Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEl V i ' i• FORM R405-2014 FLORIDA ENERGY EFFICIENCY ODE FOR BUILDING CONSTRUCTION Florida Department of Business and Profess onal Regulation - Residential Performance Method jiject Name: Ware Residence Builder Name: PUAL COONS CONSTRUCTION Street: 1316 Lone Pine DR [;,,9wner: SCANNED Permit Office: St Lucie 'CAy, State, Zip: Fort Pierce , FL , BY Permit Number:1710-0135 Jeremy S & Rebecca R Ware Jurisdiction: 611000 �t ��a�leO�%� y 'Design Location: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From'Plans) 9. Wall Types (4825.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Polystyrene Bead A991R=4.0 3125.00 it? b. Frame - Wood, Exterior R=19.0 1700.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= f Z 10. Ceiling Types (3101.0 sgft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 3101.00 ft2 6. Conditioned floor area above grade (ft2) 4476 b. N/A R= ft2 c. NIA R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(529.9 sqft.) Description Area a. Sup: Attic, Ret: 2nd Floor, AH: 2nd Floor 6 450 a. U-Factor: Dbl, U=0.32 348.15 1`12 b. Sup: Attic, Ret: 2nd Floor, AH: 2nd Floor 6 150 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.30 165.78 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit b. Central Unit 42.0 SEER:16.00 18.0 SEER:16.00 c. U-Factor: Dbl, U=0.35 16.00 ft2 SHGC: SHGC=0.24 13. Heating systems kBtulhr Efficiency d., U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: b. Electric Strip Heat 16.0 COP:1.00 Area Weighted Average Overhang Depth: 7.145 ft. Area Weighted Average SHGC: 0.230 14. Hot water systems a. Propane Cap: 40 gallons 8. Floor Types (4476.0 sgft.) Insulation Area EF: 0.590 a. Slab -On -Grade Edge Insulation R=0.0,, 3101.00 ft2 b. Conservation features b. Floor Over Other.Space R=19.0 1375.00 ft2 None c. N/A R= ft2 15. Credits Pstat Area: 0.118 Total Proposed Modified LI oads: 110.30 PASS Glass/Floor Total Baseline Loads: 131.02 I hereby certify that the plans and specifications covered by , ILview of the plans and 2VE ST,g7� ' this calculation are in compliance with the. Florida . ergy specifications covered by this Iculation indicates ti � ,:w Off, - '�o­ Code. compliance �jri,,'��, €.••' •`"��„ �O. vith the Florida Energy Code. Before construction is completed Irh,,:"K%. - PRETRED BY' DAT ': tf is building will be inspected for compliance with Section 553.908 * °_ I :hereby certify that this building, as designed, is in compliance Florida Statutes. COD with the Florida Energy Cnde. WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufact certified factory -sealed in accordance with R403.2.2.1. - Compliance with a selected proposed infiltration rate of 5.00 ACH5 R402.4.1.2. and an Air Barrier and Insulation Inspection Checklist in firer that the air handler enclosure qualifies as requires an envelope leakage test report in accordance with ocordance with R402.4.1.1. File COPY 12/20/2017 8:03 AM EnergyGauge® USA - FlaRes2014 R405.4.1 Compliant Software Page 1 of 5 FnRM R405-2014 ROJECT Title: Ware Residence Bedrooms: I 3 Address Type: Street Address Building Type: User Conditioned Area: 4476 Lot # Owner Name: Jeremy S & Rebecca R Ware Total Stories: 2 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: ERdder Name: PUAL COONS CONSTRUCTI Rotate Angle: 0 Street: 1316 Lone Pine DR Permit Office: St Lucie Cross Ventilation►: County: St. Lucie �Jorisdiction: 611000 Whole House Fan: City, State, Zip: Fort Pierce , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CL�MATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST LUCIE CO_INTL FL VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 3101 31010 2 Block2 1375 13750 SPACES I Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 Main 3101 31010 Yes 4 3 1 Yes Yes Yes 2 2nd Floor 1375 13750 No 0 0 1 Yes Yes Yes FLOO�S # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Floor Over Other Space 2nd Floor --- _-__ 1375 ft2 19 0 0 1 2 Slab -On -Grade Edge Insulatio Main 307 ft 0 3101 ft2 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 3359 ft2 0 ft2 Light 0.8 No 0.9 No 20 22.6 r ATTIC I V # Type Ventilation Vent Ratio (I in) Area RBS IRCC 1 Full attic Unvented 0 3101 ft2 N N 12/20/2017 8:03 AM EnergyGauge® USA - FlaRes2014 Section R 05.4.1 Compliant Software Page 2 of 5 7� FORM R405-2014 CEILING I # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) 2nd Floor 0 Blown 1375 ft' 0 Wood 2 Under Attic (Unvented) Main 0 Blown 1726 ft' 0 Wood WALLS I Adjacent Ca ' Width Height Sheathing Framing Solar Below Space 1 S Exterior Frame - Wood 2nd Floor 19 45 10 450.0 ftz 0 0.75 0 _ 2 N Exterior Frame - Wood 2nd Floor 19 45 10 450.0 ft2 0.1 0.75 0 _ 3 E Exterior Frame - Wood 2nd Floor 19 40 10 400.0 ftz 0.1 0.75 0 _ 4 W Exterior Frame - Wood 2nd Floor 19 40 10 400.0 ft' 0.1 0.75 0 _ 5 S Exterior Concrete Block - Polystyren Main 4 34 10 340.0 ftz 0 0 0.75 0 6 S Exterior Concrete Block - Polystyren Main 4 29 6 10 295.0 ftz 0 0 0.75 0 7 N Exterior Concrete Block - Polystyren Main 4 54 10 540.0 ftz 0 0 0.75 0 8 N Exterior Concrete Block - Polystyren Main 4 19 7 10 195.8 ftz 0 0 0.75 0 9 E Exterior Concrete Block - Polystyren Main 4 64 5 10 644.2 ftz 0 0 0.75 0 10 E Exterior Concrete Block - Polystyren Main 4 23 6 10 235.0 ftz 0 0 0.75 0 11 W Exterior Concrete Block - Polystyren Main 4 23 6 10 235.0 ftz 0 0 0.75 0 12 W Exterior Concrete Block - Polystyren Main 4 64 10 640.0 ftz 0 0 0.75 0 DOIORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated Main None .4 3 8 24 ftz WINDOWS Orientation shown is the en}ered, Proposed orientation. / Wall I Overhang v # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S 1 Vinyl Low-E Double Yes 0.32 0.22 22.8 ftz 1 ft 0 in 1 ft 0 in None None 2 N 2 Vinyl Low-E Double Yes 0.32 0.22 22.8 ftz 1 ft 0 in 1 ft 0 in None None 3 E 3 Vinyl Low-E Double Yes 0.32 0.22 26.7 ftz 1 ft 0 in 1 ft 0 in None None 4 W 4 Vinyl Low-E Double Yes 0.32 0.22 � 13.4 ft' 1 ft 0 in 1 ft 0 in None None 5 W 4 Vinyl Low-E Double Yes 0.32 6.0 ftz 1 ft0 in 1 ft0 in None None 6 S 5 Vinyl Low-E Double Yes 0.32 .22 33.3 ftz 10 ft 0 in 1 ft 0 in None None 7 S 5 Vinyl Low-E Double Yes 1�.22 0.35 0.24 16.0 ftz 10 ft 0 in 1 ft 0 in None None 8 S 6 Vinyl Low-E Double Yes 0.32 0.22 33.3 ftz 5 ft 0 in 1 ft 0 in None None " 9 N 7 Vinyl Low-E Double Yes 0.32 0.22 49.9 ftz 4 ft 0 in 1 ft 0 in None None 10 N 7 Vinyl Low-E Double Yes 0.3 0.25 33.3 ftz 4 ft 0 in 1 ft 0 in None None 11 N 7 Vinyl Low-E Double Yes 0.32 dl 22 6.9 ftz 4 ft 0 in 1 ft 0 in None None 12 N 7 Vinyl Low-E Double Yes 0.32 022 29.3 ftz 4 ft 0 in 1 ft 0 in None None 13 N 7 Vinyl Low-E Double Yes 0.3 L5 24.0 ftz 4 ft 0 in 1 ft 0 in None None 14 N 8 Vinyl Low-E Double Yes 0.3 0�25 48.0 ftz 23 ft 0 in 1 ft 0 in None None 15 E 9 Vinyl Low-E Double Yes 0.32 022 6.7 ftz 1 ft 0 in 1 ft 0 in None None 16 E 9 Vinyl Low-E Double Yes 0.32 022 9.8 ftz 1 ft 0 in 1 ft 0 in None None 17 E 9 Vinyl Low-E Double Yes 0.32 O.i 2 32.4 ft' 1 ft 0 in 1 ft 0 in None None 12I2=017 8:03 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FnRNA Rang-7n1A ------------ --- WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Omt ID Frame Panes NFRC Overhang U-Factl r SHGC Area Depth Separation Int Shade Screening 18 19 20 . 21 22 E 10 Vinyl Low-E Double Yes W 11 Vinyl Low-E Double Yes W 12 Vinyl Low-E Double Yes W 12 Vinyl Low-E Double Yes W 12 Vinyl Low-E Double Yes 0.3 0.25 21.3 ftz 20 ft 0 in 1 ft 0 in None 0.3 0.25 21.3 ftz 20 ft 0 in 1 ft 0 in None 0.32 0.22 48.6 ftz 6 It 3 in 1 ft 0 in None 0.32 0.22 6.7 ftz 6 ft 3 in 1 ft 0 in None 0.3 0.25 17.8 ftz 6 ft 3 in 1 ft 0 in None None None None None None INFILTRATION # Scope Method SLA CFM 50 I ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000318 3730 204.77 385.1 .2934 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Strip Heat None Electric Strip Heat None COP:1 34 kBtu/hr 1 COP:1 16 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype I Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit None Central Unit None SEER: 16 42 kBtu/hr 1260 cfm 0.75 1 SEER: 16 18 kBtulhr 540 cfm 0.75 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane None Main 0.59 4 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM i FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ftz DUCTS # — Supply — — Return — Air CFM 25 CFM25 Location R-Value Area Location Area Leaka a Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 450 ftz 2nd Floor Attic 6 150 ftz 2nd Floor 200 ftz Default Leakage 2nd Floor (Default) (Default) 10 ft' Default leakage 2nd Floor (Default) (Default) 1 1 2 2 12f20/2017 8:03 AM EnergyGauge® USA - FlaRes2014 Section R4d,5.4.1 Compliant Software Page 4 of 5 G(1RM PAnr,_7nl d TEMOPRATURES Programable�[ Ceiling Fans: I jThermosta�t: Heating [X} Jan ]FebY [X] Mar Apr WApr MayX] Jun rlJul May ]1 Aug rl $ep ri Oct J„1OOc Nov Nov Dec ]]Jan [[ ]] Feb X Mar Jun Jul Aug Sep tnl DecVenting[[ Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating(WEH) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 12120/2017 8:03 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFOR ANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 84 The lower the EnergyPerformancIe Index, the more efficient the home. 1316 Lone Pine DR, Fort Pierce, FL, 1. New construction or existing New (From Plans) 2. Single family or multiple family Single-family 3. Number of units, if multiple family 1 4. Number of Bedrooms 3 5. Is this a worst case? No 6. Conditioned floor area (ft2) 4476 7. Windows" Description Area a. U-Factor: Dbl, U=0.32 348.15 ft2 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.30 165.78 f12 SHGC: SHGC=0.25 c. U-Factor: Dbl, U=0.35 16.00 f12 SHGC: SHGC=0.24 d. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 7.145 ft. Area Weighted Average SHGC: 0.230 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 3101.00 ft2 b. Floor Over Other Space R=19.0 1375.00 ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy E Construction through the above energy saving features which in this home before final inspection. Otherwise, a new EPL D' based on installed Code compliant features. Builder Signature: Address of New Home: 9. Wall Types Insulation a. Concrete Block - Polystyrene Bead AggiR=4.0 b. Frame - Wood, Exterior R=19.0 c. N/A R=. d. N/A R= 10. Ceiling Types Insulation a. Roof Deck (Unvented) R=20.0 b. N/A R= c. N/A R= 11. Ducts a. Sup: Attic, Ret: 2nd Floor, AH: 2nd Floor b. Sup: Attic, Ret: 2nd Floor, AH: 2nd Floor Area 3125.00 ft2 1700.00 ft2 ft2 ft2 Area 3101.00 ft2 ft2 ft2 R ft2 6 450 6 150 12. Cooling systems kBtu/hr Efficiency a. Central Unit 42.0 SEER:16.00 b. Central Unit 18.0 SEER:16.00 13. Heating systems kBhdhr Efficiency a. Electric Strip Heat 34.0 COP:1.00 b. Electric Strip Heat 16.0 COP:1.00 14. Hot water systems a. Propane Cap: 40 gallons EF: 0.59 b. Conservation features None 15. Credits Pstat gncy Code for Building �TII� Sr11, gT be installed (or exceeded) ly Card will be completed 'wL GYP \ City/FL Zip: �. CpD we *Note: This is not a Building Energy Rating. If your Index is' below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building dode,• Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/20/2017 8:03 AM EnergyGauge® USA - FlaRes2014 - Sgction R405.4.1 Compliant Software Page 1 of 1