HomeMy WebLinkAboutLETTER-ROOF SPECIFICATIONS1
Architectonic Inc
April 8, 2017
Saint Lucie County Building Department
Attn: Roof Permit Plan Review
2300 Virginia Avenue
Ft. Pierce, FL 34982
BY
%[l. cle , ad'v
Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure
located at 3808 Avenue I. St. Lucie County
Manufacturer:
Profiles:
Code:
Wind Speed:
Exposure:
Mean Roof Height:
Pitch:
Required Design Pressure:
Maximum Uplift Pressure:
Roof Decking:
Base:
Ply Sheet:
Cap:
Tri-Built Roofing Products
Tri —Built Modified, FL# 16027.111
FBC 2017; Section R 905.10
160 MPH; Ultimate Design Wind Speeds
B
30' Maximum
/12
Zone1: -26.0 Zone 2: -41.0 Zone3: -57.0
-60
Min 19/32" plywood at max, 24" spans attached 6" o.c., 8d x2" ring
shank nails
32 ga.1-5/8 inch diameter tin caps with 11 ga. annular ring shank nails.
8-inch o.c. in 4-inch lap and 8-inch o.c. in three, equally spaced,
staggered center rows.
(Optional) One or more SBS-SA or APP-TA
SBS -SA , APP-SA, SBS-TA OR APP-TA
The above approved, as per Florida Building C
and the Manufacturer's recommendations.
Re Iiit$
HA j
q.kl Seal 6898jtonicI •••'R
pde Compliance acceptances, 2017 Florida Building Code,
I SOS - 0�7
y�rrn, FILE COPS
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1