Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEr EC��V L SCANNED aY DEC 0 5 2017 FORM R405-2014 at Lucia Count PER'dill'TING FLORIDA ENERGY EFFIC ENCr-CO ' VOW BUILDING CONSTRUCTION Florida Department of Business nd Professional Regulation - Residential Performance Method Project Name: TACOMA eARTISAN_MDW 170 Builder Name: GHO Homes Street: 9410 Pinebark CT. Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: GHO Homes Jurisdiction: Design Location: FL, ST LUCIE_CO_INTL County:: . St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (Fr m Plans) 9. Wall Types (2414.9 sqft.) Insulation Area 2. Single family.or multiple family Multi -fa ily a. Concrete. Block - Int Insul, Exterior R=4.1 2120.90 ft2 b. Frame - Steel, Adjacent R=11.0 294.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2726.9 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2522.00 ft2 6. Conditioned floor area above grade (ft2) 2522 b. Knee Wall (Vented) R=19.0 204.92 ftz Conditioned floor area below grade (ft2) 0 c. R= ft2 11. Ducts R ft2 7. Windows(421.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 504.2 a. U-Factor: Dbl, U=0.50 2 8.00 ft2 SHGC: SHGC=0.24 b. U-Factor: Dbl, U=0.53 6.00 ft2 12. Cooling systems kBtu/hr Efficiency - SHGC: SHGC=0.25 a. Central Unit 60.0 SEER:16.00 c. U-Factor: Dbl, U=0.46 5.83 ft2 SHGC: SHGC=0.26 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 1.92 ft2 a. Electric Strip Heat 60.0 COP:1.00 SHGC: other (see details) Area Weighted Average Overhang Depth: 183 ft. Area Weighted Average SHGC: 0. 43 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2522.0 sqft.) Insulation rea EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 252 .00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Pr4osed Modified Loads: 81.17 Glass/Floor Area: 0.167 PASS otal Baseline Loads: 81.64 I hereby certify that the plans and specifications cove ed by Review of the plans and FAKE STET this calculation are in compliance with the Florida rgy specifications covered by this 1, _ `-*0 Code. calculation indicates compliance with the Florida Energy Code. ti iirnr'�; ;;:•�`'^ „ O PREPARED BY: Ran McCracken Before construction is completed DATE: 11/15/2017 this building will be inspected for compliance with Section 553.908 Imp11iance I hereby certify that tl'iis 6U1din 's in c Florida Statutes. with the Florida Energy Code. OpWE :,asdesign OWNER/AGENT: BUILDING OFFICIAL: DATE: P Z DATE: r - Compliance requires certification by the air han ler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403..2.1. - Compliance requires an Air Barrier and Insulatio Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn rec)wres a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET. tandards, is not greater than 0.070 Qn for whole house. Pie CO 11/15/2017 9:54 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 5 1=01RM R4f15-gf114 PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: TACOMA_eARTISAN_MDW User GHO Homes 1 GHO Homes Multi -family New (From Plans) Bedrooms: 3 Conditioned Area: 2522 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address 9410 Pinebark CT. St. Lucie Fort Pierce , FL, 34951 CLIMATE Design Location TMY Site IECC Design Temp Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO 1NTL FL_VERO_BEAC MUNI 2 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2522 23538.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2522 23538.8 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Spac4 Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 242.75 ft 0 2522 ft2 ---- 0.8 0 0.2 ROOF # Type Materials Roof Gable Roof Area Area Color Solar SA Emitt Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Flat tile/slate 2821 ft2 0 ft2 Medium 0.75 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Ve �ted 150 2522 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 19 Batt 2522 ft2 0.11 204.92 ft2 0.11 Wood Wood 11/15/2017 9:54 AM EnergyG uge® USA - v5.1 - Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 WALLS Adjacent I Cavity Width Height Sheathing Framing Solar Below Space 1 S Exterior Concrete Block - Int Insul Main 4.1 13 6 9 4 126.0 ft2 0 0.600000 0 _ 2 SE Exterior Concrete Block - Int InslI l Main 4.1 3 9 4 28.0 ft2 0 0.600000 0 3 E Exterior Concrete Block - Int Ins I Main 4.1 2 6 9 4 23.3 ft2 0 0.600000 0 4 S Exterior Concrete Block - Int Ins I Main 4.1 7 9 12 4 95.6 ft2 0 0.600000 0 5 W Exterior Concrete Block - Int Insu++ Main 4.1 10 11 4 9.4 ft2 0 0.600000 0 6 SW Exterior Concrete Block - Int Insul Main 4.1 3 11 4 34.0 ft2 0 0.600000 0 7 S Exterior Concrete Block - Int Insull Main 4.1 9 11 11 4 112.4 ft2 0 0.600000 0 .8 S Garage Frame - Steel Main 11 24 4 9 4 227.1 ft2 0.23 0.01 0 .9 E Garage Frame - Steel Main 11 7 2 9 4 66.9 ft2 0.23 0.01 0 10 E Exterior Concrete Block - Int Insul Main 4.1 39 8 9 4 370.2 ft2 0 0.600000 0 11 N Exterior Concrete Block - Int Insul Main 4.1 27 11 4 306.0 ft2 0 0.600000 0 12 W Exterior Concrete Block - Int Insul Main 4.1 7 7 11 4 85.9 ft2 0 0.600000 0 13 NW Exterior Concrete Block - Int Insul Main 4.1 1 5 11 4 16.1 ft2 0 0.600000 0 14 N Exterior Concrete Block - Int Insul Main 4.1 13 3 11 4 150.2 ft2 0 0.600000 0 15 E Exterior Concrete Block - Int Insul Main 4.1 12 0 9 4 112.0 ft2 0 0.600000 0 16 N Exterior Concrete Block - Int Insul Main 4.1 16 9 4 149.3 ft2 0 0.600000 0 17 W Exterior Concrete Block - Int Insul Main 4.1 51 6 9 4 480.7 ft2 0 0.600000 0 18 NW Exterior Concrete Block - Int Insul Main 4.1 2 4 9 4 21.8 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area II Ft In Ft In 1 S Insulated ain None .14 3 8 24 ft2 2 S Wood tin None .14 2 8 8 21.3 ft2 3 N Insulated �ain ain None .14 1 2 8 9.3 ft2 4 E Insulated None .14 1 2.9 8 10 ft2 5 S Insulated Main None .14 3 8 24 ft2 WINDOWS Orientati n shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NF C U-Factor SHGC Area Depth Separation Int Shade Screening 1 S 1 Metal Low-E Double les 0.5 0.24 20.0 ft2 1 ft 0 in 1 ft 1 in Drapes/blinds Exterior 5 2 SE 2 Metal Low-E Double Yes 0.5 0.24 10.0 ft2 7 ft 11 in 7 ft 11 in Drapes/blinds Exterior 5 3 SE 2 Metal Low-E Double NZs 0.46 0.26 4.0 ft2 7 ft 11 in 0 ft 9 in Drapes/blinds Exterior 5 4 S 4 Metal Low-E Double Y'es 0.46 0.26 14.5 ft2 8 ft 6 in 4 ft 1 in Drapes/blinds Exterior 5 5 SW 6 Metal Low-E Double YI s 0.5 0.24 10.0 ft2 9 ft 4 in 7 ft 11 in Drapes/blinds Exterior 5 6 SW 6 Metal Low-E Double YLs 0.46 0.26 4.0 ft2 9 ft 4 in 5 ft 7 in Drapes/blinds Exterior 5 7 S 7 Metal Low-E Double Ygs 0.5 0.24 30.0 ft2 2 ft 0 in 3 ft 5 in Drapes/blinds Exterior 5 8 S 7 Metal Low-E Double Yes 0.46 0.26 12.0 ft2 2 ft 0 in 1 ft 8 in Drapes/blinds Exterior 5 9 E 10 Metal Low-E Double Yes 0.5 0.24 12.0 ft2 2 ft 0 in 1 ft 1 in Drapes/blinds Exterior 5 10 E 10 Metal Low-E Double Yes 0.5 0.24 40.0 ft2 2 ft 0 in 1 ft 1 in Drapes/blinds Exterior 5 11 N 11 Metal Low-E Double Yes 0.25 0.18 10.7 ft2 5 ft 4 in 3 ft 4 in Drapes/blinds Exterior 5 12 N 11 Metal Low-E Double Ye' 0.5 0.24 36.0 ft2 5 ft 4 in 3 ft 1 in Drapes/blinds Exterior 5 11/15/2017 9:54 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 3 of 5 "FORM R405-2014 Ori ntation WINDOWS shown is the entered, Proposed orientation. # Wall Ornt ID Frame Panes NFRC Overhang U-F actor SHGC Area Depth Separation Int Shade Screening 13 14 15 16 17 18 19 20 21 N 11 Metal W 12 Metal W 12 Metal N 14 Metal N 14 Metal E 15 Metal N 16 Metal W 17 Metal W 17 Metal Low-E Double Low-E Double Low-E Double Low-E Double Low-E Double Low-E Double Low-E Double Low-E Double Low-E Double Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.46 0.26 8.0 ft2 5 ft 4 in Oft 11 in 0.5 0.24 24.0 ft2 17 ft 0 in 3 ft 7 in 0.46 0.26 5.3 ft2 17 ft 0 in 1 ft 5 in 0.53 0.25 96.0 ft2 14 ft 4 in 3 ft 1 in 0.46 0.26 16.0 ft2 14 ft 4 in 0 ft 11 in 0.25 0.18 11.2 ft2 32 it 8 in 3 ft 4 in 0.5 0.24 40.0 ft2 2 It 0 in 1 ft 1 in 0.5 0.24 6.0 ft2 2 ft 0 in 1 ft2 in 0.46 0.26 12.0 ft2 2 It 0 in 1 ft 0 in Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Exterior 5 Exterior 5 Exterior 5 Exterior 5 Exterior 5 Exterior 5 Exterior 5 Exterior 5 Exterior 5 GARAGE # Floor Area Ceiling A ea Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 688.988895 ft2 688.988845 ft2 77.5 ft 9.33 ft 0 INFILTRATION �# Scope Method S CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000415 2746.2 150.76 283.53 .3113 7 HEATING SYSTEM # System Type Subt pe Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 60 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subty�e Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 60 kBtu/hr 1800 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Loc tion EF Cap Use SetPnt Conservation 1 Electric None Gar ge 0.95 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 11/15/2017 9:54 AM EnergyGaugeo USA - v5.1 -Section R405.4.1 Compliant Software Page 4 of 5 'RnRM R4n5-91114 DUCTS ---- Supply --- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 504.2 ft Attic 126.05 Proposed Qn Main --- cfm 176.5 cfm 0.07 0.60 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: N CoolingJan HeatinJan Feb Feb Mar Mar f r Apr f Ma May f Jun Jul Jun IXjJul AuSeP rj Au Se rl W Oct Oct Nov Nov Dec Dec Ventin Jan Feb X Mar [X] r [ Ma [ Jun Jul Aug Se Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 11/15/2017 9:54 AM EnergypaugeO USA - v5.1 - Section R405.4.1 Compliant Software Page 5 of 5 a FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED NERGY PERFORMANCE INDEX* = 99 The lower the E lergyPerformance Index, the more efficient the home. 941 Pinebark CT., Fort Pierce, FL, 34951 1. New construction or existing New 1 2. Single family or multiple family Multi- 3. Number of units, if multiple family 1 4. Number of Bedrooms 3 5. Is this a worst case? No 6. Conditioned floor area (ft2) 2522 7. Windows" Description a. U-Factor: Dbl, U=0.50 SHGC: SHGC=0.24 b. U-Factor: Dbl, U=0.53 SHGC: SHGC=0.25 ' c. U-Factor: Dbl, U=0.46 SHGC: SHGC=0.26 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. N/A R= c. N/A R= I certify that this home has complied Construction through the above enei in this home before final inspection. based on installed Code compliant f Builder Signature: Address of New Home: yy0 om Plans) 9. Wall Types Insulation Area nily a. Concrete Block - Int Insul, Exterior R=4.1 2120.90 ft2 b. Frame - Steel, Adjacent R=11.0 294.00 ft2 c. N/A R= ft2 d. N/A R= ft2 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 2522.00 ft2 b. Knee Wall (Vented) R=19.0 204.92 ft2. c. N/A R= ft2 Area 11. Ducts R ft2 228.00Area ft2 a. Sup: Attic, Ret: Attic, AH: Main 6 504.2 96.00 ft2 12. Cooling systems kBtu/hr Efficiency 75.83 ft2 a. Central Unit 60.0 SEER:16.00 21.92 ft2 13. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 60.0 COP:1.00 8.183 ft. 0.243 Area 14. Hot water systems a. Electric Cap: 50 gallons 2522.00 ft2 EF: 0.95 ft2 b. Conservation features ft2 None 15. Credits Pstat the florida Energy Efficiency Code for Building 3vinp features which will be installed (or exceeded) :rwi e, a new EPL Display Card will be completed *Note: This is not a Building Energy RE mortgage (EEM) incentives if you obtain 638-1492 or see the EnergyGauge web information about the Florida Building C staff. **Label required by Section R303.1.3 nn�� Date: Z, c �7CJe/� - 04 City/FL Zip: C :ing. If your Index is below 70, your home may qualify for energy efficient a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) Site at energygauge.com for information and a list of certified Raters. For ide, Energy Conservation, contact the Florida Building Commission's support Florida Building Code, Energy Conservation, if not DEFAULT. 11/15/2017 9:54 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1