Ingenuity Engineers, Inc., is in receipt of permit comments for the above named project. We
have reviewed the comments v ith respect to our disciplines and have the following responses:
MECHANICAL: I
Comment: Please list approved material for condensation line.
Response: Will comply, s e revised sheet M-0.1.
Comment: Note 8, Page M2.0 requires "Exposed spiral single wall snap lock paint grip
ductwork". Pla s indicated spiral ductwork, not snap lock.
Response: Note 8 revise , see revised sheet M2.0.
Comment: Please submi hanger detail for exposed ductwork.
Response: Will comply, see revised sheet M-4.2.
Comment: FCU #2 is rat, d for 1600 CFM. Total on plans adds up to 1800 CFM.
Response: Schedule remised to match floor plan cfm. See revised sheet M3.1.
PLUMBING:
Fv
ingenuity engineers, inc.
4798 new broad street. suite 300. oriando. florida 32814 . phone: 407. 398.6007 fax: 407.398.6003 C.A. #26308
Becker Household November 18, 2015
115037.00 Page 2 of 2
Comment: This is an occupan y classification change from residential to assembly and
business. Per Secti n 1012.8 of the Florida Existing Building Code, this building
now has to meet the requirements of the 2014 Florida Plumbing Code.
Response: Will comply, see revised floor plan sheets.
Comment: This is an occupancy classification change from residential to assembly and
business. Per Sec ion 1010 of the 2014 Florida Existing Building Code, this
building now has to meet the requirements of the 2014 Florida Accessibility ode. ,
Response: Will comply, see r vised floor plan sheets.
Comment: Per Section 403. of the 2014 Florida Plumbing Code, this building is now
required to have s parate sex restrooms.
Response: Will comply, see evised floor plan sheets.
Comment: Per Table 403.1 o the 2014 Florida Plumbing Code and Section 211 of the 2014
Florida Accessibi ity, this building is now required to have a Hi-Lo drinking
fountain.
Response: Will comply, see revised floor plan sheets.
Comment: Per Table 403.1 f the 2014 Florida Plumbing Code, this building is ow required
to have a service sink.
Response: Will comply, see revised floor plan sheets.
If there are any additional questions or comments, please feel free to contact us.
Sincerely,
4-v- -
Brian S. Hessinger, PE, LEED AP
Chief Operating Officer
RECEIVED
NOV 2 3 2015
ENVIRONMENTAL
RESOURCES
ingenuity engineers, inc.
4798 new broad street. suite 300. orlando. florida 32814 • phone: 407.398.6007 fax: 407.398.6003 C.A. #26308
aB
Don Bergman
Architecture,
LLC.
Lic. # AA 26002432
23 lS •.
MEMORAND
TO St. Lucie C 'unty SUBJECT Permit #1108-0127
Building Dopt St. Lucie County Becker House
FROM Don Ber
DATE 11.23.15
We are in receipt of Bu
responses:
1. Please show in
load requirem(
II. - R:
2.
3.
4.
5.
P.O. Box 13537
Fort Pierce, FL 34979-3537
4362 Gator Trace Lane
Fort Pierce, FL 34982
T:772.466.5832
Q 772.708.0164
Please not lev
R:
Please show c
R:
Please show c
R:
Please show/
Snack Bar? Ai
R:
A sleeping are
R:
NO. 15-012
Dept. comments and have reviewed them and offer the following
)esign Criteria block separate occupancy areas with associated occupancy
Its.
See revised Dimensional Control Floor Plan, Sheet A-1.0
alteration/change of occupancy in Design Criteria
See revised Dimensional Control Floor Plan, Sheet A-1.0, and revised
Garage Floor Plan, Sheet A-1.1.
iphance with FBC Accessibility for all door widths, new and existing.
See revised Dimensional Control Floor Plan and revised Life Safety
Floor Plan, sheets A-1.0 and LS-1.0 for minimum clear floor areas at new
and existing doors.
iphance with FBC Accessibility for all door hardware, new and existing.
New and existing door harware shall comply with applicable portions of
FBC Accessibility Section 404.
scribe use of the Kitchen. Is this a commercial kitchen with any seating?
cooking?
See revised Dimensional Control Floor Plan, Sheet A-1.0. Room title
changed to "Staff Breakroom" to reflect its proposed use. No cooking will
occur in this space.
a cannot open into a Garage, per FBC R302.5.1.
See revised Garage Floor Plan, Sheet A-1.1.