22 21 20 19 18 17 16 15 14 3X3 11 4x6 4X4 3x8Ml8SHSFP 3x6 3X6 11 5X8 44 4x6 = 3X3 11 3X6 3X6 11 5X8 = 6 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.85 Vert(LL) -0.47 19-20 >552 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.90 Vert(CT) -0.65 19-20 >401 240 M18SHS 244/190 BCLL 0.0 Rep Stress Incr YES WE 0.78 Horz(CT) -0.12 13 n/a n/a BCDL 5.0 Code FBC2017fTP12014 Matrix-S Weight: 131 lb FT = O%F, O%E LUMBER- BRACING. TOPCHORD 2x4 SP No.2(flat) iTOPCHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, BOTCHORD 2x4 SP No. 1 (flat) *Except* except end verticals. 17-23: 2x4 SP No.2(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. VVCDO 2x4 SP No.3(flat) REACTIONS. (lb/size) 1=1200/0-2-13,13=1200/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-3=-126510, 3-4=-3138/0, 4-5=-4686/0, 5-6=-5436/0, 6-7=-5650/0, 7-8=-544110, 8-9�468510, 9-11 =313810, 11-13=-1 265/0 BOTCHORD 24-25=0/2325, 23-24=0/4025, 21-23=0/5195, 20-21=0/5650, 19-20=0/5650,118-19=0/5650, 17-1 8=0/5190, 16-17=0/4026, 15-16=0/2325 WEBS 6-20=-328/354,7-19=-334/428,1-25=0/1641. 3-25=-1481/0,3-24=0/1130, 4L24=-1233/0, 4-23=0/898,13-15=0/1640,11-15�1481/0,11-16=0/1130, 9-16�1234/0,9-17=0/895' 5-23=-691/0, 5-21 =0/490, 6-21 =-705/183, 7-18�744/190, 8-1 8=0/510, 8-17--'686/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Provide mechanical connection (by others) oftruss to bearing plate atjoint(s) 1. 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Walter P. Finn PE No.22839 MiTsk USA, Inc. FL Ced 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: June 8,201 E WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MrrekV connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not 0 truss system. Before use, the building designer must verify the applicability ofdesign parameters and properly Incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing pal* is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing offrusses and truss systems, see ANSffTPfl Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 LI 4 Job Truss Type ci�ty Res. J36062 TF'Lu3ss �Floor �PIYTI`iiel T14251813 Faqt ConO Tin— Pt Pi--e FL - 34946 J, lob Reference (optional) 7 U­v 5 May 24 2016 lviffek industries, inc. Fri Jun 8 07:39:47 20its Page 1 ID:[Sv—oaxuPHUsRz5LSGfsyhz93ub-Qp9yOAARg�W3MLMsqH9—K4CHgJ4X6d24PWuz8Pfg 0-1-8 1 31 0-11-5 2 1x4 1-2-6 3 �48 Scale = 1:7.7 3XS = 1 3X6 = LOADING (psf) SPACING- 2-0-0 CS1. DEFIL. in (loc) Ildefl Ud TCLL 40.0 Plate Grip DOL 1.00 TC 0.09 Vert(LL) -0.00 5 >999 360 TCDL 10.0 Lumber DOL 1.00 BC 0.02 Vert(CT) -0.00 5 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.08 Horz(CT) 0.00 4 n/a n/a BCDL 5.0 Code FBC2017/TP12014 Matrix-P LUMBER- I BRACING - 8 3x6 = PLATES GRIP MT20 2441190 Weight: 22 lb FT = O%F. O%E 1UPCHORD 2x4SPNo.2(flat) i TOP CHORD Structural wood sheathing directly applied or 3-3-3 oc puffins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(fat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. I REACTIONS. (lb/size) 6=129/1-0-0,4=15110-7-4 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Plates checked for a plus or minus 0 degree rotation about its center. 2) Recommend 2x6 strong backs, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) CAUTION, Do not erect truss backwards. 4) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. I AWARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the 6pplicability of design parameters and properly Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage, For general guidance regarding the fabrication, storage. delivery, erection and bracing of trusses and truss systems, see ANSI1TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. YValter P. Finn PE No.22839 MiTek USA, Inc. FL Ced 8634 6904 Parke East Blvd. Tampa FL 33610 Date: MR, MiTek' 6904 Parke East Blvd. Tampa, FL 36610 June 8,2018 LI f Job Truss Truss Type City Ply Thiel Res. J36062 FL7 F loor Till 4251814 � . Job Reference (optional) 0-44V 5 IVIdY 44 IV 10 Wit I eK inaustries, Inc. t-n Jun It Uf:JU:48 201B Pagel ID:15v_oaxuPHUsRz5LSGfsyhz93ub-u?jLbWJ3Rl 1ZZveYv3N3qMWTlcbQ2WRFsiqySKz8Pff 0-3-13 1-3-0 0712 Scale =11 1.4 5x5 3X3 lX4 3X3 5x5 1 2 3 4 1x4 11 5 6 7 9 11 3X3 10 9 3X3 8 3x3 11 3x3 LOADING (psl) SPACING- 2-0-0 CS1. DEFL. in (loc) Ildefi Lid PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.21 Vert(LL) -0.02 10 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.18 Verl(CT) -0.02 10 >999 240 BCLL 0.0 Rep Stress Incr YES WE 0.17 Horz(CT) -0.00 7 n/a n/a BCDL 5.0 Code FBC20171TPI2014 Matrix-S Weight: 35 lb FT = O%F, O%E LUMBER- BRACING- TOPCHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 5-9-8 oc purlins, BOTCHORD 2x4 SP No.2(flat) except end verficals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1 =272/0-2-8, 7=276/0-7-8 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-271/0, 4-5=-271/0, 5-7=-274/0 BOTCHORD 9-1 0=0/271 WEBS 7-9=0/347, 2-1 0=0/347 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. VValtor P. Fin n PE No.22839 MiTak USA, Ini. F1 Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Date: June8,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with Mi rekS connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek* fabrication. slorage, delivery, erection and bracing oftrusses and truss systems. see ANSUTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Type Qty Ply Thiel Res. ]Truss 536062 FI-9 Floor 1 T14251815 TJob ob F Reference (optional) I[E tj.zzu s may Z4 iM ki mi I eK Industries, Inc. Fn Jun 8 07:39:49 2018 Page 1 ID:[5v_oaxuPHUsRz5LSGfsyhz93ub-MCHjpsJhCLgQB3DkTnu]Ma3c5OvmnxhP5MZV—mz8Pfe 0-1-8 H i 0-11-7 1-5-10 1-3-0 001cale = 1:15.8 1 3X6 = 2 1X4 11 33x3 = 43x3 = 3x6 5 3x8 = 1 3X6 = 12 3X6 LOADING (psf) SPACING- 2-0-0 CS1 ' i DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.38 Vert(LL) -0.02 8 >999 360 MT20 244/190 TCDL 10.01 Lumber DOL 1.00 BC 0.30 Vert(CT) -0.03 8 >999 240 BCLL 0.0, Rep Stress Incr YES WE 0.29 Horz(CT) 0.01 6 n/a n1a BCDL 5.0 Code FBC2017/TP12014 Matrix-S Weight: 47 lb FT = O%F, O%E LUMBER- IBRACING- TOP CHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end Verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. �lb/size) 10=419/1-0-0,6=442/0-74 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-10=-434/0.5-6�436/0,1-2�624/0,2-3�624/0,3-4�1015/0,4-5=-552/O BOTCHORD 8-9=0/995, 7-8=0/997 WEBS 5-7=0/617, 4-7=-543/0, 3-9=-42710,1-9=0/601 NOTES- 1) Plates checked for a plus or minus 0 degree rotation about its center.- 2) Recommend 2xG strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) CAUTION, Do not erect truss backwards. 4) Waming: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Walter P. Finn PE No.22639 MiTek USA, Inc. Fl. Carl 6634 60D,4 Parke East Blvd. Tampa FL 33610 Dat6: June 8,2018 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,711-7473 rev. 1010312015 BEFORE USE. Design valid for use only with IvIrrek(D connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system, Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall nil' building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type oty Ply Thiel Res. J36062 ZCJ1 Jack -Open 4 1 T14 Job Reference (optional) Gr Fu 8.220 s May 24 2018 MITek Industries, Inc. Fri Jun 8 07:39:50 2018 Page 1 ID:15%L_oaxuPHUsRz5LSGfsyhz93ub-qOr5OCKJzeHHoDox1 UQXvncsTQITWSVYKOJ3WDz8Pfd 1-4-8 14-8 Scale = 1:7.3 2X3 14-8 LOADING (psf) SPACING- 2-0-0. CS1. DEFL. in (loc, 11clell Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 002 _0,00 Vert'LL, 8 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 EIC 0.02 Vert(CT) -0.00 8 >999 180 8CLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n1a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -MP Weight: 4 Ib FT=O% LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 2=33/Mechanical, 3=14/Mechanical, 1=103/0-4-0 Max Horz 1 =46(LC 8) Max Uplift 2=-31(LC 8), 3=8(LC 8), 1=-39(LC 8) Max Grav 2=33(LC 1), 3=17(LC 3), 1=103(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. BRACING - 1TOP CHORD Structural wood sheathing directly applied or 1-4-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3, 1. Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: June 8,2018 ,&WARNING - V-1ify d--19- P....ters.nd READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(D connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. L . ee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Thiel Res. � T14251817 J36062 ZEJ1A Jack -Open 1 1 Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:50 2018 Page 1 ID:15v_oaxuPHUsRz5LSGfsyhz93ub-qOr5OCKJzeHHoDox1 UQXvncsYQIXWSVYKOJ3VVDz8Pfd 1-2-3 ce 16 6 Scale = 1:6.9 2X3 1-0-81 -3 1-0-8 1 LOADING (ps� SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC, 0.01 Vert(LL) -0.00 8 >999 240 MT20 2441190 TCDL 15.0 Lumber DOL 1.25 BC 0.01 Vert(CT) -0.00 8 >999 180 BCLL 0.0 Rep Stress [nor YES WEI 0.00 Horz(CT), -0.00 2 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -MP Weight: 4 lb FT 0% LUMBER- BRACING. TOPCHORD 2x4 SP No.3 I TOP CHORD Structural wood sheathing directly applied or 1-2-3 oc purlins. BOTCHORD 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=94/0-8-0,2=24/Mechanical,3=10/MechanicaI Max Horz 1 =40(LC 8) Max Uplift 1=-36(LC 8),2�25(1_C 8),3=-7(LC8) Max Grav 1=94(LC 1), 2=24(LC 1), 3=12(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- i 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf, h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end v�,dical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) 1, 2, 3. Walter P. Finn PE No.22839 MiTek USA, frie. FL Cod 6634 6904 Parke East Blvd. Tampa FL 33610 Date: June 8,2018 AwARN,NG. Verifycl..Ignp.rann.ters andREAD NOTES ON THIS AND INCLUDED MITEKREFERENCEPAGEMil-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MITak0 connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designermust verify, the applicability of design parameters and property incorporate this design Into the overall buildingdesign. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSfITPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, AJexandda, VA 22314. Tampa, FL 36610 Job russ Type Qty Ply Thiel Res. 0 T �Truiss T14251818 mle Jack -Open 1 Job eference (optional) East Coast Truss, Ft. Pierce, FL - 34946, 1-2-1 I 0!1X0V 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:512018 Page I ID:15v—oaxuPHUsRz5LSGfsyhz93ub-]aPTEYLxkyP8QMM7aCxmR?811qemFvliYg2c3fz8Pfc Scale = 1:6.9 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) Ildefi Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1. 25 TC 0.01 Vert(LL) -0.00 8 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.01 Vert(CT) -0.00 8 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n1a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MP Weight: 4 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOPCHORD Structural wood sheathing directly applied or 1-2-1 oc purlins. BOTCHORD 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 2=24/Mechanical.3=9/Mechanical,1=94/0-6-0 Max Horz 1=39(LC8) Max Uplift 2�24([_C 8), 3�7(!_C 8). 1 �36(!_C 8) Max Grav 2=24(LC 1). 3=1 2(LC 3). 1 =94(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- I 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility ofthe fabricatorto increase plate sizes to account forthese factors. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3. 1. VValter P. Firin PE No,22839 Wak USA; Inc. FL Cert 6634 6904 Parke Easi Blvd. Tampa FL 33610 Date: June 8,2018 ,&WARMING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGEMII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with 10111ek(E) connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a I uss system. Before use. the building designer must verify the applicability of design parameters and properly incorporate this design into the overall HS, bul ! Iding design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the M!Tek' fabdcation, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria. DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Leo Street. Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Tru S Truss Type Qty Ply Thiel Res. J36062 TZEJs? C Jack -Open T14251819 Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:52 2018 Page I ID:15v — oaxuPHUsRz5LSGfsyhz93ub-mnzrRuMZVGX?2WxJ8vS?—ChC2D—?—M?mKoAb5z8Pfb 1-0-11 Scale = 1:6.7 LOADING (psf) SPACING- 2-0-0 CS1 DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.01 Vert(LL) -0.00 4 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.01 V.rt(CT) -0.00 4 >999 180 BCLL 0.0 Rep Stress Incr YES WI3 0.00 Horz(CT) -0.00 2 n1a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -MP Weight: 3 lb FT = 0% LUMBER- BRACING- TOPCHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 1-0-11 oc purlins. BOTCHORD 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 2=19/Mechanical, 3=7/Mechanical, 1=9010-6-0 Max Horz 1=36(LC8) Max Uplift 2=-20(LC 8), 3�6([_C 8), 1=-34(LC 8) Max Grav 2=1 9(LC 1). 3=9(LC 3). 1 =90(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D: Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed; end v I ertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) As requested, plates have not been designed to provide for placement tolerances or rough. handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3, 1. VValter P. Finn PE No.22839 MiTok USA, Inc. Fl. Cod 6634 6904 Parke East Blvd. Tampa FL 33610 Date: June8,2018 ,&WARNING. Vedfyd..Ign,.,a..ters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTeke connectors. This design is based only upon parameters shown, and Is for an individual building component, not truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall aullding design. Bracing Indicated is to prevent buckling of Individual truss web a d1or chord members only. Additional temporary and permanent bracing Nil' b n is always required for stability and �o prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erect on and bracing of trusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute. 218 N. Lee Street. Suite 312. Alexandra, VA 22314. 6904 Parke East Blvd. Tampa, FIL 36610 Job —TZEJ515D u ru s Type aty Ply e Thi I Res. !136062 rJ..sk- open I 1 � T1 4251820 Job Reference (optional) --- ---- o.zzv s may zq zu I tj m I I elt I nauStries, in c. 1-- n Jun 8 07:39:53 2018 Page I 0-11-4 ID:[5v—oaxuPHUsRz5LSGfsyhz93ub-EzWEfEMCGZfsfgWfidzEXQEMpdKAjpF_LXj7Yz8Pfa E-1 1-4 6 2X4 = W 4 6 Scale = 1:6.4 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/defi Lid PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25- TC 0.01 Vert(LL) -0.00 4 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.02 Verl(CT) -0.00 4 >999 180 BCLL 0.0 Rep Stress Incr YES WEI 0.00 Horz(CT) -0.00 3 n1a n/a BCDL 10.0 Code FBC2017frPI2014 Matrix -MP Weight: 3 lb FT = 0% LUMBER- j BRACING. TOPCHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 0-11-4 oc purlins. BOTCHORD 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1 =51/0-6-0, 2=27/Mechanical, 3=23/Mechanical Max Horz 1=31(LC8) Max Uplift 1 �1 9(LC 8), 2=-20(LC 8), 3=-1 4(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf*, h=24ft; 8=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2, 3. Walter P. Finn PE No.22839 MiTek USA, Inc, FL Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Date: June 8,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGEMI1.7473,., 1010312015 BEFORE USE. Design valid for use only with MiTekS connectors. This design Is based only upon parameters shown, and is for an Individual building component, not I truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication. storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job T S Truss Type Qty Thiel Res. �36062 rZEJS2 Jack -Open 1 �Ply T14251821 Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:53 2018 Page 1 ID:15v_oaxuPHUsRz5LSGfsyhz93ub-EzWEfEMCGZfsfgWVidzEXQEL7dJojpF_A_Xj7Yz8Pfa 2-5-4 r' 2-5-4 LJE=0IUINr_M r-%[=WUr_0 1 . 2x3 = VFRS ONLY, PER BUILDING I Y1­'ItAL IN THIS JOB. Scale = 1:9.6 0-4-8 1 2-0-12 1 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (10c) I/defl Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TI 0:112 Vert(LL) -0.00 4 >999 240 MT20 2441190 TCDL 15.0 Lumber DOL 1.25 BC . 1 Vert(CT) -0.00 7 >999 180 3CLL 0.0 Rep Stress Incr YES W8 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -MP Weight: 8 lb FT = 0% LUMBER - BRACING. TOPCHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-5-4 oc purlins. BOTCHORD 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=177/0-6-0, 2=71 /Mechanical, 3=13/Mechanical Max Horz 1=81(LC8) Max Uplift 1 =69(LC 8), 2�67(!_C 8), 3=-2(LC 8) Max Grav 1 =1 77(LC 1). 2=71 (LC 1), 3=29(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown NOTES. 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end ve.kical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 - 2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2, 3. Walter P. Finn PE No.22839 MiTek USA, 16i, FL Cod 8634 6904 Parke East Blvd. Tampa Fl. 33610 Date: June8,2018 A WARNING - V-&Y design I.ranrefers and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGEM11.7473 rev. 101021201S BEFORE USE, Design valid for use only with MlTekS connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall sot building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB.89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 I Job Truss Truss Type Qty Ply Thiel Res. J36062 ZEJ2A Jack -Open T14251822 Job Reference (optional) LOADING (pso TCLL 30.0 TCDL 15.0 BCLL 0.0 BCDL 10.0 LUMBER - TOP CHORD 2x4 SP N0.3 BOT CHORD 2x4 SP No.3 fl il 2X3 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress [nor YES Code FBC2017rrPI2014 CS1. TC 0.13 BC 0 14 WB 0 00 Matrix -MP REACTIONS. (lb/size) 1=124/0-6-0, 2=82/Mechanical, 3=41 /Mechanical Max Horz I =77(LC 8) Max Uplift I =-48(LC 8), 2=66(LC 8). 3=-1 6(LC 8) Max Grav 1=124(LC 1), 2=82(LC 1), 3=43(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown 0'44L) 5 Ivlay z4 zu its Nit I eK inaustries, Inc. t-n Jun 5 Uf:39:54 ZU18 Page 1 ID:]5v—oaxuPHUsRz5LSGfsyhz93ub-j94csaNqOtniHq5iGKUT3dmWnleTSGV8EeHGf—z8PfZ 2-3-12 DEFL. Vert(LL) Vert(CT) Horz(CT) BRACING - TOP CHORD BOTCHORD Scale = 1:9.3 T Z: 6 in (loc) I/defl Lid PLATES GRIP -0.00 6 >999 240 MT20 244/190 -0.00 6 >999 180 -0.00 2 n/a n/a Weight: 7 lb FT = 0% Structural wood sheathing directly applied or 2-3-12 oc purlins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- I 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizos to account for these factors. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 fall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2, 3. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Date: A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MrrekV connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Dal' building design. Bracing indicated is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication. storage, delivery, erection and bracing oftrusses and truss systems, see ANSIrrPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 1 6904 Parke East Blvd. Tampa. FL 36610 June 8,2018 Job Truss Truss Type Qty Ply Thiel Res. 336062 ZEJ2B Jack -Open 1 dJob T1 4251823 Reference (optional) Last UoaSt Truss, Ft. Pierce, FL - 34946, ti 2x3 = 1-11-6 8.220 s May 24 2018 MiTek Industries, Inc. I'd Jun 8 07:39:55 2018 Page 1 ID:]5v—oaxuPHUsRz5LSGfsyhzg3ub-BMe-3wOSnBvav_gupl?icrJibRDCBjIHTIOqCQz8PfY Scale = 1:8.6 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) Ildefl Lid PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.06 Vert(LL) -0.00 8 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.05 Vert(CT) -0.00 8 >999 180 BCLL 0.0 Rep Stress Incr YES WEI 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MP Weight: 6 lb FT = 0% LUMBER- 13RACING- TOP CHORD 2x4 SP No.3 TOP CHORD �BOT Structural wood sheathing directly applied or 1-11-6 oc purlins. BOTCHORD 2x4 SP No.3 CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=132/0-8-0, 2=57/Mechanical, 3=24/Mechanical Max Horz 1 =66(LC 8) Max Uplift 1 �51 (LC 8), 2=51 (LC 8), 3=1 O(LC 8) Max Grav 1 =1 32(LC 1). 2=57(LC 1), 3=29(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd.=132mph; TCDL=9.Opsf: BCDL=3.0piSf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) oftruss to bearing plate capable ofwithstanding 100 lb uplift atjoint(s) 1, 2, 3. Walter P. Finn PE No.22839 MiTak USA ' Inc. F1 CoA,6634 6004 Parke East Blvd. Tampa I Fl. 33610 Date: June 8,2018 a WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473., 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use. the building designer must ver[fythe applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Addilignal temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIrrPI1 Quality Criteria, DSB.89 and BCSf Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Type Qty Ply Thiel Res. �36062 , TTErujss Z 2C �Truss Jack -Open 1 T14251824 � Job eference (optional) 1-11-3 164v 5 ividy 4,+ zu i a ivii I eK inaustnes, Inc. t-n Jun 6 U7:39:55 2018 Page I ID:15v—oaxuPHUSRz5LSGfsyhz93ub-BMe-3wOSnBva%�_gupl?icrJicRODBjIHTIOqCQz8PfY Scale = 1:8.5 2X3 g:4 1-11-3 1-6-11 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25. TC 0.06 Vert(LL) -0.00 8 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.05 Vert(CT) -0.00 8 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n1a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -MP Weight: 6 lb FT 0% LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/ ' size) 2=57/Mechanir-al, 3=23/Mechanical, 1=131/0-6-0 Max Horz 1 =65(LC 8) MaxUplift 2=50(l-C8),3�11)(1-C15), 1=-50(LC8) Max Gram 2=57(LC 1), 3=28(LC 3). 1 =1 31 (LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. BRACING- TOPCHORD Structural wood sheathing directly applied or 1-11-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES. 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.dpsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility ofthe fabricatorto increase plate sizes to account forthese factors. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with anylother live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3. 1. Walter P. Finn PE No.22839 MiTek USA Inc. F1 Cod 6634 6904 Parlfa&st Blvd. Tampa FL 33610 Date: June 8,2018 AwARNING - V-1ify design P.I.M.t.. andREAD NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with M7tekQD connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use. the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Met building design. Bracing indicated is to prevent buckling of indivildual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job S russ ype Qty Ply Thiel Res. J36062 TZEJS2D J ack-Open I I T14251825 lob Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, �1 2X4 = 2-5-2 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:56 2018 Page I ID:[5v—oaxuPHUsRz5LSGfsyhz93ub-fYCMHFP4YU 1 RW8F4NIXx82rr6rLJwA—RiymNksz8PrX Scale = 1:8.1 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/defi Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.14 Vert(LL) -0.00 4 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 112 Vert(CT) -0.00 4 >999 180 BCLL 0.0 Rep Stress Incr YES WB :0" Horz(CT) -0.00 2 . n/a n/a BCDL 10.0 Code FBC2017rrP[2014 Matrix -MP Weight: 8 lb FT=O% LUMBER- 13RACING. TOPCHORD 2x4 SP No.3 TOPCHORD Structural wood sheathing directly applied or 2-5-2 oc purlins. BOTCHORD 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=186/0-8-0, 2=68/Mechanical, 3=7/Mechanical Max Horz 1=60(LC8) Max Uplift 1=-83(LC 8), 2=-58(LC 8) Max Grav 1=186(LC 1), 2=68(LC 1), 3=25(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf, h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=O.l 8: MWFRS (directional); cantilever left and right exposed ; end Vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0p�f on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 6634 6904 Parke Easi Blvd. Tampa Fl. 33610 Data: June 8,2018 AWARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGEMII-7473 rev. 1010312015 BEFORE USE -- Design valid for use only with MrreklD connectors. This design Is based only upon parameters shown, and is for an individual building component. not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall Hv 11' buildingdesign. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For g6neral guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPH Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Instilute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FL 36610 Job russ Truss Type Qty Ply Thiel Res. ZEJ3 T Jack -Open 2 T1 4251826 Job Reference (optional) O.Z4U S May 44 ZU 1 ?J mi I eK Inaustries, Inc. I-n Jun 8 07:39:57 2018 Page 1 ID:15v_oaxuPHUsRz5LSGfsyhz93ub-7kmkUbQiJoAH8HqHxS2AhGO—uEfrfdEaxcVxGJz8PfVV 3-4-8 34-8 Scale= 1:11.5 2x3 � 1 0-4-8 3.0-0 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) Udefl Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.26 Vert(LL) -0.01 4 >999 240 MT20 2441190 TCDL 15.0 Lumber DOL 1.25 BC 0.19 Vert(CT) -0.01 3-7 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MP Weight: 11 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD BOT CHORD 2x4 SP No.3 BOTCHORD REACTIONS. (lb/size) 1 =218/0-4-0. 2=1 13/Mechanical, 3=34/Mechanical Max Horz 1 =1 13(LC 8) Max Uplift I =-85(LC 8). 2=1 OO(LC 8), 3=-7(LC 8) Max Grav 1=218(LC 1), 2=113(LC 1), 3=52(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Structural wood sheathing directly applied or 3-4-8 oc purlins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.0p'sf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D: Encl., GCpi=0.18: MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) As requested, plates have not been designed to provide for placement tolerances or rough lhandling and erection conditions. It is the responsibility ofthe fabricator to increase plate sizes to account for these factors. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas wfiere a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2, 3. Walter P. Fin ri PE No.22839 MiTak USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: June 8,2018 AWARNING - ye rify design parameters and READ NOTES ON'THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design Is based only upon parameters shown, and is for an individual building component. not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing Nil' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and Bost Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Tfu S Tni"pe Qty Ply Thiel Res. J36062 FZEJs3A �Jack-Open Tl 4251827 JlTob Reference (optional) il 2X3 = 'J.z zu s may Z4 ZU16 mi I eK Industries, Inc. Fri Jun 8 07:39:57 2018 Pagel ID:15v—oaxuPHUsRz5LSGfsyhz93ub-7kmkUbQiJoAH8HqHxS2AhGO_qEeEfdEaxcVxGJzBPfW Scale = 1:11.7 '0-4-8 3-0-14 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Well Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.27 Vert(LL) -0.01 4 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.20 Vert(CT) -0.01 3-7 >999 180 EICLL 0.0 Rep Stress Incr YES WE 0.00 Horz(CT) -0.00 2 n/a nta BCDL 10.0 Code FBC2017rrPI2014 Matrix -MP Weight: 11 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOPCHORD BOT CHORD 2x4 SP No.3 BOTCHORD REACTIONS. (lb/size) 1 =228/0-6-0, 2=1 13/Mechanical, 3=31 /Mechanical Max Horz 1 =1 15(LC 8) Max Uplift I =-89(LC 8). 2=-1 01 (LC 8), 3=-5(LC 8) Max Grav 1=228(LC 1), 2=113(LC 1), 3=51(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Structural wood sheathing directly applied or 3-5-6 oc purlins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf, h=24ft; 8=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl.. GCpi=0.18; MWFRS (directional); Cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility ofthe fabricatorto increase plate sizes to account forthese factors. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except at=lb) 2=101. Walter P. Fin n PE No.22839 MiTak USA, Inc. Fl. Cod @034 6904 Parke East Blvd. Tampa K 33610 Date: June8,2018 AWARNING - V.11ty cf.sigp.ramefers and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown. and Is foran individual building component, n I a truss system. Before use, the building designer must verify the applicability of design parameters and properiy=orate this design into the 0 building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Ad overall Nil' Is always required for stability and to prevent collapse with possible personal injury and property damage. For g�neral I temporary and permanent bracing russ systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. fabrication, storage, delivery, erection and bracing of trusses and I guidance regarding the M!Tek' Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job T s Truss Type Qty Ply � Thiel Res. T14251828 ZEJ3B Jack -Open 1 Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:58 2018 Page 1 ID:15v_oaxuPHUsRz5LSGfsyhz93ub-bwK7!xQK46[8mRPTVAZPETxBXe?dO4Uk9GFUoiz8PfV 1 il 2x3 = 2-8-5 1i Scale = 1:10.1 LOADING (pso SPACING- 2-0-0 CS1 DEFL. in (loc) I/defi Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.14 Vert(LL) -0.00 7 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25- EIC 0.13 Vert(CT) -0.00 3-7 >999 180 EICILL 0.0 Rep Stress Incr YES WEI 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -MP Weight: 9 lb FT=O% LUMBER- BRACING- TOPCHORD 2x4 SP No.3 TOPCHORD Structural wood sheathing directly applied or 2-8-5 oc purlins. BOTCHORD 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=190/0-6-0, 2=82/Mechanical, 3=18/Mechanical Max Horz I =89(LC 8) Max Uplift 1 =-73(LC 8), 2=-75(LC 8), 3=-3(LC 8) Max Grav 1 =1 90(LC 1), 2=82(LC 1), 3=35(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=24ft; 13=4511; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 lost bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2, 3. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cott 6634 6§04 Parke East Blvd. Tampa FL 33610 Date: June 8,2018 AwARN,No. �erlfy design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473ray. 1010312015 BEFORE USE. Design valid for use only with MiTelk(D connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrusses and truss systems. see ANSIrTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Tru a Truss Type Qty Ply Res. 'J36062 ZEJ4 Jack -Open I I TThiel T14251829 Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, 2x3 = �4-2-8 8.220 a May 24 2018 MlTek Industries, Inc. Fri Jun 8 07:39:59 2018 Page 1 ID:]5v—oaxuPHUsRz5LSGfsyhzg3ub-37uVvHRyrPQ?Nb—f2t4emhTl-2JQ7Xkt0w—lLBzBPfU Scale = 1: 13.2 0-4-8 3-10-0 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defi Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.42 Vert(LL) -0.01 3-7 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.28 Vert(CT) -0.02 3-7 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 2 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matdx-AS Weight: 13 lb FT=O% LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 1=269/0-6-0,2=145/Mechanical,3=42/MechanicaI Max Horz 1=141(LC8) Max Uplift 1=-105(LC 8),2=-128(LC 8), �=-6(!_C 8) Max Grav 1=269(LC 1), 2=145(LC 1), 3=66(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied. NOTES- 1) Wind: ASCE 7-10: Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf: BCDL=3.Opst, h=24ft; 8=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (direct!6nal); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility ofthe fabricatorto increase plate sizes to account forthese factors. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except at=lb) 1=105, 2=128. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. VValter P. Finn PE No.22839 MiTak USA, Inc. FL Cart 6634 004 Farke East Blvd. Tampa FL 33610 Date: June 8,2018 AwARN,No -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(ll) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is for MiTek' always required stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIrrPl1 Quality Criteria, DSE-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 21 8 N. Lee Street, Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa, FL 36610 Job _TZEJs4A Tru S russ ype e Thi I Res. J36062 ack-Open �J rQ) 1 [ly T14251830 � Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, il 2x3 = 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:39:59 2018 Page 1 3-9-13 ID:15v—oaxuPHUSRz5LSGfsyhz93ub-37uVvHRyrPQ?Nb—f2t4emhTJ22KO7XktOw-1 LBz8PfU 3-9-13 Scale = 1: 12.4 1 0-4-8 3-5-5 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.35 Vert(LL) -0.01 4 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.25 Vert(CT) -0.01 3-7 >999 180 EICLL 0.0 Rep Stress Incr YES WEI 0.00 Horz(CT) -0.01 2 n/a n/a BCDL 10.0 Code FBC2017rrP]2014 Matrix -MP Weight: 12 lb FT=O% LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 1 =248/0-6-0, 2=1 28/Mechanical, 3=37/Mechanical Max Horz 1=128(LC 8) Max Uplift I =-97(LC 8), 2=1 14(LC 8), 3�6(1_C 8) Max Grav 1=248(LC 1), 2=128(LC 1). 3=69(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied or 3-9-13 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=24ft; 8=45ft; L=24ft; eave=4ft; Cat, 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vei�tical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any 6ther live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except (ft=1b) 2=1 14. Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cart 6634 604 Parke East Blvd. Tampa Fl. 33610 Date: June 8,2018 WARNING -Verify design parameters and READ NOTES ONTHIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 ra� 1010312015 BEFORE USE. Design valid for use only with MiTek0conneclors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the Welk' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FL 36610 Job Truss. 'us Type Qty Ply Thiel Res. J36062 ZEJ48' �J..ks op.. T1 4251831 I — ^ Job Reference (optional) I 2X3 = 3-8-5 u S --y z4 Zu I Is Nil I eK industries, Inc. Fn Jun 8 07:40:00 2018 Page 1 ID:15v—...UPHUSRz5LSGfsyhz93ub-XJRt7dSbcjYs?[YscbbtJuOT1 SeNs—Odakbtez8PFr 1� Scale = 1:12.2 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) Vden Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.40 1 Vert(LL) 0.02 3-6 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.03 3-6 >999 180 EICLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FEIC20171TPl2014 Matrix -MP Weight: 12 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD BOTCHORD 2x4SPNo.3 BOTCHORD REACTIONS. (lb/size) 1=20010-6-0, 2=138/Mechanical, 3=62/Mechanir-al Max Horz 1=124(LC 8) Max Uplift 1 �78(LC 8). 2�1 12(LC 8), 3�1 9(LC 8) Max Grav 1=200(LC 1). 2=138(LC 1), 3=70(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Structural wood sheathing directly applied or 3-8-5 oc purlins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- I 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=24ft; 6=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=11.60 2) As requested, plates have not been designed to provide for placement tolerances or rough landling and erection conditions. It is the responsibility ofthe fabricatorto increase plate sizes to account forthese factors. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except at=lb) 2=1 12. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Carl 66.34 8904 Parke East Blvd. T ampa FL 33610 Data: June8,2018 A WARNING - Verify dsig. parameters and READ NOTES ON THIS AND iNcLuDEDmITEK REFERENCE PAGE M11.7473 rev. 1010312015 BEFORE USE. Design valid for use only with Mi7ekID co n n actors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the MiTek' fabrication, storage. delivery, erection and bracing oftrusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Mexandria, VA 22314. Tampa, FL 36610 Job T ss Truss Type QtY Ply Thiel Re J36062 ZEJ4C Diagonal Hip Girder 1 T14251832 Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, 3X4 = 3-8-8 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:40:01 2018 Page 1 ID:15v_oaxuPHUsRz5LSGfsyhzg3ub-OV?FKzTDNlgjdv72AI66r6Zhws1 pbREArET8P4z8PfS Scale = 1:9.0 . 0-5-9 1 1 3-2-14 1 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Ildefl Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.20 Vert(LL) -0.01 3-8 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.16 Vert(CT) -0.01 3-8 >999 180 BCLL 0.0 Rep Stress Incr NO' WEI 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 11 lb FT = 0% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 3-8-8 oc purlins. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1 =231/1-3-11, 2=1 20IMechanical, 3=50/Mechanical Max Horz 1 =82(LC 4) Max Uplift 1 =-1 35(LC 4), 2=1 03(LC 4). 3=21 (LC 4) Max Grav 1=231(LC 1), 2=120(LC 1), 3=60(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- I 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=W.VPST. t5kUL=.3.upsf:, h=24ft; 13=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) 3 except et=lb) 1=135, 2=103. 7) "NAILED" indicates 2-12d (0.1 48"x3.25") toe -nails per NDS guidlines. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (8). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate lncrease=1.25 Uniform Loads (plf) Vert: 1-2�90, 3-4=-20 Concentrated Loads (lb) Vert: 11 =-3(B) 1 2=4(F) Walter P. Finn PE No.22839 MiTak USA, Inc. Fl. Carl 6034 6904 Parke East Blvd. Tampa FL 33610 Date: June 8,2018 AWARNING Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job _TZEJS5 T'U S Truss Type Qty Ply Thiel Res. J36062 JJack-Open 1 T1 4251833 Job Reference (optional) uss, Ft. Pierce, FL - 34946, il 2X3 = 8.220 s May 24 2018 MITek Industries, Inc. Fill Jun 8 07:40:012018 Page I 1-10 ID:15v—oaxuPHUsRz5LSGfsyhz93ub-OV?FKzTDN1 gjdv72A[66r6ZbKs—LbREArET8P4z8PfS 1-10 1 Scale = 1:14.8 0.4-8 4-7-2 1 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defi Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.62 Vert(LL) 0.03 3-7 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.04 3-7 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 2 n/a n/a BCDL 10.0 Code FBC20171TP12014 Matrix -AS Weight: 16 lb FT = 0% LUMBER- 9RACING- TOPCHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied. BOTCHORD 2x4 SID No.3 BOTCHORD Rigid ceiling directly applied. REACTIONS. (lb/size) 1 =309/0-6-0, 2=1 77/Mechanical, 3=53/Mechaniral Max Horz 1 =1 67(LC 8) Max Uplift I �1 21 (LC 8), 2=-1 54(LC 8). 3=-8(LC 8) Max Grav 1=309(LC 1), 2=177(LC 1), 3=81(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.0psf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Referto girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) oftruss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) 3 except at=lb) 1=121, 2=154. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cort 6634 6904 Parke East�Blvd. Tempe FL 33610 Date: June8,2018 AWARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(ID connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Mal' building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek' fabrication. storage, delivery, erection and bracing oftrusses and truss systems. see ANSUTP11 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa, FL 36610 Job Tru s Truss Type Qty, Ply Thiel Re . S J36062 ZEJ9 Diagonal Hip Girder 1 1 T1 4251834 � Job Reference (optional) aSL �OaSt i WSS, Ft. Her u�, rL - 34946, 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:40:03 2018 Page I ID:]5v_oaxuPHUSRz5LSGfsyhz93ub-yu7?IfUTvewRsDHQHj9axXezafcl3GcTJYyFUyz8PfQ NAILED 3x4 _— 4-9-14 4-0-7 = 1:16.3 0-6-13 4-3-0 4-0-7 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.51 1 Vert(LL) 0.05 5-6 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.54 Vert(CT) -0.07 5-6 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.33 Horz(CT) -0.01 3 n1a n/a BCDL 10.0 Code FBC2017/TP12014' Matrix -MS Weight: 34 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-6-13 oc purlins. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 6-11-8 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=599/0-10-9, 3=1 71 /Mechanical, 5=331/Mechanical Max Horz 1 =1 96(LC 4) Max Uplift 1=-392(LC 4), 3=-149(LC 4), 5=-219(LC 4) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-939/569 BOTCHORD 1-6=-679/865, 5-6=-679/865 WEBS 2-5=-904/71 0 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss is not designed to support a ceiling and is not intended for use where aesthetics are a consideration. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed fora 10.0 psfbottom chord live load nonconcurrent with any 6ther live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord'in all areas wNere a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding- 100 lb uplift at joint(s) except at=lb) 1=392,3=149,5=219. 8) "NAILED" indicates 3-1 Od (0.1 48"x3") or 2-12d (0. 148"x3.25") toe -nails per NDS guidlines. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber lncrease=1.25, Plate lncrease=1.25 Uniform Loads (plo Vert: 1-3=-90, 4-7=-20 Concentrated Loads (lb) Vert: 13=-48(F=-29, B=-1 9) 14=-1 8(F=-1 6, B=-2) 15=-1 6(F=-1 7, B=I) 16=-50(F=-37, B=-1 3) Walter P. Finn PE No.22839 M!Tek USA Inc. F1 Ced 6634 604 Parke'East Blvd. Tampa FL 3*0 Date: June 8,2018 AINARNING -Verify design parameters and READ NOTES ON THIS �ND INCLUDED MITEK REFERENCE PAGE 11111.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(D connectors, This design is based only upon parameters shown, and is for a I n individual building component, not a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall Sol' building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job T ss Truss Type Q�� Qly Ply 'y P7 -n Thiel Res. J36062 p, ZHJ3 Diagonal Hip Girder [2 T I T14251835 1­ — — Job Reference (Optional) 4-8-8 2x4 = 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jun 8 07:40:03 2018 Page I ID:15v_oaxuPHUsRz5LSGfsyhz93ub-yu7?IfUTvewRsDHQHjgaxXe—PfhP3LjTJYyFUyz8PfQ LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Ildef! Ud TCLL 30. 0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) 0.02 3-7 >999 240 TCDL 5 i NO Lumber DOL 1.25 BC 0.22 Vert(CT) -0.03 3-7 >999 180 BCLL Rep Stress Incr NO WE 0.00 Horz(CT) -0.01 2 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -MP LUMEIER- TOP CHORD 2x4 SP NO.2 BOT CHORD 2x4 SP No.2 REACTIONS. (lb/size) 1 =307/0-5-11, 2=1 62/Mechan ical, 3=5 1 /Mechanical MaxHorz 1=112(LC8) Max Uplift I =-I 53(LC 8), 2=-1 28(LC 8), 3�1 O(LC 8) Max Grav 1=307(LC 1), 2=162(LC 1), 3=75(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1: 11.3 PLATES GRIP MT20 244/190 Weight: 14 Ito FT=O% BRACING- TOPCHORD Structural wood sheathing directly applied or 4-8-8 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=24ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp D: Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except Ot=lb) 1=153,2=128. 7) "NAILED" indicates 3-1 Od (0.1 48"xY) or 2-12d (0. 148"x3.25") toe -nails per NDS guldlines. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate lncrease=1.25 Uniform Loads (plo Vert: 1-2=90, 3-4=-20 Concentrated Loads (lb) Vert: 9�8(17=4, B�4) VValter P. Finn PE No.22839 MiTak USA, Iric. Fl. Can 6634 004 Parke East Blvd, Tampa Fl. 33610 Date: June 8,2018 AWARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev� 1010312015 BEFORE USE. Design valid for use only with MiTekaD connectors. This design Is based Only upon parameters shown, and Is for an individual �building component, not a truss system. Before use. the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent bucking of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Symbols PLATE LOCATION AND ORIENTATION 3/;' Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. For 4 x 2 orientation, locate plates 0- 'lid' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSIrFP11: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 0 Numbering System 6-4-8 dimensions shown in It -in -sixteenths I (Drawings not to scale) 6 BOTTOM CHORDS 8 7 3 6 5 0 Elf 0 0 I -- JOINTS ARE GENERALLY NUMBEREDILETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/ILETTERS. PRODUCT CODE APPROVALS CCC-ES Reports: ESR-1 311, ESR-1 352, ESR1 988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design- values are in accordance with ANSI/TPl I section 6.3 These truss designs rely on lumber values established by others. 0 2012 MiTek@ All Rights Reserved mm lei MiTek MiTek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner�ancl all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSIITPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purfins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others 16. Do not cut or after truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI I Quality Criteria.