HomeMy WebLinkAboutBUILDING PLANS5,-0"
91-1
SITTING
Room
\A,15,
A
Prr�,, de Briart Vent Model 415,40-510
encj�ndered flood vent - installed per
ma�ljfacturers recomendations.
1 vent = 20(:) sq. ft. of coverage
Garage = 5,41 sq. ft, - 3 vents required
2
12'- 1,,
B�=:DFIOOM 1�
S-loll
GARAGE
41-0.1
2 4'- -1 "
1 H.B I
r wirdow Schedule
Mark
Size
Window Description
I .
31-11, X 5'-3"
SINGLE HUNG
2.
3 1-11, x 31— 2 "
SINGLE HUNG
3.
2'-2" x 3'-2"
SINGLE HUNG
4.
81-01, x
FIXED GLASS
— ALL Windows to be white ESP aluminum windows with tint.
Provide muntim's and structural mullions per elevations. See
product approval chart for window manufacturer information.
— ALL windows to withstand Pressures stated in Permit
Information Box on these plans.
— ALL windows in bathrooms to be tempered
— ALL windows within 18" of finished floor to be tempered
— unless im act rated. ring windows.
verify al�l masonrg/rough opening sizes prior to orde
Door Schedule
Mark
Size
[Door Description
A
3--o-, x e.,-8-
r-IBERGLASS
5
41-0" X a'— 0 "
GARAGE DOOR
C
12'-0" X 8'-0"
GARAGE DOOR
0
12'-0" X 4`8"
SLIDING GLASS DOOR
E
31-0" X C—S"
20 MIN FIRE DOOR
F
3'-0" X C—S"
SOLID CORE — WOOD
G
2'—B" X 4'-8"
SOLID CORE — WOOD
H
7-4" X 4`151"
SOLID CORE — WOOD
1
2'-4" X 41-8"
SOLID CORE — WOOD — POCKET DOOR
K
2,—o,, X 41-81,
SOLID CORE — WOOD — BI—FOLD
— ALL exterior ors includinmarve drrs to withstand
tnese
c plans.
pressures statels in permit rma ion ox on
— verify all masonry/rough opening sizes prior to ordering
windows.
— See product approval chart on these plans for exterior
door manufacturer information (including garage door)
— Provide one exit door (swing type) that is 3'-0" wide
Minimum and one emergency escape door (not shuttered).
If escape door has glazing then it must be impact resistant
and shall NOT be thru garage. This may be the same door
if it meets both criteria listed above.
BEAL CONCRETE BLOCK AT DOOR AND WINDOW OPENINGS WITH
CONCRETE SEALANT FRIO TO BUCK INSTALLATION PER FBCR 703-8)
First Floor Square Footage
First Floor A/C 512 sq. ft.
Garage 541 sq,
First Floor Total 1053 sq. ft.
Second Floor Square Footage
Second Floor A/C = 9-42 5cj. ft.
Covered Porch Total Ili sq. ft.
Second Floor Total = 1053 so, ft,
Under Roof Square Footage Breakdown
First Floor Total = 1053 sq. ft.
Second Floor Total 1053 f t.
0
FLCOfP,
F
L 4
N
Total Space Under Roof = 210� sq, ft. ... I
TYPICAL NOTES: SCALE 1/4" = 1'-0"
A/C Space Breakdown
1.
Contractor to verify ALL notes and dimensions prior to
First Floor A/C 512 sq. ft.
proceeding with work.
2.
Contractor to STRICTLY enforce ALL OSHA Requirements.
Second Floor A/C 9,42 sq. ft.
3.
ALL Lumber to be used as Beam, Rafters, etc.. . to have
Total A/C space 1,45,4 sq. ft.
a minimum 1,400 P.S.I. fiber stress.
-4.
No dissimilar metals to touch.
S.
ALL Concrete used for slabs shall be min. 2,500 PSI concrete.
Totdi Cubic Volume 11432 sq. ft,
ALL Concrete used for vertical filled cells, cont. tie beams etc.. to
shall be 3,000 P.S.l. concrete and/or 4,000 F.S.I. grout mix
1 -1. ALL ceramic tile surfacLs installed shall conform to ASTM A108.1 thru A108.�,
Drywall at ceilings shall be leveled and attached to bottom chord
A108.1, A118.1, A118.3, A13�.l and A131.1
of trusses with screws per FBC R102.3.5.
be treated.
18. Cement, fiber -cement or glass mata�gpsum backers in accordance with ASTM
1�
ALL wood in contact with concrete shall pressure
C1288, C1325, OR C1118 and inst led I.A.W. manufacturers recommendations shall
8.
ALL wall dimensions are nominal and not finished wall or stud dimensions.
be used as backer for the wall tile in tub areas and wall panels in shower areas.
9.
ALL plumbing fixtures to be low flow.
19. Insulation including facings such as retarders or vapor permeable members installed
10.
Contractor to Provide Drain at water heater in accordance
within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
with the current edition of the Florida Plumbing Code.
shall have a flame spread index not to exceed 25 with an accomparging smoke
11.
Contractor to Provide a 2'-B" wide door at one bathroom for
developed index not to exceed 450 when tested in accordance witF ASTM E 8-4.
handicap accessibility requirements.
Insulation shall comply with F.B.C. R31�. 1
12.
Lowest finished floor to be set by Governing Building Department
20. ALL materials used below base flood elevation must be flood resistant. This is to include
surveyor to set in field.
all wall coverings in garage and elsewhere if applicable.
13.
Wall and Ceiling shall have a flame -spread classification of not greater
21. ALL drawirq� and written material herein constitute original work of this firm and the same or amg part
than 200 per FBC R302.9.1
@ thereof M��Y NOT be duplicated, disclosed, distributed or used in anit manner without written consent
14.
Wall and ceiling finishes shall have a smoke -developed index of not greater
of this firm. Any user thereof, without consent, shall be indebted to his firm for full commissiom,
than 450 per FBC R302.9.2
15.
All exposed attic insulation materials installed on attic floors shall have a critical radiant
flux not less than 0.12 watt per square centimeter. Exposed foam plastic
insulation
materials exposed on the underside of the roof deck or on the attic walls
shall comply
with F.B.0 R31� - see permit info box of code edition
1�.
Gypsum board material shall conform to ASTM C36, C19, C-41S. C51-4, C430, C931
WALL SYMBOL LEGEND
C9(.0, C1002, C1041,C11-11, C1118, C1218, C1395, or C13% and shall be
installed
according to the following: (FBC R102.3.5)
= CBS walls - Fill cells solid with concrete and (1) 45 bar Vert at 40"
DrWwall
Location
Orientation
Framing
Member
Max. spacing
of Fasteners
Nail sizing options for
dr
Thickness
a,,ng
Ma imum
x
installation of wall into
wood framing mem er3
2" x min. thickness
Ceiling
Perpendicular
2,41,
T,
12"
13ga 1 3/8" long with 19/64" head
OR
0.098" diameter x 1 1/4" long
ammular-rimged or 5d cooler mail
OR
walls
E ther
1(.11
81,
161,
0.080" dia. x 1 5/8" long with
D�rection
15/44" head
OR
Graum board nail 0.086" dia.
x 5/8" with 9/32" head
Ceiling
Perpendicular
2,q
7
121,
13ga 1 5/8" long with 19/4-4" he6,d
OR
0.098" diameter x 1 3/8" long
amnular-ringed or 4d cooler mail
—
OR
Walls
81,
16,
0.092" dia. x 1 1/8" long with
1/4" head
OR
Gjpsum board nail 0.0915" dia.
x 1/8" with 19/61" head.
o.c. for walls up to 10'-0"* high. Space 3201 o.c. for walls up to 15'-0"*
5
For walls over 10'-0" a specia inspection is required b ang licensed structural
engineer to review and approve the vert. steel installaUn in the footings,
in the wall cavity and into beam.
= 2" x 4" non —bearing stud walls — see sections. Insulate
with R-11 batts at bathrooms t between A/C and
Non —A/C spaces
= 2" x 4" bearing stud walls — see sections. Insulate
with R-11 batts at bathrooms i between A/C and
Non —A/C spaces
= 211 x 4" bearing stud walls — see sections. Insulate
with R—M batts at bathrooms il. between A/C and
Non —A/C spaces
= 2" x 8" bearing stud walls — see sections. Insulate
with R—l'i'll batts at bathrooms t between A/C and
Non —A/C spaces
* top of wal'i hei4t is clear span of block to bottom of first structural beam
This applies to t e garage area onIg in this case.
2 1'- 2 ),, -,
SECOND FLOOR FLAN
2
� risers at
S treads at
CLOSET 174
AEOVE I/
STAIR DETAIL
2-1'-�" - - - - - — -oll I
SCALE 1/4" = l'—O"
3� H High
21t 61a. handrail
dttaChed tO Wall W1
min. 1 1/2" between
tair
.. OD
oo
T
T
Oc
1-
-s
oD
T
La
'q-
q-
Ln Lf
rZ
a M
C)
Z
—1
ILI
0
U
r
<
Q) Q) Lo 00
(L <
C14
(A C'4
U
o
iij X
u-
in
Sheet
2.
OF S.
Comm I
Scale: 1/2" '-01f
I