HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNED
BY
FORM R405-2017 St Lucie County
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MAHFOOD RESIDENCE
Street: 7832 SADDLEBROOK DRIVE
City, State, Zip: PORT ST LUCIE , FL, 34986
Owner: !
Design Location: FL, Fort Pierce
Builder Name:
Permit Office: CITY OF PORT ST LUCIE
Permit Number:
Jurisdiction:
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)I
9. Wall Types (3755.8 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=9.0 3465.10 W
b. Frame - Wood, Adjacent
R=13.0 290.67 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (4218.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 4218.00 ft2
6. Conditioned floor area above grade (ft2) 4218
b. N/A
R= ft2
Conditioned floor area below grade (ftZ) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(686.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 180
a. U-Factor: Sgl, U=0.65 686.00-ft2
b. Sup: Attic, Ret: Attic, AH: Garage
6 140
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
42.0 SEER:16.00
i
b. Central Unit
29A SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftZ
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
b. Electric Strip Heat
27.0 COP:1.00
Area Weighted Average Overhang Depth: 4.379 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
8. Floor Types (4218.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 4218.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.163 Total Proposed Modified Loads: 121.23
PASS
Total Baseline Loads: 128.95
I
I hereby certify that the plans and specifications covered by
Review of the plans and
,O -TJiE Sr,'
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
'
with the Florida Energy Code.
mr�,'<.;;:€i ', •�"„ O
PREPA D
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
V
I herebycertify that this building, as e i ned, is in compliance
fY 9. 9 P
lorida Energy Code.
Florida Statutes.
'�?• 5
G'Op
H,E:�R�'
W�witha
AGENT
BUILDING OFFICIAL:
DATE: Z
DATE:
- Compliance requires certi ation by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1
and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FILE C
SPY
1/24/2018 9:51 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 8
FORM R4n5-2n17
PROJECT
Title:
MAHFOOD RESIDENCE
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
4218
Lot #
Owner Name:
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Rotate An gle:
0
Street:
7832 SADDLEBROOK
Permit Office:
CITY OF PORT ST LUCIE
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
Whole House Fan:
No
City, State,
Zip:
PORT ST LUCIE
,
Family Type:
Single-family
FL, 34986
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design
Daily Temp
Design Location
TMY Site
97.5' %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
AHU 1
2464
27831.7
2
AHU 2
1754
1
18221.4
SPACES
Number
Name
Area
Volume
Kitchen
Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
KITCHEN
423
4695.3 Yes
i
0
1
Yes
Yes
Yes
2
MEDIA ROOM
287
4018 No
0
1
Yes
Yes
Yes
3
GYM
474
4313.4 No
0
1
Yes
Yes
Yes
4
CLST
22
200.2 No
0
1
Yes
Yes
Yes
5
BATH 3
66
600.6 No
0
1
Yes
Yes
Yes
6
MEDIA HALL
16
145.6 No
0
1
No
Yes
Yes
7
CLST 3
22
200.2 No
0
1
Yes
Yes
Yes
8
BEDROOM 3
225
3150 No
0
1
1
Yes
Yes
Yes
9
BATH 2
99
900.9 No
0
1
Yes
Yes
Yes
10
BEDROOM2
225
I
3150 No
0
1
1
Yes
Yes
Yes
11
CLST 2
30
273 No
0
1
Yes •
Yes
Yes
12
HALL
36
327.6 No
0
1
No
Yes
Yes
13
LAUNDRY
63
573.3 No
0
1
No
Yes
Yes
14
FAMILY ROOM
476
5283.6 No
0
1
Yes
Yes
Yes
15
DINING ROOM
225
2497.5 No
0
1
Yes
Yes
Yes
16
STUDY
225
2498 No
0
1
Yes
Yes
Yes
17
FOYER
115
1046.5 No
0
1
Yes
Yes
Yes
18
LIVING
301
3341.1 No
0
1
Yes
Yes
Yes
19
WET BAR
72
655.2 No
0
1
No
Yes
Yes
20
HALF BATH
36
327.6 No
0
1
Yes
Yes
Yes
21
M HALL
25
227.5 No
0
1
No
Yes
Yes
1/24/2018 9:51 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 8
FORM R405-2017
SPACES
Number Name Area Volume
Kitchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
22
M WIC 2 52
473.2
No
0
1 No
Yes
Yes
23
M TOILET 24
218.4
No
0
1 No
Yes
Yes
24
MASTER BATH 246 2238.6
No
0
1 Yes
Yes
Yes
25
M WIC 1 54
491.4
No
0
1 Yes
Yes
Yes
26
MASTER BEDROO 379 4206.9
I No
0
1
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter
Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
KITCHEN
8!1 8 ft
0
423 ft2
-_--
1
0
0
2 Slab -On -Grade Edge Insulation
MEDIA ROOM
I
33.2 ft
I
0
287 ft2
__e
1
0
0
3 Slab -On -Grade Edge Insulation
GYM
43.2 ft
0
474 ft2
____
1
0
0
4 Slab -On -Grade Edge Insulation
CLST
2 ft
0
22 ft2
__-_
1
0
0
5 Slab -On -Grade Edge Insulation
BATH 3
I
6 ft
0
66 ft2
____
1
0
0
6 Slab -On -Grade Edge Insulation
MEDIA HALL
11 ft
0
16 ft2
1
0
0
7 Slab -On -Grade Edge Insulation
CLST 3
2 ft
0
22 ft2
____
1
0
0
8 Slab -On -Grade Edge Insulation
BEDROOM 3
23 ft
I
0
225 ft2
1
0
0
9 Slab -On -Grade Edge Insulation
BATH 2
9 ft
0
99 ft2
__e
1
0
0
10SIab-On-Grade Edge Insulation
BEDROOM2
15 ft
0
225 ft2
__�
1
0
0
11Slab-On-Grade Edge Insulation
CLST 2
2 ft
0
30 ft2
1
0
0
12SIab-On-Grade Edge Insulation
HALL
11 ft
0
36 ft2
-__-
1
0
0
13SIab-On-Grade Edge Insulation
LAUNDRY
1 ft
0
63 ft2
____
1
0
0
14SIab-On-Grade Edge Insulation
FAMILY ROOM
16 ft
0
476 ft2
1
0
0
15SIab-On-Grade Edge Insulation
DINING ROOM
13.6 ft
0
225 ft2
____
1
0
0
16SIab-On-Grade Edge Insulation
STUDY
16.6 ft
0
225 ft2
---_
1
0
0
17SIab-On-Grade Edge Insulation
FOYER
17 ft
0
115 ft2
1
0
0
18SIab-On-Grade Edge Insulation
LIVING
13 ft
0
301 ft2
__e
1
0
0
19SIab-On-Grade Edge Insulation
WET BAR
1 ft
0
72 ft2
__--
1
0
0
20SIab-On-Grade Edge Insulation
HALF BATH
6ft
0
36 ft2
-_--
1
0
0
21SIab-On-Grade Edge Insulation
M HALL
1 ft
0
25 ft2
____
1
0
0
22SIab-On-Grade Edge Insulation
M W IC 2
1 ft
0
52 ft2
____
1
0
0
23SIab-On-Grade Edge Insulation
M TOILET
1 ft
0
24 ft2
__e
1
0
0
1/24/2018 9:51 AM EnergyGauge® USA-'FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 8
i=(1RI A RenF_7017
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
24SIab-On-Grade Edge Insulation
MASTER BATH 39.9 ft
0
246 ft2
___
1
0 0
25SIab-On-Grade Edge Insulation
M W IC 1 9 ft
0
54 ft2
1
0 0
26SIab-On-Grade Edge Insulation
MASTER BEDRO 43.3 ft
0
379 ft2
1
0 0
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck Pitch
#
Type Materials Area
Area
Color
Absor. Tested
Tested
Insul. (deg)
1
Hip Barrel tile 47171ft2
I
0 ft2 Medium
0.6
No
0.9
No
20 26.6
ATTIC
IRCC
#
Type
Ventilation Vent Ratio (1 in)
Area
RBS
1
Full attic
Unvented
0
4218 ft2
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented)
KITCHEN
20
Blown
423 ft2
0.1
Wood
2
Under Attic (Unvented)
MEDIA ROOM
20
Blown
287 ft2
0.1
Wood
3
Under Attic (Unvented)
GYM i
20
Blown
474 ft2
0.1
Wood
4
Under Attic (Unvented)
CLST
20
Blown
22 ft2
0.1
Wood
5
Under Attic (Unvented)
BATH 3
20
Blown
66 ft2
0.1
Wood
6
Under Attic (Unvented)
MEDIA HALL
20
Blown
16 ft2
0.1
Wood
7
Under Attic (Unvented)
CLST 3
20
Blown
22 ft2
0.1
Wood
8
Under Attic (Unvented)
BEDROOM 3
I
20
Blown
225 ft2
0.1
Wood
9
Under Attic (Unvented)
BATH 2
20
Blown
99 ft2
0.1
Wood
10
Under Attic (Unvented)
BEDROO,M2
20
Blown
225 ft2
0.1
Wood
11
Under Attic (Unvented)
CLST 2
20
Blown
30 ft2
0.1
Wood
12
Under Attic (Unvented)
HALL
20
Blown
36 ft2
0.1
Wood
13
Under Attic (Unvented)
LAUNDRY
20
Blown
63 ft2
0.1
Wood
14
Under Attic (Unvented)
FAMILY ROOM
20
Blown
476 ft2
0.1
Wood
15
Under Attic (Unvented)
DINING ROOM
20
Blown
225 ft2
0.1
Wood
16
Under Attic (Unvented)
STUDY
20
Blown
225 ft2
0.1
Wood
17
Under Attic (Unvented)
FOYER
20
Blown
115 ft2
0.1
Wood
18
Under Attic (Unvented)
LIVING
20
Blown
301 ft2
0.1
Wood
19
Under Attic (Unvented)
WET BAR
20
Blown
72 ft2
0.1
Wood
20
Under Attic (Unvented)
HALF BATH
20
Blown
36 ft2
0.1
Wood
21
Under Attic (Unvented)
M HALL
20
Blown
25 ft2
0.1
Wood
22
Under Attic (Unvented)
M WIC 2
20
Blown
52ft2
0.1
Wood
23
Under Attic (Unvented)
M TOIL'ET
20
Blown
24 ft2
0.1
Wood
24
Under Attic (Unvented)
MASTER BATH
20
Blown
246 ft2
0.1
Wood
25
Under Attic (Unvented)
M W IC 1
20
Blown
54 ft2
0.1
Wood
26
Under Attic (Unvented)
MASTER BEDRO
20
Blown
379 ft2
0.1
Wood
1/24/2018 9:51 AM EnergyGauge® USA'- FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 8
FORM R405-2017
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
Space
-
Ft
-
1
SW
Exterior
Concrete Block - Int Insul KITCHEN
9
2
0
11
1
22.2 ft2
0
0
0.6
0
2
W
Exterior
Concrete Block - Int Insul KITCHEN 1
9
2
10
11
1
31.4 ft2
0
0
0.6
0
3
NW
Exterior
Concrete Block - Int Insul KITCHEN
9
4
0
11
1
44.3 ft2
0
0
0.6
0
4
W
Exterior
Concrete Block - Int InsuMEDIA ROO
9
3
7
14
0
50.2 ft2
0
0
0.6
0
_ 5
NW
Exterior
I
Concrete Block- Int InsuMEDIA ROO
9
9
0
14
0
126.0 ft2
0
0
0.6
0
6
N
Exterior
I
Concrete Block - Int InsuMEDIA R00
9
3
7
14
0
50.2 ft2
0
0
0.6
0
7
NE
Exterior
I
Concrete Block - Int InsuMEDIA ROO
9
17
0
14
0
238.0 ft2
0
0
0.6
0
8
SW
Exterior
Concrete Block - Int Insul GYM
9
22
0
9
1
199.8 ft2
0
0
0.6
0
9
W
Exterior
Concrete Block - Int Insul GYM
9
3
7
9
1
32.5 ft2
0
0
0.6
0
_ 10
NW
Exterior
Concrete Block - Int Insul GYM
9
14
0
9
1
127.2 ft2
0
0
0.6
0
11
N
Exterior
Concrete Block - Int Insul GYM I
9
3
7
9
1
32.5 ft2
0
0
0.6
0
12
NE
Exterior
Concrete Block - Int Insul CLST
9
2
0
9
1
18.2 ft2
0
0
0.6
0
13
NE
Exterior
Concrete Block - Int Insul BATH 3
9
6
0
9
1
54.5 ft2
0
0
0.6
0
14
NE
Exterior
Concrete Block - Int Insul CLST 3
9
2
0
9
1
18.2 ft2
0
0
0.6
0
15
SE
Exterior
Concrete Block - Int InsuBEDROOM 3
9
4
0
14
0
56.0 ft2
0
0
0.6
0
16
NW
Exterior
Concrete Block - Int InsuBEDROOM 3
9
4
0
14
0
56.0 ft2
0
0
0.6
0
17
NE
Exterior
Concrete Block - Int InsuBEDROOM 3
9
15
0
14
0
210.0 ft2
0
0
0.6
0
_ 18
NE
Exterior
Concrete Block - Int Insul BATH 21
9
9
0
9
1
81.8 ft2
0
0
0.6
0
_ 19
NE
Exterior
Concrete Block - Int InsuBEDROOM2
i
9
15
0
14
0
210.0 ft2
0
0
0.6
0
20
NE
Exterior
Concrete Block- Int Insul CLST 21
9
2
0
9
1
18.2 ft2
0
0
0.6
0
21
SW
Exterior
I
Concrete Block - Int InsLFAMILY ROO
9
16
0
11
1
177.3 ft2
0
0
0.6
0
22
SE
Exterior
Concrete Block - Int InsuDINING ROO
9
10
0
11
1
110.8 ft2
0
0
0.6
0
23
S
Exterior
Concrete Block - Int InsuDINING ROO
9
3
7
11
1
39.7 ft2
0
0
0.6
0
24
E
Exterior
Concrete Block- Int Insul STUDY
9
3
7
11
1
39.7 ft2
0
0
0.6
0
25
SE
Exterior
Concrete Block- Int Insul STUDY
9
13
0
11
1
144.1 ft2
0
0
0.6
0
26
SE
Exterior
Concrete Block- Int Insul FOYER
9
18
0
9
1
163.5 ft2
0
0
0.6
0
27
NW
Exterior
Concrete Block - Int Insul LIVING
9
13
0
11
1
144.1 ft2
0
0
0.6
0
28
NW
Exterior
Concrete Block - Int InsuIHALF BATH
9
6
0
9
1
54.5 ft2
0
0
0.6
0
29
E
Exterior
Concrete Block - Int InsuMASTER 'BA
9
4
6
9
1
40.9 ft2
0
0
0.6
0
30
SE
Exterior
Concrete Block - Int InsuMASTERiBA
9
12
0
9
1
109.0 ft2
0
0
0.6
0
31
S
Exterior
Concrete Block - Int InsuMASTER, BA
9
4
6
9
1
40.9 ft2
0
0
0.6
0
32
SW
Exterior
Concrete Block - Int InsuMASTER BA
9
15
0
9
1
136.3 ft2
0
0
0.6
0
33
NE
Exterior
Concrete Block - Int InsuMASTER BA
9
4
0
9
1
36.3 ft2
0
0
0.6
0
34
SW
Exterior
Concrete Block- Int Insul M W IC,1
9
9
0
9
1
81.8 ft2
0
0
0.6
0
_ 35
SW
Exterior
Concrete Block - Int InsuMASTER BE
9
20
0
11
1
221.7 ft2
0
0
0.6
0
_ 36
W
Exterior
Concrete Block - Int InsuMASTER BE
9
4
3
11
1
47.1 ft2
0
0
0.6
0
37
NW
Exterior
Concrete Block - Int InsuMASTER BE
9
6
0
11
1
66.5 ft2
0
0
0.6
0
38
N
Exterior
Concrete Block - Int InsuMASTER BE
9
12
1
11
1
133.9 ft2
0
0
0.6
0
_39
NE
Garage
Frame -Wood LAUNDRY
13
1
0
9
1
9.1ft2
0
0
0.6
0
_40
SE
Garage
Frame - Wood DINING ROO
13
24
9
1
218.0ft2
0
0
0.600000
0
41
NE
Garage
Frame - Wood DINING ROO
13
7
9
1
63.6 ft2
0
0
0.600000
0
1/24/2018 9:51 AM EnergyGauge® USA; FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 8
FORM R405-2017
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
SW
Insulated
HALF BATH
None
.39
2
6
6 8
16.7 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V #
Omt
ID
Frame
Panes
NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
SW
1
TIM
Low-E Single
Yes
0.65
0.25
N
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
2
W
2
TIM
Low-E Single
Yes
I 0.65
0.25
N
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
3
NW
3
TIM
Low-E Single
Yes
0.65
0.25
N
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
4
W
4
TIM
Low-E Single
Yes
0.65
0.25
N
10.0 ft2
2 ft 0 in
1 ft 4 in
None
None
5
N
6
TIM
Low-E Single
Yes
0.65
0.25
N
10.0 ft2
2 ft 0 in
1 ft 4 in
None
None
6
NE
7
TIM
Low-E Single
Yes
0.65
0.25
N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
7
SW
8
TIM
Low-E Single
Yes
0.65
0.25
N
48.0 ft2
2 ft 0 in
1 ft 4 in
None
None
8
W
9
TIM
Low-E Single
Yes
0.65
0.25
N
10.0 ft2
2 ft 0 in
1 ft 4 in
None
None
9
NW
10
TIM
Low-E Single
Yes
i
0.65
0.25
N
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
10
N
11
TIM
Low-E Single
Yes
0.65
0.25
N
10.0 ft2
2 ft 0. in
1 ft 4 in
None
None
11
NE
13
TIM
Low-E Single
Yes
0.65
0.25
N
9.0 ft2
2 ft 0 in
1 ft 4 in
None
None
12
NE
17
TIM
Low-E Single
Yes
0.65
0.25
N
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
13
NE
17
TIM
Low-E Single
Yes
0.65
0.25
N
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
14
NE
18
TIM
Low-E Single
Yes
0.65
0.25
N
9.0 ft2
2 ft 0 in
1 ft 4 in
None
None
15
NE
19
TIM
Low-E Single
Yes
0.65
0.25
N
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
16
SW
21
TIM
Low-E Single
Yes
0.65
0.25
N
18.0 ft2
2 ft 0 in
1 ft 4 in
None
None
17
SW
21
TIM
Low-E Single
Yes
0.65
0.25
N
40.0 ft2
14 ft 0 in
1 ft 4 in
None
None
18
SE
22
TIM
Low-E Single
Yes
0.65
0.25
N
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
19
SE
22
TIM
Low-E Single
Yes
0.65
0.25
N
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
20
S
23
TIM
Low-E Single
Yes
0.65
0.25
N
6.0 ft2
2 ft 0 in
1 ft 4 in
None
None
21
S
23
TIM
Low-E Single
Yes
0.65
0.25
N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
22
E
24
TIM
Low-E Single
Yes
0.65
0.25
N
6.0 ft2
2 ft 0 in
1 ft 4 in
None
None
23
E
24
TIM
Low-E Single
Yes
0.65
0.25
N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
24
SE
25
TIM
Low-E Single
Yes
0.65
0.25
N
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
25
SE
25
TIM
Low-E Single
Yes
0.65
0.25
N
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
26
SE
26
TIM
Low-E Single
Yes
0.65
0.25
N
6.0 ft2
2 ft 0 in
1 ft 4 in
None
None
27
SE
26
TIM
Low-E Single
Yes
0.65
0.25
N
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
28
SE
26
TIM
Low-E Single
Yes
0.65
0.25
N
48.0 ft2
2 ft 0 in
1 ft 4 in
None
None
29
NW
27
TIM
Low-E Single
Yes
0.65
0.25
N
48.0 ft2
14 ft 0 in
1 ft 4 in
None
None
30
E
29
TIM
Low-E Single
Yes
0.65
0.25
N
6.0 ft2
2 ft 0 in
1 ft 4 in
None
None
31
E
29
TIM
Low-E Single
Yes
0.65
0.25
N
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
32
SE
30
TIM
Low-E Single
Yes
0.65
0.25
N
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
33
SE
30
TIM
Low-E Single
Yes
0.65
0.25
N
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
34
S
31
TIM
Low-E Single
Yes
0.65
0.25
N
6.0 ft2
2 ft 0 in
1 ft 4 in
None
None
35
S
31
TIM
Low-E Single
Yes
0.65
0.25
N
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
36
SW
35
TIM
Low-E Single
Yes
0.65
0.25
N
24.0 ft2
2 ft 0 in
1 ft 4 in
None
None
37
W
36
TIM
Low-E Single
Yes
0.65
0.25
N
10.0 ft2
2 ft 0 in
1 ft 4 in
None
None
38
NW
37
TIM
Low-E Single
Yes
0.65
0.25
N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
1/24/2018 9:51 AM EnergyGauge® USA-' FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 8
Ff7RM R40S-2017
WINDOWS
Orientation shown is the entered, Proposed orientation.
v #
Wall
Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
39
40
N 38 TIM Low-E Single
N 38 TIM Low-E Single
Yes
Yes
0.65 0.25 N 10.0 ft2 2 ft0 in 1 ft4 in None
0.65 0.25 N 48.0 ft? 14 ft 0 in 1 ft 4 in None
None
None
GARAGE
i
#
Floor Area Ceiling Area
,Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
1104 ft2 1104 ft2
I 31 ft 9 ft 13
INFILTRATION
# Scope
Method
SLA
I
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000486
5I372.9 294.97 554.73 .3545 7
HEATING SYSTEM
i
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
2
Electric Strip Heat/
Electric Strip Heat/
None
None
COP:1 27 kBtu/hr 1
COP:1 27 kBtu/hr 2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit/
Central Unit/
Split
Split
SEER: 16 42 kBtu/hr 1260 cfm 0.8 1
SEER: 16 29.4 kBtu/hr 882 cfm 0.8 2
sys#1
sys#2
HOT WATER SYSTEM
System Type SubType
Location
I EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.98 40 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
I Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
#
-- Supply --
Location R-Value Area
-- Return -- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT ON RLF
HVAC #
Heat Cool
1
2
Attic 6 180 ft2
Attic 6 140 ft2
Attic
Attic
18 ft2 Default Leakage Garage (Default) c(Default) c
14 ft2 Default Leakage Garage (Default) c(Default) c
1 1
2 2
1/24/2018 9:51 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 7 of 8
FORM R405-2017
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Cooling Jan
Heat in Jan
Feb
Feb
Mar
Mar
Apr
A r
i
May
May
Jun
Jun
Jul
Jul
AugSep
Auge
Oct
Oct
Nov
Nov
Dec
Dec
Venting Jan
Feb
Mar
Apr
May
Jun
Jul
Aug
Sep
Oct
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
1 4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
178
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (W EH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (W D)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
1/24/2018 9:51 AM EnergyGauge® USA FlaRes2017 Section R405.4.1 Compliant Software Page 8 of 8
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: MAHFOOD RESIDENCE Builder Name:
Street: 7832 SADDLEBROOK DRIVE Permit Office: CITY OF PORT ST LUCIE
City, State, Zip: PORT ST LUCIE , FL, 34986 Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
I
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be 'sealed.
Ceiling/attic
I
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation in the barrier be
The insulation in any dropped ceiling/soffit
and any gaps air shall sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls shall
The junction of the top plate and the top of exterior walls shall be sealed.
be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
I
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
i
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed:
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wirin .
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. in addition, inspection or iog walls shall be in accordance with the provisions of ICC-400.
1/24/2018 9:52 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the EnergyPerformance Index, the more efficient the home.
7832 SADDLEBROOK DRIVE, PORT ST LUCIE, FL, 34986
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows-
Description
a. U-Factor:
Sgl, U=0.65
SHGC:
SHGC=0.25
b. U-Factor:
N/A
SHGC:
c. U-Factor:
N/A
SHGC:
d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
New (From Plans)
9. Wall Types
Insulation
Area
Single-family I
a. Concrete Block - Int Insul, Exterior
R=9.0
3465.10 ft2
b. Framer Wood, Adjacent
R=13.0
290.67 ft2
1
c. N/A
R=
ft2
3
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
No
a. Roof Deck (Unvented)
R=20.0
4218.00 ft2
4218
b. N/A
R=
ft2
c. N/A
R=
ft2
Area
11. Ducts
R ft2
686.00 ft2
a. Sup: Attic, Ret: Attic, AH: Garage
6 180
b. Sup: Attic, Ret: Attic, AH: Garage
6 140
ft2 l
8. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
b. N/A R=
c. N/A R=
12. Cooling systems
kBtu/hr Efficiency
ft2l
a. Central Unit
42.0 SEER:16.00
I
b. Central Unit
29.4 SEER:16.00
ft2
13. Heating systems
kBtu/hr Efficiency
4.379 ft.
a. Electric Strip Heat
27.0 COP:1.00
b. Electric Strip Heat
27.0 COP:1.00
0.250 I
Area
14. Hot water systems
4218.00 ft l
a. Electric
Cap: 4 EF: 0.98
ft21
ft2
b. Conservation features
None
15. Credits
None
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above ener y saving features which will be installed (or exceeded)
in this home before final inspection. therwise, a new EPL Display Card will be completed
based on installed Code compliant f tures.
Builder Signature: Date:
Address of New Home: ��, �� Sa d p 1)1'�, City/FL Zip: Ct �
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/24/2018 9:52 AM EnergyGauge® USA-!FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
Pro ect Summa Job:
wrightsoft® , Date: JANUARY24, 2018
AHU 1 By:
QUICK CALCS, INC.
I
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS a,\OL.COM
For: MAHFOOD RESIDENCE
7832 SAD DLEBROOK DRIVE, PORT ST LUCIE, FL 34986
Notes:
Weather. Fort Pierce, FL, US
Winter Design Conditions
I
Summer Design Conditions
Outside db 42
OF I
Outside db
90
OF
Inside db 70
OF
Inside db
75
OF
Design TD 28
OF
Design TD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
gr/lb
Heating Summary
Sensible Cooling Equipment
Load Sizing
Structure 20735
Btuh
Structure
21964
Btuh
Ducts 7459
Btuh
Ducts
9269
Btuh
Central vent (0 cfm) 0
Btuh
Central vent (0 cfm)
0
Btuh
Humidification 0
Btuh
Blower
0
Btuh
Piping 0
Btuh
Equipment load 28194
Btuh
Use manufacturers data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
29672
Btuh
Method Simplified
Latent Cooling Equipment
Load Sizing
Construction quality
Average
Fireplaces
0
Structure
4341
Btuh
Ducts
2965
Btuh
Heating
Cooling
Central vent (0 cfm)
0
Btuh
Area (ft2) 2464
2464
Equipment latent load
7306
Btuh
Volume (W) 27832
27832
Air changes/hour 0.25
0! 14
Equipment total load
36978
Btuh
Equiv. AVF (cfm) 118
163
Req. total capacity at 0.70 SH R
3.5
ton
Heating Equipment Summary
Cooling Equipment Summary
Make
Make Carrier
Trade
Trade CARRIER AIR CONDITIONING
Model
Cond CA16NA0420000A
AHRI ref
Coil FX4DNF049
AH RI ref 7894072
Efficiency 100 EFF
Efficiency 13.0 EER, 16
SEER
Heating input 8.1
kW
Sensible cooling
29400
Btuh
Heating output 27695
Btuh
Latent cooling
12600
Btuh
Temperature rise. 18
OF
Total cooling
42000
Btuh
Actual air flow 1400
cfm
Actual air flow
1400
cfm
Air flow factor 0.050
cfm/Btuh
Air flow factor
0.045
cfm/Btuh
Static pressure 1.00
in H2O
Static pressure
1.00
in H2O
Space thermostat
Load sensible heat ratio
0.81
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
� ,+ wrightsoft
2018-Jan-24 09:49:18
-- RightSuite® Universal 2017 17.0!08 RSUD8101
�C` E:\Documnets\Wrightsoft WACIMAHFOOD RESIDENCE.rup Calc = MJ8 Front Door faces: SE
Page 1
Pro ect Summa Job:
-�+ wrightsoft® AH+U 2 � Byte: JANUARY 24, 2018
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax
Email: QUICKCALCS@AOL.COM
For. MAHFOOD RESIDENCE
7832 SADDLEBROOK DRIVE, PORTST LUCIE, FL 34986
i
i
Notes:
Design Information
i
Weather Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db
42
OF
Outside db
90
OF
Inside db
70
OF I
Inside db
75
OF
Design TD
28
OF I
Design TD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
gr/lb
Heating
Summary
Sensible Cooling Equipment Load Sizing
Structure
20279
Btuh
Structure
15594
Btuh
Ducts
4608
Btuh
Ducts
6492
Btuh
Central vent (0 cfm)
0
Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0
Btuti
Blower
0
Btuh
Piping
0
Btuh
Equipment load
24887
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
20982
Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
3168
Btuh
Ducts
1744
Btuh
Heating
Coolin�gg
Central vent (0 cfm)
0
Btuh
Area (ft2)
1754
1754
Equipment latent load
4912
Btuh
Volume (ft3)
18221
18221
Air changesthour
0.32
0.17
Equipment total load
25894
Btuh
Equiv. AVF (cfm)
97
52
Req. total capacity at 0.70 SHR
2.5
ton
Heating Equipment Summary , Cooling Equipment Summary
Make
Make Carrier
Trade
Trade CARRIER AIR CONDITIONING
Model
Cond CA16NW0300000A
AHRI ref
Coil FX4DNF037L
AHRI ref 7692728
Efficiency
100 EFF
Efficiency 13.5 EER,
16 SEER
Heating input
7.2
kW
Sensible cooling
20580
Btuh
Heating output
24469
Btuh
Latent cooling
8820
Btuh
Temperature rise
23
°F
Total cooling
29400
Btuh
Actual air flow
980
cfm
Actual air flow
980
cfm
Air flow factor
0.039
cfm/Btuh
Air flow factor
0.044
cfm/Btuh
Static pressure
1.00
in H2O
Static pressure
1.00
in H2O
Space thermostat
Load sensible heat ratio
0.82
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
l- wrightsoft- 2018 Jan-24 09:49:18
.,:— RightSulteO Universal 2017 17.0.08 RSU08101 Page 2
ACC�* EADocumnetslWrightsolt WACIMAHFOOD RESIDENCE.rup Calc = MJ8 Front Door faces: SE
Duct System Summary Job:
- wrightsoft® y Date: JANUARY 24, 2018
AHU 2 By:
QUICK CALLS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fare 772-466-6796 Email: QUICKCALCS AOL.COM
For: MAHFOOD RESIDENCE
7832 SADDLEBROOK DRIVE, PORT ST LUCIE, FL 34986
Extemal static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
' H tin Coolin
ea g
1.00 in H2O
0 in H2O
1.00 in H2O
0.500 / 0.500 in H2O
1.000 in/100ft
980 cfm
i
9
1.00 in H2O
0 in H2O
1.00 in H2O
0.500 / 0.500 in H2O
1.000 in/100ft
980 cfm
209 ft
Supply Branch Detail Table
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
DINING ROOM
c 4062
140
180
1.000
8.0
Ox 0
VIFx
39.9
115.0
st2
HALF BATH
h 792
31
19
1.000
5.0
Ox 0
VIFx
67.6
135.0
st5
LIVING
c 3863
134
171,
1.000
8.0
Ox0
VIFx
34.6
115.0
st2
•TOILET
c 70
1
3
1.000
4.0
OxO
VIFx
62.3
135.0
st5
• WIC 1
h 910
36
15,
1.000
4.0
Ox0
VIFx
62.3
135.0
st5
• WIC 2
c 184
3
8i
1.000
4.0
Ox0
VIFx
55.2
135.0
Sty
MASTER BATH
h 5127
202
141 1
1.000
7.0
Ox 0
VIFx
68.9
135.0
st5
MASTER BEDROOM
h 3526
139
134�
1.000
7.0
OxO
VIFx
73.9
135.0
st5
MASTER BEDROOM -A
h 3526
139
134-
1.000
7.0
Ox 0
VIFx
62.1
135.0
st5
STUDY
c 3679
152
163;
1.000
8.0
Ox 0
VIFx
42.3
115.0
st2
WET BAR
c 227
3
10
1.000
4.0
Ox0
VIFx
56.9
135.0
sty
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FR
(fpm)
(in)
(in)
Material
Trunk
st2
Peak AVF
980
980
1.000
702
16.0
0 x 0
VinlFlx
st5
Peak AVF
554
465
1.000
705
12.0
0 x 0
VinlFlx
st2
wrightsoft' Rlght.SuiteO Universal 2017 17.0.08 RSU08101 2018-Jan-24 09:49:22
Page 3
EADocumnetslWrightsoft HVACIMAHFOOD RESIDENCE.rup Calc = MJ8 Front Door faces: SE
Name
Grill
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb2
Ox 0
980
980
0
. 0
0
0
Ox 0
VIFx
wri htsoft° 2018-Jan-24 09:49:22
JaAlt 9 Right -Suite® Universal 2017 17.0.08 RSU08101 Page 4
k EADocumnetslWrightsoft WACIMAHFOOD RESIDENCE.rup I Calc = MJ8 Front Door faces: SE