BLOWER DOOR TEST FORM Permitting Departme;-
SCANNE® St. Lucie co,ir.:-
BY House Infiltration Test Certification
Prescriptive and Performance method
St Lurie County
Date: % Ir ! Permit #:
Contractor: W,� �, �� D� VRP �,� M4
Job Address:
2 .S N' o")A Wa
FL 3 !Y- I—
Construction: ,( New Construction — Coi1 plete
House Infiltration Test Results SLC
CFM (50) = r 5
Volume /
ACH (50) = CFM (50) x 60 / Volume = �O • 8
Passing results must be & ACH (50) or less
FBC, Energy
The building or dwelling unit shall be tested and verified
hour in Climate Zone 1, 2 and 3 air changes per hour in Cl
blower door at a pressure of 0.2 inches w. g. (50 Pascals).
Section 553.993(5) or (7), Florida Statutes or individuals li
approved third party. A written report of the results of tN
provided to the code official. Testing shall be performed
thermal envelope.
( ) Existing — After Addition
Zone 2
Date: 1131117
hanical Ventilation required less than 3 ACH
Pass ( ) Fail
having an air leakage rate of not exceeding 7 air changes per
late Zones 3 through 8. Testing shall be conducted with a
.esting shall be conducted by either individuals as defined in
nsed as set forth in Section 489.105 (3)(f), (g) or (i) or an
test shall be signed by the party conducting the test and
anytime after creation of all penetrations of the building
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testine ComDanv
Company Name: Pro -Duct Services
Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
I
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Martin Klein
License/Certification #: 5061633