HomeMy WebLinkAboutLETTER ROOF SPECIFICATIONSA,rchitectonic Inc May 2, 2018 -91 Saint Lucie County Building Department Attn: Roof Permit Plan Review 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Roofing specification preps located at 230 Olson Avem alYj9u COU* <Ter FILE'. COPr i for the.St. Lucie County Building Dept. for the structure St. Lucie County, FL Manufacturer: Tri-Built hoofing Products Profiles: Tri —Built �odified, FL# 16027-112 Code: FBC 2017) Section R 905.10 Wind Speed: 165 MPH, Ultimate Design Wind Speeds Exposure: C Mean Roof Height: 30' Maximum Pitch: % /12 Required Design Pressure: Zone1: -3�3 Zone 2: -52.8 Zone3:-73.45 Maximum Uplift Pressure: -60 Zone & Zone 2, -96.9 Zone 3 Base: Certain Teed Glasbase with 32 ga. 1-5/8" diameter Tin Caps w/ 11 ga. Annular ring shank nails @ 8" o.c. in 4 inch lap and 8" o.c. in three equally spaced, staggered center rows Zone 1 & 2, Zone 3 fasteners shall be spaced @ 6" o.c. in 4 inch lap & 6" o.c. in three equally spaced staggered center rows Ply Sheet: (Optional) One or more SBS-SA or APP-TA Cap: SBS-SA, APP-SA, SBS-TA OR APP-TA The above approved, as per Florida Building and the Manufacturer's recommendations. Mich Arch! e Compliance acceptances, 2017 Florida Building Code, 806 Delaware Avenue Tel; 772 46017751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 46014244 FL Reg #AA26003348 1 of 1