HomeMy WebLinkAboutGENERATOR05 Ui I.._, cIns, � 1 S WYE® GUARDIAN® SERIES cr /2, 0 / 2 � Sty. de ftnlffesidential Standby Generators Air -Cooled Gas Engine I INCLUDES: True Power'M Electrical Technology ® Two Line LCD Multilingual Digital Evolution' Controller (English/Spanish/ French/Portuguese) ® Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. • Electronic Governor e System Status & Maintenance Interval LED Indicators I Standby Power Rating Models G007036-0, G007037-0 (Aluminum - Bisque) -16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) -16 kW 60 Hz Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-1, G007042-1 (Aluminum - Bisque) - 22 kW 60 Hz i i�ENERAG 0 Sound Attenuated Enclosure 0 Flexible Fuel Line Connector • Direct -To -Dirt Composite Mounting Pad e Natural Gas or LP Gas Operation C@US QVI s 5 Year Limited WarrantyLISTED i Note: CUL certification only applies to unbundled units and units packaged with :CUL limited circuit switches. Units packaged with the Smart Switch are UL certified In • Capability to be installed within 18" (457 mm) the USA only. of a building* I `Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. I FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: success in providing the most reliable generators possible. Generac's G-Force engine This state-of-the-art power maximizing regulation system is standard on lineup offers added peace of mind and reliability for when you need it the most. The all Generac models. It provides optimized FAST RESPONSE to changing G-Force series engines are purpose built and designed to handle the rigors of load conditions and MAXIMUM MOTOR STARTING CAPABILITY by extended run times in high temperatures and extreme operating conditions. electronically torque -matching the surge loads to the engine. Digital o � O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5%Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. O TEST CRITERIA: N/ PROTOTYPE TESTED J NEMA MG1-22 EVALUATION V SYSTEM TORSIONAL TESTED V MOTOR STARTING ABILITY voltage regulation at _0,b. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. GENERAC Nat' -ass ,y4y, _ � E °c®e• �`©?� Mobile® � t I— PROMISE Link n. a��AIER GP $,9RRA� •8u/H In ltro USA u�ing dameslle anO! Ign paNs 16/20/22 kW GENERAC° features and benefits Engine • Generac G-Force design Maximizes engine "breathing" for Increased fuel efficiency. Plateau honed cyl I nd er wal Is and plasma moly rings helps the engine run cooler, reducind*6il'cb sumptioii""resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ing up, to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) , • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution'" Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. Installation System • 1 It (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. 0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. , RA 16/20/22 W specifications Generalor G007035-0, G007036-0, G007038-0, G007039-0 6007042-1, G007043-1 Model G007037-0 (16 kW) (20 I(W) (22 kW) Rated°Maxlmom Continuous Rawer Gapactty.(LP} : r : I 16,000.Watts M000 =s' • 22,000 . Rated Maximum Continuous Power Capacity (NG) ; 16,000 Watts' 18,000 Watts' 19,500 r Rated'Voliage :...:..._.[cY_:.7_.. Q 240. __,.... ---- Rated Maximum nuous Load Current 240 Volts (LP/NG) Contl _,. _ .."�'�.'22 66.6/66.6 83.3/75 91 6/81 3 Total Harmonic Dtstortton .' . ' = Less than 54° - Less thag546 ... - Less than 5°% Main Line Circuit Breaker - 70 Amp ^ - - _- - `- 100 Amp 100 Amp _ Number of Rotor Poles 2 2 2 •���fiOHz:•:,:�.,w. : --— - ~ �fiOHz•.: _ 6 0Hz : Power Factor 1.0 _r - - 1.0 - _ .' 1.0 Batt ry gwremenC(not Included) _ -, _, ": __^_ y 12 Volts `Group 26R�540.CCA�Mimmum or Group 35m 650 CCA,Muilmum _ _^— Unit Weight (lb/kg) /zk y 406/186 448/203 466/211 Wg) °Dlmenslons x H) iNmm z 2%x73 .4 --- Sound output in dB(A) at 23 ft (7 ri with generator operating at normal load"' 66 66 67 Sound.oirtp in dB(A) at 23 ft.(7 m) with generator iri Quiet Test'•": low speed ezercise'mode. - 58.`='- � "} - "'58 - 58 Exercise duration 5 min 5 min 5 min Engine Type of Engine GENERAC G-Force 1000 Series Nlrmbei of Cylinders .. �:.- .:: • .. • _ .- - 1' _ - . 2 ; , -: - • . - %2, - ., _-.___ __ , .. .._ _ z - Displacement 999 cc 999 ec _ 999 cc :Cylinder Block _ Alurminiim w/;Cast Iron Sleeve '- - - Valve Arrangement - Overhead Valve Overhead Valve Overhead Valve :IgnitiomSystem - :__• ...: :... i - Solid-statew%Magnets . Solid-statew�Magneto.- -'_: Solid-state.w/Magrieto - - -- _. _ - - - - Governor System I ---- - Electronic . _ ._.__.--- ----- . Electronic Electronic --951 Staffer 12 Vdc 12 Vdc 12 Vdc - - = " : •'` ' � . Oii Capacity lncludmg Filter 9 gU.1;8_L' w �Approx. l�9Tg111.6Apprrixi l:9;gU1.8 L; . _ .. Operating rpm _AK(0Qj 3,600 rv^ 3,600 3100 FueiConsurnptron I ` Natiiral:Gas'' ftamr(rri3/hr).•,. 4 1/2 Load', r., .. _ _ :..:'_,.. is ,•'' _ ` T218.(6.17j;-T.' .+._:.•...._ 20d(5.78) ,,, .. _ .228 (6A6j Full Load M-: •• �. 309 (8_,75) -•301 (8.5,2) 327 (9.26) Liquid Propane H3/hr (gal/hr) [Vhr] , ; 91.6,(2_52) [9.53i_ , 99] 92 (2.53) [9.57] :: _ - Full Loads `r - .'• 106 8 (2a94) [1111]vr129:6r�9 .:,86'(2.37).18 b6)`[13'48] 142 (3 90) [1477] ' _ �; Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7' water column (7-13 min mercury) for natural gas,10-12' water column (19-22 min mercury) for LP gas. For Btu content, multiply fl3/hr x 2500 (LP) or ft3/hr x 1000 (NG). For Megajoule content, multiply ma/hr x 93.15 (LP) or ma/hr x 37.26 (NG) Controls I 2-Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. Automatic Stint art lltl'ily failure: 7 daday exerciser: Manual Start with starter cont ol, unit stays on. If utility fads, transfer to load takes place. 7,_:.Stops unit: Power-I—r •s r, _emoved;.Control apd cliargerstilloperate. Ready to Run/Maintenance Messages Standard Engmo Aun Houfs indisatioo _ -' . : Stapda�d , _ Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) UblrtyVoltageEoss/Return oUhlrtyAdjustahle.(BrowpoulSettipgp, ®ram 14b-171 V/190.216 V Future Set Capable Exerciser/Exercise Set Error Warning Standard -"�'-`-"-"- -` ` NAlarm�M�amtfen�c..Logs - : = ..._.. 50 Events Each' Engine Start Sequence Cyclic cranking 16 sec on, 7 rest (90 sec maximum duration) j;SharterLock-0u(' { ; _ _ ! ,,:, - - - � - .• Starter cannof re engage unhl 5 sec after engine has stopped_.. ._ ,_r - Smart Battery Charger Standard hargersFaglUMlsstng;ACWarnin9 Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard I'Au[omahc Voltage Regulation with Overand Under,Voltage Fiolechon - _ _ _ _. • . • � � � Standard':'. µ •- Under-Frequency/Overload/Stepper Overcurrenl Protection Standard :Safely Ftjsed/Fuse Problem Protectlati "• = Standard _ Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard ---- jOVercranWOVerspeetl(@72Hz)/rpm Sense LossShbtde - Standard • ., . .. :. . High Engine Temperature Shutdown - --_. ....... Standard internal:Foull_UlncorrectWinrtg°Pr`otection „`.. -_ Standard ......__.._......._._.__.__._ _..----.::.._-- -- _. Common External Fault Capability Standard --.. -- - - `FteldUpgradableFirmYiare ___ ._.._.._._._. ;,- ..;,---- --... _. __ , . -. •. , Standard;"..:' � . —Sound levels are taken from the front of the generator. Sound levels taken from othersides of the generator maybe higher depending on installation parameters. Rating definitions -Standby Applicable forsuppifingemergencypowerfortheduration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, IS03046 and.DIN6271). ' Maximum kilovolt amps and current are subject to and limited by such factors as fuel Blu/megaloule content, ambient temperature, altitude, engine powarand condition, etc. Maximum power decreases about 3.5 percent foreach 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent foreach 6 °C (10'F) above 16 °C (60 °F). 16/20/22 W switch options Limited Circuits Switch Features • 16 space, 24 circuit, breakers not included. • Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductor's. • Main contacts are silver plated or silver alloy to,resist welding and sticking. • NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive install. Dimensions Height Width Depth H1 H2 Wi W2 in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 Wire flanges Conductor Lug Neutral Lug Ground Lug 1/0-#14 2/0-#14 2/0-#14 bervice mated amart biwi mn Features • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioneri.loads with no additional hardware. ' • Up to four more large (240 VAC) loads -can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load, IGO% equipmentirated, both inductive and resis- tive. i • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions 200 Amps 120/240, is Open Transition Service Rated Height Width H1 H2 W1 W2 Depth in 1 26.75 30.1 10.5 13.5 6.91 mm 1 679.4 764.3 266.7 343.0 175.4 Model G007036.0 (16kW) Current Rating (Amps) ion VoltagRating{VAC)'` �` 120/P40`1A ai Utility Voltage Monitor (Fixed)* -Plck-op 80% -Dropout 65% sRelum la Uhh '"- Exercises bi-weekly for 5 minutes*t Standard 11LLfsted ` —,_..�., k x .. Total Circuits Available 24 Tan"deml3reakerCapabrlihes+ _ ' s'> de Circuit2 Circuit Breaker Protected . Available RMS Symmetrical 10,000 Fault Current @ 250 Volts *Function of Evolution Controller Exercise can be set to weekly or monthly wt — DEPTH I w2 — Model G007037-0 (16 kM/GO07039-0 (20 kW)/ G007043-0 (22 kW) No. of Poles - 2 Current Rating (Amps) 200 Voltage Rating NAC) J" r 120/240;,1A �U ' Utility Voltage Monitor (Fixed)* _... _._._..,.. _- -Pick-up 80% -Dropout 65% Aetum tox,Ulility� '� _ _ ''-" {apprax 13 sec �n �r Exercises hi -weekly for 5 minutes* Standard Enclosure Type NEMA/UL 3_R Lug Range 250 MCM - #6 *Function of Evolution Controller Exercise can be set to weekly or monthly wi 7- . {i. aw1 H4'.-......� H7 DEPTH W, 16/20/22 kW GENERAL available accessories I?raduc4 - - - —^- - -_..._ bescrrpttdri- - -------------- ......---._.._.. ___._.:...___._�_...._.._.._ The Wi-Fi- enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon-,! itoring the LP tank's fuel level is an important step in making sure your generator is ready to run during an G007005-0 WI-Fi LP Fuel Level Monitor unexpected powerfailure. Status alerts are available through a free application to notify when your LP tank: is in need of a refill. Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac-' G006463-4 Mobile Link," cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or: text message when a change In the generator's status occurs. Available in the U.S, only. Every standby generator requires a batteryto startthe system. Generac offers the recommended 26R wet G005819-0 26R Wet Cell Battery cell battery for use with all air-cooled standby product (excluding PowerPact@) M ` 'The pad warmer rests underthe battery. Recommended for use if the temperature regularly falls below OOF., G007101-OvI��TBattery Pad Warmer (Nat necessary for use with AGM -style batteries). 'Oil Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below G007102-0 Warmer o F. 'Auxiliary Transfer Switch : The auxiliary transfer switch contact kit allows the transfer switch to lack out a single large electrical load G005621-0 Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. :The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G007027-0 - Bisque Fascia Base Wrap Kit sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting. (Standard on 22 kW) ;holes located in the base. :If the generator enclosure is scratched or damaged, it is important to touch-up the paintto protect from G005703-0 - Bisque Paint Kit future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine `Smart maintenance on a Generac automatic standby generator. G006873-0 Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its power management capabilities. It provides additional power management f lexibility not found in any other (50 Amps) _ power management system. - LEF MBE VIEW dimensions & -UPCs Dimensions shown are approximate. Refer to Installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. i I FROWMEW Model UPC G007035-0 696471070354 G007036-0 696471070361 0007037-0 696471070378 G007038-0 696471070385 G007039-0 696471070392 G007042-0 696471070422 0007043-0 696471070439 G E I E RAC® Generac Power Systems, Inc, o S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com 02017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. 10000000194-F 5/3/17 GEHERACO ACCESSORIES Model 0006873tl0 USM Ge terac's Smart Power Management System is designed to optimize the performance of a standby generator. The system c Smart and operate egt Modules {5MM). tlnl(ke other load management systems that depend on another control device, be SMM modules am actually self- awateand operate autanornously. Y an consist of up to 8 lrtrllvidual Y Frequency is the true measure of generator engine performance and generator fuel type. The modules m0nl does not need to taolor in Increased ambient temperatures, elevation changes or threshold, the module will automaticatty t fhe i a PuBncy (Hz) of the Polver being produced by Generac's standby generators and it it falls below a certain ollov�a power management algotifhrrl to eltsure that the generator )snot overloaded. The modules can be set to a road priority betwelen 1-8 or be set in a lookout 0nl}'mode for toads that just simply do not need to run to an outage, reducing the necessary size of the generator for a more cost effective soldnon. , thetatore f re SUM 8PEC1F1CA''10A48 FawarPowerSupply Source...,....°., rled Voltages.......................................................w................................................................. COnlaoror l:olf Voltage................................. ......................................... _.........._..... ............................. 294 VAC (from Line Input) CoilelorCallvolegeush .°.....°........................................_.....................,......,......,....,..........°°°°.°....._...,.,.,.......,............,................................................—.240VAC CollVA Seated ............... ...........,,......,..............,......,.............._..........._..............................................................°...°..........,...........................,.............,...........,240 VAC Poles................................... .............................°..........................°....°.°..°,...°........................................ �.... ........,.....,..,....,.........,..................°,.,.°.................°°_.................I o ResislIMAmps........................ ................... ..,...............................,.............................................,.............,s2 KladuoUvaAmps.........°...................°..°..°...°°...°°.........................................,........................................... ,........ LookedRotorAmps........................°....°°..............°.....................................................................................,., . ,.............. . ...........,....,.,..........° ..........°..,........30 EnclosureRating ..... .................................. ............... .............. °....................... ........... ..............,...._.....,.....................,..................................290@290V ...........Yes _........... .......................... .................................. ....................NENIA SR l' SIte Selegfion and Preparation CA Reparation �a Selection and Site Selection O 5 L ('l.s2 mj O S it (1,62 m) r � I r a � r A 3 it (0.91 m) mgUre a-9, lias>:alJa on +Cle Mn'Cas to Description Comments A 'fop or -generator — 8 Front and end eleamnee fAimum cleardlstances cannot Include shrubs, bushes, or imes. C Rear ofozr4nas 98 in (4S 7 c;n) rrrirnum clearance per 7VFPA4e.�tirg, labelkrg, and IlSting{unie5s state orl4Car codes dictate otherwise. D Windows. and openings NO operably windows, doors, or openings in the w! are WNW ithin 5 1.52 to) from the generator. wf ( any point of Exrsung wall one -hour fire rated walls allow closer placement of the generator set, Conrum before Installation. F Remavable fence Removable fence panels for servicing cannot be placed Less dap g fr (0,91 m) In front of the generator. G Overhead clearance 5ft{1.52 tn) Min imrsn dl_--tanoe from at y sfruohwre, overhang, orProle o[ions from the 1va11. DO NOT ins underwooden decks o�struotum unless this distance is maintained. Installation Guldelin" For60 Hz Air -Cooled Generators 1' vvllwreltcr anclasuro Would nac Me 811y ignition risk to nearby combustibles or structures, wlfli or without rare service personnel response. vviruui y 'Ms °: Ma 7 ta'�J 83: sae PVure 3 ,. SOUMWeStReseerch insatute maw."g Based on this testing and the requirements o� �i NFPA 37, Sec4.1A, the guidelines for installation of the generators listed abovearechanged to 16 in (457 mm)j firo,•n the back side of 'the generator to a stationary wall or building A. For adequate: maintenance and airflow clearance, the area above the generator should be at least 5 ;L (1.62 m) with a minimum of 3 ft (0.91 m) at the front and ends of the enclosure. This includes frees, shrubs, and bushes, parameter not In compliance with these clearance parameeers could obstruct air flow. In addition exhaust fumes from the generator could inhiblt plan,t within the o e l f 'T " `- , and the lnstal:ation drawing caner s manual for detalls. Automatic star- up. i]isconnect utility Power and render unit inoperable before working on unit. Fallure to do so will result in death or serious In)ury. Asphyxiation. Running engines produce carbon monoxide, a colorless, odorless, aieulltnaioivoddwiresuliede,rsdtr irrj�ry (000'iO3) NOTE: If the generator Is not set to OFF -it can Munk and start as soon lathe battery cables are connected. It the Utility power supply is not turned off, sparking can occur at the battery posts and cause an explosion. Site Selection and Preparation Site Preparation Locate the mounting area as close as pD531ble t, the transfer switch and Mel supply. Leave adequate room arourid the area fbr service access (check local code), and place high enougf to keep rising water from reaching the generator. ° Moose an open space that will provide adequate and unobstructed alr7ovc, Place the unit so air vents won't become clogged with leaves, grass, Snow, or debris. Verify that exhaust fumes will not enter any building through eaves, windows, ventilation fans, or other air intakes (see �ve ° Select the type of base, such as --but not limited o compacted soil, gravel, or concrete, as desired or as required by local laws or codes. Vedry your focal requirements before selecting. 041terial Sufficient for Level Installation ° Prepare a rectangular area approximately S In (127 mm) deep (A) and approximately 6 in (152 mm) longer and wider (8) than the footprint of the generator verify that the surface where the generator MR be mounted Is compacted, leveled, and will not erode over time. A concrete pad can be Poured if desired or required. Mrls_-� C=��E1/��— •-• ----+rrr 4 �L✓ Figure 2•3. Compacted'sworGraveiPad dtiOTS,' If a concrete pad is required, follow all applicable federal, state, or local codes. .vaauSu,u', wu,uennes r•orW Hz Air -Cooled Generators 9s