HomeMy WebLinkAboutBUILDING PLANJ. PAUL MAHFOOD RESIDENCE ST. LUCIE COUNTY, FL PROPOSED RESIDENCE: CUSTOM HOME 7832 SADDLEBROOK DR. PORT ST LUCIE, FL 34986 SABAL CREEK - PHASE I - LOT 9 BUILDING DEPARTMENT PRODUCT APPROVAL SUBMITTAL DATA p._ PRODUCT BUILDING DESIGN PRODUCT DESIGN NANUFACTURER MODEL PRODUCT GLASS ATTACHMENT METHOD PRESSURES (PSF) PRESSURES (PSF) NUMBER APPROVAL NO. DESCRIPTION TYPE, SIZE, SPACING & EMBEDMENT WINDOWS SEE 185 SH FL# We X i-Ya' MIN. EMBED. TAPCONS ELEVATIONS +/-55.0 MI IMPACT 17499.1 AT 2"/16" O.C. SEE FL# Y+" X 1-Y4" MIN. EMBED. TAPCONS MULLIONS ELEVATIONS +/-54.0 MI GM 18532 N/A 15353.9 (4 PER CLIP) SEE +/-55.0 185 PM FL# -X6" X 1-Y4" MIN. EMBED. TAPCON AT FIXED GLASS ELEVATIONS MI IMPACT 15349.5 3"/12°' O.C. SEE FL# Y4" X 1-Y4" MIN. EMBED. TAPCONS SWING DOORS ELEVATIONS +/-67.0 THERMA-TRU SMOOTH STAR N/A 20468.4 AT 6"/14.5°' O.C. SEg FL# Y4" X 1-Y4" MIN. EMBED. TAPCONS SWING TYPE DOORS ELEVATIONS + 50.0 /- THERMA-TRU SMOOTH STAR IMPACT 20468.10 AT 3"/14.5°' O.C. SEE FL# X" X 1-Y4" MIN. EMBED. TAPCONS FRENCH DOORS ELEVATIONS +/-50.0 THERMA-TRU SMOOTH STAR IMPACT 20468.11 AT 3"/14.5" O.C. SEE +36.0 DAB 824/811 NOA# N/A We"X 1-%" MIN. EMBED. LAG SCREWS GARAGE DOORS 16' ELEVATIONS -44.0 17-1018.12 AT 12' O.C. see +50.0 824/811 NOA# N/A We" X 1-%" MIN. EMBED. LAG SCREWS GARAGE DOORS 8' ELEVATIONS -60.0 DAB 17-1018.13 AT 12" O.C. GALENA FL# ROOFING MATERIAL -83.7 -185 ENTEGRA SPANISH N/A PER ROOF ASSEMBLY ON PLAN S" 7804.2 1. ALL GLAZED EXTERIOR OPENINGS SHALL BE IMPACT OR PROVIDED WITH SHUTTERS. W 2. MAIN EGRESS DOOR MUST BE IMPACT RESISTANT. h 3. ALL GLASS SHALL HAVE A U-FACTOR LESS THAN OR EQUAL TO 0.40 ABD SHGC LESS OR EQUAL TO 0.25. 0 4. WINDOW AND DOOR FENESTRATION SHALL BE IN ACCORDANCE WITH FEMMA/AMA 200-9. CONTRACTOR SHALL SUBMIT z FMMA/AMA 200-9 STANDARDS WITH PERMIT SUBMITTAL. I HAVE REVIEWED THE ABOVE PRODUCT APPROVAL INFORMATION AND APPROVE IT. NAME: PAUL WELCH P.E. CERTIFICATE NUMBER: 29945 STRUCTURAL NOTES 1. DESIGN LOADS IN ACCORDANCE WITH ASCE7-10. 2. SOIL BEARING CAPACITY: 2500 PSF (MIN.). 3. ALL STRUCTURAL CONCRETE IN BEAMS, LINTELS, VERTICAL CELLS, AND COLUMNS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. 4. SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS. 5. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3" BEAMS: 1 %" SUSPENDED SLABS: 1 Y2" 6. LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS EXCEPT AS NOTED GRADE 60 STEEL MINIMUM IN BEAMS AND COLUMNS. 7. ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. B. SPLITTING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALLATION OF HARDWARE IS NOT PERMITTED. 9. UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICES. 10. LINTELS SHALL HAVE A MINIMUM 4" BEARING, 11. PROVIDE # 5 CORNER BARS W/ 30" MIN. LAP SPLICE FOR BOND BEAM. 12. STUCCO CEILINGS AND SOFFIT NOTE: EXTERIOR CEILING AND SOFFIT TO BE STUCCO OVER WIRELATH W/ 11GA. 2" NAILS W/ 3/8" 0 HEAD 0 6" O.C. OVER 3/8" METAL RIB LATH 0 6" O.C. W/ (2 LAYERSOF 15# FELT OVER EACH FRAMING MEMBER). 13. EXTERIOR FRAME WALLS TO BE STUCCO OVER WIRELATH WITH 11 GA. 2" LONG NAILS WITH 3/8" 0 HEAD 0 6" O.C. OVER (2) LAYERS OF (15# FELT OR TYVAK BUILDING WRAP) OVER 19/32" CDX PLYWOOD WITH 10D NAILS TO STUDS 0 6" O.C. PERIMETER AND FIELD. 14. BEARING POINTS OF TRUSSES SHALL HAVE VERTICAL STUDS IN A NUMBER EQUAL TO THE NUMBER OF PLIES OF THE BEARING MEMBER WHEN THE BEARING MEMBER IS (2) OR MORE PLIES UNLESS NOTED. WALL FINISH/INSULLATION NOTES 1. INTERIOR TO BE t/i" DRYWALL FINISH. 2. ALL INTERIOR GYPSUM BOARD TO BE MIN. X" THICK WITH (13 GAGE, 1 3/8" LONG, 19/64" HEAD; 0,098" DIAMETER, 1 9" LONG, ANNULAR -RINGED; 50 COOLER NAIL, 0.086" DIAMETER, 1 5/8" LONG, 15/64" HEAD; OR GYPSUM BOARD NAIL, 0.086" DIAMETER, 1 5/8" LONG, 9/32" HEAD) SPACED AT 7" O.C. FOR NAILS AND 12" O.C. FOR SCREWS. 3. WALLS AT SHOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR C 1278 AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN SHOWER AREAS. (PER FRC 702.4.1 & FRC 702.4.2). 4. WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450. 5. WALL AND CEILING FINISHES SHALL HAVE A FLAME -SPREAD CLASSIFICATION OF NOT GREATER THAN 200. 6. ALL EXPOSED INSULATION MATERIALS INSTALLED ON ATTIC FLOORS SHALL HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.12 WATT PER SQUARE CENTIMETER. EXPOSED FOAM PLASTIC INSULATION MATERIALS EXPOSED TO THE UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL COMPLY WITH SECTION FRC316. 7. PER FRC 702.2.1 ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL CONFORM TO ASTM C 36, C 79, C 475, C 514. C 630, C 931, C 960, C 1002, C 1047, C 1177, C 1178, C 1278, C 1395, C 1396 OR C 1658 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF FRC, AND ADHESIVES FOR THE INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557. 8. INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR ILL 723. Planning & Development Services Department Building & Code Regulations Division WNW 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 1 Certification for Delal&n Load Compliance Project Name: MAHFOOD RESIDENCE Project Address: 7832SADDLEBROOK DR. Permit lh Occupancy Type: R Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications Involving the following: o New Residences (single or multifamily) a Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for Interior renovations provided that no exterior structural elamems are affected and certain minor building Permits at the discretion of the local building official. Contact the# above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that aoolvl 1. DESIGN CODE: Florida euiltline Code 2017 Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as lcheck one): %Enclosed _Partially Enclosed _Open 3. Risk Category: _I X It III_ V Exposure Category: _ B X C D 4. Design Wind Velocity 160 mph 124 ASD N/ALRFD Eml Zone Width: S it S. Mean Roof Height: 20 It Roof Pitch: s 12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 30sgft @ 15'MRH, clearly label on all plan openings): Y0.5 20.5 20.5 35.5 35.5 33.7 Zone 1: Zone 2: Zone 3: Zone 4: Zone S: Garage: -32_5 -56.6 -83.7 -38.5 -07.6 -43.9 7. Design Loads: Floor: 40 PSF Roof/Dead: 10 PSF Roof/Live: ZO Balcony:, N/A PSF Dock: N/A PSF Deck: N/A PSF Stain: N/A PSF Fence: N/A PSF Railings: N/A PLF/CONCENTRATED B. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing prMsure; ZS00 PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currelniy, adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Paul Welch P.E. 29945 / 5115 Print Name Cert # & Co. Cart Auth. Paul Welch Inc. 1984 S.W. Biitmore St. Suite #114 Port St. Lucie, FL ON PLAN 1/17/2018 Signature, Date, and Seal' SLCCDV Form If 020.12 Rev1s@0 3115/12 (IS) Company Name & Address GENERAL NOTES 1. THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. 2. STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. 3. ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4. ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE (FBC) 2017, FBC 2017 RESIDENTIAL, FBC 2017 PLUMBING CODE, FBC 2017 MECHANICAL CODE, FBC 2017 ENERGY CONSERVATION, AND THE NEC (NFPA 70) 2014 EDITION. 5. RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY HEAVY TERMITE INFESTATION AREA PER FRC 301. 6. ALL ADDITIONS, REPAIRS, AND ALTERATIONS MUST COMPLY WITH THE F.B.0 2017 FOR EXISTING BUILDINGS. PLUMBING NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE FBC 2017-PLUMBING 2. DWV PIPING SHALL BE SCHEDULE 40 PVC. 3. WATER PIPING IN BUILDING SHALL BE ONE OF THE FOLLOWING: TYPE L COPPER, CPVC, OR PEX. 4. SLEEVE ALL PIPING IN CONTACT WITH CONCRETE OR UNDERGROUND WITHIN BLDG. 5. HOT WATER PIPING WITH A MINIMUM THERMAL RESISTANCE OF R-3 SHALL BE APPLIED TO PIPING LARGER THAN 'W' NOMINAL DIAMETER, PIPING FROM WATER HEATER TO KITCHEN OUTLETS, PIPING LOCATED OUTSIDE THE CONDITIONED SPACE, PIPING FROM THE WATER HEATER TO THE DISTRIBUTION MANIFOLD, PIPING LOCATED UNDER THE FLOOR SLAB, BURRIED PIPING, SUPPLY AND RETUN PIPING IN RECIRCULATION SYSTEMS, PIPING WITH RUN LENGTHS GREATER THAN 20 FEET. 6. WATER HEATERS INSTALLED SHALL BE IN ACCORDANCE WITH FBC 2017 ENERGY CONSERVATION. ELECTRICAL NOTES 1. ALL ELECTRICAL WORK SHAL BE IN ACCORDANCE WITH THE NEC (NFPA 70) 2014 EDITION. 2. A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFACY LAMPS OR A MINIMUM OF 75% OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH-EFFACY LAMPS. (LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED TO BE HIGH-EFFACY LAMPS). 3. RECESSED LIGHTING SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONED AND UNCONDITIONED SPACES. 4. SMOKE DETECTORS TO BE 110V W/ BATTERY BACK UP - ARC FAULT CIRCUIT. 5. SMOKE DETECTORS TO BE LOCATED AS SHOWN, AND INSIDE AND OUTSIDE OF ALL EXISTING BEDROOM INTERIOR DOORS (NOT SHOWN) IF NOT EXISTING VERIFY. 6. SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE. 7. PROVIDE BRANCH CIRCUIT ARC -FAULT PROTECTION FOR ALL CIRCUITS SERVING: FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS PER FBC AND NEC REQUIREMENTS. 8, PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 125-VOLT, SINGLE-PHASE 15 AND 20 AMP CIRCUITS SREVING: BATHROOMS, GARAGES, KITCHENS, ACCESORY BUILDINGS, OUTDOORS, OR WITHIN 72" OF EDGE OF ANY SINK. 9. CARBON MENOXIDE DETECTORS TO BE INSTALLED WITHIN 10' OF ALL BEDROOMS. 10. EXHAUST FANS TO BE VENTED THRU ROOF OR SOFFIT. 11. PROVIDE TAMPER RESISTANT RECPTICLES PER NEC (REQUIREMENTS. 12. TIE ELECTRICAL INTO EXIS11NO ELECTRICAL SERVICE. ENERGY CONSERVATION NOTES 1. RESIDENCE SHALL BE IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017 ENERGY CONSERVATION RESIDENTIAL. 2. ATTIC ACCESS DOORS OR HATCHES FROM CONDITIOND SPACES TO UNCONDITIONED SPACES SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES, A WOOD FRAMED OR EQUIVALENT BAFFLE OR RETAINER IS REQUIRED TO BE PROVIDED WHEN LOOSE FILL IS INSTALLED, TO PREVENT LOOSE FILL FROM SPILLING INTO THE LIVING SPACE. 3. THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR LEAKAGE IN ACCORDANCE WITH THE REQUIREMENTS R402.4.1 THROUGH R402.4.4. 4. THE BUILDING SHALL BE TESTED FOR AIR LEAKAGE IN ACCORDANCE WITH R402.4.1.2 5. WINDOWS, SKYLIGHTS, AND SLIDING GLASS DOORS SHALL HAVE AN AIR INFILTRATION RATE OF NO MORE THAN 0.3 CFM PER SQUARE FT, AND SWINGING DOORS NO MORE THAN 0,5 CFM PER SQUARE FT AND MUST BE TESTED LISTED AND LABELED IN ACCORDANCE WITH R402.4.3. 6. CONTRACTOR SHALL PROVIDE ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD IN ACCORDANCE WITH FBC 2014 ENERGY CONSERVATION R401.3. GARAGES FLOOR SURFACE 1. GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL. 2. THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY. 1101101 DOWEL ROD REPAIR NOTES IN THE EVENT STEEL HAS BEEN INADVERTENTLY OMITTED FROM DOWN POUR LOCATIONS, DRILL 6" INTO CONCRETE (NO CLOSER THAN 3V' FROM EDGES AND 5" FROM ENDS OF CAP WALLS). REMOVE DUST PER MFG'S INSTRUCTIONS AND USE TWO PART EPDXY TO ANCHOR #5 REBAR IN PLACE, USE EITHER HILTI C-100 OR SIMPSON EPDXY -TIE. StLuciecou* FILE COPY ST. LUCIE COUNTY BUILn DIVISION REVIEWED FOR COMPLIANCE o PLANS AND F1ERMi'f MUST BE KEPT ON JOB I SITE OR NO INSPECTION(S) WILL BE MADE ij� - DRAFITNG SERVICES JOAN JAPPE. LLC wwPHONE:(7772) 237-794.co,n W a � � m o r "n d A "U 0� U z a 0 0 z� 0 A E 4 A 6 z W UU H F"I H 00 Q H ^ w W A�W 0 0 GNU 000a � U 5� F--1 s PAUL WELCH INC. MECH-ELEC-CIVIL ENG 1984 SW ETI.TMORE ST. # (14 PORT ST EOCM, F 34984 PAUL. WELCH, P.F. FLA REG. No. 2954 I FEB 1 5 2018 Date: SCALE: N.T.S. JOB No: 517-0639 C CONCRETE 2' SLAB EDGE (VERIFY SIZE w/HOMEOWNER) F p TY x c �p w a M ==B x 90 MEDIA ROOM ■ ■ INVERTED VAULTED/TILE -" R )ZWa I n 00 v m i� ■ lul 0 • 0a IX (I = GO 00CID IJj O M Uo o m 7'-6" r==ri , 4'-8" L-11 GRANT E SILL 25SH EGRESS 23SH TEMP. ■ I o I I I 2,- a o DO ow2 I� BATH 3 m Owl o c0 x 9'-1" CLG/TILE 81 0 IN eel (o I � I ip LINEN co----� a GYM T-1" CLG/CARPET 8' -1" 35SH EGRESS W/ RCH L-17 15'-2" MEDIA ROOM/ BEDROOM #3 VAULTED/TILE 868 TYPIC L INTERIOR (NON -BEARING) oQ PARTITION WALLS OF METAL STUDS @24" O.C. ON 2" P.T. SOLE PLATE W/1/ " GYPSUM BOARD DRYWALL (U LESS OTHERWISE NOTED) STEAL BEARING POST FAMILY 11'-1" CLG/TILE 4'- 3 11 -1 1 (n V V 37'-2„ GRANT SILL L-10 A/C L-9PUMP IRRIGATION ■ 23SH TEMP. 35SH EGRESS UNI ro N IN L-11 o AQUASALOCATION A HO SE FILTER ugRY 8'-6" 4'-6 - 45'-8" m> ® oo LO 0 m 00 BEDROOM #2 L�o „ IT'd ATH #2 `0 x o VAULTED/TILE oIN9' tAH ao 1„CLG/TILE r OMETAL. /O� DNEN I o r-1 3 CAR GARAGE S ELVES �1668BCO I I 9'-4" CLG/CONCRETE �° h� ITO roo Io M ? � 1al 1 t 42" HIGH BAR \ TOP COUNTER o LL ..LOLL L- 6 LLLLLLLLL LLLLLLLLLLL L-15 5080FR DOUBLE DOOR '• ■ ■ i ■■ ■ ■ ■ ■ ■ , a -14 26 s ■ o NOOK � Epoo 0 o M 11'-1" CLG/TILE HUTDOOOWERR x 10'-7" 14'-3" L-18 I N �IV zl H36 SH 0,2'-0" ' 2'-6" 32 40'x41' CONCRETE SLAB c.l a 1 � ■ NOTES: I o 40'x41' CONCRETE SLAB (1Y2"Wx3Ya'H DECKO I o uj DRAIN) (VERIFY SIZE AND LOCATION WITH I m HOMEOWNER) PROVIDE FOOTINGS PER SCREEN o I ENCLOSURE ENGINEER. I o SCREEN ENCLOSURE BY OTHERS IN PORCH o (SEPARATE PERMIT) 0) 9'4"/CONC. 00 (VERIFY SIZE AND LOCATION WITH HOMEOWNER) alo ■ m I 28 8 Z L a 8" WALL 3" VTR — —� r---Ir ------ o---- N ugRv DR W gONNLOCAY ON LI L AV K N UJa O OO w/VENTTHRU ROOF MICROWAVE I �3 9'-1" 4G/TILE 8'-8 20 N. FI E '-0" O o ®z DRYER c oslNc 2868 VENT 2868 SC xm OfZ tO LLJ � N ISLAND 10\ --------- ■ ■ r N I \F — — — — — — — — — (I HB 11 8'-0' KITCHEN r �-r' CLG/TILE �PAiE 0 I I I DINING ROOM I I 1 TRAY CLG./TILE t I 3 0 I I I RAISED FLOOR 4" 1co I I N 1 T&G PLYWOOD I N J O) J X4 SHEATHING OVER 2P.T. I I SLEEPERS 016" O.C.) I I I ^ s `H N // \z------ �Q� H1 11'-1" CEILING �� — W(4g IRSE) 8"0x10'H CUT TO FIT ENDURA-STONE COLUMN ()NP.) O 2 —1 D u (LOCATE BY HOMEOWNER) UO TOP -6 O� III ill Lip 60 0 I� �Z N rr 3'-11" 4'-8" 3'-0" FOYER 1 COO I � L7 III 14'-1" CLG/TILE 1 Z 'w II N 0 oLL w Ln III I 00 LIVING 11'-1" CLG/TILE µ V ro 5'-2" 7'-1" 5'-0° ILI 14'-4" I 12" SQ. MASONRY PASS-THRU COUNTER 0I LEGEND COLUMN BLOCK w/ (4) #5 (MIN.) 266 SC ■ 36" AFF STUDY ° ih 16"H x 8" CMU MASONRY WALL in VERT. BARS GROUTED J GRANITE TOP 11'-1" CLG/TILE -7 '-0 k SOLID (4 TYPICAL) RAISED FLOOR 4" zI HALF BATH o (�: T&G PLYWOOD 2021'-4"H x 8" CMU MASONRY" WALL a SHEATHING OVER 2P.T. SLEEPERS O18" O.C.) 3'-2' 2'-2" 5 -o" 3 WET BAR O a R-13 INSULATION ° I INTERIOR 2x4 STUD NON -BEARING • PARTITION WALL i �' P CUSTOM BUILT-IN BOOKCASE (PER HOM WN€R) PRE -CAST CONCRETE LINTEL It L-1 DESIGNATION (SEE SHEET-A6) ■ �F�� 12066 I F22"x36•� I VTR SOIL PIPE VENT THROUGH ROOF I ♦ P / / IATnC ACCESSI I L___J 25 SH WINDOW MARK (ALL IMPACT) I N 5� �w , / / / / I SH & RD W.I.C. I (SEE MANUFACTURER'S SPECS �I I �� / / I I N 40686E 2868BF Io FOR DETAILS) zi t4 .. / / I N 6080 FR DOOR MARK (ALL IMPACT) a N ■ TRAY CLG/TILE MASTER BDRM. I 5'-1" 6'-9' (6'-C"W x 8'-O"H j � o MASTER BATH. i i OPENING) NOMINAL 7 i CD CD T-1" CLG/TILE 5068SLD N Z 22'-6" I I 1 9'-0" 14'-13/" I W.LC. I I ti�--------------- 40'x41' CONCRETE SLAB EDGE ■ — — �` ■ ■ ■ ■ ■ ■ ■ ■ ■ ILL H36 SH H361SH_ -1 ] L-133I1 5'-11" 12'-0" 25'-9" 3'-2 43'-8" 3'-6' 52'-0„ 86'-2" Z� d . _ /w l\ _ m 12 DIA. COLUMN BLOCK OVER 20" SQ III MASONRY BLOCK BASE REINFORCED N a III W/(2) #5 VERTICAL BARS GROUTED II1N 01 1 SOLID (2 PLACES TYPICAL) x IIIN o N M III ■■■ ■•• 16070 OHG 8070 OHGD [[.--T 16'-0" 2'-0" 1, 8'-0" 3'- 1 38'-4" -6" 3'-6" 0 I = 12" DIA. COLUMN BLOCK OVER - 20" SQ. MASONRY BLOCK BASE 3 o REINFORCED w/ (2)#5 VERTICAL BARS N GROUTED SOLID (8 PLACES TYPICAL) N 0- o ao SPORTS SHOWER IN Q J IIIN N III i BUILDER'S NOTES 1. GRANITE COUNTERTOPS FOR ALL BATHROOMS, KITCHEN, & WET BAR 2. GRANITE SILL ® ALL WINDOW SILLS 3. BUILT-IN UNITS SIZE AND LOCATIONS PER HOMEOWNER BUILDER 4. WELL CONNECTION 5. SEPTIC CONNECTION 6. WHOLE HOUSE AQUASANA WATER FILTRATION SYSTEM TO BE INSTALLED 7. 8"0 X 1O'H (CUT TO FIT) ENDURA-STONE COLUMN IN FOYER (BUILDER LOCATE) 8. CONTRACTOR SHALL PROVIDE LIGHT POLE PER OWNER'S SPECIFICATIONS �t MIRROR o a� 0 o i cV II II 0 0 MASTER BATH VANITY DETAIL (VERIFY DESIGN w/HOMEOWNER) AREA TABULATION LIVING: 4,218 SQ. FT. GARAGE: 1,073 SQ. FT. ENTRY PORCH: 150 SQ. FT. COV. PATIO: 418 SQ. FT. T TAL: 5,859 SQ. FT. UNIT 1 — A/C VOLUME: 27,832 CU. FT. UNIT 2 — A/C VOLUME: 18,221 CU. FT. NOTE: PROVIDE SPRAY FOAM INSULATION AT ROOF DECK ALL AREAS ABOVE LIVING SPACE 5 BEAM HANGER MARK TYPE "SIMPSON" HUC410 WITH H1 (18)-1/4" X 2 3/4" TITEN TO WALL AND (10)-10d NAILS TO BEAM ij� - DRAFTING SERVICES SOAN IAEHE. LLC PHONE: (772) 237-7942 NNW.1n61sUaecwsry � a � w .-; rn m o r a �u a z O A W W W A m 00 00 m co co 0 11 00 00 O z444 W U W 0 vl AFO w 0 A wua ® q�w E+ w 0 Naa GO 0 PAUL WELCH INC. MECH-P.LEC-CIVII., ENO 1984 SW BILTMORE ST. #114 PORT ST LUCIE, FL 34984 PAUL WELCH, P.E. FLA REG. No. 29945 Da,dUN 1 1 2018 SCALE: 1/4" = P-O" JOB No: 517-0639 Al 7'-9" T.O.W. 0'-0" F.F.E. L- d" RAISED STUCCO TRIM (TYPICAL WHERE INDICATED) 16" STUCCO FINISH MASONRY COLUMNS w/DECORATIVE PRE -CAST BASE & CAPITAL TRIM (TYP. FRONT COLUMNS) CALCULATE ATTICy,-_NTILATION COVERED PORCH CEILING = 418 SQ. FT. 418 /150 = 2.79 REQUIRED VENTILATION 47 L.F. OF 4 " CONT. VENTING = 15.7 SF / 2 7.8 SF AVAILABLE FOR CROSS VENTILATION 7.8 SQ. FT. > 2.79 SQ. FT. : VENTILATION O.K. GARAGE CEILING = 1073 SQ, FT. 1073 /150 = 7.15 REQUIRED VENTILATION 100 L.F. OF 4 " CONT. VENTING = 33.3 SF / 2 = 16.7 SF AVAILABLE FOR CROSS VENTILATION 16.7 SQ. FT. > 7.15 SO. FT. : VENTILATION O.K. ENTRY CEILING = 150 SQ. FT. 150 /150 = 1 REQUIRED VENTILATION 25 L.F. OF 4 CONT. VENTING = 8.33 SF / 2 = 4.2 SF AVAILABLE FOR CROSS VENTILATION 4.2 SQ. FT. > SQ, FT. : VENTILATION O.K. , 12 61 A REMOVED RIDGE VENTS FRONT ELEVATION SCALE: 1/4" = 1'-0" c� W_ 31 00 W 11 11 3E io w x .a REAR ELEVATON SCALE: 1/4" = V-0" TILE ROOF 20" SQ. MASONRY COLUMN BASE APPLIED DESIGN PRESSURES (PSF) MARK AREA I E ZONE 4 ZONE 5 POSITIVE (PSF) NEGATIVE (PSF) POSITIVE (PSF) NEGATIVE (PSF) 1 10 35.5 -38.5 35.5 -47.6 2 15 35.4 -38.5 35.4 -47.4 3 20 35.3 -38.4 35.3 -47.2 4 25 35.3 -38.3 35.3 -47.0 5 30 35.2 -38.2 35.2 -46,8 6 35 35.1 -38.1 35.1 -46.7 7 50 34,8 -37.8 34.8 -46.1 8 110 33.7 -36.7 33.7 -43.9 DECORATIVE PRECAST OR STUCCO COLUMN CAPITALS ON 12"0 STUCCO FINISHED MASONRY COLUMNS 12 6 x uW 1 0 Lu E 2E E W x a: 1 ^ 2 a O.H." (TYP.) DRAFTING SERVICES LOAN IAFPE. I C PHONE: (772) 237-7942 www.ixe..s�xemneava.wru�o.coa m a C m o t V1 rA W A A U u 0 z ° oAu H a � A 00 R zd OU �z 'p^ v! ADO P"1 � H 0 0 � 0 w�a O NI~V Ix a� rl PAUL WELCH INC. MECH-ELEC-CIVIL ENG 1984 SW BE.TNIORE ST. k114 PORT ST LUCIE. PL 34984 PAUL WELCH, P.E. PLA PEG. No. 29945 JUN 1 1 2018 Date: SCALE: 1/4" = 1'-0" JOB No: 517-0639 A2 lue TEXTURED CEMENT STUCCO COATING OVER 8' CMU BLOCK WALL (TYPICAL) 21 3i --------------------- A REMOVED RIDGE VENTS ,. ~ J ^ t, w = 11 0� Ip 31 ip w --------------------- RIGHT ELEVATION SCALE: 1/4" = 1'-0" �Tf I All I All I IF I TEXTURED CEMENT STUCCO COATING OVER TF 1E 8" CMU BLOCK WALL (TYPICAL) LEFT ELEVATION SCALE: 1/4" = 1'-O" APPLIED DESIGN PRESSURES (PSF) MARK AREA I E ZONE 4 ZONE 5 POSITIVE (PSF) NEGATIVE (PSF) POSITIVE (PSF) NEGATIVE (PSF) 1 10 35.5 -38.5 35.5 -47.6 2 15 35.4 -38.5 35.4 -47.4 3 20 35.3 -38.4 35.3 -47.2 4 25 35.3 -38.3 35.3 -47.0 5 30 1 35.2 -38.2 35.2 -46.8 6 35 35.1 -38.1 35.1 -46.7 7 50 34.8 -37.8 34.8 -46.1 8 110 33.7 -36.7 33.7 -43.9 O.H. (TYP.) 11 Ally _ S��I�i��iNi���������i�iA���i��A� I I DRAFPINO SERVI( JOAN 1A .LLC PHONE: (72) 237-77 m C C a � W A U PAUL WELCH IN, MECH-ELEC-CIVIL 1984 SW EILTMORE SI PORT ST LUCIE, FL 3 PAUL WELCH, P.E. I R . No. 29945 JUN 1 12011 Date: SCALE: JOB No: 517-063 A3 OPEN CELL SPRAY POLYURETHANE FOAM APENDIX X Y2 THICK CEILING RATED GYPSUM — WALLBOARD SHEATHING (OTHERWISE NON —RATED W THICK GYPSUM WALL BOARD IS REQUIRED) Y2" GYPSUM WALLBOARD SHEATHING OVER Vx2" (NOMINAL) P.T. FURRING STRIPS 0 24" O.C. (MAX.) AND R4.1 FI—FOIL INSULATION WITH REFLECTIVE VAPOR BARRIER WOOD BASE BOARD 3—Y2" THICK (MIN.) POURED CONC. (2500 PSI MIN.) FLOOR SLAB WITH 6x6—W1.4xW1.4 (MIN.) W.W.M. (OR FIBER MESH) OVER 6 MIL POLYTHENE VAPOR BARRIER & COMPACTED TERMITE TREATED CLEAN SOIL FILL (SEE SHEET—P1 FOR FOUNDATION NOTES) 5 S1 1 TILE ROOFING OVER UNDERLATMENT f(ASTM 7158H, OR CODE APPROVED EQ.) 19/32" C—D STRUCTURAL I PLYWOOD SHEATHING OVER PRE—ENGINEERED WOOD TRUSSES 0 24" O.C. (SEE ROOF FRAMING PLAN SHEET—R2 FOR ROOF SHEATHING NAILING SCHEDULE) 12 GALV. METAL TRUSS ANCHOR STRAP �6 (TYP) (SEE SHEET—R2 FOR TRUSS CONNECTOR SCHEDULE) 24" TYP. TRUSS TAIL 2Y2" ALUMINUM DRIP EDGE OVER 1x3 P.T. NAILER O.H. z 0 > w J w Ln w 3" MIN. AR CO (TYP.). SHOP DRAWINGS APPROVED PRE —FABRICATED WOOD TRUSSES 024" O.C. Y8" GAP (U.O.N SIMPSON STRONG —TIE ROOF TRUSS CLIP ,TYPE STC (1 CLIP 0 2x4S, 2 CLIPS 0 2x6S, 3 CLIPS 0 2X8S) (NOTE: EQUAL ANCHORS MAY BE SUBSTITUTED) FIRE BLOCKING (SEE NOTE #1) USE .145" DIA P.A.F. 016" O.C. TO CONCRETE w/ TAPCONS OR CUTNAILS 24" O.C. WOOD BASE BOARD MOLDII\ �'�1x2 P.T. DRIP EDGE 2x6 CONT. SUB FASCIA BOARD NAILED TO EACH TRUSS TAIL W/ (2) 16d CoM. NAILS (OR BETTER) '5\ **STUCCO FINISHED SOFFIT OVER HIGH RIBBED SEL J FIRRING METAL LATH 4" CONTINUOUS SOFFIT VENT CONT. x4 T. LEDGER 80ARD w Ya x3" TAPCONS 024" O.C. (OR BETTER) DOUBLE COURSE 8" CMU KNOCKOUT/BOND BEAM BLOCK GROUTED SOLID TYPICAL FOR PERIMETER WITH (1) # 5 REBAR CONTINUOUS NEW 8" CMU WALL CONSTRUCTION WITH TYPE "M" MORTAR Y2" MIN. CEMENT STUCCO COATING #5 VERT. REBAR AND #5 DOWEL BARS WITH STD. 10" LONG HOOK (MIN.) GROUTED SOLID. SET DOWELS AS INDICATED ON PLAN 30" MIN. LAP SPLICE (TYPICAL) (� 3/a'x 8" WIDE BLOCK RECESS FINISHED FLOOR SLAB,-L ,,,,,,, .,.FINAL GRADE 18" WALL and STC CUP RAT RUN 1x4 (MIN.) LAID FLAT 08'-0" O.C. �12" MIN. EMBEDMENT BELOW EXISTING GRADE (2) #5 CONTINUOUS REBAR **SOFFIT VENT SHALL BE AT: COVERED PORCH, ENTRY AND GARAGE ONLY. SOFFITS ONLY. SCALE: 1/2" = 1'-O" " GYPSUM WALLBOARD SHEATING — 2x4 CONT. TOP PLATE OR LIGHT GAUGE METAL T—TRACK WOOD STUDS LIGHT GAUGE METAL C—STUD 2x4S 0 16" O.C. FOR H=8' TO 10' 3 1/2" 0 24" O.C. FOR H=8' TO 10' 2x6S 0 24" O.C. FOR H=10' TO, 14' 3 1/2" 0 16" O.C. FOR H=10' TO 14' WOOD STUD TO PLATE 2-16d NAILS 0 2x4S 3-16d NAILS 0 2x6S Yg" GYPSUM WALLBOARD SHEATING PRE —CAST CONC. LINTEL SEE LINTEL SCHEDULE SIZE & REINFORCEMENT CENTERED 16" LONG 2x8 P.T. (SYP) BLOCKING FOR TORSION 4 SPRING (AS REQUIRED) 0o FEW II1 II II II II II > Y2" DIA. WEDGE ANCHOR 3—Y2" EMBEDMENT w/2" 2x6x16'—O" P.T. (SYP) ATTACHED SQUARE WASHER w/ Y4% x 3" TAPCONS 016' O.C. w/ 1" DIA. MIN. WASHERS 2x6 P.T. (SYP) WOOD JAMB FASTENED w/ %%342" (S.S. 304) HILTI KWIK BOLT 3 EXPANSION ANCHOR (OR EQUAL) w/ 2" SQUARE WASHER (SEE BUCK DETAIL) 0 1 � GARAGE FLOOR SLAB-00 = 0 = Li Li Li �� II II II II II � II II II "t I II II IIt I I II II II II II II II I II II u• f IIII• FOOTING PER FOUNDATION PLAN METAL STUD WALL FRAMING NOTES: (2)#5 DOWEL WITH 30" OVERLAP 1. WHEN METAL STUDS ARE SELECTED FOR INTERIOR NON —BEARING PARTIOTION WALL FRAMING SHALL CONSIST OF COLD —FORMED STEEL MATERIALS AS FOLLOWS: A) 3)z" METAL STUD: 3 1/2" (25 GA.) COLD —FORMED STEEL STRUCTURAL C—SECTION PRODUCT DESIGNATION: 350S162-43; 33 KSI, G60 (OR BETTER) B) 3Y2" METAL TRACK: 3 1/2" (25 GA.) COLD —FORMED STEEL STRUCTURAL T—SECTION PRODUCT DESIGNATION 350T137-33; 33 KSI, G60 (OR BETTER) 2. BOTTOM TRACK STUDS SHALL BE FASTENED TO THE CONCRETE FLOOR SLAB WITH POWDER — ACTUATED 0.22 CALIBER (MIN.) SHOT PINS, 1" LONG x 0.300 HEAD DIA. x 0.145 SHANK DIA, WITH 7//6" DIA. STEEL WASHER, PLACE 1 SHOT PIN AT 16" O.C. STAGGERED FROM SIDE —TO —SIDE OF TRACK, OR EQUAL. 3. ALL METAL STUDS SHALL BE FASTENED TO TOP AND BOTTOM TRACKS WITH (2) MIN. #8-18 x 3/4" S.M.S. (0.164" DIA. SHANK x 5/16" HEAD), OR BETTER. 4. METAL STUD TRACK SHALL BE FASTENED TO 2x4 WOOD STUD FRAMING WITH (2) #12-16 x 13/4" HEX WASHER HEAD WOOD SCREWS (OR BETTER). — P.T. 2X SOLE PLATE OR LIGHT GAUGE 4"A Y2 x8" 18 GAGE HOT CLIP METAL TRACK STUD (SEE NOTE #2) GALV. STEEL PLATE SET IN — CONCRETE FLOOR SLAB PER PLAN ROOFING CEMENT. FASTEN PLATE WITH 2—X X1-1 GALV. PH SCREWS INTO PLYWC e... DECK & 2—X X1 X" GALV. PH SCREWS INTO 2X6. PROVIDE 0 ON EACH SIDE OF BLOCKING (STAGGER SPACING) NOTES: 1. PLACE FIRE BLOCKING CONSISTING OF 2x4 SOLID BLOCKING (OR CODE APPROVED EQUAL) BETWEEN ALL STUDS IN ALL INTERIOR PARTITION WALLS EXCEEDING 10'-0" IN HEIGHT. BLOCKING TO BE PLACED IN A CONTINUOUS ROW AT 8'-0" (+/—) ABOVE FINISHED FLOOR SLAB. 2. INTERIOR PARTITION WALLS CONSTRUCTED WITH LIGHT GAUGE METAL STUD SHALL BE CONSTRUCTED OVER 2X P.T. WOOD PLATE FASTENED AS NOTED IN THIS DETAIL. (NON -BEARING WALL) SCALE: 112" = V-0" :IN ACCORDANCE )DUCT APPROVAL IT BLOCKING -PTH OF BLOCKING TO )DATE PITCH OF ROOF) E GAGE FLOORAR SLAB SCALE: 1/2" = 1'-0" Y 1 STRAP FOR UPLIFT 1175# 2 STRAPS FOR UPLIFT UP T^ "'A" 3 ST 2 COURSES OF 8" BOND BEAM BLOC" (CEMEX/RINKER TYPE T81 OR EQ.) y (1)#5 BAR CONTINUOUS EACH COUR`. ALONG TOP OF WALL, FILLED SOLID GROUT HORIZONTAL BOND BEAM BARS WITH STD. 90- ACI HOOK (10" MINIMUM) (TYPICAL) 2 COURSE OF 8" BOND BEAM BLOCk (1)—#5 BAR CONTINUOUS FILLED SOL WITH GROUT t LLVA I ION VIEW SIMPSON HTSM16 COMMON PRE—ENGINEERED ROOF TRUSS (ONLY) (MISALIGNMENT OF GIRDER TRUSS CONNECTOR TO BE APPROVED BY ENGINEER) (4) Y4" x 2—Ya" TITEN MASONRY SCREWS SPACED EVENLY 0 LEAST 1—Y2" FROM TOP, AND INTO TOP CORD. (8) 10d X 3" NAILS STRAP MISALIGNMENT SCALE: N.T.S. .._....... ...... ;TD. 90' HOOK AT TOP GROUTED SOLID _STEPPED BOND BEAM DETAIL 4 1 CMU_WAL.L DETAIL a FRONT ENTRANCE S1 / ®\ 0 (6)-HOLES BOTH SIDES FOR THRU BOLTS 1/2" (30 KSI) STEEL TOP CAP 1 'ALL WELDED TOGETHER WITH F2 FIILETWELD CONTINUOUS ALL AROUND Y X 3" (30 KSI) STEEL COLUMN 1/2" THICK _ 16" X16" X Y2" THK (30 KSI) STEEL PLATE WELDED TO COLUMN WITH 1/2 FILLETWELD AND (6)- X 1211 ANCHOR BOLTS 14� SCALE: 2"=V-0" TRUSS BY TRUSS COMPANY'7111, (2nd BRG) FABRICATED STEEL POST CAP WITH (6)- 3!4" THRU BOLTS '/a FILLET WELD ALL AROUND COLUMN TO TOP CAP 3",X 3" (30 KSI) STEEL COLUMN "A" THICK 4" THICK (5000 :PSI) CONCRETE OVERPOUR WITH FIBERMESH 16" XI 6" X'/4" THK STEEL .PLATE WELDED TO COLUMN WITH FILLETWELD AND (6)- 3/4" X 12" ANCHOR BOLTS (2500 PSI) CONC. FOUNDATION SEE PLAN FOR SIZES AND SPECIFICATIONS ORAFCING SERVICES MOAN JAFFE, LLC PHONE: (772) 257-7942 www.,aens,,.sconsrow.rr,Na.com m a � m o d A A 0 W a A A z� 0 0 A a w 5 �a Q A o 0 0 zd V 1 I"� ftl L W A C 0 00 M O W w IS 04 A Wu V) h�l N H U 000 V1 O U PAUL WELCH INC. MECH-ELEC-CIVIL ENG 1984 SW ER-TMORE. ST. #114 PORT ST LUCIE, FL 34984 PAUL WELCH. P.E. FLA REG. No. 29945 JUN 1 1 2018 Date: SCALE: AS NOTED JOB No: 517-0639 s1 STUCCO OVER WIRELATH W/11GA. 2" NAILS w/ %"0 HEAD ® 6" O.C. OVER %" METAL RIB LATH ® 6" O.C. w/ (2LAYER OF 15# FELT OVER EACH FRAMING MEMBER) P.T. 2X BLOCKING WITH — STUCCO FINISH PER NOTES DECO TOP CAP. SEE TYPICAL EXTERIOR WALL AND FOOTING SECTION FOR ADDITIONAL INFORMATION PRE—ENGINEERED WOOD TRUSSES 024" O.C. (MAX. SPACING) "SIMPSON" STRAP PER TRUSS CONNECTOR SCHEDULE DBL 2X12 WOOD BEAM WITH N' CDX PLYWOOD SPACER GLUED AND NAILED WITH 10d NAILS AT 8" O.C. STAGGERED TOP AND BOTTOM BOTH WAYS "SIMPSON" HETA20 WITH (9)-16d NAILS EACH BEAM (2)—PER COLUMN \� '�#5 REBAR w/90 DEGREE HOOK DBL 2X BLOCKING (TYP.) 12"0 CONCRETE COLUMN WITH (2)—#5 BARS VERT. IN (3000 PSI) CONCRETE FILLED CELLS STUCCO FINISH STUCCO NOTE: EXTERIOR FRAME WALLS TO BE STUCCO OVER WIRELATH WITH 11 GA. 2" LONG NAILS WITH %"0 HEAD ® 6" O.C. OVER (2) LAYERS OF (15# FELT OR TYVAK BUILDING WRAP) OVER 1%2' COX PLYWOOD WITH 10D NAILDS TO STUDS ® 6" O.C. PERIMETER AND FIELD. DECO BOTTOM CAP (2) #5 IN FULLY GROUTED CELLS ADJACENT TO GARAGE DOOR OPENING AS SHOWN a D ° 2x6 P.T. (SYP) WOOD JAMB FASTENED w/ Wx5-X" (S.S. 304) HILTI KWIK BOLT 3 EXPANSION ANCHOR (OR EQUAL) w/ 2" SQUARE WASHER SPACED 016" O.C. MAX. STEEL TRACK BRACKETS TO BE FASTENED TO WOOD 2x6 BUCK w/ PER GARAGE DOOR MANUFACTURER'S SPECIFICATIONS (OR AS NOTED BELOW) OHGD TRACK BRACKETS TO P.T. BUCK 7' HIGH DOOR: (7) 5X6" x 1-5/e' LONG CORROSION RESISTANT HEX HEAD LAG SCREWS SPACED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. STUCCO CEMENT FINISH FILLED CELL AT JAMB BLOCK (TYP) CMU WATER RESISTANT COATING Li I �1� (SEE WATERPROOFING NOTE #1) q ° q' Q .. 4 e o °. ° �-10 P.T. WOOD FIRRING ALL (3) SIDES q CONTINUOUS WOOD TRIM #5 REBARS w/30" MIN. LAP SPLICE CORROSION RESISTANT FLASHING—� PER WATERPROOFING NOTE #2 — P.T. WOOD BUCK WITH SEALANT PER WATERPROOFING NOTE #4 AND ANCHORED TO 20"x2O" CONCRETE BLOCK BASE WITH APPLY PERIMETER SEALANT CAULK MASONRY PER BUCK ATTACHMENT NOTE. (2)—#5 BARS VERT. IN (3000 PSI) BETWEEN BUCK & WINDOW FRAME CONCRETE FILLED CELLS (SEE WATERPROOFING NOTE #5) SEE WATERPROOFING NOTE #6 FINISHED GRADE 2500 PSI) CONC. FOUNDATION SEE PLAN FOR SIZES AND SPECIFICATIONS STUCCO CEMENT FINISH FILLED CELL AT JAMB BLOCK (TYP) CMU WATER RESISTANT COATING Li 11 (SEE WATERPROOFING NOTE #1) ° q q a CORROSION RESISTANT FLASHING ° PER WATERPROOFING NOTE #2 a a ° tx3 P.T. WOOD FIRRING ALL (3) SIDES CONTINUOUS ° APPLY PERIMETER SEALANT CAULK " J \ SEE WATER PROOFING NOTE #6 BETWEEN BUCK &WINDOW FRAME \\\— (SEE WATERPROOFING NOTE #5) P.T. WOOD BUCK WITH SEALANT PER WATERPROOFING NOTE #4 AND ANCHORED TO 1 MASONRY PER BUCK ATTACHMENT NOTE. NOTE: WINDOW FRAME SHOULD BE COMPLETLY SEATED ON THE BUCK. IN NO INSTANCE SHALL THE FRAME OVERHANG THE BUCK ANCHOR WINDOW FRAME TO MASONRY IN STRICT ACCORDANCE WITH MANUFACTURE'S PRODUCT APPROVAL INSTALLATION REQUIREMENTS. 4 S2 STUCCO CEMENT FINISH CMU WATER RESISTANT COATING (SEE WATERPROOFING NOTE #1) APPLY PERIMETER SEALANT CAULK BETWEEN BUCK & WINDOW FRAME (SEE WATERPROOFING NOTE #5) CORROSION RESISTANT FLASHIN PER WATERPROOFING NOTE #2 2 ) WINDOW HEADER A JAMBS TYP. BUCK DETAIL 5 SCALE: N.T.S. Sj2 2 •Z�Z�1:3 ANCHOR DOOR JAMB HEADER TO MASONRY IN STRICT ACCORDANCE WITH MANUFACTURE'S PRODUCT APPROVAL INSTALLATION REQUIREMENTS. SCALE: N.T.S. FILLED CELL AT JAMB BLOCK (TYP) Li ° 10 P.T. WOOD FIRRING ALL (3) SIDES CONTINUOUS q ° q . WOOD TRIM P.T. WOOD BUCK WITH SEALANT PER WATERPROOFING NOTE #4 AND ANCHORED TO MASONRY PER BUCK ATTACHMENT NOTE. SEE WATERPROOFING NOTE #6 ANCHOR DOOR JAMB AND HEADER TO 2x BUCKS IN STRICT ACCORDANCE WITH MANUFACTURE'S PRODUCT APPROVAL INSTALLATION REQUIREMENTS. SCALE: N.T.S. CONTINUOUS FOAM INTERIOR AIR AND WATER SEALANT PER WATERPROOFING NOTE #6 MARBLE SILL MORTAR OR GROUT ,Y2" DRYWALL 10 RR FASTENERS AS REQUIRED BY WINDOW MANUFACTURER CORROSION RESISTANT FLASHING PER WATERPROOFING NOTE #2 CAULK SEAM AT WINDOW INSTALLATION (SEE WATERPROOFING NOTE #5) CMU WATER RESISTANT COATING (SEE WATERPROOFING NOTE #1) SET SILL IN FULL MORTAR BED STUCCO OR DECORATIVE CEMENTITIOUS COATING 8" C.M.U. -Y4" FURRING TO MASONRY WALL PRECAST CONCRETE WIND RESISTANT FLUSH SILL AS MANUFACTURERD BY CAST—CRETE (OR EQUAL) SCALE: N.T.S. WATERPROOFING NOTES: 1. PRIOR TO BUCK INSTALLATION TREAT THE MASONRY OPENING WITH A CMU WATER RESISTANT COATING TO SEAL THE WINDOW / DOOR CAVITY TO PREVENT IT FROM ABSORBING WATER. THE CMU WATER RESISTANT COATING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. THE APPLICATION OF THE CMU WATER RESITANT COATING SHALL INCLUDE THE ENTIRE SURROUND OF THE OPENING (SILLS, JAMBS, HEAD) AND RETURN WALLS OF THE OPENING 8" MINIMUM EACH DIRECTION. ALL CMU WATER RESISTANT COATINGS SHALL BE INSTALLED PRIOR TO BUCK INSTALLATIONS. 2. INSTALL BUCKS SO THAT THERE ARE NO EDGE GAPS EXCEEDING 1/8" BETWEEN BUCK AND MASONRY. 3. PRIOR TO BUCK INSTALLATION APPLY 3/8" NOMINAL DIAMETER BEAD OF SEALANT BETWEEN THE BUCK AND THE MASONRY TO PREVENT THE PASSAGE OF LIQUID BEHIND THE BUCK. COMPLETELY SEAL THE ENTIRE END OF THE WOOD BUCKS WITH SEALANT TO RESTRICT THE PASSAGE OF LIQUID THROUGH THE CUT ENDS AND THE ENTIRE EXTERIOR FACE AND RETURN SURFACE OF THE BUCK SHALL BE COATED WITH A LIQUID APPLIED WATER RESISTIVE COATING / SEALANT. 4. PROVIDE PAN FLASHING AT SILL OF WINDOW AND DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPED IN A MANNER TO DIRECT WATER TO THE SURFACE OF THE EXTERIOR WATER RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. INCORPORATE PAN FLASHING AT HEAD AND SILL AS WELL. PAN FLASHING SHALL BE CORROSION RESISTANT (OPTIONAL NOT REQUIRED IF ITEM #1-3 INSTALLED). 5. PROVIDE CONTINUOUS 3/8" BEAD OF SEALANT ON WINDOW / DOOR FRAMES AT ALL PERIMETER ON FRONT AND BACK SURFACE PRIOR TO WINDOW / DOOR INSTALLATION. 6. AFTER WINDOW/ DOOR INSTALLATION PROVIDE FOAM SEALANT BETWEEN THE BUCK (OR PRECAST SILL) AND THE WINDOW / DOOR TO ENSURE A WATER RESISTANT INTERIOR AIR SEAL AROUND THE ENTIRE PERIMETER. NOTE. WINDOW AND DOOR FENESTRATIONS SHALL BE IN ACCORDANCE WITH FMMA / AMA 200-9. CONTRACTOR SHALL SUBMIT FMMA / AMA 200-9 STANDARDS WITH PERMIT SUBMITTAL. BUCKS: • FOR WINDOWS, SGD, AND SWING DOORS USE 2X4, 2X6, 2X8, 1X6, 1X8, DOUBLE 1X6, OR DOUBLE 1X8 IS ACCEPTABLE. • ALL BUCKS MUST BE PRESSURE TREATED. • ALL BUCKS MUST COVER ENTIRE DEPTH OF THE DOOR/WINDOW JAMB. BUCK ATTACHMENT: • FOR 1 X BUCKS ATTACH TO CMU WALL WITH: 1 1/2" LONG CASE HARDENED COIL NAILS AT 4" FROM ENDS AND 12" O.C. OR 3/16" X 1 1/2" TAPCONS AT 4" FROM ENDS AND 12" O.C. OR 1/4" X 1 1/2" TAPCONS AT 4" FROM ENDS AND 12" O.C. • FOR 2 X BUCKS ATTACH TO CMU WALL WITH: 2 1/4" LONG CASE HARDENED COIL NAILS AT 4" FROM ENDS AND 12" O.C., OR 3/16" X 2 1/4" TAPCONS AT 4" FROM ENDS AND 12" O.C. OR 1/4" X 2 1/4" TAPCONS AT 4" FROM ENDS AND 12" O.C. • FOR DOUBLE 1 X BUCKS ATTACH FIRST COURS TO CMU WALL WITH: 1 1/2" LONG CASE HARDENED COIL NAILS AT 4" FROM ENDS AND 12" O.C. OR 3/16" X 1 1/2" TAPCONS AT 4" FROM ENDS AND 12" O.C. OR 1/4" X 1 1/2" TAPCONS AT 4" FROM ENDS AND 12" O.C. ATTACH SECOND COURS TO CMU WALL THRU FIRST COURSE WITH: 2 1/4" LONG CASE HARDENED COIL NAILS AT 4" FROM ENDS AND 12" O.C. OR 3/16" X 2 1/4" TAPCONS AT 4" FROM ENDS AND 12" O.C. OR 1/4" X 2 1/4" TAPCONS AT 4" FROM ENDS AND 12" O.C. DRAFTING SERVICES JOAN JA ,EL PHONE: (772) 231-7942 m � m a � o Q � a A A O 0 y�y F-� U N Q N F Q A z H ,H WP1 rn F a 00 W �M� Z x o� x O Q wUP, N 0 ArAW UNeu V71 aj 0 U PAUE WEECH INC. MECH-ELEC-CIVIL ENO 1984 SW BIETMORE ST. #114 PORT ST EUC , FE 34984 PAUE WELCH, P.E. FLA REO. No. 29945 FEB 15 2018 Date: SCALE: AS NOTED JOB No: 517-0639 S2 STUCCO OVER W/ 11 GA. 2" HEAD 0 6" 0 METAL RIB LA W/ (2 LAYER: OVER EACH F #5 REBAR W HOOK (4)—#5 VER1 T PER ELEV. #5 VERTICAL BARS WALL REINFORCING ABOVE WALL OPENINGS SHALL BE PROVIDED WITH A STD, ACI HOOK TIED TO LINTEL REINFORCING STEEL (TYPICAL) 4 TYPICAL #5 VERTICAL WALL REINFORCING ® 48" O.C, AND AS INDICATED ON THE PLANS SEE TYPICAL WALL SECTION FOR ADDITIONAL INFORMATION PRE— ENGINEERED WOOD TRUSSES ® 24" O.C. (MAX. SPACING) "SIMPSON" STRAP PER TRUSS CONNECTOR SCH. 8" CIVIL KNOCK OUT/BOND BEAM BLOCK w/(1)—#5 BAR IN (3000 PSI) CONCRETE 8" PRECAST LINTEL WITH (2)—#5 BAR IN (3000 PSI) CONCRETE FILLED CELL (SEE LINTEL SCHEDULE FOR MORE INFORMATION) 12" X 12" CONCRETE BLOCK COLUMN WITH (4) —#5 BARS IN (3000 PSI) CONCRETE FILLED CELLS STUCCO FINISH #5 REBAR W/ 30" MIN. LAP SPLICE FINISHED GRADE (2500 PSI) CONC. FOUNDATION SEE PLAN FOR SIZES AND SPECIFICATIONS A **PROVIDE (2)-ROWS OF BOND BEAM FOR WALLS WITH HEIGHT OVER 8'-1". SINGLE COURSE OF 8" BOND BEAM BLOCK (CEMEX/RINKER # T81 OR EQ.) ALONG TOP** REINFORCED WITH (1) #5 BARS CONTINUOUS IN EACH BLOCK LINTEL TYPE 8F16-1 B/1 T SECTION A —A SET PRE -CAST CONCRETE:. WINDOW SILL (SEE DETAIL 6, SHEET-S2) OR POUR IN PLACE CONC. SILL W/ (2) #4 BARS EXTENDED 6" (MIN.) INTO EACH SIDE JAMB BLOCK BEFORE GROUTING WALL CAVITIES (OR DRILL AND SET WITH 5" EPDXY EMBEDMENT) 8" CMU BLOCK WALL- REINFORCED AS NOTED ON THE PLANS AND INDICATED IN DETAILS (ALL VERTICAL BARS SHALL BE HOOKED INTO TOP BOND BEAM BLOCK) (1) #5 VERTICAL BARS -TYPICAL AT ALL WALL OPENINGS LESS THAN 8'-0" WIDE ALL OPENINGS 8'-0" WIDE AND LARGER SHALL HAVE (1) #5 BAR IN 2 ADJACENT BLOCK CELLS GROUTED SOLID (SEE PLANS FOR LOCATIONS) PRECAST CONCRETE LINTEL SCHEDULE: PROVIDE PRECAST REINFORCED CONCRETE "U" LINTEL AS MANUFACTURED BY CAST-CRETE (OR EQUAL) FOR ALL MASONRY OPENINGS OF THE SIZE AND REINFORCEMENT NOTED IN THE FOLLOWING LINTEL SCHEDULE: MASONRY WALL LINTEL SCHEDULE LINTEL DESIGNATION LINTEL LENGTH LINTEL TYPE SAFE GRAVITY LOAD APPLIED GRAVITY LOAD SAFE UPLIFT LOAD APPLIED UPLIFT LOAD COMPOSITE BEAM L-1 4'-6" 54" U-LINTEL 6133 250 2724 100 81`16-1B/1T L-2 5-10" 70" U-LINTEL 4360 250 2093 100 81`16-1B/1T L-3 7'-6" 90" U-LINTEL 6472 1100 3508 450 8F40-1B/1T L-4 4'-6" 54" U-LINTEL 6133 700 2724 300 81`16-1B/1T L-5 7'-6" 90" RECESSED 755 100 506 100 8RF6-OB/1T L-6 7'-6" 90" U-LINTEL 6472 700 3508 300 8F32-1B/1T L-7 17'-4" 208" PRESTRESSED 1849 800 754 350 8F29-1B/1T L-8 9'-4" 112" U-LINTEL 4705 650 2152 250 8F29-1B/1T L-9 4'-4" 52" RECESSED 10893 800 6183 350 8RF30-OB/1T L-10 5'-10" 126" U-LINTEL 7181 250 3897 100 8F29-18/1T L-11 4'-6" 54" U-LINTEL 10294 900 5077 370 8F29-1B/1T L-12 3'-6" 42" U-LINTEL 10394 350 6613 150 8F29-1B/1T L-13 3'-6" 42" U-LINTEL 4605 2000 2524 900 8F13-1B/1T L-14 7'-6" 90" RECESSED 1011 900 727 350 8F11-1B/1T L-15 4'-6" 54" U-LINTEL 4375 2000 1940 800 8F13-1B/1T L-16 6'-6°' 78" U-LINTEL 8825 550 4038 250 8F35-1B/1T L-17 5-10" 70" U-LINTEL 1238 1400 835 560 8F11-1B/1T L-18 3'-6" 42" U-LINTEL 11809 670 7636 350 8F37-1B/1T L-19 4'-6" 54" U-LINTEL 10294 1060 5077 450 8F29-1B/1T L-20 N/A - - - - - - L-21 14'-8" 176" U-LINTEL 2245 500 1440 250 8F24-1B/1T L-22 14'-0" 168" U-LINTEL 1697 964 1434 1197 8F24-18/1T L-23 7'-6" 90" U-LINTEL 5681 250 2571 250 8F24-1B/1T NOTE: WHEN LINTEL IS IN VARIOUS LOCATIONS, WORST CASE LOADING IS SHOWN NOTE: PROVIDE "CASTCRETE" PRE -CAST CONCRETE LINTEL AS NOTED ON PLANS TB-1 8" WIDE x 11" HIGH (3000 PSI) CONCRETE TIEBEAM FORMED AND POURED WITH (2)-#5 BARS CONTINUOUS TOP AND (2)-#7 BARS CONTINUOUS BOTTOM NOTE: 1. COMPOSITE BEAM DEPTHS SHOWN ARE MINIMUM REQUIRED, AND MAY BE INCREASED IN FIELD WITHOUT ENGINEER'S APPROVAL. 2. CALCULATED APPLIED GRAVITY LOAD AND APPLIED UPLIFT SHOWN ARE WORST CASE, ROOF TRUSS GIRDER LOADING HAVE BEEN CONSIDERED. 3. MASONRY CONTRACTOR TO VERIFY EACH MASONRY OPENING WIDTH AND HEIGHT PRIOR TO CONSTRUCTION. 4. LENGTHS OF LINTEL SHOWN ARE ACTUAL LINTEL SIZES (BEARING OF 4" EACH END MIN). SAW CUT BOTTOMS OF LINTEL MANUFACTURERS NOTCHES WHEN NEEDED TO EXTEND REBAR THROUGH LINTEL @ EACH SIDE OF OPENING. 5. ALL LINTELS SHALL BE SET TO PROVIDE A MINIMUM 4" BEARING ON MASONRY AT EACH END, UNLESS DETAILED ON THESE PLANS. 6. REINFORCED PRECAST "U" LINTELS SHALL BE MANUFACTURED WITH 5 1/2" LONG NOTCHES AT EACH END TO ACCOMMODATE PLACEMENT OF VERTICAL REINFORCING AND GROUT FILLING CELLS BELOW. 7. SEE TYPICAL LINTEL SECTION FOR CAST-CRETE DESIGNATIONS AND PLACEMENT OF REINFORCING STEEL. STEEL PLACED IN BOTTOM OF PRECAST LINTEL SHALL BE SET ON WIRE CHAIR TO PROVIDE 3/4" CLEARANCE OFF BOTTOM. 2 COURSES OF 8" BOND BEAM BLOC' (CEMEX/RINKER TYPE T81 OR EQ.) A (2)#5 BAR CONTINUOUS EACH COUR`. ALONG TOP OF WALL, FILLED SOLID GROUT HORIZONTAL BOND BEAM BARS WITH STD. 90' ACI HOOK (10" MINIMUM) (TYPICAL) ELEVATION VIEW 3TD. 90' HOOK AT TOP GROUTED SOLID 8" PRECAST CONC. LINTEL WITH (1) #5 BARS GROUTED SOLID WITH BOND BEAM BLOCK ABOVE PLACE #5 CORNER DOWELS INSIDE AND OUTSIDE OF VEF COLUMN BAR EXTENSION AS PLAN VIE F = FILLED WITH GROUT / U = UNFILLED QUANTITY OF #5 REBAR AT BOTTOM OF LINTEL CAVITY F r F1 6-1 B/lT 1—QUANTITY OF #5 REBAR AT TOP NOMINAL HEIGHT NOMINAL WIDTH TYPE DESIGNATION ,.. - hCD Q = a•. no \Z ¢ :• N m a. �o 4 7-5/8" ACTUA 8" NOMINAL WIDTH — #5 REBAR CONTINUOUS ALONG TOP OF WALL 1-1/2" CLEAR — 8" BOND BEAM BLOCK (RINKER/CEMIX #T81 OR EQ.) — GROUT SOLID (3000 psi) _#5 REBAR AT BOTTOM 3/4" CLEAR OFF 8F16-1B/1T PRECAST LENTIL FIELD CUT LINTELS TO MITER END AND CUT BOTTOM TO ALLOW EXTENSION OF 3 COLUMN VERTICAL BARS THROUGH LINTEL (1) #5 REBAR CONT. ALONG TOP OF BEAM aw 3 r� m O o a�w m R 0z z �o I N � R #5 REBAR AT BOT GROUT SOLID (3000 psi) 8" BOND BEAM BLOCK (CEMEX/RINKER # T81 OR EQUAL) #2 STIRRUP (ACI TYPE S1) ® 8" O.C. NTEL CAVITY 8" PRECAST LINTEL LINTEL TYPE 8F16-1B/1T MODIFIED AS SHOWN 2 TYPICAL REINFORCEMENT PLACEMENT AT WINDOW OPENINGS 3 CM WALL DETAIL FRONT ENTRANCE WAY _________ 4 PRECA T LINTEL DETAIL_ COVERED POW Sri SCALE N.T.S. 3 SCALE: N.T.S. 53 SCALE: N.T.S. DRAFTING SERVICES JOAN JAFFE, L C PHONE: p72) 23I-7942 H � v o 3 rl a A Q A 3 u z A A a E z 0 zu In H A N 7 F a A 6 z I0=11 v 1 fTl H U � rzl W� z C V00 Arn 04 O�wQ Z A PP4a 0 w� H O Aau (~ U � x Boa as P a u vl 0 U PAUL WELCH INC. MECH-ELEC-CIVIL ENS P84 SW BILTMORE ST. K] PORT ST LUCIE, FL 3498 PAUL WELCH, P.E. FLA REG. No. 29945 FEB 1 5 2018 Date: SCALE: N.T.S. JOB No: 517-0639 S3 FLOOD LIGHT — g og(MOTION SENSOR) ■ o ■ \ \ ■ yyyypp yyp METER ■ ■ \ \ FLOOD LIGHT \ (MOTION SENSOR) DISC. •• ■ ■ ■ ■ ■ ■ ■ ■ ° \\ ■ ■ ■ ■ ■ ■ ■I \ ■ ■ ■ ■ ■ ■ ■ ■ ■ •• C — GFI K 1�NLR�AAER zNLBER(FIELD—LOCATE 50 CFM AEPAEGFI FLOOD LIGHT=---_�/L 0 I CEILING MEDA LION) f� I ------ DISC. (MOTION SENSOR) --'' —\\// '-t° ■ I LOCATION OF BASE 50 CFM I / Cam.\ 1 I1I \I \/\ I \/\ /\\■■■• I /X• \\_�_I/II I�1/1 WI \ —�'\/-/\ --\/-/\ \J\ \ - I /\-/ /\ /I/ \\/ \ _\ FOR — \ALL � ® SPEAKERS, o�I ((FIELD —LOCATE WIRES, CAT6 ,\ I /F\—I,E\L— D II —LR O—CA—TE fDI CEILING MEDALLION) CLG MEDAON) S . I �\ ■ I\ (FIELD FIELD \l\?LOCATE) \ \�1 0SrGENERALI 4/GENERATOR] GFAFF ETLW/TERWCH MAXX IR I \ \ \\ ■\`\■ \\\ \\/ \\ �\.l \ \ \ _ \ _\\ \�\ \ \ 1'f/ /11 F /111 o XAH#13000ACFM 18" EXHAUST FANJ(VENT To ATTIC) 42 / F_ K XETUR II T (LED RECESS LIGHTS) //—/ — / // //' ' / / ■l\(Xl ■1J ■ \ \ \ \ \\ \ \ \ \ttl/ / / / /rlIrIl/ / ■\/• • GWFpI ••■■• iIIIiIr/III / ® AHDIz �---------I-------------------- L_J GFL— DT 42 AFF GO OPENER GO OPENER 220V L BOX PREPARE PRENRE LJL \\ TO UNDER CAB. — — — — — IN\\ — — — — — _LIGHTING T VENTAMATIC\ ADJUSTABLE THERMOSTATR L% \FI LOCATION FI � \ 2aAFF(2PRE WIRE AAT EBO LOCATION 0 '> F — — — — — — — — — — — 71 FIELD LOCATE •o \`,v L1 J \----------1 ^TOPRE-WRE OUTLETS�¢ IGF\ Oo �FIIELD4LOCATE BOTH SIDES OF DRIVEWAY ENTRANCE FLARE) CLNG MEDALLION) �` PAN za J LED RECESS LIGHTS) / II \ II II II (\ \\ I ■\ I \ \ \ \ 1 \ FD�Li1\ � �\ R IR GFI CELNGMEDLION) 6'/LIELD—LOCATE " 10I-4CENG MEDALLION)/ (LED RECESS\LIGHTS) —_ --------- — \\----�/ /// A r� / I HB ` J \\ \ (LED RECESS LIGHTS) to \ _ \ R a2 LIGHTINGs\°F�T TO / UGHTINGR CAB. _ _ \\ 1 \ \ f —4 1 G \ \/ / / I 0 loll ti FLOOD LIGHT \`CJ \r/ FLOOD LIGHT A\ (MOTION SENSOR) IN IN / (MOTION SENSOR) I I K I I I I � II\ ■ // // I� II \\ I I / / � � / III j I ■ �•\I// � / \/J_ _ I / I L\//�//\/\ J7 K o �'C�� (3)—#3/0, #4, 2"C FIIELD—LOCATE CENG MEDALLION) / / /I 1 \ / I IWP ■ 1 I I \ \ / IGFI I 200 200 SUB- I I I \ 2 MTS PANE PANE I I / I ✓ \ zo/Y" 20/2 I I I ■ __ / I /��•"q�� ` \ / O1 1 I MOP 10 1H I I 50 C+ GFI UNDER / / I I COUNTER / I I F ELD—LOCATE �� O \ FI / \ /CEILING MEDALLION) / / \ \ 7 1■ - `� `Y \ \\ I .�IN\ \\ / I// I Fn. ELECTRIC LOAD LC'S PER NEC 4218 sq. ft. x 3VA (GENERAL LIGHTING) 12,654 VA TWO 20A APPLIANCE CKTS 3000 LAUNDRY 1500 DRYER 5000 RANGE 12000 WH 4500 DW 1200 WP TUB (OPTION) 1200 REFRIGERATOR 1200 PUMPS 7200 MISC. 11000 TOTAL 60,454 VA FIRST 10 KW @100% 10000 REMAINDER 040% 20,181.6 TOTAL 30,181.6 A/C HEAT ® 100% 15300 TOTAL 45,481.6 VA TOTAL/240V 190 AMPS USE 200 AMP SERVICE PANEL (3)—#3/0, #4, 2"C I �\ G j I C� y (LED RECESS LIGHTS) \ \ / \\ • I o / \ \ I PH DISC XFMR SIZE BY OWNER / /T\ — �I �\ \ FIELD LOCATE (NOT IN GARAGE) ■ // / \� — — — — — — - I LJ \\ \\ I / I 4 CU GRND TIED TO BLDG I / / / / \ \ \ _ L — — — J \ ■ I 1 STEEL, CWP, AND DRIVEN GROUND I / • • ' / / \ — — Fl ® JETTED TUB ■ ■ (3) #3/0 THW IN 2° CONDUIT / / r \ _ L I \� — IQTI��M VIGFI (UG OR OVERHEAD ELECTRICAL SERV.) ■ II ELECTRICAL RISER '/ ,' `\ ,-mot - — j�/�� V I `/ \ J / / \7J 50 CFM USE ALL CU WIRE NO SCALE I / (FIELD —LOCATE / I PREAWIRE CEILING MEDALLION) \\---/ %%// // ■ I � J---------------+--� I �_� � \ � ■ // —PR_ L--------JGFI i HB ELECTRICAL SYMBOL LEGEND SWITCH $ DIRECT WIRE ® LIGHT FIXTURE 3-WAY SWITCH $3 THERMOSTAT (D CEILING MOUNTED \J 4-WAY SWITCH $4 PHONE/CAT6 LIGHT FIXTURE /PULL SWITCH DIMMER SWITCH $° TV JACK i' RECESSED LIGHT 120V OUTLET SMOKE DETECTOR sD (ALL LED) A�vLP, HALF -HOT OUTLET (p DETECTOR MONOXIDE co 0 RECESSED LIGHT VAPOR PROOF �I0 I GAS CONNECTION EXHAUST FAN A 4 FLOOD LIGHT C� GFI OUTLET PUSH BUTTON O WP GFI OUTLET OR DOOR CHIMES a CEILING FAN with x GFI ALARM PAD o LIGHT QUAD OUTLET PANEL E= A/C DISCONNECT METER 17�1 GARAGE DOOR = J GDa —L FLUORESCENT CEILING x OPENER .j LIGHT FAN FAN W/LIGHT 0 SPEAKER —El JUNCTION BOX SPEAKER CONTROL Q GARBAGE DISP. P LIGHT FIXTURE WALL MOUNTED \ ij� - DRAFTING SERVICES JOAN JAPFE, LLC PHONE: (7722) 237 7979 a mw co v � 0 o Oti � ti a y v, W W F L6 Q u z a A A u w 0 a u OQ FW1 F+�1 Q 0. z W Z U � W vI 00 A C W xM� U Q wU ~ q"�W 0 �lI F� NaU x 20o� � Wa PAUL WELCH INC. MECH-ELFC-CIVIL ENG 1994 SW HILTMORE ST. #114 PORT ST LUCIE, PI. 34984 PAUL WELCH, P.E. PLA REG. No. 29945 1 FEB 15 me Date: SCALE: 1/4" = P-O" JOB No: 517-0639 E1 m 162 CFM 14x8x8 0 143 CFM oI L I I 12x8x7 I 2x12 G 117 CFM I I 12x6x7 1 45 CFM ETUI 8x4x5 I I AH F Q1, ..�M%--L I I ;z—1 I I 12x12 12"0 1 0"0 1 14"0 w 6"0 41 CFN 16"0— — — — — — — — — — — 71 8x8x8 8x8x8 ° I — — — — — — — 182 CFM 182 CFM a I 12x12x8 I 16 247 CFM I 120 SCFM I I I I ��\ /L ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ / \ \ 180 CFM ■ // / R A 22x22 \ 14x8x8 / 4 120 CFM // ■ ■ ■r — 19 CFM ® 1 8x4x5 19 CFM M 10x6x7 — — — — — — — — / I � so♦ / I I I I I I I I I I 10x10x7 I -- I 134 CFM 1ox1ox8 171 CFM 2"0 12x8x8 163 CFM -& EFM— -� \ I I I 1 `+ L___J 1 3 1 8 8L4 1 15 CFM L J 10x10x7 141 CFM 0 M I DRAFTING SERVICES IOAN JAFF , L c KPH' OANE: (772) 237-794 �N � rl V r a ti UW 7a G U W Q a G 0 zu m 0 A Q z Date: SCALE: 1/4" = 1,4, JOB No: 517-0639 115'-9" 2'-0" 26'_7" 16'-2" 68'-0" 3'-0" 3'-10" x 14' LONG 4" THICK MIN. POURED 4" THICK SLAB WITH THICKEN CONCRETE UTILITY SLAB WITH THICKEN EDGES EDGES WITH FIBERMESH REINFORCED WITH 66-W1.41.4 WWM VERIFY SIZE n Ll, ■■ ■ ■ ■ ■ ■■ O O v F_ — F1 P2 1" 7'-1" 17'-0" ■ ■ ■ --- ■ ■ ■ ■ ■ TYP. 8" CONCRETE ■ I ■ ■ — — ■ ■ z ■ ----- ■ ■oil■ ■ ■ ■ ■ ■ ■ ■ ■ ■ BLOCK WALL L ° pp o (SEE SHEET—A5/DETAIL 1) III Ft ��WATER FEED LOCATION FOR AQUASANA HOUSE FILTER F3 OI • • / ro N III P2 1 P2 \ ■ I N • i' N 4" PVC PIPE SLEEVE BELOW FLOOR SLAB 1 0 ■ I Ft ® FOR COMPRESSOR SUPPLY AND RETURN PIPE ETUR ■ Pz II 11 1,1 YI AH #1 46'-0„ BOTTOM EDGE ■ I ■ O CV p F6 1 ■ N ■ i l \ BEARING P2 RECESS SLAB 4 w I( I P4 POST ETUR BELOW FINISH FLOOR d q F3 I SLOPE I I 0 26'-8" 19'-10" 17' 3" 3'-6" 2'-61' P2 I 1/ /F'T cO N H #2 I, --� cql — — 44'-4.' ■ O Go 0 / I L J ") POUR IN PLACE COLUMNS ® OPN'N/JAMB WHERE TOP OF SLAB —III— J� 66' X 66" X 36" DEEP (2500 PSI) 011 O POUR IN PLACE COLUMNSWALL WALL OPN'N/JAMB WHERE ; I 2'-8 CONC. PAD FOOTING WITH #5 BARS AT 7 INDICATED (TYP.) I" O.C. BOTH WAYS TOP AND BOTTOM 4" INDICATED (TYP.) /11OTTOM — #5 VERT DOWEL REINF. C� N ALL WALL OPN'N/JAMB AND ■■■■■ ■ ■ ■ •• N I F1 @ 4'-0" P2 O.C. MAX (TYP.) �a " ° HB 8'-0" 16'-0" 2'-0" 8'—O" 3 0„ 1 N Ft I I 38'-4" ■ I TYPICAL 8" CONCRETE BLOCK WALL W/#5 BARS AS INDICATED 0'—O" P2 I I _00 REINFORCED TOP OF SLAB HB I WITH CONTINUOUS TOP OF WALL BOND � \ I I ro BEAM USING (2) 8" "H" BLOCK w/(1) r' #5 BAR IN EACH GROUTED SOLID \ A • F5 P2 III ALIGN w/ROOF TRUSS GIRDER _ 0 - - — — — — — — _ — — — I ra •• --- I 1n (SEE TRUSS LAYOUT PLAN FOR ALIGNMENT) ■ - ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ , F4 c ■ o I P2 F4 P2 1/2" EXPANSION JOINT IM I0 III IN \ 4" THICK SLAB (2500 psi min.) REINFORCED w/ 6x6 - W1.4xW1.4 WOVWN WIRE MESH I 2'-10" F4 Pz SLOPE ` (OR FIBERMESH) ON 6 MIL VAPOR BARRIER OVER F5 —4" SLOPE N) CLEAN COMPACTED TERMITE TREATED h PREPARED SUBGRADE P2 I i /a' DTI m ■ F1 gyp\, I rim P2 O�PG F4 O \ P2 io I\ — RECESS SLAB 4 BELOW FINISH FLOOR ■ M ■ 0)9� I M 6'-1" N ISLOPE •I I� O r) -4" C�] F, I 0 P2 I ¢ 40'-3"x41' CONCRETE SLAB P2 3'-2" 2'-2" 5'-0" N (PROVIDE FOOTINGS PER SCREEN _ Lo ENCLOSURE ENGINEER) I I I • • 6'-2y" I� / ■ ■ L-- •� _8 ■ I•� � N � •� -4' o I ■ DOWEL ROD REPAIR NOTES I` �� / O■ N N ■ IN THE EVENT STEEL HAS BEEN INADVERTENTLY_ OMITTED FROM DOWN POUR LOCATIONS, DRILL 6" I� /� I ® F� 00 TOP OFOSLAB 2 P2 INTO CONCRETE (NO CLOSER THAN 3-4" FROM 10 co �I EDGES AND 5" FROM ENDS OF CAP WALLS). I ■ SLOPE REMOVE DUST PER MFG'S INSTRUCTIONS AND USE I F5 P2 I t/ /FT co LO TWO PART EPDXY TO ANCHOR #5 REBAR IN PLACE. I`I I USE EITHER HILTI C-100 OR SIMPSON EPDXY —TIE. TYPICAL 8" CONCRETE BLOCK WALL ■ REINFORCED W/#5 BARS AS INDICATED O WITH CONTINUOUS TOP OF WALL BOND BEAM USING (2) 8" "H" BLOCK w/(1) ■ ■ 4� o #5 BAR IN EACH GROUTED SOLID Ft F1 - \ P2 P2 i+7 ♦r F1 _ ■ ■ ■ ■ ■ ■ ■ ■ HB • N P2 4'-10" 8 —2° 3'-2" 43'-8" 3'-10" 2'-0" 28'-8" 3'-6" 52'-0" 861-2" DRAFTING SERVICES LOAN IAFPE, L C PHONE: U72) 237-7942 www.Txew.su�consTu".v'r,rvc.roM m ° m v � o W � x 7 F A I PAUL WELCH INC. MECH-ELEC-CIVIL ENG 1984 SW EILTMORE ST. #114 PORT ST LUCIE, FL 34984 PAUL WELCH, P.E. FLA REG. No. 29945 t FEB 15 2018 Date: SCALE: 1 /4" = P-0" JOB No: 517-0639 9_1 V " MASONRY AL, SEE PLAN �8" MASONRY WALL, SEE PLAN / #5 REBAR @48" O.C. (MAX.) & AS SHOWN ON PLANS #5 REBAR ®48'" O.C. (MAX.) & AS SHOWN ON PLANS ✓/ 10" VERIFY W/ Yq"XS" WIDE BLOCK RECESS DOOR MANUR oM � 4' THICK (MIN.) POURED 4" THICK (MIN.) POURED CONC. (2500 PSI MIN.) N w 7— CURB w < 4" THICK (MIN.) POURED 4" THICK (MIN.) POURED CONC. (2500 PSI MIN.) FINISHED FLOOR CONC. (2500 PSI MIN.) 717 w > CONC. (2500 PSI MIN.) FINAL GRADEy, -„� FINAL GRADE \T7 7 �i�; .i ,p jr \ ri 6x6—W1.4xW1.4 WWM �rri �.'. 12" MIN. EMBEDMENT r 6x6—W7.4xW1.4 WWM 12" MIN. EMBEDMENT BELOW EXISTING GRADE : r r (OR FIBERMESH) ;���� �,�� BELOW EXISTING GRADE '��� 3" MIN. (OR FIBERMESH) (2) #5 CONTINUOUS REBAR 1'-6" 6" 3" MIN. CLEAR ( THICKENED EDGE 1'-6" (2) #5 CONTINUOUS REBAR 1'-6" 6" CLEAR COVER (TYP.). THICKENED EDGE MIN. FOOTING WITH (2) #5 MIN. FOOTING WITH (2) #5 6X6—W1.4xW1.4 WWM BARS CONTINUOUS 6X6—W1.4xW1.4 WWM BARS CONTINUOUS DOUBLE WITHIN 3 FT. DOUBLE WITHIN 3 FT. FROM FOOTING (TYP) FROM FOOTING (TYP) (OR FIBERMESH) (OR FIBERMESH) EXTERIOR WALL FOOTING FOOTING AT OHGD / r� l CURB SECTION �y FOOTING CF SCALE: 3l8" = 1'-W. F2 SCALE: 3/8" = 1'-0" BEARING SCALE: 3/6" = 7'•ll" SCALE: 3/8" = 1'-8" 0 M 3 Y2" POURED CONC. PORCH SLAB 12" MIN. EMBEDMENT —,- BELOW EXISTING GRADE �f (2) #5 CONTINUOUS REBAR EXTERIOR STEP F5 BEARING MASONRY WALL, SEE PLAN i REBAR 048" O.C. (MAX.) & AS SHOWN ON PLANS Q"X8" WIDE BLOCK RECESS 4" THICK (MIN.) POURED CONC. (2500 PSI MIN.) F. F. A I iv (TYP.) 6X6—W1.4xW1.4 WWM DOUBLE WITHIN 3 FT, FROM FOOTING (TYP) (OR FIBERMESH) 3/8" = 1'-0" 4" THICK (MIN.) POURED 7-5/8" CURB CONC. (2500 PSI MIN.) VAR..ES 8" Z N Z w y w FINAL GRADE •-mot r�r�i� r�`�,Y~� 12" MIN. EMBEDMENT BELOW EXISTING GRADE 6X6—W1.4xW1.4 WWM (2) #5 CONTINUOUS REBAR 1'-6" g" DOUBLE WITHIN 3 FT. MIN. FROM FOOTING (TYP) (OR FIBERMESH) 47 SHOWER CURB SCALE: 3/8" = 1'•0" C.O. \ T VTR V 2" 3 2. TUBt WC L 3" 2x4 FRAMED NON —BEARING WALL SEE TYP. DETAIL FOR Y2" DIA.00" A.B. 024" O.C. CONNECTION TO FOUNDATION MAX. W/7" MIN. EMBED. 2" (MIN.) P.T. SOLE PLATEr---,k- �3 Y2' THICK (MIN.) POURED OILF. F. CONC. (2500 PSI MIN.) 6X6—W1.4xW1.4 WWM (OR FIBERMESH) #5 BARS CONTINUOUS F61 INTERIOR STEP NON -BEARING SCALE: 318" _ J VTR / V 2„ / LAV. 2 WC \2" TUB N. 2" \ 2" / 2.. / / 1 Y2" AUTO VENT AIR GAP DW A CONCRETE FOUNDATION NOTES 1. SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS. 2. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3" SUBGRADE PREPERATION NOTES 1. THE AREA WITHIN THE LIMITS OF THE FOUNDATION SHALL HAVE ALL VEGETATION, TOP SOIL AND FOREIGN MATERIAL REMOVED. 2. CLEAN FILL SAND AND OR GRAVEL FILL, FREE OF VEGETATION AND FOREIGN MATERIAL, MUST BE PLACED TO DESIGN SUBGRADE LEVEL AND COMPACTED TO ASSURE UNIFORM SUPPORT OF THE FLOOR SLAB. 3. SUBGRADE COMPACTION SHALL BE ACHIEVED BY MEANS AND METHODS DETERMINED BY THE RESPONSIBLE CONTRACTOR. SOIL DENSITY TESTING BY INDEPENDENT SOILS 2" VTR TESTING FIRM SHALL BE REQUIRED TO INSURE PRESCRIBED SOIL DENSITIES ARE J ACHIEVED. 4. AFTER FOOTING EXCAVATION, AND FORMING, CONTRACTOR SHALL RECOMPACT SUBGRADE SOILS USING SUITABLE VIBRATORY MECHANICAL COMPACTOR. THE PLUMBING LEGEND AND ABBREVIATIONS UPPER 16 INCHES OF SOILS UNDERLAYING THE WALL FOOTINGS SHOULD HAVE A MINIMUM DENSITY OF 95% OF THE MAXIMUM DRY UNIT DENSITY AS DETERMINED BY MODIFIED PROCTOR METHOD FOR THE EXISTING SOILS. IN -PLACE SOIL DENSITY — — SANITARY SOIL PIPE (BELOW FLOOR SLAB) LT TESTS SHOULD BE PERFORMED IN ACCORDANCE WITH ASTM D-2922, AT A FREQUENCY DETERMINED BY THE SOIL TECHNICIAN TO VERIFY UNIFORMITY OF THE — — — — — — DRY VENT LINE BRANCH ABOVE CEILING (RE —VENT) UNDERLYING SOIL DENSITY, PRIOR TO PLACING CONCRETE. 5. SUBBASE COMPACTION FOR THE FLOOR SLAB FILL MATERIAL SHALL BE UNIFORMLY SOIL PIPE VENT THROUGH ROOF COMPACTED TO A MINIMUM DENSITY EQUAL TO 95% OF THE MAXIMUM DRY UNIT VTR DENSITY OF THE FILL AS DETERMINED BY MODIFIED PROCTOR METHOD IN ACCORDANCE WITH ASTM D-1557. WC WATER CLOSET (TOILET) 6. CONCRETE SLABS ON GRADE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER WITH A MINIMUM THICKNESS OF 6 MILLS, INSTALLED WITH LAPPED JOINTS LAV. LAVATORY \ NOT LESS THAN 6 INCHES AND CONTINUOUSLY TAPPED WITH HIGH DENSITY \ POLYETHYLENE ADHESIVE TAPE. c;HR SHOWER TUB TUB \ S SINK 3" VTR \ J � \ KS KITCHEN SINK LT LAUNDRY TUB 2" \ WASH \ pW DISH WASHER LT 3„ \ C.O. CLEANOUT —� C.O.T.G. CLEANOUT TO GRADE 0 3" \ " — — / / / 3j / / 2" VTR / / / 2 / \ 4" (MIN.) BUILDING SEWER 3„ — — — — TO ON —SITE SANITARY SEWER LIFT STATION C.O.T.G. � 2 VTR J \ V .2" \/ 2„ 2„ 2" VTR J SHR WC V 2 / 2" VTR �_ 3„ TUB J 3" SANITARY SOIL/WASTE11 r DRAIN PIPE (EXACT LOCATION i / TO BE FIELD LOCATED) / 11, WASTE, DRAIN AND VENT RISER DIAGRAM SHR SCALE: NTS 4" S LAV. WG / LAV. 3" LAV. DRAFTING SERVICES IOAN IAFB, LLC PHONE: p92) 239-0942 >1 j � I z 3u P4 PAUL WELCH INC. IECH-ELEC-CIVIL Ell S4 SW SILTMORE ST. # ORT ST LUCM, FL 3491 PAUL WELCH, P.E. FL, RE . No. 29945 JUN 1 12018 Date: SCALE: AS NOTEI JOB No: 517-0639 PZ 0 0 0 0 0 A 0 Hatch Legend NO 141111 DRAFTING SERVICES SOAN IAPPL. I T C PHONE: (712) 237-7"2 NW �Y.'t'P6P81➢16COA.9]D6APLMO.COM H a � �Uwy z Gvy� A Q U d LI 7 re: F d Q d z PAUL WELCH INC. l IMCH-EEEC-CTVE. F.NG )84 SW BMTMORE ST. #114 PORT ST LUCIE, FL 34984 PAUL WELCH, P.E. PEA REG. No. 29945 FEB 1' 5 2018 Date: SCALE: 3/16" = P-0" JOB No: 517-0639 1-0191 Lml TRUSS CONNECTOR SCHEDULE TRUSS ID HEARING POINT TRUSS ACTUAL UPLIFT CONNECTOR ID CONNECTOR UPLIFT DESIGN FASTENERS NOTES T04 1ST & 2ND 1067 (1)-HETA20 1810 (8) - Ad T10 1ST 3412 (1)-MGT 3965 (22) - 10d & (1) - 5/0" A.B. 2 3 T10 2ND 3fi78 (1)-FGTR 5000 L8 _SS 1 4 z 9 & 2 1 2" z 5,. TITEN HD TI1 1ST 1225 (1)-HETA20 1810 (8) - 16d TI1 2ND 11435 FAB. CAP 12000 SEE DETAIL SEE "DETAIL AT TRUSS TI1 2ND BEG" T11 3RD 2308 (1)-MGT 3965 (22) - 10d & (1) - 5/8" A.B. 2 3 T20 1ST 3290 (1)-MGT 3965 (22) - 10d & (1) - 5/0" A.B. 2 3 T20 2ND 1594 (1)-HETA20 1810 (8) - 16d T31 & T62 1ST & 2ND 1798 (1)-HETA20 1810 (8) - 16d T63 2ND 5765 (i)-HDUB 7570 210 - - 7 8" SD3 A.B.1 4 z 2 1/2- & 2 T84 1ST & 2ND 2790 (I)-MGT 3065 (22) - LOd & (1) - 5/8" A.B. 2 3 VALLEYS CONT. 100 # Ply ( ) MTS 16 1000 1 (14) - 10d z 1 1/2" �1 1 STRAP AT EACH END AND AT 24" O.C. LESALL S OTHERS EACH <1450# (i)-METAIB2 100 (7) - 10d z 1-1/2" AT CBS HEARING LESALL OTHERS STUN Ot 00i EACH <1000/ (1)-MTS 16 1000 (14) - IDd z 1-1/2" AT FRAME HEARING TRUSS COMPANY paw 60u9gg LAYOUT DATE 1 10/19/2017 C DA � 1 02/05/18 10d x 1 1/2" = SIMPSON'S SUPPLIED EQUIVALENT NAIL FOR COMMON 10 PENNY WEIGHT NAIL SDS = SIMPSON'S STRONG -DRIVE 1/4' DIA. WOOD SCREW (OFT EQUAL) OVALLEY TRUSSES MAY BE ATTACHED WITH SIMPSON VTCR W/(4)-#9 SO x 2 J1" TO SUPPORTING TRUSS AND (3)-#g SO x 1 71" TO VALLEY TRUSS IN LIEU OF MTS16 AS STATED. VTCR SHALL BE INSTALLED AT EACH END AND 24' O.C. MAX. O USE SIMPSON EPDXY STRONG TIE SYSTEM WITH 12" MIN. EMBEDMENT FOR ANCHOR BOLTS (A.B.) O(1)-FGTR WITH (18)-SDS Y4" x 3" & (2) Y2" x 5' TITEN HD MAY BE USED IN LIEU OF CONNECTOR AS SPECIFIED NOTE: 1. DESIGN UPLIFT REACTIONS HAVE BEEN DETERMINED AND PROVIDED BY THE TRUSS MANUFACTURER'S SHOP DRAWINGS (BUILDERS FIRST SOUCE.; JOB NO. 1149533; LAYOUT DATE10/19/17; CUT -SHEET DATE: 02/05/18) AND REVIEWED BY THIS STRUCTURAL ENGINEER FOR DETERMINATION OF THE TRUSS CONNECTOR TYPE AND ALLOWABLE LOADS NOTED IN THE TRUSS TO WALL CONNECTOR SCHEDULE. 2. LATERAL SHEAR FORCES (F1) AND TRANSVERSE LOADS (F2) f,'N TRUSS CONNECTORS HAVE BEEN EVALUATED IN ACCORDANCE WITH THE 2017 FBC-RESIDENTIAL CODE. 3. ALL TRUSS TO PERIMETER 8" CMU WALL CONNECTORS SHALL BE META 12; UNLESS DESIGNATED OTHERWISE ON THE ROOF FRAMING PLAN. 4. MINIMUM 4" EMBEDMENT WITH MINIMUM EDGE DISTANCE OF 2" REQUIRED FOR META STRAPS CAST -IN -PLACE. 5. TRUSS ANCHOR -META 16 STRAP SHALL BE PROVIDED WITH "TSS" MOISTURE BARRIER SEAT. 6. ANCHORS, HANGERS, AND TIE STRAPS AS SHOWN IN THE ABOVE SCHEDULE ARE IDENTIFIED ON THE ROOF FRAMING PLAN. SUBSTITUTION OF APPROVED EQUAL OR BETTER ANCHORS, HANGERS AND TIE STRAPS FOR THE SPECIFIED ALLOWABLE LATERAL & UPLIFT LOADS ARE ACCEPTABLE. 7. THE SIMPSON STRONG -TIE CONNECTOR ALLOWABLE LOAD VALUES SHOWN IN THE ABOVE SCHEDULE ARE THE C-2013 PUBLISHED VALUES BASED ON WOOD TRUSSES FABRICATED USING SOUTHERN YELLOW PINE AND INCLUDE AN APPLIED 1/3 STRESS INCREASE FOR WIND LOAD DURATION ONLY, IN ACCORDANCE WITH NDS ALLOWABLE STRESS DESIGN PERMITTED FOR WOOD OR FASTENERS IN WOOD. 8. PROVIDE SUITABLE PRE -FORMED OR LIQUID APPLIED MOISTURE BARRIER BETWEEN BOTTOM CHORD OF ROOF TRUSS AND TOP OF MASONRY WALLS, WHEN BARRIER IS NOT PROVIDED WITH TRUSS CONNECTOR. 9. SIMPSON STRONG TIE ANCHORS AND STRAPS PRODUCTS SHALL BE HOT DIPPED (H.D.) ZINC -GALVANIZED PER ASTM AIB23 TO G90 AS MEASURED BY ASTM A653, OR BETTER. 10. ALL CARBON STEEL ANCHOR BOLTS, FASTENERS, AND NAILS, UNLESS OTHERWISE SPECIFIED, SHALL BE HOT DIPPED ZINC -GALVANIZED IN ACCORDANCE WITH ASTM A1653 STANDARDS. 11. ANCHOR BOLTS (A.B.) SHALL CONSIST OF "J" BOLTS WITH MIN. EMBEDMENT OF 10" CAST -IN -PLACE AT TIME OF WALL GROUTING WORK. SETTING ACHOR BOLTS AFTER WALL CONSTRUCTION SHALL CONSIST OF ALL THREADED ROD (ATR) DRILLED AND ANCHORED WITH HILTI HIT RE-500 INJECTION EPDXY SYSTEM (OR SIMPSON EPDXY -TIE (ET) EPDXY ADHESIVE) IN STRICT ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. MINIMUM EMBEDMENT DEPTHS SHALL BE AS FOLLOWS: ROOF ATTACHMENT / ASSEMBLY TILE: ENTEGRA ROOF TILE (GALENA SPANISH 'S"FL#7804.1 UNDERLAYMENT: POLLYGLASS TU PLUSS FL# 5259.1 MAXIMUM UPLIFT DESIGN PRESSURE FOR ATTACHMENT PER NOA: Attachment Resistance: Mf = —37.8 FT —LB (OF MOMENT) Restoring Moment: Mg = 5.74 FT —LB (OF MOMENT) Aerodynamic Multiplier: A = 0,235 FT3 Pmax = Mf — M = (-37.8 — 5.74) = —185 PSF A ( 0.235) ATTACHMENT REQUIREMENTS: ZONE 1, 2 &3 ATTACHMENT AS FOLLOWS: TILE INSTALLATION: PROVIDE 27G 3M— 2 COMPONENT FOAM ROOF TILE ADHESIVE AH-160 PER TILE WITH A 4"TILE HEADLAP FOR ALL TILES. ALSO PROVIDE (1) — #8 SCREW PER TILE EVERY 3RD TILE IN EVERY 5TH COURSE FASTENERS LOCATED A MINIMUM OF 2 1'A"FROM HEAD OF TILE. UNDERLAYMENT INSTALLATION: UNDERLAYMENT INSTALLATION: PROVIDE POLLYSTICK TU PLUS SELF —ADHERED OVER EXISTING DECK. PROVIDE OVER PLYWOOD JOINTS DESIGN PRESSURE —90 PSF ALL WORK TO BE IN COMPLIANCE WITH PRODUCT APPROVAL (FL#7804.1) & MANUFACTURER'S SPECIFICATIONS, RAS 118, RAS 119, RAS 120 AND THE FLORIDA BUILDING CODE 20,' ANCHOR DIA. DRILL HOLE DIA. (MAX.) EMBEDMENT DEPTH (MIN.) W, �1is" 12" DETAIL 1 SCALE: N.T.S. PLYWOOD SHEATHING NAILING SCHEDULE LOCATION NAIL SIZE/TYPE EDGEFIELD INOTES SPACING SPACING WALL Z SHEATHING 0 N ALL gd COMMON 6" D.C. 6" O.C. (15/32") WALL ZONES E 4" O—C. O ® 8d Ring Shank 4" O.C. (OVERHANGS) ROOF Z SHEATHING (19/32") N O 8d Ring Shank 4" O.C. 6" O.C. E (D 8d Ring Shank 6" O,C. 6" O.C. IN Ce 8d RING —SHANK NAILS SHALL HAVE THE FOLLOWING MINIMUM DIMENSIONS: 1. 0.113—INCH NOMINAL SHANK DIAMETER 2. RING DIAMETER OF 0.012 OVER SHANK DIAMETER 3. 16 TO 20 RINGS PER INCHES 4. 0.280 INCH FULL ROUND HEAD DIAMETER 5. 2Y2"—INCH NAIL LENGTH EAVE I ",,,,I ROOF SHEATHING ATTACHMENT REQUIREMENTS ZONE Q NAILS AT 6" O.C. PERIMETER AND 6" O.C. FIELD ZONE NAILS AT 6" O.C. PERIMETER AND 6" O.C. FIELD ZONE ® NAILS AT 4" O.C. PERIMETER AND 6" O.C. FIELD ROOF SHEATHING SHALL BE 19 32- 'THICK COX PLYWOOD ROOF SHEATHING FASTENED TO ROOF FRAMING WITH 8d RING —§HANK NAILS (PER FRC803.2.3.1) SPACED PER ZONE DESIGNATIONS AS SHOWN ABOVE. A= 5' PLAN "PLAN VIEW") A= 5 FEET SCALE: N.T.S. TRUSS NOTES 1. ALL ROOF TRUSSES TO BE DESIGNED BY TRUSS COMPANYS ENGINEER. 2 CONTRACTOR TO PROVIDE SAINT DESIGN & FORENSICS" INC. AND BUILDING DEPARTMENT MTN ENGINEERED TRUSS DRAWINGS BEFORE INSTALLING TRUSSES. & CONTRACTOR TO VERIFY ALL DUSTING ROOF CONDITIONS, AND DIMENSIONS BEFORE ORDERING AND INSTALLING TRUSSES 4. TRUSS TO TRUSS CONNECTIONS TO BE PROVDED BY TRUSS COMPANY. & SEE TRUSS CONNECTOR SCHEDULE FOR TRUSS TO WALL CONNECTIONS. DRAFTING SERVICES JOAN JAFPE, LLC PHONE: (772) 237-7942 m � � rn m O )" U Q a n A 3 A W U z W w 0 z� H H A Q 0 z v i W rT1 iEoz U 0w Z �0 A C) W 0� �. W U P+ 0 AaW 0 <� Qx�( 000 vl 0 . 0 PAUL WELCH INC. MECH-ELEC-CIVIL ENG 1984 SW BILTMORE ST. #114 PORT ST LUCIE. FL 34984 PAUL H WELC. P.E. FLA REG. No. 29945 Ff9 Date: 1' 5 2D18 SCALE: N.T.S. JOB No: 517-0639 R2