Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL'ST[f, am OF J P & Professional Reaulation BCIS Home I Log In I User Registration I Hot Topics I Sul 7., PRN011E.. wirT'GBPROH(ACTDSPR c: Florida Product Approval'�USER:PubiicUser ra RECEIVED ee"35� Product Approval Menu > Product or Application Search > A licition List > Application Detail MAY 11 2018 OFMCE OF THE FL # FL5259-R27 SECRETARY Application Type Revision ST. Lucie County, Permitting Code Version 2017 Application Status Approved ' THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS Comments REQUIRED BY FIELD INSPECTORS THAT Archived MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1378 Ext 24 alender@polyglass.com'�''`��� ST. LUCIE COUNTY BUILDING DIVISION Authorized Signature Ariel Lender REVIEWED COMPLIANCE e alender@polyglass.comREVIEWED KPRMIT. DATE PLANS ANDMUST BE EPT ON JOB Technical Representative Maury Alpert NO INSPECTIONS) WILL BE MADE Address/Phone/Email 1111 W. Newport Cente IifeOR Deerfield Beach, FL 33442 (912) 429-8610 MAlpert@polyglass.com Quality Assurance Representative Ariel Lender Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1230 ALender@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer U Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/05/2018 Validated By John W. Knezevich, PE 9 Validation Checklist - Hardcopy Received Certificate of Independence FL5259 R27 COI 2017 01 COI Nieminen.odf Referenced Standard and Year (of Standar) Standard Year ASTM D 1970 2015 f �" CONCEALED FAST EENE.RS OR ATTACHMc 1 S ASTM D226 2009 ARE THE RESPONSIBILITY OF THE ASTM D6164 2011 CONTRACTOR OR RECORD ASTM D6222 2011 FM 4474 2011 FILE COPY FRSA/TRI April 2012 2012 TAS 103 1995 ia TAS 110 �' z 2000 UL 1897 �, 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/14/2017 Date Validated 09/15/2017 Date Pending FBC Approval 09/18/2017 Date Approved, 12/12/2017 Date Revised 01/24/2018 Summary of Products FL # Model, Number or Name Description 5259.1 Polyglass Roof Roofing underlayments - Underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL5259 R27 II 2017 09 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- R27.pdff Approved for use outside HVHZ: Yes Impact,Resistant: WA Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design, pressure in this Evaluation Reports application relates to one particular FL5259 R27 AE 2017 09 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- R27, pdf underlayment system (over concrete deck) for use under foam -on tile systems (where the Created by Independent Third Party: Yes underlayment forms part of the load -path). Refer to ER Section 5.6.4 for other systems, other deck types and associated maximum design pressures. 2.) Refer to ER Section 5 for other limits of use. Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AAIEEO employer. gnydgc ht 2007-2013 State of Florida.:: Privagy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ®® WE eCheck Credit Card Safe QoTRIN' ITY I ERD EVALUATION REPORT Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 98408 (570) 384-1230 EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 (203) 262-9245 Evaluation Report P12060.02.09-1123 FL5259-R27 Date of Issuance: 02/24/2009 Revision 23: 09/14/2017 SCOPE: This Evaluation Report is issued under Rule 61GM-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance witi the 66 Edition (2017) Florida Building Code sections noted herein. LABELING: Labeling shall be in accordance with the requirer CONTINUED COMPLIANCE: This Evaluation Report is valid. un Quality Assurance documentation changes, or provisions o Evaluation Report by the named client constitutes agreemi referenced Quality Assurance documentation changes. Ti relative to updated Code requirements with each Code Cyc ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 CERTIFICATION OF INDEPENDENCE: 1. Trinity[ERD does not have, nor does it intend to acquir distributing products it evaluates. 2. Trinity I ERD is not owned, operated or controlled by any 3. Robert Nieminen, P.E. does not have nor will acquire, a fi which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a I product. 5. This is a building code evaluation. Neither Trinity I ERD project on which this Evaluation Report, or previous vers specifically for that purpose. ents the Accredited Quality Assurance Agency noted herein. it such time as the named product(s) changes, the referenced the Code that relate to the product change. Acceptance of this nt to notify Robert Nieminen, P.E. if the product changes or the nityJERD requires a complete review of this Evaluation Report The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 09/14/2017. This does not serve as an electronically signed document. or will it acquire, a financial interest in any company manufacturing or tmpany manufacturing or distributing products it evaluates. incial interest in any company manufacturing or distributing products for ancial interest in any other entity involved in the approval process of the r Robert Nieminen, P.E. are, in any way, the Designer of Record for any ns thereof, is/was used for permitting or design guidance unless retained �I TRINITY JERD gn!Lty Examination Reference Date ERD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD (TST 6049) Physical Properties P40390.08.12-2 08/07/2012 ERD (TST 6049) Physical Properties C41420.09.12-3 09/11/2012 ERD (TST 6049) Wind Uplift P39680.03.13 03/04/2013 ERD (TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD (TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 ERD (TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 ERD (TST 6049) Wind Uplift P41630.08.13 08/06/2013 ERD (TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 E RD (TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 ERD (TST 6049) Physical Properties P45270.05.14 05/12/2014 ERD (TST 6049) Physical Properties 6020.07.14-1 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-2 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-3 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-4 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-5 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-6 09/08/2014 ERD (TST 6049) Physical Properties P46520.10.14. 10/03/2014 ERD (TST 6049) Physical Properties P44360.10.14 10/07/2014 ERD (TST 6049) Physical Properties P43290.10.14 10/17/2014 ERD (TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015 ERD (TST 6049) Physical Properties P40390.04.15 04/03/2015 ERD (TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015 ERD (TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016 ERD (TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016 ERD (TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 ERD (TST 6049) Physical Properties PLYG-SC13040.12.16 12/27/2016 ERD (TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017 ERD (TST 6049) Physical Properties PLYG-SC12115.08.17 08/08/2017 ICC-ES (EVL 2396) IBC Compliance ESR-1697 11/01/2014 Miami -Dade (CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015 Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 10/05/2018 4. PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlayments: 4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. 4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet. 4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet. 4.2 ' Self -Adhering Underlayments: 4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R23 Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27 Polyglass Roof Underlayments; (570) 384-1730 Revision 23: 09/14/2017 Page 3 of 14 (-)o -I I RINITi I ERD 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Shingles Nail -On Tile Foam -On Tile Metal Wood Shakes & Shingles Slate Elastobase Yes Yes (Base Sheet in2-plysy m) Yes (Base Sheet in 2-ply system) Yes Yes Yes Elastobase P Yes Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) Yes Yes Yes Polyglass G2 Base No Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) No No No Polyglass APP Base No Yes (Base Sheet In 2-ply system) I Yes (Base Sheet in 2-ply system) No No No Polystick I R-Xe Yes No No No Yes Yes PolystickTU P Yes Yes Yes (See 5.5.1) No Yes Yes PolystickTU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes PolystickTU Max No Yes Yes (See 5.5.1) Yes No No Polystick Dual Pro Yes No No Yes Yes 'Yes Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick MU-X Yes No No Yes Yes Yes Elastoflex 56 G Yes Yes Yes (See 5.5.1) No Yes Yes Elastoflex S6 G FR Yes Yes I No No Yes Yes Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G Yes Yes Yes (See 5.5-1) No Yes Yes Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Yes Yes Yes (See 5.5.1) No Yes Yes 5.5.1 "Foam -On Tile" is limited to use of the following Ppproved tile adhesives / underlayment combinations. TABLE lA: ALLOWABLE TILEADHESIVE/ UNDERLAYMENT COMBINATIONS) Adhesive Florida Product Underlayments Approval DAP Foam Touch 'n Seal StormBond Roof FL14506 PolystickTU Plus, Polystick TU Max Tile Adhesive Dow TileBond'" FL22525 Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro PolystickTU P, PolystickTU Plus, PolystickTU Max, Polystick Tile Pro, ICP Adhesives Polyset® AH-160 FL6332 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) PolystickTU P, PolystickTU Plus, PolystickTU Max, Polystick Tile Pro, ICP Adhesives Polyset® RTA-1 FL6276 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) Polyglass Polyl-ok Roof Tile Adhesive FL17855 PolystickTU Plus or PolystickTU Max 'Refer to Tile Manufacturer's or Adhesive Manufacturers Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R23 Certificate of Authorization #9503 6'H EDITION (2017) F I C NON-HVHZ EVALUATION FL5259-RZ7 Polyglass Roof Undgrlayments, (570) 384-1230 Revision 23: 09/14/2017 Page 5 of 14 A rTMN1-ryJERD 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete. 5.6.2 Bond -to -Insulation: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board. Elastoflex G TU, Elastoflex 56 G or Elastoflex S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. 5.6.3 Bond to Mechanically Attached Base Laver: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase.P or Mule -Hide Nail Base. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in' hot asphalt to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch -applied to: ➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R23 Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ7 Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017 Page 6 of 14 5.9 F)o I \,I 1 RINITY I ERD When loading roof tiles on the underlayment i direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exce�ded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIREcr-DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Elastoflex G TU Flat 10-tile stack 7:12 Lugged 8-tile stack (6 over 2) 6:12 Elastoflex S6, G or S6 G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polystick MTS Flat or Lugged Prohibited without battens N/A Polystick Tile Pro Flat or Lugged 6-tile stack (4 over 2) 7:12 Polystick TU Max Flat 6-tile stack (4 over 2) or 10-tile stack 7:12 Lugged 6-tile stack (4 over 2) 7:12 Lugged 10-tile stack 6:12 Polystick TU P Flat 6-tile stack (4 over 2) 6:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick TU Plus Flat or Lugged 6-tile stack (4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 Polyflex G or G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack (4 over 2) 4:12 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installe ' in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 h rein and the specifics noted below. 6.2 Re fasten any loose decking panels, and check fo protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prim the substrate (if applicable). 6.3 Elastobase, Elastobase P or Mule -Hide Nail Base 6.3.1 Non -Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase, Elastobase P or Mule -Hide Nail Bas may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APPCap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. 6.3.2 Tile Applications: Elastobase, Elastobase P or Mule -Hide Nail Base Ply System" from FRSA/TRI April 2012 (04-12). 1 FRSA/TRI April 2012 (04-12) Installation Manual limited to use as a mechanically attached base sheet in the 'Two •ence is made to Table 1 and Section 5.6.4 herein, coupled with Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1123 Certificate of Authorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1127 Polyglass Roof Underpayments; (570) 384-2230 Revision 23: 09/14/2017 Page 11 of 14 As rTFUNITY I ERD 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.4.2 Direct -to -Deck with Mechanically Fastened Roof Covers: All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule - Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to coverthe area being back -nailed. All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). View of Ovelap Seam of Dual Pro and Tile Pro All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 Ib roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 Tile Aoolications (not allowed for Polystick Dual Pro, IR-Xe or Polystick M": Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1. For adhesive -set the applications, refer to Section 5.6.4 herein. For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. 6.4.4 Two (2) Ply Underlayment Systems: Polystick MTS followed by Polystick MTS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R23 Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1127 Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017 Page 12 of 14 r, FLORIOA,OUPARttraNT OF Business & Professional Regulation Florida Product Approval 1 P .USER: Public User C a'rdTs�sm�� Product Approval Menu > Product or Application Search > FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who der Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By �.L 'I "`�t� to • � ;�- DBFRHow- A r baFR DBPRDjVISIONS. , C0WAGTD8PR > Application Detail FL17022-R7 Revision 2017 Approved 08/18/2017v. date reapply 08/21/17 u Extreme Metal Fabricators, LLC 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 flvalidation @ya hoo. co m Richard McKuhen fivalidation@yahoo.com Richard McKuhen 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 rchard@emfab.net Roofing Metal Roofing RECEIVED MAY 11 Z018 ST. I.ucig County, Permitting Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer D Evaluation Report - Hardcopy Received the LOCKE BOWDEN PE-49704 Keystone Certifications, Inc. 04/22/2024 Zachary R. Priest, P.E. O Validation Checklist - Hardcopy Received FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.g_df Standard Year TAS 125 2003 UL1897 2012 UL 580 2006 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 08/18/2017 08/25/2017 08/28/2017 10/10/2017 FL # I Model, Number or Name Description 17022.1 --[i - "5V Crimp" (116) 26 Gauge steel, 3/8" rib height,.24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf assembly in compliance with the installation method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.2 12 - "5V Crimp" (116) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions.Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Installation Instructions FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.p_df Created by Independent Third Party: Yes 17022.3 3 - "1.5" Mechanical Seam" (R5) 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.3 1.5 MECHANICAL Approved for use outside HVHZ: Yes seam 24aa ssr.pdf Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use. Install the assembly in compliance with the FL17022 R7 AE FL 17022.3 1.5 MECHANICAL installation method listed in this report and applicable code seam 24aa ssr.pdf sections of FBC. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions. 17022.4 I4 - "1.5" Mechanical Seam" (R5) 11.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.4 MECHANCIAL SEAM Approved for use outside HVHZ: Yes ALUMINUM ssr.pdf Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use. Install the assembly in compliance with the FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM installation method listed in this report and applicable code ALUMINUM ssr.pdf sections of FBC. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions. 17022.5 5 - "i in. Nail Strip" (R5) 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.pdf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Q Compliant with Florida Building Code 2017 ('" ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications corrosion Keslstant Lompllani: row- aec. is Fastener 1(Method 1 Attachment): #9 x 1- 3/16" min. thru deck or 5/8" embedment i requirements) Fastener 2 (Method 2,3, & 4 Attachment): penetrate 3/16" min. thru deck or 5/8" em to meet requirements) Underlayment: To be compliant with FBC Slope: Shall be in compliance with FBC Sec. Palm City, FL 34990 'Hex -Washer Head wood screw* to penetrate wood plank. (*or sufficient length to meet x 1-1/2" Hex -Washer Head wood screw* to ment into wood plank. (*or sufficient length Chart 1507.1.1 ,Fastener attachment specifications above D 1 METHOD 2 METHOD 3 METHOD 4 F -93.5 PSF -101 PSF -228 PSF 16" O.C. 8" o.c. 6" o.c. E 12" o.c. 12" o.c. 12" o.c. MF #10 #20 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527 UL 580-06 & 1897-041 Test Report EM893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to test standr UL 1897-12 *Design pressure margin of safety 2.1 Locke Bowden, P.E. does not have, not will acquire a financi: under this evaluation. Locke Bowden, P.E. is not owned, operated, or controlled by report. 1 q I ' a c 4Y m {G+facturing or distributing products W.`compadjorn3b0faiturer, or distributing products under this S r Tt •i4�'G .3� 7 FL1702 ti 6V Crimp (26GA Steel), 24" Wiae-Roof Panel - Details 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. 15/ 2" or greater Plywood, or - Wood plank 147 12' 3d3" Nominal 12" Nominal 12" O.C. O.C. Fasten L9 x 1-1/2" Min, or #10 x 1-1/2" Min. per —fable "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Width Panel Refer to Table "A" for Spacing Along Panel Overlap Length Deck-15/32" or greater Plywood, or - Wood plank