Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION
Right -Suite A/C ONE DRAWDY OFFICE PARK PHASE III MIDWAY RD, FT. PIERCE, FL stw e County 1. DESIGN CONDITIONS at Jul 1500 Inside: 75 OF Outside: 90 RH: 50 % Moisture: 61.5 2. SOLAR RADIATION THROUGH GLASS 3. TRANSMISSION GAINS Sensible Walls: 109 Glass: 94 Doors: 81' Partitions: Floors: Roofs/Ceilings: 540 Return Air Ceiling: 4. INTERNAL HEAT GAIN Sensibl( Occupants: 224 Lights: 1087 Motors: Appliances: 323 5. INFILTRATION: Outside air cfm: 6. SUBTOTAL: Space load 7. SUPPLY DUCT 8. SUBTOTAL: Bldg comp's and suppl) Actual cfm: 1400 at Supp 9. VENTILATION: Make-up air cfn 10. RETURN AIR LOAD: Lighting 8r roo 11. RETURN DUCT 12. TOTAL LOADS ON EQUIPMENT HEATI Summary Job: DEC 22, 2006 Peak load at Jul 1500 - TD: 15 OF r/lb Mult: 1.0 Ins.wb 63 OF Sensible Latent 1148 - 8253 - Latent 16353 1783 1783 - - ! 0 - - 30 495 1274 26248 3058 0 - duct 26734 - TD: 20 - - 223 3678 9477 (net) 00 _ 30412 12535 G LOAD 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 OF Outside: 42 OF TD: 28 OF 14. TRANSMISSION LOSSES 10275 Walls: 2087 - Glass: 1922 - Doors: 1564 - Partitions: 0 - Floors: 2427 - Roofs/Ceilings: 227$ - Return Air Roof: 0 - 15. INFILTRATION: Outside air cfm: 60 1846 16. SUBTOTAL: Building components 12122 17. SUPPLY DUCT: 0 I& VENTILATION: Make-up air cf : 223 6866 19. HUMIDIFICATION 1871 20. RETURN DUCT 0 21. TOTAL HEATING LOAD ON EQUIPM T 20858 WPIG,II'7tSOfC Right-SuNeCommercial 5.8.13RSC50847 2006-Deo-2711:30:04 CMRAWDY BROS PHASE 11.rsc Page 1 Y 4 Right -Suite Comm rcial Short Form ��•�, A/C ONE Job: DEC 22, 2006 ProjectIn-formation For: DRAWDY OFFICE PARK PHASE III MIDWAY RD, FT. PIERCE, FL Htg Clg Outside db (OF) 42 90 Outside RH (%) - 59 Outside wb (OF) - 78 Daily range (OF) - 15 Moisture diff. (gr/lb) - 61 Heating Equipment Make TRANE Model 2TEC3F42A Type ELECTRIC Efficiency / HSPF 100.0 Heating Input 34000 MBtuh Heating Output 0.0 MBtuh Humidifier 0.0 gpd Leaving Air Temp 70.0 OF Actual Heating Fan 0 cfm Equipment Location System Type Fan Motor Heat Type Fan & Motor Combined Efficii Static Pressure Across Fan Htg Clg Inside db . (OF) 70 75 Inside RH (%) - 50 Inside wb (OF) - 63 Design TD (OF) 28 15 Cooling Equipment Make TRANE Model 2TB3042A Type STRAIGHT COOL COP / EER / SEER 13.0 Sensible Cooling 31500 MBtuh Latent Cooling 9000.0 MBtuh Total Cooling 40500 MBtuh Leaving Air Temp 55.0 OF Actual Cooling Fan 1400 cfm A/C ONE VAV DRAWTHRU 10.0 % 0.1 in H2O NAME Area Heat Sensible Latent Htg Clg Time ft2 Loss Gain Gain cfm cfm UNIT 1 1298 18260 28815 10358 0 1360 Jul 1500 BATH 1 56 2599 1596 2176 0 40 Jul1500 A/C ONE 1354 20858 30412 1 12535 1 0 1400 1 Jul1500 Right -Suite Commercial Load Calculation UNIT 1 Job: DEC 22, 2006 Project Inf• • For: DRAWDY OFFICE PARK PHASE III MIDWAY RD, FT. PIERCE, FL Zonei_ UNIT 1 LWH: 1298 x 1.0 x 9.0 1. DESIGN CONDITIONS - COOLING (Jul1 1500 ) Dry Blb H Moisture Range Wet Blb Outdoor Conditions —> 90 59 15 78 Indoor Conditions —> 75 50 63 TOD Correction —> 0 Difference 15 I 61.5 Mult = 1.0 ] — 2. GLAZING SOLAR HEAT GAIN ( Lat = 27.45 ON Const Wt = M ) Type Orien Area Tilt ShdF IntShd SCMult SC Sens/A Sens GLAZ 1 E 62 90 -- N 1.00 0.30 18.4 1148 3. TRANSMISSION GAINS Type Orlen GrArea NtArea Uval Grp CLTD Shad Clr Sens GLAZ 1 E 62 62 1.040 14.5 N - 941 WALL 1 E 297 193 0.089 B 24.5 N D 420 WALL 1 S 369 369 0.089 B 9.8 N D 322 WALL 1 W 225 204 0.089 B 14.5 N D 263 DOOR 7 e 21 21 1.100 14.5 - - 335 DOOR 8 e 21 21 1.100 14.5 - - 335 DOOR 9 w 21 21 0.460 14.5 - - 140 FLOR 1 - 99 99 0.810 0.0 - - 0 ROOF 1 - 1298 1298 0.060 R-4 66.5 - D 5180 4. INTERNAL HEAT GAIN Sens Latent PEOPLE Activity Total Sensible Latent Schedule ftz/prsn # people Btuh/prsn Btuh/prsn Office 150 0 9 250 200 2164 1731 8to6 0 0 0 0 0 0 0 wrjghtsoft Right -Suite Commercial 5.8.13 RSC50847 2006Deo-2714:21:00 C:IDRAWDY BROS PHASE 11.= Page 1 _ LIGHTS Type Total - Schedule W/ftz W W Fluorescent 2.00 0 2597 . 8to6 • Fluorescent 0.00 0 0 ' Fluorescent . 0.00 0 0 • Fluorescent 0.00 0 0 PLUG LOADS / APPLIANCES . Application Usage Total Schedule Plug load W/ftz W 8to6 0.70 0 1.00 909 #/ftz # 0.000 0.00 1.00 0 #/ftz # 0.000 0.00 1.00 0 #/ftz # 0.000 0.00 1.00 0 #/ftz # 0.000 0.00 1.00 0 #/ftz # 0.000 0.00 1.00 0 MOTORS Power (hp) Load Total Schedule #/ftz # factor 0.00 0.0 0 1.00 0 0.00 0.0 0 1.00 0 0.00 0.0 0 1.00 0 Factor Space Btuh/W fract 4.10 1.0 10646 4.10 1.0 0 4.10 1.0 0 4.10 1.0 0 Sensible Latent Btuh Btuh 3 0 3101 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Sensible Btuh 0 0 0 0 0 0 5. INFILTRATION Sens Latent 30 cfm x db Temp Diff 15.0 x 1.10 495 -> x Moist. Diff 61.5 x 0.69 1274 6. SUBTOTAL COOLING LOAD FOR SPACE 25490 10358 7. SUPPLY DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensible Gain 0 8. COOLING FAN SIZING Sum of Duct Gain (7), Line (6) & Drawthru Fan = 25961 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 26961) / ( 1.10 x 20.0 ) = 1181 Actual Cooling Fan I > = 1360 9. VENTILATION 173 cfm -> x db Temp Diff -� x Moist. Diff 10. RETURN AIR LOAD FROM LIGHTING AND ROOF Lights Total power (W) RA Roof Load from Line 3 I (+) RA Ceiling Load Credit from Line 3 (-) 15.0 x 1.10 2854 61.5 x 0.69 7353 36893P 10646 0 wrvghtsoft Right -Suite Commercial 5.8.13 RSC50847 2006Dec-27 14:21:00 C:\DRAWDY BROS PHASE 11.rsc Page 2 11. RETURN DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensible Gain 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) I • SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (inside DB - Outside DB) 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval GLAZ 1 E 62 62 1.100 WALL 1 E 297 193 0.089 WALL 1 S 369 369 0.089 WALL 1 W 225 204 0.089 DOOR 7 e 21 21 1.100 DOOR 8 e 21 21 1.100 DOOR 9 w 21 21 0.460 FLOR 1 - 99 99 0.810 ROOF 1 - 1298 1298 0.060 0 28815 10358 70 - 42) = 28 Mult = 1.0 HTD Loss 28.0 1922 28.0 480 28.0 920 28.0 508 28.0 647 28.0 647 28.0 270 28.0 2245 28.0 2181 15. INFILTRATION I Loss 60 cfm x db Temp Diff 28.0 x 1.10 1846 16. SUBTOTAL HEATING LOAD FOR SPACE I 11667 17. SUPPLY DUCT HEAT LOSS Loss factor 0.00 x Line 16 Loss 0 18. VENTILATION 173 cfm x db Temp Diff 28.0 1.10 5327 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 233 cfm x 1.48 g/100cfm/d I = 3.5 gpd 1266 20. RETURN DUCT HEAT LOSS Loss factor 0.00 x Line 16 Loss 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) s wmghtsoft Right-Sufte Commercial 5.8.13 RSC50847 C:IDRAWDY BROS PHASE 11.rsc E 18260 2006-Dec-27 14:21:00 Page 3 Right -Suite Commercial Load Calculation BATH 1 Job: DEC 22, 2006 For: DRAWDY OFFICE PARK PHASE III MIDWAY RD, FT. PIERCE, FL _BATH 1________________. LWH: 7.0 x 8.0 x 9.0 1. DESIGN CONDITIONS - COOLING (Jul 1500 ) Dry Bib R Moisture Range Wet Bib Outdoor Conditions 90 59 15 78 Indoor Conditions 75 50 63 TOD Correction —> 0 Difference 15 I 61.5 II _ Mult - 1.0 ] — 2. GLAZING SOLAR HEAT GAIN ( Lat = 27 45 °N Const Wt = M ) Type Orien Area Tilt ShdF IntShd SCMult Sc Sens/A Sens n/a 0 n/a 0 0 10.00 0.00 0.0 0 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens WALL 1 W 72 72 0.089 B 14.5 N D 93 FLOR 1 - 8 8 0.810 0.0 - - 0 ROOF 1 - 56 56 0.060 R4 66.5 - D 223 4. INTERNAL HEAT GAIN PEOPLE Sens Latent Activity Total Sensible Latent Schedule ftz/prsn # people Btuh/prsn Btuh/prsn Restroom 150 0 0 210 140 78 8to6 0 0 0 0 0 0 wrightSoft Right -Suite Commercial 5.8.13 RSC50847 C:MRAWDY BROS PHASE 1 Use 52 0 2006-Dec-2714:21:00 Page 1 _ LIGHTS Type Total Factor Space ' Schedule W/ft2 W W Btuh/W fract _ Fluorescent 1.00 0 56 4.10 1.0 230 8to6 ' Fluorescent 0.00 0 0 4.10 1.0 0 " Fluorescent 0.00 0 0 4.10 1.0 0 • Fluorescent 0.00 0 0 4.10 1.0 0 PLUG LOADS / APPLIANCES Application Usage Total Sensible Latent Schedule Btuh Btuh Plug load W/ftz W 8to6 0.70 0 1.00 39 3 0 134 0 #/fta # 0.000 0.00 1.00 0 0 0 0 0 #/ftz # 0.000 0.00 1.00 0 0 0 0 0 #/ftz # 0.000 0.00 1.00 0 0 0 0 0 #/ftz # 0.000 0.00 1.00 0 0 0 0 0 #/ftz # 0.000 0.00 1.00 0 0 0 0 0 MOTORS Power (hp) Load Total Sensible Schedule #/ftz # factor Btuh 0.00 0.0 0 1.00 0 0 0 0.00 0.0 0 1.00 0 0 0 0.00 0.0 0 1.00 0 0 0 5. INFILTRATION Sens Latent 0 cfm > x db Temp Diff 15.0 x 1.10 0 > x Moist. Diff 61.5 x 0.69 0 6. SUBTOTAL COOLING LOAD FOR SPACE I 758 2176 7. SUPPLY DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensible Gain 0 8. COOLING FAN SIZING Sum of Duct Gain (7), Line (6) & Drawly ru Fan = 772 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 772) / (1.10 x 20.0 ) = 35 Actual Cooling Fan > = 40 9. VENTILATION - 50 cfm -> x db Temp Diff 15.0 x 1.10 824 - ------ > x Moist. Diff 61.5 x 0.69 2124 - 10. RETURN AIR LOAD FROM LIGHTING AND ROOF Lights Total power (W) 0 230 RA Roof Load from Line 3 (+) 0 RA Ceiling Load Credit from Line 3 (-) 0 wrightsoft Right -Suite Commercial 5.8.13 RSC50847 2006-Dec-27 14:21:00 CMRAWDY BROS PHASE 1 Use Page 2 11. RETURN DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensiple Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 1596 2176 ' SPACE HEATING LOAD CALCULATION ' 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 Mult = 1.0 j — 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval WALL 1 W 72 72 0.089 HTD 28.0 Loss 179 FLOR 1 - 8 8 0.810 28.0 181 ROOF 1 - 56 56 0.060 28.0 94 15. INFILTRATION I Loss 0 cfm x db Temp Diff 28.0 1.10 0 16. SUBTOTAL HEATING LOAD FOR SPACE I 455 17. SUPPLY DUCT HEAT LOSS Loss factor 0.00 x Line 16 Loss 0 18. VENTILATION 50 cfm x db Temp Diff 28.0 x 1.10 1539 19. HUMIDIFICATION Inside RH desired 40.0 (Max = 32�.0 for 1 pane ) # of Glazing panes 0.0 (Max = 52.0 for 2 pane ) 50 cfm x 3.20 g/100cfm/d I= 1.6 gpd 605 20. RETURN DUCT HEAT LOSS Loss factor 0.00 x Line 16 Loss 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) wnghtsoft Right-Suke Commercial 5.8.13 RSC50847 CA)RAWDY BROS PHASE 11.rsc 2599 2006-Deo-2714:21:00 Page 3 Right -Suite A/C TWO For: DRAWDY OFFICE PARK PHASE III MIDWAY RD, FT. PIERCE, FL I- r Zone: ^ A%C TWO_____COOLING_L 1. DESIGN CONDITIONS at Jul 1500 Inside: 75 OF Outside: 90 OF RH: 50 % Moisture: 61.5 gr/lb 2. SOLAR RADIATION THROUGH GLASS 3. TRANSMISSION GAINS Sensible Walls: 700 Glass: 1255 Doors: 615 Partitions: 0 Floors: 0 Roofs/Ceilings: 5240 Return Air Ceiling: 0 4. INTERNAL HEAT GAIN Sensible Occupants: 2174 Lights: 10540 Motors: 0 Appliances: 3137 5. INFILTRATION: Outside air cfm: 6. SUBTOTAL: Space load 7. SUPPLY DUCT 8. SUBTOTAL: Bldg comp's and supply duct Actual cfm: 1400 at Supply TD: 9. VENTILATION: Make-up air cfm: 10. RETURN AIR LOAD: Lighting & roof (net) 11. RETURN DUCT 12. TOTAL LOADS ON EQUIPMENT HEATING U 13. DESIGN CONDITIONS Inside: 70 OF Outside: 42 OF 14. TRANSMISSION LOSSES Walls: 1071 Glass: 2563 Doors: 1188 Partitions: 0 Floors: 1452 Roofs/Ceilings: 2206 Return Air Roof: 0 15. INFILTRATION: Outside air cfm: 16. SUBTOTAL: Building components 17. SUPPLY DUCT: 18. VENTILATION: Make-up air cfm: 19. HUMIDIFICATION 20. RETURN DUCT 21. TOTAL HEATING LOAD ON EQUIPMENT wrjghtsoft Right -Suite Commercial 6.8.13 RSC50847 CMRAWDY BROS PHASE 11,rsc I Load Summary Job: DEC 22, 2006 OAD---- -`- ----- -- -- -- ---- --, Peak load at Jul 1500 TD: 15 OF Mult: 1.0 Ins.wb 63 OF Sensible Latent 1531 - 7809 - Latent 15850 1729 1729 - - 0 - - 30 495 1274 25686 3003 0 - 26160 - 20 - - 218 3588 9245 0 - 0 - 29748 12248 Mult: 1.0 TD: 28 OF 8479 60 1846 10326 0 218 6697 I 1841 0 18864 2006-Deo-27 11:30:04 Page 2 Right -Suite Commercial Short Form A/C TWO For. DRAWDY OFFICE PARK PHASE III MIDWAY RD, FT. PIERCE, FL Htg Clg Outside db (OF) 42 90 Outside RH (%) - 59 Outside wb (OF) - 78 Daily range (OF) - 15 Moisture dill. (gr/lb) - 61 Heating Equipment Make TRANE Model 2T3C3F42A Type ELECTRIC Efficiency / HSPF 100.0 Heating Input 34000 MBtuh Heating Output 0.0 MBtuh Humidifier 0.0 gpd Leaving Air Temp 70.0 OF Actual Heating Fan 0 cfm Equipment Location •System Type Fan Motor Heat Type Fan & Motor Combined Efficiency Static Pressure Across Fan Job: DEC 22, 2006 Htg Clg Inside db (OF) 70 75 Inside RH (%) - 50 Inside wb (OF) - 63 Design TD (OF) 28 15 Cooling Equipment Make TRANE Model 2TTB3042A100 Type STRAIGHT COOL COP / EER / SEER 13.0 Sensible Cooling 31400 MBtuh Latent Cooling 9100.0 MBtuh Total Cooling 40500 MBtuh OF Leaving Air Temp 55.0 Actual Cooling Fan 1400 cfm A/C TWO VAV DRAWTHRU 10.0 % 0.1 in H2O NAME Area Heat Sensible) Latent Htg Clg Time ft2 Loss Gain Gain Cfm cfm UNIT 2 1257 16266 28152 10072 0 1359 Jul1500 BATH 2 56 2599 1596 2176 0 41 Jul 1500 A/C TWO 1313 18864 29748 12248 0 1400 1 Jul1500 Right -Suite Commercial Load Calculation UNIT 2 Job: DEC 22, 2006 For: DRAWDY OFFICE PARK PHASE III MIDWAY RD, FT. PIERCE, FL Zone: UNIT 2 LWH: 1257 x 1.0 x 9.0 I 1. DESIGN CONDITIONS - COOLING ( Jul 1500 ) Dry Bib RH Moisture Range Wet Bib Outdoor Conditions —> . 90 59 15. 78 Indoor Conditions 75 50 .63 TOD Correction —> 0 Difference 15 I 61.5 i Mult = 1.0 ] — 2. GLAZING SOLAR HEAT GAIN ( Lat = 27.45I °N Const Wt = M ) Type Orien Area Tilt ShdF IntShd SCMult SC Sens/A Sens GLAZ 1 E 83 90 --- N 1.00 0.30 18.4 1531 3. TRANSMISSION GAINS I Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens GLAZ 1 E 83 83 1.040 14.5 N - 1255 WALL 1 E 288 163 0.089 B 24.5 N D 355 WALL 1 W 216 195 0.089 B 14.5 N D 252 DOOR 4 e 21 21 0.460 14.5 - - 140 DOOR 5 e 21 21 1.100 14.5 - - 335 DOOR 6 w 21 21 0.460 14.5 - - 140 FLOR 1 - 56 56 0.810 0.0 - - 0 ROOF 1 - 1257 1257 0.060 R-4 66.5 - D 5017 4. INTERNAL HEAT GAIN. Sens Latent PEOPLE - Activity Total Sensible Latent Schedule_ ft2/prsn # people Btuh/prsn Btuh/prsn - Office 150 0 8 250 200 2096 1676 - 8to6 0 0 0 0 0 0 0 W rjghtSOft Right -Suite Commercial 5.8.13 RSC50847 2006-Dec-2714:21:00 C:IDRAWDY BROS PHASE 1 Use Page 1 _ LIGHTS Type Total Factor Space - Schedule W/ft2 W W Btuh/W fract Fluorescent 2.00 0 2515 4.10 1.0 10310 ' 8to6 • Fluorescent 0.00 0 0 4.10 1.0 0 • Fluorescent 0.00 0 0 4.10 1.0 0 • Fluorescent 0.00 0 0 4.10 1.0 0 PLUG LOADS / APPLIANCES Application Usage Total Sensible Latent Schedule Btuh Btuh Plug load W/ftz W 8to6 0.70 0 1.00 880 3 0 3003 0 #/ft2 # 0.000 0.00 1.00 0 0 0 0 0 #/ft2 # 0.000 0.00 1.00 0 0 0 0 0 #/ft2 # 0.000 0.00 1.00 0 0 0 0 0 #/ft2 # 0.000 0.00 1.00 0 0 0 0 0 #/ft2 # 0.000 0.00 1.00 0 0 0 0 0 MOTORS Power (hp) Load To al Sensible Schedule #/ft2 # factor I Btuh 0.00 0.0 0 1.00 I0 0 0 0.00 0.0 0 1.00 0 0 0 0.00 0.0 0 1.00 I Q 0 0 5. INFILTRATION Sens Latent 30 cfm -> x db Temp Diff 15.0 x 1.10 495 �> x Moist. Diff 61.5 x 0.69 1274 6. SUBTOTAL COOLING LOAD FOR SPACE I 24927 10072 7. SUPPLY DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensible Gain 0 8. COOLING FAN SIZING Sum of Duct Gain (7), Line (6) & Drawthru Fan = 25388 (L 8 Sens ) / (Xfer x S pply TD ) = cfm Est Cooling cfm = ( 25388) / ( 1.10 x I 20.0 ) = 1165 Actual Cooling Fan 9. VENTILATION 168 cfm -> x db Temp Diff 15.0 x 1.10 2764 > x Moist. Diff 61.5 x 0.69 7121 i - 10. RETURN AIR LOAD FROM LIGHTING AND ROOF Lights Total power ( W) 36893P 10310 RA Roof Load from Line 3 (+) 0 RA Ceiling Load Credit from Line 3 (-) 0 wrightsoft RightSufte Commercial 5.8.13 RSC50847 2006-Dec-2714:21:00 CADRAWDY BROS PHASE 1 Use Page 2 11. RETURN DUCT HEAT GAIN I Gain factor 0.00 x Line 6 Sensiple Gain 12. TOTAL COOLING LOADS ON EQUIPMENT (Btub) SPACE HEATING LO�D CALCULATION -• 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval GLAZ 1 E 83 83 1.100 WALL 1 E 288 163 0.089 WALL 1 W 216 195 0.089 DOOR 4 e 21 21 0.460 DOOR 5 e 21 21 1.100 DOOR 6 w 21 21 0.460 FLOR 1 - 56 56 0.810 ROOF 1 - 1257 1257 0.060 28152 10072 70 - 42) = 28 Muit = 1.0 HTD Loss 28.0 2563 28.0 406 28.0 486 28.0 270 28.0 647 28.0 270 28.0 1270 28.0 2112 15. INFII.TRATION LOSS 60 cfm x db Temp Diff 28.0 x 1.10 1846 16. SUBTOTAL HEATING LOAD FOR SPACE I 9871 17. SUPPLY DUCT HEAT LOSS Loss factor 0.00 x Line 16 Loss 0 18. VENTILATION 168 cfm x db Temp Diff 28.0 x . 00 5159 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes : 1.0 (Max = 52.0 for 2 pane ) 228 cfm x 1.48 g/100cfm/d = 3.4 gpd 1236 20. RETURN DUCT HEAT LOSS Loss factor 0.00 x Line 16 Loss • f.1• 1 V lAL 11LAau�V LVAL V1. ..•ova i.aa..a. a �u a..u� wrjghtsoft Right -Suite Commercial 5.8.13 RSC50847 CMRAWDY BROS PHASE 11.rsc 0 16266 2006-Deo-2714:21:00 Page 3 Right -Suite Commercial Load Calculation BATH 2 For: DRAWDY OFFICE PARK PHASE III MIDWAY RD, FT. PIERCE, FL Zone: BATH 2 LWH: 7.0 x 8.0 x 9.0 1. DESIGN CONDITIONS - COOLING Dry Bib Outdoor Conditions —> 90 Indoor Conditions 75 TOD Correction —> 0 Difference 15 Job: DEC 22, 2006 ( Jul 1500 ) RH Moisture Range Wet Bib 59 15 78 50 63 61.5 Mult = 1.0 ] — 2. GLAZING SOLAR HEAT GAIN ( Lat = 27.45 -N Const Wt = M ) Type Orien Area Tilt ShdF IntShd SCMult SC Sens/A Sens n/a 0 n/a 0 0 0.00 0.00 0.0 0 3. TRANSMISSION GAINS I Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens WALL 1 W 72 72 0.089 B 14.5 N D 93 FLOR 1 - 8 8 0.810 0.0 - - 0 ROOF 1 - 56 56 0.060 R-4 66.5 - D 223 4. INTERNAL HEAT GAIN PEOPLE Activity Total Schedule ft/prsn # people Restroom 150 0 0 8to6 0 0 0 wrjghtsoft Right -Suite Commercial 5.8.13 RSC50847 C:IDRAWDY BROS PHASE 11.rsc Sens Latent Sensible Latent Btuh/prsn Btuh/prsn 210 140 78 52 0 0 0 0 2006-Dec-2714:21:00 Page 1 - LIGHTS Type Total Factor Space Schedule W/ft2 W W Btuh/W fract _ _ Fluorescent 1.00 0 56 4.10 1.0 230 • 8to6 Fluorescent 0.00 0 0 4.10 1.0 0 Fluorescent 0.00 0 0 4.10 1.0 0 •• Fluorescent 0.00 0 0 4.10 1.0 0 PLUG LOADS / APPLIANCES Application Usage otal Sensible Latent ' Schedule Btuh Btuh Plug load W/ft2 W 8to6 0.70 0 1.00 39 3 0 134 0 #/ft2 # 0.000 0.00 1.00 0 0 0 0 0 #/ft2 # 0.000 0.00 1.00 0 0 0 0 0 #/ft2 # 0.000 0.00 1.00 0 0 0 0 0 #/ft2 # 0.000 0.00 1.00 0 0 0 0 0 #/ft2 # 0.000 0.00 1.00 0 0 0 0 0 MOTORS Power (hp) Load To al Sensible Schedule #/ft2 # factor . Btuh 0.00 , 0.0 0 1.00 i 0 0 0.00 0.0 0 1.00 i 0 0 0.00 0.0 0 1.00 Q 0 0 5. INFILTRATION Sens Latent 0 cfm > x db Temp Diff 15.0 x 1.10 0 > x Moist. Diff 61.5 x 0.69 0 6. SUBTOTAL COOLING LOAD FOR SPACE I 758 2176 7. SUPPLY DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensible Gai 0 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 772 • (L 8 Sens ) / (Xfer x S pply TD ) = cfm Est Cooling cfm = ( 772) / ( 1.10 x I 20.0 ) = 35 Actual Cooling Fan I > = 41 9. VENTILATION 50 cfm > x db Temp Diff > x Moist. Diff 10. RETURN AIR LOAD FROM LIGHTING AND ROOF Lights Total power (W) RA Roof Load from Line 3 (+) RA Ceiling Load Credit from Line 3 (-) wrightsoft Right -Suite Commercial 5.8.13 RSC50847 CMRAWDY BROS PHASE 111.= 15.0 x 1.10 61.5 x 0.69 824 2124 0 230 0 0 2006-Dec-2714:21:00 Page 2 .11. RETURN DUCT HEAT GAIN - Gain factor 0.00 x Line 6 Sensible Gain 0 ' - 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) I 1596 2176 SPACE HEATING LOAD CALCULATION i - 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 ' Mult = 1.0 ] — 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss WALL 1 W 72 72 0.089 28.0 179 FLOR 1 - 8 8 0.810 28.0 181 ROOF 1 - 56 56 0.060 28.0 94 15. INFILTRATION Loss 0 cfm x db Temp Diff 28.0 x 1.10 0 16. SUBTOTAL HEATING LOAD FOR SPACE I 455 17. SUPPLY DUCT HEAT LOSS Loss factor 0.00 x Line 16 Loss - 0 18. VENTILATION 50 cfm x db Temp Diff 28.0 x 1.10 1539 19. HUMIDIFICATION Inside RH desired 40.0 (Max = 32.0 for 1 pane ) # of Glazing panes 0.0 (Max = 52.0 for 2 pane ) 50 cfm x 3.20 g/100cfm/d = 1.6 gpd . 605 20. RETURN DUCT HEAT LOSS Loss factor 0.00 x Line 16 Loss 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 2599 wrightsoft Right -Suite Commercial 5.8.13 RSC50847 2006-Dee-27 14:21:00 C:IDRAWDY BROS PHASE 11.rsc I Page 3 Im Right-Suite Commercial Load Summary A/C THREE For: DRAWDY OFFICE PARK PHASE III MIDWAY RD, FT. PIERCE, FL Job: DEC 22, 2006 COOLING LOAD 1. DESIGN CONDITIONS at Jul 1500 Peak load at Jul 1500 Inside: 75 OF Outside: 90 OF TD: 15 OF ' RH: 50 % Moisture: 61.5 gr/lb Mult: 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 1148 - 3. TRANSMISSION GAINS Sensible 8660 - Walls: 1183 - - Glass: 941 - - Doors: 810 - - Partitions: 0 - - Floors: 0 - - Roofs/Ceilings: 5726 - - Retum Air Ceiling: 0 - - 4. INTERNAL HEAT GAIN Sensible Latent 17341 1891 Occupants: 2377 1891 - - Lights: 11537 - - - Motors: 0 - - - Appliances: 3427 0 - - 5. INFILTRATION: Outside air cfm: 30 495 1274 6. SUBTOTAL: Space load 27644 3165 7. SUPPLY DUCT 0 - 8. SUBTOTAL: Bldg comp's and supply duct 28155 - Actual cfm: 1400 at Supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 234 3855 9934 10. RETURN AIR LOAD: Lighting & roof (net) 0 - 11. RETURN DUCT 0 - 12. TOTAL LOADS ON EQUIPMENT 32011 13099 - - - --- -- - - - - - -- - -- - -- HEATING LOAD I~ 13. DESIGN CONDITIONS Mult: Inside: 70 OF Outside: 42 OF TD: 14. TRANSMISSION LOSSES ` Walls: 2177 Glass: 1922 Doors: 1564 - Partitions: 0 Floors: 2517 _ Roofs/Ceilings: 2411 - Return Air Roof: 0 15. INFILTRATION: Outside air cfm: 60 - 16. SUBTOTAL: Building components 17. SUPPLY DUCT: 18. VENTILATION: Make-up air cfm: 23 19. HUMIDIFICATION I 20. RETURN DUCT 21. TOTAL HEATING LOAD ON EQUIPMENT 1.0 28 OF 10591 1846 12438 0 4 7197 1929 0 21563 wrigh>ttsoft Right -Suite Commercial 6.8.13 RSC50847 I 2006-Dec-27 11:30:04 C:IDRAWDY BROS PHASE 11.rsc Page 3 Right-Suite Com A/C THREE For: DRAWDY OFFICE PARK PHASE III MIDWAY RD, FT. PIERCE, FL Htg Clg I Outside db (OF) 42 90 Outside RH (%) - 59 Outside wb (OF) - 78 Daily range (OF) - 15 Moisture diff. (gr/lb) - 61 Heating Equipment Make TRANE Model 2TEC3F42A100 Type ELECTRIC Efficiency / HSPF 100.0 Heating Input 34000 MBtuh Heating Output 0.0 MBtuh Humidifier 0.0 gpd Leaving Air Temp 70.0 OF Actual Heating Fan 1400 cfm Equipment Location System Type Fan Motor Heat Type Fan & Motor Combined Efficiency Static Pressure Across Fan I Short Form Job: DEC 22, 2006 Htg Clg Inside db (OF) 70 75 Inside RH (%) - 50 Inside wb (OF) - 63 Design TD (OF) 28 15 Cooling Equipment TRANE :I 2TTB3042A100 STRAIGHT COOL / EER / SEER 13.0 ible Cooling 31400 MBtuh it Cooling 9100.0 MBtuh Cooling 40500 MBtuh ng Air Temp 55.0 OF iI Cooling Fan 1400 cfm A/C THREE VAV DRAWTHRU 10.0 % 0.1 in H2O NAME Area Heat Sensible I Latent Htg Clg Time ft2 Loss Gain Gain cfm cfm UNIT 3 1379 18965 30414 10923 1349 1362 Jul 1500 BATH 3 56 2599 1596 2176 51 38 Jul 1500 A/C THREE 1435 21563 32011 I 13099 1400 1400 Jul 1500 Right -Suite Commercial Load Calculation UNIT 3 For: DRAWDY OFFICE PARK PHASE III MIDWAY RD, FT. PIERCE, FL Zone: UNIT 3 LWH: 1379 x 1.0 x 9.0 1. DESIGN CONDITIONS - COOLING Dry Bib Outdoor Conditions 90 Indoor Conditions —> 75 TOD Correction —> 0 ( Jul 1500 ) RH Moisture 59 50 Job: DEC 22, 2006 Range Wet Bib 15 78 63 Difference 15 I 61.5 - Mult - 1.0 ] — 2. GLAZING SOLAR HEAT GAIN ( Lat = 27.45I -N Const Wt = M ) Type Orien Area Tilt ShdF IntShd SCMult SC Sens/A Sens GLAZ 1 E 62 90 --- N 1�i 00 0.30 18.4 1148 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp GLAZ 1 E 62 62 1.040 WALL 1 N 369 369 0.089 B WALL 1 E 315 211 0.089 B WALL 1 W 243 222 0.089 B DOOR 1 e 21 21 1.100 DOOR 2 e 21 21 1.100 DOOR 3 w 21 21 0.460 FLOR 1 - 103 103 0.810 ROOF 1 - 1379 1379 0.060 R-4 4. INTERNAL HEAT GAIN _ PEOPLE Activity Total Schedule ftZ/prsn # people Office 150 0 9 8to6 0 0 0 LTD Shad Clr Sens 14.5 N - 941 10.5 N D 345 24.5 N D 459 14.5 N D 286 14.5 - - 335 14.5 - - 335 14.5 - - 140 0.0 - - 0 66.5 - D 5502 Sens Latent Sensible Latent Btuh/prsn Btuh/prsn 250 200 2298 1839 0 0 0 0 WrightSC3 t Right -Suite Commercial 5.8.13 RSC50847 I 2006-Dec-2714:21:00 C:XDRAWDY BROS PHASE 11.rsc Page 1 LIGHTS Type Total Factor Space _ Schedule W/ft2 W W Btuh/W fract _ Fluorescent 2.00 0 2758 4.10 1.0 11308 ' 8to6 - Fluorescent 0.00 0 0 4.10 1.0 0 • Fluorescent 0.00 0 0 4.10 1.0 0 Fluorescent 0.00 0 0 4.10 1.0 0 PLUG LOADS / APPLIANCES Application Usage otal Sensible Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6 0.70 0 1.00 965 3 0 3294 0 #/ft2 # 0.000 0.00 1.00 0 0 0 0 0 #/ft2 # 0.000 0.00 1.00 0 0 0 0 0 #/ft2 # 0.000 0.00 1.00 0 0 0 0 0 #/ft2 # 0.000 0.00 1.00 0 0 0 0 0 #/ft2 # 0.000 0.00 1.00 0 0 0 0 0 MOTORS Power (hp) Load To al Sensible Schedule #/ft2 # factor Btuh 0.00 0.0 0 1.00 0 0 0.00 0.0 0 1.00 i 0 0 0.00 0.0 0 1.00 U 0 0 5. INFILTRATION Sens Latent 30 cfm x db Temp Diff 15.0 x 1.10 495 > x Moist. Diff 61.5 x 0.69 1274 6. SUBTOTAL COOLING LOAD FOR SPACE I 26886 10923 7. SUPPLY DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensible Gain 0 8. COOLING FAN SIZING Sum of Duct Gain (7), Line (6) & Drawthru Fan - 27383 • (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 27383) / ( 1.10 x 120.0 ) = 1246 Actual Cooling Fan > = 1362 • 9. VENTILATION 184 cfm -> x db Temp Diff 15.0 x 1.10 3031 -> x Moist. Diff 61.5 x 0.69 7810 10. RETURN AIR LOAD FROM LIGHTING AND ROOF Lights Total power ( W) 0 11308 RA Roof Load from Line 3 (+) 0 RA Ceiling Load Credit from Line 3 (-) 0 Wngh tSOft Right-Suke Commercia15.8.13 RSC50847 I 2006-Dec-2714:21:00 C:IDRAWDY BROS PHASE IIne Page 2 i 11. RETURN DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensi le Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 30414 10923 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval GLAZ 1 E 62 62 1.100 WALL 1 N 369 369 0.089 WALL 1 E 315 211 0.089 WALL 1 W 243 222 0.089 DOOR 1 e 21 21 1.100 DOOR 2 e 21 21 1.100 DOOR 3 w 21 21 0.460 FLOR 1 - 103 103 0.810 ROOF 1 - 1379 1379 0.060 70 - 42) = 28 Mult = 1.0 HTD Loss 28.0 1922 28.0 920 28.0 525 28.0 553 28.0 647 28.0 647 28.0 270 28.0 2336 28.0 2317 15. INFILTRATION Loss 60 cfm x db Temp Diff 28.0 x 1.10 1846 16. SUBTOTAL HEATING LOAD FOR SPACE I 11983 17. SUPPLY DUCT HEAT LOSS Loss factor 0.00 x Line 16 Loss 0 18. VENTILATION 184 cfm x db Temp Diff 28.0 x J.10 5658 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 or 2 pane ) 244 cfm x 1.48 g/100cfm/d - 3.6 gpd 1324 20. RETURN DUCT HEAT LOSS Loss factor 0.00 x Line 16 Loss 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 18965 wrvghtsoft Right -Suite Commercial 5.8.13 RSC50847 2006-Deo-271421:00 CMRAWDY BROS PHASE 11.rsc Page 3 Right -Suite Commercial Load Calculation BATH 3 Job: DEC 22, 2006 For: DRAWDY OFFICE PARK PHASE III MIDWAY RD, FT. PIERCE, FL Zone: BATH 3 - I LWH: 7.0 x 8.0 x 9.0 1. DESIGN CONDITIONS - COOLING I ( Jul 1500 ) Dry Bib RH Moisture Range Wet Bib Outdoor Conditions —> 90 59 15. 78 Indoor Conditions 75 50 63 TOD Correction —> 0 Difference 15 I 61.5 II Mult - 1.0 ] — 2. GLAZING SOLAR HEAT GAIN ( Lat = 27.45'N Const Wt = M ) Type Orien Area Tilt ShdF IntShd SCLIt SC Sens/A Sens n/a 0 n/a 0 0 40 0.00 0.0 0 3. TRANSMISSION GAINS I Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens WALL 1 W 72 72 0.089 B 14.5 N D 93 FLOR 1 - 8 8 0.810 0.0 - - 0 ROOF 1 - 56 56 0.060 R-4 66.5 - D 223 4. INTERNAL HEAT GAIN Sens Latent PEOPLE Activity Total Sensible Latent Schedule ftz/prsn # people Btuh/prsn Btuh/prsn Restroom 150 0 0 210 140 78 52 8to6 0 0 0 I 0 0 0 0 wrightsoft Right -Suite Commercial 5.8.13 RSC50847 I 2006-Dec-27 14:21:00 C:IDRAWDY BROS PHASE 11.rsc Page 1 - LIGHTS Type Total Factor Space - Schedule W/ftz W W Btuh/W fract - Fluorescent 1.00 0 56 4.10 1.0 230 8to6 Fluorescent 0.00 0 0 4.10 1.0 0 • Fluorescent 0.00 0 0 4.10 1.0 0 -• Fluorescent 0.00 0 0 4.10 1.0 0 PLUG LOADS / APPLIANCES Application Usage otal Sensible Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6 0.70 0 1.00 39 3 0 134 0 #/ftz # 0.000 0.00 1.00 0 0 0 0 0 #/ftz # 0.000 0.00 1.00 0 0 0 0 0 #/ftz # 0.000 0.00 1.00 0 0 0 0 0 #/ftz # 0.000 0.00 1.00 0 0 0 0 0 #/ftz # 0.000 0.00 1.00 0 0 0 0 0 MOTORS Power (hp) Load Total Sensible Schedule #/ftz # factor , Btuh 0.00 0.0 0 1.00 4 0 0 0.00 0.0 0 1.00 i 0 0 0.00 0.0 0 1.00 0 0 0 5. INFILTRATION Sens Latent 0 cfm > x db Temp Diff 15.0 x 1.10 0 > x Moist. Diff 61.5 x 0.69 0 6. SUBTOTAL COOLING LOAD FOR SPACE I 758 2176 7. SUPPLY DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensible Gain 0 8. COOLING FAN SIZING Sum of Duct Gain (7), Line (6) & Drawthru an = 772 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 772) / ( 1.10 x 120.0 ) = 35 Actual Cooling Fan 38 9. VENTILATION 50 cfm > x db Temp Diff > x Moist. Diff 10. RETURN AIR LOAD FROM LIGHTING AND ROOF Lights Total power( W ) RA Roof Load from Line 3 (+) RA Ceiling Load Credit from Line 3 (-) wrightsoft Right -Suite Commercial 5.8.13 RSC50847 C:IDRAWDY BROS PHASE 11.rsc 5.0 x 1.10 w r -1 n nn A 824 2124 230 0 0 2006-Dec-2714:21:00 Page 2 11. RETURN DUCT HEAT GAIN I Gain factor 0.00 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) I 1596 2176 SPACE HEATING LOAD CALCULATION • 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval WALL 1 W 72 72 0.089 FLOR 1 - 8 8 0.810 ROOF 1 - 56 56 0.060 _ ( 70 - 42) = 28 Mult = 1.0 ] — HTD* Loss 28.0 179 28.0 181 28.0 94 15. INFILTRATION Loss 0 cfm x db Temp Diff 28.0 x 1.10 0 16. SUBTOTAL HEATING LOAD FOR SPACE I 455 17. SUPPLY DUCT HEAT LOSS I Loss factor 0.00 x Line 16 Loss 0 18. VENTILATION 50 cfm x db Temp Diff 28.0 x 1.10 1539 19. HUMIDIFICATION Inside RH desired 40.0 (Max = 32.0 for 1 pane ) # of Glazing panes 0.0 (Max = 52.0 for 2 pane ) 50 cfm x 3.20 g/100cfm/d �I 1.6 gpd 605 20. RETURN DUCT HEAT LOSS Loss factor 0.00 x Line 16 Loss 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 2599 wrightsoft Right-SuHe Commercial 5.8:13 RSC50847 I 2006-Dec-27 14:21:00 C:IDRAWDY BROS PHASE 11.= Page 3