Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION
Building Analysi Entire House SCANNED) .. BY For: GHO Homes 9410 Pinebark Ct, Ft Location: St Lucie Co Intl, FL, US Elevation: 26 ft Latitude: 28°N Outdoor: Heating Dry bulb (°F) 41 Daily range °F) - Wet - Wind speed mph) 15.0 DEC 0 5 2017 PEWAIITIPIC-3 St. Lucie County, FL FL 34951 Job: Tacoma Lot 170 Date: 11-13-17 By: Skyetec Indoor: Heating Cooling Indoor temperature (°F) 70 75 Design TD (°F) 29 15 Relative humidity (%) 50 50 Cooling Moisture difference (gr/lb) 24.4 56.9 90 Infiltration: 15 ( L ) Method Simplified 77 Construction quality Average 7.5 Fireplaces 0 Component Btuh/ tz Btuh % of load Walls 4.1 7974 18.4 ,Glazing 14.4 6199 14.3 Doors 11.3 1025 2.4 Ceilings 0.9 2311 5.3 Floors 2.9 7306 16.9 Infiltration 2.0 4408 10.2 Ducts 10541 24.3 Piping 0 0 Humidification 0 0 Ventilation 3538 8.2 Adjustments 0 Total 1 1433021 100.0 Component Btuh/ftz Btuh % of load Walls 2.5 4924 13.0 Glazing 13.7 5856 15.5 Doors 11.4 1036 2.7 Ceilings 1.0 2614 6.9 Floors 0 0 0 Infiltration 0.5 1170 3.1 Ducts 12857 34.0 Ventilation 1879 5.0 Internal gains 7470 19.8 Blower 0 0 Adjustments 0 Total 37807 100.0 Latent Cooling Load = 12622 Btuh Overall U-value = 0.115 Btuh/ftz-°F Data entries checked. COPS' - Z_ + wrightsoft- Right -Suite® Universal 2017 17.0.04 RS000269 .4 ..oad CalculationslSkytec\Tacoma Lot 170 GL S.rup Calc = MJ8 Front Door faces: S 2017-Nov-13 16:11:30 Page 1 Component Co Entire House ructions Job: Tacoma Lot 170 Date: 11-13-17 By: Skyetec For: GHO Homes 9410 Pinebark Ct, Ft. Pie ce, FL 34951 Location: Indoor: Heating Cooling St Lucie Co Intl, FL, US Indoor temperature (OF) 70 75 Elevation: 26 ft Design TD (OF) 29 15 Latitude: 280N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 24.4 56.9 Dry bulb (OF) 41 90 Infiltration: Daily range (OF) - 15 ( L ) Method Simplified Wet bulb (F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Walls 13A-4ocs: Blk wall, stucco ext, r-4 ext bd ins, 8" thk, 1/2" gypsum board int fnsh Partitions 128-0sm: Frm wall, stucco ext, r-11 cav ins, 1/2" gypsum board int fnsh, 2"x4" metal frm, 16" o.c. stud 12C-Osw: Frm wall, stucco ext, r-13 cav ins, 2"x4" wood frm, 16" ox stud r Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/t? °F ft? °F/Btuh MOM' Btu Btuh/ft' Btu n 378 0.143 4.0 4.15 1566 2.59 978 n 40 0.143 4.0 4.15 167 2.59 104 e 431 0.143 4.0 4.15 1785 2.59 1114 se 11 0.143 4.0 4.15 47 2.59 29 s 238 0.143 4.0 4.15 987 2.59 616 sw 17 0.143 4.0 4.15 70 2.59 44 w 560 0.143 4.0 4.15 2321 2.59 1448 nw 24 0.143 4.0 4.15 100 2.59 63 all 1698 0.143 4.0 4.15 7043 2.59 4396 Windows 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" n thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 6 ft overhang (1.6 ft window ht, 1 ft sep.); 6.67 ft n head ht all 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" n thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 15 ft overhang (1.6 ft window ht, 1 ft sep.); 6.67 ft head ht 2 glazing, cir low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" n thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 it overhang (3 ft window ht, 1 ft sep.); 6.67 ft head ht 256 0.122 11.0 3.54 906 2.01 515 9 0.091 13.0 2.64 25 1.31 12 5 0.460 0 13.3 62 10.1 47 5 0.460 0 13.3 66 10.1 50 10 0.460 0 13.3 128 10.1 97 19 0.460 0 13.3 256 10.1 194 3 0.460 0 13.3 37 10.1 28 wrightsoft, Right -Suite® Universal 2017 17.0.04 RS000269 I 2017-Nov-13 1Page 1 1 wit Page ...oad CalculationslSkyteclTacoma Lot 170 GL S.rup Calc = MJ8 Front Door faces; S 2 argon clr low-e outr, on gas, vnl frm mat, cir innr, 1/4" gap, I /4" glazing, 9 n thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" g p, W" thk; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50 0 outdoor insect screen; 1.5 ft overhang (5 ft window ht, 1 ft sep.); 6. 7 ft e head ht all glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1,4" n thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; 6 ft overhang (6 ft window ht, 3 ft sep.); 6.67 s head ht all 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" n thk: 2 glazing, clr low-e outr, argon gas, vnl firm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% blinds 45°, medium; 50% outdoor insect screen; 15 ft overhang (8 ft window ht, 3 ft sep.); 6.67 ft head ht I 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4' e thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 3 ft overhang (5 ft window ht, 1 ft sep.); 6.67 ft head ht 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" e thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (3 ft window ht, 1 ft sep.); 6.67 ft head ht w all 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" se thk: 2 glazing, clr low-e outr, argon. gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% sw outdoor insect screen; 1.5 ft overhang (2 ft window ht, 1 ft sep.); 6.67 ft head ht w all 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" se thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45', medium; 50% s outdoor insect screen; 1.5 ft overhang (6 ft window ht, 1 ft sep.); 6.67 ft head ht sw all 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 6 ft overhang (2 ft window ht, 1 ft sep.); 6.67 ft head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" s thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 114" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 10 ft overhang (2 ft window ht, 3 ft sep.); 6.67 ft head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" s thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 10 ft overhang (8 ft window ht, 3 ft sep.); 6.67 ft head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" w thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 7.5 ft overhang (1.6 ft window ht, 1 ft sep.); 6.67 ft head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" w thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; 7.5 ft overhang (6 ft window ht, 3 ft sep.); 6.67 ft head ht Doors 11DO: Door, wd sc type n e s n all '&* wrights®ft® Right -Suite® Universal 2017 17.0.04 RS000269 ...oad CalculationslSkyteclTacoma Lot 1170 GL S.rup Calc = MJ8 Front Door 40 0.500 0 14.5 580 10.4 415 40 0.500 0 14.5 580 24.3 972 80 0.500 0 14.5 1160 17.3 1387 37 0.500 0 14.5 537 10.4 384 36 0.500 0 14.5 522 10.4 373 73 0.500 0 14.5 1059 10.4 757 96 0.530 0 15.4 1476 10.9 1049 5 0.460 0 13.3 67 21.2 106 12 0.500 0 14.5 174 23.8 286 6 0.500 0 14.5 91 23.8 149 18 0.500 0 14.5 265 23.8 435 4 0.460 0 13.3 51 13.0 50 4 0.460 0 13.3 51 13.0 50 12 0.460 0 13.3 162 24.0 292 20 0.460 0 13.3 265 19.8 392 12 0.500 0 14.5 167 17.6 202 24 0.500 0 14.5 348 10.4 249 12 0.500 0 14.5 167 17.6 202 47 0.500 0 14.5 682 13.9 653 12 0.460 0 13.3 160 10.1 121 8 0.460 0 13.3 107 10.1 81 8 0.460 0 13.3 107 10.1 81 6 0.460 0 13.3 85 10.1 65 24 0.500 0 14.5 348 17.1 412 23 0.390 0 11.3 256 11.4 259 23 0.390 0 11.3 256 11.4 259 24 0.390 0 11.3 271 11.4 274 21 0.390 0 11.3 241 11.4 244 91 0.390 0 11.3 1025 11.4 1036 S 2017-Nov-13 16:11:31 Page 2 Ceilings 16D-30td: Attic ceiling, tile, slate, concrete roof mat, r-30 ceil ins, /2' gypsum board int fnsh Floors 22A-cpm: Bg floor, heavy dry or light damp soil, on grade depth, car fir fnsh I 22A-tpm: Bg floor, heavy dry or light damp soil, on grade depth, tile fir fnsh ,� + wrightsoft® Right -Suite® Universal 2017 17.0.04 RS000269 AM ...oad CalculationsMytec\Tacoma Lot 170 GL S.rup Calc = MJ8 Front Door 2491 0.032 30.0 0.93 2311 1.05 2614 71 1.180 0 34.2 2444 0 0 142 1.180 0 34.2 4862 0 0 2017-Nov-13 16:11:31 S Page 3 Project Summa Entire House For: GHO Homes 9410 Pinebark Ct, Ft. Notes: Weather: St Winter Design Conditions Outside db 41 OF Inside db 70 OF Design TD -29 OF Heating Summary Structure 32761 Btuh Ducts 10541 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 43302 Btuh Job: Tacoma Lot 170 Date: 11.13-17 By: Skyetec Pierce, FL 34951 Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Cooling Area (ft2)2491 2491 Volume (ft3) 25931 25931 Air changes/hour 0.32 0.16 Equiv. AVF (cfm) 138 69 Heating Equipment Summary Make Trade Model AHRI ref Efficiency 100 EFF Heating input 12.3 kW Heating output 41975 Btuh Temperature rise 20 OF Actual air flow 1933 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Space thermostat Calculations approved by ACCA to i Co Intl, FL, US Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 57 gr/lb Sensible Cooling Equipment Load Sizing Structure 24949 Btuh Ducts 12857 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 36067 Btuh Latent Cooling Equipment Load Sizing Structure 8761 Btuh Ducts 3860 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 12622 Btuh Equipment total load 48689 Btuh Req. total capacity at 0.80 SHR 3.8 ton Cooling Equipment Summary Make Rheem Trade RHEEM; RUUD Cond RA1660AJ1 Coil RH1T6024STAN AHRI ref 7943714 Efficiency 13.0 EER, 16 SEER Sensible cooling 46400 Btuh Latent cooling 11600 Btuh Total cooling 58000 Btuh Actual air flow 1933 cfm Air flow factor 0.051 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.75 all requirements of Manual J 8th Ed. wrightsoft® 2017-Nov-1316:11:31 �� Right -Suite® Universal 2017 17.0.04 RSU00269 I Page 1 ..oad Calculations\Skytec\Tacoma Lot 170 GL S.rup Calc = MJ8 Front Door faces: S II Master Suite 131 cfm 10 x 10 \131 cfm 8",13.7ft ,10x10 His 1 fM- �a� Tacoma F 12 x 12 Ba 3 Nook _ 8 x 8 10",3.6ft 50cfm cfm /6 ", 12.2 ft 208 + 12 x 12 T 12 x 12 10 ", 6.5 ft ( Bedroom 3 8",11.1ft 35 \ ccffm m /6x6 4 cfm Great Rm g ", 10.0 it 4",1.8ft 18",32.3ft lox 10 14 cfm 6x6' �6",5.1f':� 26cfm y�8x8 4 ", 5.5 ft 77 cfm Aaster Bath 14 x 14 VF 12",9.4ft 8x8� 14 x 14 56 cfm y 6",6.5ft { y 12 x 12 167 cfm Den 9 ", 18.6 ft ftFFooyer I \ 10x10 12 x 12 153 cfm 223 cfm 14 ",. 2.5 ft 9",8.7ft 8" 6.1 ft Kichen 8 ", 5.9 ft 10 x 10 �162 cfm I (� 18 ", 11.5 ft Bedroom 2 30x18\ 14",23.7ft 12x12 I107 cfm 6 x 6 Hal 10",4.5ft y I10x10 53cfm\ 5",7.4ft Ufui B�49ft.4",3.6ft O Bath 188.4ft O 12x12 F I—< Dining 6 x 6 ft 418 ", 7.4 8 cfm 20 ", 9.6 ft ; \6x6 14".4.2ft 23 cfm Schedule Exhaust Fan F Range Vent Dryer Vent O Rheem EquipmentARI 7943714 5.0 Ton 16 SEER RH1T60 AHU 5.0 Ton 16 SEER RA1660 Cond Job #: Tacoma Lot 170 Performed by Skyetec for: GHO Homes 9410 Pinebark Ct Ft. Pierce, FL 34951 Garage C� , Scale: 1 : 115 Page 1 Right -Suite® Universal 2017 17.0.04 RS000269 2017-Nov-13 16:11:35 ...s\Skytec\Tacoma Lot170 GLS.rup I Duct System Summary Job: Tacoma Lot 170 Date: 11-13-17 Entire House I By: Skyetec For: GHO Homes 9410 Pinebark Ct, Ft. Pierce, FL 34951 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0.18 in H2O 0.32 in H2O 0.215 0.105 in H2O I0.090 in/100ft 1933 cfm Cooling 0.50 in H2O 0.18 in H2O 0.32 in H2O 0.215 / 0.105 in H2O 0.090 in/100ft 1933 cfm 355 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath 2 h 1377 61 48 0.1i53 5.0 Ox 0 VIFx 14.8 125.0 st2 Bath 3 h 2040 91 50 0.096 6.0 Ox 0 VIFx 43.6 180.0 st5 Bedroom c 3164 125 162 0.126 8.0 Ox0 VIFx 24.9 145.0 st4 Bedroom c 2998 117 153 0.161 8.0 Ox0 VIFx 37.6 175.0 st5 Den h 5133 229 167 0.169 9.0 Ox0 VIFx 36.9 160.0 st1 Dining h 3413 152 107 0.12,4 8.0 OxO VIFx 23.3 150.0 st1 Foyer h 1773 79 56 0.123 6.0 Ox 0 VIFx 24.9 150.0 st1 Great Rm c 2832 117 145 0.123 8.0 Ox 0 VIFx 28.9 145.0 st4 Great Rm-A c 2832 117 145 0.099 8.0 Ox 0 VIFx 42.5 175.0 st5 Hers c 83 3 4 0.096 4.0 Ox0 VIFx 43.9 180.0 st3 His h 1167 52 24 0.093, 4.0 Ox 0 VIFx 49.7 180.0 st3 Kitchen c 4367 43 223 0.12 9.0 Ox 0 VIFx 27.7 145.0 st4 MECH-A h 770 34 23 0.196 4.0 Ox0 VIFx 4.2 105.0 Master Bath h 1816 81 77 0.094 6.0 Ox 0 VIFx 47.2 180.0 st3 Master suite -A h 3717 166 131 0.091 8.0 Ox 0 VIFx 55.7 180.0 st3 Master Suite-B h 3717 166 131 0.090 8.0 Ox 0 VIFx 53.3 185.0 st3 Nook h 5826 260 208 0.101 10.0 Ox 0 VIFx 37.9 175.0 st5 Utility c 1036 14 53 0.158 4.0 Ox 0 VIFx 11.0 125.0 st2 WC c 506 24 26 0.094 4.0 I Ox0 VIFx 47.5 180.0 st3 Bold/italic values have been manually overridden AC= + wrightsoft® Right -Suite® Universal 2017 17.0.04 RS000269 I 2017-Nov-13 16:11:31 Page 1 ...oad Calculations\Skytec%Tacoma Lot 170 GL S.rup Calc = MJ8 Front Door faces; S Trunk Htg Clg DesFF gn Veloc Diam H x W Duct Name Type (cfm) (cfm) (fpm) (in) (in) Material Trunk st5 Peak AVF 585 556 548 14.0 0 x 0 VinlFlk st4 st3 Peak AVF 492 393 N96 0. 90 460 14.0 0 x 0 VinlFlx st1 st1 Peak AVF 953 724 0.090 539 18.0 0 x 0 VinlFlx st4 Peak AVF 870 1086 O.g96 615 1&0 0 x 0 VinlAx st2 st2 Peak AVF 946 1187 0.096 1 672 1&0 0 x 0 VinlFlx Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) . - FI - (fpm) (in) (in) Opening (in) Matl Trunk rb4 Ox0 1933 1933 117.1 0 90 1094 1&0 0x 0 VIFx rst3 Trunk Htg Cig Desig Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk rst3 Peak AVF 1933 1933 0.0910 886 20.0 0 x 0 VinlFlx