Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNED BY FORM R405-2017 St Lucie County FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MAHFOOD RESIDENCE Street: 7832 SADDLEBROOK DRIVE City, State, Zip: PORT ST LUCIE , FL, 34986 Owner: ! Design Location: FL, Fort Pierce Builder Name: Permit Office: CITY OF PORT ST LUCIE Permit Number: Jurisdiction: County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans)I 9. Wall Types (3755.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=9.0 3465.10 W b. Frame - Wood, Adjacent R=13.0 290.67 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (4218.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 4218.00 ft2 6. Conditioned floor area above grade (ft2) 4218 b. N/A R= ft2 Conditioned floor area below grade (ftZ) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(686.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 180 a. U-Factor: Sgl, U=0.65 686.00-ft2 b. Sup: Attic, Ret: Attic, AH: Garage 6 140 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 42.0 SEER:16.00 i b. Central Unit 29A SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a. Electric Strip Heat 27.0 COP:1.00 SHGC: b. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 4.379 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (4218.0 sqft.) Insulation Area a. Electric Cap: 40 gallons EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 4218.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.163 Total Proposed Modified Loads: 121.23 PASS Total Baseline Loads: 128.95 I I hereby certify that the plans and specifications covered by Review of the plans and ,O -TJiE Sr,' this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance ' with the Florida Energy Code. mr�,'<.;;:€i ', •�"„ O PREPA D Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 V I herebycertify that this building, as e i ned, is in compliance fY 9. 9 P lorida Energy Code. Florida Statutes. '�?• 5 G'Op H,E:�R�' W�witha AGENT BUILDING OFFICIAL: DATE: Z DATE: - Compliance requires certi ation by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE C SPY 1/24/2018 9:51 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 8 FORM R4n5-2n17 PROJECT Title: MAHFOOD RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 4218 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate An gle: 0 Street: 7832 SADDLEBROOK Permit Office: CITY OF PORT ST LUCIE Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: PORT ST LUCIE , Family Type: Single-family FL, 34986 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5' % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 2464 27831.7 2 AHU 2 1754 1 18221.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 KITCHEN 423 4695.3 Yes i 0 1 Yes Yes Yes 2 MEDIA ROOM 287 4018 No 0 1 Yes Yes Yes 3 GYM 474 4313.4 No 0 1 Yes Yes Yes 4 CLST 22 200.2 No 0 1 Yes Yes Yes 5 BATH 3 66 600.6 No 0 1 Yes Yes Yes 6 MEDIA HALL 16 145.6 No 0 1 No Yes Yes 7 CLST 3 22 200.2 No 0 1 Yes Yes Yes 8 BEDROOM 3 225 3150 No 0 1 1 Yes Yes Yes 9 BATH 2 99 900.9 No 0 1 Yes Yes Yes 10 BEDROOM2 225 I 3150 No 0 1 1 Yes Yes Yes 11 CLST 2 30 273 No 0 1 Yes • Yes Yes 12 HALL 36 327.6 No 0 1 No Yes Yes 13 LAUNDRY 63 573.3 No 0 1 No Yes Yes 14 FAMILY ROOM 476 5283.6 No 0 1 Yes Yes Yes 15 DINING ROOM 225 2497.5 No 0 1 Yes Yes Yes 16 STUDY 225 2498 No 0 1 Yes Yes Yes 17 FOYER 115 1046.5 No 0 1 Yes Yes Yes 18 LIVING 301 3341.1 No 0 1 Yes Yes Yes 19 WET BAR 72 655.2 No 0 1 No Yes Yes 20 HALF BATH 36 327.6 No 0 1 Yes Yes Yes 21 M HALL 25 227.5 No 0 1 No Yes Yes 1/24/2018 9:51 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 8 FORM R405-2017 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 M WIC 2 52 473.2 No 0 1 No Yes Yes 23 M TOILET 24 218.4 No 0 1 No Yes Yes 24 MASTER BATH 246 2238.6 No 0 1 Yes Yes Yes 25 M WIC 1 54 491.4 No 0 1 Yes Yes Yes 26 MASTER BEDROO 379 4206.9 I No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation KITCHEN 8!1 8 ft 0 423 ft2 -_-- 1 0 0 2 Slab -On -Grade Edge Insulation MEDIA ROOM I 33.2 ft I 0 287 ft2 __e 1 0 0 3 Slab -On -Grade Edge Insulation GYM 43.2 ft 0 474 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulation CLST 2 ft 0 22 ft2 __-_ 1 0 0 5 Slab -On -Grade Edge Insulation BATH 3 I 6 ft 0 66 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulation MEDIA HALL 11 ft 0 16 ft2 1 0 0 7 Slab -On -Grade Edge Insulation CLST 3 2 ft 0 22 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulation BEDROOM 3 23 ft I 0 225 ft2 1 0 0 9 Slab -On -Grade Edge Insulation BATH 2 9 ft 0 99 ft2 __e 1 0 0 10SIab-On-Grade Edge Insulation BEDROOM2 15 ft 0 225 ft2 __� 1 0 0 11Slab-On-Grade Edge Insulation CLST 2 2 ft 0 30 ft2 1 0 0 12SIab-On-Grade Edge Insulation HALL 11 ft 0 36 ft2 -__- 1 0 0 13SIab-On-Grade Edge Insulation LAUNDRY 1 ft 0 63 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation FAMILY ROOM 16 ft 0 476 ft2 1 0 0 15SIab-On-Grade Edge Insulation DINING ROOM 13.6 ft 0 225 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation STUDY 16.6 ft 0 225 ft2 ---_ 1 0 0 17SIab-On-Grade Edge Insulation FOYER 17 ft 0 115 ft2 1 0 0 18SIab-On-Grade Edge Insulation LIVING 13 ft 0 301 ft2 __e 1 0 0 19SIab-On-Grade Edge Insulation WET BAR 1 ft 0 72 ft2 __-- 1 0 0 20SIab-On-Grade Edge Insulation HALF BATH 6ft 0 36 ft2 -_-- 1 0 0 21SIab-On-Grade Edge Insulation M HALL 1 ft 0 25 ft2 ____ 1 0 0 22SIab-On-Grade Edge Insulation M W IC 2 1 ft 0 52 ft2 ____ 1 0 0 23SIab-On-Grade Edge Insulation M TOILET 1 ft 0 24 ft2 __e 1 0 0 1/24/2018 9:51 AM EnergyGauge® USA-'FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 8 i=(1RI A RenF_7017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 24SIab-On-Grade Edge Insulation MASTER BATH 39.9 ft 0 246 ft2 ___ 1 0 0 25SIab-On-Grade Edge Insulation M W IC 1 9 ft 0 54 ft2 1 0 0 26SIab-On-Grade Edge Insulation MASTER BEDRO 43.3 ft 0 379 ft2 1 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel tile 47171ft2 I 0 ft2 Medium 0.6 No 0.9 No 20 26.6 ATTIC IRCC # Type Ventilation Vent Ratio (1 in) Area RBS 1 Full attic Unvented 0 4218 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) KITCHEN 20 Blown 423 ft2 0.1 Wood 2 Under Attic (Unvented) MEDIA ROOM 20 Blown 287 ft2 0.1 Wood 3 Under Attic (Unvented) GYM i 20 Blown 474 ft2 0.1 Wood 4 Under Attic (Unvented) CLST 20 Blown 22 ft2 0.1 Wood 5 Under Attic (Unvented) BATH 3 20 Blown 66 ft2 0.1 Wood 6 Under Attic (Unvented) MEDIA HALL 20 Blown 16 ft2 0.1 Wood 7 Under Attic (Unvented) CLST 3 20 Blown 22 ft2 0.1 Wood 8 Under Attic (Unvented) BEDROOM 3 I 20 Blown 225 ft2 0.1 Wood 9 Under Attic (Unvented) BATH 2 20 Blown 99 ft2 0.1 Wood 10 Under Attic (Unvented) BEDROO,M2 20 Blown 225 ft2 0.1 Wood 11 Under Attic (Unvented) CLST 2 20 Blown 30 ft2 0.1 Wood 12 Under Attic (Unvented) HALL 20 Blown 36 ft2 0.1 Wood 13 Under Attic (Unvented) LAUNDRY 20 Blown 63 ft2 0.1 Wood 14 Under Attic (Unvented) FAMILY ROOM 20 Blown 476 ft2 0.1 Wood 15 Under Attic (Unvented) DINING ROOM 20 Blown 225 ft2 0.1 Wood 16 Under Attic (Unvented) STUDY 20 Blown 225 ft2 0.1 Wood 17 Under Attic (Unvented) FOYER 20 Blown 115 ft2 0.1 Wood 18 Under Attic (Unvented) LIVING 20 Blown 301 ft2 0.1 Wood 19 Under Attic (Unvented) WET BAR 20 Blown 72 ft2 0.1 Wood 20 Under Attic (Unvented) HALF BATH 20 Blown 36 ft2 0.1 Wood 21 Under Attic (Unvented) M HALL 20 Blown 25 ft2 0.1 Wood 22 Under Attic (Unvented) M WIC 2 20 Blown 52ft2 0.1 Wood 23 Under Attic (Unvented) M TOIL'ET 20 Blown 24 ft2 0.1 Wood 24 Under Attic (Unvented) MASTER BATH 20 Blown 246 ft2 0.1 Wood 25 Under Attic (Unvented) M W IC 1 20 Blown 54 ft2 0.1 Wood 26 Under Attic (Unvented) MASTER BEDRO 20 Blown 379 ft2 0.1 Wood 1/24/2018 9:51 AM EnergyGauge® USA'- FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 8 FORM R405-2017 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space - Ft - 1 SW Exterior Concrete Block - Int Insul KITCHEN 9 2 0 11 1 22.2 ft2 0 0 0.6 0 2 W Exterior Concrete Block - Int Insul KITCHEN 1 9 2 10 11 1 31.4 ft2 0 0 0.6 0 3 NW Exterior Concrete Block - Int Insul KITCHEN 9 4 0 11 1 44.3 ft2 0 0 0.6 0 4 W Exterior Concrete Block - Int InsuMEDIA ROO 9 3 7 14 0 50.2 ft2 0 0 0.6 0 _ 5 NW Exterior I Concrete Block- Int InsuMEDIA ROO 9 9 0 14 0 126.0 ft2 0 0 0.6 0 6 N Exterior I Concrete Block - Int InsuMEDIA R00 9 3 7 14 0 50.2 ft2 0 0 0.6 0 7 NE Exterior I Concrete Block - Int InsuMEDIA ROO 9 17 0 14 0 238.0 ft2 0 0 0.6 0 8 SW Exterior Concrete Block - Int Insul GYM 9 22 0 9 1 199.8 ft2 0 0 0.6 0 9 W Exterior Concrete Block - Int Insul GYM 9 3 7 9 1 32.5 ft2 0 0 0.6 0 _ 10 NW Exterior Concrete Block - Int Insul GYM 9 14 0 9 1 127.2 ft2 0 0 0.6 0 11 N Exterior Concrete Block - Int Insul GYM I 9 3 7 9 1 32.5 ft2 0 0 0.6 0 12 NE Exterior Concrete Block - Int Insul CLST 9 2 0 9 1 18.2 ft2 0 0 0.6 0 13 NE Exterior Concrete Block - Int Insul BATH 3 9 6 0 9 1 54.5 ft2 0 0 0.6 0 14 NE Exterior Concrete Block - Int Insul CLST 3 9 2 0 9 1 18.2 ft2 0 0 0.6 0 15 SE Exterior Concrete Block - Int InsuBEDROOM 3 9 4 0 14 0 56.0 ft2 0 0 0.6 0 16 NW Exterior Concrete Block - Int InsuBEDROOM 3 9 4 0 14 0 56.0 ft2 0 0 0.6 0 17 NE Exterior Concrete Block - Int InsuBEDROOM 3 9 15 0 14 0 210.0 ft2 0 0 0.6 0 _ 18 NE Exterior Concrete Block - Int Insul BATH 21 9 9 0 9 1 81.8 ft2 0 0 0.6 0 _ 19 NE Exterior Concrete Block - Int InsuBEDROOM2 i 9 15 0 14 0 210.0 ft2 0 0 0.6 0 20 NE Exterior Concrete Block- Int Insul CLST 21 9 2 0 9 1 18.2 ft2 0 0 0.6 0 21 SW Exterior I Concrete Block - Int InsLFAMILY ROO 9 16 0 11 1 177.3 ft2 0 0 0.6 0 22 SE Exterior Concrete Block - Int InsuDINING ROO 9 10 0 11 1 110.8 ft2 0 0 0.6 0 23 S Exterior Concrete Block - Int InsuDINING ROO 9 3 7 11 1 39.7 ft2 0 0 0.6 0 24 E Exterior Concrete Block- Int Insul STUDY 9 3 7 11 1 39.7 ft2 0 0 0.6 0 25 SE Exterior Concrete Block- Int Insul STUDY 9 13 0 11 1 144.1 ft2 0 0 0.6 0 26 SE Exterior Concrete Block- Int Insul FOYER 9 18 0 9 1 163.5 ft2 0 0 0.6 0 27 NW Exterior Concrete Block - Int Insul LIVING 9 13 0 11 1 144.1 ft2 0 0 0.6 0 28 NW Exterior Concrete Block - Int InsuIHALF BATH 9 6 0 9 1 54.5 ft2 0 0 0.6 0 29 E Exterior Concrete Block - Int InsuMASTER 'BA 9 4 6 9 1 40.9 ft2 0 0 0.6 0 30 SE Exterior Concrete Block - Int InsuMASTERiBA 9 12 0 9 1 109.0 ft2 0 0 0.6 0 31 S Exterior Concrete Block - Int InsuMASTER, BA 9 4 6 9 1 40.9 ft2 0 0 0.6 0 32 SW Exterior Concrete Block - Int InsuMASTER BA 9 15 0 9 1 136.3 ft2 0 0 0.6 0 33 NE Exterior Concrete Block - Int InsuMASTER BA 9 4 0 9 1 36.3 ft2 0 0 0.6 0 34 SW Exterior Concrete Block- Int Insul M W IC,1 9 9 0 9 1 81.8 ft2 0 0 0.6 0 _ 35 SW Exterior Concrete Block - Int InsuMASTER BE 9 20 0 11 1 221.7 ft2 0 0 0.6 0 _ 36 W Exterior Concrete Block - Int InsuMASTER BE 9 4 3 11 1 47.1 ft2 0 0 0.6 0 37 NW Exterior Concrete Block - Int InsuMASTER BE 9 6 0 11 1 66.5 ft2 0 0 0.6 0 38 N Exterior Concrete Block - Int InsuMASTER BE 9 12 1 11 1 133.9 ft2 0 0 0.6 0 _39 NE Garage Frame -Wood LAUNDRY 13 1 0 9 1 9.1ft2 0 0 0.6 0 _40 SE Garage Frame - Wood DINING ROO 13 24 9 1 218.0ft2 0 0 0.600000 0 41 NE Garage Frame - Wood DINING ROO 13 7 9 1 63.6 ft2 0 0 0.600000 0 1/24/2018 9:51 AM EnergyGauge® USA; FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 8 FORM R405-2017 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SW Insulated HALF BATH None .39 2 6 6 8 16.7 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SW 1 TIM Low-E Single Yes 0.65 0.25 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 2 W 2 TIM Low-E Single Yes I 0.65 0.25 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 3 NW 3 TIM Low-E Single Yes 0.65 0.25 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 4 W 4 TIM Low-E Single Yes 0.65 0.25 N 10.0 ft2 2 ft 0 in 1 ft 4 in None None 5 N 6 TIM Low-E Single Yes 0.65 0.25 N 10.0 ft2 2 ft 0 in 1 ft 4 in None None 6 NE 7 TIM Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 7 SW 8 TIM Low-E Single Yes 0.65 0.25 N 48.0 ft2 2 ft 0 in 1 ft 4 in None None 8 W 9 TIM Low-E Single Yes 0.65 0.25 N 10.0 ft2 2 ft 0 in 1 ft 4 in None None 9 NW 10 TIM Low-E Single Yes i 0.65 0.25 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 10 N 11 TIM Low-E Single Yes 0.65 0.25 N 10.0 ft2 2 ft 0. in 1 ft 4 in None None 11 NE 13 TIM Low-E Single Yes 0.65 0.25 N 9.0 ft2 2 ft 0 in 1 ft 4 in None None 12 NE 17 TIM Low-E Single Yes 0.65 0.25 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None 13 NE 17 TIM Low-E Single Yes 0.65 0.25 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 14 NE 18 TIM Low-E Single Yes 0.65 0.25 N 9.0 ft2 2 ft 0 in 1 ft 4 in None None 15 NE 19 TIM Low-E Single Yes 0.65 0.25 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 16 SW 21 TIM Low-E Single Yes 0.65 0.25 N 18.0 ft2 2 ft 0 in 1 ft 4 in None None 17 SW 21 TIM Low-E Single Yes 0.65 0.25 N 40.0 ft2 14 ft 0 in 1 ft 4 in None None 18 SE 22 TIM Low-E Single Yes 0.65 0.25 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 19 SE 22 TIM Low-E Single Yes 0.65 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 20 S 23 TIM Low-E Single Yes 0.65 0.25 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 21 S 23 TIM Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 22 E 24 TIM Low-E Single Yes 0.65 0.25 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 23 E 24 TIM Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 24 SE 25 TIM Low-E Single Yes 0.65 0.25 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 25 SE 25 TIM Low-E Single Yes 0.65 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 26 SE 26 TIM Low-E Single Yes 0.65 0.25 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 27 SE 26 TIM Low-E Single Yes 0.65 0.25 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 28 SE 26 TIM Low-E Single Yes 0.65 0.25 N 48.0 ft2 2 ft 0 in 1 ft 4 in None None 29 NW 27 TIM Low-E Single Yes 0.65 0.25 N 48.0 ft2 14 ft 0 in 1 ft 4 in None None 30 E 29 TIM Low-E Single Yes 0.65 0.25 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 31 E 29 TIM Low-E Single Yes 0.65 0.25 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 32 SE 30 TIM Low-E Single Yes 0.65 0.25 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None 33 SE 30 TIM Low-E Single Yes 0.65 0.25 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 34 S 31 TIM Low-E Single Yes 0.65 0.25 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 35 S 31 TIM Low-E Single Yes 0.65 0.25 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 36 SW 35 TIM Low-E Single Yes 0.65 0.25 N 24.0 ft2 2 ft 0 in 1 ft 4 in None None 37 W 36 TIM Low-E Single Yes 0.65 0.25 N 10.0 ft2 2 ft 0 in 1 ft 4 in None None 38 NW 37 TIM Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 1/24/2018 9:51 AM EnergyGauge® USA-' FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 8 Ff7RM R40S-2017 WINDOWS Orientation shown is the entered, Proposed orientation. v # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 39 40 N 38 TIM Low-E Single N 38 TIM Low-E Single Yes Yes 0.65 0.25 N 10.0 ft2 2 ft0 in 1 ft4 in None 0.65 0.25 N 48.0 ft? 14 ft 0 in 1 ft 4 in None None None GARAGE i # Floor Area Ceiling Area ,Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 1104 ft2 1104 ft2 I 31 ft 9 ft 13 INFILTRATION # Scope Method SLA I CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000486 5I372.9 294.97 554.73 .3545 7 HEATING SYSTEM i # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Strip Heat/ Electric Strip Heat/ None None COP:1 27 kBtu/hr 1 COP:1 27 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split SEER: 16 42 kBtu/hr 1260 cfm 0.8 1 SEER: 16 29.4 kBtu/hr 882 cfm 0.8 2 sys#1 sys#2 HOT WATER SYSTEM System Type SubType Location I EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name I Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS # -- Supply -- Location R-Value Area -- Return -- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 2 Attic 6 180 ft2 Attic 6 140 ft2 Attic Attic 18 ft2 Default Leakage Garage (Default) c(Default) c 14 ft2 Default Leakage Garage (Default) c(Default) c 1 1 2 2 1/24/2018 9:51 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 7 of 8 FORM R405-2017 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling Jan Heat in Jan Feb Feb Mar Mar Apr A r i May May Jun Jun Jul Jul AugSep Auge Oct Oct Nov Nov Dec Dec Venting Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 1 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 178 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 1/24/2018 9:51 AM EnergyGauge® USA FlaRes2017 Section R405.4.1 Compliant Software Page 8 of 8 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: MAHFOOD RESIDENCE Builder Name: Street: 7832 SADDLEBROOK DRIVE Permit Office: CITY OF PORT ST LUCIE City, State, Zip: PORT ST LUCIE , FL, 34986 Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT I AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be 'sealed. Ceiling/attic I The air barrier in any dropped ceiling/soffit shall be aligned with the insulation in the barrier be The insulation in any dropped ceiling/soffit and any gaps air shall sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls shall The junction of the top plate and the top of exterior walls shall be sealed. be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. I Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom i to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed: Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wirin . Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. in addition, inspection or iog walls shall be in accordance with the provisions of ICC-400. 1/24/2018 9:52 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. 7832 SADDLEBROOK DRIVE, PORT ST LUCIE, FL, 34986 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.25 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: New (From Plans) 9. Wall Types Insulation Area Single-family I a. Concrete Block - Int Insul, Exterior R=9.0 3465.10 ft2 b. Framer Wood, Adjacent R=13.0 290.67 ft2 1 c. N/A R= ft2 3 d. N/A R= ft2 10. Ceiling Types Insulation Area No a. Roof Deck (Unvented) R=20.0 4218.00 ft2 4218 b. N/A R= ft2 c. N/A R= ft2 Area 11. Ducts R ft2 686.00 ft2 a. Sup: Attic, Ret: Attic, AH: Garage 6 180 b. Sup: Attic, Ret: Attic, AH: Garage 6 140 ft2 l 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. N/A R= c. N/A R= 12. Cooling systems kBtu/hr Efficiency ft2l a. Central Unit 42.0 SEER:16.00 I b. Central Unit 29.4 SEER:16.00 ft2 13. Heating systems kBtu/hr Efficiency 4.379 ft. a. Electric Strip Heat 27.0 COP:1.00 b. Electric Strip Heat 27.0 COP:1.00 0.250 I Area 14. Hot water systems 4218.00 ft l a. Electric Cap: 4 EF: 0.98 ft21 ft2 b. Conservation features None 15. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above ener y saving features which will be installed (or exceeded) in this home before final inspection. therwise, a new EPL Display Card will be completed based on installed Code compliant f tures. Builder Signature: Date: Address of New Home: ��, �� Sa d p 1)1'�, City/FL Zip: Ct � *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/24/2018 9:52 AM EnergyGauge® USA-!FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 Pro ect Summa Job: wrightsoft® , Date: JANUARY24, 2018 AHU 1 By: QUICK CALCS, INC. I 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS a,\OL.COM For: MAHFOOD RESIDENCE 7832 SAD DLEBROOK DRIVE, PORT ST LUCIE, FL 34986 Notes: Weather. Fort Pierce, FL, US Winter Design Conditions I Summer Design Conditions Outside db 42 OF I Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20735 Btuh Structure 21964 Btuh Ducts 7459 Btuh Ducts 9269 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28194 Btuh Use manufacturers data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 29672 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4341 Btuh Ducts 2965 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 2464 2464 Equipment latent load 7306 Btuh Volume (W) 27832 27832 Air changes/hour 0.25 0! 14 Equipment total load 36978 Btuh Equiv. AVF (cfm) 118 163 Req. total capacity at 0.70 SH R 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER AIR CONDITIONING Model Cond CA16NA0420000A AHRI ref Coil FX4DNF049 AH RI ref 7894072 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 8.1 kW Sensible cooling 29400 Btuh Heating output 27695 Btuh Latent cooling 12600 Btuh Temperature rise. 18 OF Total cooling 42000 Btuh Actual air flow 1400 cfm Actual air flow 1400 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. � ,+ wrightsoft 2018-Jan-24 09:49:18 -- RightSuite® Universal 2017 17.0!08 RSUD8101 �C` E:\Documnets\Wrightsoft WACIMAHFOOD RESIDENCE.rup Calc = MJ8 Front Door faces: SE Page 1 Pro ect Summa Job: -�+ wrightsoft® AH+U 2 � Byte: JANUARY 24, 2018 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax Email: QUICKCALCS@AOL.COM For. MAHFOOD RESIDENCE 7832 SADDLEBROOK DRIVE, PORTST LUCIE, FL 34986 i i Notes: Design Information i Weather Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF I Inside db 75 OF Design TD 28 OF I Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20279 Btuh Structure 15594 Btuh Ducts 4608 Btuh Ducts 6492 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuti Blower 0 Btuh Piping 0 Btuh Equipment load 24887 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 20982 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3168 Btuh Ducts 1744 Btuh Heating Coolin�gg Central vent (0 cfm) 0 Btuh Area (ft2) 1754 1754 Equipment latent load 4912 Btuh Volume (ft3) 18221 18221 Air changesthour 0.32 0.17 Equipment total load 25894 Btuh Equiv. AVF (cfm) 97 52 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary , Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER AIR CONDITIONING Model Cond CA16NW0300000A AHRI ref Coil FX4DNF037L AHRI ref 7692728 Efficiency 100 EFF Efficiency 13.5 EER, 16 SEER Heating input 7.2 kW Sensible cooling 20580 Btuh Heating output 24469 Btuh Latent cooling 8820 Btuh Temperature rise 23 °F Total cooling 29400 Btuh Actual air flow 980 cfm Actual air flow 980 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. l- wrightsoft- 2018 Jan-24 09:49:18 .,:— RightSulteO Universal 2017 17.0.08 RSU08101 Page 2 ACC�* EADocumnetslWrightsolt WACIMAHFOOD RESIDENCE.rup Calc = MJ8 Front Door faces: SE Duct System Summary Job: - wrightsoft® y Date: JANUARY 24, 2018 AHU 2 By: QUICK CALLS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fare 772-466-6796 Email: QUICKCALCS AOL.COM For: MAHFOOD RESIDENCE 7832 SADDLEBROOK DRIVE, PORT ST LUCIE, FL 34986 Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) ' H tin Coolin ea g 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 980 cfm i 9 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 980 cfm 209 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk DINING ROOM c 4062 140 180 1.000 8.0 Ox 0 VIFx 39.9 115.0 st2 HALF BATH h 792 31 19 1.000 5.0 Ox 0 VIFx 67.6 135.0 st5 LIVING c 3863 134 171, 1.000 8.0 Ox0 VIFx 34.6 115.0 st2 •TOILET c 70 1 3 1.000 4.0 OxO VIFx 62.3 135.0 st5 • WIC 1 h 910 36 15, 1.000 4.0 Ox0 VIFx 62.3 135.0 st5 • WIC 2 c 184 3 8i 1.000 4.0 Ox0 VIFx 55.2 135.0 Sty MASTER BATH h 5127 202 141 1 1.000 7.0 Ox 0 VIFx 68.9 135.0 st5 MASTER BEDROOM h 3526 139 134� 1.000 7.0 OxO VIFx 73.9 135.0 st5 MASTER BEDROOM -A h 3526 139 134- 1.000 7.0 Ox 0 VIFx 62.1 135.0 st5 STUDY c 3679 152 163; 1.000 8.0 Ox 0 VIFx 42.3 115.0 st2 WET BAR c 227 3 10 1.000 4.0 Ox0 VIFx 56.9 135.0 sty Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 980 980 1.000 702 16.0 0 x 0 VinlFlx st5 Peak AVF 554 465 1.000 705 12.0 0 x 0 VinlFlx st2 wrightsoft' Rlght.SuiteO Universal 2017 17.0.08 RSU08101 2018-Jan-24 09:49:22 Page 3 EADocumnetslWrightsoft HVACIMAHFOOD RESIDENCE.rup Calc = MJ8 Front Door faces: SE Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 Ox 0 980 980 0 . 0 0 0 Ox 0 VIFx wri htsoft° 2018-Jan-24 09:49:22 JaAlt 9 Right -Suite® Universal 2017 17.0.08 RSU08101 Page 4 k EADocumnetslWrightsoft WACIMAHFOOD RESIDENCE.rup I Calc = MJ8 Front Door faces: SE