HomeMy WebLinkAboutIMPUT DATA REPORTProject Name: Coastal Floors
Project Title: Coastal Floors
Address: 8532 South US Highway 1
State: FL
Zip: 34952
Owner: Coastal Floors
EnergyGauge Summit® v5.10
INPUT DATA REPORT
Proiect Information
Orientation: SouthWest
Building Type: Retail
Building Classification: New Finished building
No.of Stories: 1
GrossArea: 8348 SF
Zones—_
No Acronym Description Type Area Multiplier
t ' 1
Total Area
1 Show Room Show Room CONDITIONED 4045.5 e0%% P.\ C ESN R%+4 0' .5
2 Offices Offices CONDITIONED 645.8 645. e •
jNjo3WarehouseWarehouseUNCONDITIONED3656.3
63 7
e ° 365fr.:;:
3 ST E OF a.
Z/`
O `
O°\env RIN
Ai o0ov 2/
8/2016 EnergyGauge Summit® v5.10.• 0 t; 1
a
Spaces
No Acronym Description Type Depth Width Height Multi Total Area Total Volume
ftl IN IN plier fsll fell
In Zone: Show Room
16.00 1 4045.5 64728.01ShowroomShowroomSalesArea43.50 93.00
In Zone: Offices
El1Office2Office2Office -Enclosed 16.50 11.00 9.00 1 181.5 1633.5
2 Office 1 Office 1 Office - Enclosed 16.50 11.00 9.00 1 181.5 1633.5 El
3 Men's Room Men's Room Toilet and Washroom 7.50 6.50 9.00 1 48.8 438.8
4 Women's Room Women's Room Toilet and Washroom 7.50 6.50 9.00 1 48.8 438.8 El
5 Computer ClosetComputer Closet Electrical Mechanical 9.00 13.00 9.00 1 117.0 1053.0
Equipment Room - General
6 Janitors Closet Janitors Closet Storage & Warehouse - 9.10 7.50 9.00 1 68.3 614.3
Bulky Active Storage
In Zone: Warehouse
1 Stone Storage Stone Storage Storage & Warehouse - 29.50 60.00' 14.00 1 1770.0 24780.0
Bulky Active Storage
2 Main Storage Main Storage Storage & Warehouse - 30.50 60.00 14.00 1 1830.0 25620.0
Bulky Active Storage
3 Shop Bathr000mShop Bathroom Toilet and Washroom 7.50 7.50. 9.00 1 56.3 506.3
Lighting
No Type Category No. of Watts per Power Control Type No.of
Luminaires Luminaire WI Ctrl pts
In Zone: Show Room
In Space: Showroom
1 Compact Fluorescent General Lighting 14 64 896 Manual On/Off 2
In Zone: Offices
In Space: Office 2
1 Compact Fluorescent General Lighting 4 32 128 Manual On/Off 1
2/8/2016 EnergyGauge Summit® v5.10 2
In Space: Office 1
1 Compact Fluorescent General Lighting 4 32 128 Manual On/Off 1
In Space: Men's Room
1 Compact Fluorescent General Lighting 1 40 40 Manual On/Off 1
In Space: Women's Room
1 Compact Fluorescent General Lighting 1 40 40 Manual On/Off 1
In Space: Computer Closet
1 Compact Fluorescent General Lighting 2 64 128 Manual On/Off I
In Space: Janitors Closet
1 Compact Fluorescent General Lighting 1 40 40 Manual On/Off 1
In Zone: Warehouse
In Space: Stone Storage
1 Compact Fluorescent General Lighting 6 64 384 Manual On/Off 2
In Space: Main Storage
1 Compact Fluorescent General Lighting 6 64 384 Manual On/Off 2
In Space: Shop Bathr000m
1 Compact Fluorescent General Lighting 1 40 40 Manual On/Off 1
Walls
No Description Type Width H (Effec) Multi Area Direction Conductance Heat Dens. R-Value
ft] ft] plier sf] Btu/hr. A. F] Capacity lb/cf] [h.sf.FBtu]
Btu/sf.F]
In Zone: Show Room
1 North West Wall 5/8" stucco 93.00 16.00 1 1488.0 NorthWes 0.1162 5.864 31..19 8.6
8"CMU/1-1/2"ISO t
BTWN24"oc/.5"
Gyp
2 South West Wall 5/8" stucco 43.50 16.00 1 696.0 SouthWes 0.1162 5.864 31.19 8.6
8"CMU/1-1/2"ISO t
BTWN24"oc/.5"
Gyp
3 South East Wall 5/8" stucco -50.50 16.00 1 808.0 SouthEast 0.1162 5.864 31.19 8.6
8"CMU/1-1/2"ISO
BTWN24"ocLP
Gyp
2/8/2016 EnergyGauge Summit® v5.10
4 North East Wall Metal 60.00 16.00 1 960.0 NorthEast 0.0743 1.175 17.22 13.5
siding/2x4@24"+Rl
3 Batt/5/8"Gyp
In Zone: Offices
8.61SouthWestWall5/8" stucco 16.50 9.00 1 148.5 SouthWes 0.1162 5.864 31.19
8"CMU/1-1/2"ISO t
BTWN24"oc/.5"
Gyp
2 South East Wall 5/8" stucco 35.00 9.00 1 315.0 SouthEast 0.1162 5.864 31.19 8.6
8"CMU/1-1/2"ISO
BTWN24"oc/.5"
Gyp
3 North East Wall Metal 16.50 16.00 1 264.0 NorthEast 0.0743 1.175 17.22 13.5
siding/2x4@24"+Rl
3 Batt/5/8"Gyp
In Zone: Warehouse
1 South East Wall 5/8" stucco 60.00 14.00 1 840.0 SouthEast 0.1162 5.864 31.19 8.6
8"CMU/1-1/2"ISO
BTWN24"oe/.5"
Gyp
2 North West. Wall 5/8" stucco 60.00 14.00* 1 840.0 NorthWes 0.1162 5.864 31.19 8.6
8"CMU/1-1/2"ISO t
BTWN24"oc/.5"
Gyp
3 North East Wall 5/8" stucco 60.00 14.00 1 840.0 NorthEast 0.1162 5.864 31.19 8.6
8"CMU/1-1/2"ISO
BTWN24"oc/.5"
Gyp--
Windows
No Description Type Shaded U SHGC Vis.Tra W H(Effec) Multi Total Area
Btu/hr sf F] ft] ft] plier sf]
In Zone: Show Room
In Wall: North West Wall
1 Windows User Defined No 0.9000 0.50 0.40 6.00 5.20 5 156.0
In Wall: South East Wall
1 Windows User Defined No 0.9000 0.50 0.40 6.00 5.20 5 156.0
In Wall: South West Wall
2/8/2016 EnergyGauge Summit® v5.10
I Windows User Defined No 0'.9000 0.50 0.40 6.00 7.50 2 90.0
2 SW Windows User Defined Yes 0.9000 0.50, 0.40 10.70 8.10 2 173.3
3 Front Door User Defined Yes 0.9000 0.50 0.40 6.00 8.00 1 48.0
Doors
No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value
ft] IN plier sf] [Btu/hr. sf. F] lb/cf] Btu/sf. F] h.sf.FBtu]
In Zone: Show Room
In Wall: North West Wall
1 Door Solid core flush No 3.00 7.00 1 21.0 0.3504 0.00 0.00 2.85
2.25)
In Zone: Warehouse
In Wall: North East Wall
1 Overhead Doors Solid core flush No 12.00 10.00 2 120.0 0.3504 0.00 0.00 2.85
2.25)
2 Rear Doors Solid core flush No 3.00 7.00 2 21.0 0.3504 0.00 0.00 2.85
2.25)
Roofs.
No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value
IN IN plier sf] deg] [Btu/hr. SE F] Btu/sf. F] [lb/cf] h.sf.FBtu]
In Zone: Show Room
1 Showroom Roof Mtl Bldg Roof/R-10 93-.00- 43.50_ 1 4045.5 0.00 0.0967 0.87 9.57 10.3
ISO
In Zone: Offices
1 Office Roof Mtl Bldg Roof/R-19 35.00 16.50 1 577.5 0.00 0.0492 1.34 9.49 20.3
Batt
In Zone: Warehouse
I Warehouse Roof Mtl Bldg Roof/R-10 60.00 60.00 1 3600.0 0.00 0.0967 0.87 9.57 10.3
ISO
2/8/2016 EnergyGauge Summit® v5.10
Skylights
No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area
Btu/hr sf.F] ft] ft] Sf] [Sf]
In Zone:
In Roof:
Floors
No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value
ft] ft] plier sf] [Btu/hr. sf. F] Btu/sf. F] lb/cf] h.sf.FBtu]
In Zone: Show Room
1 Showroom Floor 1 ft. soil, concrete 93.00 43.50 1 40453 0.2681 34.00 113.33 3.73
floor, carpet and
rubber pad
In Zone: Offices
1 Office Floor 1 ft. soil, concrete 35.00 16.50 1 577.5 0.2681 34.00 113.33 3.73
floor, carpet and
rubber pad
In Zone: Warehouse
1___ _Warehouse Floor 1 ft. soil, concrete 60.00 60.00 1 3600.0 0.2681 34.00 113.33 3.73
floor, carpet and
rubber pad ----
Systems - -- --
AHU-1,2 AHU-1,2 Constant Volume Air Cooled Split No. Of Units 2
System < 65000 Btu/hr
Component Category Capacity Efficiency IPLV
1 Cooling System 58500.00 13.00 13.00
2 Heating System 34121.00 1.00
3 Air Handling System -Supply 1950.00 0.35
2/8/2016 EnergyGauge Summit® v5.10 6
a
4 Air Handling System - Return
5 Air Distribution System (Sup)
6 Air Distribution System (Ret)
1950.00 0.35
6.00
6.00
AHU-3 AHU-3 Constant Volume Air Cooled Split
System < 65000 Btu/hr
No. Of Units 1
Component Category Capacity Efficiency IPLV
1 Cooling System
2 Heating System
3 Air Handling System -Supply
4 Air Handling System - Return
5 Air Distribution System (Sup)
6 Air Distribution System (Ret)
18800.00 16.00 16.00
17061.00 1.00
627.00 0.35
627.00 0.35
6.00
6.00
Plant
Equipment Category Size Inst.No Eff. IPLV
Water Heaters.
W=Heater_Description Capacity Cap.Unit UP Rt. Efficiency Loss
1 Electric water heater 40 -[Gal] - _ [kW] 0.9500 [EfJ Btu/h]
Ext-Lighting ,
Description Category No. of Watts per Area/Len/No. of units Control Type Wattage
Luminaires Luminaire [sf/ft/No] [W]
1 Ext Light 1 Uncovered Parking Areas -- 10 32 0.00 Photo Sensor control 320.00
Parking lots and Drives
2/8/2016 EnergyGauge Summit® v5.10 7
J
Piping
No Type
Operating Insulation Nomonal pipe Insulation Is Runout?
Temperature Conductivity Diameter Thickness
F] [ Btu-in/h.sf.F] [in] [in]
Fenestration Used
Name Glass Type No. of
Glass
SHGC VLT
Panes
Conductance
Btu/h.sf.F]
ASHULDb1TntM User Defined 2 0.9000 0.5000 0.4000
tl-Oth frm
Materials Used
Only R-Value RValue Thickness Conductivity Density SpecificHeat
Mat_ No Acronym Description
Used h.sf.FBtu] ft] Btu/h.ft.F] lb/cf] Btu/1b.F]
187 Mad187 GYP OR PLAS - -- - _ _ No 0.4533 0.0417 0.0920 50.00 0.2000 Li
BOARD, l /2IN
178 Mat1178 CARPET W/RUBBER PAD Yes L2300
265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000
48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000
268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000
42 Mat142 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000
block
269 Mat1269 75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000
12 Matl12 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000
23 Matl23 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000
4 Matl4 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000
2/8/2016 EnergyGauge Summit® v5.10 8
271 Mat1271 2x4@24" oc + RI Batt No 10.4179 0.2917 0.0280 7.11 0.2000 L] I94Mat194BUILT UP ROOFING, 3/81N No 0.3366 0.0313 0.0930 70.00 0.3500
Constructs Used
Simple Massless Conductance Heat Capacity Density RValue
No Name Construct Construct Btu/h.sf.F] Btu/sf.F] Ib/ct] h.sf.FBtu]
1011 5/8" stucco /8"CMU/1-1/2"ISO No' No. 0.12 5.86 31.19 8.6
BTWN24"oc/.5" Gyp
Layer Material Material Thickness Framing
No. ft] Factor
1 268 0.625" stucco 0.0521 0.000
2 42 8 in. Lightweight concrete block 0.6670 0.000
3 269 75" ISO BTWN24" oc 0.1680 0.000
4 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000
Simple Massless Conductance Heat Capacity Density RValue
No Name
Construct Construct Btu/h.sf.F] Btu/sf.F] lb/cf] h.sf.FBtu]
1046 Mtl Bldg Roof/R-10 ISO No No 0.10 0.87 9.57 10.3
Layer Material Material Thickness Framing
No. ft] Factor
1 94'—~ BUILTUP ROOFING, 3/81N 0.0313 0.000
2 12 3 in. Insulation ---------- 0.2500 0.000
2/8/2016
I
i
EnergyGauge Summit® v5.10, 9
Simple Massless Conductance Heat Capacity Density RValue
No Name
Construct Construct Btu/h.sf.F] Btu/sf.F] lb/cf] h.sf.F/Btu]
1055 Metal siding/2x4@24"+R13 Batt/5/8"Gyp No No 0.07 1.17 17.22 13.5
Layer Material Material Thickness Framing
No. ft] Factor
1 4 Steel siding 0.0050 0.000
2 271 2x4@24" oc + R1I Batt 0.3640 0.000
3 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000
Simple Massless Conductance Heat Capacity Density RValue
No Name
Construct Construct Btu/h.sf.F] Btu/sf.F] lb/cf] h.sf.FBtu]
1056 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3
Layer Material Material Thickness Framing
No. ft] Factor
1 94 BUILT-UP ROOFING, 3/81N 0.0313 0.000
2 23 6 in. Insulation 0.5000 0.000
Simple Massless Conductance Heat Capacity Density RValue
No Name
Construct Construct Btu/h.sf.F] Btu/sf.F] lb/cf] h.sf.FBtu]
1057 1ft. soil, concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7
Layer Material Material - Thickness Framing
No. ft]- - _ Factor
1 265 Soil, 1 ft 1.0000 0.000 —
2 48 6 in. Heavyweight concrete 0.5000 0.000
3 178 CARPET W/RUBBER PAD 0.000
2/8/2016 EnergyGauge Summit® v5.10 10
w
Simple Massless Conductance Heat Capacity Density RValue
No Name
Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu]
1058 Solid core flush (2.25) No Yes 0.35 2.9
Layer Material Material Thickness Framing
No. IN Factor
1 279 Solid core flush (2.25") 0.000
2/8/2016 EnergyGauge Summit® v5.10 11
i