HomeMy WebLinkAboutROOF TRUSSESLumber design values are in accordance with ANSI/TPI 1-2007 section 6.3
A-1 ROOF These truss desi i ns rely on lumber values established by others.
TRUSSES
A FLORIDA CORPORATION
RE: Job 72005 �� ���L9� �� A-1 Roof Trusses
4451 St Lucie Blvd
Fort Pierce, FL 34946
Site Information:
Customer Info: COASTAL CONSTRUCTION AND DESIGN, INC. Project Name: LANDERS
Lot/Block: Model: LANDERS
Address: 4582 OCEAN DR., JENSEN BEACH, FL Subdivision:
City: County' St Lucie State: FL
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: James Bushouse License #: 20311
Address: 1176 SW 4th Court
City: Boca Raton, FL 33432
General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1
Wind Code: ASCE 7-10 Wind Speed: 180
Roof Load: 55.0 psf Floor Load: 0.0 psf
This package includes 91 individual, dated Truss Design Drawings and 16 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design (Engineer and this index sheet
conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules.
No.
Seal #
Truss Name
Date
No.
Seal #
Truss Name
Date
No.
Seal #
Truss Name
Date
1
A0117193
A01AG
5/3/18
13
A0117205
IA07A
5/3118
25
A0117217
A13A
5/3/18
2
A0117194
A01 G
5/3/18
14
A0117206
I A08
5/3/18
26
A0117218
A14
5l3/18
3
A0117195
A02
5/3/18
15
A0117207
A08A
5/3/18
27
A0117219
A14A
5/3118
4
A0117196
A02A
5/3118
16
A0117208
A09
513/18
28
A0117220
A15
5l3/18
5
A0117197
A03
5/3/18
17
A0117209
A09A
513118
29
A0117221
A16
5/3/18
6
A0117198
A03A
5/3/18
18
A0117210
I A10
513118
30
A0117222
A17
5/3/18
7
A0117199
A04
5/3/18
19
A0117211
I A10A
5/3/18
31
A0117223
A18
5/3/18
8
A0117200
A05
5/3/18
20
A0117212
I Al l
5/3/18
32
A0117224
Al9G
5/3/18
9
A0117201
A05A
5/3/18
21
A0117213
A11A
5l3/18
33
A0117225
B01G
5/3/18
10
A0117202
A06
5/3/18
22
A0117214
I Al2
5/3/18
34
A0117226
B02
5/3/18
11
A0117203
1 A06A
5/3/18
1 23
A0117215
Al2A
5l3/18
35
A0117227
B03
5/3/18
12
A0117204
1 A07
5/3/18
24
A0117216
I A13
5/3/18
36
1 A0117228
B04G
5/3/18
The truss drawings) referenced have been prepared by M7ek Industries, Inc. under my direct supervision based on the parameters provided byA-1 Roof Trusses,
Ltd.
Truss Design Engineer's Name: Anthony Tombo III
My license renewal date for the state of Florida is February 28,2019.
NOTE.The seal on these drawings indicate acceptance of professional
engineering responsibility solely for the truss components shown.
I
The suitability and use of components for any particular building is the responsibility of the
building designer, per ANSI/TPl-1 Sec. 2.
The Truss Design Draw!ng(s)(TDD[s)) referenced have been prepared basedion the
construction documents (also referred to at times as 'Structural Engineering Documents)
provided by the Building Designer indicating the nature and character of the work.
The design criteria therein have been transferred to Anthony Tombo III PE by [Al Roof
Trusses or specific location]. These TDDs (also referred to at times as 'Structural Delegated
Engineering Documents) are specialty structural component designs and may be part of the
project's deferred or phased submittals. As a Truss Design Engineer (i.e., Specialty
Engineer), the seal here and on the TDD represents an acceptance of professional pntl�gny T.
engineering responsibility for the design of the single Truss depicted on the TDD only-. e
Building Designer is responsible for and shall coordinate and review the TDDs for
compatibility with their written engineering requirements. Please review all TDDs and all
related notes.
3BBCA22100 0060 004C1287DF
(Page 1 of 2
Lumber design values are in accordance with ANSI(TPI 1-2007 section 6.3
A-1 ROOF hese truss designs rely on lumber values established by others.
TRUSSES 9
A FLORIDA CORPORATION
RE: Job 72005
No.
Seal #
Truss Name
Date
No.
Seal #
Truss Name
-Date
37
A0117229
C01 G
5/3/18
75
A0117267
J713
5/3/18
38
A0117230
CO2
5/3118
76
A0117268
MHV10
5/3/18
39
A0117232
CJ1
5/3/18
77
A0117269
MHV12
5/3/18
40
A0117231
CJ1-3
5/3/18
78
A0117270
MHV14
5/3/18
41
A0117233
CJ1C
5/3/18
79
A0117271
MHV16
5/3/18
42
A0117235
CJ3
5/3/18
80
A0117272
MHV2
5/3/18
43
A0117234
CJ3-3
5/3/18
81
A0117273
MHV8
5/3/18
44
A0117236
CJ3A
5/3/18
82
A0117274
MV10
5/3/18
45
A0117237
CJ3C
513/18
83
A0117275
MV2
5/3/18
46
A0117239
CJ5
5/3/18
84
A0117276
MV26
5/3/18
47
A0117238
CJ5-3
5/3/18
85
A0117277
MV4
5/3/18
48
A0117240
CJ5A
5/3/18
86
A0117278
MV6
513118
49
A0117241
D01 G
513/18
87
A0117279
MV8
5/3/18
50
A0117242
D02
5/3/18
88
A0117280
V12
5/3/18
51
A0117243
EB01
5/3/18
89
A0117281
V16
5/3/18
52
A0117244
EB02
5/3118
90
A0117282
V4
5/3/18
53
1 A0117245
G01 G
5/3/18
91
A0117283
V8
5/3/18
54
A0117246
G02
5/3/18
92
STDL01
STD. DETAIL
5/3118
55
A0117247
G03
5/3118
93
STDL02
STD. DETAIL
5/3/18
56
A0117248
G04
5/3/18
94
STDL03
STD. DETAIL
5/3/18
57
A0117249
G05
5/3/18
95
STDL04
STD. DETAIL
5/3/18
58
A0117250
G06G
5l3/18
96
STDL05
STD. DETAIL
5/3/18
59
A0117251
HC3
5/3/18
97
STDL06
STD. DETAIL
5/3/18
60
A0117252
HC5
5/3/18
98
STDL07
STD. DETAIL
5/3/18
61
A0117253
HJ27-3
5/3/18
99
STDL08
STD. DETAIL
5/3/18
62
A0117254
HJ36
5/3/18
100
STDL09
STD. DETAIL
5/3/18
63
A0117255
HJ5
5/3/18
101
STDL10
STD. DETAIL
5/3/18
64
A0117256
HJ5A
5/3/18
102
STDL11
STD. DETAIL
5/3/18
65
A0117257
HJ5C
5/3/18
103
STDL12
STD. DETAIL
513/18
66
A0117259
HJ7
5/3/18
104
STDL13
STD. DETAIL
5/3/18
67
A0117258
HJ7-3
5/3/18
105
STDL14
STD. DETAIL
5/3/18
68
A0117260
HJ7A
5/3/18
106
STDL15
STD. DETAIL
5/3/18
69
A0117261
J5
5/3/18
107
STDL16
STD. DETAIL
5/3/18
70
A0117262
J5A
5/3/18
71
A0117263
J5C
5/3/18
72
A0117265
J7
5/3/18
73
A0117264
J7-3
5/3/18
74
A0117266
J7A
5/3/18
Page 2 of 2
Job
Truss
Truss Type
Qty
Ply
A0117193
72005
A01AG
Half Hip Girder
1
1
s
Job.Reference o tional
Al Rbof Trusses, Fort Pierce, FL 34946, design@altruss.com
4-1
5.00 12
3x8
2
1
5x10
8.1 ZU S Nov I ZU1 r Mr I eK inausineS, inc. r nu May o uu:"I o:u4 zu-i n rage l
I D: n KM LCG99vHyLG9 D 5?YIAEyzKd3P-5Oug LWfoi IpNOrP50bxEi bogYSecsmi224 RD3 BzKG Wb
-9 , 21-3-2
3x8 II
Dead Load Dei). =1/16 in
Sx8 =
u
9
20
21 8 22
7
23
24 25
6
3x4 =
10
5x6 =
4x6 =
4x10
=
3x6 II
3x6 11
1-9-8
1 8 7-0-0
14-1-9
20-11-10
2- -2
1-9-8
-4-0 4-10-8
7-1-9
6-10-1
0-3-8
Plate Offsets (X Y)—
[5:0-3-4 0-2-12] [6:Edge 0-3-8]
[7'0-1-12 0-2-01
[10:0-4-8
0-1-81
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc)
Well
Ud
PLATES
GRIP
TCLL ' 30.0
Plate Grip DOL 1.25
TC
0.83
Vert(LL) 0.16
7-9
>999
360
MT20
244/190
TCDL 15.0
Lumber DOL 1.25
BC
0.45
Vert(CT) -0.16
7-9
>999
240
-
BCLL 0.0 '
Rep Stress Incr NO
WB
0.98
Horz(CT) -0.02
6
n/a
n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MS
Weight: 143 lb
FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except`
Wl: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 3-11-10 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing,
Except:
5-7-2 oc bracing: 7-9.
WEBS
1 Row at midpt 5-7
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
6 =
1510/Mechanical
10 =
165210-8-0 (min.0-1-15)
Max Horz
10 =
264(LC 8)
Max Uplift
6 =
-1319(LC 5)
10 =
-1350(LC 4)
Max Grav
6 =
1510(LC 1)
10 =
1652(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-2083/1814, 3-14=-2425/2205,
14-15=-2425/2205, 15-16=-2425/2205,
4-16=-2425/2205, 4-17=-2425/2205,
17-18=-2425/2205, 18-19=-2425/2205,
5-19=-2425/2205,5-6=-1393/1302
BOT CHORD
9-10=-353/129, 9-20=-1719/1828,
20-21=-1719/1828,8-21=-1719/1828,
8-22=-1719/1828, 7-22=-1719/1828
WEBS
2-10=-1.491/1265, 2-9=-1533/1744,
3-9=-202/324, 3-7=-552/690,
WEBS
2-10=-1491 /1265,
3-9=-202/324, 3-7
4-7=-1076/1173,!
NOTES-
1) Unbalanced roc
for this design.
2) Wind: ASCE 7-'
Vasd=139mph; TC
Cat. II; Exp D; Enc
cantilever left exp(
DOL=1.60
3) Provide adequa
ponding.
4) This truss has t:
chord live load nor
loads.
5) ` This truss has
20.Opsf on the bot
rectangle 3-6-0 tal
bottom chord and
6) Refer to girder(:
7) Provide mechar
to bearing plate ca
at joint 6 and 135C
8) Hanger(s) or otl
provided sufficient
lb down and 459 It
lb up at 9-0-12, 1'
112 Ito down and
and 208 lb up at 1
up at 17-0-12, am
19-0-12 on top ch(
7-0-0, 37 lb down
and 28 lb up at 11
13-0-12, 37 lb dou
lb down and 28 lb
40 lb up at 19-0-1
design/selection o
responsibility of of
9) In the LOAD C/
face of the truss ai
533/1744,
live loads have been considered
); Vult=180mph (3-second gust)
)L=5.Opsf; BCDL=5.Opsf; h=39ft;
, GCpi=0.18; MWFRS (envelope);
;ed ; Lumber DOL=1.60 plate grip
drainage to prevent water
en designed for a 10.0 psf bottom
:oncurrent with any other live
)een designed for a live load of
rm chord in all areas where a
by 2-0-0 wide will fit between the
ny other members.
I for truss to truss connections.
cal connection (by others) of truss
)able of withstanding 1319 lb uplift
lb uplift at joint 10.
er connection devices) shall be
o support concentrated load(s) 220
up at 7-0-0, 112 lb down and 208
2 lb down and 208 lb up at 11-0-12
108 lb up at 13-0-12, 112 lb down
i-0-12, and 112 lb down and 208 lb
122 lb down and 230 lb up at
'd, and 135 Ib down and 79 lb up at
nd 28 lb up at 9-0-12, 37 lb down
0-12, 37 lb down and 28 lb up at
i and 28 lb up at 15-0-12, and 37
p at 17-0-12, and 57 lb down and
Ion bottom chord. The
such connection device(s) is the
E(S) section, loads applied to the
noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-90, 3-5=-90, 6-11=-20
Concentrated Loads (lb)
Vert: 3=-150(F) 9=-18(F) 14=-83(F) 15=-83(F)
16=-83(F)17=-83(F) 18=-83(F) 19=-113(F)
20=-1 8(F) 21=-18(F) 22=-18(F)23=-18(F) 24=-18(F)
25=-47(F)
Job
Truss
Truss Type
Oty
Pty
72005
A01G
HIP GIRDER
1
2
A0117194
Job Reference o tional
Al Koor i russes, ton tierce, tL 34u4b, oesignLaitruss.com
o
4x8 ! 5x6 =
4x6 =
8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:15:11 2018 Page 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-ONpJpvkB3uhNkwRSIZZuU4brX6zu?? 14ffd5pHzKGW U
41-16'-6
5x8 = 4x8 = 5x8 =
Dead Load Defl. =114 in
M
11 r
-
0 m
1 5x6 = 4x8 II
4x6 =
41-6-8
1-9-82r3,8 7-0-0 i 11-8-13 16-3-15 i 20-11-0 i 25-6-1 30-1-3 34-10-0 i 3M8 4p-0-8 4110-0
1-&80-6'0 4.8-8 ' 4.3 ' 4i7-1 ' 4-7-1 4-7-1 4-7-1 4-8-13 4-8-8 0 011-8
1-6-0
Plate Offsets
LOADING (psf)
SPACING-
2-0-0
TCLL
30.0
Plate Grip DOL
1.25
TCDL
15.0'
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
NO
BCDL
10.0
Code FBC2017/TP12014
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1: 2x8 SP 240OF 1.8E
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-3-3 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 4-4-8 oc bracing.
REACTIONS. (lb/size)
22 =
2943/1-0-0 (min. 0-1-12)
12 =
2943/1-0-0 (min. 0-1-12)
Max Horz
22 =
97(LC 8)
Max Uplift
22 =
-4318(LC 4)
12 =
-4173(LC 4)
Max Grav
22 =
2943(LC 1)
12 =
2943(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-306/485, 2-3=4120/6445,
3-29=-6410/10121, 29-30=-6410/10121,
4-30=-6410/10121, 4-31=-7964/12507,
31-32=-7964/12507, 5-32=-7964/12507,
5-33=-8490/13323, 33-34=-8490/13323,
6-34=-8490/13323, 6-35=-8490/13323,
35-36=-8490/13323, 7-36=-8490/13323,
7-37=-7964/12521, 37-38=-7964/12521,
8-38=-7964/12521, 8-39=-6410/10148,
39-40=-6410/10148, 9-40=-6410/10148,
9-10=4120/6491, 10-11=-306/620
BOT CHORD
1-22=-460/306, 21-22=-488/306,
21-41=-5736/3667, 4142=-5736/3667,
20-42=-5736/3667, 20-43=-9925/6410,
19-43=-9925/6410, 19-44=-9925/6410,
1844=-9925/6410, 1845=-12311/7964,
4546=-12311/7964, 17-46=-12311/7964,
17-47=-12325/7964, 4748=-12325/7964,
Continued on page 2
CSI.
DEFL. in
(loc)
I/deft
Ud
TC 0.98
Vert(LL) 0.88
17
>508
360
BC 0.73
Vert(CT) 0.80
17
>562
240
WB 0.67
Horz(CT) -0.15
12
n/a
n/a
Matrix -MS
BOT CHORD
1-22=460/306, 21-22=-488/306,
I21-41=-5736/3667, 41-42=-5736/3667,
20-42=-5736/3667, 20-43=-9925/6410,
'19-43=-9925/6410, 19-44=-9925/6410,
18-44=-9925/6410, 18-45=-12311/7964,
45-46=-12311/7964, 17-46=-12311/7964,
17 47=-12325/7964, 47-48=-12325/7964,
16-48=-12325/7964, 16-49=-9952/6410,
15-49=-9952/6410, 15-50=-9952/6410,
�14-50=-9952/6410, 14-51=-5782/3667,
51-52=-5782/3667, 13-52=-5782/3667,
12-13=-576/306, 11-12=-576/306
WEBS
12-22=-2701/3851, 2-21 =-5445/3507,
13-21=-740/804, 3-20=-4980/3282,
4-20=-1654/2261,4-18=-2864/1871,
5-18=-920/1176, 5-17=-980/640,
6-17=-586/656, 7-17=-963/640,
7-16=-920/1167,8-16=-2848/1871,
8-14=-1654/2251, 9-14=-4958/3282,
9-13=-739/780, 10-13=-5369/3507,
10-12=-2701 /3782
'NOTES-
1) 2-ply truss to be connected together with 1 Od
(0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows
staggered at 0-9-0 oc. -
Bottom chords connected as follows: 2x6 - 2 rows
staggered at 0-9-0 oc.
Webs connected as follows: 2x8 - 2 rows staggered at
0-9-0 oc, 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies,
except if noted as front (F) or back (B) face in the
LOAD CASE(S) section. Ply to ply connections have
been provided to distribute only loads noted as (F) or
(B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered
for this design.
4) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf, BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; porch left exposed;
Lumber DOL=1.60 plate grip DOL=1.60
5) Provide adequate drainage to prevent water
PLATES GRIP
MT20 244/190
MT20HS 187/143
Weight: 578 Ib FT = 10%
6) All plates are MT20 plates unless otherwise
indicated.
7) All plates are 4x4 MT20 unless otherwise indicated.
8) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
9) * This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
10) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 4318 lb uplift
at joint 22 and 4173 lb uplift at joint 12.
11) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 204
lb down and 456 lb up at 7-0-0, 107 lb down and 199
lb up at 9-0-12, 107 lb down and 199 lb up at 11-0-12
, 107 lb down and 199 lb up at 13-0-12, 107 lb down
and 199 lb up at 15-0-12, 107 lb down and 199 lb up
at 17-0-12, 107 lb down and 199 lb up at 19-0-12,
107 lb down and 199 lb up at 20-11-0, 107 lb down
and 199 lb up at 22-9-4, 107 lb down and 199 lb up at
24-9-4, 107 lb down and 199 lb up at 26-9-4, 107 lb
down and 199 lb up at 28-9-4, 107 lb down and 199 lb
up at 30-9-4, and 107 lb down and 199 lb up at
32-9-4, and 204 lb down and 456 lb up at 34-10-0 on
top chord, and 207 lb down and 336 lb up at 7-0-0, 30
lb down and 147 lb up at 9-0-12, 30 lb down and 147
lb up at 11-0-12, 30 lb down and 147 lb up at 13-0-12
, 30 lb down and 147 lb up at 15-0-12, 30 lb down and
147 lb up at 17-0-12, 30 lb down and 147 lb up at
19-0-12, 30 lb down and 147 lb up at 20-11-0, 30 lb
down and 147 lb up at 22-9-4, 30 lb down and 147 lb
up at 24-9-4, 30 lb down and 147 lb up at 26-9-4, 30
lb down and 147 lb up at 28-9-4, 30 lb down and 147
lb up at 30-9-4, and 30 lb down and 147 lb up at
32-9-4, and 207 lb down and 336 lb up at 34-9-4 on
bottom chord. The design/selection of such
connection device(s) is the responsibility of others.
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-90, 3-9=-90, 9-11=-90, 23-26=-20
Job
Truss
Truss Type
Qty
P1Y
A0117194
72005
A01G
l
HIP GIRDER
1
�
a
Job Reference (optional)
Al Rbof Trusses, Fort Pierce, Fl_ ;3494ti, aesignLal truss.wm
LOAD CASE(S)
Standard
Concentrated Loads (lb)
Vert: 3=-129(B) 9=-129(B) 21=27(B) 17=-11(B)
6=-71 (B) 13=27(B) 29=-71 (B) 30=-71 (B) 31 =-71 (B)
32=-71(B) 33=-71(B) 34=-71 (B) 35=-71 (B) 36=-71 (B)
37=71(B) 38=-71(B) 39=-71(B) 40=-71(B) 41=-11(B)
42=-11(B) 43=-11(B) 44=-11(B)45=-11(B)46=-11(B)
47=11(B) 48=-11(B) 49=-11(B) 50=-11(B) 51=-11(B)
52=-11(B)
o- l4V s rvuV IL GV I / IYII I GIB II WUMI IGJ, 111-
I D:nKMLCG99vHyLG9D5?YIAEyzKd3P-ONpJpvkB3uhNkwRSIZZuU4brXGzu??14ffd5pHzKGWU
Job
Truss
Truss Type
Qty
Ply
72005
A02
Hip
1
1,
A0117195
Job Reference (optional)
... ....... ............. . ..... ......e, ..�..�.., .....+y..vu...uoo.w... 1 C ' D IVVV 11 4U I I IVII IUR IIIUU5U1e5, Inc. . nu may a uJ:-ia:"Iz Zulu rage i
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-sZNhOFlpgCgEL40esH471 H88ygYHkNUDuJNeLjzKGWT
9-0-0 15-0-1 20-11-0 26-9-15 32-10-0 39-4-8 a
0-0 62-3-8 6 8-8 6-0-1 5 10-15 5-10-15 6-0-1 6-0 8
Dead Load Defl. = 3116 in
7x10 MT20HS-
7x10 MT20HS=
4x4 = 7x10 MT20HS= 4x4 =
5.00 FiT 3 4 5 6 7
4x6 = 4x10 = 5x8 = 4x8 = 5x8 = 6x10 =
5x8 11
3x8 MT20HS I i 4x6 = 4x6 =
LIMP
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) , I/defl
L/d
PLATES
GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.49
Vert(LL)
0.65 13-14 >679
360
MT20
244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.72
Vert(CT)
0.57 13-14 >768
240
MT20HS
187/143
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.99
Horz(CT)
-0.14 9 n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 275 Ib
FT = 10%
LUMBER -
TOP CHORD 2x6 SP 2400F 2.0E
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 `Except`
W1: 2x6 SP No.2, W2: 2x4 SP No.2
W7: 2x8 SP 2400F 1.8E
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 4-7-13 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 2-2-5 oc bracing.
WEBS
1 Row at midpt
7-12, 3-14, 6-13, 4-13
2 Rows at 113 pts 2-16, 8-10
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
17 =
2287/1-0-0 (min. 0-2-11)
9 =
2015/0-8-0 (min. 0-2-6)
Max Horz
17 =
190(LC 12)
Max Uplift
17 =
-2499(LC 8)
9 =
-2251(LC 8)
Max Grav
17 =
2287(LC 1)
9 =
2015(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-351/800, 2-3=-3228/6548,
3-4=-4346/9200,4-5=-4805/10151,
5-6=-4805/10151, 6-7=-4291/9078,
7-8=-3100/6298, 8-9=-1932/3843
BOT CHORD
1-17=-797/404, 16-17=-962/404,
15-16=-5820/2848, 14-15=-5820/2848,
13-14=-8828/4346, 12-13=-8706/4291,
11 - 1 2=-5591/2747, 10-11=-5591/2747,
9-10=-772/359
WEBS
2-17=-2102/3974, 2-16=4920/2478,
WEBS
2-17=2102/3974, 2-16=-4920/2478,
3-16=-289/291,7-10=-372/349,
8-10=-4918/2439, 7-12=-3717/1925,
' 3-14=-3590/1871, 6-12=-934/1429,
4-14=-901/1353,6-13=-1284/668,
4-13=-1138/602, 5-13=-523/718
'NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=S.Opsf; h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;
porch left exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) All plates are MT20 plates unless otherwise
indicated.
5) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
6) - This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 2499 lb uplift
at joint 17 and 2251 lb uplift at joint 9.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
A0117196
72005
A02A
Half Hip
1
1
q
Job Referenceo tional
Al KOOi busses, rOn r-jerce, rL J4y40, aesIgn((Ld I❑uss.WnI
5.00 F12
2
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-LIx4EbmRaWyi zDbgQ_cMaVgDF4ebTxwN7z6CuAzKGWS
15-1-9 21-3-2
5x10
3x6 11 $ftdioad Defl. = 1 /16 in
3 4 5
10 9
Us= 4x16 11 2x4 ill
1-9-8
8 7
4x6 = 6
3x10 = 3x6 11
-9
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
TCLL 30.0
Plate Grip DOL
1.25
TC 0.84
Vert(LL)
0.13
7-9
>999
360
TCDL 15.0
Lumber DOL
1.25
BC 0.78
Vert(CT)
-0.16
7-9
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.53
Horz(CT)
0.02
6
n/a
n/a
BCDL 10.0
Code FBC20171FP12014
Matrix -MS
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 `Except'
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-1-5 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 5-9-5 oc bracing.
WEBS
1 Row at midpt 5-7
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
6 = 1031/Mechanical
10 = 1295/0-8-0 (min. 0-1-8)
Max Horz
10 = 339(LC 12)
Max Uplift
6 =-652(LC 9)
10 =-741(LC 8)
Max Grav
6 = 1031(LC 1)
10 = 1295(LC 1)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-1048/638, 2-3=-1366/1244,
3-4=-1191/1283, 4-5=-119111283,
5-6=-980/1118
BOT CHORD
1 -1 0=-756/1111, 9-1 0=-1 294/1111,
8-9=-1286/1110, 7-8=-128611110
WEBS
4-7=-656/849, 5-7=-1505/1396,
2-10=-925/1502
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-1
Vasd=139mph; TC
Cat. II; Exp D; Encl
and C-C Exterior(2
for members and b
shown; Lumber DC
3) Provide adequal
ponding.
4) This truss has b
chord live load non
loads.
5) ` This truss has
20.Opsf on the bott
rectangle 3-6-0 tall
bottom chord and r
6) Refer to girder(s
7) Provide mechan
to bearing plate ca.
joint 6 and 741 lb L
LOAD CASE(S)
Standard
Vult=180mph (3-second gust)
iL=5.Opsf; BCDL=5.Opsf; h=39ft;
GCpi=0.18; MWFRS (envelope)
zone; cantilever left exposed ;C-C
ces & MWFRS for reactions
=1.60 plate grip DOL=1.60
drainage to prevent water
designed for a 10.0 psf bottom
current with any other live
een designed for a live load of
m chord in all areas where a
iy 2-0-0 wide will fit between the
iy other members.
for truss to truss connections.
:al connection (by others) of truss
able of withstanding 652 lb uplift at
lift at joint 10.
PLATES GRIP
MT20 244/190
Weight: 138 Ib FT = 10%
Job
Truss
Truss Type
Qty
Ply
72005
A03
Hip
1
1
A0117197
Job Reference (optional)
Root I cusses, Fort Pierce, FIL 34946, design@aitruss.com 1 8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:15:14 2018 Page 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-pyVSRxn3Lp4ybNAOzh7b6iDMrLrOtClf WMdsIQczKGWR
0 Q 0 6 9A 11-0-0 17-7-15 24-2-1 30-10-0 35-0-12 39 4-8
0- 6 6-9 4 4-2-12 6-7-15 6-6-3 6-7-15 %-12 4-3-12
7x10 MT20HS=
-nnFiq
3x6 II 7x10 MT20HS WB= 6x6 =
7x10 MT20HS=
Dead Load Defl. =1/8 in
4x6 = 7x8 = 4x4 = 5x8 = 4x8 = 4x4 = 5x8 = 4x4 = 8x10 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defl
L/d
PLATES
GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.97
Vert(LL)
0.52 14-15
>855
360
MT20
244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.65
Vert(CT)
0.46 14-15
>966
240
MT20HS
187/143
BCLL 0.0
Rep Stress Incr
YES
WB 0.95
Horz(CT)
-0.17 11
n/a
n/a
BCDL 10.0
Code FBC20171TP12014
Matrix -MS
Weight: 283 lb
FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2 *Except*
T2: 2x6 SP 240OF 2.0E
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W2,W6: 2x4 SP No.2, W1: 2x6 SP No.2
W7: 2x8 SP 240OF 1.8E
OTHERS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 2-3-13 oc bracing.
WEBS
1 Row at midpt
3-18, 8-14, 4-15, 9-11
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
18 =
2287/1-0-0 (min.0-2-11)
11 =
2015/0-8-0 (min.0-2-6)
Max Horz
18 =
218(LC 12)
Max Uplift
18 =
-2453(LC 8)
11 =
-2205(LC 8)
Max Grav
18 =
2287(LC 1)
11 =
2015(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-240/661, 2-3=-357/996,
3-4=-3141/6667, 4-5=-3873/8315,
5-6=-3873/8315, 6-7=-3873/8315,
7-8=-3848/8255, 8-9=-3068/6503,
9-10=-367/880, 10-11=-333/679
BOT CHORD
1-18=-598/248, 17-18=-5249/2582,
16-17=-5812/2851, 15-16=-5812/2851,
14-15=-7765/3848, 13-14=-5654/2780,
12-13=-5654/2780, 11-12=-4851/2409
BOT CHORD
1-18=-598/248, 17-18=-5249/2582,
116-17=-5812/2851, 15-16=-5812/2851,
14-15=-7765/3848, 13-14=-5654/2780,
j 12-13=-5654/2780, 11-12=-4851/2409
'WEBS
3-17=-653/482, 4-17=-434/151,
8-12=-307/187, 3-18=-2817/5376,
2-18=-534/831, 8-14=-2586/1410,
4-15=-2466/1357, 7-14=-695/862,,
5-15=-621/820, 9-11=-2676/5220,
9-12=-943/596
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf, h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;
porch left exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) All plates are MT20 plates unless otherwise
indicated.
5) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
6) * This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 2453 lb uplift
at joint 18 and 2205 lb uplift at joint 11.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
City
Ply
A0117198
72005
A03A
Half Hip
1
1
Job Reference (optional)
Al Keor I cusses, rorr Ylerce, r"L AU1+0, aes,gn((Ld I UU55.WF11
ID:nKMLCG99vHyLG;D5?YIAEy iZd3P-pyVSRxn3Lp4ybNAOzh7b6iDNnU1xClaWMdslQczKGWR
16-1-9 21-3-2 _ J
5-1-9 5-1-9
Dead Load Defl. =1/8 in
6x6 =
3x8 = 4x16 I 3x8 =
2r1r8
11-0-0
20-11-10
1 9 8 0-4-0
8-10-8
9-11-10
0-3-8
Plate Offsets (X Y)—
[7.0-3-0 0-4-8] [10.0-0-15 Edge]
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc)
I/deft
L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.91
Vert(LL) 0.12
7-9
>999
360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.58
Vert(CT) -0.20
7-9
>999
240
BCLL 0.0 *
Rep Stress Incr YES
WB 0.95
Horz(CT) -0.02
7
n/a
n/a
BCDL 10.0
Code FBC2017fTP12014
Matrix -MS
Weight: 143 Ib FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 5-3-7 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
7 =
1031/Mechanical
10 = 1295/0-8-0 (min.0-1-8)
Max Horz
10 =
413(LC 12)
Max Uplift
7 =
-646(LC 9)
10 =
-701(LC 8)
Max Grav
7 =
1031(LC 1)
10 =
1295(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-997/695, 2-3=-1377/1314,
3-4=-1174/1128, 4-5=-1053/1190
BOT CHORD
1-10=-840/1107,9-10=-1495/1107,
8-9=-965/805, 7-8=-965/805
WEBS
3-9=-153/350, 2-1 0=-1 089/1567,
5-9=-309/376, 5-7=-1082/1315
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-1
Vasd=139mph;TC
Cat. II; Exp D; Enc'
and C-C Exterior(2
for members and fi
shown; Lumber DC
3) Provide adequal
ponding.
4) This truss has b
chord live load nor
loads.
5) * This truss has
20.Opsf on the bott
rectangle 3-6-0 tall
bottom chord and:
6) Refer to girder(s
7) Provide mechar
to bearing plate ca
joint 7 and 701 lb L
LOAD CASE(S)
Standard
Vult=180mph (3-second gust)
iL=5.Opsf; BCDL=5.Opsf; h=39ft;
GCpi=0.18; MWFRS (envelope)
zone; cantilever left exposed ;C-C
ces &MWFRS for reactions
=1.60 plate grip DOL=1.60
drainage to prevent water
designed for a 10.0 psf bottom
current with any other live
:n designed for a live load of
chord in all areas where a
2-0-0 wide will fit between the
other members.
r truss to truss connections.
connection (by others) of truss
le of withstanding 646 lb uplift at
t at joint 10.
Job
Truss
Truss Type
Qty
Ply
72005
A04
Half H,ip
2
1
A0117199
Job Reference (optional)
r i Ruin "ubses, roar rien:e, rL awawo, uesignLa-icross.com - 8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:15:15 2018 Page 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-H83geHnh67CpCXIDXPegfwmZLtMd3xskgaHbJylzKG WQ
0 Q 0 10-1-6 13-0-0 21-3-2 a
0: 6 10-1-6 2-10-10 8-3-2
5x8 =
3x6 11
Dead Load Deft. = 3116 in
4x16 11 3x4 = 4x6 = 6x6 =
3x8 =
$1T8 10-1-6 13-0-0 20-11-10 21-3-2
1-9-R n_d-n 7-11-1d 9_1 rL1n 7 4� 4n
Plate Offsets (X,Y)— (6:0-3-0,0-4-81, (9:0-0-15,Edgel
I
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.86
Vert(LL) -0.14 6-8 >999 360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.59
Vert(CT) -0.32 6-8 >717 240
BCLL 0.0
Rep Stress Incr YES
WB 0.51
Horz(CT) -0.02 6 n/a n/a
BCDL 10.0
Code FBC20171TP12014
Matrix -MS
Weight: 140 Ib FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 4-7-10 oc
pudins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 5=9-10 oc bracing.
WEBS
1 Row at midpt 4-6
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
6 =
1031/Mechanical
9 =
1295/0-8-0 (min. 0-1-8)
Max Horz
9 =
488(LC 12)
Max Uplift
6 =
-637(LC 9)
9 =
-689(LC 12)
Max Grav
6 =
1031(LC 1)
9 =
1295(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-1001/490, 2-3=-1380/1150,
3-4=-1224/1463, 5-6=-343/463
BOT CHORD
1-9=-652/1109, 8-9=-1 426/1109,
7-8=-1113/875, 7-13=-1113/875,
13-14=-1113/875, 6-14=-1113/875
WEBS
2-9=-1086/1636, 3-8=-387/782,
4-8=-679/627, 4-6=-1020/1315
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf, BCDL=5.Opsf, h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water
ponding.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
4) ' This truss has been designed for a live load of
20.Opsf'on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
10.0psf.
5) Refer to girder(s).for truss to truss connections.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 637 lb uplift at
joint 6 and 689 lb uplift at joint 9.
LOAD CASE(S)
Standard
Job
Truss
Truss Type I
Qty
Ply
A0117200
72005
A05
Half Hip
1
1
y
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com
2-1-8 , 4-7.8
8.120 s Nov 12 2017 MiTek Industries,- Inc. Thu May 3 09:16:16 2018 Page 1
ivLG9D5?YIAEvzKd3P-IKdCscoKtRKaahKP5693B711c1 HfKaCvaaxLsU UzKGW P
Io
0
3x4 = 6x6 = 2x4 11 2x4 I I 3x6 11
4x6 =
2a-11-10
Dead Load Defl. = 1/16 in
Plate Offsets (X Y)—
[4:0-3-0 Edae] [8:0-4-8 0-1-8] [13:0-3-0 0-4-8]
[14:0-5-8 0-2-81
[17:0-3-0,04-81
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL in (loc)
I/deft
Ud
PLATES
GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC
0.81
Vert(LL) 0.14 15
>999
360
MT20
244/190
TCDL 15.0
Lumber DOL 1.25
BC
0.78
Vert(CT) -0.14 13-14
>999
240
MT20HS
1871143
BCLL 0.0 '
Rep Stress Incr YES
WB
0.90
Horz(CT) 0.09 8
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 164 lb
FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2 *Except`
B2,B6: 2x4 SP No.3
WEBS 2x4 SP No.3 `Except'
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-0-13 oc
puriins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 3-11-3 oc bracing.
Except:
6-0-0 oc bracing: 14-16
WEBS
1 Row at midpt 3-13, 6-10
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
8 =
1040/Mechanical
17 =
1304/0-8-0 (min.0-1-9)
Max Horz
17 =
562(LC 12)
Max Uplift
8 =
-621(LC 9)
17 =
-686(LC 12)
Max Grav
8 =
1040(LC 1)
17 =
1304(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-396/83, 2-3=-2064/2435,
3-4=-1509/1324, 4-5=-1375/1344,
5-6=-1493/1837, 8-10=-1015/1226,
7-10=-263/354
BOT CHORD
1-17=-42/423, 16-17=-338/213,
13-14=-3290/2352, 13-21 =-1 043/812,
21-22=-1043/812, 11-22=-1043/812,
10-11=-1048/807
WEBS
2-17=-1 001 /1344, 3-13=-1109/1662,
WEBS
2-17=-1 001 /1344, 3 13=-1109/1662,
5-13=-667/1164, 6-13=-1421/1126,
6-10=-1052/1370, 114-17=-310/68,
2-14=-2503/1917 1
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf, BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl.I GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2)�zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water
ponding.
3) All plates are MT20 plates unless otherwise
indicated.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) ' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
10.Opsf.
6) Refer to girder(s) ifor truss to truss connections.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 621 lb uplift at
joint 8 and 686 lb uplift at joint 17.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
City
Ply
A0117201
72005
A05A
ATTIC
1
1
Job Reference o tional
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com
10-1-6
8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 0r9:15:17 2018
Dead Load Defl. =114 in
4x4 = 3x8 11 7x6 = 3x8 11 8x8 =
1-9-8 2r1r8 10-1-6 18-4-14 20-11-121 0,-$-2
1-9 8 0 IL 7-11-14 8-3-8 2 6 12 0 3 8
Plate Offsets (X,Y)— [1:0-1-15,Edge], f2:0-2-12,0-4-4], f3:0=3-O,Edge], [5:Edge,0-6-31, [8:0-3-0,0-4-0], [9:Edge,0-4-8], [11:0-3-0,0-4-12], [12:04-9,0-1-71, [14:0-6-0,0-1-12]
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defl
Ud
PLATES GRIP
TCLL
30.0
Plate Grip DOL
1.25
TC 0.88
Vert(LL)
0.53 11-12
>433
360
MT20 244/190
TCDL
15.0
Lumber DOL
1.25
BC 0.80
Vert(CT)
-0.52 11
>442
240
BCLL
0.0 '
Rep Stress Incr
YES
i WB 0.79
Horz(CT)
-0.02 9
n/a
n/a
BCDL
10.0
Code FBC2017/TPI2014
Matrix -MS
Attic
-0.15 10-11
694
360
Weight: 161 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2 *Except*
T3: 2x6 SP 240OF 2.0E
BOT CHORD 2x6 SP No.2 'Except'
B2: 2x6 SP 240OF 2.0E
WEBS 2x4 SP No.3 `Except'
W4: 2x4 SP No.2, W1: 2x6 SP No.2
OTHERS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 3-11-10 oc bracing.
WEBS
1 Row at midpt 5-14, 9-14
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
9 =
1093/Mechanical
12 =
1333/0-8-0 (min. 0-1-9)
Max Horz
12 =
562(LC 12)
Max Uplift
9 =
-563(LC 9)
12 =
-653(LC 12)
Max Grav
9 =
1194(LC 2)
12 =
1333(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-657/406, 2-3=-1307/690,
3-4=-1138/698, 4-18=-1060/875,
5-18=-957/896, 5-6=-1825/1419,
6-7=-1851/1457, 7-8=-2052/1599,
8-9=-906/749
BOT CHORD
1-12=-566/734, 11-12=-1458/1033,
10-11 =-1 113/1049, 9-1 0=-1 087/1015
WEBS
2-11=-98/531, 4-11=-134/393,
10-14=-501/884, 7-14=-1123/1414,
WEBS
2-11=-98/531, 4-11 =- 134/393,
10-14=-501 /884, 7-14=-1123/1414,
5-13=2444/2987, 13-14=-2424/2964,
2-12=-1108/1524, 8-14=-1656/2125,
9-14=2478/2656
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf, h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Extedor(2) zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) 100.01b AC unit load placed on the top chord,
14-0-0 from left end, supported at two points, 2-0-0
apart.
4) Provide adequate drainage to prevent water
ponding.
5) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
6)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
7) Bottom chord live load (30.0 psf) and additional
bottom chord dead load (0.0 psf) applied only to room.
10-11
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 563 lb uplift at
joint 9 and 653 lb uplift at joint 12.
10) ATTIC SPACE SHOWN IS DESIGNED AS
UNINHABITABLE.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
A0117202
72005
A06
Half Hip
1
1
�
Job Reference (optional)
Al KOot I cusses, t-ori vierce, rL 14y40, aesignLa ni uss.Wui
0-0-02-1-8 , 4-7.8
6x6
4
4x8
4x8 3
G9D5?YIAEyzKd3P-hjlzH IgaP2aN3?ToCXBXHY05E5LP8506GFgzZNZKGWN
5x8 = 2x4 11
6 7 Dead Load Defl. = 1/16 in
5.00 12
3x8 I I
5
14 1 �-101 1
13 rT- '����{� 4x4 = Io
21 22 .- _ -
17 16 ILIJ
15 7x8 = 9 8
12 3x6 II
6x6 = 2x4 11 2x4 11
3x4 = Sx10 MT20HS=
19-2-0 21-3-2
1-9.8 2 1 8 4-3-0 4 7 8 12-5-10
1-9-8 0-4-0 2-2-8 7-10.2 1
17-0-0 - 18-10-8 20-11-1 U
4.6.6 1-10-80-3-81-9.100-3-8
Plate Offsets (X Y)—
[4.0 3 0 Edgel [8-0-4-8 0-1-8] [13.0-3-0 0-4-8] [14.0-5-12 0-2-8] [17.0-3-0 0-4-81
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/deft
L/d
PLATES
GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.76
Vert(LL)
0.15 13-14
>999
360
MT20
244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.80
Vert(CT)
-0.14 13-14
>999
240
MT20HS
187/143
BCLL 0.0
Rep Stress Incr YES
WB 0.96
Horz(CT)
0.09 8
n/a
n/a
BCDL 10.0
Code FBC2017fTP12014
Matrix -MS
Weight: 167 Ib
FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2 `Except`
B2,B6: 2x4 SP No.3
WEBS 2x4 SP No.3 `Except`
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-0-10 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 3-10-1 oc bracing.
Except:
6-0-0 oc bracing: 14-16
WEBS
1 Row at midpt
7-8, 3-13, 6-13
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation Quide.
REACTIONS. (lb/size)
8 = 1040/Mechanical
17 = 1304/0-8-0 (min.0-1-9)
Max Horz
17 = 637(LC 12)
Max Uplift
8 =-649(LC 12)
17 =-677(LC 12)
Max Grav
8 = 1040(LC 1)
17 = 1304(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-404/83, 2-3=-2065/2460,
3-4=-1508/1258, 4-5=-1374/1278,
5-6=-1513/1806, 8-1 0=-1 016/1284
BOT CHORD
1-17=-42/430, 16-17=-353/219,
13-14=-342812409,13-21=-719/529,
21-22=-719/529, 11-22=-719/529,
10-11=-721 /521
WEBS
2-17=-1001/1361, 3-13=-1139/1741,
WEBS 1
2-17=-1001/1361, 3-13=-1139/1741,
5-13=-701/1231, 6 13=-1691/1309,
6-10=-937/1297, 14-17=-342/104,
2-14=-2532/1918 1
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encll, GCpi=0.18; MWFRS (envelope)
and C-C Exterior(21 zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions
shown; Lumber DO�=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) All plates are M I u plates unless otherwise
indicated.
5) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
6) - This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
10.Opsf.
7) Refer to girder(s) � for truss to truss connections.
8) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 649 lb uplift at
joint 8 and 677 lb uplift at joint 17.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
72005
A06A
ATTIC
1
1
A0117203
Job Reference (optional)
A i Ruui i russes, ran Pierce, FL 34946, aesign@aitruss.com , 8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:15:19 2018
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-9vILUegCAMiEh82 mFimpmwDKVeStboFVvZW5F
AN0-4 a 10-1-6 17-0-0 18-4-14 21-3-2 —
i 10-1� s 10 10 1-4-1a z-10-4
5x6 ; 3x8 II 6x6 =
Dead Load Defl. = 3/16 in
4x4 = 3x8 11 7x6 = 2x4 11 8x8 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
Ud
PLATES
GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.93
Vert(LL)
0.45 11-12
>502
360
MT20
244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.96
Vert(CT)
-0.47 10-11
>486
240
MT20HS
187/143
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.83
Horz(CT)
-0.02 9
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
! Matrix -MS
Attic
-0.14 10-11
720
360
Weight: 165 Ib
FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 `Except`
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
puriins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS
1 Row at midpt
8-9, 5-13, 9-13
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
9 =
1093/Mechanical
12 =
1333/0-8-0 (min. 0-1-9)
Max Horz
12 =
637(LC 12)
Max Uplift
9 =
-591(LC 12)
12 =
-644(LC 12)
Max Grav
9 =
1194(LC 2)
12 =
1333(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
TOP CHORD
1-2=-591/360, 2-3=-1348/660,
3-4=-1171/668,4-17=-10611793,
5-17=-958/814, 5-18=-1737/1296,
6-18=-1711/1349,6-7=-2083/1647,
7-8=-2059/1625, 8-9=-1096/896
BOT CHORD
1-12=-513/697, 11-12=-1524/1035,
10-11=-1192/1077, 9-1 0=-1 181/1065
WEBS
2-11=-47/570, 4-11=-39/267,
10-13=-266(714, 7-13=-409/565,
5-13=-2271/2757,2-12=-1228/1634,
8-13=-1866/2363, 9-13=-2507/2777,
WEBS
2-11=-47/570, 4-11=-39/267,
10-13=-266/714, 7-13=-409/565,
5-13=-2271/2757, 2-12=-1228/1634,
8-13=-1866/2363, 9-13=-2507/2777,
6-13=-578/751
r
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
1 2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.OpsF, h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) 100.01b AC unit load placed on the top chord,
14-0-0 from left end, supported at two points, 2-0-0
apart.
4) Provide adequate drainage to prevent water
ponding.
5) All plates are MT20 plates unless otherwise
indicated.
6) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads. ,
7) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
8) Bottom chord live load (30.0 psf) and additional
bottom chord dead load (0.0 psf) applied only to room.
10-11
9) Refer to girder(s) for truss to truss connections.
10) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 591 lb uplift at
joint 9 and 644 lb uplift at joint 12.
11) ATTIC SPACE SHOWN IS DESIGNED AS
UNINHABITABLE.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
A0117204
72005
AO7
Half Hip
1
1
v
Job Reference o tional
Al KDOT i NSSes, ton: vierce, rL 0 tKU, oesign(aa I uuss.wrn
` 7 16 15
3x4 = 6x6 = 2x4 11
ID:nKMLCG99vHyLG9D5?YIAEyzd5sjiVrgxfg5JldAKyE?IzTNwu2hc41PkZJ4dGzKGWL
21-3.2
4x6 11 4x6 11
5.00 12 6 7
'f
6x6
5
6x6
4 W6
4x6
3x8 !:�- 3
1r '�'}�-8510j'I 4x6
13 �-yx4-�-='
7x6 = 12 9 8
220;111-AX6nn
Dead Load Defl. =1116 in
02
1-9-10
Plate Offsets (X Y)— [4:0-3-0 Edge] [5:0-3-0 0-4-01 f7:Edge 0-3-8] [8:0-4-8 0-1-8]
[13:0-3-0,0-4-81, [14:0-5-8,0-2-81, [17:0-3-0,0-4-81
LOADING(psf)
SPACING- 2-0-0
CS1.
DEFL. in (loc) 1/defl
Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 1.00
Vert(LL) 0.15 13-14 >999
360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.75
Vert(CT) -0.14 13-14 >999
240
MT20HS 187/143
BCLL 0.0
Rep Stress Incr YES
WB 0.70
Horz(CT) -0.09 8 n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 1621b FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2 *Except*
WEBS
B2,B6: 2x4 SP No.3
2-17=-1029/1418, 3-13=-1013/1546,
WEBS 2x4 SP No.3 *Except`
5-13=-79/455, 14-#=-416/170,
W1: 2x6 SP No.2
2-14=-2414/1837,-10=-1465/2004
BRACING -
TOP CHORD
NOTES -
Structural wood sheathing directly applied, except end
1) Unbalanced roo live loads have been considered
verticals.
for this design.
BOT CHORD
2) Wind: ASCE 7-1 • Vult=180mph (3-second gust)
Rigid ceiling directly applied or 3-10-8 oc bracing.
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Except:
Cat. II; Exp D; Encll�, GCpi=0.18; MWFRS (envelope)
6-0-0 oc bracing: 14-16
and C-C Extedor(2) zone; cantilever left exposed ;C-C
WEBS
for members and forces & MWFRS for reactions
1 Row at midpt
shown; Lumber DOL=1.60 plate grip DOL=1.60
7-8, 3-13, 5-10
3) Provide adequate drainage to prevent water
iTek recommends that Stabilizers and required
ponding.
[crossbracing be installed during truss erection, in
4) All plates are M 20 plates unless otherwise
ccordance with Stabilizer Installation guide.
indicated.
5) This truss has been designed for a 10.0 psf bottom
REACTIONS. (lb/size)
chord live load nonconcurrent with any other live
8 = 1040/Mechanical
loads.
17 = 1304/0-8-0 (min. 0-1-9)
6) . This truss has been designed for a live load of
Max Horz
20.Opsf on the bottom chord in all areas where a
17 = 712(LC 12)
rectangle 3-6-0 tall �y 2-0-0 wide will fit between the
Max Uplift
bottom chord and any other members.
8 =-734(LC 12)
7) Refer to girder(s) for truss to truss connections.
17 =-658(LC 12)
8) Provide mechanical connection (by others) of truss
Max Grav
to bearing plate capable of withstanding 734 lb uplift at
8 = 1040(LC 1)
joint 8 and 658 lb uplift at joint 17.
17 = 1304(LC 1)
FORCES. (lb) LOAD CASE(S)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except Standard
when shown.
TOP CHORD
1-2=-406179, 2-3=-2005/2372,
3-4=-1556/1253, 4-5=-1298/1273,
8-10=-1013/1343, 7-10=-309/474
BOT CHORD
1-17=-33/422, 16-17=-336/207,
13-14=-3376/2359, 11-13=-1836/1341, 1
10-11=-186511344
WEBS
2-17=-1029/1418,3-13=-1013/1546,
5-13=-79/455, 14-17=-416/170,
Job
Truss
Truss Type
Qty
Ply
72005
A07A
ATTIC
1
1
A0117205
Al Rnnf T-- Pnrf Pi-
r=i aeons ae..,,.,..,..,....__
-,._ I
Job Reference o tional
o. 1zu s Ivov iz zu1 f rim I eK Industries, Inc. Thu May 3 09:15:20 2018 Page 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-d5sji_rgxfg5J IdAKyE?MzTO4u_lc?UPkZJ4dGzKGWL
0- 0 10-4
18-4-14 1 - 021-3-2 •�-
0 1 10.1-6 8-3-8 7- 2-3-2
4x6 = 6x6 =
3x8 I I
5.00 12 I 6 7 8
3id10 = .1
7x10 MT20HS- 2x4 II 17
4 i
6x6
Dead Load Dell. = 3/16 in
o
12
11
10 9
3x8 11
7x6
=
2x4 11 10x10 =
4x4 = 2-1-8
2132
1 -9-8
10-1.6
18-4-14
20-11-10
1-9-8
1-11-14
838
8
04-0
Plate Offsets (X Y)--
(1:0-2-3 Edge] [2:0-2-12 0-4-4]f3.0-5,0 Edge]f5.0-2-1 0-0-01 f7.0-3-0
0-0-41 f11.0 3 0 0-4 81 f12.0-4 10 0 1 51 f13.0 2 12 0 1-41
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc)
I/deft Ud
PLATES
GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.93
Vert(LL) 0.46 11-12>494
360
MT20
244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.97
Vert(CT) -0.47 10-11
>481 240
MT20HS
187/143
BCLL 0.0
Rep Stress Incr YES
1 WB 0.99
Horz(CT) -0.02 9
n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Attic -0.14 10-11
711 360
Weight: 165 Ib
FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
pudins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS
1 Row at midpt 8-9, 9-13
JOINTS
1 Brace at Jt(s): 13
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
9 =
1093/Mechanical
12 =
133310-8-0 (min. 0-1-9)
Max Horz
12 =
712(LC 12)
Max Uplift
9 =
-676(LC 12)
12 =
-625(LC 12)
Max Grav
9 =
1194(LC 2)
12 =
1333(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-590/355, 2-3=-1344/565,
3-4=-1 166/573, 4-17=-1 057/695,
5-17=-954/715, 5-18=-1776/1259,
6-18=-1 750/1331, 6-7=-1 355/1075,
7-8=-1507/1184, 8-9=-1165/942
BOT CHORD
1-12=-506/701, 11-12=-1635/1077,
10-11 =-1 22111072, 9-1 0=-1 207/1050
WEBS
2-11=-76/569, 4-11=-39/265,
10-13=-271/718, 6-13=-718/1024,
5-13=-2164/2693,2-12=-1228/1596,
WEBS
2-11=-76/569, 4-11=-39/265,
10-13=-271/718, 6-13=-718/1024,
5-13=-2164/2693, 2-12=-1228/1596,
8-13=-1601/2037, 9-13=-2536/2911
1NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
, Vasd=139mph; TCDL=5.Opsf, BCDL=5.Opsf, h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
,3) 100.01b AC unit load placed on the top chord,
14-0-0 from left end, supported at two points, 2-0-0
apart.
4) Provide adequate drainage to prevent water
ponding.
5) All plates are MT20 plates unless otherwise
indicated.
6) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
7)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
8) Bottom chord live load (30.0 psf) and additional
bottom chord dead load (0.0 psf) applied only to room.
10-11
9) Refer to girder(s) for truss to truss connections.
10) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 676 lb uplift at
joint 9 and 625 lb uplift at joint 12.
11) ATTIC SPACE SHOWN IS DESIGNED AS
UNINHABITABLE.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
A0117206
72005
A08
Half Hip
4
1
Job Reference (optional)
Al K6or I cusses, port Fierce, M s4a4c, oesignLa_irruss.wrn �. <� •�• <<� •,"���•• .. .. �, . _-.- . -_- .
I D:nKMLCG99vHyLG9D5?YIAEyzKd3P-61Q5vKsSizyywSCNuglEuB?YgIMYLXGYzD2dAizKGW K
2-1-8 21-3-2
2-1-8 04-2
5.00 12 6
6x6
5
6x6
W6
4x6 14 `"
3x8 O 3
1
3 12 1 4x4 = o
d 5x10 M
16 15 14 7x6 = 11 8 7
3x4 = 6x6 = 2x4 I I Us € €
2x4 II
2x4 11
2-1-8 20-1'120-3-2
. -aa.. a-&ne.7-11 1a-10-a 10,2-020-11,10
LOADING (psf)
TCLL 30.0
TCDL 15.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/rP12014
CSI.
TIC 0.99
BC 0.77
WB 0.70
Matrix -MS
DEFL. in (loc) I/defl
Vert(LL) 0.15 12-13 >999
Vert(CT) -0.14 12-13 >999
Horz(CT) -0.10 7 n/a
Ud
360
240
n/a
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2 `Except`
WEBS
B2,B6: 2x4 SP No.3
2-16=1028/1421, 3-12=-1036/1624,
WEBS 2x4 SP No.3 `Except`
5-12=-100/458, 13-I1I6=-517/207,
W1: 2x6 SP No.2
2-13=-2415/1839, 5-9=-1494/2059
BRACING -
TOP CHORD
NOTES -
Structural wood sheathing directly applied, except end
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
verticals.
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
BOT CHORD
Cat. II; Exp D; Encl 1, GCpi=0.18; MWFRS (envelope)
Rigid ceiling directly applied or 3-9-11 oc bracing.
and C-C Exterior(2)I1I zone; cantilever left exposed ;C-C
Except:
for members and forces & MWFRS for reactions
6-0-0 oc bracing: 13-15
shown; Lumber DOL=1.60 plate grip DOL=1.60
WEBS
2) All plates are MT20 plates unless otherwise
1 Row at midpt 6-7, 3-12, 5-9
indicated.
MiTek recommends that Stabilizers and required
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
loads.
4) ` This truss has been designed for a live load of
REACTIONS. (lb/size)
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
7 = 1040/Mechanical
bottom chord and a y other members.
16 = 130410-8-0 (min. 0-1-9)
Max Horz
5) Refer to girder(s)lfor truss to truss connections.
16 = 789(LC 12)
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 834 lb uplift at
Max Uplift
7 =-834(LC 12)
joint 7 and 627 lb uplift at joint 16.
16 =-627(LC 12)
Max Grav 1040 LC 1
LOAD CASE(S)
16 = 1304(LC 1)
Standard
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=416/79, 2-3=-2007/2363,
3-4=-1557/1150,4-5=-1299/1170,
7-9=-1022/1422, 6-9=-307/533
BOT CHORD
1-16=-35/432, 15-16=-352/213,
12-13=-3481 /2395, 10-12=-1863/1354,
9-10=-1868/1342
WEBS
2-16=-1028/1421, 3-12=-1036/1624,
5-12=-100/458, 13-16=-517/207,
2-13=-2415/1839, 5-9=-1494/2059 j
Dead Load Defl. = 1116 in
PLATES GRIP
MT20 244/190
MT20HS . 187/143
Weight: 163 Ib FT = 10%
Job
Truss
Truss Type
Qty
Ply
72005
A08A
ATTIC
1
1
A0.117207
Job Reference (optional)
Ruin i pusses, run Pierce, rL owawo, oesign@a-iEruss.com 8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:15:22 2018 Page 1
I D: nKM LCG99vHyLG9D5?YIAEyzKd3 P-aU_T6 gt4TH4pYcnZRNGTROS'kiife4xji BtoAi8zKG WJ
0 0 10-1-6 18-4-14 z1-0-oz1 2 ^1S
0 6 10-1-6 8-3-8 2-7-2 0- 2
5.00112
->,4 11
4x4 = 3x8 11 7x6 = 2x4 11 10x10 =
Dead Load Defl. = 3116 in
2-1-8
1-0-8
1-m
04-0
10-1-6
7-11-14
18-4-14
8-3.8
21-3-2
20-11-10
2-&12 048
Plate Offsets (X,Y)—
[1:0-2-3,Edgel, [2:0-2-12,0-4-4] [3:0-5-0 Edge]
[5:0-2-1 0-0-01 [10:0-3-0 0-4-8] [11:0-4-9 0-1-8] [12.0-2-8
0-0-121
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc)
I/deft
Ud
PLATES
GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC
0.92
Vert(LL) 0.47
10-11
>480
360
MT20
2441190
TCDL 15.0
Lumber DOL 1.25
BC
0.97
Vert(CT) -0.48
9-10
>475
240
MT20HS
187/143
BCLL 0.0 '
Rep Stress Incr YES
WB
0.88
Horz(CT) -0.02
8
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
I Matrix
-MS
Attic -0.14
9-10
704
360
Weight: 168 lb
FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS
1 Row at midpt
7-8, 5-12, 8-12
JOINTS
1 Brace at Jt(s): 12
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
8 =
1093/Mechanical
11 =
133310-8-0 (min.0-1-9)
Max Horz
11 =
789(LC 12)
Max Uplift
8 =
-776(LC 12)
11 =
-594(LC 12)
Max Grav
8 =
1194(LC 2)
11 =
1333(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-589/349,2-3=-1342/451,
3-4=-1 165/459,4-16=-1057/579,
5-16=-954/600, 5-17=1965/1345,
6-17=-193911417, 6-7=-171611318,
7-8=-1115/909
BOT CHORD
1 -11 =-496/703, 10-11=-1748/1117,
9-10=-1238/1071, 8-9=-1223/1050
WEBS
2-1 0=-1 10/588, 4-10=-43/263,
9-12=-287/722, 6-12=-340/547,
'WEBS
12-1 0=-1 10/588, 4-10=-43/263,
9-12=-287/722, 6-12=-340/547,
5-12=-2211/2768, 2-11=-1223/1541,
' 7-12=-1896/2421, 8-12=-2535/2951
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) 100.01b AC unit load placed on the top chord,
14-0-0 from left end, supported at two points, 2-0-0
apart.
3) All plates are MT20 plates unless otherwise
indicated.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5)' This truss has been designed foe a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Bottom chord live load (30.0 psf) and additional
bottom chord dead load (0.0 psf) applied only to room.
9-10
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 776 lb uplift at
joint 8 and 594 lb uplift at joint 11.
9) ATTIC SPACE SHOWN IS DESIGNED AS
UNINHABITABLE.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
A0117208
72005
A09
Monopitch
2
1
Job Reference (optional
Al ROW I cusses, 1-ort Fierce, rL 34u4b, cesignLaiiruss.com
2-1-8
2-1-8
3x8 1111
u�
0
9
3x8 = 3x6 11
2-1-8
o. i<va is ". 1. ..1ma, an.. �n.. �.�oy ., ..... ...«. �.. .. y..
I D:nKMLCG99vHyLG9D5?YIAEyzKd3P-aU_T6gt4TH4pYcnZRNGTROYIDiga4w01BtoAiBzKG WJ
5.00 12 5
Ll'��
x6
4x6 �q
3
8 7 6
4x6 = 6x6 =
2x4 11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc)
I/defl
L/d
TCLL 30.0
Plate Grip DOL
1.25
TC 0.88
Vert(LL) 0.16
6-8
>999
360
TCDL 15.0
Lumber DOL
1.25
BC 0.91
Vert(CT) -0.33
6-8
>699
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.92
Horz(CT) -0.03
6
n/a
n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MS
LUMBER -
TOP CHORD 2x6 SP 240OF 2.0E `Except'
T1: 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 4-8-11 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 4-9-5 oc bracing.
WEBS
1 Row at midpt 5-6, 4-6
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
9 = 1295/0-8-0 (min.0-1-8)
6 = 1031/Mechanical
Max Horz
9 = 789(LC 12)
Max Uplift
9 =-632(LC 12)
6 =-839(LC 12)
Max Grav
9 = 1295(LC 1)
6 = 1031(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-1175/487, 2-3=-1473/963,
3-4=-1217/992, 4-5=-292/126,
5-6=-4211709
BOT CHORD
1-9=-560/1224, 8-9=-1811/1295,
7-8=-1811/1295,6-7=-1811/1295
WEBS
2-9=-875/1230, 4-8=0/374,
4-6=-1380/1932
NOTES-
1) Wind: ASCE 7-11
Vasd=139mph; TCI
Cat. 11; Exp D; Encl,
and C-C Exterior(2)
for members and fc
shown; Lumber DO
2) This truss has be
chord live load non(
loads.
3)' This truss has I
20.Opsf on the bott(
rectangle 3-6-0 tall
bottom chord and a
4) Refer to girders;
5) Provide mechani
to bearing plate car
joint 9 and 839 lb ul
LOAD CASE(S)
Standard
I; Vult=180mph (3-second gust)
)L=5.Opsf; BCDL=5.Opsf, h=39ft;
GCpi=0.18; MWFRS (envelope)
zone; cantilever left exposed ;C-C
�ces & MWFRS for reactions
1.60 plate grip DOL=1.60
en designed for a 10.0 psf bottom
oncurrent with any other live
m designed for a live load of
chord in all areas where a
2-0-0 wide will fit between the
other members.
r truss to truss connections.
connection (by others) of truss
le of withstanding 632 lb uplift at
t at joint 6.
Dead Load Defl. = 3/16 in
PLATES GRIP
MT20 244/190
Weight: 141 lb FT = 10%
Job
Truss
Truss Type
city
Ply
72005
A09A
ATTIC
1
1
A0117209
Job Reference (optional)
I'll -oo I russes, ro,L Merce, rL J9946, uesignLa-Ih
8.120 s Nov 12 2017 MiTek Industries, Inc. Thu
5.00 12 �— u
11 10 9 8
4x4 = 3x8 II 7x6 = 2x4 II 10x10 =
21-3-2
3 09:15:23 2018 Page 1
Dead Load Defl. = 3/16 in
Plate Offsets (X,Y)—
[1:0-2-3,Edgel,[2:0-2-12 0-4-4][3:0-5-0 Edge]
[5:0-2-1 0-0-0] [10:0-3-0 0-4-81 [11.0-4-9 0-1-81 [12.0-2-8 0-0-121
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc)
I/defl
Ud
PLATES
GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC
0.92
Vert(LL) 0.47 10-11
>480
360
MT20
244/190
TCDL 15.0
Lumber DOL 1.25
BC
0.97
Vert(CT) -0.48 9-10
>475
240
MT20HS
187/143
BCLL 0.0
Rep Stress Incr YES
WB
0.88
Horz(CT) -0.02 8
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Attic -0.14 9-10
704
360
Weight: 168 Ib
FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 `Except`
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
pudins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS
1 Row at midpt
7-8, 5-12, 8-12
JOINTS
1 Brace at Jt(s): 12
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
8 =
1093/Mechanical
11 =
1333/0-8-0 (min. 0-1-9)
Max Horz
11 =
789(LC 12)
Max Uplift
8 =
-776(LC 12)
11 =
-594(LC 12)
Max Grav
8 =
1194(LC 2)
11 =
1333(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-589/349, 2-3=-1342/451,
3-4=-1165/459, 4-16=-1057/579,
5-16=-954/600, 5-17=-1965/1345,
6-17=-1939/1417, 6-7=-1716/1318,
7-8=-1115/909
BOT CHORD
1 -11 =-496/703, 10-11=-1748/1117,
9-10=-1238/1071,8-9=-1223/1050
WEBS
2-1 0=-1 10/588, 4-10=-43/263,
9-12=-287/722, 6-12=-340/547,
WEBS
'2-1 0=-1 10/588, 4-10=-43/263,
9-12=-287/722, 6-12=-340l547,
5-12=-2211/2768, 2-11=-1223/1541,
1 7-12=-1896/2421, 8-12=-2535/2951
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf, BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) 100.01b AC unit load placed on the top chord,
14-0-0 from left end, supported at two points, 2-0-0
apart.
3) All plates are MT20 plates unless otherwise
indicated.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members:
6) Bottom chord live load (30.0 psf) and additional
bottom chord dead load (0.0 psf) applied only to room.
9-10
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 776 lb uplift at
joint 8 and 594 lb uplift at joint 11.
9) ATTIC SPACE SHOWN IS DESIGNED AS
UNINHABITABLE.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
A0117210
72005
A10
Monopitch 1
1
1
r
Job Reference (optional)
Al Floor Trusses, rOrr coerce, rL 34V40, Oe519f1(C0 IU U55.00111
2-1-8
3x8 11
0
9
3x8 = 3x6 II
2-1-8
1-M .
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-2gYsK0ujEaCgAmMI?4ni-c5wz60ppNGrQXXkEazKGWI
3x6' 11
5.00 F12 5
6x6
4x6 4 4
3 c&
W3
$2.. — .....'......_...
LU
8 ?
2x4 114x6 =
6
6x6 =
Dead Load Deff. = 3/16 in
Plate Offsets (X Y)- [4.0-3-0 0-4-0] [5.0-4-4 0-0-0] [6:0-3-0 0-4-plate Offsets Y)- -3 0-4 0-0 [6:0-3 0-4-8]f9:0-4-8 0-1-81-4-8 0-1
81
LOADING (psf)
SPACING- 2-0-0
CST.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.88
Vert(LL) 0.16 6-8 >999 360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.91
Vert(CT) -0.33 6-8 >699 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.92
Horz(CT) -0.03 6 n/a n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MS
Weight: 141 Ib FT = 10%
LUMBER -
TOP CHORD 2x6 SP 2400F 2.0E "Except`
T1: 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2
BRACING- -
TOP CHORD
Structural wood sheathing directly applied or 4-8-11 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 4-9-5 oc bracing.
WEBS
1 Row at midpt 5-6, 4-6
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation Quide.
REACTIONS. (lb/size)
9 =
1295/0-8-0 (min. 0-1-8)
6 =
1031/Mechanical
Max Horz
9 =
789(LC 12)
Max Uplift
9 =
-632(LC 12)
6 =
-839(LC 12)
Max Grav
9 =
1295(LC 1)
6 =
1031(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-1175/487, 2-3=-1473/963,
3-4=-1217/992, 4-5=-292/126,
5-6=-4211709
BOT CHORD
1-9=-560/1224, 8-9=-1811/1295,
7-8=-1811/1295, 6-7=-1811/1295
WEBS
2-9=-875/1230, 4-8=0/374,
4-6=-1380/1932
NOTES-
1) Wind: ASCE 7-1
Vasd=139mph; TC
Cat. 11; Exp D; Encl
and C-C Exterior(2
for members and f(
shown; Lumber DC
2) This truss has b
chord live load non
loads.
3) ' This truss has
20.Opsf on the bott
rectangle 3-6-0 tall
bottom chord and r
4) Refer to girder(s
5) Provide mechan
to bearing plate ca
joint 9 and 839 lb L
LOAD CASE(S)
Standard
Vult=180mph (3-second gust)
L=S.Opsf; BCDL=5.Opsf, h=39ft;
GCpi=0.18; MWFRS (envelope)
gone; cantilever left exposed ;C-C
:es & MWFRS for reactions
=1.60 plate grip DOL=1.60
:n designed for a 10.0 psf bottom
mcurrent with any other live
:n designed for a live load of
chord in all areas where a
2-0-0 wide will fit between the
other members.
r truss to truss connections.
connection (by others) of truss
le of withstanding 632 lb uplift at
t at joint 6.
Job
Truss
Truss Type
Qty
Ply
72005
A10A
ATTIC
1
1
A0117211
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com 8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:15:24 2018 Page 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-Wt6EXLuL?uKXnwxxZolxWpd4CWL6YrD fBHHmlzKGWH
21-3-2 — 4
0-b-6 10.1-6 18-4-14 20-10-0�
s-3-s 2-5-2 as2
4x6
5.00 12 2x4 II 7
111 10 9 8
4x4 = 3x8 11 7x6 =
2-1-8
2x4 II 10x10=
21-3-2
co
Dead Load Deff. = 3/16 in
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
L/d
PLATES
GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.92
Vert(LL)
0.47
10-11
>480
360
MT20
244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.97
Vert(CT)
-0.48
9-10
>475
240
MT20HS
187/143
BCLL 0.0 *
Rep Stress Incr
YES
WB 0.88
Horz(CT)
-0.02
8
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Attic
-0.14
9-10
704
360
Weight: 168 Ib
FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS
1 Row at midpt
7-8, 5-12, 8-12
JOINTS
1 Brace at Jt(s): 12
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
8 =
1093/Mechanical
11 =
1333/0-8-0 (min. 0-1-9)
Max Horz
11 =
789(LC 12)
Max Uplift
8 =
-776(LC 12)
11 =
-594(LC 12)
Max Grav
8 =
1194(LC 2)
11 =
1333(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-589/349, 2-3=-1342/451,
3-4=-1165/459, 4-16=-1057/579,
5-16=-954/600, 5-17=1965/1345,
6-17=-1939/1417, 6-7=-1716/1318,
7-8=-1115/909
BOT CHORD
1-11=-496/703, 10-11=-1748/1117,
9-10=-1238/1071,8-9=-1223/1050
WEBS
2-10=-110/588, 4-10=-43/263,
9-12=-287/722, 6-12=-340/547,
WEBS
2-1 0=-1 10/588, 4-10=-43/263,
9-12=-287/722, 6-12=-340/547,
5-12=-2211/2768, 2-11=-1223/1541,
7-12=-1896/2421, 8-12=-2535/2951
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf, BCDL=5.Opsf; h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;C-C
j for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
j 2) 100.01b AC unit load placed on the top chord,
14-0-0 from left end, supported at two points, 2-0-0
apart.
3) All plates are MT20 plates unless otherwise
indicated.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) * This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Bottom chord live load (30.0 psf) and additional
bottom chord dead load (0.0 psf) applied only to room.
9-10
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 776 lb uplift at
joint 8 and 594 lb uplift at joint 11.
9) ATTIC SPACE SHOWN IS DESIGNED AS
UNINHABITABLE.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
AO117212
72005
A11
Half Hip
1
1
r
Job Reference (optional)
Al Moot irusses, t-onvierce, r-L -Auqu, oesrgn(Na-r[russ.wrn — .� 1........—...... ..—
I D:nKMLCG99vHyLG9D5?YIAEyzKd3P-_3gclhvzmCSOP3W87VpA31 AIXvmOH KZ8trOgJTzKGWG
0-02-1-8 10-4-1 1 18-10-0 21-3-2
0- 2-1-8 8-2-9 8-5-15 2-5-2
3x8 = 2x4 II 46 = 7x8 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc)
I/defl
L/d
TCLL
30.0
Plate Grip DOL
1.25
TC 0.75
Vert(LL) -0.14
7-9
>999
360
TCDL
15.0
Lumber DOL
1.25
BC 0.67
Vert(CT) -0.32
7-9
>714
240
BCLL
0.0
Rep Stress Incr
YES
WB 0.74
Horz(CT) -0.03
7
n/a
n/a
BCDL
10.0
Code FBC2017frPI2014
Matrix -MS
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 4-8-7 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 5-3-6 oc bracing.
WEBS
1 Row at midpt 4-7
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
7 =
1031/Mechanical
10 =
1295/0-8-0 (min.0-1-8)
Max Horz
10 =
706(LC 12)
Max Uplift
7 =
-731(LC 12)
10 =
-664(LC 12)
Max Grav
7 =
1031(LC 1)
10 =
1295(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-1086/424, 2-3=-1424/986,
3-4=-1169/1014, 4-5=-323/25
BOT CHORD
1 -1 0=-550/1164, 9-1 0=-1 669/1223,
8-9=-1669/1223, 7-8=-1669/1223
WEBS
2-10=-982/1452, 4-9=0/381, 5-7=-544/871,
4-7=-1166/1545
NOTES-
1) Wind: ASCE 7-1
Vasd=139mph; TC
Cat. II; Exp D; End
and C-C Exterior(2
for members and f(
shown; Lumber DC
2) Provide adequal
ponding.
3) This truss has bi
chord live load non
loads.
4) ` This truss has
20.Opsf on the bott
rectangle 3-6-0 tall
bottom chord and
5) Refer to girder(s
6) Provide mechan
to bearing plate cal
joint 7 and 664 lb u
LOAD CASE(S)
Standard
Vult=180mph (3-second gust)
=5.Opsf; BCDL=S.Opsf, h=39ft;
GCpi=0.18; MWFRS (envelope)
!one; cantilever left exposed ;C-C
:es & MWFRS for reactions
=1.60 plate grip DOL=1.60
drainage to prevent water
designed for a 10.0 psf bottom
-urrent with any other live
;n designed for a live load of
chord in all areas where a
2-M wide will fit between the
other members.
r truss to truss connections.
connection (by others) of truss
le of withstanding 731 lb uplift at
t at joint 10.
PLATES
MT20
Dead Load Defl. = 3/16 in
GRIP
2441190
Weight: 150 Ib FT = 10%
Job
Truss
Truss Type
Qty
ply
72005
A11A
ATTIC
1
I
1
A0117213
Job Reference (optional)
M Ruui i n usses, run rieice, rL r+awo, 0esignLa itruss.cwm 8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:15:26 2018 Page 1
ID:nKMLCG99vHyLG9D57YIAEyzKd3P-SFDy1 wbXVaF1 DSKgDKPbEjQaJ1!n0lnH6VmOrvzKGWF
O-Q-0 10-1-6 18-4-14 1810-0213-2
oos 1o•1s 838 osz 2-5-2
5-On
4x6 = 6x6 =
6 7 8
4x4 = 3x8 II 7x6 = 2x4 II 10x10 =
21-3-2
Dead Load Deb. = 3/16 in
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL.
in (loc)
I/deft
Ud
PLATES
GRIP
TCLL
30.0
Plate Grip DOL
1.25
TC 0.92
Vert(LL)
0.46 11-12
>500
360
MT20
244/190
TCDL
15.0
Lumber DOL
1.25
BC 0.96
Vert(CT)
-0.47 10-11
>486
240
MT20HS
187/143
BCLL
0.0
Rep Stress Incr
YES
WB 0.87
Horz(CT)
-0.02 9
n/a
n/a
BCDL
10.0
Code FBC2017/TPI2014
Matrix -MS
Attic
-0.14 10-11
717
360
Weight: 165 Ib
FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 `Except`
W4: 2x4 SP No.2, W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS
1 Row at midpt 8-9, 9-13
JOINTS
1 Brace at Jt(s): 13
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide. I]
REACTIONS. (lb/size)
9 =
1093/Mechanical
12 =
1333/0-8-0 (min. 0-1-9)
Max Horz
12 =
706(LC 12)
Max Uplift
9 =
-669(LC 12)
12 =
-627(LC 12)
Max Grav
9 =
1194(LC 2)
12 =
1333(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-588/354, 2-3=-1346/576,
3-4=-1168/584, 4-17=-1058/705,
5-17=-955/725, 5-18=-1792/1276,
6-18=-1 766/1348, 6-7=-1 356/1078,
7-8=-1537/1207, 8-9=-1 176/951
BOT CHORD
1-12=-504/698, 11-12=-1623/1071,
10-11 =-1 222/1074, 9-1 0=-1 207/1052
WEBS
2-11=-70/570, 4-11=-37/266,
10-13=-266/715, 6-13=-735/1043,
5-13=-2187/2722, 2-12=-1 230/1602,
'WEBS
2-11=-70/570, 4-11=-37/266,
10-13=-266/715, 6-13=-735/1043,
5-13=-2187/2722, 2-12=-1230/1602,
8-13=-1612/2052, 9-13=-2541/2914
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=S.Opsf; BCDL=5.Opsf, h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) 100.01b AC unit load placed on the top chord,
14-0-0 from left end, supported at two points, 2-0-0
apart.
3) Provide adequate drainage to prevent water
ponding.
4) All plates are MT20 plates unless otherwise
indicated.
5) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
6) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
7) Bottom chord live load (30.0 psf) and additional
bottom chord dead load (0.0 psf) applied only to room.
10-11
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 669 lb uplift at
joint 9 and 627 lb uplift at joint 12.
10) ATTIC SPACE SHOWN IS DESIGNED AS
UNINHABITABLE.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
A0117214
72005
Al2
Half Hip
1
1
Job Reference (optional)
Al KOor I cusses, tort tierce, M 34u4b, aesignLa-irrus5.com
o. icy a -mow � c cu � i rvu�cn inuuauica,-n- I— way u..o. ...�.. �.. ...oy..,
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-SFD_r1wbXVaF1 D5KgDKPbEjSMJ740pdH6VmOrvzKGWF
16-10-0 1 21-3-2
5x8 -
5.00 12 5
3x8 11
5x6 � 1 4 ,
2x4 11
Dead Load Deft. = 3116 in
6
y 3 wl
4x16 II
2 NQ
0 10 9 8 14 15 7
3x8 =
3x4 = 4x6 — 6x6 =
1-9-82T1r8 10-4-1 20-11-10 21r$ 2
1-9 80-4-0 B-2-9 1 10-7-9 0- -8
Plate Offsets (X Y)— [2.0-0-1 1-11-14] [7:0-3-0 0-4-8]
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP
TCLL 30.0 Plate Grip DOL 1.25 TC 0.81 Vert(LL) -0.19 7-9 >999 360 MT20 244/190
TCDL 15.0 Lumber DOL 1.25 BC 0.62 Vert(CT) -0.37 7-9 >620 240
BCLL 0.0 ' Rep Stress Incr YES WB 0.63 Horz(CT) -0.02 7 n/a n/a
BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 146 Ib FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP N0.2
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 4-8-2 oc
pudins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 5-6-10 oc bracing.
WEBS
1 Row at midpt 5-9, 5-7
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
7 = 1031/Mechanical
10 = 1295/0-8-0 (min.0-1-8)
Max Horz
10 = 631(LC 12)
Max Uplift
7 =-647(LC 12)
10 =-683(LC 12)
Max Grav
7 = 1031(LC 1)
10 = 1295(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-1035/420, 2-3=-1398/1028,
3-4=-1220/1056, 4-5=-1344/1535
BOT CHORD
1-10=-573/1131, 9-1 0=-1 574/1173,
8-9=-661/467, 8-14=-661/467,
14-15=-661/467, 7-15=-661/467
WEBS
2-10=-1044/1571, 4-9=-626/1177,
5-9=-1357/1072, 5-7=-890/1282
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf, BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl .1, GCpi=0.18; MWFRS (envelope)
and C-C Extedor(2)lzone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water
ponding.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
4)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
10.Opsf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 647 lb uplift at
joint 7 and 683 lb upi ift at joint 10.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
72005
Al2A
ATTIC
1
1
A0117215
Job Reference (optional)
r. rwui i usses, rui r riciuc, FL .rr�o, uesiynud 11rU55.wrn 8.12u s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:15:27 2018 Page 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-wSn MANxDHpj6eNfW Ewse8SFbljN71DtRL9VxNMzKGWE
0 Q 0 10-1� 16-10-0 18� 14 21-3-2 ' A
0 0� 10-1� 6 8 10 1-6-14 2-10 4
5x6 = 3x8 11 6x6 =
Dead Load Deft. = 3/16 in
4x4 = 3x8 11 7x6 = 2x4 11 8x8 =
Plate Offsets (X,Y)—
[1:0-2-3,Edgel, [2:0-2-12,0-4-4]
[3:0-5-0 Edge] [5:0-2-1 0-0-0] [9:Edge 0-4-12] [1.1.0-3-0 0-4-8] [12.04-10 0-1-71 [13.0-5-0 0-2-9)
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc)
I/deft
L/d
PLATES
GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.93
Vert(LL) 0.45 11-12
>501
360
MT20
2441190
TCDL 15.0
Lumber DOL 1.25
BC 0.96
Vert(CT) -0.47 10-11
>486
240
MT20HS
187/143
BCLL 0.0
Rep Stress Incr YES
WB 0.82
Horz(CT) -0.02 9
n/a
n/a
BCDL 10.0
Code FBC2017[TP12014
Matrix -MS
Attic -0.14 10-11
719
360
Weight: 164 Ib
FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS
1 Row at midpt
8-9, 5-13, 9-13
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
9 =
1093/Mechanical
12 =
1333/0-8-0 (min. 0-1-9)
Max Horz
12 =
631(LC 12)
Max Uplift
9 =
-584(LC 12)
12 =
-645(LC 12)
Max Grav
9 =
1194(LC 2)
12 =
1333(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-592/360, 2-3=-1348/667,
3-4=-1171/674, 4-17=-1061/800,
5-17=-958/821, 5-18=-1716/1284,
6-18=-1690/1336, 6-7=-2146/1698,
7-8=-2115/1672,8-9=-1081/884
BOT CHORD
1-12=-514/698, 11-12=-1515/1032,
10-11 =-1 188/1076, 9-1 0=-1 17811066
WEBS
2-11=46/570, 4-11=40/269,
10-13=-267/714, 7-13=-412/567,
5-13=-2267/2744, 2-12=-1228/1636,
8-13=-1899/2403,9-13=-2499/2758,
WEBS
2-11=-46/570, 4-11=-40/269,
10-13=-267014, 7-13=-412/567,
5-13=-2267/2744, 2-12=-1228/1636,
8-13=-1899/2403, 9-13=-2499/2758,
6-13=-617/797
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf, h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) 100.0Ib AC unit load placed on the top chord,
14-0-0 from left end, supported at two points, 2-0-0
apart.
3) Provide adequate drainage to prevent water
ponding.
4) All plates are MT20 plates unless otherwise
indicated.
5) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
6) * This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-M wide will fit between the
bottom chord and any other members.
7) Bottom chord live load (30.0 psf) and additional
bottom chord dead load (0.0 psf) applied only to room.
10-11
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 584 lb uplift at
joint 9 and 645 lb uplift at joint 12.
10) ATTIC SPACE SHOWN IS DESIGNED AS
UNINHABITABLE.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Oty
Ply
A0117216
72005
A13
Half Hip
I
1
1
>•
Job Reference (optional)
Al KDOr i fusses, rorr Fierce, rL 34V40, ❑eslgn((La I lrussdJVrn
0-0-0 2-1-8
ID:nKMLCG99vHyt- 5?YIAEyzK, 31-ZnMANxDHpj6eNfWEwseBSFcTjTgIJeRL9VxNMzKGWE
14-10-0 21-3-2
4-5-15 & 2
5x8
5.00 12 5
3x6 11
5x6
3 I
2x4 11
Dead Load Defl. = 3116 in
6
4x12 II
2
VV/
N
n 1
o
,
10
9 8 14 15
7
3x4 = 46 =
6x6 =
3x8 =
1-9-82T1r8
10-4-1
20-11-10
21,- -2
1-9-80-4-0
8-2-9
1 10-7-9
0-3-8
Plate Offsets X Y -- 2:0-0-1,1-11-14 , :0-3-0,0-4-8
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft
L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.85
Vert(LL) -0.17 7-9 >999
360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.59
Vert(CT) -0.33 7-9 >686
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.39
Horz(CT) -0.02 7 n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 142 Ib FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
NOTES-
BOTCHORD 2x6 SP No.2
`Except'
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
WEBS 2x4 SP No.3
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
W1: 2x6 SP No.2
Cat. II; Exp D; Encl 1, GCpi=0.18; MWFRS (envelope)
BRACING-
and C-C Exterior(2)Izone; cantilever left exposed ;C-C
TOP CHORD
for members and forces & MWFRS for reactions
Structural wood sheathing directly applied or 4-7-10 oc
shown; Lumber DOL=1.60 plate grip DOL=1.60
purlins, except end verticals.
2) Provide adequate drainage to prevent water
BOT CHORD
ponding. +
Rigid ceiling directly applied or 5-9-0 oc bracing.
3) This truss has been designed for a 10.0 psf bottom
EBS
1VRow
chord live load nonconcurrent with any other live
at midpt 5-9, 5-7
loads.
MiTek recommends that Stabilizers and required
4) This truss has been designed for a live load of
cross bracing be installed during truss erection, in
20.Opsf on the bottom chord in all areas where a
accordance with Stabilizer Installation guide.
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
REACTIONS. (lb/size)
10.0psf.
7 = 1031/Mechanical
5) Refer to girder(s) for truss to truss connections.
10 = 1295/0-8-0 (min. 0-1-8)
6) Provide mechanical connection (by others) of truss
Max Horz
to bearing plate capable of withstanding 627 lb uplift at
10 = 556(LC 12)
joint 7 and 691 lb uplift at joint 10.
Max Uplift "
7 =-627(LC 9)
10 =-691(LC 12)
LOAD CASE(S)
Max Grav
Standard
7 = 1031(LC 1)
10 = 1295(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-1004/438, 2-3=-1382/1074,
3-4=-1203/1102, 4-5=-1281/1503,
6-7=-264/357
BOT CHORD
1-10=-607/11 11, 9-10=-1489/1130,
8-9=-902/673, 8-14=-902/673,
14-15=-902/673, 7-15=-902/673
WEBS
2-1 0=-1 082/1644, 4-9=-519/994,
5-9=-1012/848, 5-7=-929/1263
Job
Truss
Truss Type
City
Ply
72005
A13A
ATTIC
1
1
A0117217
Job Reference (optional)
1�001 IIUDDCJ, VU1L MCI UU, rL J ZF40, UCSlyn(Wd l iFU55.COM 1
6.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:15:28 2018
Dead Load Defl. =114 in
3x8 11 7x6 = 3x8 11 8x8 =
4x4 =
Plate Offsets (X,Y)— [1:0-1 -1 5,Edge], [2:0-2-12,0-4-4], [3:0=5-0,Edge],
f13:0-1-9,0-0-12j j14:0-5-9 0-1-11]
[5:Edge,0-6-3], [7:0-4-10,0-1-8], [8:0-3-0,0-4-0], [9:Edge,0-4-8], [11:0-3-0,0-5-0], [12:0-4-9,0-1-5],
1
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/deft
L/d
PLATES
GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.88
Vert(LL)
0.54 11-12
>423
360
MT20
244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.82
Vert(CT)
-0.53 11-12
>431
240
MT20HS
187/143
BCLL 0.0 '
Rep Stress Incr YES
WB 0.78
Horz(CT)
-0.02 9
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Attic
-0.15 10-11
676
360
Weight: 159 Ib
FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2 *Except*
T3: 2x6 SP 240OF 2.0E
BOT CHORD 2x6 SP No.2 `Except`
82: 2x6 SP 240OF 2.0E
WEBS 2x4 SP No.3 `Except'
W4: 2x4 SP No.2, W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
pudins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 3-10-4 oc bracing.
WEBS
1 Row at midpt 5-14, 9-14
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
9 =
1093/Mechanical
12 =
1333/0-8-0 (min. 0-1-9)
Max Horz
12 =
556(LC 12)
Max Uplift
9 =
-565(LC 9)
12 =
-653(LC 12)
Max Grav
9 =
1194(LC 2)
12 =
1333(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-666/412, 2-3=-1301/687,
3-4=-1132/695, 4-18=-1059/877,
5-18=-956/897, 5-6=-1820/1423,
6-7=-1861/1472, 7-8=-2080/1626,
8-9=-869l723
BOT CHORD
1-12=-576/741, 11-12=-1458/1037,
10-1 1=-1 101/1044,9-10=-1074/1009
WEBS
2-1 1=-110/525,4-11=-143/403,
10-14=-522/901, 7-14=-1127/1414,
! WEBS
i 2-11=-110/525, 4-11=-143/403,
10-14=-522/901, 7-14=-1127/1414,
j 5-13=-2459/2990, 13-14=-2435/2962,
2-12=-1098/1515, 8-14=-1673/2140,
9-14=-2465/2625
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) 100.01b AC unit load placed on the top chord,
14-0-0 from left end, supported at two points, 2-0-0
i apart.
3) Provide adequate drainage to prevent water
ponding.
4) All plates are MT20 plates unless otherwise
indicated.
5) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
6)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
7) Bottom chord live load (30.0 psf) and additional
bottom chord dead load (0.0 psf) applied only to room.
10-11
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 565 lb uplift at
joint 9 and 653 lb uplift at joint 12.
10) ATTIC SPACE SHOWN IS DESIGNED AS
UNINHABITABLE.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
A0117218
72005
A14
Half Hip
1
1
a
Job Reference (optional)
Al Hoot I russes, fort Tierce, rL 64&4b, aesignLarrruss.com a "U. �— -< " ������u—,'.— .— .
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-tgv7a3yTpQzquhpvM Lu6DtLyaX9W DAvkoS_2SEzKG WC
0- -0 2-1-8 10-4-1 12-10-0 21-3-2
0- -6 2-1-8 8-2-9 2-5-15 8-5-2
5x8 a
4x6 11
Dead Load Defl. = 1/8 in
3x8 =
3x4 = 4xb = 6x6 =
2r1r8
10-4-1
20-11-10
1-9-8 0�10
8-2-9
10-7-9
0-3-8
Plate Offsets (X Y)_- [2.0-0-1 1-11-14] [5:Edge 0-3-81 [6:0-3-0 0-4-81
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl
Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.88
Vert(LL) -0.13 6-8 >999
360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.57
Vert(CT) -0.29 6-8 >778
240
BCLL 0.0 "
Rep Stress Incr YES
WB 0.53
Horz(CT) -0.02 6 n/a
n/a
BCDL 10.0
Code FBC20177TP12014
Matrix -MS
Weight: 140 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
NOTES-
BOT CHORD 2x6 SP No.2
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
WEBS S"Except"
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Wl: 2xx6 SP No.2
W1SP
Cat. 11; Exp D; Encl �, GCpi=0.18; MWFRS (envelope)
BRACING-
and C-C Extedor(2)Izone; cantilever left exposed ;C-C
TOP CHORD
for members and forces & MWFRS for reactionsshown;
Structural woad sheathing directly applied or 2-2-0 oc
Lumber DOL=1.60 plate grip DOL=1.60
purlins, except end verticals.
2) Provide adequate drainage to prevent water
BOT CHORD
ponding.
Rigid ceiling directly applied or 5-10-9 oc bracing.
3) This truss has been designed for a 10.0 psf bottom
WEBS
chord live load nonconcurrent with any other live
1 Row at midpt 4-6
loads.
MiTek recommends that Stabilizers and required
4) " This truss has been designed for a live load of
cross bracing be installed during truss erection, in
20.Opsf on the bottoI rn chord in all areas where a
accordance with Stabilizer Installation quide. I
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
REACTIONS. (lb/size)
10.0psf.
6 = 1031/Mechanical
5) Refer to girder(s) Ifor truss to truss connections.
9 = 1295/0-8-0 (min. 0-1-8)
6) Provide mechanical connection (by others) of truss
Max Horz
to bearing plate capable of withstanding 638 lb uplift at
9 = 482(LC 12)
joint 6 and 688 lb uplift at joint 9.
Max Uplift
6 =-638(LC 9)
9 =-688(LC 12)
LOAD CASE(S)
Max Grav
Standard
6 = 1031(LC 1)
9 = 1295(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-991/476, 2-3=-1373/1150,
3-4=-1207/1466, 5-6=-349/472
BOT CHORD
1-9=-648/1101, 8-9=-1412/1101,
7-8=-1 131/898, 7-13=-1 131/898,
13-14=-1131/898, 6-14=-1131/898
WEBS
2-9=-1096/1672, 3-8=-393l791,
4-8=-678/619, 4-6=-1036/1320
I
Job
Truss
Truss Type
Qty
Ply
72005
A14A
ATTIC
1
1
A0117219
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com
8! 120 s Nov 12 2017 MiTek Industries, Inc. Thu
4x4 = 3x8 11 7x6 = 3x8 11 7x6 =
3 09:15:29 2018 Pagel
(6i4D31 koS-2SEzKGWC
J-
Dead Load Deft. = 3/16 In
1-5-a 171 rti
10-1-6
18-4-14
20-11-10 21-$-2
1-9-8 04-0
7-11-14
8-3-8
2 6 12 0-3-8
Plate Offsets (X,Y)—
[2:0-2-12,0-4-41,[4:Edge,0-6-31 [5:0-3-14 0-2-151 [6:04-9 0-1-81
[7:0-3-0 0-3-12] [8:0-3-0 0-4-8] [10.0-3-0 04-81 N 1.04-10 0-1-81
[13.0-3-12 0-1-121
i
LOADING (psf)
TCLL 30.0
SPACING- 2-0-0
Plate Grip DOL 1.25
CSI.
TC 0.77
DEFL. in (loc)
Vert(LL) 0.43 10-11
I/deft
>527
L/d
360
PLATES
MT20
GRIP
244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.72
Vert(CT) -0.42 10-11
>537
240
BCLL 0.0 *
Rep Stress Incr YES
WB 0.97
Horz(CT) -0.02 8
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Attic -0.13 9-10
806
360
Weight: 158 lb
FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2 *Except*
T2: 2x6 SP 240OF 2.0E
BOT CHORD 2x6 SP No.2 *Except*
B2: 2x6 SP 240OF 2.0E
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-3-2 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 4-9-12 oc bracing.
WEBS
1 Row at midpt 4-13, 8-13
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
8 =
1093/Mechanical
11 =
1333/0-8-0 (min. 0-1-9)
Max Horz
11 =
482(LC 12)
Max Uplift
8 =
-576(LC 9)
11 =
-651(LC 12)
Max Grav
8 =
1194(LC 2)
11 =
1333(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-583/338, 2-3=-1378/850,
3-4=-1136/1026, 4-5=-885/593,
5-17=-933/649, 6-17=-933/649,
6-7=-1179/832, 7-8=-677/558
BOT CHORD
1 -11 =-447/645, 10-11=-1212/894,
9-10=-1148/1133,8-9=-1120/1095
WEBS
2-10=0/655, 3-10=-148/404,
9-13=-488/883, 6-13=-1161/1389,
4-12=-1683/2091, 12-13=-1676/2081,
2-11=-1079/1526, 7-13=-852/1209,
WEBS
2-10=0/655, 3-10=-148/404,
9-13=-488/883, 6-13=-1161/1389,
4-12=-1683/2091, 12-13=-1676/2081,
2-11 =l 079/1526, 7-13=-852/1209,
8-13=-2361 /2416
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf, h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) 100.01b AC unit load placed on the top chord,
14-0-0 from left end, supported at two points, 2-0-0
apart.
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) * This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Bottom chord live load (30.0 psf) and additional
bottom chord dead load (0.0 psf) applied only to room.
9-10
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 576 lb uplift at
joint 8 and 651 lb uplift at joint 11.
9) ATTIC SPACE SHOWN IS DESIGNED AS
UNINHABITABLE.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
A0117220
72005
A15
Common
L
2
1
�
Job Reference (optional)
Al Rbof Trusses, Fort Pierce, FL 34946, design@altruss.com
5.00 12
3x8 = 4xl6 11
2x4 ��
6.i20 s Nov i2 2017 Mi Iek industries, Inc. Thu May a Va: IO:OV 20 io raye i
I D:nKMLCG99vHyLG9D5?YIAEyzKd3P-L1 TVoPz6ak5gWrO5v2PLm4tEMwVJyaCti 6kb_gzKGWB
5x6 =
6x8 =
4x6
5
20-11-10
4x4 i1
6
7
6x6 =
Dead Load Defl. = 1/16 in
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
L/d
PLATES GRIP
TOLL 30.0
Plate Grip DOL
1.25
TC 0.43
Vert(LL)
0.11
7-8
>999
360
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.54
Vert(CT)
-0.13
7-8
>999
240
BC LL 0.0 '
Rep Stress Incr
YES
WB 0.72
Horz(CT)
0.02
7
n/a
n/a
BC DL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 138 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP 240OF 2.OE *Except*
T2: 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1,W5: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
pudins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 6-2-8 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
9 =
1291/0-8-0 (min. 0-1-8)
7 =
1026/Mechanical
Max Horz
9 =
223(LC 12)
Max Uplift
9 =
-717(LC 12)
7 =
-553(LC 13)
Max Grav
9 =
1291(LC 1)
7 =
1026(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-1004/811, 2-3=-1371/1490,
3-4=-1 097/1300, 4-5=-1 141/1344,
5-6=-338/394, 6-7=-324/465
BOT CHORD
1-9=-980/1103, 8-9=-1133/1103,
7-8=-1240/1149
WEBS
3-8=-223/402, 4-8=-374/411,
2-9=-1056/1718, 5-8=-274/542,
5-7=-1097/1228
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl.� GCpi=0.18; MWFRS (envelope)
and C-C Extedor(2)lzone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom
chord live load nonc'oncurrent with any other live
loads.
4) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall 6y 2-0-0 wide will fit between the
bottom chord and ar?y other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss
to bearing plate cap ble of withstanding 717 lb uplift at
joint 9 and 553 lb up�ift at joint 7.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
72005
A16
Hip
2
1
A0117221
Job Reference (optional)
1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com 8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:15:31 2018 Page 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-pD1 t?I_kL2DX7-zlTmwal IQGQKr5hOWOGmT9W°p
7zKG WA
0-10-6-0 55 21-3_2
0-0-0 10-6-0 2-0 5&5-5-13
5x6 � 5x6 =
axo — 4x16 II 2x4 II 4x6 = 3x4 = 6x6 =
21-3-2
1-9-8 1 10-&0 13-1-0 20-9-10 20- - 0
1-9-8 -4- 874-8 2-7-0 7-8-10 p- -0
0-3-8
LOADING (pst)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.98
Vert(LL)
0.09
10
>999
360
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.57
Vert(CT)
-0.13
7-8
>999
240
BCLL 0.0 *
Rep Stress Incr
YES
WB 0.78
Horz(CT)
0.02
7
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 134 Ib FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1,W5: 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied, except end
verticals.
BOT CHORD
Rigid ceiling directly applied or 6-7-9 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
11 =
1291/0-8-0 (min. 0-1-8)
7 =
1026/Mechanical
Max Horz
11 =
206(LC 12)
Max Uplift
11 =
-703(LC 8)
7 =
-534(LC 13)
Max Grav
11 =
1291(LC 1)
7 =
1026(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-953/589, 2-3=-1320/1321,
3-4=-1054/1405, 4-5=-1198/1454,
5-6=-338/390, 6-7= 332/483
BOT CHORD
1-11=-786/1052, 10-11=-939/1052,
9-10=-932/1051, 8-9=-932/1051,
7-8=-1227/1163
WEBS
4-8=-378/312, 2-11=-1054/1817,
5-8=-270/460, 5-7=-1118/1223
NOTES-,
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;GC
for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
I chord live load nonconcurrent with any other live
loads.
5) * This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
10.Opsf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 703 lb uplift at
joint 11 and 534 lb uplift at joint 7.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
city
Ply
A0117222
72005
A17
Hip
2
1
Job Reference (optional)
Al KDor I rUsseS, tort F'Ierce, r-L o4u4o, Deslgn(ga-Itruss.DOm
6-4-8
5x10
2x4 11
... -J I- IL GV I/ IV
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-pDl t?I_kL2DX7_zlTmwal IciIIKnGh2ZOGmT9W7zKGWA
15-1-0 21-1-8
6-7-0 6-0-8
4x8 =
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
TCLL 30.0
Plate Grip DOL
1.25
TC 0.83
Vert(LL)
0.13
7-9
>999
360
TCDL 15.0
Lumber DOL
1.25
BC 0.81
Vert(CT)
-0.16
7-9
>999
240
BCLL 0.0 "
Rep Stress Incr
YES
WB 0.65
Horz(CT)
0.02
15
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2
OTHERS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-1-12 oc
puriins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 6-1-7 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
10 = 1289/0-8-0 (min.0-1-8)
15 = 990/0-3-0 (min.0-1-8)
Max Horz
10 = 187(LC 12)
Max Uplift
10 =-747(LC 8)
15 = 495(LC 9)
Max Grav
10 = 1289(LC 1)
15 = 990(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-1068/775, 2-3=-1364/1346,
3-4=-1209/1472, 4-5=-1410/1442
BOT CHORD
1-10=-864/1117,9-10=-1038/1117,
8-9=-1028/1115, 7-8=-1028/1115,
6-7=-431 /371
WEBS
2-10=-868/1417, 4-7=-1221254,
5-7=-746/865, 5-15=-1067/1147
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10,; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. 11; Exp D; Encl.,1 GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions
shown; Lumber DO LI=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and a Iy other members.
6) Bearing at joints) 15 considers parallel to grain
value using ANSIlfPI 1 angle to grain formula.
Building designer should verify capacity of bearing
surface.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 747 lb uplift at
joint 10 and 495 lb uplift at joint 15.
LOAD CASE(S)
Standard
II
I
i
I
I
I
20-10-0
Dead Load Defl. =1116 in
v
15
Iop
0
2x4 II
PLATES GRIP
MT20 244/190
Weight: 133 lb FT = 10%
Job
Truss
Truss Type
city
Ply
72005
A18
Hip
2
1
A0117223
Job Reference (optional)
o. l zu s rvov i z zu i i mi i eK mcusmes, inc. i nu May 3 ug:1 b:32 2u1 a Page 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-HPbFD5 M6LLO18YU1TRprVzRuk54QZOAUQDi2ZzKGW9
0-p-0 2-1-8 7-0-0 16-7-0 — 21-1-8
0 -6 2-1-8 4-10-8 9-7-0 4-6-8
5x10 =
5x6
..., r..- 3 4
2x4 II
3x8 =
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
TCLL 30.0
Plate Grip DOL
10
TC 1.00
Vert(LL)
0.17
7-9
>999
360
TCDL 15.0
Lumber DOL
1.25
SC 0.93
Vert(CT)
-0.23
7-9
>966
240
BCLL 0.0 '
Rep Stress.lncr
YES
WB 0.42
Horz(CT)
0.02
15
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
1 Matrix -MS
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except`
W1: 2x6 SP No.2
OTHERS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied, except end
verticals.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
10 =
128910-8-0 (min.0-1-8)
15 =
990/0-3-0 (min.0-1-8)
Max Horz
10 =
166(LC 12)
Max Uplift
10 =
-782(LC 8)
15 =
-531(LC 9)
Max Grav
10 =
1289(LC 1)
15 =
990(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-1184/930, 2-3=-1423/1361,
3-4=-1315/1501, 4-5=-1458/1479
BOT CHORD
1 -1 0=-936/1197, 9-1 0=-1 109/1197,
8-9=-1093/1193, 7-8=-1093/1193,
6-7=-311 /273
WEBS
3-9=-69/330, 4-7=-185/398,
5-7=-1009/1099, 2-10=-719/1068,
5-15=-1050/1102
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) ' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Bearing atjoint(s) 15 considers parallel to grain
value using ANSI/TPI 1 angle to grain formula.
Building designer should verify capacity of bearing
surface.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 782 lb uplift at
joint 10 and 531 lb uplift at joint 15.
LOAD CASE(S)
Standard
Dead Load Defl. = 118 in
u
c
15
m
2x4 11
20-10-0 21-1-8
4-3-0 0-3-8
PLATES GRIP
MT20 244/190
Weight: 133 Ib FT = 10%
Job
Truss
Truss Type
Qty
Ply
A0117224
72005
A19G
Roof Special Girder
2
1
�
Job Reference (optional)
Al Rbof Trusses, Fort Pierce, FL 34s4e, designLaltruss.com o. I/u b rvuv Ic cu I i 1w I CR 11-bu ICJ, n 1- 1 I1u may a ao. L . as la I aU. 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-h_GOr61 EPGjzccH3ic?WT8bl ax97duycBORMfuzKGW6
0- -0 5-0 0 10-4-0 11-9-8 13-3-0 18-7-0 21-1-8
0- -6 2-1-8 2-10-8 5-4-0 1-5-8 1-5-8 5 4-0 2-6-8
3x8 11
LOADING (psf)
SPACING-
2-0-0
TCLL
30.0
Plate Grip DOL
1.25
TCDL
15.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
NO
BCDL
10.0
Code FBC2017/TPI2014
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2
OTHERS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 4-4-1 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 6-6-15 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
15 =
1219/0-8-0 (min. 0-1-8)
20 =
964/0-3-0 (min. 0-1-8)
Max Horz
15 =
158(LC 8)
Max Uplift
15 =
-1018(LC 4)
20 =
-789(LC 9)
Max Grav
15
1219(LC 1)
20 =
964(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-880/772, 2-3=-1090/1002,
3-21=-2216/1634,21-22=2216/1634,
4-22=-2216/1634, 4-23=-2472/1852,
5-23=-2433/1857, 5-24=-2369/1770,
6-24=-2408/1767, 6-25=-2166/1562,
25-26=-2166/1562, 7-26=-2166/1562,
7-8=-1173/968
BOT CHORD
1-15=-729/889, 14-15=-887/889,
14-27=-870/869, 27-28=-870/869,
13-28=-870/869, 13-29=-1258/1822,
12-29=-1258/1822, 12-30=-1258/1822,
11 -30=1 258/1822, 11-31=-845/1052,
31-32=-845/1052, 10-32=-845/1052,
9-10=-219/263
5x8 =
20-10-0
Dead Load Defl. = 1116 in
CSI.
DEFL.
in (loc)
I/deft
Ud
PLATES GRIP
TC 0.59
Vert(LL)
0.1513-14
>999
360
MT20 244/190
BC 0.75
Vert(CT)
-0.1813-14
>999
240
WB 0.56
Horz(CT)
0.01 20
n/a
n/a
Matrix -MS
Weight: 143 lb FT = 10%
BOT CHORD
1-15=-729/889, 14-15=-887/889,
14-27=-870/869, 27L 28=-870/869,
13-28=-870/869, 13L29=-1258/1822,
12-29=-1258/1822, (12-30=-1258/1822,
11-30=-1258/1822, 11-31=-845/1052,
31-32=-845/1052, 10-32=-845/1052,
9-10=-219/263
WEBS
3-14=-330/273,3-13=-826/1464,
4-13=-1222/1007,5i13=-828/953,
5-11=-675/844, 6-11=-1154/938,
7-11=-739/1211, 7-10=416/391,
8-10=-755/946, 2-15=-641/566,
8-20=-1019/835 1
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10 Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl.,IGCpi=0.18; MWFRS (envelope);
cantilever left exposed ; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequatedrainageto prevent water
ponding. 1
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) . This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Bearing atjoint(s) 20 considers parallel to grain
value using ANSI/TPI 1 angle to grain formula.
Building designer should verify capacity of bearing
surface.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 1018 lb uplift
at joint 15 and 789 Ib',uplift at joint 20.
1
8) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 206
lb down and 250 lb up at 5-0-0, 92 lb down and 137 lb
up at 7-0-12, 99 lb down and 106 lb up at 9-0-12, 39
lb down and 33 lb up at 11-0-12, 39 lb down and 33 lb
up at 12-6-4, 99 lb down and 106 lb up at 14-6-4, and
92 lb down and 137 lb up at 16-6-4, and 187 lb down
and 231 lb up at 18-7-0 on top chord, and 110 lb
down and 209 lb up at 5-0-0, 18 lb down and 32 lb up
at 7-0-12, 20 lb down at 9-0-12, 21 lb down at
11-0-12, 21 lb down at 12-6-4, 20 lb down at 14-6-4,
and 18 lb down and 32 lb up at 16-6-4, and 81 lb
down and 142 lb up at 18-6-4 on bottom chord. The
design/selection of such connection device(s) is the
responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-90, 3-4=-90, 4-5=-90, 5-6=-90, 6-7=-90,
7-8=-90, 9-17=-20
Concentrated Loads (lb)
Vert: 3=95(B) 7=63(B) 14=101(B) 10=69(B)
21=-32(B) 22=39(13) 25=-39(B) 26=-32(B)
27=-18(B) 28=-12(B)29=-14(B) 30=-14(B)
31=-12(B) 32=-18(B)
Job
Truss
Truss Type
Qty
Ply
72005
B01 G
Hip Girder
1
3
A0117225
Job Reference (optional)
i -01 Muaoes, run rierce, rL .r+ayo, uesignLa iu
5.00 V2
5x10 = 5x6 =
8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3
19.- 18 17 - co io 15m 14 z/ zo 1.3 `12 n1 az 33 11 10
4x10 II 7x6 = 6x6 = 6x6 = 6x8 = 6x6 = 7x6 = 3x8 II
15:38 2018 Pagel
Bg2tMgl4GDzKGW3
Dead Load Defl. = 1/8 in
53-2
53.2
3x6 =
11-3-9 16-5-10 19-4-6
6-0-7 52-1 2-10.12
5x6 =
2 -r
52-1
30-6-14
6-0.7
33-0-5
32-8-13
2-1-15
0-3-8
Plate Offsets (X,Y)-
[5:0-3-15,0-2-13], [9:0-2-0,0-1-12], [10:04-12,0-2-14],
[12:0-3-0,04-8], [14:0-4-0,0-4-0], [15:0-2-8,0-1-8], [16:0-2-15,Edge], [17:0-3-0,0-4-0], [19:0-5-1
,0-1-21
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL.
in (loc) I/defl
L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.47
Vert(LL)
0.23 15-17 >999
360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.82
Vert(CT)
-0.25 15-17 >999
240
BCLL 0.0 '
Rep Stress Incr NO
WB 0.82
Horz(CT)
0.06 10 n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 908 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6. SP 240OF 2.0E 'Except*
B2: 2x6 SP No.2
WEBS 2x4 SP No.3 `Except*
W1,W10: 2x8 SP 240OF 1.8E
W2,W9: 2x4 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size)
19 =
10357/0-8-0 (min.0-2-14)
10 =
10449/Mechanical
Max Horz
19 =
289(LC 8)
Max Uplift
19 =
-7260(LC 8)
10 =
-6997(LC 9)
Max Grav
19 =
10357(LC 1)
10 =
10449(LC 1)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-11436/8146, 2-3=-12479/9157,
3-4=-12408/9173, 4-5=-10521/7778,
5-6=-9589/7167, 6-7=-10424/7656,
7-8=-10668/7512,8-9=-5735/3862,
1-19=-9108/6528, 9-10=-10235/6877
BOT CHORD
19-20=-664/564, 20-21=-664/564,
18-21=-664/564,18-22=-7692/10449,
22-23=-7692/10449, 17-23= 7692/10449,
17-24=-8455/11453, 24-25=-8455/11453,
16-25=-8455/11453, 15-16=-8455/11453,
15-26=-6984/9672, 14-26=-6984/9672,
14-27=-6735/9775, 27-28=-6735/9775,
28-29=-6735/9775, 13-29=-6735/9775,
13-30=-6735/9775, 12-30=-6735/9775,
12-31=-3488/5188, 31-32=-3488/5188,
BOT CHORD
19-20=-664/564,20-21=-664/564,
18-21=-664/564, 18-22=-7692/10449,
22-23=-7692/10449, 17-23=-7692/10449,
17-24=-8455/11453, 24-25=-8455/11453,
16-25=-8455/11453, 15-16=-8455/11453,
15-26=-6984/9672, 14-26=6984/9672,
14-27=-6735/9775, 27-28=-6735/9775,
28-29=-6735/9775, 13-29=-6735/9775,
13-30=-6735/9775, 12-30=-6735/9775,
12-31 =-3488/5188, 31-32=-3488/5188,
32-33=-3488/5188, 11-33=-3488/5188,
11-34=-186/274,10-34=-186/274
WEBS
2-18=-1519/1321,2-17=-1094/1270,
4-17=-1977/2598, 4-15=-3055/2477,
5-15=-3249/4052, 5-14=-463/479,
6-14=-2737/3583, 7-14=-556/231,
7-12=-134/444, 1-18=-7708/10842,
8-12=-4070/5632, 8-11=-5330/3945,
9-11=-6180/9198
NOTES-
1) 3-ply truss to be connected together with 10d
(0.131 "x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows
staggered at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0
oc.
Bottom chords connected as follows: 2x6 - 2 rows
staggered at 0-7-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies,
except if noted as front (F) or back (B) face in the
LOAD CASE(S) section. Ply to ply connections have
been provided to distribute only loads noted as (F) or
(B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered
for this design.
4) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
Lumber DOL=1.60 plate grip DOL=1.60
5) Provide adequate drainage to prevent water
ponding.
6) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
7) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
I O.Opsf.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 7260 lb uplift
at joint 19 and 6997 lb uplift at joint 10.
10) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s)
1011 lb down and 657 lb up at 1-3-4, 1020 lb down
and 641 lb up at 3-3-4, 1020 lb down and 669 lb up at
5-3-4, 1020 lb down and 754 lb up at 7-34, 1020 lb
down and 854 lb up at 9-3-4, 1020 lb down and 854 lb
up at 11-3-4, 1020 lb down and 854 lb up at 13-34,
1020 lb down and 854 lb up at 15-34, 1011 lb down
and 859 lb up at 17-34, 1011 lb down and 859 lb up
at 19-3-4, 1011 lb down and 859 lb up at 19-8-12,
1011 lb down and 751 lb up at 21-8-12, 1011 lb down
and 667 lb up at 23-8-12, 1011 lb down and 647 lb up
at 25-8-12, 1011 lb down and 658 lb up at 27-8-12,
and 1006 lb down and 573 lb up at 29-8-12, and 1006
lb down and 554 lb up at 31-8-12 on bottom chord.
The design/selection of such connection device(s) is
the responsibility of others.
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=125
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-5=-90, 5-6=-90, 6-9=-90, 10-19=-20
Concentrated Loads (lb)
Vert: 18=-1020(F) 17=-1020(F) 14=-1011(F)
20=-1011(F) 21=-1020(F)22=-1020(F) 23=-1020(F)
24=-1020(F)25=-1020(F)26=-1011(F) 27=-1011(F)
28=-1011(F)30=-1011(F)31=-1011(F)32=-1011(F)
33=-1006(F)34=-1006(F)
Job
Truss
Truss Type
Qty
PIY
A0117226
72005
B02
Roof Special
2
1
Job Reference (optional)
Al Root I russes, tort Fierce, rL J4`J4b, cesignLa nruss.cwm
6-0-7
4x6
6x6 - 3
2
4x8
1
14 13
3x10 II 4x4 =
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-alWvhU41TVDP5DagxR3Sd_IhGZdCZgwC5OPaofzKGW2
7-11-0 1 24-6-7 , 31-8-8
5x6 =
5.00 12
5
5x6
4
6x6
6
12 17 11 10 18 9
3x4 = 4x6 = 3x8 = 3x4 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
Ud
TCLL 30.0
Plate Grip DOL
1.25
TC 0.74
Vert(LL)
0.11 12
>999
360
TCDL 15.0
Lumber DOL
1.25
BC 0.36
Vert(CT)
-0.12 10-12
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WI 0.69
Horz(CT)
0.11 16
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W1: 2x6 SP No.2, W9: 2x4 SP No.2
OTHERS 2x8 SP 240OF 1.8E
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 4-11-8 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 5-1-2 oc bracing.
WEBS
1 Row at midpt
4-10, 5-10, 6-10, 1-13, 7-9
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
14 =
1719/0-8-0 (min.0-2-0)
16 =
1661/0-5-1 (min. 0-1-8)
Max Horz
14 =
352(LC 12)
Max Uplift
14 =
-933(LC 12)
16 =
-857(LC 13)
Max Grav
14 =
1719(LC 1)
16 =
1661(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-1962/2143, 2-3=-2110/2460,
3-4=-1921/2475, 4-5=-1647/2148,
5-6=-1651/2154, 6-7=-1611/1863,
1-14=-1657/1878
BOT CHORD
13-14=-404/173,12-13=-2110/1736,
12-17=-2085/1859,11-17=-2085/1859,
10-11=-2085/1859,10-18=-155111425,
9-18=-1551/1425, 8-9=-312/265
WEBS
2-13=-631/845, 4-10=-719/1010,
5-10=-852l702, 6-10=-213/283,
WEBS I.
2-13=-631/845, 4-10=-719/1010,
5-10=-852/702, 6-10=-213/283,
6-9=-649/92411-13-1896/1805,
7-9=-1474/1380,7-16=-1713/1936
NOTES-
1) Unbalanced roof ive loads have been considered
for this design.
2) Wind: ASCE 7-1q; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf, h=39ft;
Cat. II; Exp D; Encl.,1 GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces
R MWFRS for reactions shown; Lumber DOL=1.60
plate grip DOL=1.60'
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
4)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
10.0psf.
5) Bearing at joints) 16 considers parallel to grain
value using ANSI/TP,I 1 angle to grain formula.
Building designer should verify capacity of bearing
surface.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 933 lb uplift at
joint 14 and 857 lb uplift at joint 16.
LOAD CASE(S)
Standard
8
4x4 11
PLATES GRIP
MT20 244/190
Weight: 263 Ib FT = 10%
Job
Truss
Truss Type
Qty
Ply
72005
B03
Roof Special
6
1
A0117227
Job Reference (optional)
�� • •��� �• U W,=1.• 11 I o. ILu 5 1vuv 1c zu 1 i mi i eK muustnes, inc. i nu may h ue:"1 o:4u zul i1 rage i
I D:nKMLCG99vHyLG9D5?YIAEyzKd3P-2y4Hug5N EpLGiN90V9bhABltcylT17CLKg97L5zKGW 1
541-2 11-3 9 17-11-0 24 6 7 31 8-8
3-2 6-0 7 6-7-6 6-7-7 7-2-1
5x6 =
5.00 F12
5
4x
0
14 13 12 11 10 itt 9 8
3x10 11 44 = 3x4 = 4x6 = 3x8 = 3x4 = 4x4 11
24-6-7
LOADING(psf)
TCLL 30.0
TCDL 15.0
BCLL 0.0 *
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TP12014
CSI.
TC 0.70
BC 0.36
WB 0.69
Matrix -MS
DEFL. in (]cc) I/deft L/d
Vert(LL) 0.11 12 >999 360
Vert(CT) -0.12 10-12 >999 240
Horz(CT) 0.10 16 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 263 lb FT = 10W
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS
WEBS 2x4 SP No.3 *Except*
2-13=-629/843, 4-1 0=-720/1 011,
W1: 2x6 SP No.2, W9: 2x4 SP No.2
5-10=-845/696, 6-10=-205/278,
OTHERS 2x8 SP 2400F 1.8E
6-9=-654/930, 1-13=-1891/1800,
BRACING-
7-9=-1493/1397, 7-16=-1706/1927
TOP CHORD
Structural wood sheathing directly applied or 4-11-10 cc
i NOTES-
purlins, except end verticals.
1) Unbalanced roof live loads have been considered
BOT CHORD
for this design.
Rigid ceiling directly applied or 5-14 cc bracing.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
WEBS
Vasd=139mph; TCDL=S.Opsf; BCDL=5.Opsf; h=39ft;
1 Row at midpt
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
4-10, 5-10, 6-10, 1-13, 7-9 !
and C-C Exterior(2) zone;C-C for members and forces
MiTek recommends that Stabilizers and required
MWFRS for reactions shown; Lumber DOL=1.60
cross bracing be installed during truss erection, in
plate grip DOL=1.60
accordance with Stabilizer Installation guide.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
REACTIONS. (lb/size)
loads.
14 = 1715/0-8-0 (min. 0-2-0)
4) * This truss has been designed for a live load of
16 = 1665/0-6-12 (min. 0-1-8)
20.Opsf on the bottom chord in all areas where a
Max Horz
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
14 = 352(LC 12)
bottom chord and any other members, with BCDL =
Max Uplift
10.Opsf.
14 =-931(LC 12)
5) Bearing at joint(s) 16 considers parallel to grain
16 =-859(LC 13)
value using ANSlfTPI 1 angle to grain formula.
Max Grav
Building designer should verify capacity of bearing
14 = 1715(LC 1)
surface.
16 = 1665(LC 1)
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 931 lb uplift at
FORCES. (lb)
joint 14 and 859 lb uplift at joint 16.
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
LOAD CASE(S)
1-2=-1957/2138, 2-3=-2103/2452,
Standard
3-4=-1915/2468, 4-5=-1639/2140,
5-6=-1643/2146, 6-7=-1598/1848,
1-14=-1653/1874
BOT CHORD
13-14=-404/172, 12-13=-2105/1732,
12-17=-2078/1853, 11-17=-2078/1853,
10-11=-2078/1853, 10-18=-153611412,
9-18=-1536/1412; 8-9=-281/237
WEBS
2-13=-629/843, 4-1 0=-720/1 011,
5-10=-845/696, 6-10=-205/278,
Job
Truss
Truss Type
Qty
Ply
A0117228
72005
B04G
Hip Girder
1
Job Reference o tional
Al Rbof Trusses, Fort Pierce, FL 34946, design@altruss.com
b.7ZU S NOV 7Z ZUl / mi r eK Inausmes, inc. I nu may a u21: 1 u.+a zu io raga i
I D: nKMLCG99vHyLG9D5?YIAEyzKd3P-SXIPW r7G WjkgZrubAH80ngwSFArLVSgnOeNnxQzKGW_
lq-" , 24-6-7 30-6-14 , 33-0-5
5 00 12 I 5x10 = 5x6 =
3x4
a3�
3x
Sx8 i
1
UJ
19 20 21 18 22 23 24 17 25 A 27
4x10 11 7x6 = 6x6 =
-121,_ 10j .0-4-1
3x4
7
4x4
8 5x6
9
16 15 128 29 30 13 312 33" 34 3511 36 10
6x6 = 6x8 = 6x6 = 7x6 = 3x8 II
3x6 = 5x6 = 33-0-5
4:0-4-0,0-3-121, [1
Dead Load Defl. = 1/8 in
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.42
Vert(LL)
0.22 15-17
>999
360
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.92
Vert(CT)
-0.27 15-17
>999
240
BCLL 0.0
Rep Stress Incr
NO
WB 0.83
Harz(CT)
0.07 10
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 908 lb FT = 10%
LUMBER -
TOP CHORD
2x6 SP No.2
BOT CHORD
2x6 SP 240OF 2.0E *Except*
BOT CHORD
B2: 2x6 SP No.2
19-20=-741/604, 20 21=-741/604,
WEBS
2x4 SP No.3 *Except*
18-21=-741/604, 18i 22=-6961/10662,
W1,W10: 2x8 SP 240OF 1.8E
22-23=-6961/10662, 23-24=-6961/10662,
W2,W9: 2x4 SP No.2
17-24=-6961/10662y 17-25=-7255/11867,
BRACING-
25-26=-7255/11867,, 26-27=-7255/11867,
TOP CHORD
16-27=-7255/11867, 15-16=-7255/11867,
Structural wood sheathing directly applied or 6-0-0 oc
15-28=-5990/10068f 14-28=-5990/10068,
purlins, except end verticals.
CHORD
14-29=-5788/101501 29-30=-5788/10150,
30-31=-5788/10150[ 13-31=-5788/10150,
BOT
Rigid ceiling directly
applied or 10-0-0 oc bracing.
13-32=-5788/101% 12-32=-5788/10150,
12-33=-3075/5296, 33-34=-3075/5296,
REACTIONS.
(lb/size)
34-35=-3075/5296, �11-35=-3075/5296,
19 =
1035210-8-0 (min. 0-2-14)
11-36=-163/275, 10r36=-163/275
10 =
10484/Mechanical
WEBS
Max Horz
2-18=-18231797, 2-17=-519/1682,
19 =
289(LC 8)
4-17=-1620/2770,4-15=-3220/2137,
5-15=-3061/4728, 5i14=-994/716,
Max Uplift
19 =
-6731(LC 8)
6-14=-2298/3729, 7 1 14=-686/357,
10 =
-6185(LC 9)
7-12=-270/483, 1-18=-6821/11032,
Max Grav
8-12=-3414/5958, 8111=-5549/3364,
19 =
10352(LC 1)
9-11=-5452/9398
10 =
10586(LC 2)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-1 166817351, 2-3=-1 2915/7857,
3-4=-12856/7872, 4-5=-10920/6704,
5-6=-9844/6104, 6-7=-10679/6513,
7-8=-11061/6485, 8-9=-5856/3407,
1-19=-9278/5853, 9-10=-10457/6065
BOT CHORD
19-20=-741/604, 20-21=-741/604,
18-21=-741/604,18-22=-6961/10662,
22-23=-6961/10662, 23-24=-6961/10662,
17-24=-6961 /10662, 17-25=-7255/11867,
25-26=-7255/11867, 26-27=-7255/11867,
16-27=-7255/11867, 15-16=-7255/11867,
15-28=-5990/10068, 14-28=-5990/10068,
14-29=-5788/10150, 29-30=-5788/10150,
30-31=-5788/10150, 13-31=-5788/10150,
13-32=-5788/10150, 12-32=-5788/10150,
12-33=-3075/5296, 33-34=-3075/5296,
NOTES-
1) 3-ply truss to be connected together with 1 Od
(0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows
staggered at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0
oc.
Bottom chords connected as follows: 2x6 - 2 rows
staggered at 0-5-0 oc.
Webs connected as follows: 2x4 -1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies,
except if noted as front (F) or back (B) face in the
LOAD CASE(S) section. Ply to ply connections have
been provided to distribute only loads noted as (F) or
(B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered
for this design.
4) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
Lumber DOL=1.60 plate grip DOL=1.60
5) Provide adequate drainage to prevent water
ponding.
6) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
7) * This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
10.Opsf.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 6731 lb uplift
at joint 19 and 6185 lb uplift at joint 10.
10) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s)
1490 lb down and 1339 lb up at 2-3-4, 1011 lb down
and 672 lb up at 4-3-4, 1011 lb down and 666 lb up at
6-3-4, 1011 lb down and 657 lb up at 8-3-4, 1174 lb
down and 583 lb up at 10-3-4, 1174 lb down and 611
III up at 12-3-4, 1174 lb down and 696 lb up at 14-3-4
, 1174 Ib down and 796 Ib up at 16-3-4, 1174 lb down
and 796 lb up at 17-8-12, 1174 lb down and 796 lb up
at 19-8-12, 1174 lb down and 689 lb up at 21-8-12,
1174 lb down and 604 lb up at 23-8-12, 1174 lb down
and 585 lb up at 25-8-12, 1174 lb down and 596 lb up
at 27-8-12, and 1006 lb down and 573 lb up at
29-8-12, and 1006 Ib down and 554 lb up at 31-8-12
on bottom chord. The design/selection of such
connection device(s) is the responsibility of others.
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
Plate Increase=1.25
Uniform Loads (plo
Vert: 1-5=-90, 5-6=-90, 6-9=-90, 10-19=-20
Concentrated Loads (lb)
Vert: 16=-1073(B) 20=-1490(B) 21=-1011(B)
22=-1011(B) 23=-1011(B) 24=-1073(B)25=-1073(B)
27=-1 073(B) 28=-1 073(B) 29=-1 073(B) 30=-1 073(B)
32=-1 073(B) 33=-1 073(B) 34=-1 073(B) 35=-1 006(B)
36=-1006(B)
Job
Truss
Truss Type
City
Ply
72005
C01 G
Hip Girder
1
1
A0117229
i
Job Reference (optional)
m r r%uor r russes, ruri rierce, rL 34946, design Cwalrruss.com
8.120 s Nov 12 2017 MITek Industries, Inc. Thu May 3 09:15:45 2018
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-PvtAxX9W2L_Yp82_IiAstF?f9zcvzRT4Uysu
3x10 11 3x6 = — 3x10 = 3x10 11
17-3-4
-0-Q-12 4-1 1-4
12-3-4 16-110 17-2n8
Ub12 4-11.4 74-0 4-7-12 3
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc)
I/deft
L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.97
Vert(LL) 0.23
8-10
>882
360
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.60
Vert(CT) 0.21
8-10
>954
240
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.49
Horz(CT) -0.02_
7
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
I Matrix -MS
Weight: 150 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 `Except'
W1: 2x8 SP 240OF 1.8E
OTHERS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 44-14 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 3-11-10 oc bracing.
WEBS
1 Row at midpt 2-10, 5-8
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
11 =
1471/0-8-0 (min.0-1-12)
7 =
1470/0-8-0 (min.0-1-12)
Max Horz
11 =
-220(LC 32)
Max Uplift
11 =
-2537(LC 4)
7 =
-2363(LC 4)
Max Grav
11 =
1471(LC 1)
7 =
1470(LC 1)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-1333/2678, 3-14=-1145/2558,
14-15=-1145/2558, 15-16=-1145/2558,
4-16=-1 145/2558,4-5=-1331/2701,
2-11=-1435/2498, 5-7=-1433/2379
BOT CHORD
10-17=-2283/1148, 17-18=-2283/1148,
9-18=228311148, 8-9=-2283/1148
WEBS
3-10=-370/55, 4-8=-379/53,
2-10=-2628/1290, 5-8=-2527/1286
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left and
right exposed; porch left exposed; Lumber DOL=1.60
plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
I loads.
5) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
"bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 2537 lb uplift
at joint 11 and 2363 lb uplift at joint 7.
7) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 308
lb down and 495 lb up at 4-11-4, 113 lb down and 181
lb up at 7-0-0, 113 lb down and 181 lb up at 8-7-4,
and 113 lb down and 181 lb up at 10-2-8, and 308 lb
down and 495 lb up at 12-3-4 on top chord, and 63 Ib
down and 767 lb up at 4-11-4, 64 lb down and 252 lb
up at 7-0-0, 64 lb down and 252 lb up at 8-7-4, and
64 lb down and 252 lb up at 10-2-8, and 63 lb down
and 767 lb up at 12-2-8 on bottom chord. The
design/selection of such connection device(s) is the
responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plo
Vert: 1-2=-90, 2-3=-90, 3-4=-90, 4-5=-90, 5-6=-90,
7-11=-20
Concentrated Loads (lb)
Vert: 3=-195(F) 4=-195(F) 9=-26(F) 10=-10(F)
8=-10(F) 14=-72(F) 15=-72(F) 16=-72(F) 17=-26(F)
18=-26(F)
Truss
Truss Type
Qty
Ply
A0117230
r72005
CO2
Hip
1
1
'
Job Reference (optional)
Al ftaot r fusses, fort fierce, rL d4V40, 0es19nLa i IrLSS-WIT) „
t6��•I �,
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-RY9t98pe6PQIcArQh5PSYxYN1 hiwNEiccSXlzKGVx
5-9-13 9-1-13 1 14-11-10 _
5x6 � 5x6 =
5.00 12 2
3
5x6
'
10
1
V.
I1FA
8 t
6
53x8 II
3x8 II
3x4 —
3x4 =
5-9-13 ,
9-1-13 14-8-2
4-,
111-10
5 9-13
3�3-0 5-6-5
0-3-8
Plate Offsets (X Y)- [1.0-2-4 0-2-12] [4.0-2-4 0-2-12] [5:0-4-12 0-2-4] [8:0-4-12
0-0-41
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft
L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.54
Vert(LL) 0.07 5-6 >999
360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.31
Vert(CT) 0.06 5-6 >999
240
BCLL 0.0
Rep Stress Incr YES
WB 0.32
Horz(CT) -0.01 5 n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 115 Ib FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
2) Wind: ASCE 7-10; VUlt=180mph (3-second gust)
BOT CHORD 2x6 SP No.2
Vasd=139mph; TC , L=5.Opsf, BCDL=5.Opsf; h=39ft;
WEBS 2x4 SP No.3 `Except`
Cat. ll; Exp D; Encl.l, GCpi=0.18; MWFRS (envelope)
W1: 2x6 SP No.2
and C-C Exterior(2)Izone; porch left exposed;C-C for
BRACING-
members and forces 8 MWFRS for reactions shown;
TOP CHORD
Lumber DOL=1.60 plate grip DOL=1.60
Structural wood sheathing directly applied or 6-0-0 oc
3) Provide adequate drainage to prevent water
purlins, except end verticals.
ponding.
BOT CHORD
4) This truss has been designed for a 10.0 psf bottom
Rigid ceiling directly applied or 5-10-1 oc bracing.
chord live load nonconcurrent with any other live
WEBS
loads.
1 Row at midpt 1-7, 4-6
5) `This truss has been designed for a live load of
MiTek recommends that Stabilizers and required
20.Opsf on the bottom chord in all areas where a
cross bracing be installed during truss erection, in
rectangle 3-6-0 tall 0 2-0-0 wide will fit between the
accordance with Stabilizer Installation guide.
bottom chord and ay other members, with BCDL =
10.Opsf.
REACTIONS. (lb/size)
6) Provide mechani I connection (by others) of truss
8 = 798/0-10-9 (min. 0-1-8)
to bearing plate capable of withstanding 816 lb uplift at
5 = 798/0-10-9 (min. 0-1-8)
joint 8 and 818 Ib up)ift at joint 5.
Max Horz
8 = -77(LC 13)
Max Uplift
LOAD CASE(S)
8 =-816(LC 8)
Standard
5 =-818(LC 8)
Max Grav
8 = 798(LC 1)
5 = 798(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-724/1792, 2-3=-572/1815,
3-4=-724/1792, 1-8=-737/1689,
4-5=-737/1689
BOT CHORD
6-7=-1466/572
WEBS
1-7=-1415/564, 4-6=-1415/564
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
Job
Truss
Truss Type
Qty
Ply
72005
CA
Corner Jack
30
1
A0117232
Job Reference (optional)
• • •""• • •"""`-", • `�, • • "-•`^" • '- `�""�"h `���"J"l_.�'�'�+��•�^+�'� 0. 1ZU D IVVV 14 zu l / IWI I eK Inousines, Inc. I nu May d utcio:4/ zuiu rage i
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-LI?wMDAmayEG2SBM P7DKyg4EKnPdRReNxGM?3BzKGVw
0-6 1-0-0 a'
0-TO-6 1-0-0
5.00 F12
2
4x4 =
3
3x4 =
0-8-8
1-0-0 ,
0-8-8
0-3-8
Plate Offsets (X,Y)—
r1:0-0-11,0-0-71, rl:Edge,0-3-11
I
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/defl
L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.03
Vert(LL)
0.00 6
n/r
90
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.07
Vert(CT)
-0.00 6
n/r
80
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT)
0.00
n/a
n/a
BCDL 10.0
Code FBC2017/fP12014
Matrix -MP
Weight: 5 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 1-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 = -0/Mechanical
3 = 112/Mechanical
Max Horz
2 = 109(LC 1)
3 = 117(LC 8)
Max Uplift
3 =-109(LC 8)
Max Grav
3 = 112(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-275/100
BOT CHORD
1-3=-109/379
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 109 lb uplift at
joint 3.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
A0117231
72005
CJ1-3
Corner Jack I
6
1
?
Job Reference o tional
A] KDor trusses, rorc rlerce, rL J4y40, uesiyuLa a uaa.ww
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-LI?wMDAmayEG2SBMP7DKyg4CwnKERReNxGM?3BzKGVw
3.00 F12 2
1
Ti
B1
3
U4L
STRAP TOP AND BOTTOM CHORD WITH LSTA12
STRAP
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL.
in (loc)
I/defl
Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.18
Vert(LL)
0.00 6
n/r
90
MT20 2441190
TCDL 15.0
Lumber DOL
1.25
BC 0.41
Vert(CT)
-0.00 6
n/r
80
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
0.00
n/a •
n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MP
Weight: 3 lb FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING- . LOAD CASE(S)
TOP CHORD Standard
Structural wood sheathing directly applied or 1-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
-O/Mechanical
3 =
115/Mechanical
Max Horz
2 =
-130(LC 8)
3 =
154(LC 8)
Max Uplift
3 =
-136(LC 8)
Max Grav
3 =
115(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-347/119
BOT CHORD
1-3=-124/406
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 136 lb uplift at
joint 3.
Job
Truss
Truss Type
Oty
Ply
72005
CAC
CORNER JACK
4
1
A0117233
Job Reference o tional
-- --• - - - -- --• ----� �-.- ----•--••• �. <u a 1- ,L GU, / ,v,11 Cn InOU5lne5, InG. r nu May J U`J:10:4b ZU1S Vage 1
I D: n KM LCG99vHyLG9 D5?YIAEyzKd3 P-pUZ1aZBOLGM7g cmZzgkZUtdGq bj2AUtXAw5YcezKG Vv
2-0-12 0-111 -A:2-0-12 0-114
5.00 12
7vfi 11 9
Plate Offsets (X,Y)— [2:0-4-6 0-1-81
1
LOADING(psf)
SPACING- 2-6-0
CSI.
DEFL. in (loc) I/deft L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.62
Vert(LL) 0.00 ' 5 >999 360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.25
Vert(CT) -0.00 5 >999 240
BCLL 0.0
Rep Stress Incr NO
WB 0.00
Horz(CT) 0.00 n/a n/a
BCDL 10.0
Code FBC2017fTP12014
Matrix -MR
Weight: 19 lb FT =10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
OTHERS 2x6 SP No.2
BRACING -
TOP CHORD
2-0-0 oc purlins, except end verticals
(Switched from sheeted: Spacing > 2-0-0).
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size)
5 =
205/0-8-0 (min. 0-1-8)
3 =
-0/Mechanical
4 =
139/Mechanical
Max Horz
5 =
183(LC 9)
3 =
134(LC 1)
Max Uplift
5 =
-153(LC 8)
4 =
-156(LC 8)
Max Grav
5 =
205(LC 1)
4 =
139(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-5=-326f756
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ; end
vertical left exposed; porch left exposed;C-C for
members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 153 lb uplift at
joint 5 and 156 lb uplift at joint 4.
6) Graphical purlin representation does not depict the
size or the orientation of the purlin along the top and/or
bottom chord.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
A0117235
72005
CJ3
Corner Jack
16
1
Job Reference o tional
Al Rbof Trusses, Fort Pierce, FL 34946, design@altruss.com 8.120 s Nov 12 2017 MI Fek Industries, Inc. I Mu May s ua:1 b:aa ZU1 a rage i
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-Hh6hnvCO6ZU_HmLIXYFol5AX1 b2rvKbgPar684zKGVu
0- -6 3-0-0
0- -6 j 3-0-0
3
T
U6 11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
L/d
TCLL 30.0
Plate Grip DOL
1.25
TC 0.20
Vert(LL)
0.00
5
>999
360
TCDL 15.0
Lumber DOL
1.25
BC 0.28
Vert(CT)
0.00
5
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.10
Horz(CT)
0.01
3
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 3-0-0 oc
puriins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
3 =
-108/Mechanical
4 =
-162/Mechanical
5 =
597/0-8-0 (min. 0-1-8)
Max Horz
5 =
111(LC 12)
Max Uplift
3 _
-108(LC 1)
4 =
-162(LC 1)
5 =
-507(LC 8)
Max Grav
3 =
79(LC 8)
4 =
111(LC 8)
5 =
597(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
WEBS
2-5=-306/780
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ; porch
left exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) ` This truss has t
20.Opsf on the bottc
rectangle 3-6-0 tall
bottom chord and a
4) Refer to girder(s)
5) Provide mechani
to bearing plate car
joint 3, 162 lb uplift
LOAD CASE(S)
Standard
en designed for a live load of
1 chord in all areas where a
12-0-0 wide will fit between the
/ other members.
or truss to truss connections.
iI connection (by others) of truss
ble of withstanding 108 lb uplift at
: joint 4 and 507 lb uplift at joint 5.
PLATES GRIP
MT20 244/190
Weight: 17 lb FT = 10%
Job
Truss
Truss Type
Qty
Ply
72005
CJ3-3
Comer Jack
4
1
A0117234
Job Reference (optional)
., 1 — 11 ubb—, rui t rju—, — �avo, uublgll(w-d ILIubb.wlII 1 0.1 Zu s rvov lZ ZUl / MI r eK Inausines, Inc. I nu May 3 09:1b:49 MIS Page 1
I D: nKM LCG99vHyLG9D5?YIAEyzKd 3P-H h6hnvCO6ZU_H m LIXYFo 15AXYt4?ovL7gPa r684zKG Vu
0 Q-3 3-0-0 a
0-d-3 1 3-0-0
3.00 V2
1
4
2
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
TCLL 30.0
Plate Grip DOL
1.25
TIC 0.24
Vert(LL)
-0.00
4
>999
360
TCDL 15.0
Lumber DOL
1.25
BC 0.47
Vert(CT)
0.00
4
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
0.01
2
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 3-0-0 oc
puriins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 = -35/Mechanical
3 = -298/Mechanical
4 = 658/0-8-0 (min. 0-1-8)
Max Horz
4 = 66(LC 8)
Max Uplift
2 = -36(LC 3)
3 =-298(LC 1)
4 =-743(LC 8)
Max Grav
2 = 41(LC 8)
3 = 316(LC 8)
4 = 658(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ; porch
left exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) . This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 36 lb uplift at
joint 2, 298 lb uplift at joint 3 and 743 lb uplift at joint 4
LOAD CASE(S)
Standard
PLATES GRIP
MT20 244/190
Weight: 15 lb FT = 10%
Job
Truss
Truss Type
Qty
Ply
A0117236
72005
CJ3A
Corner Jack
4
1
Job Reference (optional)
Al KDor I NSSes, ron Ylerce, M J4y40, 0e519f1((La IQU55.WI I
0
3x4 =
0
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-Itg3?ECfttcrvvwx4Fm1 alih7_NGenUpdEafgWzKGVt
3x6 II
LOADING (psf)
TCLL 30.0
TCDL 15.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TP12014
CSI.
TC 0.25
BC 0.33
WB 0.12
Matrix -MP
DEFL. in (loc) I/deft
Vert(LL) -0.00 5 >999
Vert(CT) 0.00 5 >999
Horz(CT) 0.01 3 n/a
L/d
360
240
n/a
LUMBER -
TOP CHORD 2x6 SP No.2
3) ` This truss has been designed for a live load of
BOT CHORD 2x6 SP No.2
20.Opsf on the bottom chord in all areas where a
WEBS 2x6 SP No.2
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
BRACING -
bottom chord and arty other members.
TOP C
4) Refer to girder(s) for truss to truss connections.
Structural wood sheathing directly applied or 3-0-0 oc
St St
5) Provide mechanical connection (by others) of truss
r
to bearing plate capable of withstanding 178 lb uplift at
BOT CHORD
joint 3, 246 lb uplift at joint 4 and 618 Ib uplift at joint 5.
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
LOAD CASE(S) -
accordance with Stabilizer Installation quide.
Standard
REACTIONS. (lb/size)
3 = -178/Mechanical
4 = -246/Mechanical
5 = 750/1-0-0 (min. 0-1-8)
Max Horz
5 = 111(LC 12)
Max Uplift
3 =-178(LC 1)
4 =-246(LC 1)
5 =-618(LC 8)
Max Grav
3 = 136(LC 8)
4 = 204(LC 8)
5 = 750(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
WEBS
2-5=-370/960
I
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ; porch
left exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
j
chord live load nonconcurrent with any other live loads.
PLATES GRIP
MT20 244/190
Weight: 17 lb FT = 10%
Job
Truss
Truss Type
Qty
Ply
72005
CJ3C
Corne'rJack
4
1
A0117237
Job Reference (optional)
• • • • --•�• � •-• . -•• • •�• , •- -'-� , ��y„Vo • uu�o••••,,, . IGV D l- 1 v I / Iv111 uh 111uublr1vs, Inc. i nu may o utv is vu to -Its rage i
i ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-Itg3?ECfttcrvvwx4Fm1 alicG_NVeoNpdEafgWzKGVt
-2-0-12 2-11-4 x
2-0-12 2-11-4
5.00 F12 3
r`
c?
M
6x6 11
2-7-12 2 11
2-7-12 -3-
Plate Offsets (X,Y)— [2:0-3-0,0-2-8),[5:0-4-0,0-0-8]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.56
Vert(LL) 0.01 4-5 >999 360
MT20 2441190
TCDL 15.0
Lumber DOL 1.25
BC 0.38
Vert(CT) 0.01 4-5 >999 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.06 3 n/a n/a
BCDL 10.0
Code FBC2017/TPl2014
Matrix -MR
Weight: 28 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
OTHERS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-11-4 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
5 =
426/0-8-0 (min.0-1-8)
3 =
51/Mechanical
4 =
12/Mechanical
Max Horz
5 =
244(LC 9)
Max Uplift
5 =
-342(LC 8)
3 =
-126(LC 9)
4 =
-142(LC 9)
Max Grav
5 =
426(LC 1)
3 =
51(LC 1)
4 =
46(LC 3)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-5=-386/716
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ; end
vertical left exposed; porch left exposed;C-C for
members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 342 lb uplift at
joint 5, 126 lb uplift at joint 3 and 142 lb uplift at joint 4.
j LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
PIY
A0117239
72005
CJ5
Corner Jack
2
1
Job Reference (optional)
Al r2oof Trusses, Fort Pierce, FL 34946, design@altruss.cc rt
8.I 20 s Nov i2 2017 Mi I eK Inuusines, mu. 1 nu may a UU: i 5- i cu 1 o rage 1
'-D3ERCaDHeBkiX3V8ezHG6W FsUOm7NEOzstKDCzzKGVs
m
N
Plate Offsets (X Y)—
15.0-4-4 0-1-8)
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.21
Vert(LL)
-0.00
4-5
>999
360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.17
Vert(CT)
0.00
4-5
>999
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.10
Horz(CT)
0.01
3
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 26 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-0-0 oc
puriins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
3 =
74/Mechanical
4 =
-10/Mechanical
5 =
483/0-8-0 (min.0-1-8)
Max Horz
5 =
185(LC 12)
Max Uplift
3 =
-118(LC 12)
4 =
-10(LC 1)
5 =
-327(LC 8)
Max Grav
3 =
74(LC 1)
4 =
34(LC 10)
5 =
483(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-406/143
BOT CHORD
1-5=-145/401
WEBS
2-5=-336/822
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3)' This truss has (
20.Opsf on the bottc
rectangle 3-6-0 tall
bottom chord and a
4) Refer to girder(s;
5) Provide mechani
to bearing plate car
joint 3, 10 lb uplift a
LOAD CASE(S)
Standard
een designed for a live load of
m chord in all areas where a
iy 2-0-0 wide will fit between the
iy other members.
for truss to truss connections.
zl connection (by others) of truss
able of withstanding 118 lb uplift at
joint 4 and 327 lb uplift at joint 5.
Job
Truss
Truss Type
Qty
Ply
72005
CJ5-3
Corner Jack
4
1
A0117238
Job Reference (optional)
.. � ' —i o. i cu b rvuv i A cu t i mi r ere inuustnes, inc. r nu may s up: i a:a i zuia rage r
I D: n KM LCG99vHyLG9D 57YIAEyzKd3P-D3 E RCaDHeB kiX3V8ezHG6 W FrwOi UN FdzstKDCzzKGVs
0-Q-3 5-0-0
0- 3 5-0-0
3.00 � 2
1
9
rn
ci
I
1-10 8 ,2-2-8,
1-10-8 0-4-0'
4-8-8
2-6-0
5 0-Q
0
Plate Offsets (X,Y)--
[1:0-1-15,0-0-5]
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
Well
Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.31
Vert(LL)
-0.01
3-4
>999
360
MT20 2441190
TCDL 15.0
Lumber DOL
1.25
BC 0.39
Vert(CT)
-0.01
3-4
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT)
0.01
2
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 24 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 = 91/Mechanical
3 = -40/Mechanical
4 = 494/0-8-0 (min. 0-1-8)
Max Horz
4 =
111(LC 8)
Max Uplift
2 =
-103(LC 12)
3 =
-81(LC 20)
4 =
-560(LC 8)
Max Grav
2 =
91(LC 1)
3 =
44(LC 12)
4 =
494(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ; porch
left exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) . This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 103 lb uplift at
joint 2, 81 lb uplift at joint 3 and 560 lb uplift at joint 4.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
QtY
PIY
A0117240
72005
CJSA
Corner Jack I
4
1
R
Job Reference o tional
Al Koor I rUSses, rOn f'lerce, rL ,wa-+U, uesiynLwa ui Ubb—I II
ID:nKMLCG99vHyLG965?YIAEyzKd3P-hFapPwEvPUsZ8D4KCgoVfjolKo5v6hM65X3mlPzKGVr
5-0-0
rtn-n
5.00 12
3x4 =
5
3x6 I I
3
4
LOADING (psf)
TCLL 30.0
TCDL 15.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TP12014
CSI.
TC 0.20
BC 0.25
WB 0.10
Matrix -MP
DEFL. in (loc) I/defl L/d
Vert(LL) 0.00 4-5 >999 360
Vert(CT) 0.00 4-5 >999 240
Horz(CT) 0.01 3 n/a n/a
LUMBER -
TOP CHORD 2x6 SP No.2
2) This truss has been designed for a 10.0 psf bottom
BOT CHORD 2x6 SP No.2
chord live load non concurrent with any other live
WEBS 2x6 SP No.2
loads. i
3) ` This truss has been designed for a live load of
TOP CHORD
20.Opsf on the bottom chord in all areas where a
Structural wood sheathing directly applied or 5-0-0 oc
rectangle 3-6-0 tall py 2-0-0 wide will fit between the
.
purlinsBOT
bottom chord and any other members.
CHORD
4) Refer to girder(s) for truss to truss connections.
Rigid ceiling directly applied or 10-0-0 oc bracing.
5) Provide mechanical connection (by others) of truss
MiTek recommends that Stabilizers and required
to bearing plate capable of withstanding 107 lb uplift at
cross bracing be installed during truss erection, in
joint 3, 72 lb uplift a) joint 4 and 439 lb uplift at joint 5.
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
LOAD CASE(S)
3 = 57/Mechanical
Standard
4 = -24/Mechanical
5 = 513/1-0-0 (min.0-1-8)
Max Horz
5 = 185(LC 12)
Max Uplift
3 =-107(LC 12)
4 = -72(LC 20)
5 =-439(LC 8)
Max Grav
3 = 57(LC 1)
4 = 14(LC 3)
5 = 513(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-379/143
BOT CHORD
1-5=-145/401
WEBS
2-5=-343/774
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ; porch
left exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
PLATES GRIP
MT20 2441190
Weight: 27 lb FT = 10%
Job
Truss
Truss Type
Qty
Ply
72005
D01 G
Jack -Open
Girder
4
1 1
A0117241
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, designLaltruss.com 8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:15:53 2018 Page 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-ASMBdGFXAo_QmNfWmOJkBxKD7CS9r9VGKBp. HrzKGVq
0-Q-0 3-8-0 5 8-0 7-0-0 "
0- -6 3-8-0 2-0-0 1-4-0
LOADING (psf)
SPACING-
2-0-0
TCLL
30.0
Plate Grip DOL
1.25
TCDL
15.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
NO
BCDL
10.0
Code FBC2017/TPI2014
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
puriins.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. All bearings Mechanical except (jt=length)
8=0-8-0, 7=0-8-0.
(lb) - Max Horz
8=185(LC 8)
Max Uplift
All uplift 100 lb or less at joint(s)
except 5=-112(LC 8), 8=-373(LC 4),
7=-584(LC 23)
Max Grav
All reactions 250 lb or less at joint(s)
5, 6 except 8=445(LC 1), 7=405(LC 32)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
WEBS
2-8=-251/160
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=S.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left exposed ; porch left exposed; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
5) . This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
2x4 II 2x4 II
CSI.
DEFL. in
(loc)
I/defl
Ud
TC 0.13
Vert(LL) -0.00
7
>999
360
BC 0.12
Vert(CT) -0.00
6-7
>999
240
WB 0.04
Horz(CT) -0.01
5 ,
n/a
n/a
Matrix -MP
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 112 lb uplift at
joint 5, 373 lb uplift at joint 8 and 584 lb uplift at joint '7.
8) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 293
lb down and 418 lb up at 3-8-0 on top chord, and 253
lb down and 363 Ib'up at 3-8-0 on bottom chord. The
design/selection of such connection device(s) is the
responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (pig
Vert: 1-3=-90, 3-4=-90, 4-5=-90, 6-9=-20
Concentrated Loads (lb)
Vert: 3=184(B) 7=191(B)
m
N
PLATES GRIP
MT20 244/190
Weight: 39 lb FT = 10%
Job
Truss
Truss Type
Qty
Ply
A0117242
72005
D02
Jack -Open
4
1
t
Job Reference (optional)
_ _. -_ _ �.
.... .. ... ... . ....__
1
0
4nI .. AI....
40 nnA7 FA;Ti LL In A,. -riot Inn Tl— RA— 1 n0•15•9.9 7n1A Pena 1
Al Koor Trusses, Pori Pierce, FL 34946, aesigngua iuuss.wm
�. �c., s .-- cv.......... ....... ....... ...... .........-Y _ _-.._.__ _,.._ ... _ .
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-ASMBdGFXAo_QmNf WmOJkBxKBoCQGrBcGKBpJHrzKGVq
0- -0
4-1-8
5-8-0 7-0-0
0- -6
4-1-8
1-6-8 1-4-0
4x4 =
4 5
5.00 12
3x811 T2
3
2x4 11
2
1
O
� N
W2
n
1
B1
E L•
L• A•
3x4
= 8
7 g
2x4 11
2x4 11
1-9-8 2-1-0
4-1-8 5-a-0 - _I 6-8-8 7,-0-p
1-9-8 -4-
1 2-0-0 1-6-8 1-0-8 0-3-8
Plate Offsets (X Y)— [4.0-2-0 0-0-111
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft
Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.28
Vert(LL) 0.00 7-8 >999
360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.25
Vert(CT) 0.00 7-8 >999
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.10
Horz(CT) -0.01 5 n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 39 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
5) ` This truss has been designed for a live load of
BOT CHORD 2x6 SP No.2
20.Opsf on the bottom chord in all areas where a
WEBS 2x6 SP No.2
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
BRACING-
bottom chord and any other members.
ORD
6) Refer to girder(s), for truss to truss connections.
Structural wood sheathing directly applied or 6-0-0 oc
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
BOT CHORD
joint(s) 5 except (jt= b) 8=294, 7=356.
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
LOAD CASE(S)
accordance with Stabilizer Installation quide. I
Standard
REACTIONS. All bearings Mechanical except Qt=length)
8=0-8-0, 7=0-8-0.
(lb) - Max Horz
8= 214(LC 12)
Max Uplift
All uplift 100 lb or less atjoint(s)
5 except 8=-294(LC 8), 7=-356(LC 9)
Max Grav
All reactions 250 lb or less at joint(s)
5, 6 except 8=386(LC 1), 7=290(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-391/140, 2-3=-271/123
BOT CHORD
1-8=-157/437
WEBS
1
2-8=-153/298, 3-7=-411/775
;
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; VuIt=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf, BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ; porch
left exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
Job
Truss
Truss Type
qt
Qty
ply
72005
EB01
MONOIPITCH
1
A0117243
Job Reference (optional)
rvn i cn uiuusuros, mu. i nu may a ua:-io:o4 zuia rage i
7YIAE
ID:nKMLCG99vHyLG9D5X 3P-eewagcG9w66HOXEiJ5rzk8tPUcnFacMPYrYtpHzKGVp
0 q-6 1-8-0
0- 1-8-0
5.00 12 2
3x4 = 3
1-10-8
30 II
1-8-0
1-4-8
1-8-
1-4-8
2
0-1-8
Plate Offsets (X,Y)--
12:0-4-4,0-1-81 f3:0-2-8 0-1-8]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/defl
L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.09
Vert(LL)
0.00 6
n/r
90
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.13
Vert(CT)
-0.00 6
n/r
80
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT)
0.00
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 9 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 1-8-0 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
171/Mechanical
2 =
-0/Mechanical
Max Horz
3 =
191(LC 8)
2 =
178(LC 1)
Max Uplift
3 =
-165(LC 8)
Max Grav
3 =
171(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-591/208, 2-3=-121/348
BOT CHORD
1-3=-178/618
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ; porch
left exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except Qt=1b) 3=165.
7) Gap between inside of top chord bearing and first
'diagonal or vertical web shall not exceed 0.500in.
I
LOAD CASE(S)
Standard
Job
Truss
Truss Type I
Qty
Ply
A0117244
72005
EB02
ROOF SPECIAL GIRDER
4
1
f
Job Reference (optional)
Al Koot I russes, tort Fierce, rl_ 34ti4o, oesign(Q/,a-i truss.com
LOADING (psf) SPACING- 2-0-0
TCLL 30.0 Plate Grip DOL 1.25
TCDL 15.0 Lumber DOL 1.25
BCLL 0.0 Rep Stress Incr NO
BCDL 10.0 Code FBC2017/TPI2014
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-3-9 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 = 0/Mechanical
3 = 424/Mechanical
Max Horz
2 = 589(LC 1)
3 =-589(LC 1)
Max Uplift
3 =-396(LC 4)
Max Grav
3 = 424(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-585/647, 2-3=-299/275
BOT CHORD
1-3=-589/585
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left exposed ; porch left exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Refer to girder(s) for truss to truss connections.
o. .I- - -, ".- " U."
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-6gUy2yGnhPE7?hovtpMCHMQZw?72J3'. nVIQMkzKGVo
3.54 F12 2
3x6
T1 W1
81
I
3M = 3
3x6 11
2-3-9
CSI. DEFL. in (loc) I/deft Ud
TC 0.18 Vert(LL) 0.00 6 n/r 90
BC 0.16 Vert(CT) -0.00 6 n/r 8C
WB 0.00 Horz(CT) 0.00 n/a n/a
Matrix -MP
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except (jt=6U) 3=396.
7) Gap between inside of top chord bearing and first
diagonal or vertical web shall not exceed 0.500in.
8) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 91
lb down and 129 lb up at 1-5-0, and 91 lb down and
129 lb up at 1-5-0 on bottom chord. The
design/selection of such connection device(s) is the
responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Lives (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-90, 3-4=-20
Concentrated Loads (lb)
Vert: 6=-181(F=-i1, B=-91)
PLATES GRIP
MT20 244/190
Weight: 12 lb FT = 10%
Job
Truss
Truss Ty
Qty
Ply
ie
A0117245
72005
G01G
Hip Girder
1
1
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, 0esignLa11russ.c0m
7x10 II
2x4
G4 L.7
6x8 =
O. I Lu S im— , G GV , luuz ,ca a w. , uu ,.,oy a v.a. , —I— .
VLG9D5?YIAEyzKd3P-2DbiTel2D1 UrF_rH?DOgMnVgxpl_npMrEpnXQczKGVr
-10-0 22-10-0 22-� 0-3
s n 7-0-0 0-1-3
2x4 II
Dead Load Defl. =1116 in
7x10 II
1-10-8 28 7-0-0 11-5-0 15-10-0 20-7-8 2 14 822-6-82 1 -0
1-10-8 �l-0 4-9-8 4 5-0 4-5-0 4-9 8 4-0 1-7-0 0-3-8
n r 44 n n n G.A n e .Al rn •n_r;-n n- -Ai rr -n-n_1 9_1_ 31 m-n_r-11 n-n-71 r7•n-d-n n-4-At
r1a vuaEl 1
LOADING (psf)
_
SPACING-
2-0-0
I_
CSI.
_ _ _ - - _
DEFL. in
(loc)
I/defl
L/d
PLATES
GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.47
Vert(LL) 0.34
7
>811
360
MT20
244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.39
Vert(CT) 0.31
7
>885
240
MT20HS
187/143
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.69
Horz(CT) -0.06
5
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 130 Ib
FT = 10%
LUMBER -
TOP CHORD 2x6 SP 240OF 2.0E
BOT CHORD 2x6 SP 240OF 2.0E
WEBS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3,
Right: 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-1-9 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 4-9-11 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (Ib/size)
1 =
1556/0-8-0 (min.0-1-8)
5 =
155610-8-0 (min. 0-1-8)
Max Horz
1 =
58(LC 34)
Max Uplift
1 =
-2178(LC 4)
5 =
-2045(LC 4)
Max Grav
1 =
1556(LC 1)
5 =
1556(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-2910/4339, 2-19=-3839/5750,
19-20=-3839/5750, 3-20=-3839/5750,
3-21=-3839/5750, 21-22=-3839/5750,
4-22=-3839/5750, 4-5=-2910/4294
BOT CHORD
1-8=-4086/2741, 8-23=-4091 /2725,
23-24=-4091/2725, 7-24=-4091/2725,
7-25=-4033/2725, 25-26=-4033/2725,
6-26=-4033/2725, 5-6=-4028/2741
WEBS
2-7=-1674/1272, 3-7=-748/735,
4-7=-1737/1272
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft-,
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; porch left exposed;
Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) All plates are MT20 plates unless otherwise
indicated.
5) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
6)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except at=lb) 1=2178, 5=2045.
8) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 245
lb down and 376 lb up at 7-0-0, 111 lb down and 184
lb up at 9-0-12, 111 lb down and 184 lb up at 11-0-12
, 111 lb down and 184 lb up at 11-9-4, and 111 Ib
down and 184 lb up at 13-9-4, and 245 lb down and
376 lb up at 15-10-0 on top chord, and 357 lb down
and 329 lb up at 7-0-0, 91 lb down and 132 lb up at
9-0-12, 91 lb down and 132 lb up at 11-0-12, 91 lb
down and 132 lb up at 11-9-4, and 91 lb down and
132 lb up at 13-9-4, and 357 lb down and 329 lb up at
15-9-4 on bottom chord. The design/selection of such
connection device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-90, 2-4=-90, 4-5=-90, 9-14=-20
Concentrated Loads (lb)
Standard
Vert: 2=-174(F) 4=-174(F) 8=67(F) 6=67(F)
19=-93(F)20=-93(F)21=-93(F)22=-93(F) 23=-2(F)
24=-2(F) 25=-2(F) 26=-2(F)
Job
Truss
Truss Type
Qty
Ply
A0117246
72005
G02
Hip
1
1
Job Reference o tional
Al goof Trusses, Fort Pierce, FL 34946, design@altruss.com
9-0-0
5x6 11
3.00 F12
8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:15:58 2018
5x6 It
0-0
Dead Load Defl. = 1/16 in
8x10 11 2x4 11 14x6 = 2x4 11 8x10 11 . 4x10 =
1-10-8 2r2�8 9-0-0 13-10-0 20-7-8 20r1j-822-6-822rl"
1-10-8 4-0 6-9-8 4-10-0 6-9-8-0 1-7-0 01318
Plate Offsets (X,Y)-- [1:0-1-15,Edge), [2:0-4-4,0-2-8), [3:0-4-4,0-2-8), [4:0-1-15,Edge)
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc)
I/defl
L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.81
Vert(LL) 0.25
5-7
>999
360
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.63
Vert(CT) 0.23
5-7
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.10
Horz(CT) -0.06
4
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 118 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP 240OF 2.OE *Except`
T2: 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3,
Right: 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-0-0 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or 3-0-4 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation ouide.
REACTIONS. (lb/size)
1 = 1258/0-8-0 (min. 0-1-8)
4 = 1258/0-8-0 (min. 0-1-8)
Max Horz
1 = 74(LC 12)
Max Uplift
1 =-1459(LC 8)
4 =-1296(LC 8)
Max Grav
1 = 1258(LC 1)
4 = 1258(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-2075/4921,2-3=-1933/4883,
3-4=-2075/4921
BOT CHORD
1-7=-4523/1929, 6-7=-4562/1933,
5-6=-4562/1933, 4-5=-4523/1929
WEBS
2-7=-631/183, 3-5=-631/183
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. 11; Exp D; Encl 1, GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2)Izone; cantilever left and right
exposed; porch left, exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding. 1
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall dy 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except Qt=1b)I 1=1459, 4=1296.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
72005
G03
Common
1
1
A0117247
Job Reference (optional)
�_ . ���:y :� a .: ���•u, �: rf.12u s Nov 12 201 t MI I ek Industries, Inc. Thu May 3 09:15:59 2018
I D:nKMLCG99vHyLG9D5?YIAEyzKd3P-_cjTtJJ11eIZU16g6eQ8RCaB5dOCFg28i7Ge\j
0-3
0: 10-0
5x10 MT20HS=
3.00 F12
7x10 11 7x6 5x10 =
=
7x10 II
1-10-8 2 8 11-5-0 20-7-8 2Q 11-822 6 22r1p-0
-u 9-2-8 9-2-8 �_n _ nnA
Plate Offsets (X,Y)—
[1:0-1-1 1,Edge] [1:0-0-1 2-1-31
[3:0-0-1 2-1-31
[3.0-1-11 Edge]
[4.0-3-0 0-5-01
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in
(loc)
I/deft
L/d
PLATES
GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC
0.42
Vert(LL) 0.23
4-9
>999
360
MT20
244/190
TCDL 15.0
Lumber DOL 1.25
BC
0.60
Vert(CT) 0.21
4-9
>999
240
MT20HS
187/143
BCLL 0.0
Rep Stress Incr YES
WB
0.23
Horz(CT) -0.06
3
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 116 Ib
FT = 10%
LUMBER -
TOP CHORD 2x6 SP 240OF 2.0E
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No:3
WEDGE
Left: 2x4 SP No.3,
Right: 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 2-11-14 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 =
1258/0-8-0 (min. 0-1-8)
3 =
125810-8-0 (min. 0-1-8)
Max Horz
1 =
92(LC 12)
Max Uplift
1 =
-1430(LC 8)
3 =
-1262(LC 8)
Max Grav
1 =
1258(LC 1)
3 =
1258(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-1961/4734, 2-3=-1961/4734
BOT CHORD
1-4=-4327/1807, 3-4=-4327/1807
WEBS
2-4=-1201/342
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf, BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; porch left exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise
indicated.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) ' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
i joint(s) except (jt=1b) 1=1430, 3=1262.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
A0117248
72005
G04
Common
1
1
*
Job Reference (optional)
Al Koor i russes, ror[ rierce, r.L xa4o, ueslyiiLe 1 u uss.wu
0-0-0 11-5-0
3.00 FIT
ID:nKMLCG99vH;LG9D5?YIAEyzKd3P-_cjTtJJ IIeIZU I6g6eQ8RCaBAdO? Fg08i7GeWzKGVk
99-in-n 99-1n-9
6x6 =
2
1
I
1
5x10 = se ;
4
e t
5x10 MT20HSII
7x6 =
5x10 =
5x10 MT20HSII
1-10 8 2 8
11-5-0 20-7-8
2 1-822-6-822 1
1-10-8 4-0
9-2-8 9-2-8
_4 1-7-0 0-3-
Plate Offsets (X Y)— [1.0-0-5 2-2-3] [1.0-1-11 Edge]
[2.0-3-0 0-4-0] [3.0-1-11
Edgel [3:0-0-5 2-2-3] 4:0-3-0 0-5-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.42
Vert(LL) 0.23 4-9 >999 360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.61
Vert(CT) 0.21 4-9 >999 240
MT20HS 187/143
BCLL 0.0 '
Rep Stress Incr YES
WB 0.23
Horz(CT) -0.06 3 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 116 Ib FT = 10%
LUMBER -
TOP CHORD 2x6 SP 2400E 2.0E
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
BOT CHORD 2x6 SP No.2
Vasd=139mph; TCDL=5.Opsf, BCDL=5.Opsf; h=39ft;
WEBS 2x4 SP No.3
Cat. II; Exp D; Encl 1, GCpi=0.18; MWFRS (envelope)
WEDGE
and C-C Exterior(2)Izone; cantilever left and right
Left: 2x4 SP No.3,
exposed ; porch left, exposed;C-C for members and
Right: 2x4 SP No.3
forces &MWFRS far reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
TOP CHORD
All plates are MT20 plates unless otherwise
All
Structural wood sheathing directly applied or 6-0-0 oc
i
in
n
puriins.
4) This truss has been designed for a 10.0 psf bottom
BOTCHRigid
chord live load nonconcurrent with any other live
ceilliRD ing directly applied or 3-0-4 oc bracing.
loads.
MiTek recommends that Stabilizers and required
5) ` This truss has been designed for a live load of
cross bracing be installed during truss erection, in
20.Opsf on the bottom chord in all areas where a
accordance with Stabilizer Installation guide.
rectangle 3-6-0 tall dy 2-0-0 wide will fit between the
bottom chord and any other members.
REACTIONS. (lb/size)
6) Provide mechanical connection (by others) of truss
1 = 1258/0-8-0 (min. 0-1-8)
to bearing plate capable of withstanding 100 lb uplift at
3 = 1258/0-8-0 (min. 0-1-8)
joint(s) except (jt=1b) 1=1429, 3=1262.
Max Horz
i
1 = 94(LC 12)
Max Uplift
LOAD CASE(S)
1 =-1429(LC 8)
Standard
3 =-1262(LC 8)
Max Grav
1 = 1258(LC 1)
3 = 1258(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2==,-1937/4670, 2-3=-1937/4670
BOT CHORD
1-4=-4256/1779, 3-4=-4256/1779
WEBS
2-4=-1212/345
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
I
Io
Job
Truss
Truss Type
Qty
Ply
72005
G05
COMMON
3
1
AO117249
Job Reference (optional)
v. j cv a iwv is u i i mi J eK 111uUSLnes, mu. i nu may a uu:l o:uu zuit5 rage i
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-SoHrSfKwWytQ6ShsgMxNzP7EB0ic_7SIxn?B1 xzKGVj
19-4-8 ;a
5x6 11
2
6x10 11 7x8 = 4x8 11
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deli
Ud
TCLL 30.0
Plate Grip DOL
1.25
TC 0.91
Vert(LL)
0.26
5-10
>889
360
TCDL 15.0
Lumber DOL
1.25
BC 0.65
Vert(CT)
0.23
5-10
>978
240
BCLL 0.0 '
Rep Stress Incr
YES
i WB 0.86
Horz(CT)
-0.03
4
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
LUMBER -
TOP CHORD 2x6 SP 2400F 2.0E 'Except`
T2: 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
W3: 2x8 SP 2400F 1.8E
WEDGE
Left: 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
pur ins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 2-11-12 oc bracing.
WEBS
1 Row at midpt 3-5
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
4 =
934/Mechanical
1 =
1165/0-8-0 (min. 0-1-8)
Max Horz
1 =
148(LC 12)
Max Uplift
4 =
-964(LC 8)
1 =
-1333(LC 8)
Max Grav
4 =
934(LC 1)
1 =
1165(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-1624/4040, 2-3=-1609/4055,
3-4=-858/1865
BOT CHORD
1-5=-3785/1478, 4-5=-1018/417
WEBS
2-5=-919/249, 3-5=-2791/1070
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=S.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;
porch left exposed;C-C for members and forces $
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
4) ' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except (jt=1b) 4=964, 1=1333.
LOAD CASE(S)
Standard
PLATES
MT20
GRIP
244/190
Weight: 111 Ib FT = 10%
I-,
Job
Truss
Truss Type
Qty
Ply
1
A0117250
72005
G06G
COMMON
1
1
r
I
IJob
Reference (optional)
Al Rbof Trusses, Fort Pierce, FL 34946, design@altruss.com
11-5-0
8.120 s Nov 12 2017 MI l ek industries, Inc. Thu May 3 14:12:03 20i 8 rage 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-s65_9SI1 Jdp3fE7mlP7sPGJu80GBOt2rXsNd_tzKCAA
6x6 =
7-11-8
7x10 11 17x6 = 3x10 11
1-10-8 1
11-5-0
i
1-10-8
9-6-8
Plate Offsets (X Y)— [1:0-0-1 2-1-3] [1:0-5-11 Edge] [3:0-3-1 0-1-9L[4:0-5-4,0}1-8],[5:0-2-12,0-4-81
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Ud
TCLL 30.0
Plate Grip DOL 1.25
TC 0.55
Vert(LL) 0.17 5-10 >999 360
TCDL 15.0
Lumber DOL 1.25
BC 0.40
Vert(CT) 0.15 5-10 >999 240
BCLL 0.0
Rep Stress Incr NO
WB 0.40
Horz(CT) -0.02 4 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
LUMBER -
TOP CHORD 2x6 SP 2400E 2.0E *Except*
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
T2: 2x6 SP No.2
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
BOT CHORD 2x6 SP No.2
'Except`
Cat. 11; Exp D; Enclj, GCpi=0.18; MWFRS (envelope);
WEBS 2x4 SP No.3
cantilever left exposed ; porch left exposed; Lumber
W3: 2x8 SP 240OF 1.8E
DOL=1.60 plate grip DOL=1.60
WEDGE
3) This truss has been designed for a 10.0 psf bottom
Left: 2x4 SP No.3
chord live load nonconcurrent with any other live
BRACING-
loads.
TOP CHORD
Structural wood sheathing directly applied or 4-11-11 oc
4) This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
purlins, except end verticals.
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
BOT CHORD
bottom chord and any other members.
Rigid ceiling directly applied or 5-5-12 oc bracing.
5) Refer to girder(s)for truss to truss connections.
WEBS
1 Row at midpt 3-5
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 961 lb uplift at
MiTek recommends that Stabilizers and required
joint 4 and 1283 lb uplift at joint 1.
cross bracing be installed during truss erection, in
7) Hanger(s) or other connection device(s) shall be
accordance with Stabilizer Installation guide.
provided sufficient to support concentrated load(s) 287
lb down and 299 lb up at 2-7-8 on top chord. The
REACTIONS. (lb/size)
design/selection of such connection device(s) is the
4 = 929/Mechanical
responsibility of others.
1 = 1058/0-8-0 (min. 0-1-8)
8) In the LOAD CASES) section, loads applied to the
Max Horz
face of the truss are noted as front (F) or back (B).
1 = 148(LC 8)
Max Uplift
4 =-961(LC 4)
LOAD CASE(S)
1 =-1283(LC 4)
Standard
Max Grav
1) Dead + Roof Livej(balanced): Lumber Increase=1.25
4 = 929(LC 1)
, Plate Increase=1.25
1 = 1058(LC 1)
Uniform Loads (plf)
Vert: 1-2=-90, 2-3� -90, 4-6=-20
FORCES. (lb)
Concentrated Loads (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
Vert: 9=113(B)
when shown.
TOP CHORD
1-2=-1 603/1708, 2-3=-1 586/1739,
3-4=-851 /785
BOT CHORD
1-5=-1618/1456, 4-5=-391/425
WEBS
2-5=-298/245, 3-5=-1244/1045
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
1
19-4-8
7-11-8
PLATES GRIP
MT20 244/190
Weight: 111 Ib FT = 10%
Job
Truss
Truss Type
Qty
Ply
72005
HC3
RAFTER TRUSS
4
1
A0117251
1
Job Reference (optional)
Hi Koor i russes, rorr rierce, rL 34v4o, ceslgnLaitruss.com 1 mizu s Nov lz zul / MI I eK rnausines, inc. i nu May s uV:ib:ui zui b rage 9
I D:?V729FIbgDtORu3?XJcch4zsTYu-x_rDI?LYHF?H kcG3E3TcWdgZoQCzjn5R9R!,kZNzKG Vi
2-9-5
2-9-5
2.12 F12
2
h
T
0
T1
0
o
2-9-5
2-9-5
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc)
I/deli
Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.28
Vert(LL) 0.02
1-2
>999
360
TCDL 15.0
Lumber DOL 1.25
BC 0.00
Vert(CT) 0.02
1-2
>999
240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
2
n/a
n/a
BCDL 10.0
Code FBC2017(rP12014
Matrix -MP
Weight: 4 lb FT = 0%
LUMBER -
TOP CHORD 2x4 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-9-5 oc
purlins.
BOT CHORD
Rigid ceiling directly applied.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 = 119/Mechanical
2 = 119/Mechanical
Max Horz
1 = 42(LC 8)
Max Uplift
1 =-102(LC 8)
2 =-109(LC 8)
Max Grav
1 = 119(LC 1)
2 = 119(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf, BCDL=5.Opsf, h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) . This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 100 lb uplift at
joint(s) except (jt=lb) 1=102, 2=109.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
�52
AO117252
72005
HC5
RAFTER TRUSS
1
Job Reference (optional)
Al KOOr I russes, ron Yrerce, rL 69a'io, oCsIgnLa i u Ub-1.1
ID:lnl El4n4krFMR5vCX81ws4z20vo-x_rDI?LYHF?HkcG3E3TcWdgZVQCzjn5R9RlkZNzKGVi
2-9-5
3.54 F12
2
I
T1
n
0
2-9-5
2-9-5
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
TCLL
30.0
Plate Grip DOL
1.25
TC 0.30
Vert(LL)
-0.01
1-2
>999
360
TCDL
15.0
Lumber DOL
1.25
BC 0.00
Vert(CT)'
-0.01
1-2
>999
240
BCLL
0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
2
n/a
n/a
BCDL
10.0
Code FBC20171TP12014
Matrix -MP
Wind(LL)
0.02
1-2
>999
240
Weight: 4 lb FT = 20%
LUMBER -
TOP CHORD 2x4 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-9-5 oc
pudins.
BOT CHORD
Rigid ceiling directly applied.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 =
119/Mechanical
2 =
119/Mechanical
Max Horz
1 =
70(LC 8)
Max Uplift
1 =
-95(LC 8)
2 =
-116(LC 8)
Max Grav
1 =
119(LC 1)
2 =
119(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 100 lb uplift at
joint(s) 1 except Qt=lb) 2=116.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
72005
HJ5
Diagonal Hip Girder
2
1
A0117255
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com 8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:16:02 2018 Page 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-PBPbWLMA2Z78LIrFnn_r3gCgMq(ITSEXaOSU 15gzKGVh
-O,P-8 7-0-2 r
0 -8 7-0-2
3x6 11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.55
Vert(LL) -0.03
4-5
>999
360
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.56
Vert(CT) 0.04
4-5
>999
240
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.05
Horz(CT) -0.06
3
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
j Matrix -MP
Weight: 36 lb FT = 10%
11110 13
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
1/Mechanical
4 =
-121/Mechanical
5 =
671/0-11-5 (min. 0-1-8)
Max Horz
5 =
403(LC 4)
Max Uplift
3 =
-92(LC 4)
4 =
-162(LC 19)
5 =
-746(LC 8)
Max Grav
3 =
66(LC 35)
4 =
97(LC 22)
5 =
786(LC 35)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
BOT CHORD
1-5=0/403
WEBS
2-5=-480/415
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=S.Opsf; BCDL=S.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left exposed ; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) . This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
88�gRb6�%j pd&2y other members
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
,to bearing plate capable of withstanding 100 lb uplift at
Ijoint(s) 3 except (jt=lb) 4=162, 5=746.
,6) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13,
114, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27,
28, 29, 30, 31, 32, 33, 34, 35 has/have been modified.
Building designer must review loads to verify that they
are correct for the intended use of this truss.
7) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 109
i lb left at 1-5-0, 109 lb left at 1-5-0, and 192 lb down
and 236 lb up at 4-2-15, and 192 lb down and 236 lb
up at 4-2-15 on top chord, and 84 lb down and 129 lb
up at 1-5-0, 84 lb down and 129 lb up at 1-5-0, and
99 lb down and 190 lb up at 4-2-15, and 99 lb down
and 190 lb up at 4-2-15 on bottom chord. The
design/selection of such connection device(s) is the
responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-90, 4-6=-20
Concentrated Loads (lb)
Vert: 8=-168(F=-84, B=-84) 9=190(F=95, B=95)
10=197(F=99,B=99)
Horz: 7=-218(F=-109, B=-109)
2) Dead + 0.75 Roof Live (balanced): Lumber
Increase=1.25, Plate Increase=1.25
Uniform Loads (pig
Vert: 1-3=-75, 4-6=-20
Concentrated Loads (lb)
Vert: 8=-137(F=-69, B=-69) 9=190(F=95, B=95)
1 0=1 97(F=99, B=99)
Horz: 7=-218(F=-109, B=-109)
3) Dead + Uninhabitable Attic Without Storage: Lumber
Increase=1.25, Plate Increase=1.25
Uniform Loads (pig
Vert: 1-3=-30, 4-6=-40
Concentrated Loads (lb)
Standard
Vert: 8=-45(F=-23, B=-23) 9=190(F=95, B=95)
10=197(F=99,B=99)
Horz: 7=-218(F=-109, B=-109)
4) Dead + 0.6 MWFRS Wind (Pos. Internal) Left:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=80, 5-6=51, 4-5=-10
Horz: 1-3=-90
Concentrated Loads (Ib)
Vert: 8=72(F=36, B=36) 9=-90(F=-45, B=45)
10=167(F=83,B=83)
Horz: 7=-218(F=-109, B=-109)
5) Dead + 0.6 MWFRS Wind (Pos. Internal) Right:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=55, 4-6=-10
Horz: 1-3=-65
Concentrated Loads (lb)
Vert: 8=246(F=123, B=123) 9=-22(F=-11, B=-11)
10=171(F=85,B=85)
Horz: 7=-218(F=-109, B=-109)
6) Dead + 0.6 MWFRS Wind (Neg. Intemal) Left:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pin
Vert: 1-3=22, 5-6=41, 4-5=-20
Horz: 1-3=-52
Concentrated Loads (lb)
Vert: 8=85(F=42, B=42) 9=33(F=17, B=17)
10=195(F=98,B=98)
Horz: 7=-218(F=-109, B=-109)
7) Dead + 0.6 MWFRS Wind (Neg. Internal) Right:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=-2, 4-6=-20
Horz: 1-3=-28
Concentrated Loads (lb)
Vert: 8=258(F=129, B=129) 9=102(F=51, B=51)
10=199(F=99,B=99) ,
Horz: 7=-218(F=-109, B=-109)
8) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st
Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pig
Vert: 1-3=80, 4-6=-10
Horz: 1-3=-90
Job
Truss
Truss Type
Qty
Ply
A0117255
72005
HJ5
Diagonal Hip Girder
2
1
r
Job Reference o tional
Al Root I fusses, tort fierce, t-L 34u4t), cesignLa i uuss.corn
LOAD CASE(S)
Standard
Concentrated Loads (lb)
Vert: 8=246(F=123, B=123) 9=-90(F=-45, B=-45)
10=171(F=85, B=85)
Horz: 7=-218(F=-109, B=-109)
9) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=47, 4-6=-10
Horz: 1-3=-57
Concentrated Loads (lb)
Vert: 8=246(17=123, B=123) 9=3(F=1, B=1)
10=171(F=85, B=85)
Horz: 7=-218(F=-109, B=-109)
10) Dead + 0.6 MWFRS Wind (Pos. Internal) 3rd
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=80, 4-6=-10
Horz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=246(F=123, B=123) 9=-90(F=-45, B=-45)
10=171(F=85, B=85)
Horz: 7=-218(F=-109, B=-109)
11) Dead + 0.6 MWFRS Wind (Pos. Internal) 4th
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=47, 4-6=-10
Horz: 1-3=-57
Concentrated Loads (lb)
Vert: 8=246(F=123, B=123) 9=3(F=1, B=1)
10=171(F=85, B=85)
Horz: 7=-218(F=-109, B=-109)
12) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=22, 4-6=-20
Horz: 1-3=-52
Concentrated Loads (lb)
Vert: 8=258(F=129, B=129) 9=33(F=17, 13=17)
10=199(F=99, B=99)
Horz: 7=-218(F=-109, B=-109)
13) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plo
Vert: 1-3=-10, 4-6=-20
Horz: 1-3=-20
Concentrated Loads (lb)
Vert: 8=258(F=129, B=129) 9=126(F=63, 13=63)
1 0=1 99(F=99, B=99)
Horz: 7=-218(F=-109, B=-109)
14) Dead: Lumber Increase=0.90, Plate Increase=0.90
Pit. metal=0.90
Uniform Loads (pin
Vert: 1-3=-30, 4-6=-20
Concentrated Loads (lb)
Vert: 8=-45(F=-23, B=-23) 9=190(F=95, 13=95)
10=197(F=99, B=99)
Horz: 7=-218(F=-109, B=-109)
15) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int) Left): Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pig
Vert: 1-3=-36, 5-6=26, 4-5=-20
Horz: 1-3=-39
Concentrated Loads (lb)
Vert: 8=64(F=32, B=32) 9=262(F=131, B=131)
10=298(F=149,E=149)
Horz: 7=-218(F=-109, B=-109)
16) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int) Right): Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pin
Vert: 1-3=-54, 4-6=-20
Horz: 1-3=-21
Concentrated Loads (lb)
Continued on page 3
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-PBPbW LMA2Z78LIrFnn_r3gCgMgQTSEXaO5U l5gzKGVh
Standard
Vert: 8=193(F=97, B=97) 9=314(F=157, B=157)
10=301(F=15 j, B=151)
Horz: 7=-218( =-109, B=-109)
17) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int)1st Parallel): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=-36, 4-6=-20
Horz: 1-3=-39I
Concentrated Loads (lb)
Vert. 8=193(F=97, 13=97) 9=262(F=131, B=131)
10=301(F=15 1, B=151)
Horz: 7=-218(F=-109, B=-109)
18) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int) 2nd Parallel): Lumber
Increase=1.60 Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=-60, 4-6=-20
Horz: 1-3=-15
Concentrated -oads (lb)
Vert: 8=193(F 97, B=97) 9=332(F=166, B=166)
1 0=301 (F=1 51', B=151)
Horz: 7=-218(F=-109, B=-109)
19) Reversal: Dead + Roof Live (balanced): Lumber
Increase=1.25i Plate Increase=1.25
Uniform Loads (pig
Vert: 1-3=-90, 4-6=-20
Concentrated Loads (lb)
Vert: 8=-45(F=L 23, B=-23) 9=471(F=236, B=236)
10=380(F=190,, B=190)
Horz: 7=-218(F=-109, B=-109)
20) Reversal: Dead + 0.75 Roof Live (balanced):
Lumber Increase=1.25, Plate Increase=1.25
Uniform Loadsl (pig
Vert: 1-3=-75, 4-6=-20
Concentrated 1�1 oads (lb)
Vert. 8=-45(F=i 23, B=-23) 9=401(F=200, B=200)
10=334(F=167!,B=167)
Horz: 7=-218(F=-109, B=-109)
21) Reversal: Dead: Lumber Increase=0.90, Plate
Increase=0.90 Pit. metal=0.90
Uniform Loadsl(plf)
Vert: 1-3=-30, 4-6=-20
Concentrated lioads (lb)
Vert: 8= 45(F= 23, B=-23) 9=190(F=95, B=95)
10=197(F=99, P=99)
Horz: 7=-218(P=-109, B=-109)
22) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
Left: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loadsl(plo
Vert: 1-3=80, 5-6=51, 4-5=-10
Horz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=-111(F -56, B=-56) 9=-383(F=-192,
B=-192) 10=-198(F=-99, B=-99)
Horz: 7=-218(F� -109, B=-109)
23) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
Right: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=55, 4-6=-10
Horz: 1-3=-65
Concentrated Loads (lb)
Vert: 8=-53(F= 27, B=-27) 9=-315(F=-157, B=-157)
10=-194(F=-97; B=-97)
Horz: 7=-218(FL -109, B=-109)
24) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
Left: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=22, 5216=41, 4-5=-20
Horz:1-3=-52 i
Concentrated Loads (lb)
Vert: 8=-83(F=-42, B=-42) 9=-260(F=-130, B=-130)
10=-170(F=-85,11 B=-85)
Horz: 7=-218(F=-109, B=-109)
25) Reversal: Deadl+ 0.6 MWFRS Wind (Neg. Internal)
Right: Lumber I crease=1.60, Plate Increase=1.60
Standard
Uniform Loads (pig
Vert: 1-3=-2, 4-6=-20
Horz: 1-3=-28
Concentrated Loads (lb)
Vert: 8=-25(F=-12, B=-12) 9=-1 91 (F=-95, B=-95)
10=-166(F=-83, B=-83)
Horz: 7=-218(F=-109, B=-109)
26) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
1st Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pig
Vert: 1-3=80, 4-6=-10
Horz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-383(F=-192, B=-192)
10=-194(F=-97, B=-97)
Horz: 7=-218(F=-109, B=-109)
27) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
2nd Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pig
Vert: 1-3=47, 4-6=-10
Horz: 1-3=-57
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-290(F=-145, B=-145)
10=-194(F=-97, B=-97)
Horz: 7=-218(F=-109, B=-109)
28) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
3rd Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pig
Vert: 1-3=80, 4-6=-10
Horz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-383(F=-192, B=-192)
10=-194(F=-97, B=-97)
Horz: 7=-218(F=-109, B=-109)
29) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
4th Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plo
Vert: 1-3=47, 4-6=-10
Horz: 1-3=-57
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-290(F=-145, B=-145)
10=-194(F=-97, B=-97)
Horz: 7=-218(F=-109, B=-109)
30) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
1st Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pig
Vert: 1-3=22, 4-6=-20
Horz: 1-3=-52
Concentrated Loads (lb)
Vert: 8=-25(F=-12, B=-12) 9=-260(F=-130, B=-130)
10=-166(F=-83, B=-83)
Horz: 7=-218(F=-109, B=-109)
31) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
2nd Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pig
Vert: 1-3=-10, 4-6=-20
Horz: 1-3=-20
Concentrated Loads (lb)
Vert: 8=-25(F=-12, B=-12) 9=-167(F=-83, B=-83)
10=-166(F=-83, B=-83)
Horz: 7=-218(F=-109, B=-109)
32) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) Left): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=-36, 5-6=26, 4-5=-20
Horz: 1-3=-39
Concentrated Loads (lb)
Job
Truss
Truss Type
Qty
Ply
72005
HJ5
Diagonal Hip Girder
2
1
A0117255
Job Reference (optional)
uabcb, rui i rro� cc, FL J vC u, uebiynLd i uuss.wrn t$.l ZU S NOV 1Z ZU1 / MI I eK Industries, Inc. Thu May 3 0 .16:02 2018 Page 3
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-PBPbWLMA2Z78LIrFnn_r3gCgMgQ SEXaO5U15gzKGVh
LOAD CASE(S)
Standard
Concentrated Loads (lb)
Vert: 8=-142(F=-71, B=-71) 9=-163(F=-81, B=-81)
10=-99(F=-50, B=-50)
Horz: 7=-218(F=-109, B=-109)
33) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) Right): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-54, 4-6=-20
Horz: 1-3=-21
Concentrated Loads (lb)
Vert: 8=-99(F=-49, B=49) 9=-111(F=-56, B=-56)
10=-96(F=-48, B=-48)
Horz: 7=-218(F=-109, B=-109)
34) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) 1st Parallel): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (plo
Vert: 1-3=-36, 4-6=-20
Horz: 1-3=-39
Concentrated Loads (lb)
Vert: 8=-99(F=-49, B=-49) 9=-163(F=-81, B=-81)
10=-96(F=-48, B=-48)
Horz: 7=-218(F=-109, B=-109)
35) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) 2nd Parallel): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (plo
Vert: 1-3=-60, 4-6=-20
Horz: 1-3=-15
Concentrated Loads (lb)
Vert: 8=-99(F=-49, B=-49) 9=-93(F=-46, B=-46)
10=-96(F=-48, B=-48)
Horz: 7=-218(F=-109, B=-109)
Job
Truss
Truss Type
Qty
Ply
A0117256
72005
HJ5A
Diagonal Hip Girder
2
1
- �
Job Reference (optional)
Al Moof Trusses, Fort Pierce, FL 34946, design(a7a1 truss.com rs.Izu s NOV Iz zv1 r Po i eK industries, inc. Thu may a um wivo zu i o rage i
I D:nKMLCG99vHyLG9D5?YIAEyzKd3P-tNzzjhMoptF?zvQRLUV4b2lsAEozBhfkdlEreGzKGVg
-0 -8 7-0-2
0- -8 I 7-0-2
3x4 =
3x6
3.54 12
2-5-1 $-10;-11
2-5-1 5�1
6-8-10
3-9-15
7-0-2
LOADING (psf)
SPACING- 2-0-0
1
DEFL. in (loc) I/deft
L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.48
Vert(LL) -0.02 4-5 >999
360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.41
Vert(CT) 0.03 4-5 >999
240
BCLL 0.0
Rep Stress Incr NO
WB 0.06
Horz(CT) -0.05 3 n/a
n/a
BCDL 10.0
Code FBC2017fTP12014
Matrix -MP
Weight: 36 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
4) Refer to girder(s� for truss to truss connections.
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
Standard
BRACING-
joint(s) 4 except (jt � Ib) 3=105, 5=719.
Vert: 1-3=80, 5-6=51, 4-5=-10
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
6) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13,
14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27,
Horz: 1-3=-90
Concentrated Loads (lb)
purlins.
BOT CHORD
28, 29, 30, 31, 32, 33, 34, 35 has/have been modified.
Building designer must review loads to verify that they
Vert: 8=72(F=36, B=36) 9=-45(F)10=83(F)
Horz: 7=-218(F=-109, B=-109)
Rigid ceiling directly applied or 10-0-0 oc bracing.
1
are correct for the i tended use of this truss.
r
5) Dead + 0.6 MWFRS Wind (Pos. Internal) Right:
MiTek recommends that Stabilizers and re uired
9
7) Hanger(s) or other connection device(s) shall be
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
cross bracing be installed during truss erection, in
provided sufficient>o support concentrated load(s) 109
accordance with Stabilizer Installation guide.
lb left at 1-5-0, and 109 lb left at 1-5-0, and 192 lb
Vert: 1-3=55, 4-6=-10
Horz: 1-3=-65
down and 236 lb up at 4-2-15 on top chord, and 84 lb
REACTIONS. (lb/size)
( )
down and 129 lb up at 1-5-0, and 84 lb down and 129
Concentrated Loads (lb)
3 = 33/Mechanical
lb up at 1-5-0, and 99 lb down and 190 lb up at
Vert: 8=B=123) 9=-11(F) 10=85(F)
4 = -88/Mechanical
4-2-15 on bottom chord. The design/selection of such
-218(F123,
Horz: 7=-218 F=-109, B=-109
( )
6) Dead + 0.6 MWFRS Wind (Neg. Internal) Left:
5 = 80010-11-5 min. 0-1-8
( )
connection devices) is the responsibility of others.
Lumber Increase=1.60, Plate Increase=1.60
Max Hors
5 = 403(LC 4)
8) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
Uniform Loads (pig
Max Uplift
Vert: 1-3=22, 5-6=41, 4-5=-20
3 =-105(LC 26)
Horz: 1-3=-52
4 = 1
LOAD CASE(S)
Concentrated Loads (lb)
5 -719(LC 8) )
=19(L8
Standard
Vert: 8=85(F=42, B=42) 9=17(F) 10=98(F)
Max Grav
3 = 50(LC 35)
1) Dead + Roof Live (balanced): Lumber Increase=1.25
Plate Increase=1.25
Horz: 7=-218 F=-109, B=-109
7 .
) Dead + 06 MWFRS Wind (Neg. Internal) Right:
=
4 58(LC 22)
rm
UnifoLoads (PI
Lumber Increase=1.60, Plate Increase=1.60
5 = 800(LC 1)
Vert: 1-3=-90, 4-6=-20
Uniform Loads (pig
Vert: 1-3=-2, 4-6=-20
Concentrated Loads (lb)
FORCES. (lb)
Vert: 8=-168(F=-84, B=-84) 9=95(F) 10=99(F)
Horz: 1-3=-28
Concentrated Loads (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
Horz: 7=-218(F=j'109, B=-109)
Vert: 8=258(F=129, B=129) 9=51(F) 10=99(F)
when shown.
BOT CHORD
2) Dead + 0.75 Roof Live (balanced): Lumber
Increase=1.25, Plate Increase=1.25
Horz: 7=-218(F=-109, B=-109)
1-5=0/403
Uniform Loads (plf)
8) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st
WEBS
Vert: 1-3=-75, 4-8=-20
Parallel: Lumber Increase=1.60, Plate
2-5=-543/482
Concentrated Loads (lb)
Increase=1.60
NOTES-
Vert: 8=-137(F=-69, B=-69) 9=95(F) 10=99(F)
Horz- 7=-218(F —109, B=-109)
Uniform Loads (pig
Vert: 1-3=-9 4-6=-10
1 Wind: ASCE 7-10; Vult=180m h 3-second gust)
P ( 9 )
3) Dead +Uninhabitable Attic Without Storage: Lumber
Horz: 1-3=-90
Concentrated Loads Ib
( )
Vasd=139mph; TCDL=S.Opsf; BCDL=5.0psf; h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
Increase=1.25, Plate Increase=1.25
Uniform Loads (pig
Vert: 8=246(F=123, B=123) 9=-45(F) 10=85(F)
cantilever left exposed ; Lumber DOL=1.60 plate grip
Vert: 1-3=-30, 4-6=40
Horz: 7=-218(F=-109, B=-109)
DOL=1.60
Concentrated Loads (lb)
9) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd
2) This truss has been designed for a 10.0 psf bottom
Vert: 8=-45(F=-23, B=-23) 9=95(F) 10=99(F)
Parallel: Lumber Increase=1.60, Plate
chord live load nonconcurrent with any other live loads.
*
Horz: 7=-218(F=-109, B=-109)
Increase=1.60
Uniform Loads (plf)
3) This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
4) Dead + 0.6 MWFRS Wind (Pos. Internal) Left:
Lumber Increase = 1.60, Plate Increase=1.60
Vert: 1-3=47, 4-6=-10
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
Uniform Loads (plf)
Horz: 1-3=-57
898 gnbg�%fl p9d&2y other members.
Concentrated Loads (lb)
Job
Truss
Truss Type
Qty
Ply
72005
HJSA
Diagonal Hip Girder
2
1
A0117256
Job Reference (optional)
� JV FLA5506, -UJL V1 cc, F� o Ua U, unaiynLd i u uss.wrn
I
LOAD CASE(S)
Standard
Concentrated Loads (lb)
Vert: 8=246(F=123, 13=123) 9=1(F) 10=85(F)
Horz: 7=-218(F=-109, B=-109)
10) Dead + 0.6 MWFRS Wind (Pos. Internal) 3rd
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=80, 4-6=-10
Horz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=246(F=123, B=123) 9=-45(F) 10=85(F)
Horz: 7=-218(F=-109, B=-109)
11) Dead + 0.6 MWFRS Wind (Pos. Internal) 4th
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=47, 4-6=-10
Horz: 1-3=-57
Concentrated Loads (lb)
Vert: 8=246(F=123, B=123) 9=1(F) 10=85(F)
Horz: 7=-218(F=-109, B=-109)
12) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=22, 4-6=-20
Horz: 1-3=-52
Concentrated Loads (lb)
Vert: 8=258(F=129, B=129) 9=17(F) 10=99(F)
Horz: 7=-218(F=-109, B=-109)
13) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-10, 4-6=-20
Horz: 1-3=-20
Concentrated Loads (lb)
Vert: 8=258(F=129, B=129) 9=63(F) 10=99(F)
Horz: 7=-218(F=-109, B=-109)
14) Dead: Lumber Increase=0.90, Plate Increase=0.90
Pit. metal=0.90
Uniform Loads (pig
Vert: 1-3=-30, 4-6=40
Concentrated Loads (lb)
Vert: 8=-45(F=-23, B=-23) 9=95(F) 10=99(F)
Horz: 7=-218(F=-109, B=-109)
15) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Ing Left): Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pIg
Vert: 1-3=-36, 5-6=26, 4-5=-20
Horz: 1-3=-39
Concentrated Loads (lb)
Vert: 8=64(F=32, 13=32) 9=131(F) 10=149(F)
Horz: 7=-218(F=-109, B=-109)
16) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Ing Right): Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pig
Vert: 1-3=-54, 4-6=-20
Horz: 1-3=-21
Concentrated Loads (lb)
Vert: 8=193(F=97, B=97) 9=157(F) 10=151(F)
Horz: 7=-218(F=-109, B=-109)
17) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60,
Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=-36, 4-6=-20
Horz: 1-3=-39
Concentrated Loads (lb)
Vert: 8=193(F=97, B=97) 9=131(F) 10=151(F)
Horz: 7=-218(F=-109, B=-109)
18) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60,
Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=-60, 4-6=-20
Horz: 1-3=-15
Concentrated Loads (lb)
a.izu s Nov 12 2u1 i MI Fek Industries, Inc. Thu May 3 09:16:03 2018 Page 2
I D: n KMLCG99vHyLG9D5?YIAEy2Kd 3P-tNzzj h MoptF?zvQRL U V4b2lsAEozBhfkdlEreGzKG Vg
i
Standard
Vert: 8=193(F=97, B=97) 9=166(F) 10=151(F)
Horz: 7=-218(F=-109, B=-109)
19) Reversal: Dead + Roof Live (balanced): Lumber
Increase=1.25, Plate Increase=1.25
Uniform Loads (pig
Vert: 1-3=-90, 4-6=-20
Concentrated Loads (lb)
Vert: 8=-45(F=-23, B=23) 9=236(F) 10=190(F)
Horz: 7=-218(F=-109, B=-109)
20) Reversal: Dead + 0.75 Roof Live (balanced):
Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pig
Vert: 1-3=-75, 4-6=-20
Concentrated Loads (lb)
Vert: 8=-45(F=-23, B=-23) 9=200(F) 10=167(F)
Horz: 7=-218(F=-109, B=-109)
21) Reversal: Dead: Lumber Increase=0.90, Plate
Increase=0.90 Pit. metal=0.90
Uniform Loads (pig
Vert: 1-3=-30, 4-6=-20
Concentrated Loads (lb)
Vert: 8=-45(F=-23, B=-23) 9=95(F) 10=99(F)
Horz: 7=-218(F=-109, B=-109)
z2) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
Left: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=80, 5-6=51, 4-5=-10
Horz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=-1 11 (F=-56, B=-56) 9=-192(F) 10=-99(F)
Horz: 7=-218(F=-109, B=-109)
23) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
Right: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pin
Vert: 1-3=55, 4-6=-10
Horz: 1-3=-65
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-157(F) 10=-97(F)
Horz: 7=-218(F=-1.09, B=-109)
24) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
Left: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=22, 5-6=41, 4-5=-20
Horz: 1-3=-52
Concentrated Loads (lb)
Vert: 8=-83(F=-42, B=-42) 9=-130(F) 10=-85(F)
Horz: 7=-218(F=-109, B=-109)
25) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
Right: Lumber Increase=1.60, Plate Increase=1.60'
Uniform Loads (pig
Vert: 1-3=-2, 4-6=-20
Horz: 1-3=-28
Concentrated Loads (lb)
Vert: 8=-25(F=-12, B=-12) 9=-95(F) 10=-83(F)
Horz: 7=-218(F=-109, B=-109)
26) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
1st Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pin
Vert: 1-3=80, 4-6=-10
Horz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-192(F) 10=-97(F)
Horz: 7=-218(F=-109, B=-109)
27) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
2nd Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Vert: 1-3=47, 4-6=-10
Horz: 1-3=-57
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-145(F) 10=-97(F)
Horz: 7=-218(F=-109, B=-109)
28) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
3rd Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Standard
Uniform Loads (pig
Vert: 1-3=80, 4-6=-10
Horz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-192(F) 10=-97(F)
Horz: 7=-218(F=-109, B=-109)
29) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
4th Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pig
Vert: 1-3=47, 4-6=-10
Horz: 1-3=-57
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-145(F) 10=-97(F)
Horz: 7=-218(F=-109, B=-109)
30) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
1st Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pig
Vert: 1-3=22, 4-6=-20
Horz:-1-3=-52
Concentrated Loads (lb)
Vert: 8=-25(F=-12, B=-12) 9=-130(F) 10=-83(F)
Horz: 7=-218(F=-109, B=-109)
31) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
2nd Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pig
Vert: 1-3=-10, 4-6=-20
Horz: 1-3=-20
Concentrated Loads (lb)
Vert: 8=-25(F=-12, B=-12) 9=-83(F) 10=-83(F)
Horz: 7=-218(F=-109, B=-109)
32) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) Left): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-36, 5-6=26, 4-5=-20
Horz: 1-3=-39
Concentrated Loads (lb)
Vert: 8=-142(F=-71, B=-71) 9=-81(F) 10=-50(F)
Horz: 7=-218(F=-109, B=-109)
33) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) Right): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=-54, 4-6=-20
Horz: 1-3=-21
Concentrated Loads (lb)
Vert: 8=-99(F=-49, 13=49) 9=-56(F) 10=-48(F)
Horz: 7=-218(F=-109, B=-109)
34) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) 1st Parallel): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=-36, 4-6=-20
Horz: 1-3=-39
Concentrated Loads (lb)
Vert: 8=-99(F=-49, 13=49) 9=81(F) 10=-48(F)
Horz: 7=-218(F=-109, B=-109)
35) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) 2nd Parallel): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-3=-60, 4-6=-20
Horz: 1-3=-15
Concentrated Loads (lb)
Vert: 8=-99(F=-49, B=-49) 9=-46(F)10=48(F)
Horz: 7=-218(F=-109, B=-109)
Job
Truss
Truss Type
Qty
Ply
A0117257
72005
HJ5C
DIAGONAL HIP GIRDER
2
1
Job Reference o tional
Al Roof Trusses, Fort Pierce, FL 3494b, design(cvaltruss.com
2-11-0
2x4 II
5x6
2x4 11
o. I N S IV V V I L LV I IVII I GIB 111-Li l-, II IL. 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-LZWMxl NRaANsb3_dvBOJBFH?UeBGw5KtrPzPAizKGVf
6-11-1
3.54 12
6-1
2x4 ��
2-7-9 6-7-9 6i11,-1
3
2-7-9 4-0-0 0-8
Plate Offsets (X Y)- 12:0-3-0 0-3-8)
LOADING (psf)
SPACING- 2-6-0
CSI.
DEFL. in (loc) I/defl L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.64
Vert(LL) 0.18 4-5 >444 360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.41
Vert(CT) 0.22 4-5 >362 240
_
BCLL 0.0
Rep Stress Incr NO
WB 0.23
Horz(CT) -0.18 3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 55 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP 2400F 2.0E
WEBS 2x6 SP No.2 *Except*
W2: 2x4 SP No.3
OTHERS 2x6 SP No.2
BRACING -
TOP CHORD
2-0-0 oc purlins (6-0-0 max.), except end verticals
(Switched from sheeted: Spacing > 2-0-0).
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS. (lb/size)
6 = 1136/0-11-5 (min.0-1-8)
3 = 282/Mechanical
4 = 19/Mechanical
Max Horz
6 = 636(LC 5)
Max Uplift
6 =-1034(LC 4)
3 =-328(LC 8)
4 =-480(LC 4)
Max Grav
1136(LC 1)
282(LC 1)
80(LC 3)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-6=-1029/382, 2-8=405/0
BOT CHORD
6-10=-580/0, 5-10=-580/0
WEBS
2-5=0/758
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left exposed ; end vertical left exposed; porch
left exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
Continued on page 2
3) ' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girders) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except (jt=1�) 6=1034, 3=328, 4=480.
6) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13,
14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27,
28, 29, 30, 31, 32 has/have been modified. Building
designer must review loads to verify that they are
correct for the intended use of this truss.
7) Graphical purlin representation does not depict the
size or the orientation of the purlin along the top and/or
bottom chord.
8) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s)134
lb left at 1-3-15, 134 lb left at 1-3-15, and 75 lb down
and 98 lb up at 4-1 114, and 75 lb down and 98 lb up
at 4-1-14 on top chord, and 99 lb down and 175 lb up
at 1-3-15, 99 lb down and 175lb up at 1-3-15, and 24
lb down and 153 lb up at 4-1-14, and 24 lb down and
153 lb up at 4-1-141ion bottom chord. The
design/selection of such connection device(s) is the
responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the
face of the truss arej noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live, (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-113, 2-3=-112, 4-6=-25
Concentrated Loads (lb)
Vert: 10=-198(F=;99, B=-99) 11=13(F=6, B=6)
Horz: 8=-268(F=-134, B=-134)
2) Dead + 0.75 Roofj Live (balanced): Lumber
Increase=1.25, Plate Increase=1.25
Uniform Loads (pli7
Vert: 1-2=-94, 2-3=-94, 4-6=-25
Concentrated Loads (lb)
Vert: 1 0=-1 54(F=-77, B=-77) 11=10(F=5, B=5)
Horz: 8=-268(F=-134, B=-134)
Standard
3) Dead + Uninhabitable Attic Without Storage: Lumber
Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-38, 2-3=-37, 4-6=-50
Concentrated Loads (lb)
Vert: 9=-3(F=-1, B=-1) 10=-24(F=-12, B=-12)
Horz: 8=-268(F=-134, B=-134)
4) Dead + 0.6 MWFRS Wind (Pos. Internal) Left:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pin
Vert: 1-2=153, 2-3=99, 4-6=64
Horz: 2-6=49, 1-2=-165, 2-3=-112
Concentrated Loads (lb)
Vert: 9=19(F=10, B=10) 10=130(F=65, B=65)
11 =89(F=44, B=44)
Horz: 8=-268(F=-134, B=-134)
5) Dead + 0.6 MWFRS Wind (Pos. Internal) Right:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=46, 2-3=69, 4-6=64
Horz: 2-6=-71, 1-2=-58, 2-3=-82
Concentrated Loads (lb)
Vert: 9=34(F=17, B=17) 10=130(F=65, B=65)
11 =89(F=44, B=44)
Horz: 8=-268(F=-134, B=-134)
6) Dead + 0.6 MWFRS Wind (Neg. Internal) Left:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pin
Vert: 1-2=51, 2-3=28, 4-6=52
Horz: 2-6=95, 1-2=-89, 2-3=-66
Concentrated Loads (lb)
Vert: 9=150(F=75, B=75) 10=130(F=65, B=65)
11=89(F=44,B=44)
Horz: 8=-268(F=-134, B=-134)
7) Dead + 0.6 MWFRS Wind (Neg. Intemal) Right:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-2=21, 2-3=-2, 4-6=52
Horz: 2-6=-24, 1-2=-58, 2-3=-35
Concentrated Loads (lb)
Vert: 9=165(F=82, B=82) 10=130(F=65, B=65)
11=89(F=44,B=44)
Horz: 8=-268(F=-134, B=-134)
Job
Truss
Truss Type
qty
Ply
72005
HJSC
DIAGONAL
HIP GIRDER
2
1
A0117257
Job Reference o tional
LOAD CASE(S)
Standard
8) Dead +0.6 MWFRS Wind (Pos. Internal) 1st Parallel:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-2=76, 2-3=99, 4-6=-13
Horz: 2-6=28, 1-2=-89, 2-3=-112
Concentrated Loads (lb)
Vert: 9=19(F=10, B=10) 10=350(F=175, 13=175)
11=305(F=153, B=153)
Horz: 8=-268(F=-134, B=-134)
9) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-2=35, 2-3=58, 4-6=-13
Horz: 2-6=-60, 1-2=-48, 2-3=-71
Concentrated Loads (lb)
Vert: 9=64(F=32, B=32) 10=350(F=175, B=175)
11=305(F=153, 13=153)
Horz: 8=-268(F=-134, B=-134)
10) Dead + 0.6 MWFRS Wind (Pos. Internal) 3rd
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-2=76, 2-3=99, 4-6=-13
Horz: 2-6=28, 1-2=-89, 2-3=-112
Concentrated Loads (lb)
Vert: 9=19(F=10, B=10) 10=350(F=175, B=175)
11=305(F=153, B=153)
Horz: 8=-268(F=-134, B=-134)
11) Dead + 0.6 MWFRS Wind (Pos. Internal) 4th
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=35, 2-3=58, 4-6=-13
Horz: 2-6=-60, 1-2=-48, 2-3=-71
Concentrated Loads (lb)
Vert: 9=64(F=32, B=32) 10=350(F=175, B=175)
11=305(F=153, B=153)
Horz: 8=-268(F=-134, B=-134)
12) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=51, 2-3=28, 4-6=-25
Horz: 2-6=75, 1-2=-89, 2-3=-66
Concentrated Loads (lb)
Vert: 9=150(F=75, B=75) 10=350(F=175, B=175)
11=305(F=153, B=153)
Horz: 8=-268(F=-134, B=-134)
13) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-2=10, 2-3=-13, 4-6=-25
Horz: 2-6=-14, 1-2=-48, 2-3=-24
Concentrated Loads (lb)
Vert: 9=195(F=98, B=98) 10=350(F=175, B=175)
11=305(F=153, B=153)
Horz: 8=-268(F=-134, B=-134)
14) Dead: Lumber Increase=0.90, Plate Increase=0.90
Pit. metal=0.90
Uniform Loads (plf)
Vert: 1-2=-38, 2-3=-37, 4-6=-25
Concentrated Loads (Ib)
Vert: 10=-24(F=-12, B=-12)
Horz: 8=-268(F=-134, B=-134)
15) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int) Left): Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pig
Vert: 1-2=-27, 2-3=-45, 4-6=32
Horz: 2-6=71, 1-2=-67, 2-3=-49
Concentrated Loads (lb) '
Vert: 9=113(F=56, B=56) 10=98(F=49, B=49)
11=76(F=38, B=38)
Horz: 8=-268(F=-134, B=-134)
16) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int) Right): Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pig
Continued on page 3
m20 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:16:04 2018 Page 2
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-LZW Mx1 NRaANsb3_dvBOJBFH?Ue8Gw5KtrPzPAizKGVf
Standard
Vert: 1-2=-50, 2-3=-67, 4-6=32
Horz: 2-6=-18, 1-2=-44, 2-3=-26
Concentrated Loads (lb)
Vert: 9=123(F=62, B=62) 10=98(F=49, 13=49)
11=76(F=38, 8=38)
Horz: 8=-268(F=-134, B=-134)
17) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int)1st Parallel): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-2=-27, 2-3=-45, 4-6=-25
Horz: 2-6=56, 1-2=-67, 2-3=-49
Concentrated Loads (lb)
Vert: 9=113(F=56, B=56) 10=262(F=131, B=131)
11=239(F=119, 13=119)
Horz: 8=-268(F=-134, B=-134)
.18) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int) 2nd Parallel): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-2=-58, 2-3=-75, 4-6=-25
Horz: 2-6=-11, 1-2=-36, 2-3=-18
Concentrated Loads (lb)
Vert: 9=146(F=73, B=73) 10=262(F=131, B=131)
11=239(F=119, 13=119)
Horz: 8=-268(F=-134, B=-134)
19) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
Left: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-2=153, 2-3=99, 4-6=64
Horz: 2-6=49, 1-2=-165, 2-3= 112
Concentrated Loads (Ib)
Vert: 9=-151(F=-75, B=-75) 10=-99(F=-50, B=-50)
11=-48(F=-24, B=-24) .
Horz: 8=-268(F=-134, B=-134)
20) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
Right: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-2=46, 2-3=69, 4-6=64
Horz: 2-6=-71, 1-2=-58, 2-3=-82
Concentrated Loads (lb)
Vert: 9=-151(F=-75, B=-75) 10=-99(F=-50, B=-50)
11=-48(F=-24, B=-24)
Horz: 8=-268(F=-134, B=-134)
21) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
Left: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=51, 2-3=28, 4-6=52
Horz: 2-6=95, 1-2=-89, 2-3=-66
Concentrated Loads (lb)
Vert: 9=-19(F=-10, B=-10) 10=-59(F=-30, B=-30)
11 =-42(F=-2 1, B=-21)
Horz: 8=-268(F=-134, B=-134)
22) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
Right: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-2=21, 2-3=-2, 4-6=52
Horz: 2-6=-24, 1-2=-58, 2-3=-35
Concentrated Loads (lb)
Vert: 9=-19(F=-10, B=-10) 10=-59(F=-30, B=-30)
11=-42(F=-21, B=-21)
Horz: 8=-268(F=-134, B=-134)
23) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
1st Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pig
Vert: 1-2=76, 2-3=99, 4-6=-13
Horz: 2-6=28, 1-2=-89, 2-3=112
Concentrated Loads (lb)
Vert: 9=-151(F=-75, B=-75) 10=-56(F=-28, B=-28)
11=-8(F=-4, B=-4)
Horz: 8=-268(F=-134, B=-134)
24) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
2nd Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pig
Standard
Vert: 1-2=35, 2-3=58, 4-6=-13
Horz: 2-6=-60, 1-2=-48, 2-3=-71
Concentrated Loads (lb)
Vert: 9=-151(F=-75, B=-75) 10=-56(F=-28, B=-28)
11=-8(F=-4, B=-4)
Horz: 8=-268(F=-134, B=134)
25) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
3rd Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Vert: 1-2=76, 2-3=99, 4-6=-13
Horz: 2-6=28, 1-2=-89, 2-3=-112
Concentrated Loads (lb)
Vert: 9=-151(F=-75, B=-75) 10=-56(F=-28, B=-28)
11=-8(F=-4, B=-4)
Horz: 8=-268(F=-134, B=-134)
26) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
4th Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Vert: 1-2=35, 2-3=58, 4-6=-13
Horz: 2-6=-60, 1-2=-48, 2-3=-71
Concentrated Loads (lb)
Vert: 9=-151(F=-75, B=-75) 10=-56(F=-28, B=-28)
11=-8(F=-4, B=-4)
Horz: 8=-268(F=-134, B=-134)
27) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
1st Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Vert: 1-2=51, 2-3=28, 4-6=-25
Horz: 2-6=75, 1-2=-89, 2-3=-66
Concentrated Loads (lb)
Vert: 9=-19(F=-10, B=-10) 10=-17(F=-8, B=-8)
11=-2(F=-1, B=-1)
Horz: 8=-268(F=-134, B=-134)
28) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
2nd Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (pig
Vert: 1-2=10, 2-3=-13, 4-6=-25
Harz: 2-6=-14, 1-2=-48, 2-3=-24
Concentrated Loads (lb)
Vert: 9=-19(F=-10, B=-10) 10=-17(F=-8, B=-8)
11=-2(F=-1, B=-1)
Horz: 8=-268(F=-134, B=-134)
29) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) Left): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-2=-27, 2-3=-45, 4-6=32
Horz: 2-6=71, 1-2=-67, 2-3=-49
Concentrated Loads (lb)
Vert: 9=-15(F=-7, B=-7) 10=-148(F=-74, B=-74)
11=-22(F=-11, B=-11)
Horz: 8=-268(F=-134, B=-134)
30) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) Right): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-2=-50, 2-3=-67, 4-6=32
Horz: 2-6=-18, 1-2=-44, 2-3=-26
Concentrated Loads (lb)
Vert: 9=-15(F=-7, B=-7)10=-148(F=-74, B=-74)
11=-22(F=-11, B=-11)
Horz: 8=-268(F=-134, B=-134)
31) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) 1st Parallel): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-2=-27, 2-3=-45, 4-6=-25
Horz: 2-6=56, 1-2=-67, 2-3=-49
Concentrated Loads (lb)
Vert: 9=-15(F=-7, B=-7) 10=-116(F=-58, B=-58)
11=8(F=4, B=4)
Horz: 8=-268(F=-134, B=-134)
Job
Truss
Truss Type
Qty
Ply
A0117257
72005
HJSC
DIAGONAL HIP GIRDER
2
1
Job Reference (optional)
Al Root Trusses, Fort Pierce, FL 34946, cesign(mal truss.com 0. 1 w 5 NUV 14 ZU if IVII I UK II WUDU ICJ, II W. I! IU IVICY J U. IU- GU ro rO9. J
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-LZW Mx1 NRaANsb3_dvBOJBFH?Ue8Gw5KtrPzPAizKGVf
LOAD CASE(S)
Standard
32) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. lint) 2nd Parallel): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-58, 2-3=-75, 4-6=-25
Horz: 2-6=-11, 1-2=-36, 2-3=-18
Concentrated Loads (lb)
Vert: 9=-15(F=-7, B=-7) 10=-116(F=-58, B=-58)
11=8(F=4, B=4)
Horz: 8=-268(F=-134, B=-134)
Job
Truss
Truss Type
Qty
Ply
72005
HR
Diagonal
Hip Girder
1
1
A0117259
Al D...dTmcc.�n C..A D:.......
E.-A..,.._:__�_,._.__
___
Job Reference optional
-�•a••� • •• o. izu s rvuv iz zu_i r mi i eK mausrnes, inc. I nu May 3 09:16:05 2018 Page 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-pm4k8NO3LU VjCDZgTvXYgTgAk1 RTfZvl43)yi9zKG Ve
Us 11
2-5-1
10-11
9-6-9
9 10 1
2-5-1
5-1
6-7-14
_3-
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defl
L/d
PLATES GRIP
TCLL
30.0
Plate Grip DOL
1.25
TC 0.61
Vert(LL)
-0.09 4-5
>892
360
MT20 244/190
TCDL
15.0
Lumber DOL
1.25
BC 0.60
Vert(CT)
0.10 4-5
>827
240
BCLL
0.0
Rep Stress Incr
NO
WB 0.08
Horz(CT)
-0.08 3
n/a
n/a
BCDL
10.0
Code FBC2017[TP12014
Matrix -MS
Weight: 49 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
185/Mechanical
4 =
-9/Mechanical
5 =
685/0-11-5 (min. 0-1-8)
Max Harz
5 =
477(LC 4)
Max Uplift
3 =
-236(LC 4)
4 =
-55(LC 19)
5 =
-787(LC 8)
Max Grav
3 =
185(LC 1)
4 =
112(LC 24)
5 =
871(LC 35)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-288/113
BOT CHORD
1-5=0/477
WEBS
2-5=-646/609
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left exposed ; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
Continued on page 2
3) * This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) 4 except (jt=lb) 3=236, 5=787.
16) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13,
14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27,
128, 29, 30, 31, 32, 33, 34, 35 has/have been modified.
Building designer must review loads to verify that they
are correct for the intended use of this truss.
7) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s)109
lb left at 1-5-0, 109 lb left at 1-5-0, 192 lb down and
236 lb up at 4-2-15, 192 lb down and 236 lb up at
4-2-15, and 59 lb down and 96 lb up at 7-0-14, and 59
lb down and 96 lb up at 7-0-14 on top chord, and 84
lb down and 129 lb up at 1-5-0, 84 lb down and 129 lb
up at 1-5-0, 99 lb down and 190 lb up at 4-2-15, 99 lb
down and 190 lb up at 4-2-15, and 26 lb down and 18
lb up at 7-0-14, and 26 lb down and 18 lb up at
7-0-14 on bottom chord. The design/selection of such
connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-90, 4-6=-20
Concentrated Loads (lb)
Vert: 8=-168(F=-84, B=-84) 9=190(F=95, B=95)
11=197(F=99,B=99)
Harz: 7=-218(F=-109, B=-109)
2) Dead + 0.75 Roof Live (balanced): Lumber
Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-75, 4-6=-20
Concentrated Loads (lb)
Vert: 8=-137(F=-69, B=-69) 9=190(F=95, B=95)
11 =1 97(F=99, B=99)
Harz: 7=-218(F=-109, B=-109)
Standard
3) Dead + Uninhabitable Attic Without Storage: Lumber
Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-30, 4-6=40
Concentrated Loads (lb)
Vert: 8=-45(F=-23, B=-23) 9=190(F=95, B=95)
10=11(F=5, B=5) 11=197(F=99, B=99)
Harz: 7=-218(F=-109, B=-109)
4) Dead + 0.6 MWFRS Wind (Pos. Internal) Left:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=80, 5-6=51, 4-5=-10
Harz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=72(F=36, B=36) 9=-90(F=-45, 13=45)
11=167(F=83, B=83) 12=2(F=1, B=1)
Harz: 7=-218(F=-109, B=-109)
5) Dead + 0.6 MWFRS Wind (Pos. Internal) Right:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=55, 4-6=-10
Harz: 1-3=-65
Concentrated Loads (lb)
Vert: 8=246(F=123, B=123) 9=-22(F=-11, 13=-11)
10=65(F=32,B=32)11=171(F=85,B=85)12=2(F=1,
B=1)
Harz: 7=-218(F=-109, B=-109)
6) Dead + 0.6 MWFRS Wind (Neg. Internal) Left:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=22, 5-6=41, 4-5=-20
Harz: 1-3=-52
Concentrated Loads (lb)
Vert: 8=85(F=42, B=42) 9=33(F=17, B=17)
10=104(F=52,B=52)11=195(F=98,B=98)
12=2(F=1,B=1)
Harz: 7=-218(F=-109, B=-109)
7) Dead + 0.6 MWFRS Wind (Neg. Internal) Right:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-2, 4-6=-20
Harz: 1-3=-28
Concentrated Loads (lb)
Job
Truss
Truss Type
Qty
Ply
A0117259
72005
HJ7
Diagonal Hip Girder
1
1
I
Job Reference (optional)
•0 2018 P
Al Roof Trusses, Fort Pierce, FL 34946, design(a�altruss.com
LOAD CASE(S)
Standard
Concentrated Loads (lb)
Vert: 8=258(F=129, B=129) 9=102(F=51, 13=51)
10=168(F=84,B=84)11=199(F=99,B=99)12=2(F=1,
B=1)
Horz: 7=-218(F=-109, B=-109)
8) Dead + 0.6 MWFRS Wind (Pos. Internal) 1 st Parallel:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=80, 4-6=-10
Horz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=246(F=123, B=123) 9=-90(F=-45, B=-45)
11=171(F=85, B=85)12=2(F=1, B=1)
Horz: 7=-218(F=-109, B=-109)
9) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=47, 4-6=-10
Horz: 1-3=-57
Concentrated Loads (lb)
Vert: 8=246(F=123, B=123) 9=3(F=1, B=1)
10=89(F=44,B=44)11=171(F=85,B=85)12=2(F=1,
B=1)
Horz: 7=-218(F=-109, B=-109)
10) Dead + 0.6 MWFRS Wind (Pos. Internal) 3rd
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=80, 4-6=-10
Horz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=246(F=123, B=123) 9=-90(F=-45, B=-45)
11=171(F=85,B=85)12=2(F=1,B=1)
Horz: 7=-218(F=-109, B=-109)
11) Dead + 0.6 MWFRS Wind (Pos. Internal) 4th
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=47, 4-6=-10
Horz: 1-3=-57
Concentrated Loads (lb)
Vert: 8=246(F=123, B=123) 9=3(F=1, B=1)
10=89(F=44,B=44)11=171(F=85,B=85)12=2(F=1,
B=1)
Horz: 7=-218(F=-109, B=-109)
12) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=22, 4-6=-20
Horz: 1-3=-52
Concentrated Loads (lb)
Vert: 8=258(F=129, B=129) 9=33(F=17, B=17)
10=104(F=52, B=52) 11=199(F=99, B=99) 12=2(F=1,
B=1)
Horz: 7=-218(F=-109, B=-109)
13) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-10, 4-6=-20
Horz: 1-3=-20
Concentrated Loads (lb)
Vert: 8=258(F=129, B=129) 9=126(F=63, B=63)
10=193(F=96,B=96)11=199(F=99,B=99)12=2(F=1,
B=1)
Horz: 7=-218(F=-109, B=-109)
14) Dead: Lumber Increase=0.90, Plate Increase=0.90
Pit. metal=0.90
Uniform Loads (plf)
Vert: 1-3=-30, 4-6=-20
Concentrated Loads (lb)
Vert: 8=-45(F=-23, B=-23) 9=190(F=95, B=95)
11=197(F=99,B=99)
Horz: 7=-218(F=-109, B=-109)
15) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int) Left): Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Continued on page 3
8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09.
Standard
Vert: 1-3=-36, 5-6=26, 4-5=-20
Horz: 1-3=-39
Concentrated Loads (lb)
Vert: 8=64(F=32, B=32) 9=262(F=131, B=131)
10=78(F=39, B=39)11=298(F=149, B=149)
12=22(F=11,B=11)
Horz: 7=-218(F=-109, B=-109)
16) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int) Right): Lumber Increase=1.60,
Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-54, 4-6=-20
Horz: 1-3=-21
Concentrated Loads (lb)
Vert: 8=193(1797, 13=97) 9=314(F=157, B=157)
10=126(F=63,113=63)11=301(F=151,E=151)
12=22(F=11,B=11)
Horz: 7=-218(F=-109, B=-109)
17) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int) 1st Parallel): Lumber
Increase=1.60! Plate Increase=1.60
Uniform Loadsl(plf)
Vert: 1-3=-36, 4-6=-20
Horz: 1-3=-39
Concentrated Loads (lb)
Vert: 8=193(F i97, B=97) 9=262(F=131, 13=131)
10=78(F=39, 6=39)11=301(F=151, B=151)
12=22(F=11,B==11)
Horz: 7=-218(F=-109, B=-109)
18) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int) 2nd Parallel): Lumber
lnc;rease=1.60,1 Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-60, 4-6=-20
Horz: 1-3=-15
Concentrated Loads (lb)
Vert: 8=193(17=�,97, B=97) 9=332(F=166, B=166)
10=145(F=72,P=72)11=301(F=151,E=151)
12=22(F=11, B1 11)
Horz: 7=-218(F -109, B=-109)
19) Reversal: Dead + Roof Live (balanced): Lumber
Increase=1.25, I Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-90, 4-6=-20
Concentrated Loads (lb)
Vert: 8=-45(F= j23, B=-23) 9=471(F=236, B=236)
11=380(F=190,1B=190)12=36(F=18,B=18)
Horz: 7=-218(F- -109, B=-109)
20) Reversal: Dead + 0.75 Roof Live (balanced):
Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-75, 4-6=-20
Concentrated Loads (lb)
Vert: 8=-45(F=-23, 8=-23) 9=401(F=200, 13=200)
11=334(F=167,1B=167)12=27(F=14,B=14)
Horz: 7=-218(F -109, B=-109)
21) Reversal: Dead: Lumber Increase=0.90, Plate
Increase=0.90 Pit. metal=0.90
Uniform Loads (plf)
Vert: 1-3=-30, 46=-20
Concentrated Loads (lb)
Vert: 8=-45(F=-23, B=-23) 9=190(F=95, B=95)
11=197(F=99,B=99)
Horz: 7=-218(F -109, B=-109)
22) Reversal: Dead+ 0.6 MWFRS Wind (Pos. Internal)
Left: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=80, 5-6=51, 4-5=-10
Horz:1-3=-90 1
Concentrated Loads (lb)
Vert: 8=-1 11 (F=-56, B=-56) 9=-383(F=-192,
B=-192) 1 0=-1 1 8(F=-59, B=-59) 11 =-1 98(F=-99,
B=-99) 12=-52(F=-26, B=-26)
Horz: 7=-218(F=-109, B=-109)
23) Reversal: Dead 1+ 0.6 MWFRS Wind (Pos. Internal)
Right: Lumber I crease=1.60, Plate Increase=1.60
Standard
Uniform Loads (plf)
Vert: 1-3=55, 4-6=-10
Horz: 1-3=-65
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-315(F=-157, B=-157)
1 0=-1 18(F=-59, B=-59) 11 =-1 94(F=-97, B=-97)
12=-52(F=-26, B=-26)
Horz: 7=-218(F=109, B=-109)
24) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
Left: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=22, 5-6=41, 4-5=-20
Horz: 1-3=-52
Concentrated Loads (lb)
Vert: 8=-83(F=-42, B=-42) 9=-260(F=-130, B=-130)
11 =1 70(F=-85, B=-85) 12=-52(F=-26, B=-26)
Horz: 7=-218(F=-109, B=-109)
25) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
Right: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-2, 4-6=-20
Horz: 1-3=-28
Concentrated Loads (lb)
Vert: 8=-25(F=-12, B=-12) 9=-1 9 1 (F=-95, B=-95)
11 =-1 66(F=-83, B=-83) 12=-52(F=-26, B=-26)
Horz: 7=-218(F=-109, B=-109)
26) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
1st Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Vert: 1-3=80, 4-6=-10
Horz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-383(F=-192, B=-192)
1 0=-1 18(F=-59, B=-59) 11=-194(F=-97, B=-97)
12=-52(F=-26, B=-26)
Horz: 7=-218(F=-109, B=-109)
27) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
2nd Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Vert: 1-3=47, 4-6=-10
Horz: 1-3=-57
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-290(F=-145, B=-145)
1 0=-1 18(F=-59, B=-59) 11 =-1 94(F=-97, B=-97)
12=-52(F=-26, B=-26)
Horz: 7=-218(F=-109, B=-109)
28) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
3rd Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Vert: 1-3=80, 4-6=-10
Horz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-383(F=-192, B=-192)
1 0=-1 18(F=-59, B=-59) 11 =-1 94(F=-97, B=-97)
12=-52(F=-26, B=-26)
Horz: 7=-218(F=-109, B=-109)
29) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
4th Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Vert: 1-3=47, 4-6=-10
Horz: 1-3=-57
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-290(F=-145, B=-145)
10=-118(F=-59, B=-59) 11 =-1 94(F=-97, B=-97)
12=-52(F=-26, B=-26)
Horz: 7=-218(F=-109, B=-109)
30) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
1st Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Vert: 1-3=22, 4-6=-20
Horz: 1-3=-52
Job
Truss
Truss Type
Qty
Ply
72005
HR
Diagonal
Hip Girder
1
1
A0117259
Job Reference o tional
n t\UUUb-, rUl l rlGl U, rL J9 U, UUbIgIIIW_d ILIUSS.WIIr I ti.1 ZU s Nov 1Z ZU11 Mi I ek Industries, Inc. Thu May 3 09:16:05 2018 Page 3
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-pm4k8NO3LUVjCDZgTvXYgTgAli1 RTfZv143jyi9zKGVe
LOAD CASE(S)
Standard
Concentrated Loads (lb)
Vert: 8=-25(F=-12, B=-12) 9=-260(F=-130, B=-130)
11=-166(F=-83, B=-83) 12=-52(F=-26, B=-26)
Horz: 7=-218(F=-109, B=-109)
31) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
2nd Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-10, 4-6=-20
Horz: 1-3=-20
Concentrated Loads (lb)
Vert: 8=-25(F=-12, B=-12) 9=-167(F=-83, B=-83)
11=-166(F=-83, B=83) 12=-52(F=-26, B=-26)
Horz: 7=-218(F=-109, B=-109)
32) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60
, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-36, 5-6=26, 4-5=-20
Horz: 1-3=-39
Concentrated Loads (lb)
Vert: 8=-142(F=-71, B=-71) 9=-163(F=-81, B=-81)
11=-99(F=-50, B=-50) 12=-19(F=-9, B=-9)
Horz: 7=-218(F=-109, B=-109)
33) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) Right): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-54, 4-6=-20
Horz: 1-3=-21
Concentrated Loads (lb)
Vert: 8=-99(F=-49, B=-49) 9=-1 11 (F=-56, B=-56)
11=-96(F=-48, B=-48) 12=-19(F=-9, B=-9)
Horz: 7=-218(F=-109, B=-109)
34) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) 1st Parallel): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-36, 4-6=-20
Horz: 1-3=-39
Concentrated Loads (lb)
Vert: 8=-99(F=-49, B=-49) 9=-163(F=-81, B=-81)
11=-96(F=-48, B=-48) 12=-1 9(F=-9, B=-9)
Horz: 7=-218(F=-109, B=-109)
35) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) 2nd Parallel): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-60, 4-6=-20
Horz: 1-3=-15
Concentrated Loads (lb)
Vert: 8=-99(F=-49, B=-49) 9=-93(F=-46, 13=46)
11=-96(F=-48, B=-48) 12=-19(F=-9, B=-9)
Horz: 7=-218(F=-109, B=-109)
Job
Truss
Truss Type
Qty
Ply
A0117258
72005
HJ7-3
Diagonal Hip Girder I
2
1
}
Job Reference (optional)
Al Root I cusses, Fort Nlerce, FL J4&4b, aesignLal miss.com
0., vo, ,c ' rvu'cn u,uuauica, u,�. n
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-Hye6LjPh6odagN80Oc2nDgNldRipO1 LAJjSVEbzKGVd
9-10-1 ,
2
2.12 12
9
8
T1
f9
T
N
1
Of
B1
I
6x6 = 10
p• 11
12
3
3x4 =
p 0.
4
2-6-7
3-0-2 ,
9=6-9
8-10-,1
2-6-7
0-5-10
1 6-6-7
-3-
Plate Offsets (X Y)— (1:0-6-11 Edge)
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.72
Vert(LL) -0.19 3-4 >437 360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.85
Vert(CT) , 0.16 3-4 >501 240
BCLL 0.0
Rep Stress Incr NO
WB 0.00
Horz(CT) 0.06 2 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 47 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
6) Hanger(s) or otFter connection device(s) shall be
BOT CHORD 2x6 SP No.2
provided sufficient support concentrated load(s) 154
BRACING-
Ito
lb down and 162 Ib up at 4-2-15, 154 lb down and 162
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
lb up at 4-2-15, anld 62 lb down and 84 lb up at
7-0-14, and 62 lb down and 84 lb up at 7-0-14 on top
pudins.
chord, and 86 lb down and 157 lb up at 1-5-0, 86 lb
BOTCHRigid
down and 157 lb up at 1-5-0, 388 lb down and 326 lb
ceiliORD ng directly applied or 8-3 6 oc bracing.
up at 4-2-15, 3881. down and 326 lb up at 4-2-15,
MiTek recommends that Stabilizers and required
and 129 lb down and 102 lb up at 7-0-14, and 129 lb .
cross bracing be installed during truss erection, in
down and 102 lb up at 7-0-14 on bottom chord. The
accordance with Stabilizer Installation guide.
design/selection oflsuch connection device(s) is the
responsibility of others.
REACTIONS. (lb/size)
7) In the LOAD CASE(S) section, loads applied to the
2 = 208/Mechanical
face of the truss ar6 noted as front (F) or back (B).
3 = -71/Mechanical
4 = 605/0-11-5 (min. 0-1-8)
Max Horz
LOAD CASE(S)
4 = 155(LC 4)
Standard
Max Uplift
1) Dead + Roof Live (balanced): Lumber Increase=1.25
2 =-217(LC 4)
Plate Increase 1.25
3 =-193(LC 16)
Uniform Loads (plf)
4 =-1034(LC 4)
Vert: 1-2=-90, 3-�=-20
Max Grav
Concentrated Loads (lb)
2 = 208(LC 1)
Vert: 8=127(F=6, B=64) 10=-173(F=-86, B=-86)
,
11=317(F=158,B=158)12=64(F=32,B=32)
4 = 970(LC 35)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left exposed ; porch left exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 100 lb uplift at
joint(s) except (jt=lb) 2=217, 3=193, 4=1034.
Job
Truss
Truss Type
Qty
Ply
72005
HRA
Diagonal Hip Girder
2
1
A0117260
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com
3x8 11
8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:16:07 2018 Page 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-18CUZ2QJt51QSXjCaKa0muvRjr307TTJYNCtln 1 zKGVc
9-10-1
LOADING(psf)
SPACING-
2-0-0
1 CSI.
DEFL.
in
(loc)
I/deft
L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.89
Vert(LL)
-0.11
4-5
>730
360
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.79
Vert(CT)
0.13
4-5
>628
240
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.07
Horz(CT)
-0.10
3
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 49 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 9-8-4 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation uide.
REACTIONS. (lb/size)
3 =
163/Mechanical
4 =
-28/Mechanical
5 =
588/1-5-12 (min. 0-1-8)
Max Horz
5 =
477(LC 4)
Max Uplift
3 =
-243(LC 4)
4 =
-156(LC 5)
5 =
-946(LC 4)
Max Grav
3 =
164(LC 35)
4 =
99(LC 31)
5 =
1050(LC 35)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-269/112
BOT CHORD
1-5=0/477
WEBS
2-5=-627/567
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left exposed ; porch left exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
Continued on page 2
3) * This truss has been designed for a live load of
, 20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except at --lb) 3=243, 4=156, 5=946.
6) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13,
14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27,
28, 29, 30, 31, 32, 33, 34, 35 has/have been modified.
Building designer must review loads to verify that they
are correct for the intended use of this truss.
7) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 109
lb left at 1-5-0, 109 lb left at 1-5-0, 249 lb down and
306 lb up at 4-2-15, 249 lb down and 306 lb up at
4-2-15, and 49 lb down and 83 lb up at 7-0-14, and 49
lb down and 83 lb up at 7-0-14 on top chord, and 84
lb down and 129 lb up at 1-5-0, 84 lb down and 129 lb
up at 1-5-0, 277 lb down and 274 lb up at 4-2-15, 277
lb down and 274 lb up at 4-2-15, and 91 lb down and
73 lb up at 7-0-14, and 91 lb down and 73 lb up at
7-0-14 on bottom chord. The design/selection of such
connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-90, 4-6=-20
Concentrated Loads (lb)
Vert: 8=-168(F=-84, B=-84) 9=250(F=125, B=125)
11=276(F=138,B=138)
Horz: 7=-218(F=-109, B=-109)
2) Dead + 0.75 Roof Live (balanced): Lumber
Increase=1.25, Plate Increase=1.25
Uniform Loads (pig
Vert: 1-3=-75, 4-6=-20
Concentrated Loads (lb)
Vert: 8=-137(F=-69, B=-69) 9=250(F=125, B=125)
11=276(F=138,E=138)
Horz: 7=-218(F=-109, B=-109)
Standard
3) Dead + Uninhabitable Attic Without Storage: Lumber
Increase=1.25, Plate Increase=1.25
Uniform Loads (pIg
Vert: 1-3=-30, 4-6=-40
Concentrated Loads (lb)
Vert: 8=45(F=-23, B=-23) 9=250(F=125, B=125)
10=15(F=7,B=7)11=276(F=138,B=138)
Horz: 7=-218(F=-109, B=-109)
4) Dead + 0.6 MWFRS Wind (Pos. Internal) Left:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plg
Vert: 1-3=80, 4-6=51
Horz: 1-3=-90
Concentrated Loads (lb)
Vert:8=72(F=36, B=36)9=-61(F=-31, B=-31)
11=44(F=22, B=22) 12=2(F=1, 6=1)
Horz: 7=-218(F=-109, B=-109)
5) Dead + 0.6 MWFRS Wind (Pos. Internal) Right:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plg
Vert: 1-3=55, 5-6=-10, 4-5=51
Horz: 1-3=-65
Concentrated Loads (lb)
Vert: 8=246(F=123, B=123) 9=8(F=4, B=4)
10=44(F=22, B=22) 11=58(F=29, B=29) 12=2(F=1,
B=1)
Horz: 7=-218(F=-109, B=-109)
6) Dead + 0.6 MWFRS Wind (Neg. Internal) Left:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=22, 4-6=41
Horz: 1=3=-52
Concentrated Loads (lb)
Vert: 8=85(F=42, B=42) 9=83(F=41, B=41)
10=98(F=49, B=49) 11=72(F=36, B=36) 12=2(F=1,
B=1)
Horz: 7=-218(F=-109, B=-109)
7) Dead + 0.6 MWFRS Wind (Neg. Internal) Right:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pIg
Vert: 1-3=-2, 5-6=-20, 4-5=41
Horz: 1-3=-28
Concentrated Loads (lb)
Job
Truss
Truss Type
Qty
Ply
A0117260
72005
HRA
Diagonal Hip Girder
2
1
0-1
Job Reference (optional)
Al Roof Trusses, Fort Fierce, FL :14946, cesign(aal rNSS.COm
LOAD CASE(S)
Standard
Concentrated Loads (lb)
Vert: 8=258(F=129, 13=129) 9=152(F=76, B=76)
10=142(F=71, B=71) 11=87(F=43, 13=43) 12=2(F=1,
B=1)
Horz: 7=-218(F=-109, B=-109)
8) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=80, 4-6=-10
Horz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=246(F=123, B=123) 9=-61(F=-31, B=-31)
11=217(F=109, B=109) 12=146(F=73, 13=73)
Horz: 7=-218(F=-109, B=-109)
9) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel:
Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=47, 4-6=-10
Horz: 1-3=-57
Concentrated Loads (lb)
Vert: 8=246(F=123, B=123) 9=32(F=16, B=16)
10=68(F=34,13=34)11=217(17=109,E=109)
12=146(F=73,B=73)
Horz: 7=-218(F=-109, B=-109)
10) Dead + 0.6 MWFRS Wind (Pas. Internal) 3rd
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=80, 4-6=-10
Horz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=246(F=123, B=123) 9=-61(F=-31, B=-31)
11=217(F=109, B=109) 12=146(F=73, B=73)
Horz: 7=-218(F=-109, B=-109)
11) Dead + 0.6 MWFRS Wind (Pos. Internal) 4th
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=47, 4-6=-10
Horz: 1-3=-57
Concentrated Loads (lb)
Vert: 8=246(F=123, B=123) 9=32(F=16, B=16)
10=68(F=34, B=34) 11=217(F=109, B=109)
12=146(F=73, 13=73)
Horz: 7=-218(F=-109, B=-109)
12) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plo
Vert: 1-3=22, 4-6=-20
Horz: 1-3=-52
Concentrated Loads (lb)
Vert: 8=258(F=129, B=129) 9=83(F=41, 13=41)
10=98(F=49, B=49) 11=246(F=123, B=123)
12=146(F=73,B=73)
Horz: 7=-218(F=l09, B=-109)
13) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd
Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-10, 4-6=-20
Horz: 1-3=-20
Concentrated Loads (lb)
Vert: 8=258(F=129, B=129) 9=176(F=88, B=88)
10=167(F=83, B=83) 11=246(F=123, B=123)
12=146(F=73,B=73)
Horz: 7=-218(F=-109, B=-109)
14) Dead: Lumber Increase=0.90, Plate Increase=0.90
Plt. metal=0.90
Uniform Loads (plf)
Vert: 1-3=-30, 4-6=-20
Concentrated Loads (lb)
Vert: 8=-45(F=-23, 8=-23) 9=250(F=125, B=125)
11=276(F=138, B=138)
Horz: 7=-218(F=-109, B=-109)
15) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int) Left): Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Continued on page 3
o. icub im- is cuji cn 11
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-18CUZ2QJt51QSXjCaKaOmuvRjr307TTJYNC3n 1 zKGVc
Standard
Vert: 1-3=-36, 4-6=26
Horz: 1-3=-39
Concentrated Loads (lb)
Vert: 8=64(F=32, 13=32) 9=359(F=180, B=180)
10=74(F=37, 6=37) 11=276(F=138, B=138)
12=29(F=15, B=15)
Horz: 7=-218(F=-109, B=-109)
16) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int) Right): Lumber Increase=1.60,
Plate Increase=1.60
Uniform Loads (plf)
Vert. 1-3=-54,15-6=-20, 4-5=26
Horz: 1-3=-21
Concentrated Loads (lb)
Vert. 8=193(17=97, B=97) 9=41l(F=206, E=206)
10=107(F=53,IB=53) 11=287(F=143, B=143)
12=29(F=15, 13=15)
Horz: 7=-218(F=-109, B=-109)
17) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int) 1st Parallel): Lumber
Increase=1.60I Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-36, 4-6=-20
Horz: 1-3=-39
Concentrated Loads (lb)
Vert: 8=193(F 97, B=97) 9=359(F=180, B=180)
10=74(F=37, B=37) 11=406(F=203, B=203)
12=137(F=69, B=69)
Horz: 7=-218(�=-109, B=-109)
18) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS
Wind (Neg. Int) 2nd Parallel): Lumber
Increase=1.60j Plate Increase=1.60
Uniform Loadsl(plf)
Vert: 1-3=-60, 4-6=-20
Horz: 1-3=-15
Concentrated Loads (lb)
Vert: 8=193(F=,97, B=97) 9=429(F=215, B=215)
10=125(F=62, B=62) 11=406(F=203, B=203)
12=137(F=69, B=69)
Harz: 7=-218(F,=-109, B=-109)
19) Reversal: DQ + Roof Live (balanced): Lumber
Increase=1.25,Plate Increase=1.25
Uniform Loads ,(plf)
Vert: 1-3=-90, 4-6=-20
Concentrated Loads (lb)
Vert: 8=-45(F= j23, B=-23) 9=611(F=306, B=306)
11=548(F=274,1B=274)12=50(F=25,B=25)
Horz: 7=-218(F- -109, B=-109)
20) Reversal: Dead + 0.75 Roof Live (balanced):
Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads, plf)
Vert: 1-3=-75, 4-6=-20
Concentrated Loads (lb)
Vert: 8=45(1==-23, B=-23) 9=521(F=260, 13=260)
11=480(F=240,1E=240) 12=37(F=19, B=19)
Horz: 7=-218(F= -109, B=-109)
21) Reversal: Dead; Lumber Increase=0.90, Plate
Increase=0.90 Plt. metal=0.90
Uniform Loads (plf)
Vert: 1-3=-30, 4, 6=-20
Concentrated Loads (lb)
Vert: 8=-45(F=-23, B=-23) 9=250(F=125, B=125)
11=276(F=138, B=138)
Horz: 7=-218(FL109, B=-109)
22) Reversal: Deadl+ 0.6 MWFRS Wind (Pos. Internal)
Left: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=80, 4-6=51
Horz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=-111(F=i56, B=-56) 9=-498(F=-249,
B=-249) 10=-98(F=-49, B=-49) 11=-554(F=-277,
B=-277) 12=-182(F=-91, B=-91)
Horz: 7=-218(F --109,
23) Reversal: Dead 1 0.6 MWFRS Wind (Pos. Internal)
Right: Lumber Ir crease=1.60, Plate Increase=1.60
Standard
Uniform Loads (plf)
Vert: 1-3=55, 5-6=-10, 4-5=51
Horz: 1-3=-65
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-429(F=-215, B=-215)
10=-98(F=-49, B=-49) 11=-539(F=-270, B=-270)
12=-182(F=-91, B=-91)
Horz: 7=-218(F=-109, B=-109)
24) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
Left: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=22, 4-6=41
Horz: 1-3=-52
Concentrated Loads (lb)
Vert: 8=-83(F=42, B=-42) 9=-354(F=-177, B=-177)'
11=-525(F=-263, B=-263) 12=-182(F=-91, B=-91)
Horz: 7=-218(F=-109, B=-109)
25) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
Right: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-2, 5-6=-20, 4-5=41
Horz: 1-3=-28
Concentrated Loads (lb)
Vert: 8=-25(F=-12, B=-12) 9=-285(F=-142, B=-142)
11 =-51 1 (F=-256, B=-256) 12=-182(F=-91, B=-91)
Horz: 7=-218(F=-109, B=-109)
26) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
1st Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Vert: 1-3=80, 4-6=-10
Horz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-498(F=-249, B=-249)
10=-98(F=-49, B=-49)11=-381(F=-190, B=-190)
12=-9(F=-4, B=-4)
Horz: 7=-218(F=-109, B=-109)
27) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
2nd Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Vert: 1-3=47, 4-6=-10
Horz: 1-3=-57
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-405(F=-202, B=-202)
10=-98(F=-49, B=-49) 11=-381(F=-190, B=-190)
12=-9(F=4, B=-4)
Horz: 7=-218(F=-109, B=-109)
28) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
3rd Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Vert: 1-3=80, 4-6=-10
Horz: 1-3=-90
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-498(F=-249, B=-249)
10=-98(F=-49, B=-49) 11=-381(F=-190, B=-190)
12=-9(F=4, B=-4)
Horz: 7=-218(F=-109, B=-109)
29) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal)
4th Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Vert: 1-3=47, 4-6=-10
Horz: 1-3=-57
Concentrated Loads (lb)
Vert: 8=-53(F=-27, B=-27) 9=-405(F=-202, B=-202)
10=-98(F=-49, B=-49) 11=-381(F=-190, B=-190)
12=-9(F=4, B=-4)
Horz: 7=-218(F=-109, 8=-109)
30) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
1st Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Vert: 1-3=22, 4-6=-20
Horz: 1-3=-52
Job
Truss
Truss Type
Qty
Ply
72005
HRA
Diagonlal
Hip Girder
2
1
A0117260
Job Reference (optional)
a. izu s Nov iz zui i MI I eK Inoustnes, Inc. I nu May 3 0,9:15:07 2018 Page 3
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-18CUZ2QJt51QSXjCaKaOmuvRjr307TTJYNC�n1zKGVc
LOAD CASE(S)
Standard
Concentrated Loads (lb)
Vert: 8=-25(F=-12, B=-12) 9=-354(F=-177, B=-177)
11=-352(F=-176, B=-176) 12=-9(F=-4, B=-4)
Horz: 7=-218(F=-109, B=-109)
31) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal)
2nd Parallel: Lumber Increase=1.60, Plate
Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-10, 4-6=-20
Horz: 1-3=-20
Concentrated Loads (lb)
Vert: 8=-25(F=-12, B=-12) 9=-261(F=-130, B=-130)
11=-352(F=-176, B=-176) 12=-9(F=-4, B=-4)
Horz: 7=-218(F=-109, B=-109)
32) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60
, Plate Increase=1.60
Uniform Loads (plo
Vert: 1-3=-36, 4-6=26
Horz: 1-3=-39
Concentrated Loads (lb)
Vert: 8=-142(F=-71, B=-71) 9=-227(F=-114, B=-114)
11=-358(F=-179, B=-179) 12=-136(F=-68, B=-68)
Horz: 7=-218(F=-109, B=-109)
33) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) Right): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-54, 5-6=-20, 4-5=26
Horz: 1-3=-21
Concentrated Loads (lb)
Vert: 8=-99(F=-49, B=-49) 9=-176(F=-88, B=-88)
11=-347(F=-174, B=-174)12=-136(F=-68, B=-68)
Horz: 7=-218(F=-109, B=-109)
34) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) 1st Parallel): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-36, 4-6=-20
Horz: 1-3=-39
Concentrated Loads (lb)
Vert: 8=-99(F=-49, B=-49) 9=-227(F=-114, B=-114)
11=-228(F=-114, B=-114) 12=-7(F=-3, B=-3)
Horz: 7=-218(F=-109, B=-109)
35) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75(0.6
MWFRS Wind (Neg. Int) 2nd Parallel): Lumber
Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-3=-60, 4-6=-20
Horz:1-3=-15 -
Concentrated Loads (lb)
Vert: 8=-99(F=-49, B=-49) 9=-158(F=-79, B=-79)
11=-228(F=-114, B=-114) 12=-7(F=-3, B=-3)
Horz: 7=-218(F=109, B=-109)
Job
Truss
Truss Type
Qty
Ply
A0117253
72005
HJ27-3
Diagonal Hip Girder
1
1
Job Reference (optional)
O
Ann ni....
10')nl7 RA;T L, la.li .afriac Inr Thu Ma 3 �4:�0:18 0�8 Pane 1
Al Roof (fusses, FOR Pierce, FL rU-+U, ueslgn(wa 1 uuSS.wui
... ..-., ......---..............,,............ ...... ..... ....-� --.... _..___._ _a_.
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-RvFl7Y1 Al NbyZ6cb5rkEe7TOL3NXHUGONORZoSzKCBp
0- 4
3-7-13
0- 4
3-7-13
2.12 12
2
v
1
r,
+ o
STRAP TOP AND BOTTOM CHORD
WITH LSTA12 STRAP
m
B1
d
-
6x6 = 8
3x4 = �Q,
3
Q.
4
3-3-4
13
I 3-3-4
01-1'
Plate Offsets (X Y)— (1:0-6-3 Edgel
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft
Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.31
Vert(LL) -0.00 4 >999
360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.60
Vert(CT) 0.00 4 >999
240
BCLL 0.0 '
Rep Stress Incr NO
WB 0.00
Horz(CT) 0.01 2 n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 18 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
6) Hanger(s) or other
connection device(s) shall be
BOT CHORD 2x6 SP No.2
provided sufficient
io support concentrated load(s) 86
BRACING-
lb down and 157 lb
up at 1-5-0, and 86 lb down and
TOP CHORD
Structural wood sheathing directly applied or 3-7-13 oc
157 lb up at 1-5-0
design/selection of
on bottom chord. The
such connection device(s) is the
responsibility of others.
BOT CHORD
7) In the LOAD CASE(S)
section, loads applied to the
Rigid ceiling directly applied or 10-0-0 oc bracing.
face of the truss are
noted as front (F) or back (B).
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
LOAD CASE(S)
Standard
REACTIONS. (lb/size)
1) Dead + Roof Live
(balanced): Lumber Increase=1.25
2 = -172/Mechanical
Plate Increase—�1.25
3 = -938/Mechanical
Uniform Loads
(plf)
4 = 1680/0-8-0 (min. 0-2-0)
Vert: 1-2=-90, 3-5=-20
Max Horz
Concentrated Loads
(lb)
4 = 57(LC 4)
Vert: 8=-173(F=-86,
B=-86)
Max Uplift
2 =-172(LC 1)
3 =-938(LC 1)
4 =-1684(LC 4)
Max Grav
2 = 175(LC 4)
3 = 952(LC 8)
4 = 1680(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
Cantilever left exposed ; porch left exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 172 lb uplift at
joint 2, 938 lb uplift at joint 3 and 1684 lb uplift at joint 4.
Job
Truss
Truss Type
Qty
Ply
72005
HJ36
Diagonlal Hip Girder
4
1
A0117254
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@aitruss.com 8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 0,9:16:09 2018 Page 1
ID: nKMLCG99vHyLG9D5?YIAEyzKd3P-iXKF_kRZOj?8hgtbilcUrJ?u4fs5bOBc?hh}9rwzKGVa
-014-8 2-10-11 5-1-8
0-0-8 2-10-11 2-2-12
I
LOADING (psf)
SPACING-
2-0-0
TCLL
30.0
Plate Grip DOL
1.25
TCDL
15.0
Lumber DOL
1.25
BCLL
0.0 *
Rep Stress Incr
NO
BCDL
10.0
Code FBC2017/TP12014
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-1-8 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
-188/Mechanical
4 =
-268/Mechanical
5 =
829/0-11-5 (min. 0-1-8)
Max Horz
5 =
135(LC 4)
Max Uplift
3 =
-291(LC 19)
4 =
-335(LC 19)
5 =
-855(LC 4)
Max Grav
3 =
181(LC 22)
4 =
217(LC 22)
5 =
829(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
WEBS
2-5=-484/453
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left exposed ; porch left exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
3x6 II
4-10-
2-4-1
CSI.
DEFL. in
(loc)
I/deft
Ud
TC 0.39
Vert(LL) -0.01
4-5
>999
360
BC 0.37
Vert(CT) 0.01
4-5
>999
240
WB 0.06
Horz(CT) -0.03
3
n/a
n/a
Matrix -MP
15) Provide mechanical connection (by others) of truss
'to bearing plate capable of withstanding 100 lb uplift at
'joint(s) except (jt=lb) 3=291, 4=335, 5=855.
6) Hanger(s) or other connection device(s) shall be
i provided sufficient to support concentrated load(s) 168
;lb down and 209 lb up at 4-2-15, and 168 lb down and
' 209 lb up at 4-2-15 on top chord, and 84 lb down and
129 lb up at 1-5-0, 84 lb down and 129 lb up at 1-5-0,
and 168 lb down and 184 lb up at 4-2-15, and 168 lb
down and 184 lb up at 4-2-15 on bottom chord. The
' design/selection of such connection device(s) is the
responsibility of others.
7) In the LOAD CASE(S) section, loads,applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-90, 4-6=-20
Concentrated Loads (lb)
Vert: 8=-168(F=-84, B=-84) 9=172(F=86, B=86)
10=185(F=93,B=93)
PLATES GRIP
MT20 244/190
Weight: 27 lb FT = 10%
Job
Ai
Truss
Truss Type
Qty
Ply
A0117261
72005
J5
Jack -Open
4
1
'
Job Reference (optional)
., i-- "., —.. o ----
Al Koof Trusses, Fort Pierce, FL 34946, aesign@ai cruss.cum
" icu a ry i c w i . "' . cn u.w u.co n.... -.... -.........— —.. -..
I D:nKMLCG99vHyLG9D5?YIAEyzKd3P-iXKF_kRZOj?8hgtbilcUrJ?xxfvDbNTc?hh9rwzKGVa
00--
5-0-0
--66
5-0-0
3
5.00 12
2x4 II
12
T1
2-0-0
°0
Gp N
1
�
N
O
B1
6'
n
3x4
5
4
3x6 II
1-9-8
2-1 $
4-8-8
1-9-8
4-
2-7-0
3�
Plate Offsets (X Y)--
[5:0-4-4 0-1-8)
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL. in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.21
Vert(LL) -0.00
4-5
>999
360
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.17
Vert(CT) 0.00
4-5
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.10
Horz(CT) 0.01
3
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 26 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
3 = 74/Mechanical
4 = -10/Mechanical
5 = 483/0-8-0 (min.0-1-8)
Max Horz
5 = 185(LC 12)
Max Uplift
3 =-118(LC 12)
4 = -10(LC 1)
5 =-327(LC 8)
Max Grav
3 = 74(LC 1)
4 = 34(LC 10)
5 = 483(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-406/143
BOT CHORD
1-5=-145/401
WEBS
2-5=-336/822
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;C-C
for members and forces 8. MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) . This truss has
20.Opsf on the bott
rectangle 3-6-0 tall
bottom chord and
4) Refer to girder(s
5) Provide mechan
to bearing plate cal
joint(s) 4 except at -
LOAD CASE(S)
Standard
:en designed for a live load of
n chord in all areas where a
y 2-0-0 wide will fit between the
y other members.
or truss to truss connections.
al connection (by others) of truss
ible of withstanding 100 lb uplift at
)) 3=118, 5=327.
Job
Truss
Truss T
e
Qty
Ply
72005
J5A
Jack -Open
4
1
A0117262
Job Reference o tional
,�, r.avo, uca y� Ewa uuas.wm 6A20 s Nov iz Z01 / Mliek Industries, Inc. Thu May 3 09:16:10 2018 Pagel
I D:nKMLCG99vHyLG9D5?YIAEyzKd3P-AjudB4SB907?J_SnFS7jN WX7C2FnKrKmELQ)NMzKGVZ
3-2-8 +
3-2-8
5.00 Fl2
T
N
4x4 II
2-11-0 3-2-8
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL
1.25
1 TC 0.17
Vert(LL)
0.00
3-4
>999
360
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.15
Vert(CT)
-0.00
3-4
.>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB . 0.00
Horz(CT)
-0.01
2
n/a
n/a
BCDL 10.0
Code FBC2017(fP12014
Matrix -MR
Weight: 17 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 3-2-8 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
4 =
160/0-8-0 (min.0-1-8)
2 =
122/Mechanical
3 =
38/Mechanical
Max Horz
4 =
109(LC 12)
Max Uplift
4 =
-43(LC 12)
2 =
-143(LC 12)
3 =
-17(LC 12)
Max Grav
4 =
160(LC 1)
2 =
122(LC 1)
3 =
57(LC 3)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) 4, 3 except Qt=lb) 2=143.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
A0117263
72005
J5C
Jack -Open
5
1
'
Job Reference o tional
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com
1
8.120 s Nov 12 2U1 / Mi I ek Industries, inc. Thu May 3 09:16:1 O 20i8 rage i
ID: nKMLCG99vHyLG9D5?YIAEyzKd3P-AjudB4SB907?J—SnFS7jN WX3J25aKn9mELQjN MzKGVZ
-2-0-12
4-11-4
2-0-12
4-11-4
3
5.00
12
6x6
2
x4 112-0-12
O
1
r
v
v
1
2x4
0
c�
2
e ILJI
6 U8
I I 2x4 ,� 4
2-7-4 4-7-12 4�11,-4
2-7-4 2-0-8 0-3-8
Plate Offsets (X Y)— [2:0-2-12 0-3-12)
LOADING(psf)
SPACING- 2-0-0
CSL
DEFL. in (loc) I/defl
Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.42
Vert(LL) 0.09 5-6 >594
360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.80
Vert(CT) 0.09 5-6 >618
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.27
Horz(CT) -0.09 3 n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 42 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
NOTES-
BOT CHORD 2x6 SP No.2
*Except*
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
WEBS 2x6 SP No.2
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
W2: 2x4 No.3
Cat. 11; Exp D; Encl!, GCpi=0.18; MWFRS (envelope)
OTHERS 2x6 SP No.o. 2
and C-C Exterior(2) zone; cantilever left exposed ; end
BRACING-
vertical left exposed; porch left exposed;C-C for
CHORD
members and forc..�s & MWFRS for reactions shown;
Sc to all wood sheathing directly applied or4-11-4 oc
Lumber DOL=1.60 plate grip DOL=1.60
purlins, except end verticals.
2) This truss has been designed for a 10.0 psf bottom
Cceilliing RD
chord live load nonconcurrent with any other live
Rigid directly applied or 5-0-1 oc bracing.
loads.
MiTek recommends that Stabilizers and required
3) « This truss has been designed for a live load of
cross bracing be installed during truss erection, in
20.Opsf on the bottom chord in all areas where a
accordance with Stabilizer Installation guide.
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and aby other members.
REACTIONS. (lb/size)
4) Refer to girder(s) for truss to truss connections.
6 = 501/0-8-0 (min. 0-1-8)
5) Provide mechanical connection (by others) of truss
3 = 162/Mechanical
to bearing plate capable of withstanding 100 lb uplift at
4 = 46/Mechanical
joint(s) except Qt=1b) 6=411, 3=183, 4=232.
Max Horz
6 = 299(LC 9)
Max Uplift
LOAD CASE(S)
6 =-411(LC 8)
Standard
3 =-183(LC 12)
4 =-232(LC 9)
Max Grav
6 = 501(LC 1)
3 = 162(LC 1)
4 = 93(LC 3)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-6=-454/540
BOT CHORD
5-6=-682/318
WEBS
2-5=-419/898
Job
Truss
Truss Type
Qty
Ply
72005
R
Jack -Open
6
1
A0117265
Job Reference (optional)
g
a russ.com 8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:16:11 2018 Page 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-evR?PQTgwKFsw81_pAeywk4GgSbl3GMvS?AGwozKGVY
0-Q-6 7-0-0
0- -6 7-0-0
1-9-8
Offsets
3x6 11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.31
Vert(LL) 0.01
4-5
>999
360
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
1 BC 0.14
Vert(CT) -0.01
4-5
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.14
Horz(CT) -0.02
3
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 36 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation nuide.
REACTIONS. (lb/size)
3 =
173/Mechanical
4 =
38/Mechanical
5 =
555/0-8-0 (min.0-1-8)
Max Horz
5 =
260(LC 12)
Max Uplift
3 =
-208(LC 12)
4 =
-9(LC 12)
5 =
-329(LC 8)
Max Grav
3 =
173(LC 1)
4 =
77(LC 3)
5 =
555(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-612/221
BOT CHORD
1-5=-190/530
WEBS
2-5=-487/1125
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=S.Opsf; BCDL=5.Opsf; h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ;C-C
for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
15) Provide mechanical connection (by others) of truss
Ito bearing plate capable of withstanding 100 lb uplift at
joint(s) 4 except (jt=lb) 3=208, 5=329.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
A0117264
72005
J7-3
Jack -Open
6
1
Job Reference o tional
H7 Koor I fusses, rorr rlerce, rL J V. U,
�I0
3x4 =
6-8-8
LOADING (psf)
TCLL 30.0
TCDL 15.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TP12014
CSI.
TC 0.36
BC 0.34
WB 0.00
Matrix -MP
DEFL. in (loc) I/deft
Vert(LL) 0.02 3-4 >999
Vert(CT) 0.02 3-4 >999
Horz(CT) -0.01 2 n/a
L/d
360
240
n/a
LUMBER -
TOP CHORD 2x6 SP No.2
4) Refer to girder(- for truss to truss connections.
BOT CHORD 2x6 SP No.2
5) Provide mechanical connection (by others) of truss
BRACING -
to bearing plate capable of withstanding 100 lb uplift at
TOP C
Joint(-) except Qt=1ti) 2=184, 3=111, 4=638.
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOT CHORD
LOAD CASE(S)
Rigid ceiling directly applied or 10-0-0 oc bracing.
Standard
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 = 183/Mechanical
3 = 19/Mechanical
4 = 562/0-8-0 (min. 0-1-8)
Max Horz
4 = 156(LC 8)
Max Uplift
2 =-184(LC 12)
3 =-111(LC 9)
4 =-638(LC 8)
Max Grav
2 = 183(LC 1)
3 = 69(LC 3)
4 = 562(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown._
BOT CHORD
1-4=-114/317
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf, h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ; porch
left exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
ieNjYlcANt9BTxdQmstBolg3hfvgSFzKGVX
PLATES GRIP
MT20 244/190
Weight: 34 lb FT = 10%
Job
Truss
Truss Type
Qty
Ply
A0117266
72005
RA
Jack-Olpen
15
1
Job Reference (optional)
Al Roof Trusses, tort coerce, I-L 34946, design(a7altruss.com 8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:16:12 2018 Page 1
I D: nKM LCG99vHyLG9D5?YIAEyzKd3 P-66?NcmTSheNjYlcANt9BTxdQ8su4ok43hfv4SFzKGVX
0-9-6 7-0-0
6 7-0-0
5.00 12
3x6 II 1
2
2-0.0 �.
i
o B1
O rid
0
a+ '
I
3x4 = 5 4
3x6
1-9-8
4-5-0
0-3-8
Plate Offsets (X,Y)—
[5:0-4-4,0-1-81
_..'0-6-0'
._....._......................_......._.
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc)
I/deft Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC
0.34
Vert(LL) 0.03
4-5
>999 360
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
BC
0.29
Vert(CT) 0.03
4-5
>999 240
BCLL 0.0
Rep Stress Incr
YES
WB
0.11
Horz(CT) -0.02
3
n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 36 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
puriins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
161/Mechanical
4 =
30/Mechanical
5 =
575/1-0-0 (min.0-1-8)
Max Horz
5 =
260(LC 12)
Max Uplift
3 =
-201(LC 12)
4 =
-130(LC 9)
5 =
-494(LC 8)
Max Grav
3 =
161(LC 1)
4 =
70(LC 3)
5 =
575(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-528/223
BOT CHORD
1-5=-190/530
WEBS
2-5=-505/895
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left exposed ; porch
left exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
3) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except (jt=1b) 3=201, 4=130, 5=494.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
A0117267
72005
J7B
Jack -Open
1
1
�
Job Reference (optional)
Al Koor I m55e5, rurr rierce, rL .Yfa40, Ue51y[QWU RIUSs.W1II
I D:nKMLCG99vHyLG9D5?YIAEyzKd3P-alZIp6U4SxVaASBMxagQ?99ZXGDuXC3CwJfN_hzKGV W
5-2-8
5-2-8
�.00 12
3x6 11
1
s s
B g
4
4x6 =
2
LOADING (psf)
TCLL 30.0
TCDL 15.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017(rP12014
CSI.
TC 0.49
BC 0.38
WB 0.00
Matrix -MR
DEFL. in (loc) I/deft
Vert(LL) 0.03 3-4 >999
Vert(CT) 0.03 3-4 >999
Horz(CT) -0.04 2 n/a
Ud
360
240
n/a
LUMBER -
TOP CHORD 2x6 SP No.2
5) Provide mechanical
connection (by others) of truss
BOT CHORD 2x6 SP No.2
to bearing plate ca
able of withstanding 100 lb uplift at
WEBS 2x6 SP No.2
joint(s) 4, 3 except
Qt=1b) 2=225.
BRACING-
TOP CHORD
Structural wood sheathing directly applied or 5-2-8 oc
LOAD CASE(S)
purlins, except end verticals.
Standard
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
4 =
270/0-8-0 (min. 0-1-8)
2 =
203/Mechanical
3 =
67/Mechanical
Max Horz
4 =
183(LC 12)
Max Uplift
4 =
-97(LC 12)
2 =
-225(LC 12)
3 =
-20(LC 12)
Max Grav
4 =
270(LC 1)
2 =
203(LC 1)
3 =
97(LC 3)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-4=-239/386
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=S.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) " This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
PLATES GRIP
MT20 244/190
Weight: 27 lb FT = 10%
Job
Truss
Truss Ty
a
Qty
Ply
72005
MHV2
Valley
2
1
A0117272
Al Roof Trusses. Fort Pierce_FI
14g4e ri—inn(nhif,—,.,,..,
Job Reference (optional)
V
n
0
, ninon muusuw , mc. - r nu may a j:76:9J zu18 Page 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-aIZIp6U4SxVaASBMxagQ?99fpG bXC3CwJfq hzKGVW
1-11-0 2,0,0
3x4
1-8-8
5.00 12
2
3
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc)
I/defi
L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.09
Vert(LL) 0.00 2
n/r
90
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.20
Vert(CT) -0.00 1
n/r
80
BCLL 0.0
Rep Stress Incr YES
, WB 0.00
Horz(CT) 0.00
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
I Matrix-P
Weight: 6 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x4 SP No.2
I
BRACING-
LOAD CASE(S)
TOP CHORD
Standard
Structural wood sheathing directly applied or 2-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 = 58/1-11-6 (min.0-1-8)
3 = 54/1-11-6 (min.0-1-8)
Max Horz
1 = 46(LC 9)
Max Uplift
1 = -38(LC 9)
3 = -52(LC 9)
Max Grav
1 = 58(LC 1)
3 = 54(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf, h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 100 lb uplift at
joint(s) 1, 3.
Job
Truss
Truss Type
Qty
Ply
A0117273
72005
MHV8
Valley
1
1
Job Reference (optional)
Al Root I cusses, Tort Tierce, FL 34u4o, oesignLairruss.com
1
5x6
ID:nKMLCG99vHyLG9D5?Y]AEWz d3P-2U781SViDFdRnblYUICtYMihpgcvGdML9zOwW7zKGW
8-0-0 ,
1-1-R
5.00 12
B1
4x6 11
2
5
3x8 II
T2
2x4 11
3
42x4 II
0- 10 16-10-8
0- -10 16-9-14
l-8-8 -U-
0-10-0 -3-
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.65
Vert(LL) n/a - n/a 999
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.14
Vert(CT) n/a - n/a 999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.19
Horz(CT) -0.00 4 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-P
Weight: 41 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
1 = 311/7-11-6 (min. 0-1-8)
4 =-38/7-11-6 (min. 0-1-8)
5 = 465/7-11-6 (min.0-1-8)
Max Horz
1 = 215(LC 12)
Max Uplift
1 =-167(LC 12)
4 =-150(LC 3)
5 =-203(LC 12)
Max Grav
1 = 311(LC 1)
5 = 465(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
WEBS
2-5=-328/635
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf, BCDL=5.Opsf; h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
c
6) Provide mechar)ical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except Qt=1p) 1=167, 4=150, 5=203.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
72005
MHV10
Valley
1
1
A0117268
Al P—I'T...... F=-A D;.--
CA gAnAn ,,,...:,....;.,..,........
___
Job Reference o tional
---- ou ica, 111- niu rviay oua: i¢ia zu io rages
ID: nKMLCG99vHyLG9D5?YIAEyzKd3P-W hhWEo W K_Zm IPI K12?ju4aFwA3ig?3dVNc8U3azKGVU
6-10-8 10-0-0 '
6-10-8 3-1-8
5x6
2
2x4 II
3
4x4 4
3x6 111 2x4 11
10 1 6-10-8 9-8-8 1 -0 0
002112
0 -10 1 6-9-14 2-10-0 -3-
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.42
Vert(LL) n/a - n/a 999
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.17
Vert(CT) n/a - n/a 999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.25
Horz(CT) -0.00 4 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-S
Weight: 51 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 =
28819-11-6 (min. 0-1-8)
4 =
83/9-11-6 (min. 0-1-8)
5 =
586/9-11-6 (min. 0-1-8)
Max Horz
1 =
215(LC 12)
Max Uplift
1 =
-139(LC 12)
4 =
-74(LC 8)
5 =
-361(LC 12)
Max Grav
1 =
288(LC 1)
4 =
83(LC 1)
5 =
586(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
WEBS
2-5=-447/850
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf, h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Extedor(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
1
5) ' This truss has been designed for a live load of
20.0psf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) 4 except Qt=lb) 1=139, 5=361.
I
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
A0117269
72005
MHV12
Valley
1
T
Job Reference (optional)
Al Moor i tosses, tort rlerce, M J4a4o, aesign�wa i uuss.wm
6-10-8
5.00 F12
4x4
I D:nKMLCG99vHyLG9D5?YIAEWKd3P-W hhW EoWK_Zm IPIKI2?ju4aFxg3yv?2NVNc8U3azKGVU
12-0-0
B1
5x6
2
5
3x6 11
T2
LOADING (psf)
SPACING-
2-0-0
CS'-
DEFL.
in (loc)
I/deft
L/d
TCLL 30.0
Plate Grip DOL
1.25
TC 0.38
Vert(LL)
n/a -
n/a
999
TCDL 15.0
Lumber DOL
1.25
BC 0.15
Vert(CT)
n/a -
n/a
999
BCLL 0.0
Rep Stress Incr
YES
WB 0.27
Horz(CT)
-0.00 4
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-S
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 =
293/11-11-6 (min. 0-1-8)
4 =
229/11-11-6 (min.0-1-8)
5 =
655/11-11-6 (min.0-1-8)
Max Horz
1 =
215(LC 12)
Max Uplift
1 =
-143(LC 12)
4 =
-159(LC 8)
5 =
-369(LC 12)
Max Grav
1 =
293(LC 1)
4 =
229(LC 1)
5 =
655(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
3-4=-198/312
WEBS
2-5=-504/904
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
5)' This truss has lbeen designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechariical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except Qt=1b) 1=143, 4=159, 5=369.
LOAD CASE(S)
Standard
2x4 II
3
42x4 II
PLATES GRIP
MT20 2441190
Weight: 60 lb FT = 10%
Job
Truss
Truss Type
Qty
Ply
72005
MHV14
Valley
1
1
A0117270
Job Reference (optional)
-----•----------•-- --- -•---� `-'-•••_--•---••• U.—a i.w 14—i1-11 en uMubuies, inc. rnu May S zulB Yagel
I D: nKMLCG99vHyLG9D5?YIAEyzKd3P-?tFuS7Xylsu9l vvxcjE7dnn2gTlgkVHecG41 bOzKGVT
6-10-8 14-0-0
6-10-8 7_1.8
4x4
0
5.00 12
6x6 =
2
5
3x8 II
4x6 II
3
43x6 II
LOADING(psf)
SPACING- 2-0-0
CS'-
DEFL. in (loc) 1/defl Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL 10
TC 0.61
Vert(LL) n/a - n/a 999
MT20 2441190
TCDL 15.0
Lumber DOL 1.25
BC 0.18
Vert(CT) n/a - n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.29
Horz(CT) -0.00 4 n/a n/a
BCDL 10.0
Code FBC20171TPI2014
Matrix-S
Weight: 70 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 =
295/13-11-6 (min. 0-1-10)
4 =
352/13-11-6 (min. 0-1-10)
5 =
750/13-11-6 (min. 0-1-10)
Max Horz
1 =
215(LC 12)
Max Uplift
1 =
-148(LC 12)
4 =
-235(LC 8)
5 =
-417(LC 9)
Max Grav
1 =
295(LC 1)
4 =
352(LC 1)
5 =
750(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
3-4=-295/438
WEBS
2-5=-583/977
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=S.Opsf; BCDL=S.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of
20.0psf on the bottom chord in all areas where a
'rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
�6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except Qt=lb)1=148, 4=235, 5=417.
'LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
AO117271
72005
141HV16
Valley
1
1
rt
Job Reference o tional
Al Koor 1 russes, rOrr vierce, rL AU'+0, aeslyn�(V 1 uuss.wln
v
Cil
5x6
2
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-?tFuS7Xylsu9l vvxcjE7dnn61TIEkW PecGtl bOzKGVT
11-5-4 1 16-0-0 1
2x4 II
3
2x4 If
4
4x4 7�:7 7 1 6 b
2x4 11 2x4 11 2x4 11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
Ud
TCLL 30.0
Plate Grip DOL
1.25
TC 0.36
Vert(LL)
n/a -
n/a
999
TCDL 15.0
Lumber DOL
1.25
BC 0.14
Vert(CT)
n/a -
n/a
999
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.22
Horz(CT)
-0.00 5
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-S
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. All bearings 15-11-6.
(lb) - Max Horz
1= 215(LC 12)
Max Uplift
All uplift 100 lb or less at joint(s)
except 1=-143(LC 12), 5=-126(LC 9),
7=-354(LC 12), 6=-350(LC 8)
Max Grav
All reactions 250 lb or less at joint(s)
5 except 1=295(LC 1), 7=592(LC 1),
6=526(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
WEBS
2-7=-449/734, 3-6=-449/621
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 143 lb uplift at
joint 1, 126 lb uplift at joint 5, 354 lb uplift at joint 7 and
350 lb uplift at joint 6.
LOAD CASE(S)
Standard
PLATES GRIP
MT20 244/190
Weight: 82 lb FT = 10%
11 uss i russ rype Qty Ply
72005 MV2 Valley i 1 1
Job Refer,
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com 8.120 s Nov 12 2017 1
I D:n KMLCG99vHyLG9D5?YIAEyzKd3P-
2-0-0
2-0-0
5.00 12
2
9
I 3x4 --
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
L/d
TCLL 30.0
Plate Grip DOL
1.25
TC 0.02
Vert(LL)
n/a -
n/a
999
TCDL 15.0
Lumber DOL
1.25
BC 0.01
Vert(CT)
n/a -
n/a
999
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00 2
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-P
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x4 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-0-0 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 = 58/1-11-6 (min.0-1-8)
2 = 47/1-11-6 (min.0-1-8)
3 = 11/1-11-6 (min.0-1-8)
Max Horz
1 = 39(LC 12)
Max Uplift
1 = -28(LC 12)
2 = -50(LC 12)
Max Grav
1 = 58(LC 1)
2 = 47(LC 1)
3 = 21(LC 3)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf, h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
4)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Bearing atjoint(s) 2 considers parallel to grain value
using ANSI/fPI 1 angle to grain formula. Building
designer should verify capacity of bearing surface.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 28 lb uplift at
joint 1 and 50 lb uplift at joint 2.
LOAD CASE(S)
Standard
AO117275
Inc. Thu May 3 0r9:16:17 2018 Page 1
PLATES GRIP
MT20 244/190
Weight: 6 lb FT = 10%
Job
Truss
Truss Type
Qty
Ply
A0117277
72005
MV4
Valley
3
1
�
Job Reference (optional)
Al moor r russes, rOrL YrerCe, rL aydyo, uesrgri wd muss.wm
Y
n
0
3x4
I D: n KM LCG99vHyLG9D5?YIAEyzKd 3P-T3pGf TXaWA00e3U7AQl MA?KKjtg8T03orwd b7SzKGVS
3-7-14
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.16
Vert(LL) n/a - n/a 999
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.04
Vert(CT) n/a - n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00 2 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-P
Weight: 16 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 4-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
1 =
157/3-11-6 (min. 0-1-8)
2 =
128/3-11-6 (min. 0-1-8)
3 =
28/3-11-6 (min.0-1-8)
Max Horz
1 =
106(LC 12)
Max Uplift
1 =
-77(LC 12)
2 =
-135(LC 12)
Max Grav
1 =
157(LC 1)
2 =
128(LC 1)
3 =
57(LC 3)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf, BCDL=5.Opsf; h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2)'zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Bearing atjoint(s) 2 considers parallel to grain value
using ANSI/TPI 1 angle to grain formula. Building
designer should verify capacity of bearing surface.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 77 lb uplift at
joint 1 and 135 lb uplift at joint 2.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
ply
72005
MV6
Valley'
3
1
A0117278
Al 0....F T........... C—o:--....
-----
____ I
Job Reference (optional)
• - ---- -- --• - - - - -•------- u. �w a rvvv is cv i mi icn lRUU5Ine5, Inc. . nu May 6 ujv:lt7:iu zu7S Yage 1
6-0-0
ID: nKMLCG99vHyLG9D5?YIAEyzKd3P-xGNetpYDHU8tGD3Kj8GbiCtQgH?CCTJx3aK8guzKGVR
6-0-0
3x6 11
2
4x4
3x6 11
5-8-8
5-7-14
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL. in floc) I/deft Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.45
Vert(LL) n/a - n/a 999
MT20 244/190
TCDL 15:0
Lumber DOL 1.25
BC 0.11
Vert(CT) n/a - n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-P
Weight: 28 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 LOAD CASE(S)
BRACING- Standard
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 cc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 = 259/5-11-6 (min.0-1-8)
3 = 259/5-11-6 (min. 0-1-8)
Max Horz
1 = 176(LC 12)
Max Uplift
1 =-127(LC 12)
3 =-200(LC 12)
Max Grav
1 = 259(LC 1)
3 = 259(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-259/500
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=S.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 127 lb uplift at
joint 1 and 200 lb uplift at joint 3.
Job
Truss
Truss Type
Qty
Ply
A0117279
72005 ,;
MVS
Valley I
2
1
Job Reference o tional
Al Root I cusses, 1-Ort merce, M 340140, 0e51gn(aaa i IrUSS.UU111
6x6
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-xGNetpYDHU8tGD3Kj8GbiCtJfHzACTJx3aM8guzKGVR
8-0-0
8-0-0
5.00 12
7-8-8
7-7-14
3x8 11
2
33x8 11
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.91
Vert(LL) n/a - n/a 999
MT20 2441190
TCDL 15.0
Lumber DOL 1.25
BC 0.24
Vert(CT) n/a - n/a 999
BCLL 00 '
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00 n/a n/a
BCDL 10.0
Code FBC20171TP12014
Matrix-P
Weight: 39 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 LOAD CASE(S)
BRACING- Standard
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (lb/size)
1 =
369/7-11-6 (min.0-1-8)
3 =
369/7-11-6 (min.0-1-8)
Max Horz
1 =
250(LC 12)
Max Uplift
1 =
-181(LC 12)
3 =
-285(LC 12)
Max Grav
1 =
369(LC 1)
3 =
369(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-278/127, 2-3=-350/662
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf, BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces R
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
4)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 181 lb uplift at
joint 1 and 285 lb uplift at joint 3.
Job
Truss
Truss Type
Qty
Ply
72005
MV10
Valley
2
1
A0117274
Job Reference (optional)
n i r�uu� i i wa , -ui i ricn.c, r� ora�u, ucaiyl i�wa 1 u u55.wn I
v
0
0
3x4 5
3x8 11
i
9
O. 14U 5 IVUV' I L GU 1 / IVII I eK IrIUUSIneS, Inc. I nu may a Lhu:IO:-i u zu70 rage i
3
4 3x6 11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in (loc)
I/defl
Ud
TCLL 30.0
Plate Grip DOL
1.25
TC 0.36
Vert(LL) n/a -
n/a
999
TCDL 15.0
Lumber DOL
1.25
BC 0.09
Vert(CT) n/a -
n/a
999
BCLL 0.0
Rep Stress Incr
YES
WB 0.30
Horz(CT) -0.00 4
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-S
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-M oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 =
109/9-11-6 (min.0-1-8)
4 =
242/9-11-6 (min.0-1-8)
5 =
605/9-11-6 (min.0-1-8)
Max Horz
1 =
325(LC 12)
Max Uplift
4 =
-188(LC 12)
5 =
-467(LC 12)
Max Grav
1 =
109(LC 1)
4 =
242(LC 1)
5 =
605(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-561/219, 3-4=-217/407
WEBS
2-5=-547/1021
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
1 4) " This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 188 lb uplift at
joint 4 and 467 lb uplift at joint 5.
LOAD CASE(S)
Standard
PLATES GRIP
MT20 244/190
Weight: 52 lb FT = 10%
Job
Truss
Truss Type
Qty
Ply
A0117276
72005
MV26
Valley
2
1
Job Reference (optional)
Al KOOT I rUS5e5, I -OR t-ICUCO, r•L 8 U40, UU51YI]Md ILIU55.W-
.—y �..... ..-y.. .
ID:nKMLCG99vHyLG9D5?YIAEy Kd3P-PSwO49Zr2nGkuNeWHmgFQPi7hL3xwZ51E6hCLzKGVQ
3x4
3
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defi L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.03
Vert(LL) n/a - n/a 999
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.01
Vert(CT) n/a - n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00 2 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-P
Weight: 9 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-6-4 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 =
75/2-5-10 (min. 0-1-8)
2 =
61/2-5-10 (min.0-1-8)
3 =
14/2-5-10 (min.0-1-8)
Max Horz
1 =
51(LC 12)
Max Uplift
1 =
-37(LC 12)
2 =
-65(LC 12)
Max Grav
1 =
75(LC 1)
2 =
61(LC 1)
3 =
27(LC 3)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
4) . This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Bearing at joint(s) 2 considers parallel to grain value
using ANSI/TPI 1 angle to grain formula. Building
designer should verify capacity of bearing surface.
6) Provide mechanical connection (by others) of truss
to bearing plate caQable of withstanding 37 lb uplift at
joint 1 and 65 lb uplift at joint 2.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
72005
V4
Valley '
1
1
A0117282
Job Reference (optional)
Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com 8.120 s Nov 12 2017 MiTek Industries, Inc. Thu May 3 09:16:20 2018 Page 1
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-teUPHVaTp5OaVWDirZl3ndyte4hZgNoEXur: knzKGVP
2-0-0 4-0-0
-0-0 2-0-0
3x4
5.00 12 2 4x4 =
3-8-8
3x4
0-3-8
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.05
Vert(LL) n/a - n/a 999
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.06
Vert(CT) n/a - n/a 999
BCLL 0.0 *
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00 3 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-P
Weight: 12 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x4 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 4-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 =
116/3-10-13 (min.0-1-8)
3 =
'116/3-10-13 (min. 0-1-8)
Max Horz
1 =
-14(LC 13)
Max Uplift
1 =
-63(LC 12)
3 =
-63(LC 13)
Max Grav
1 =
116(LC 1)
3 =
116(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-142/253, 2-3=-142/253
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 63 Ib uplift at
joint 1 and 63 lb uplift at joint 3.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Qty
Ply
A0117283
72005
V8
Valley
1
1
Job Reference (optional)
Al Floor I cusses, I-ort coerce, r-L 34U4b, oeslgn(ga"Irruss.com
v
Q
a
0
4x4 � 3x4
5.00 F12
o..< .rvw cu ii "' i cn inuuouw, on..
ID:nKMLCG99vHyLG9D5?YIAEyzKd3P-teUPHVaTp5OaV WDirZl3ndyg34fXgNoEXurFknzKGVP
8-0-0
4-0-0
4x4 =
2
B1
3x4 -- 4x4
3
0- -10
1 7-7-14 0-3-6
Plate Offsets (X Y)— [1:0-1-13 Edge] [3:0-6-13 Edgel
I
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC 0.21
Vert(LL) n/a - n/a 999
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.19
Vert(CT) n/a - n/a 999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00 3 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-P
Weight: 33 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 = 313/7-10-13 (min.0-1-8)
3 = 313/7-10-13 (min.0-1-8)
Max Horz
1 = 39(LC 16)
Max Uplift
1 =-170(LC 12)
3 =-170(LC 13)
Max Grav
1 = 313(LC 1)
3 = 313(LC 1)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
1-2=-372/621, 2-3=-372/621
BOT CHORD
1-3=-464/306
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.Opsf; h=39ft;
Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
5) ` This truss hasi been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and tany other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 170 lb uplift at
joint 1 and 170 lb uplift at joint 3.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Oty
Ply
72005
V12
Valley
1
1
A0117280
AlRn.,f Tn�c�nc G..ti ote...,,
n ann�c a....:....�
Job Reference (optional)
-- --• - - - - -• --- �• �-.-- • •• •---•w• • • O- I zU s rvuv I c w I / mi i eK maus[nes, mc. i nu may J U9:15:21 Zola Pagel
ID:nKMLCG99vHyLG9D57YIAEyzKd3P-L2nVra5aPWR7govPGglKrV vUOzPo4NmYbpRGDzKGVO
6-0-0 12-0-0
6-0-0 6-0-0
4x6 =
4x4 i�- 3x4 4
2x4 11 3x4 -- 4x4
0- 10 1 11-8-8 1 -0 0
0- -10 11-7-14 _g_
Plate Offsets (x.Y)- r1:0-1-13_FdnPl r3•n-R-13 Frinat
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc) I/defl
L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL
1.25
I TC 0.27
Vert(LL)
n/a
- n/a
999
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.11
Vert(CT)
n/a
- n/a
999
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.19
Horz(CT)
0.00
3' n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-S
Weight: 55 lb FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
OTHERS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 =
245/11-10-13 (min.0-1-8)
3 =
245/11-10-13 (min.0-1-8)
4 =
576/11-10-13 (min.0-1-8)
Max Horz
1 =
67(LC 16)
Max Uplift
1 =
-162(LC 12)
3 =
-173(LC 13)
4 =
-255(LC 12)
Max Grav
1 =
249(LC 23)
3 =
249(LC 24)
4. =
576(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
WEBS
2-4=-420/641
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf, BCDL=5.Opsf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live Joads.
5) . This truss has been designed for a live load of
20.0psf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 162 lb uplift at
jI oint 1, 173 lb uplift at joint 3 and 255 lb uplift at joint 4.
LOAD CASE(S)
Standard
I
Job
Truss
Truss Type
Qty
Ply
I
AO117281
72005
V16
Valley
1
1
Job Reference o tional
Al ROOT I russes, tort Fierce, tL i4`J4b, aesignLa-nruss.cwm
8-0-0
6x6 =
N
5.00 12
O. I LU S IVVv 14 4V I / IVII I GIB IIIU UJU IGJ, II Iv. 1 vl y ray. 1
vHyLG9D5?YIAEyzKd3P-p1 c9iBbjKiellgN5yzLXt214uuKX8ESX_CKMpgzKGVN
3
..
o
�
5x6
4.
5x6
3x6 11
0- 10
15-8-8
1 - 0
0- -10
1 15-7-14
-3-8
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defl
L/d
PLATES
GRIP
TCLL
30.0
Plate Grip DOL
1.25
TC 0.51
Vert(LL)
n/a -
n/a
999
MT20
244/190
TCDL
15.0
Lumber DOL
1.25
BC 0.22
Vert(CT)
n/a -
n/a
999
BCLL
0.0 '
Rep Stress Incr
YES
WB 0.25
Horz(CT)
0.00 3
n/a
n/a
BCDL
10.0
Code FBC2017/TP12014
Matrix-S
Weight: 75 lb
FT = 10%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
OTHERS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 = 346/15-10-13 (min. 0-1-12)
3 = 346/15-10-13 (min. 0-1-12)
4 = 813/15-10-13 (min. 0-1-12)
Max Horz
1 = -94(LC 17)
Max Uplift
1 =-229(LC 12)
3 =-245(LC 13)
4 =-361(LC 12)
Max Grav
1 = 351(LC 23)
3 = 351(LC 24)
4 = 813(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
WEBS
2-4=-595/827
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust)
Vasd=139mph; TCDL=5.Opsf; BCDL=5.0psf; h=39ft;
Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
5) * This truss has peen designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 talllby 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechan'cal connection (by others) of truss
to bearing plate capable of withstanding 229 lb uplift at
joint 1, 245 lb upliftlat joint 3 and 361 lb uplift at joint 4.
LOAD CASE(S)
Standard
JAN UARY 17, 2017
TYPICAL HIP / KING JACK CONNECTION I STDTLOI
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
CORNERSET GENERAL SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 175 mph, ASCE
7-10, Exp. B, C up to 60' Mean Roof Height
and Exposure D up to 30' Mean Roof Height.
Attach End Jack's
w/ (4) 16d Toe Nails @ TC
& (3) 16d Toe Nails @ BC
mbolli;Pl RdPted9ApalMs
Attach King Jack w/ (3) 16d Toe
,Nails @ TC & 24" Strap w/ (6)
1Od x 1.5" ea. end @ BC
Attach Corner Jack's
x w/ (2) 16d Toe Nails @ TC &
BC (Typ)
0
ti
3ch Corner Jack's
(2) 16d Toe Nails
TC & BC (Typ)
*t$an Pe mhsiee (Im fl ta¢!iiesses, Ardeay' P, Terbe €€L P1
Antfiang'T;''1'om5o iil; P:�,
80083
4451 St. Lucie B!v&
Fort Pierce, FL 34946'
FEBRUARY 17, 2017
ALTERNATE
A-1 ROOF TRUSSES r
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010 1' - 3' MAX.
DIAG. BRACE
AT 1/3 POINTS
IF NEEDED
IT IS THE RESPONSIBILITY OF THE BLDG.
DESIGNER OR THE PROJECT ENGINEER/ARCHITECT
TO DESIGN THE CEILING DIAPHRAGM AND ITS
ATTACHMENT TO THE TRUSSES TO RESIST ALL
OUT OF PLANE LOADS THAT MAY RESULT FROM
THE BRACING OF THE GABLE ENDS.
END BRACING DETAIL
ONTAL BRACE
SECTION A -A)
TRUSSSES @
F_ 24' O.C.
STDTL03
2XG DIAGONAL BRACE SPACED 48'
O.C. ATTACHED TO VERTICAL WITH
(4) - 16d NAILS, AND ATTACHED TO
BLOCKING WITH (5) - lOd COMMONS.
NAIL DIAGONAL BRACE TO
PURLIN WITH TWO 16d NAILS.
2X4 PURLIN FASTENED TO FOUR
TRUSSES WITH (2) - 16d NAILS
EACH. FASTEN PURLIN TO BLOCKING
W/ (2) - 16d NAILS (MIND.
PROVIDE 2X4 BLOCKING BETWEEN
THE TRUSSES SUPPORTING THE
\BRACE AND THE TWO TRUSSES ON
\EITHER SIDE AS NOTED. TOENAIL
\BLOCKING TO TRUSSES WITH (2) -
\ 10d NAILS AT EACH END. ATTACH
DIAGONAL BRACE TO BLOCKING WITH
(5) - 10d COMMON WIRE NAILS.
WALL
CEILING SHEATHING
STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED:
METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE
OF THE STRUCTURAL GABLE AND FASTEN PER THE
FOLLOWING NAIL SCHEDULE.
METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL
MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING
NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG
SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL
NAILING SCHEDULE:
- FOR WIND SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE
7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131
X 3') NAILS SPACED G' O.C.
- FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-9B, 02, 05), 150
MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d
(.131'X3') NAILS SPACED G' O.C. (2X4 STUDS MINIMUM).
STRUCTURAL
GABLE TRUSS
MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI
BRACING METHODS SHOWN ON PAGE 1 ARE VALID
AND ARE TO;BE FASTENED TO THE SCABS OR
VERTICAL STUDS OF THE STANDARD GABLE TRUSS
ON THE INTERIOR SIDE OF THE STRUCTURE.
I i
NOTE. THIS DETAIL IS TO BE USED ONLY FOR/
STRUCTURAL GABLES WITH INLAYED
STUDS. TRUSSES WITHOUT INLAYED
STUDS ARE NOT AODRESSEDIHERE.
I[,
STANDARD GABLE I
--- I-URAL
TRUSS
:TI In
AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING
MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF
THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS.
THE BRACING SHOWN IN THIS DETAIL IS FOR
VERTICAL/STUDS ONLY.
, , 2017
STANDARD
CONN
PIGGYBACK TRUSS
-r-rinm DETAIL_-
S►UILU�+
A-1 ROOF TRUSSES
4451 Sr. LUCIE BLVD.
FORT 7FL g046
72A09-1010
THIS DETAIL IS APPLICABLE FOR THE FOLLOWING WIND CONDITIONS:
UPLIFT EXCEEDS 377 LBS. REFER TO ACTUAL PIGGYBACK TRUSS DESIGN
ASCE 7-98, ASCE 7-02, ASCE 7-05, ASCE 7-10 WIND STANDARDS UNDER ALL ENCLOSURE AND EXPOSURE
CONDITIONS
FOR UPLIFTS- NG S NO
VALID FOR ONE PLY TRUSSES SPACED 24" O.C. OR LESS;
NOTE: THIS DETAIL IS
PIGGYBACK TRUSS
REFER
FOR
ADDIT ADDITIONAL PIGGYBACK TRUSS NG N ORIMATION'
i
SPACE PURLINS ACCORDING TO THE MAXIMUM
SP(SPACING NOT TO EXCEED 24 O.CJ A PURLIN THE BASE TRUSS
TO BE LOCATED AT EACH BASE TRUSS JOINT.
ATTACH PIGGYBACK TRUSS TO THE BASE TRUSS WITH 2" X 8"
TEE -LOCK MULTI -USE CONNECTION PLATES SPACED 48" O.C. PLATES
SHALL BE PRESSED INTO THE PIGGYBACK TRUSS E A O.C.
STAGGERED FROM EACH FACE AND NAILED TO THE BASE TRUSS WITH
FOUR
UPLIFT CAPACITY OF 377 LBS. AT EACH 2PX 8 TEE -LOCK MU
LAT LTII- TO ACHIEVE A AUSE UM
U
CONNECTION PLATE. (MINIMUM OF 2 PLATES
ATTACH EACH PURLIN TO THE TOP CHORD OF
THE BASE TRUSS.
(PURLINS AND CONNECTION BY OTHERS)
BASE TRUSS
ADDITITO ACTUAL TRUSS DESIGN DRAW
ONAL BASE TRUSS NFORMAT ON ING FOR
Aitfnvn!T TaAJOI'll .P.E.
4 90053',
4451 St: Eu�ie. 8lyd:
Fort Fjet, I L 34946;
OEYKun"�eu+ f tts SOYt t' -- s Rlt�rt �"'
Cl y+lwry�'. flfLftN641irL
,rMeP'.uf�df,fSf�it!R?�'ama iaa�Lt si3YYYe 4rk1d. 7pattass
• tnenidti92i�i6blidci ass s Adttocgl ideiEoUiti.E::1i��ett.dao-tttiti
JULY 17, 2017 I TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05
GENERAL SPECIFICATIONS:
�I 1. NAIL SIZE = 3" X 0.131" = 10d
2. WOOD SCREW = 4.5" WS45 USP OR EQUIVALENT.
3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES.
4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND
SECURE TO BASE TRUSSES AS PER DETAIL "A".
5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE
INDIVIDUAL DESIGN DRAWINGS.
— ----.._..—..._._..._!w�rl
6. NAILING DONE PER NDS - 01.
A-1 ROOF TRUSSES 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
4451 ST. LUCIE BLVD. GABLE END, COMMON
FORT PIERCE, FL 34946 TRUSS, OR GIRDER
772-409-1010 TRUSS
VALLEY TRUSS
(TYPICAL)
P 12
SECURE VALLEY TRUSS
W/ ONE ROW OF 10d
NAILS 6" O.C.
SEE DETAIL)"A"
BELOW (TYP.)
BASE TRUSSES
VALLEY TRUSS
(TYPICAL)
ATTACH 2X4 CONTINUOUS #2
SYP TO THE ROOF W/ TWO USP
WS45 (1/4" X 4.5") WOOD SCREWS
INTO EACH BASE TRUSS.
DETAIL A
TRUSS CRITERIA:
I
GABLE END; COMMON
TRUSS, OR GIRDER TRUSS
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD = 50 PSF
MAX SPACING = 24" O.C. (BASE AND VALLEY)
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
us[tq �wztttui:lp;t,a«eF afl�Dt'Wiflti""'(fl'j,EiMi4s iC&ki6t0ldtkt".1t£Li9NCi�"i°; {Ra9at«GESt`f'ra taa d,>,aaaie:;:sattrilggt��ss sasest�®.ray DOj�tltty�.J��'a@P,t[ttt•t�rV�eisfir c �)nse,.eir,as�+dd.,DU;tatr
:�"3ffk:ir tgBSSej Se l:dG9rtit7§613i$f[a# ftt Ttffi4:Sssui¢jttFU.;iM1ti`{(NdMP/41t9Si xrmrd6kE[!kveY>tnR.t@�ttt4SI6)Ncek:ttdd;a@nHis[t:44lsd{`�L S?NI.drFLiLC+!S�t3h[ S`±d1A2 srb�'k Rsht3PTr1. TllEku}Sitssti'kdl¢j3MAei�itVttAJ:P! : :�tit[)<Oti :�> T€lifitl0 111P:£:,
�d®a tf�siixLfi;ra!i[�f.xg�st^trts@itx4ilhair>�t03serztCism7tas#stitei[gt n>r�r6•r.��s�ar.ististxtslGSIL I�,�tat�t'�933a,Hu*d[tdeaf(.IH; P�tq@�ssi�d 30Wxi&Ides z:dstkssssiusdie�3mdr+g fuze;tt`"Iler�aaSNe��di6tLsrtespasdiliti : �
.^eEu dnd ssdmtaf lu stsks uiwlittomb I-Diid k�LtC r,,u#¢>�fists�aa dc�dsm°aop #dzcs 5datzuifm;tBsQ@sibsfvi5+iffmtiV4vtts!lttaiitdtar{nm pa€�e: l@t, dr.`,a N'oipaL-;ps to>!eirt4"ait tatte,�.Y;'int�ss �a fz�[erzatmiksa#��r,�ass .
�.:4451.S[JucieBlvd.
{uses ardW4 tr agetdviatt i m3kd, trc an d i6t stiC ytk ntN d3 t dx7 @L a ai st LCs ex Es; L�ti�p116g, t((tialk !#eat uio xis P4l
e_ ..Tr__e.rn - r_..:. r _..L_._;:. L ... It$jttfaCEL 3444b::
._... .. J....,.�_.. w........,s t .4r.._-..� -.L IE� 1T........ t-«a....T T:...L.:1r1 9C
JULY 17, 2017 1 TRUSSED VALLEY SET DETAIL I STDTL06
rrrrr�
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD,
FORT PIERCE, FL 34946
772409-1010
VALLEY TRUSS
(TYPICAL)
i
GABLE END, COMMON
TRUSS, OR GIRDER
TRUSS
GENERAL SPECIFICATIONS:
1. NAIL SIZE = 3" X 0.131" = 10d
2. WOOD SCREW = 3"WS3 USP OR EQUIVALENT.
3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE PER DETAIL
"A•
4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN
DRAWINGS.
5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT
TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING.
6. NAILING DONE PER NDS - 01.
7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
BASE TRUSSES
GABLE END, COMMON
TRUSS, OR GIRDER
P F12 VALLEY TRUSS TRUSS
(TYPICAL)
SEE DETAIL "A"
BELOW (TYP.)
SECURE VALLEY TRUSS
W/ ONE ROW OF 10d WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
NAILS 6" O.C. WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
ATTACH 2X4 CONTINUOUS #2 MAX TOP CHORD TOTAL LOAD = 50 PSF
SYP TO THE ROOF W/TWO USP MAX SPACING = 24" O.C. (BASE AND VALLEY)
WS3 (1/4" X 3") WOOD SCREWS MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
INTO EACH BASE TRUSS.
I
n
DETAIL A
(NO SHEATHING) N.T.S.
arst ci} UJ asrie a rt6xrcti i � }T�sii iry ;.. a sk l•yg3Pee kan�u+�aaa y s as g s wyJs} s +l asslJat t srr }e}a64 # �s l.a�r€.t r dk a rai;#dmJ wtstnte�. Anthony T twlb :ff3;.?.E;
nda�t ei3iiziizst Jt m}3ef i 3l e.)t�s.§'m�tai!9ra tMGrPr':m9risefymcttzWilte;'+.rm:b^w+;tausl'4tfC;;rtc iK�hk amital&rptia vQPL.P.4ie}xc3�`aifie it�.Jrle,�}sl#aassdJ ttin, acl�irgtraG:+asu<y<?u�i.ttatwAlreiegsglldxe seervamiafy ai r�063,
kJ 6+i ; eas R+tratei.:k ups siSrfist SGf 7rvkiL:IttttKattgideli�s'4ka..u,'3ro7(.agaar�id?.n''xireliMtl.SipWP.F.€�iMrad:EfA ver ttt�3e4t g!nkt':laxx 2I'9t3aJnnt=ssgJtl<et 3tsa.�4 ,¢fray �rassEst y=rc,ScKs skc7t.0y'aen TrJis ¢euteixer;s sss 4451St fuee 61v¢:::
fClFN.a Aki a]J iriaa :i£kt�'4viln xt%1§�i�a}ifhk IJii�rtA ai}S �RSS .1]6rL6,3Rn!'.� TS"SE N^ J�.b^.r1�.G: RteSBi}'i l�aA'f�.'AGi7 t1f}}A�his i7 t$�dril"f'�'.1=i aTJ3i aatf l};�i. F -IT1--46:
QOYi�:r-2S�dbiOG��lL55!9:,iA1k66�,T�jOEi�h IiL�'.���tab`tl.if:l1&1"i�➢:tlfl3Yk111A dkfdirb�JDkibllBd W1i�i74i i"3JY5111gI�dtWt31<.f09{IC�t �,6if T7554CXc �AikkAYT..jCRt-0tttri.L' ..
i
JULY 17, 2017 %JI— 1 Lit-1 r%I[—
(HIGH WIND VELOCITY)
STDTL07
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
ATTA(
WIND DESIGN PER ASCE 7-98, ASCE 7-
WIND DESIGN PER ASCE 7-10: 170 MPI
MAX MEAN ROOF HEIGHT = 30 FEET
CATERGORY II BUILDING
EXPOSURE B OR C
WIND DURATION OF LOAD INCREASE:
MAX TOP CHORD TOTAL LOAD = 50 PS
MAX SPACING = 24" O.C. (BASE AND V)
SUPPORTING TRUSSES DIRECTLY UNDER VALLEY TRUSSES MUST BE
DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' -10" ON AFFECTED
TOP CHORDS.
NOTES:
1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES.
2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER.
FOR BEVELED BOTTOM
CHORD, CLIP MAY BE APPLIED
TO EITHER FACE.
I
CLIP MAY BE APPLIED
TO THIS FACE UP TO A
NON -BEVELED MAXIMUM 6/12 PITCH
BOTTOM CHORD
NON -BEVELED
BOTTOM CHORD
CLIP MUST BE APPLIED TO
THIS FACE WHEN PITCH
EXCEEDS 6/12 (MAXIMUM
12/12 PITCH)
0 0
000
g>ru111pilau±+ 4hahuf e'.S-1Vol tit[t 6r:isdrdtsga7��aae!�mt:rit�rsa�sTeosa&she&a mR;TiD;czkmelanu [,AO�st;itLRtbaH;x4kat6ske �.pn'essoha�tlxsiaulae
slit[ tims^H plans>ieU (xairi G>neTp akrd5; L tTtesi h 3e 0a a e, t t +)r+al'.indaxwsr dM sadm m. iD(!rytisrs[S m uttyme e0G je�rxwmd rv�nurngt �nit9it, lvRedek-ey clna svry'rAxt GksA! reth Ttt� s2,; mtrl iN:. ixdeu�itiu�ra:,lydsg rnia
ss6is; el atras liter/a fuq<s ttis nslaas3d�drtt'!wnB, tE[ ae'tastsn:ek�tmeEst i+tlE.�Des~tH ek+:seselat�!IK,t�iti elthzfa;ali;il�s}HEt xzdls"I Ito#Neeae#kt T9 e..fmr'altaasfYe3 fnis: ixidip k»e:�-nrexte:�.wll�nacSiteaq sh4'f5e ctn
x dilEn[£eaghtaed ivxtteta [.7ts;ts idaxto ae(65ud!St jmnns id p dtlw Ott€ Is:ilq c0q;k w^w;mat italpdilot it Ttl and sm wetcffimtwleesail=lmtt r1i; lenses of nspemR:WV4""s ifOtI ssDesty.t,Sms bm 6.PnersidIms Oma
xaecs,isetsrl tid0tddsReed iaxsAt
;ncxli[edprxn kslrt4. 71n irvg2epi}cirEassNi➢4lsiet�Jf'�(Ge.Aralaler_e�tijnlr<o1 e7 TstlaC. pill a�,'blreI,es�a,ate as idirrfmtP{F.
Anliony T. Totn66
80083
4451 St .Lucie Blvd.
P-t 0;.a a. Gt 2d()Af.
FEBRUARY 17, 2017 I STANDARD GABLE END DETAIL I STDTL08
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD,
FORT PIERCE, FL 34946
772-409-1010
* DIAGONAL BRACING
REFER TO SECTION A -A
TYPICAL 2X4 L-BRACE
NAILED TO 2X4 VERTICALS
W/lOd NAILS, 6' O.C.
V ER1
STUD
SECTION B-B
i
TRUSS GEOMETRY AND CONDITIONS
SHOWN ARE FOR ILLUSTRATION ONLY.
DIAGONAL BRACE 4' - 0' O.C. MAX.
SEE INDIVIDUAL ENGINEERING DRAWINGS
FOR TRUSS DESIGN CRITERIA.
12' 1 PROVIDE 2X4 BLOCKING BETWEEN
Q VARIES TO COMMON TRUSS THE'FIRST,TWO TRUSSES AS NOTED.
TOENAIL BLOCKING TD TRUSSES
WITH (2) - 10d NAILS AT EACH END.
ATTACH DIAGONAL BRACE TO
BLOCKING WITH (5) - 10d NAILS
VERTICAL
2X6 SP OR SPF
STUDPBRACE
#2 DIAGONAL
BRACE
(4) - 16d
NAILS16d
NAILS
SPACED 6' O.C.
(2) lOd NAILS
INTO 2X62X6
SP OR
SPF #2
2X4 SP OR
SPF #2L
HORIZONTAL
NAILED TO
RTICALS
SECTION A -A
W/(4) - 10d NAILS
** L - BRACING REFER
TO SECTION B-13
3X4 =
24' MAX.�F�
NOTE:
1. MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS.
2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO
BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT.
3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG.
ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF
SYSTEM.
4. 'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, .SPF OR SP #3 OR
BETTER WITH ONE ROW OF 10d NAILS SPACED 6' O.C.
5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM
AT4'-0' O.C.
G. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN
WITH 16d NAILS SPACED G' D.C. HORIZONTAL BRACE TO BE LOCATED AT
THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE
STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A)
7. GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240.
(4) 8d NAILS MINIMUM,
PLYWOOD SHEATHING TO
2X4 STD SPF BLOCK
12' MAX.
B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL I GABLES. DIAG. BRACE
_9. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS
TRUSSES. IF NEEDED
10. 10d AND 16d NAILS ARE 0131'X3.0' AND 0131'X3.5' COMMON WIRE NAILS
RESPECTIVELY.
11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 05-01-12
BY SPIB/ALSC.
MINIMUM STUD
SIZE SPECIES
AND GRADE
STUD
SPACING
WITHOUT
BRACE
2X4
L - BRACE
DIAGONAL
BRACE
(2) DIAGONAL
BRACES AT
1/3 POINTS
MAXIMUM STUD LENGTH
2X4 SP #31 STUD
12" O.C.
3-8-10
5-6-11
6-6-11
11-1-13
2X4 SP #31 STUD
16" O.C.
3-3-10
4-9-12
6-6-11
9-10-15
2X4 SP 931 STUD
24" O.C.
2-8-6
3-11-3
54-12
8-1-2
2X4 SP #2
12" O.C.
3-10-15
5-6-11
6.6-11
11-8-14
2X4 SP #2
16' O.C.
3-6-11
4-9-12
6-6-11
10-8-0
2X4 SP #2
24" O.C.
3-14
3-11-3
6-2-9
9-3-13
DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE
EDGE. DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO
BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGDNAL BRACE
WITH 10d NAILS 6. O.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER
BOX OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2.
ROOF
SHEATHING
TRUSSES @ 24' O.C.
2X6 DIAGONAL BRACE
SPACED 413' O.C. ATTACHED
TO VERTICAL WITH (4) -
\ 16d NAILS, AND ATTACHED
TO BLOCKING WITH (5) -
10d NAILS.
HORIZONTAL BRACE
(SEE SECTION A -A)
END WALL
MAX MEAN ROOF HEIGHT = 30 FEET
EXPOSURE B OR C
ASCE 7-10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING.
DURATION OF LOAD INCREASE :1.60 CONNECTION OF BRACING IS BASED ON MWFRS.
FEBRUARY 17, 2017
LATERAL BRACING RECOMMENDATIONS STDTL10
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS,
2X6 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY 8 TO 10 FEET
ALONG A FLOOR TRUSS.
NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE
TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY
OF THE METHODS ILLUSTRATED BELOW.
NOTE 2: STRDNG13ACK BRACING ALSO SATISFIES THE LATERAL. BRACING REQUIREMENTS FOR THE
BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS
FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY
CONNECTED, BY OTHERS, AT THE ENDS.
USE METAL FRAMING
ANCHOR TO ATTACH
TO TOP CHORD
BLOCKING BEHIND THE VERTICAL
WEB IS RECOMMENDED WHILE
NAILING THE STRONGBACK,
USE METAL FRAMING
ANCHOR TO ATTACH
TO BOTTOM CHORD
TRUSS
�r
INSERT WOOD SCREW THROUGH
OUTSIDE FACE,OF CHORD INTO
EDGE OF STRONGBACK (DO NOT
ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS)
WEB WITH (3) - 10d SCAB WITH (3) - 10d
NAILS (0.131' X 3') NAILS (0131' X 3'). r ATTACH TO VERTICAL
WEB WITH (NAILS (0 313)X 3')
ATTACH TO VERTICAL
WEB WITH (3) - 10d
NAILS (0131' X 3')
2X6
STRONGBACK
4' -
(TYPICAL
ATTACH 2X4 VERTICAL
TO FACE OF TRUSS.
FASTEN TO TOP AND
BOTTOM CHORD WITH
(2) - 10d NAILS (0.131'
X 3') IN EACH CHORD
ATTACH TO VERTICAL
SCAB WITH (3) - 10d
NAILS (0.131' X 3')
0' WALL
SPLICE) (BY OTHERS)
ATTACH TO CHORD
WITH (2) #12 X 3'
WOOD SCREWS
(0.216. OIA.)
INSERT SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (DO NOT
USE DRYWALL TYPE SCREWS)
THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO -AN ADEQUATE SUPPORT,
DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB
CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0.131' X 3')
EQUALLY SPACED.
ALTERNATE METHOD OF SPLICING:
OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) -
10d NAILS (0.131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY
WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL).
BLOCKING
(BY OTHERS)
FEBRUARY 17, 2017
y.
LATERAL TOE -NAIL DETAIL
I
STDTL11
X.
I
-'
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45" WITH THE MEMBER
AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN
THROUGH ANDIEXIT AT THE BACK CORNER OF THE MEMBER END AS
SHOWN).
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL
BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
SPECIES FOR MEMBERS OF DIFFERENT SPECIES.
FORT PIERCE, FL 34946
772409-1010
TOE -NAIL SINGLE SHEAR VALUES I
PER NOS 2001 (LB/NAIL)
DIA
SP
OF
I HF
SPF
I SPF-S
.131
88.0
80.6
69.9
68.4
59.7
.135
93.5
85.6
74.2
72.6
63.4
J
in
.162
108.8
99.6
86.4
84.5
73.8
ri
.128 74.2 67.9 1 58.9 57.6 1 50.3
Z 131 75.9 69.5 60.3 59.0 51.1
o
,n .148 81.4 74.5 64.6 63.2 52.5
N
M
THIS DETAIL IS ONLY APPLICABLE TO
THE THREE END DETAILS SHOWN BELOW.
VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY.
SIDE VIEW
(2X3) 2 NAILS
NEAR SIDE
NEAR SIDE
VALUES SHOWN ARE CAPACITY PER TOE -NAIL. SIDE VIEW
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIIED. (2X4) 3 NAILS
EXAMPLE: NEAR SIDE
(3) - 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES BOTTOM CHORD
NEAR SIDE
FOR LOAD DURATION INCREASE OF 1.15:
3 (NAILS) X 84.5 (LB/NAIL) X 1.15 (DOL) = 291.5 LB MAXIMUM CAPACITY NEAR SIDE
I
I
ANGLE MAY
VARY FROM
30" TO 60"
45.00'
ANGLE MAY
VARY FROM
30" TO 60°
45.00'
SIDE VIEW
(2X3) 2 NAILS
NEAR SIDE
NEAR SIDE
NEAR SIDE
NEAR SIDE
ANGLE MAY
VARY FROM
30' TO 60°
45.00'
FEBRUARY 17, 2017 I UPLIFT TOE -NAIL DETAIL I STDTL12
f
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772— 09-1010
THIS DETAIL SHALL BE USED FOR A CONNECTION
RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER
IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS.
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30' WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE
MEMBER END AS SHOWN.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION.
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
TOE -NAIL WITHDRAWAL VALUES
PER NOS 2005 (LB/NAIL)
DIA.
SP
OF
HF
SPF
SPF-S
L7
.131
59
46
32
30
20
Z
O
J
4
.135
60
48
33
30
20
•
('7
.162
72
58
39
37
25
J
2
O
.128
54
42
28
27
19
f—
z
Z
JO
.131
55
43
29
28
19
W
.148
62
48
34
31
21
J
J_
N
Q
�
Z
120
51
39
27
26
17
0
Z
.128
49
38
26
25
17
O
.131
51
39
27
26
17
J
0
.148
57
44
31
28
20
EXAMPLE:
(3) - 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES TOP PLATE
FOR WIND DOL OF 1.33:
3 (NAILS) X 37 (LB/NAIL) X 1.33 (OOL FOR WIND) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
FOR WIND DOL OF 1.60:
3 (NAILS) X 37 (LB/NAIL) X 1.60 (DOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LBS (177 LBS) BUILDING
DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION.
*** USE (3) TOE -NAILS ON 2X4 BEARING WALL
*** USE (4) TOE -NAILS ON 2X6 BEARING WALL
NEAR SIDE
FAR S:
)E
TOP PLATE
OF WALL
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
IL
NAIL
NAIL
SIDE VIEW
END VIEW
FEBRUARY 5, 2016
M
A-1 ROOF RUSSES
4451 ST. CUTCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
1.5 x 4
TYP 2x2 NAILER ATTACHMENT I STDTLI3
NAILER ATTACHMENT
ENERAL SPECIFICATIONS
MAX LOAD': 55 psf Roof Load, 170 mph, ASCE
7-10, 29'-0" Mean Height, Exp. B, C or D.
Q \Ao
`� 2x4 SP No. 2 (Min)
o°
o°
o°
1.5 x 4
2x2 SP No. 3
April 11, 2016 TYPICAL ALTERNATE BRACING DETAIL
FO EXTERIOR FLAT GIRDER TRUSS
STDTLI4
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-40971010
(4) 12d
TRUSS 2411 O.C.
UPLIFT CONNECTION
(SEE ROOF TRUSS)
EXTERIOR FLAT
GIRDER
:r
12
VARIES
(4) 12d
MAX 30" (2'-611)
2x6 #2 SP (Both Faces)
2411 o.c.`
SIMPSON H5
w-.j,mvm Rwas#31 9 4.'1"; IM 1wWmHq1,fi st591.r19t tca:d'i8A 1riAbt"GN'1 3kfICA ".afi[:"b r ilt :ipl xh d a€-aht Po ti..'ittg+xr^nelTi,; lode s� a w#ki,F eAewe iacetbe a Upixx aMnT `vAm�aal4: aa�{
a rxca mr.,te+<akr°kn,akrm a:bu.t5t. taal is ot>3pv=ra t":r sa �7 a r �ruur�tue n..p�:tabtnias i:s:ate saa94*1. roasau�+aarsmy�t &Nca kai�ut:••tuTria. Jaaaa<i� rwtt,t +�, u ,.,c u, Anthony T. Tambo lIT<g'.E.
anb.se s?7vit,tiitw mf.�'�ap is^a t+iaaa?�'�t!si wt9rnt,'1e 4'o ds i dA ea'n 3Sib.e gf pe. StwauatN lGf,Ri,tM rK>w3fe WSFksal.atk uAn aN.tbi, Txspp:or skeiAP.�i u;.f,»rd t �EleJ as9. pk�fia;, % ye,btklPfinsa4i+xd.,i skalet iu tnaabiL;ik �, 800S3
' '�!i sTw�pnWW�mw. taus ut �.lae7"apaNa. vm-waf aatg«lf�aaf sa �.dapCs$xw•n.d �tki'a!ax+ "flit sHhptddQJispla�[laarta?et Rt kn gtarai k°1 a tD, l;tt'�.as+`�s zntia '1,b°sd�3 }�ndtsximtaa,tg:. trwafi, 2rp+nrsutrnt A«,aar. re �fn 4457.R. Wdt BNd,
krixHr&FAmikta(xaritepraiymaxt. apkfa?I pf4t xari tAi Teeitd ,gsfs xsna0i bx43irq.as }ia<,aL a *t:asEeyiaett dary 9aiimt. 131 cgibirs€ma. eea. iekrx3 a"PI f. For, Pluce, FL 34946
• tapgightOva A-1 AsalLussses•AnAsag 1,1040fl4P1 Sapsadatt=.nn sfibisds;nmit1,i,,Py thim,btpmbi5ihdrivfham the rrfiuet.pem,'mroa has: Aa RontTtum,- Aptkoy T. Tomb uLF.I:
STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND STDTL15
FEBRUARY 17, 2017 DAMAGED OR -MISSING CHORD SPLICE PLATES
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
TOTAL NUMBER
OF NAILS EACH
SIDE OF BREAK *
X
(INCHES)
I
MAXIMUM FORCE (LBS) 15% LOAD DURATION
SP
OF
SPF
HF-
2X4
2X6
2X4
2X6
2X4
2X6
2X4
2X6
2X4
2X6
20
30
124"
1706
2559
1561
2342
1320
1980
1352
2028
26
39
30""
2194
3291
2007
3011
1697
2546
1738
2608
32
48
136"
2681
4022
2454
3681
2074
3111
2125
3187
38
57
42"
3169
4754
2900
4350
2451
3677
2511
3767
44
66
Q.
3657
5485
3346
5019
2829
4243
2898
4347
• DIVIDE EQUALLY FRONT ANDiBACK
ATTACH 2X_ SCAB OF THE, SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF
THE TRUSS ( CENTER ION BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE
ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (131' DIA. X 3').
STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN
THE MAIN MEMBER. USE A MIN. 3' MEMBER ENO DISTANCE.
THE LENGTH OF THE BREAK (C), SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS)
THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X +
•10d NAILS NEAR SIDE
+ 10d NAILS FAR SIDE
TRUSS CONFIGURATION
AND BREAK LOCATIONS
FOR ILLUSTRATIONS ONLY
THE LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL TO
THE REQUIRED X I DIMENSION FROM ANY PERIMETER BREAK OR HEEL JOINT
AND A MINIMUM OF G' FROM ANY INTERIOR JOINT (SEE SKETCH ABOVE).
DO NOT USE REPAIR FOR JOINT SPLICES
NOTES:
1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR
DOES NOT IMPLY THAT THE REMAINING PORTION OF THE iTRUSS IS UNDAMAGED. THE ENTIRE
TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN
THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF
SUPPORTING THE LOADS INDICATED. 1
2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR
AND HELD IN PLACE DURING APPLICATION OF REPAIR.
3. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID
UNUSUAL SPLITTING OF THE WOOD.
4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID
LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
5. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSESIIN THE 2X_ ORIENTATION ONLY.
6. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS.
FEBRUARY 17, 2017 1 SCAB APPLIED OVERHANGS I STDTL16
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
TRUSS CRITERIA: ,
LOADING: 40-10-0-10
DURATION FACTOR: 115
SPACING: 24' O.C.
TOP CHORD: 2X4 OR 2XG
PITCH: 4/12 - 12/12
HEEL HEIGHT:I STANDARD HEEL UP TO 12' ENERGY HEEL
END BEARING CONDITION
NOTES:
1. ATTACH 2X-SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS
WITH TWO ROWS OF lOd COMMON WIRE NAILS (.148' OIA. X 3') SPACED G' O.C.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. WHEN NAILING ,THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO
AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
2X SC
NOTE: TRUSS BUILT'WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED
WHEN OVERHANG HAS BEEN BROKEN OFF.
IMPORTANT
THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24'
O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD
LOADS NOT EXCEEDING150 PSF. -
TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY.
REFER TO INDIVIDUAL TRUSS DESIGN