HomeMy WebLinkAboutPROJECT INFORMATIONFBC APPROVED PRODUCTS L �Yf` .
PRODUCT CATEGORY SUB CATEGORY MANUFACTURER APPROVAL
No. & DATE
STRUCTURAL COMPONENTS ROOF DECK UNION CORRUGATING COMPANY FL9555.2=R4
STRUCTURAL. COMPONENTS I STRUCTURALWALL
EXTERIOR DOORS SWINGING
EXTERIOR DOORS ROLL -UP
WINDOWS I SINGLE HUNG
NOTE:12 GA FRAMING
ROLL -UP DOOR
FRONT: ELEVATION .
SCALE: 1I8' =1'' '
26 Gauge MasterRib Panel 12/12/17
UNION CORRUGATING COMPANY
FL9555:2-R4
26 Gauge MasterRib Panel
12/12/17
ELIXIR DOOR AND METAL COMPANY
FL17996.5-R1
Series 407
01/29/18
ASTA INDUSTRIES INC.
FL8888.1-R5
Model 203
10/07/17.
MI WINDOWS AND DOORS
FL17499.1-R2
Model 185 SH
12/29/17
CONCF, LLD FASTENERS ORA TACHMENTS
ARE THE RESPONSIBIL" OF THE
CONTRACTOR OF RECORD
SWINGING DOOR
END ELEVATION. -
SCALE: 1/8' =1' -
GENERAL NOTES:
1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN
ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, FINISH FLOOR ELEVATIONS AND SLOPES, OR OTHER LOCAL ZONING
REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS.
2. THESE STRUCTURES ARE DESIGNED AS NON -HABITABLE UTILITYISTORAGE BUILDINGS (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND
APPLICABLE LIVE AND WIND LOADS: IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER. COMPONENTS NOT LISTED IN THE FBC
APPROVED PRODUCTS LIST (THIS SHEET), AND NOT PROVIDED AND INSTALLED BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE
AT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC.-, SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF
ADDITIONAL LOADS.
3. ALL COMPONENTS AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS.
4. ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL. ALL FASTENERS. SHALL BE GALVANIZED OR STAINLESS STEEL.
5. ALL FIELD FRAMING CONNECTIONS SHALL BE #12-14 x 1' SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER: ALL.SHOP FRAMING CONNECTIONS SHALL BE WELDED.
6. BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6' OF EVERY POST LOCATION, AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT,
7. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE'40.. CONCRETE SLAB FOUNDATIONS
SHALL BE REINFORCED WITH 6X6-W1 AXW1 .4 WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C11.16.
B. CONCRETE EXPANSION ANCHORS SHALL BE WEJ-IT ANKR-TITE MODELAT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT.
9. POST/RAFTER BRACING: BRACE ON EVERY POSTIRAFTERCONNECTION, EXCEPT FOR END WALLS AND GABLE ENDS.
10. SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED.WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FLORIDA BUILDING CODE, SIXTH
EDITION (2017) - RESIDENTIAL, AND SECTION 1816.1 OF THE FLORIDA BUILDING CODE, SIXTH EDITION (2017) -BUILDING. MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT.
BEARING PRESSURE OF 2,000 PSF IS ASSUMED.
If. 14 GA FRAMING: 2-1/2' x 2-112' TUBE STEEL ITS) WITH 2-1/4' x 2-1/4' TS NIPPLES.
12 GA FRAMING: 2-1/4' x 2-1/4' TS WITH 7 x 7 TS NIPPLES.
WINDOW
REAR ELEVATION
SCALE: 118' =1'
o2y2
ST. LUCI[E COT.JNT y BUTT. _ . iS
REVLEVVED FOR COMP �' E
REVIEMIED BY
DATE 0
PLANS ISM PERMIT St KEPT
OR NO INSPECTION �I-- _ Ii !1L
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY W171i ALL APPWCARI5 GGDES,
OCCUPANCY GROUP: U
CONSTRUCTION TYPE: II-B
RISK CATEGORY: I
BUILDING ENCLOSURE TYPE: ENCLOSED
WIND EXPOSURE CATEGORY: C
ULTIMATE WIND SPEED (MPH): 150
NOMINAL DESIGN WIND SPEED (MPH): 116
MEAN ROOF HEIGHT (FEET): 11.19
ROOF ANGLE (DEGREES): 14.0
DESIGN PRESSURES (PSF):
ROOF:
ZONE.1: +16.0 / -25.9
ZONE 2: +16:0 / -36:5
ZONE 3: +i6.0 /-57.6
DESIGN ROOF PRESSURES: +16.01.33.5
WALLS:
ZONE 4: +26.71-29.1
ZONE 5: +26.7 / -3Z5
DESIGN WALL PRESSURES: +26.71.30.4 .
SWINGING DOOR: +29.91-34.7
ROLL•UP DOOR +28.01-31.1
WINDOW: +3121.33.8
METAL FRAMING AND SIDING PREFABRICATED BY
CARPORTS ANYWHERE
P.O. BOX 776
STARKE,.FL 32091
THESE:ENGINEERING DRAWINGS ARE THE PROPERTY
OF BECHTOL ENGINEERING& TESTING; INC. AND
CARPORTS ANYWHERE, INC. THESE DRAWING MAY
NOT BE REPRODUCED WITHOUT THE WRITTEN
CONSENT OF BECHTOL ENGINEERING & TESTING, INC.,
AND CARPORTS ANYWHERE, INC.
THIS IS TO CERTIFY THAT THE CALCULATIONS AND SPECIFICATIONS
HEREIN HAVE -BEEN PREPARED BY THE .UNDERSIGNED
PROFESSIONAL ENGINEER, AND ARE IN ACCORDANCE WITH THE
REQUIREMENTS OF SECTION 1609 OF THE FLORIDA BUILDING CODE,
SIXTH EDITION (2017), THE PLANS ARE VALID UNTIL THE NEXT
REVISION OF THE FLORIDA BUILDING CODE.
BECHTOL ENGINEEI *' *G�61.
`T 605 WEST NEW YORKAV E'
0 •.•••... ,.
DELAND, FLORIDA 3272Q- .• Ucs/vS C
Certificate of AuthorizabomNo.' tC
o. 8 38
I JOB — r�
Thmas echtoI .E. -
Florida License
ZirT ATE OR ".�(/ku
PROPOSED UTILITY STRUCTURE �.
1206 COUNTRY GARDENS LANE
FORT PIERCE, FLORIDA
7/9/i8 . .
BECHTOL ENGINEER/NG °!"'�' : NM "�. NOTED
AND 7E8.WA Inc.
ca�uuNo xu, ENd+oNtlnrt4, AM UUMS Umm nimm. ' AAKB - '"°"a .G16002
.. umvhm TB - SHEET 1 OF 3
26 GA. GALVANIZED METAL WALL PANELS FASTENED
26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO POSTS WITH (2) #12-14 x 1' SDFs WITH CONTROL
TO RAFTERS WITH (2) #12-14 x 1' SDFs WITH CONTROL SEAL WASHER @ MAXIMUM 9' O.C. SPACING
SEAL WASHER @ MAXIMUM 9' O.C. SPACING
FRONT POST/RAFTER FRAMING PLAN
SCALE: 1/8' =1'
A
5'
END WALL POST/RAFTER FRAMING PLAN
SCALE: 1/8' = T
CONCRETE:
Concrete Shall Have a Minimum Specified Compressive Strength of 2500 PSI at28 Days
COVER OVER REINFORCING STEEL
For foundations, minimum concrete cover over reinforcing bars shall be:
3 inches in foundations where the concrete is cast against and permanently in contactw th the earth or exposed to the earth
or weather, and 1-1/2 inches elsewhere. Reinforcing bars embedded in grouted cells shall have a minimum clear distance of
1/4 inch for fine grout or 112 inch for coarse grout between reinforcing bars and any face ofa cell. Reinforcing bars used in
masonry walls shall have a masonry cover (including grout) of not less than 2 inches for masonry units with face exposed to
earth or weather 1-1/2 inches for masonry units not exposed to earth or weather.
REINFORCING STEEL:
The reinforcing steel shall be minimum Grade 40.
GALVANIZATION:
Metal accessories for use in exterior wall construction and not directly exposed to the weather shall be galvanized In
accordance with ASTM A 153, Class B-2. Metal plate connectors, screws, bolts and nails exposed directly to the weather
shall be stainless steel or hot dipped galvanized.
REINFORCEMENT MAY BE BENT IN THE SHOP OR THE FIELD PROVIDED:
1. All reinforcement is bent cold;
2. The diameter of the bend, measured on the inside of the bar, is not less than six -bar diameters; and
3. Reinforcement partially embedded in concrete shall not be field bent
EXCEPTION:
Where bending is necessary to align dowel bars with a vertical cell, bars partially embedded in concrete shall be
permitted to be bent at a slope of not more than 1 inch of horizontal displacement to 6 inches of vertical bar length.
12
Q 3
24' 16 GA U-CHANNEL BRACE
FASTENED TO RAFTER WITH
(2) #12-14 x 3/4' SDPs AT
a EACH END (4 PER BRACE)
(Typical, See Note 6, Sheet 1 of 3)
TYPICAL INTERIOR POST/RAFTER SECTION
SCALE: 1/8' =1'
FOUNDATION PLAN
SCALE: 1/8' = T
/U
REAR POST/RAFTER FRAMING PLAN
SCALE: 1/8' =1'
24'
IV MINIMUM
I I -
SECTION A -
SCALE: 1/8' =1'
BECHTOL ENG{Ih ��IIFSTiNG,�D C.
605 WEST NEW YO$F( E
DELAND, FLORIDA--02
Certificate of Auth 'a o Nb. No. 38538
homes BechP2' $TPFloridaLcen TE ONN-
�1111111110
PROPOSED UTILITY STRUCTURE
1206 COUNTRY GARDENS LANE
FORT PIERCE, FLORIDA
°" ' 7/9/18
BECHTOL ENGINEERING NM .•" NTS
AND 7EST7NGMMU�, /nG
CWMT04"GEID�ECOr A. DWMh6bffAL. AND W7seur5 MSnW ENWOUS '� MKB 'xu`"m G18002
°"'"'�io°`�°"°� � TB SHEET 2 OF 3
DRILL 5/8' HOLE THROUGH TI_ 2' WASHERS
r
BASE RAIL AND SECURE 1 1 - —'
T1'r_ .EyVE RAFTER
ANCHOR EYE WITH 1l2' DIAMETER TS CONTINUOUS
MINIMUM 6' LONG TS NIPPLE
THROUGH -BOLT BASE RAIL
RAFT 0 3116' —
WITH
MINIMUM 6' LONG TS NIPPLE
SECURE
SELF-DRILLING FASTENERS12-14x4•
e
48' 16 GA U-CHANNEL BRACE
SECURE WITH (4) #12-14x 314'
E
BRACE ANGLE SHALL BE MIN.45"
SELF -DRILLING FASTENERS
TS RAFTER POST CORNER
NIPPLEro ans (CORNER)
° TO MAX. 60° FROM HORIZONTAL
BASE RAIL
1-112' x 1-1/2' x 2' 16 GA CLIP
ANGLE, SECURE TO RAFTER
6'
POST AND BASE RAIL
.
TS RAFTER POST
° i WITH (4) #12-14 x 3/4' SDPs
P ° �
i I
12'
NIPPLE TO 3116'
BASE RAIL TS CONTINUOUS BASE RAIL
MINIMUM 6' LONG TS NIPPLE
°
SECURE RAFTER AND POST
TO NIPPLE WITH (4) #12-14 x 3l4'
MONOLITHIC CONC. FOOTING
SELF -DRILLING FASTENERS
° I
TS CONTINUOUS BASE RAIL
(2500 PSI MIN.) REINFORCED
WITH 2 #5's CONTINUOUS
TS RAFTER POST
EYE ANCHOR
5/8' ROD 48' LONG
WITH 6' HELLX
BOX EAVE
RAFTER POST/
RAFTER/CORNER POST CONNECTION DETAIL
BASE RAIL CONNECTION DETAIL
�� END POST/BASE RAIL CONNECTION DETAIL
CONCRETE MONO. SLAB BASE RAIL ANCHORAGE
Not To Scale
,t
1 Not To Scale
L Not To Scale
Not To Scale
TS TRUSSED RAFTER CHORD,
OR NON-STRUCTURAL HEADER
TS POST
(12 GA FOR ROLL -UP DOOR FRAME)
NIPPLE TO 3/16' 3' TS SPACER
DBL HEADER MAXIMUM T O.C.
TS RAFTER
2' x 2' x 2' 16 GA ANGLE CLIP
SECURE TO POST AND TOP OF
DBL TS STRUCTURAL HEADER
TS END POST OR DOOR/
HEADER, OR BOTTOM OF WINDOW
WITH 3' SPACERS
WINDOW FRAME POST 2•x2'x2' 16 GA ANGLE CLIP
RAIUGIRT WITH #12-14 x 3W SDF's
�e
(12 GA FOR ROLL -UP DOOR FRAME)
SECURE TO POST (EACH SIDE) AND
TS NON-STRUCTURAL HEADER RAFTER CHORD/RAIL WITH (4) #12-14x 3!4'
®®
(12 GA FOR ROLL -UP DOOR FRAME), SDF's, (2) ON BOTTOM AND (2) ON SIDE
BASE RAIL, OR WINDOW RAIL
2'x2'x2' 16 GA ANGLE CLIP
MINIMUM 6'LONG TS NIPPLE
NOTE: AT ROLL -UP DOOR OPENINGS,
TS NON-STRUCTURAL HEADER
SECURE TO POST AND
SECURE EACH WITH (4) #12-14 x 314'
POST SHOULD BE FLUSH WITH RAIL
(12 GA FOR ROLL -UP DOOR FRAME)
RAFTER WITH #12-14 x 31,V
SELF -DRILLING FASTENERS
END. CLIP POST TO RAIL ONLY ON
SDF's, (2) ON TOP AND
j ° I
SIDE OPPOSITE THE OPENING.
(2) ONSIDE
L J TS POST
OR
(12 GA FOR ROLL -UP DOOR FRAME)
TS END POST 2'x V 16 GA PLATE
TS WINDOW RAIL (OR GIRT
SECURE TO EACH SIDE OF
FOR VERTICAL SIDING OPTION)
POSTIRAFTER CONNECTION
-
WITRT9ffT2-T4 x 3A-SDFS,
-
(2) ON POST, (2) ON RAFTER
STRUCTURAL HEADER TO POST
POST TO NON-STRUCTURAL HEADER, BASE
NON-STRUCTURAL HEADER OR WINDOW
CONNECTION DETAIL - HDR BOTTOM
RAIL, OR WINDOW RAIL CONNECTION DETAIL
RAIL TO POST CONNECTION DETAIL
END POST/RAFTER CONNECTION DETAIL
o Not To Scale
5
6
7
Not To Scale
Not To Scale
Not To Scale
NIPPLETO 3/16'
DBL HEADER
TS RAFTER POST
BECHTOL EN /
GINEE0 1 i7�€$M19G,•IN
TxTx2' 16 GA ANGLE CLIP
605 WESTNEWFLORIDA K AV
605 WEST NEW PORK AV
SECURE TO POST AND
HEADER WITH (4) #12-14x 314'
Certificate o do a
3g53
TS POST
%` 0
(12 GA FOR ROLL -UP DOOR FRAME)
SDFs
MINIMUM 6' LONG TS NIPPLE
3' TS SPACER
—
SECURE EACH WITH (4) #12-14x 314'
SELF -DRILLING FASTENERS
MAXIMUM 2' O.C.
Thomas Be htol, P.E.
Florida License o. 38538 �'� •�. OF
3' TS SPACER
MAXIMUM T O.C.
• • • FLORA \V\\
DBL TS STRUCTURAL HEADER
2-1/4' FOR 16 GAUGE U-CHANNEL BRACE
FASTENED TO THE POST AND
/C)�
/ �\
'��, 1 ON PL
`ss
WITH 3' SPACERS WELDED BOTH SIDES
12 GA FRAMING
1 \
(12 GA FOR ROLL -UP DOOR FRAME)
2-1/2' FOR RAFTER, WITH (2) #12-14x 3W
/ )1 1 1 1 1 10
DBL TS STRUCTURAL HEADER
14 GA FRAMING SELF -DRILLING SCREWS AT
EACH END (4 PER BRACE)
WITH 3' SPACERS WELDED BOTH SIDES
(12 GA FOR ROLL -UP DOOR FRAME)
BRACE SECTION
PROPOSED UTILITY STRUCTURE
Not To Scale
1206 COUNTRY GARDENS LANE
STRUCTURAL HEADER TO POST
STRUCTURAL HEADER TO POST
NECTION DETAIL - HDR TOP
CTION DETAIL - HDR END
FORT PIERCE, FLORIDA
BECHTOL ENGINEERING
8
&NO Scale
�?T�
oar
AND TES77N4 6ir-
NM
NTS
om� MKB
mw.xa G18002
CD14SL NG emTc'Mru. o+vwoA(DUu, AW WTBIALS hsMW DOMM
APiO @ TB
SHEET 3 OF 3
` vl'd �tr�"°'0000Q1°'