Loading...
HomeMy WebLinkAboutREVISION 8-23-18JOey OFFICE USE ONLY: DATE FILED: REVISION FEE: SCANNED BY gtLUdgCOt%* PERMIT# RECEIPT# PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772) 462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: r78�.32 ��►��.�t� ��. DETAILED DESCRIPTION OF PROJECT REVISIONS: n CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: PHONE (DAYTIME): STATE: OWNER/BOILDER INFORMATION: NAME: `) . ADDRESS: 2i CITY: 1 D— PHONE (DAYTIME: ST. LUCIE CO CERT. #: ZIP: FAX: kc1blel l t Kf Ap— �*17 z> 3 z 4LI S 62 STATE: t�L ZIP: O?R FAX: ARCHITECT/ENGINEER INFORMATION: NAME: CITY: PHONE LCCC: 9 RREVIS10"N. Revised 06/.61301I®/]7 FILE COPY II V TOOLED EDGE, PrP. 4' IHICK (MIN.) POURED w � CONC. (2§PD PS! MIN.) > W-W:4xW1.4 WMA roo (OR FlBERMESN) � i-- ir (1) p5 BARB CONTINUWS 1._0. F8 THICKENED EDGE SCALE: 310" =1'-0" SCANNED BY St Lucie County �'jI9: D�S10N COUNT C ST' �UCYE F CO B aEV E USj BvoP - E MpVE p0't PERMl (IONISE S Ne OR NO INSP COpY AUG �fl18 ST, lutlb ��ufltV, permitting DRAFTING SFRVICES SOAN TA PE, 1-LC PHONE: (772) 237-7942 0] 7 � � m O O uHI Q a A u w z 0 � zU � o 0 W A w x � w F� Q 0 z 4 H ~ U Z � W � Q o 00 W W H �m� Q 0 Q aua W NFU ra� r0 W PAUL WELCH INC. MECH-ELEC-CIVIL ENG 1984 SW HILTMORE ST. #114 PORT ST LUCIE', FL 34984 PAUL WELCH, REG. No. 29945 P.E. FLA Date: AUG 2 12018 SCALE: 1/4" = 1'-0" JOB No: 517-0639 P1B 8" MASONRY WALL, SEE PLAN #5 REBAR 048" O.C. (MAX.) & AS SHOWN ON PLANS 10" VERIFY W/ - 3/4"X8" WIDE BLOCK RECESS DOOR MANUF. n 4" THICK (MIN.) POURED CONC.ICK (25 OINPSIPOUM NR)D 0 7-V' _CURB FINISHED FLOOR CONC. (2500 .PSI MIN.) w FINAL GRADE FINAL GRADE a �' ` ^T z�74 i.� 12" MIN: EMBEDMENT - - .. -- - - - ---_ ----- _ ----- --- - - - - -- - 6x6-W1.4xW1 4 WWM �: ' -. - 12" MIN. EMBEDMENT BELOW EXISTING GRADE ., ' 3" MIN. (OR FIBERMESH) ��, BELOW EXISTING GRADE' (2) #5 CONTINUOUS REBAR 1'-6" CLEAR COVER 6" (TYP.). THICKENED EDGE 1�-6" (2) #5 CONTINUOUS REBAR 1'_g" MIN. FOOTING WITH (2) #5 MIN. 6X6-W1.4xW1.4 WWM BARS CONTINUOUS DOUBLE WITHIN 3 FT. FROM FOOTING (TYP) (OR FIBERMESH) - F1 EXTERIOR WALL FOOTING �` FOOTING AT OHGD SCALE: 3/8" = 11•01. T _ 3 Y2" POURED CONC.� PORCHSLAB 12" MIN. EMBEDMENT - BELOW EXISTING GRADE. 7 (2) #5 CONTINUOUS REBAR MASONRY WALL, SEE PLAN 5 REBAR 048" O.C. (MAX.) & AS SHOWN ON PLANS Y4"X8" WIDE BLOCK. RECESS n s 4" THICK (MIN.) POURED CONC. (2500 PSI MIN.) j2'" DIA.x10" A.B. 024" O.C, F.F. MAX. W/7" MIN. EMBED. 2 (MIN.) P.T. SOLE PLATE /, F. F. 3" MIN. CLEAR COVER 1�_6,. 6„ MIN. 6X6-W1.4xW1.4 WWM DOUBLE WITHIN 3 FT. �I FROM FOOTING (TYP) (OR FIBERMESH) EXTERIOR STEP BEARING 7-5/8" CURB 1 L z �k FINAL GRADE 12" MIN. EMBEDMENT BELOW EXISTING GRADE 7 (2) #5 CONTINUOUS REBAR MIN. SHOWER CURB SCALE: 3/8" = 4" THICK (MIN.) POURED CONC. (2500 PSI MIN.) ,. 8" :t 6X6-W1.4xW1.4 WWM DOUBLE WITHIN 3 FT. FROM FOOTING (TYP) (OR FIBERMESH) SCALE: 3/8" = 1'-0" C.0. 1_� V 2" 2" VTR 2,. � a TUB wC L F6� INTERIOR STEP NON -BEARING SCALE: 3/8" = V-0" 2x4 FRAMED NON -BEARING WALL SEE TYP. DETAIL FOR CONNECTION TO FOUNDATION -3 X" THICK (MIN.) POURED CONC. (2500 PSI MIN.) 6X6-W1.4RW1.4 WWM (OR FIBERMESH) —(1) #5 BARS CONTINUOUS :: 3/8" = V-0" _8" MASONRY WALL, SEE PLAN —#5 REBAR 048" O.C. (MAX.) & AS SHOWN ON PLANS — 4" THICK (MIN.) POURED CONC. (2500 PSI MIN.) ]--I i 3_MJN. AR COVER (TYP.). �-- 6X6-Wl.4xW1.4 WWM DOUBLE WITHIN 3 FT. FROM FOOTING (TYP) (OR FIBERMESH) 4" THICK (MIN.) POURED CONC. (2500 PSI MIN.) 6x6-WI.4xWi.4 WWM=� (OR FIBERMESH) THICKENED .EDGE FOOTING WITH (2) #5 BARS CONTINUOUS 3/8" = A PLUMBING LEGEND AND ABBREVIATIONS - — SANITARY SOIL PIPE (BELOW FLOOR SLAB) DRY VENT LINE BRANCH ABOVE CEILING (RE -VENT) VTR SOIL PIPE VENT THROUGH ROOF WC WATER CLOSET (TOILET) \ NOT LESS THAN 6 INCHES AND CONTINUOUSLY TAPPED WITH HIGH DENSITY LAV: LAVATORY \ POLYETHYLENE ADHESIVE TAPE. SHR SHOWER TUB TUB SINK 3" VTR \ J KS KITCHEN SINK ' LT LAUNDRY TUB WASH 2 \ \ DW DISH WASHER T \3" C.O. CLEANOUT C.O. T.G. CLEANOUT TO GRADE \ \ 4" (MIN.) BUILDING SEWER 3' — — — — TSSEWER SL FT STAITIONY C.O.T.G. J VTR „ 1 \ V 2" 2" 2„ —3SHR 2' VTJ 4" 3., / UUU / 2" VTR \ WG V I` / \ f 3 TUB 21 / 3" SANITARY SOIL/WASTE DRAIN PIPE (EXACT LOCATION �, TO BE FIELD LOCATED) / 4 LAV. S LAV. / WC \ q / LAV. 2" VTR / J � 3„ / / i ' WASTE, DRAIN AND VENT RISER DIAGRAM SCALE:NTS " VTR V 2" / LAV. 2„ WC 2 TUB 2 2„ \ 311 \ AUTO \ VENT 3_ �— — KS -- DW AIR GAP F3 CURB SECTION F4 FOOTING BEAMING SCALE: 3/8" = V-0" CONCRETE FOUNDATION NOTES 1. SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS, SEE PLAN FOR SIZES & STEEL REQUIREMENTS. 2. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3" SUBGRADE PREPERATION NOTES 1. THE AREA WITHIN THE LIMITS OF THE FOUNDATION SHALL HAVE ALL VEGETATION, TOP SOIL AND FOREIGN MATERIAL REMOVED. 2. CLEAN FILL SAND AND OR GRAVEL FILL, FREE OF VEGETATION AND FOREIGN MATERIAL, MUST BE PLACED TO DESIGN SUBGRADE LEVEL AND COMPACTED TO ASSURE UNIFORM SUPPORT OF THE FLOOR SLAB. 3. SUBGRADE COMPACTION SHALL BE ACHIEVED BY MEANS AND METHODS DETERMINED BY THE RESPONSIBLE CONTRACTOR. SOIL DENSITY TESTING BY INDEPENDENT SOILS 2" VTR TESTING FIRM SHALL BE REQUIRED TO INSURE PRESCRIBED SOIL DENSITIES ARE J ACHIEVED. 4. AFTER FOOTING EXCAVATION, AND FORMING, CONTRACTOR SHALL RECOMPACT SUBGRADE SOILS USING SUITABLE VIBRATORY MECHANICAL COMPACTOR. THE UPPER 16 INCHES OF SOILS UNDERLAYING THE WALL FOOTINGS SHOULD HAVE A MINIMUM DENSITY OF 95% OF THE MAXIMUM DRY UNIT DENSITY AS DETERMINED BY / LT MODIFIED PROCTOR METHOD FOR THE EXISTING SOILS. IN -PLACE SOIL DENSITY TESTS SHOULD BE PERFORMED IN ACCORDANCE WITH ASTM D-2922, AT A FREQUENCY DETERMINED BY THE SOIL TECHNICIAN TO VERIFY UNIFORMITY OF THE UNDERLYING SOIL DENSITY, PRIOR TO PLACING CONCRETE. 5. SUBBASE COMPACTION FOR THE FLOOR SLAB FILL MATERIAL SHALL BE UNIFORMLY COMPACTED TO A MINIMUM DENSITY EQUAL TO 95% OF THE MAXIMUM DRY UNIT DENSITY OF THE FILL AS DETERMINED BY MODIFIED PROCTOR METHOD IN C ACCORDANCE WITH ASTM D-1557. 1 6. CONCRETE SLABS ON GRADE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER WITH A MINIMUM THICKNESS OF 6 MILLS, INSTALLED WITH LAPPED JOINTS Lddi=p DRAFTING SERI SOAN SAFFE, LI PHONE: (772) 237- www.,�.e.s"�co..s+a"n. w ti O ti G W � IrA Q a 0 00+ 0 0 A U H1 a a Ga C4 CG ^ 00 m Go m z4d PAUL WELCH r NTECH-ELEC-CIVIL I984 SW BILTMORE t PORT ST LUCIE, FL PAUL WELCH, P.E REG. No. 2994 Date: AUG 2 120 SCALE: AS NO' JOB No: 517-06 P2 CONCRETE SLAB EDGE (VERIFY SIZE— w/HOMEOWNER) n 14'-5" 7'-6" 4r-8r, I UTILITY SLAB —11 GRANT E SILL 25SH EGRESS 23SH TEMP. Is m I Is F8 o I I 18,-0" 2,- 6„ N ■ o DO Mo o BATH 3 ° �I ,n m K w 00 ° x 9'-1" CLG/TILE 3 o _� MEDIA ROOM N 1 to N ■ Es � o o INVERTED VAULTED/TILE G N J= CC) 00 X668B 00N 'mm I i� ■ 0_ N V) 000 W c0 i r) Un 0 r I ■ n HB U� x& OUTDOOR SHOWER GYM 9' V CLG/CARPET _LL-LLL\ ■ L-4CE 35SH E I _L MEDIA ROOM/ BEDROOM #3 VAULTED/TILE TYPIC L INTERIOR (NON -BEARING) PARTITION WALLS OF METAL STUDS @24" O.C. ON 2" P.T. SOLE PLATE W/1/ " GYPSUM BOARD DRYWALL (UNLESS OTHERWISE NOTED) STEAL BEARING: POST Zb JY ■ r c r I FAMILY 11'4' CLG/TILE 4'-3" GRANT E SILL ITL-10 23SH TEMP. 35SH EGRESS L-1010 co L coI(o 1 0 1 Lo BEDROOM #2 1 LL o r_8rr o VAULTED/TILE 10 RETUR oo o � ATH #2 ��6� 1 I o 00 9'-1" CLG/TILE 4 1 _ HU #1 <r O I WARE �� LINEN 010 1 7— SHELVES �� 1668B DO F= 00 a U) W J = 0 I ETU o z cello 40 1 \ �I IHT 28 8 AHU\#2 z 6" WALL 3" VTR O c, .... o N _ LA{�gRY y ASHER 11 ,RY R CC WALL OVEN COOKTOP LLOCATION LLOCA ON , w/VENT THRU ROOF LA�NDI Y N MICROWAVE 9'-11, ��G/TILE ;,1 8'-8 20 FIRE '-0' DRYER CLOSING 2868 VENT 2868 SC UU x \\�\ ISLAND aOd ����T0* — — l0 I[— — —— — — — —� ° N — KITCHEN Ci SPA_E o I I I 11'-1" CLG/TILE i DINING ROOM TRAY CLG./TILE '0- 42" HIGH BAR I I RAISED FLOOR 4" TOP COUNTER I (4i' T&G PLYWOOD SHEATHING OVER 2X4 P.T. SLEEPERS 016° D.C.) T77 6-1 t DOUBLE DOOR NOOK G�✓/��G_ I 11,-1„ CEILING y> 11'4' CLG/TILE 10'-7" 3'-8" l,ti\,\,\ -18 H36 SH ■ 2,-Orr 40'x41' CONCRETE SLAB I J z 2' -6" 3'- " i� �I I � ■ NOTES: � o 40'x41' CONCRETE SLAB (1Y2"Wx3)/4'H DECKO DRAIN) (VERIFY SIZE AND LOCATION WITH L`I I J� w(4' TRRISEAD V) 8"0x1 O'H (CUT TO Fl7 (ra ENDURA-STONE COLUMN TIP.) O.� 2'-1 (LOCATE BY HOMEOWN R) OQC9 TL o -0 3'-1r' 4'-s" 3'-0" FOYER I mw 14'-1" CLG/TILE op 0 cw 1 0W O) J ART NITCH sy � HOMEOWNER PROVIDE FOOTINGS PER SHEET P1B I m LIVING I o J 11'4' CLG/TILE WOOa' RTRSE) EAD G� SCREEN ENCLOSURE BY OTHERS (I (SEPARATE PERMIT) ■ COVERED PORCH o O 'x5' CONC. PAD 0 HOUSE PUMP my FILTER HB F —1 3 CAR GARAGE 9'-4" CLG/CONCRETE 12" DIA. COLUMN BLOCK OVER 20" SQ. IIIN BQ� MASONRY BLOCK BASE REINFORCED W/(2) #5 VERTICAL BARS GROUTED 3 IIIN TI Uo\ SOLID (2 PLACES TYPICAL) mcf) IIIN -,0 N �HN Lace a l J M I I I ■ C) \ / I CD \ / \ / 4 xm HB 8'-0" = I CC 3 o o T Lo T N� N v3'-6'r Ln \\ co /7 I I Lir III 0� III P -6 M L-s M LowIIIN Z �w IIIN w III" ;Of �Of III 16070 OHG 0 8070 OHGD 178 16'-0" 2,-0„ 8'-0 3'- 1'-4" (VERIFY SIZE AND LOCATION WITH HOMEOWNER) rn 9'-1"/CONC. L15'- sc9 z CC) ro/-6or7,-1„5r-Or,14'-4"SLOPE I 12" SQ. MASONRY PASS—THRU COUNTER 1 0 12" DIA. COLUMN BLOCK OVERLEGEND 1% COLUMN BLOCK STUDY 20" SQ. MASONRY BLOCK BASE J w/ (4) #5 (MIN.) 266 SC ° 36" AFF o REINFORCED W/ (2)#5 VERTICAL BARS VERT. BARS GROUTED GRANITE TOP 11'-1" CLG/TILE T AB 16'-0"H x 8" CMU MASONRY WALL ZI SOLID (4 TYPICAL) GROUTED SOLID 8 PLACES TYPICAL RAISED FLOOR 4" = N ( ) i7 N �I HALF BATH 0 - SHEATHING OVERw2X4D P.T. N J r U SLEEPERS 016" O.C.) 21'-4' H x 8' CMU MASONRY WALL a3 0 I 3'—z' 2'-2' 5'-0"WET BAR N - 9 R-13 INSULATION ° INTERIOR 2x4 STUD NON -BEARING PARTITION WALL p I S CUSTOM BUILT-IN BOOKCASE (PER MOM WNER) ■ PRE -CAST CONCRETE LINTEL ■ ■ •• gS/iTFM L-1 DESIGNATION (SEE SHEET-A6) ■ I ��cj' — — — — — — — — — n GJ A V-8" /�----------{ I ___— qRy 8p aG� / I 2 668 1 r 22" x 36", I .0 H1 N SOIL PIPE VENT THROUGH ROOF ` P VTR / IATTC AccESSI ( o 25 SH WINDOW MARK (ALL IMPACT) g2 ♦ / / I I - - - - W.I.C. (SEE MANUFACTURER'S SPECS ' �4�h j / I I N cb ■ L' / 40688E 28686E FOR DETAILS) o V w N ZI Ic \�` // I N I IN 6080 FR DOOR MARK (ALL IMPACT) al co I MASTER BDRM. I I 5'-1" s'- 4'- T I Le I x Q3 II ° 4 (6'-O,W x 8 -O'H SPORTS SHOWER �I IN CD TRAY CLG./TILE U) OPENING) NOMINAL p I S- N 7 F8 CONCRETE SLAB EDGE 40'-0" ,2'- 0 28'-8" I m I I T-1" CLG/TILE I 1n H- v=i = 5068SLD ^I N N z 22'-6.r I I 9'-0" I 14'-1 �" • M m I ■ ■ -------------- W.I.C. ■ y� J----------------� ----- — R2'- Hi 4N Ss L --J IP 2'-8" 3 H31;ISH H36S� HB 5' -11„ -13 12'-0" ILL im 25'-9„ 3'-2" 43'-8" 3'-101, 1'-4" 3'-6" 52'-0" 86'=2" BUILDER'S NOTES 1. GRANITE COUNTERTOPS FOR ALL BATHROOMS, KITCHEN, & WET BAR 2. GRANITE SILL ® ALL WINDOW SILLS 3. BUILT-IN UNITS SIZE AND LOCATIONS PER HOMEOWNER BUILDER 4. WELL CONNECTION 5. SEPTIC CONNECTION 6. WHOLE HOUSE AQUASANA WATER FILTRATION SYSTEM TO BE INSTALLED 7. 8"0 X 10'H (CUT TO FIT) ENDURA-STONE COLUMN IN FOYER (BUILDER LOCATE) 8. CONTRACTOR SHALL PROVIDE LIGHT POLE PER OWNER'S SPECIFICATIONS MIRROR o I d 0 o T (V II of G 9 MASTER BATH VANITY DETAIL (VERIFY DESIGN w/HOMEOWNER) AREA TABULATION LIVING: 4,218 SQ. FT. GARAGE: 1,073 SO. FT. ENTRY PORCH: 150 SQ. FT. COV, PATIO: 418 SQ. FT. T TAL: 5,859 SQ. FT. UNIT 1 — A/C VOLUME: 27,832 CU. FT. UNIT 2 - A/C VOLUME: 18,221 CU. FT. Z CROOF OVIDE SPRAY FOAM INSULATION AT K ALL AREAS ABOVE LIVING SPACE Q 5 BEAM HANGER MAi2K TYPE "SIMPSON" HUC410 WITH (18)-1/4" X 2 3/4" TITEN TO WALL AND (10)-10d NAILS TO BEAM ij� . DRAFTING SERVICES - SOAN SAFE , LLC PHONE: (772) 237-7942 .arowvcc�a.com m rn m � o a h � w � (7 3 zz] A A u W 0 0 0 0 z� A a w w w w f,1 0o co 07 w ro w H Q 0 0 0 m 0 0 0 0 z Qaa1 rW V z Z� N 00 O I A y V M 0�0 A wU O AaW ® O ®l Nf�U I—i 00 a V) PAUL WELCH INC. MECH ELEC CIVIL ENG 1984 SW BILTMORE ST. #114 PORT ST LUCIE, FL 34984 PAUL WELCH, P.E. FLA REG. . 29945 Date: AUG 2 12018 SCALE: 1/4" = 1'-0" JOB No: 517-0639 i Al L 115'— 2'_0„_ 26'-7" lid 16'-2" n. a - F1 ■ P2 ■ ■ ■ ■ — — — ■ ■ _ — ■ ■ TYP. 8" CONCRETE ■ oil I0I___ _ J BLOCK WALL L o — — — — — — — /— — o (SEE SHEET—A5/DETAIL.1) /P2-�� F1 III ■ I N II F CJI P2 I ■ I G ■ BEARING '• \ POST 2 '-8" 19'-10" —III 1 I III I POUR IN PLACE COLUMNS 0 0'-0 TOP OF -SLAB • '� WALL OPN'N/JAMB WHERE III INDICATED (TYP.) ■ III #5 VERT DOWEL REINF. ® III ALL WALL OPN'N/JAMB AND o 0 Ft @ 4'-0" O.C. MAX (TYP.) Pz � I i S-10" x 14' LONG 4" THICK MIN. POURED CONCRETE UTILITY SLAB WITH THICKEN EDGES REINFORCED WITH 6x6—W1.4x1.4 WWM Ft -P2 WATER FEED LOCATION - FOR AQUASANA HOUSE FILTER I � _ 1 I N 4" PVC PIPE SLEEVE BELOW FLOOR SLAB 1 1 FOR COMPRESSOR SUPPLY AND RETURN PIPE 1� , ETUR , AH #1 N I p �1 F6 �1 P2 11 RECESS SLAB 4 ll 1 E R BELOW FINISH FLOOR 17' ' ' 3" 3'-6" 2—6f I I L—_J 66' X 66" X 36" DEEP (2500 PSI) P2 I CONC. PAD FOOTING WITH #5 BARS AT 8" O.C. BOTH WAYS TOP AND BOTTOM —4" (o — I N HB 8'-0' N F1 I ■ I TYPICAL- 8" CONCRETE BLOCK WALL III V-0' P2 I i p REINFORCED W/#5 BARS AS INDICATED ITOP OF SLAB p HB WITH CONTINUOUS TOP OF WALL BOND � � I I IOn/ °o BEAM USING (2) 8" "H" BLOCK w/(1) �A #5 BAR IN EACH GROUTED SOLID \ —6„ 3'-6„ — •• \f F5 III ALIGN W/ROOF TRUSS GIRDER —------ --- P2-- --- — � III== == == == ==— _= ■ I 1/2" EXPANSION JOINT SLOPE 1% e DOWEL ROD REPAIR NOTES IN THE EVENT STET HAS BEEN INADVERTENTLY OMITTED FROM DOWN POUR LOCATIONS, DRILL 6" INTO CONCRETE (NO CLOSER THAN 33/4" FROM EDGES AND 5' FROM ENDS OF CAP WALLS). REMOVE DUST PER MFG'S INSTRUCTIONS AND USE TWO PART EPDXY TO ANCHOR #5 REBAR IN PLACE. USE EITHER HILTI C-100 OR SIMPSON EPDXY —TIE. 4" THICK SLAB WITH THICKEN EDGES WITH FIBERMESH 1 III^III VERIFY SIZE V P2 BOTTOM EDGE a 0 44'-4" BOTTOM EDGE I , (SEE TRUSS LAYOUT PLAN FOR ALIGNMENT) // F4 P2 F4 Pz M ■ ■ CD O I(0 \ 4" THICK SLAB (2500 psi min.) I 2'-10" F4 IN ` REINFORCED w/ 6x6 — W1.4xW1.4 WOVWN WIRE MESH (OR FIBERMESH) ON 6 MIL VAPOR BARRIER OVER I P2 I M F5 _4" h SLOPE CLEAN COMPACTED MI PACTED TERTE TREATED 1 - I P2 2'-6" 3'-0" I PREPARED SUBGRADE P2 I ^ 1/a" /Fr o I i� ■ P2 p�P° Il\ O I RECESS SLAB 4 ■ BELOW FINISH FLOOR EPz 9C'p� \ ■ M m 9! 1 SLOPE 8'-0" 1 /B" /FT N I —4" I Ft I N III P1 I p P2 I 3 —2 -2-2 5 —0 ■ I I N873 I J6'-2Y2" I. / I .. '-8" d ■ I� / �--- / _4' c ■ Ipi 0'-0" TOP OF SLAB FZ $F4. ■ 0 • SLOPE. U F5 / " /FT u I P2 LO TYPICAL 8" CONCRETE BLOCK WALL REINFORCED W/#5 BARS AS INDICATED \ ■ O WITH CONTINUOUS TOP OF WALL BOND ■ ■ c BEAM USING (2) 8" "H" BLOCK w/(1) —4" J ■ #5 BAR IN EACH GROUTED SOLID 0 _ Ft P2 4'-1 8,-2„ 3'-2" 43'-8" 3'-10" 1'-4" 52'-0" 86'-2' POUR IN PLACE COLUMNS WALL OPN'N/JAMB WHERE INDICATED (TYP.) F2 F2 FEr:n _ ij� ' DRAET'ING SERVICE: JOAN JAF E, LLC PHONE: (772) 237-7942 A Q Q U PAUL WELCH INC. MECH-ELEC-CIVIL EI 1984 SW EILTMORE ST. a PORT ST LUCIE, FL 349 PAUL WELCH, P.E. FL. PEG. No. 29945 Datb.UG 2 12018 SCALE: 1/4" = V4 JOB No: 517-0639