Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEc ?, 00 ® J Planning & D Building 2300 Virginia Avenue Certification for DE Project Name: STANDARD PACIFIC HOMES - R Project Address: 3046 NW RADCLIFFE WAY - Permit #: elopment. Services Department Code Regulations Division Fort Pierce, FL 34982 — (772) 462-1553 SCANNED ign Load Compliance [BY 'ERBEND St Lucia County 13 Occupancy�ype: -3 Construction Type: VB INSTRUCTIONS FOR USE: • This certification must be completed, signed, and si • Submit (2) copies for residential, (3) copies for com o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a buildir o Any non-residential structure. * Note: Form not required for interior renovations pro certain minor building permits at the discretion of the Ic DESIGN PARAMETERS AND ASSUMPTIONS USED: (cor 1. DESIGN CODE: Florida BUILDING CodIF 2. Structure Designed as (check one): X En 3. Risk Category: _I X II III I 4. Design Wind Velocity 170 mph 5. Mean Roof Height 30'-0" ft 6. Components & Cladding Design Pressures Us Zone 1: -39 Zone 2: -68 Zone 3:7. Design Loads: Floor: 40/25 PSF Roof/DDock: N/A PSF Deck: N/A PSF Stair8. Were Shear Walls Considered For Structure? led by the design professional of record. ercial with all permit applications involving the following: permit !d that no exterior structural elements are affected and building official. Contact the # above for questions. nplete all that apply) Edition with 20 14 Supplements using ASCE 7-10 Partially Enclosed Open Exposure Category: B X C D LRFD End Zone Width: 61-6" ft of Pitch: 4 :12 Parapet: N/A ft F, based on 10sgft @ 15'MRH, clearly label on all plan openings): 0 Zone 4: -46 Zone 5: -42 Garage: -44 15/10 PSF Roof/Live: 20/10 Balcony: 60130 PSF PSF Fence: N/A PSF Railings: PSF es Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes I Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF S it Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the uilding codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicte� on these plans provide adequate resistance to the design forcesspecifi��i��jlill//// 0 / VICTOR �HERNANIDEZ PE # 72387 CF• /� Print Name Cert # & Co. Cert Auth. BRENNAN ENGINEERING, INC. iigr% ; D �, Seal ; O'c � i ®.O DA Revised �4----G®'�.���\ 1600 S. Company DIXIE HWY STE 400 BOCA RATON & Address Dpy