Loading...
HomeMy WebLinkAboutENGINEERINGSCANNED BY tLuCie CoIinty TURQUOISE Engineering, LLC Structural Engineering, Design & Testing, CA #28948, NOA #18-0222.01 901 Forest Hill Blvd., W Palm Beach, FL 33405 / Ph (561) 804-9908 / Fax (561) 804-9907 / e-mail: turginc@aol.com August 31, 2018 TO: St Lucie County / Building Department REF.: Inspection of Roof Framing and Deck Repair for Chimney Removal ADDRESS: MITCHELL Residence / 6901 Salerno Rd., Ft Pierce, FL 34951 CONTRACTOR: Code Red Roofers RECEIVED PERMIT #: 1805-0324Tr, SEP B 5 2C18 ° S7. Lucie county, Permitting Dear Sir; i The portion of the chimney existing over the roof deck of the subject residence is cut and removed. The purpose of this inspection was to determine the level of code conformance for re -framing and isheathing of that area based on requirements of Wood Construction; 2017 Florida Building Code, Existing. The following finding and observations are made: 1) The existing metal chimney shaft (flue) is removed. 2) The new and existing headers are adequately secured to existing roof trusses. 3) The truss top chords are;properly secured to new load -bearing ledger. 4) New 19/32" CDX plywood sheathing is provided with 2x4 nailer's and fastened to new framing using 8d ring-shanked nails spaced at 4" o.c. 5) The roof edge is provided with drip -edge metal, and primed to receive roof underlayment, 6) The roof deck is dried -in fusing direct -deck applied Tarco PS200 self -adhered underlayment and properly roll -pressed. 7) The roof is ready to be covered using Extreme 5V-Crimp metal roof panels. 8) The homeowner is made sure to accept the responsibility of blocking the fireplace and chimney from inside the living room. Therefore, this letter is to certify that roof re -framing and plywood sheathing of the removed chimney area are completed conforming to requirements of 2017 Florida Building Code for Risk Category II in Exposure D area. If you have any questions regarding this or any other matter, please do not hesitate call. Respectfully, Riza Ny A Consultin l qn'�' '03ZIt E. 38521 ST. LUCIE COUNTY BUILDING DIVISION REV, I IEW ED FOR CO P E REVIEWED BY i DATE PLANS AND PER IT MUST BE KEPT ON�JOB OR NO INSPECTION WILL BE MADE Qtt0.t18808��®B AQq p No.38521 STATE OF w• o � a*0 8 'S/O 0 8 L 0%�a@®