HomeMy WebLinkAboutREVISION 4-4-19OFFICE USE ONLY: SCANNED
DATE FILED: `F" 4-) � Lucia Coanfly PERMIT #
REVISION FEE: 0
RECEIPT #
1
LOCATION/SITE
ADDRESS: 140
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982.5652
(772) 462.1553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
'm
DETAILED DESCRIPTION OF PROJECT
CONTRACTOR INFORMATION: i
STATE of FL REG./CERT. #: 13W
BUSINESS NAME: cue
QUALIFIERS NAME: Ric.At-A - L
ADDRESS: 9\ a- gs (�-020I n I ,
CITY: !kW .4Y3- STATE: 4
PHONE (DAYTIME): - --y 3--
OWNER/BUILDER INFORMATION:
NAME:
ADDRESS:
Cl I Lt -7.� Lf - Q 4
ST. LUCIE CO CERT. #:
FAX:
CITY: STATE: ZIP:
PHONE (DAYTIME: FAX:
ARCIHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE (DAYTIME): FAX:
SLCCC. 9123109
Revised 06130117
F�E\/ISION
DA-
%Ava.3�`R LL EAEZ"�*% K
TECHNICAL SERVICES, LLC
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813) 480-3421
EVALUATION REPORT I FLORIDA BUILDING CODE, e" EDITION (2017)
Manufacturer: GACO WESTERN, LLC
200 West Mercer Street, Suite 202
Seattle, WA 98119
(800) 331-0196
www.gaeo.com
Manufacturing Plants: Waukesha, WI
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category:
Roofing
Subcategory:
Cements -Adhesives-Coatings
Code Sections:
1507.14.3, 1507.15.2
Properties:
Physical Properties
REFERENCES
Issued December 10, 2018
Enti
Reaort'No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
GWI-024-02-02
ASTM D 6694
2008
PRI Construction Materials Technologies (TST5878)
GWI-026-02-01
ASTM D 6694
2008
PRI Construction Materials Technologies (TST5878)
GWI-042-02-01
ASTM D 6694
2008
PRI Construction Materials Technologies (TST5878)
GWI-043-02-01
ASTM D 6694
2008
PRI Construction Materials Technologies (TST5878)
GWI-044-02-01
ASTM D 6694
2008
PRI Construction Materials Technologies (TST5878)
GWI-645-02-01
ASTM D 6083
2005e01
PRI Construction Materials Technologies (TST5878)
GWI-062-02-01
ASTM D 6694
2008
PRODUCT DESCRIPTION
i'xoducts :°; ...
% ecification, ..Desch
tionz
GacoFlex A-31
ASTM D 6083
Acrylicquick-set elastomeric coating that is brush, roller orspray-applied.
GacoFlex S-10
ASTM D 6694
Silicone elastomeric coating that is brush, roller orspray-applied.
GacoFlex S-20
ASTM D 6694
Silicone solvent -free, single -component, moisture -cured, waterproof
elastomeric coating that is brush, roller orspray-applied.
GacoFlex S-21
ASTM D 6694
Silicone solvent -free, single -component, moisture -cured, waterproof
elastomeric coating that is brush, roller orspray-applied.
GacoRoof GR-16
1 ASTM D 6694
1Silicone elastomeric coating that is brush, roller ors ra -a lied.
G f' — vZ,c
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR COMP 1�iE
nC-VIEWED BY
DATE
PLANS AND PER IT
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
k
FL14724-R4 Page 1 of 7
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
r
CREEK
TF-cHNICAL. SF_PV10E5, LLC
APPLICATION
The following notes shall be observed when using the application tables below:
1. All surfaces shall be repaired, clean, dry, and free of debris prior to application.
2. Roof coating may be spray, brush or roller applied.
3. Applications are valid for new and existing roof systems.
GACO WESTERN, LLC
GacoFlex Roof Coatings
BSI � '7 ��'_!� �•.�'p, ,.vrd �1 't ��
� � Appiicattorl
of Ga�oFlex,A-31 ' ; ,
;Substrate
�n m um Applicatiari Rate'
GacoFlex A-31 applied in three (3) coats (base, intermediate and top) at
Spray Polyurethane Foam Roofs
a minimum rate of 1.25 gal/100 ft2 per coat
'Appltcatton
of GacoFlex S 1a
,,. , .„ ,
8ukstrate ,`.,.
(ymtmufitApp6cattgn,Rate
ew.or=,.Extsttn '
Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/100 fe
followed by one of the following:
Acrylic Coatings
-One coat of GacoFlex S-10 applied at a minimum rate of 2.2 gal/100ft2
-Two (2) coats (base and top) of GacoFlex S-10 applied at a minimum
rate of 1.1 gal/100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.4 gaU100 ff
followed by one of the following:
BUR Membranes - Smooth -surfaced
-One coat of GacoFlex S-10 applied at a minimum rate of 2.2 gal/100ft2
-Two ,(2) coats (base and top) of GacoFlex S-10 applied at a minimum
rate of 1.1 gal/100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/100
followed by one of the following:
Galvanized Steel Metal Panels
-Onecoat of GacoFlex S-10 applied at a minimum rate of 2.2 gal/100ft2
-Two (2) coats (base and top) of GacoFlex S-10 applied at a minimum
rate of 1.1 gal/100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/100
followed by one of the following:
KEE Single -Ply Membrane
-One coat of GacoFlex S-10 applied at a minimum rate of 2.2 gal/100ft2
-Two (2) coats (base and top) of GacoFlex S-10 applied at a minimum
rate of 1.1 gal/100ft2 per coat
Primed with GacoFlex E5320 Primer at a rate of 0.3 gal/l00 ft
followed by one of the following:
PVC Single -Ply Membranes
-One coat of GacoFlex S-10 applied at a minimum rate of 2.2 gal/100W
-Two (2) coats (base and top) of GacoFlex S-10 applied at a minimum
rate of 1.1 gal/100ft2 per coat
Primed with GacoFlex E5320 Primer at a rate of 0.5 gaV100 ft
followed by one of the following:
SBS Modified Bitumen Membranes - Granule -surfaced
-One coat of GacoFlex S-10 applied at a minimum rate of 2.2 gal/100ft2
-Two (2) coats (base and top) of GacoFlex S-10 applied at a minimum
rate of 1.1 gal/100ft2 per coat
Applied according to one of the following:
-One coat of GacoFlex S-10 applied at a minimum rate of 2.2 gal/100ft2
Spray Polyurethane Foam Roofs
-Two (2) coats (base and top) of GacoFlex S-10 applied at a minimum
rate of 1.1 gal/100ft2 per coat
GW18002.1 FL14724-R4 Page 2 of 7
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
' REEK
iai
r�r.
SEPWICES, LLC
GACO WESTERN, LLC
: i �:5-1 tl GacoFlex Roof Coatings
A if�atlon of GacoFlex 5 20 tt
:Substrate
, _„Mlnrmum Application Ra#e
Primed with GacoFlex E-5320 Primer at a rate of 0.3 gaU100
followed by one of the following:
Acrylic Coatings
-One coat of GacoFlex S-20 applied at a minimum rate of 1.5 gal/100ft2
-Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum
rate of 0.75 gal/100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.5 gal/100 IY
followed by one of the following:
APP Modified Bitumen Membranes - Granule -surfaced
-One coat of GacoFlex S-20 applied at a minimum rate of 1.5 gal/100ft2
-Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum
rate of 0.75 gal/IOW per coat
GacoFlex A-4271 BleedTrap Base coat at a rate of 1.0 gai/100 ft
then primed with GacoFlex E-5320 Primer at a rate of 0.2 gal/100 ft
followed by one of the following:
APP Modified Bitumen Membranes - Granule -surfaced
One coat of GacoFlex S-20 applied at a minimum rate of 1.5 gal/100 ft2
-Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum
rate of 0.75 gal/100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.5 gal/100 ft
followed by one of the following:
APP Modified Bitumen Membranes - Smooth -surfaced
-One coat of GacoFlex S-20 applied at a minimum rate of 1.5 gal/100ft2
-Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum
rate of 0.75 gai/100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.4 gal/100 ft
followed by one of the following:
BUR Membranes - Smooth -surfaced
-One coat of GacoFlex S-20 applied at a minimum rate of 1.5 gal/100ft2
-Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum
rate of 0.75 gal/100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.3 gaV100 ft
followed by one of the following:
EPDM Single -Ply Membranes
-One coat of GacoFlex S-20 applied at a minimum rate of 1.5 gal/100ft2
-Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum
rate of 0.75 gaU100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/100.ft
followed by one of the following:
Galvanized Steel Metal Panels
-One coat of GacoFlex S-20 applied at a minimum rate of 1.5 gal/100ft2
-Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum
rate of 0.75 gaU100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/100 fe
followed by one of the following:
KEE Single -Ply Membrane
-One coat of GacoFlex S-20 applied at a minimum rate of 1.5 gal/100 ft2
-Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum
rate of 0.75 gal/100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/100
followed by one of the following:
PVC Single -Ply Membranes
-One coat of GacoFlex S-20 applied at a minimum rate of 1.5 gal/100ft2
-Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum
rate of 0.75 gal/100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.5 gal/100 fe
followed by one of the following:
SBS Modified Bitumen Membranes - Granule -surfaced
-One coat of GacoFlex S-20 applied at a minimum rate of 1.5 gal/100ft2
-Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum
rate of 0.75 gal/100ft2 per coat
GW 180021 FL14724-R4 Page 3 of 7
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
y� purlt�
GACO WESTERN, LLC
GacoFlex Roof Coatings
` :pip a on ofi GacoFlex 5'20
Substrate
MrrnmtiMate
GacoFlex A-4271 BleedTrap Base coat at a rate of 1.0 gal/100
then primed with GacoFlex E5320 Primer at a rate of 0.2 ga1/100 ftZ
followed by one of the following:
S85 Modified Bitumen Membranes - Granule surfaced
_One coat of GacoFlex S-20 applied at a minimum rate of 1.5 gal/1DOftZ
-Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum
rate of 0.75 gal/100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.5 gaU100 ft
followed by one of the following:
SBS Modified Bitumen Membranes - Smooth -surfaced
-One coat of GacoFlex S-20 applied at a minimum rate of 1.5 gal/100ftZ
-Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum
rate of 0.75 gal/100ftZ per coat
Applied according to one of the following:
-One coat of GacoFlex S-20 applied at a minimum rate of 1.5 gal/100fe
Spray Polyurethane Foam Roofs
-Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum
rate of 0.75 gal/100ftZ per coat
' Applicaftori of�Gaaol=iex'S 21� ' ,
Stlbstrafe r � i�rn m'Appitcatran Rate ,
_ imu
tow.orExtstin
Primed with GacoFlex E-5320 Primer at a rate of 0.5 gal/100 ft
followed by one of the following:
APP Modified Bitumen Membranes - Granule -surfaced -One coat of GacoFlex S-21 applied at a minimum rate of 1.5 gal/100fe
-Two (2) coats (base and top) of GacoFlex S-21 applied at a minimum
rate of 0.75 gal/100ftZ per coat
GacoFlex A-4271 BleedTrap Base coat at a rate of 1.0 gal/100 ft
then primed with GacoFlex E-5320 Primer at a rate of 0.2 gal/100 ftZ
followed by one of the following:
APP Modified Bitumen Membranes - Granule -surfaced
-One coat of GacoFlex 8-21 applied at a minimum rate of 1.5 gal/100ftZ
-Two (2) coats (base and top) of GacoFlex S-21 applied at a minimum
rate of 0.75 gal/100ftZ per coat
Primed with GacoFlex E5320 Primer at a rate of 0.3 gal/100 ft
followed by one of the following:
EPDM Single -Ply Membranes
-One coat of GacoFlex S-21 applied at a minimum rate of 1.5 gal/100ftZ
-Two (2) coats (base and top) of GacoFlex S-21 applied at a minimum
rate of 0.75 gal/100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/100
followed by one of the following:
Galvanized Steel Metal Panels
-One coat of GacoFlex S-21 applied at a minimum rate of 1.5 gal/10DftZ
-Two (2) coats (base and top) of GacoFlex S-21 applied at a minimum
rate of 0.75 gaUl00ftZ per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/100 ft
followed by one of the following:
Hypalon Single -Ply Membranes
-One coat of GacoFlex S-21 applied at a minimum rate of 1.5 gal/100ftZ
-Two (2) coats (base and top) of GacoFlex S-21 applied at a minimum
rate of 0.75 gal/100ftZ per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.3 gaU100
followed by one of the following:
KEE Single -Ply Membrane
-One coat of GacoFlex S-21 applied at a minimum rate of 1.5 gay
-Two -Two (2) coats (base and top) of GacoFlex S-21 applied at a minimum
rate of 0.75 gal/100ft2 per coat
GW18002.1 FL14724-R4 Page 4 of 7
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GACO WESTERN, LLC
GacoFlex Roof Coatings
,, , � �►pplt�ation of GacoFlex S 2 1
�Substrate� , �
' �, � MlnlmumApp)isaUAn Rt�te' ` ;
�lew;or�FaclsUn �: ..
Primed with GacoFlex E5320 Primer at a rate of 0.3 gaU100 ft
followed by one of the following:
PVC Single -Ply Membranes
-One coat of GacoFlex S-21 applied at a minimum rate of 1.5 gal/100ft2
-Two (2) coats (base and top) of GacoFlex S-21 applied at a minimum
rate of 0.75 gal/100flper coat
Primed with GacoFlex E5320 Primer at a rate of 0.5 gal/100 ft
followed by one of the following:
SBS Modified Bitumen Membranes - Granule -surfaced
-One coat'of GacoFlex S-21 applied at a minimum rate of 1.5 gal/100fe
-Two (2) coals (base and top) of GacoFlex S-20 applied at a minimum
rate of 0.75 gal/100ft2 per coat
GacoFlex A-4271 BleedTrap Base coat at a rate of 1.0 gal/100 f
then primed with GacoFlex E-5320 Primer at a rate of 0.2 gal/100 ft2
followed -by one of the following:
SBS Modified Bitumen Membranes - Granule -surfaced
One coat of GacoFlex S-21 applied at a minimum rate of 1.5 gal/100ft2
-Two (2) coats (base and top) of GacoFlex S-21 applied at a minimum
rate of 0.75 gaU100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.5 gal/100 ft
followed by one of the following:
SBS Modified Bitumen Membranes - Smooth -surfaced
-One coat of GacoFlex S-21 applied at a minimum rate of 1.5 gal/100ft2
-Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum
rate of 0.75 gal/100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/100 ft
followed by one of the following:
TPO Single -Ply Membranes
-One coat of GacoFlex S-21 applied at a minimum rate of 1.5 gal/100ft2
Two'(2) coats. (base and top) of GacoFlex 5-21 applied at a minimum
rate of 0.75 gaU100ft2 per coat
Applied according to one of the following:
-One coat of GacoFlex S-21 applied at a minimum rate of 1.5 gal/100ft2
Spray Polyurethane Foam Roofs
-Two (2) coats (base and top) of GacoFlex S-21 applied at a minimum
rate of 0.75 gal/100ft2 per coat
, Applicakrobf
n GacoRooF GR 16 ,
Substrate
MlnimumAppUcatlon Rate
IN
Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/100 ft
followed by one of the following:
Acrylic Coatings
-one coat of GacoRoof GR-16 applied at a minimum rate of 2 gal/100ft2
-Two (2) coats (base and top) of GacoRoof GR-16 applied at a minimum
rate of 1 gal/100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.4 ga11100 le
followed by one of the following:
BUR Membranes - Smooth -surfaced
-One coat of GacoRoof GR-16 applied at a minimum rate of 2 gal/100ft2
-Two (2) coats (base and top) of GacoRoof GR-16 applied at a minimum
rate of 1 gal/100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.3 gaU100 ft
followed by one of the following:
EPDM Single -Ply Membranes
-One coat of GacoRoof GR-16 applied at a minimum rate of 2 gal/100ft2
-Two (2) coats (base and top) of GacoRoof GR-16 applied at a minimum
rate of 1 gal/100ft2 per coat
GW16002.1 FL14724-R4 Page 5 of 7
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GACO WESTERN, LLC
GacoFlex Roof Coatings
ryaTECHNICAL
l � ��' � ppl�catton
A
of GacoRoof GR 16
5ubstraie `
Newt or.';:Exts{In
Mtrnfnufft Appltcatton ate
Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/100 ft
followed by one of the following:
Galvanized Steel Metal Panels
-One coat of GacoRoof GR-16 applied at a minimum rate of 2 gaill00ftz
-Two (2) coats (base and top) of GacoRoof GR-16 applied at a minimum
rate of 1 gal/100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/100 ft
followed by one of the following:
KEE Single -Ply Membrane
-One coat of GacoRoof GR-16 applied at a minimum rate of 2 gal1100ft2
-Two (2) coats (base and top) of GacoRoof GRA 6 applied at a minimum
rate of 1 gal/100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.3 gaU100 ft
followed by one of the following:
PVC Single -Ply Membranes
-One coat of GacoRoof GRA6 applied at a minimum rate of 2 gal/100ft2
-Two (2) coats (base and top) of GacoRoof GR-16 applied at a minimum
rate of 1 gal/100ft2 per coat
Primed with GacoFlex E-5320 Primer at a rate of 0.5 gal/100 ft
followed by one of the following:
SBS Modified Bitumen Membranes - Granule -surfaced
-One coat of GacoRoof GR-16 applied at a minimum rate of 2 gaI/100ft2
-Two (2) coats (base and top) of GacoRoof GR-16 applied at a minimum
rate of 1 gal/100ft2 per coat
Applied according to one of the following:
-One coat of GacoRoof GR-16 applied at a minimum rate of 2 gal/100ft2
Spray Polyurethane Foam Roofs
-Two (2) coats (base and top) of GacoRoof GR-16 applied at a minimum
rate of 1 gal/100ft2 per coat
GW18002.1
FL14724-R4
6of7
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not
specifically addressed herein.
r�
'TCIRREEK
. -
LIMITATIONS
GACO WESTERN, LLC
GacoFlex Roof Coatings
1. Fire classification is not within the scope of this evaluation.
2. Structural integrity of the roofing substrate or assembly is not within scope of this evaluation. Refer to the
appropriate product approval for installation of these components within an Approved roof assembly.
3. Installation of the evaluated products shall be in strict compliance with this evaluation report, the FBC, and
the manufacturer's published installation instructions. In the event of conflict, the more restrictive and FBC
compliant installation shall be enforced.
4. This product shall not be applied in inclement weather conditions.
5. This product shall not be applied over asphaltic shingles, metal shingles, fiber -cement shingles, quarry slate,
cement or clay roofing tile, or wood shingles or shakes.
6. This product may be used may be used as described in other current FBC product approval documents.
7. Refer to manufacturer's published instructions for proper storage and shelf life considerations.
8. All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61020-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest have demonstrated compliance with the Florida Building Code,
6"' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
%���RYI►R r►p���4
E
1/. No 74021 •
*� :*•
13 STATE OF
• �.
SS1ON A E?C� �.
►rinr
CERTIFICATION OF INDEPENDENCE
2018.12.10
SS77 %'-15:33:05
LJ -05'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
GW18002.1 FL14724-R4 Page 7 of 7
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.