Loading...
HomeMy WebLinkAboutPROJECT SUMMARYFlorida Energy Efficiency Code For Building Construction SCANNED Florida Department of Community Affairs �Y EnergyGauge FLA/COM 2004 v3.00 -- Form 40OA-2004 StLude(Ql iod A: Whole Building Performance Method for Commercial Buildings Effective December 8, 2006 1 , I f Short Desc: DRAWDY Owner: DRAWDY BROS Addressl: MIDWAY RD Address2: MIDWAY RD Type: Office Jurisdiction: ST LUCIE COUN Cond Area: 4149 SF No of Storeys: 1 Permit No: 0 12/27/2006 PROJECT SUMMARY Description: DRAWDY OFFICE PHASE City: FT. PIERCE State: FL Zip: 34981 Class: New Finished building ST LUCIE COUNTY, FL (661000) Cond & UnCond Area: 4149 SF Area entered from Plans 0 SF Max Tonnage 3.4 If different, write in: EnergyGauge FLA/COM 2004 v3.00 1 Component ,L Gross Energy Use LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from lIMPOR TANT NOTE: An h along with this Compliance 12/27/2006 Summary Design 3,308.7 List? Criteria Result 3,695.2 PASSES PASSES None Entered PASSES None Entered None Entered None Entered Yes/No/NA report of this design building must be submitted EnergyGauge FLA/COM 2004 v3:00 01 TIFICATIONS I hereby certify that the plans and speci!ipaWns covered by this calculation are in compliance with the Florida Energy Code I Prepared By Building Official: Date: Date: I certifythat this building is in com lian le with the Florida Energy Efficiency Code 9 P 9Y Y Owner Agent: Date: If Required by Florida law, I hereby certify (*) that the system design is in compliance with the FLorida Energy Efficiency Code Architect: Reg No: Electrical Designer: I Reg No: Lighting Designer: Reg No: i Mechanical Designer: I Reg No: Plumbing Designer: L.- Reg No: (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. 12/27/2006 1 EnergyGauge FLA/COM 2004 v3.00 3 i Project: DRAWDY Title: DRAWDY OFFICE PHASE H Type: Office (WEA File: DAYTONABEACH.TMY) Wh 6le Building Compliance Design Reference Total 90.09 100.00 $3,309 $3,695 ELECTRICITY(MB A 90.09 100.00 Wh/$) 66042 $3,309 73317 $3,695 AREA LIGHTS 12.63 19.06 9261 13977 $464 $704 MISC EQUIPMT 12.43 12.43 9119 9119 $457 $460 PUMPS & MISC 0.12 0.12 95 97 $5 $5 SPACE COOL 24.74 23.22 18135 17014 $909 $858 VENT FANS 40.17 45.16 29432 33110 $1,475 $1,669 Credits & Penalties (if any): Modified Points: = 90.09 PASSES I External Lighting Compliance Description Category Allowance Area or Length ELPA CLP I (W/Unit) or No. of Units (W) (W) (Sgft or ft) I I None 12/27/2006 EnergyGauge FLA/COM 2004 v3.00 4 Project: DRAWDY Title: DRAWDY OFFICE PHASE H Type: Office (WEA File: DAYTONABEACH.TMY) Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- ID (sq.ft) Tasks CP CP ance PrOZo1Sp1 16 Office - Open Plan 1,370 1 2 1 PASSES PrOZo2Sp1 16 Office - Open Flan 1,334 1 2 1 PASSES PrOZo3Sp1 16 Office - Open Plan 1,446 1 2 1 PASSES IPASSES 12/27/2006 EnergyGauge FLA/COM 2004 v3.00 5 r: M Project: DRAWDY Title: DRAWDY OFFICE PHASE H Type: Office (WEA File: DAYTONABEACH.TMY) System Report Compliance PrOSyl System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 tu/h 13.00 13.00 9.00 PASSES Cooling Capacity Air Handling Air Handler (Supply - 0.80 0.90 PASSES System -Supply Constant Volume Pr0Sy2 System 2 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 9.00 PASSES Cooling Capacityl Air Handling System -Supply Air Handler (Supply) - Constant Volume 0.80 0.90 PASSES PrOSy3 System 3 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 6�5000 Btu/h 13.00 13.00 9.00 PASSES Air Handling System -Supply Cooling Capacity Air Handler (Supply) - Constant Volume 0.80 0.90 PASSES �— PASSES l Plant Compliance l Description Installed Size Design No I Eff Min Design Min Category Comp Eff IPLV IPLV liance I None 12/27/2006 EnergyGauge FLA/COM 2004 v3.00 i Water Heater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss liance I None IPiping System Compliance Category I[F] ipe Dia Is Operating Ins Cond Ins Req Ins Compliance inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] .SF.F] I None Project: DRAWDY I Title: DRAWDY OFFICE PHASE H Type: Office I (WEA File: DAYTONABEACH.T Other Required Compliance Category Section I Requirement (write N/A in box if not applicable) Check Infiltration System Ventilation ADS T & B Motors Lighting O & M Roof/Ceil Report 406.1 407.1 409.1 410.1 410.1 414.1 415.1 102.1 404.1 101 Infiltration Criteria have been met HVAC Load sizing has been performed Ventilation criteria have been met Duct sizing and Design have been performed Testing and Balancing will be performed Motor efficiency criteria have been met Lighting criteria have been met Operation/maintenance manual will be provided to owner R 19 for Roof Deck with supply plenums beneath it Input Report Print -Out from EnergyGauge F1aCom attached? El 12/27/2006 EnergyGauge FLA/COM 2004 v3.00 EnergyGauge FLA/COM 2004 v3.00 INPUT DATA REPORT Project Information Project Name: DRAWDY Project Title: DRAWDY OFFICE PHASE II Address: MIDWAY RD MIDWAY RD State: FL Zip: 34981 Y BROS CONSTRUCTIO Zones Orientation: North Building Type: Office Building Classification: New Finished building No.of Storeys: 1 GrossArea: 4149 SF No Acronym Description Type Area Multiplier Total Area [sf] [sfj 1 PrOZo1 Zone 1 CONDITIONED 1369.9 1 1369.9 ❑ 2 PrOZo2 Zone 2 CONDITIONED 1333.7 1 1333.7 ❑ 3 PrOZo3 Zone 3 CONDITIONED 1445.6 1 1445.6 ❑ 12/27/2006 EnergyGauge FLA/COM 2004 v3.00 , 1 U Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume [ft] [ft] [ft] plier [sf] [cf] In Zone: PrOZol 1 PrOZo1Spl ZoOSpl Office - Open Plan 32.93 41.60 9.00 1 1369.9 12329.0 In Zone: PrOZo2 1 PrOZo2Spl ZoOSpl Office - Open Plan 32.06 41.60 9.00 1 1333.7 12003.3 In Zone: PrOZo3 1 Pr0Zo3Sp1 ZoOSpl Office - Open Plan 34.75 41.60 9.00 1 1445.6 13010.4 El Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: PrOZol In Space: PrOZo1Spl 1 Suspended Fluorescent General Lighting 8 126 1008 Manual On/Off 2 ❑ In Zone: PrOZo2 In Space: Pr0Zo2Sp1 1 Suspended Fluorescent General Lighting 8 126 1 - Manual-On/Off 2 In Zone: PrOZo3 In Space: Pr0Zo3Sp1 1 Suspended Fluorescent General Lighting 8 126 1008 Manual On/Off 2 Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity [Ib/cf] [h.sf.F/Btu] [Btu/sf.F] In Zone: PrOZol 12/27/2006 EnergyGauge FLA/COM 2004 v3.00 .� "it . r 1 I PrOZo1Wal 8"CMU/3/4"ISO 34.00 9.00 1 306.0 West 0.2642 9.696 62.72 3.8 ❑ BTWN24"oc/5/8 Gyp 2 PrOZo1Wa2 8"CMU/3/4"ISO 41.60 9.00 1 374.4 South 0.2642 9.696 62.72 3.8 ❑ BTWN24"oc/5/8 Gyp 3 PrOZo1Wa3 8"CMU/3/4"ISO 34.00 9.00 1 306.0 East 0.2642 9.696 62.72 3.8 ❑ BTWN24"oc/5/8 Gyp In Zone: PrOZo2 1 PrOZo2Wal 8"CMU/3/4"ISO 32.00 9.00 1 288.0 West 0.2642 9.696 62.72 3.8 ❑ BTWN24"oc/5/8 Gyp 2 PrOZo2Wa2 8"CMU/3/4"ISO 32.00 9.00 1 288.0 East 0.2642 9.696 62.72 3.8 ❑ BTWN24"oc/5/8 Gyp In Zone:' PrOZo3 1 PrOZo3Wal 8"CMU/3/4"ISO 41.60 9.00 1 374.4 North 0.2642 9.696 62.72 3.8 ❑ BTWN24"oc/5/8 Gyp 2 PrOZo3Wa2 8"CMU/3/4"ISO 35.00 9.00 1 315.0 West 0.2642 9.696 62.72 3.8 ❑ BTWN24"oc/5/8 Gyp 3 PrOZo3Wa3 8"CMU/3/4"ISO 35.00 9.00 1 315.0 East 0.2642 9.696 62.72 3.8 ❑ BTWN24"oc/5/8 Gym Windows----------. No Description Type Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area -- [Btu/hr sf F] [ft] [ft] plier [sf] In Zone: PrOZol In Wall: PrOZo1Wa3 1 PrOZo1Wa3Wi1 User Defined No 1.2500 0.70 0.58 6.00 8.00 1 48.0 ❑ 2 PrOZo1Wa3Wi2 User Defined No 1.2500 0.70 0.58 6.00 5.00 2 60.0 ❑ In Zone: PrOZo2 In Wall: PrOZo2Wa2 1 ' PrOZo2Wa2Wi1 User Defined No 1.2500 0.70 0.58 6.00 8.00 1 48.0 ❑ 2 PrOZo2Wa2Wi2 User Defined No 1.2500 0.70 0.58 8.00 5.00 2 80.0 ❑ 12/27/2006 EnergyGauge FLA/COM 2004 v3.00 l In Zone: PrOZo3 In Wall: PrOZo3Wa3 1 PrOZo3Wa3Wil User Defined No 1.2500 0.70 0.58 6.00 5.00 2 60.0 ❑ 2 PrOZo3Wa3Wi2 User Defined No 1.2500 0.70 0.58 6.00 8.00 1 48.0 ❑ Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.FBtu] In Zone: PrOZol In Wall: PrOZo1Wal 1 PrOZo1Wa1Drl Solid core flush No 3.00 7.00 1 21.0 0.3504 0.00 0.00 2.85 ❑ (2.25) In Zone: PrOZo2 In Wall: PrOZo2Wa1 1 PrOZo2Wa1Drl Solid core flush No 3.00 7.00 1 21.0 0.3504 0.00 0.00 2.85 ❑ (2.25) In Zone: PrOZo3 In Wall: PrOZo3Wa2 1 PrOZo3Wa2Dr1 Solid core flush No 3.00 7.00 1 21.0 0.3504 0.00 0.00 2.85 ❑ (2.25) Roofs No Description Type Width (Effec)-Multi_AreTilt Cond. Heat Cap Dens. R-Value [ft] [ft] plier [sf] [deg]-[Btu/hr.-Sf.-F]_[Btu/sf. F] [lb/cf] [h.sf.FBtu] In Zone: PrOZol EMT 1 PrOZo1Rfl Conc Tile/1/2"WD 41.60 32.93 1 1369.9 0.00 0.0474 2.15 16.45 21.1 ❑ Deck/WD Truss/6'Batt/Gyp In Zone: PrOZo2 1 PrOZo2Rfl Conc Tile/1/2"WD 41.60 32.06 1 1333.7 0.00 0.0474 2.15 16.45 21.1 ❑ Deck/WD Truss/6"BatdGyp In Zone: PrOZo3 1 PrOZo3Rfl Conc Tile/l/2"WD 41.60 34.75 1 1445.6 0.00 0.0474 2.15 16.45 21.1 ❑ Deck/WD Truss/6'Batt/Gyp k?/27/2006 EnergyGauge FLA/COM 2004 v3.00 4 Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] [ft] [ft] [Sf] [Sf] In Zone: In Roof: El Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value R [ft] plier [sf] [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu] In Zone: PrOZol 1 PrOZo1F11 1 ft. soil, concrete 41.60 32.93 1 1369.9 0.1745 54.00 108.00 5.73 ❑ floor, carpet and rubber pad In Zone: PrOZo2 1 Pr0Zo2F11 1 ft. soil, concrete 41.60 32.06 1 1333.7 0.1745 54.00 108.00 5.73 ❑ floor, carpet and In Zone: rOZo3 rubber pad 1 PrOZo3F11 1 ft. soil —concrete--41.60 34.75 1 1445.6 0.1745 54.00 108.00 5.73 ❑ floor, carpet and rubber pad Systems PrOSyl System 1 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 40500.00 13.00 9.00 ❑ Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - 1400.00 0.80 ❑ Constant Volume) 12/27/2006 EnergyGauge FLA/COM 2004 v3.00 PrOSy2 System 2 Constant Volume Air Cooled Split System < 65000 Btu/hr No. Of Units 1 Component Category Capacity Efficiency IPLV 1 2 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 40500.00 13.00 9.00 1400.00 0.80 PrOSy3 System 3 Constant Volume Air Cooled Split System < 65000 Btu/hr No. Of Units 1 Component Category Capacity Efficiency IPLV 1 2 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 40500.00 13.00 9.00 1400.00 0.80 13 Plant Equipment Category Size Inst.No Eff. IPLV Li Water -Heaters W-Heater Description Capacit3Cap.Unit IT Rt. Efficiency Loss Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage 11 Luminaires Luminaire [sf/ft/No] [W] 11 12/27/2006 EnergyGauge FLA/COM 2004 v3.00 6 u Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout? Temperature Conductivity Diameter Thickness [F] [ Btu-in/h.sf.F] [in] [in] Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/h.sf.F] ASHULTntA11Fr User Defined 1 1.2500 0.7000 0.5800 ❑ m Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat IIsed-[h.sf.FBtu IN [Btu/h.ft.F] [lb/cf] [Btu/Ib.F] 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000-❑_ BOARD,1/2IN 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 105 Mat1105 CONC BLK HW, 8IN, No 1.1002 0.6667 0.6060 69.00 0.2000 ❑ HOLLOW 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 244 Mat1244 PLYWOOD, 1/21N No 0.6318 0.0417 0.0660 34.00 0.2900 ❑ 185 Mat1185 CLAY TILE, PAVER, 3/81N No 0.0301 0.0313 1.0410 120.00 0.2000 ❑ 12/27/2006 EnergyGauge FLA/COM 2004 v3.00 7 Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1014 8"CMU/3/4"ISO BTWN24"oc/5/8 Gyp No No 0.26 9.70 62.72 3.8 ❑ Layer Material Material No. 1 105 CONC BLK HW, 81N, HOLLOW 2 269 .75" ISO BTWN24" oc 3 187 GYP OR PLAS BOARD,1/2IN Thickness Framing [ft] Factor 0.6667 0.000 ❑ 0.0625 0.000 ❑ 0.0417 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1041 Conc Tile/l/2"WD Deck/WD No No 0.05 2.15 16.45 21.1 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 185 CLAY TILE, PAVER, 3/8IN 0.0313 0.000 ❑ —2 244 PLYWOOD, 1/21N 0.0417 0.000 ❑ 3 187 GYP OR-PLAS-BOARD,1/21N 0.0417 0.000 ❑ 4 23 6 in. Insulation 0.5600 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density --RValue---- Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.17 54.00 108.00 5.7 ❑ 12/27/2006 Layer Material Material No. 1 265 Soil, 1 ft 2 48 6 in. Heavyweight concrete 3 178 CARPET W/RUBBER PAD Thickness [ft] 2.0000 0.5000 EnergyGauge FLA/COM 2004 v3.00 Framing Factor 0.000 0.000 0.000 Im 8 11 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [ib/cf] [h.sf.FBtu] 1058 Solid core flush (2.25) No Yes 0.35 2.9 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 279 Solid core flush (2.25") 0.000 ❑ 12/27/2006 EnergyGauge FLA/COM 2004 v3.00 9 . .• • d % ,